INTECNA
DP 4 ELECTRO
ELECTROCOAGULATION COMPACT PLANT
INTECNA
BASIC PRINCIPLES
In electro-coagulation plant, process is realized by an electrolytic cell where anodes and cathodes are connected with a DC generator.
At the ANODE reaction is
Al (metal) ==== Al 3+ + 3 e-
At the CATHODE reaction is
2 H2O + 2 e- ===== H2 + 2 OH-
In aqueous environment,
Al3+ + 3 H2O ==== Al(OH)3 + 3H+
Total Reaction is
2Al(metal) + 6H2O + 2 OH- ==== 2 Al(OH)4- + 3 H2 (gas)
INTECNA
Aluminium Hydroxyls create a flocculation and on the flocks surface, all suspended material (Oil, fats, dyes, paints...) are quickly absorbed.
Hydrogen developing improves the floatation of suspended materials.
In the second part of flocculation tank, floating material is aggregated by special aqueous Polymer dispersion ( series HYCRAM ELECTRO) and flocks passes to filtration.
INTECNA
TYPICAL GENERATOR CHARACTERISTICS
FEEDINGPower 400 VA three phasesFrequency 50 – 60 HzPower absorbed 8,6 KWA
GENERATED DIRECT CURRENT (DC)Current 300 APotential 24 VPower (theory) 8,6 KWARegulation 0-100 %
INTECNA
TYPICAL ELECTRODES ASSEMBLY
INTECNA
Retention time in electrolytic cell is regulated by calibrating starting process by our Technical Service.Substantially, retention time is connected with Aluminium Hydroxyls formation.Such parameter is regulated by Faraday’s Law m = 1/95600 * A / V * I *tWhere m = mass in grams of Aluminium dissolved A = Atomic Mass of Aluminium ( 27)V = Valence of Aluminium ( 3)I = Current (Amperes)t = time in second By our proprietary software we can evaluate the connections between : Flow-rate of wastewaterRetention time in electrolytic cellAluminium dissolvedEquivalent to Aluminium Hydroxyls compounds