2
Disclaimer Any of following circumstances, will not be our warrant: 1.Install the product without following the wiring diagram in this manual and cause the product damage. 2.Damaged by human reason (like product is soaked in water) or caused by not following the manual instructions. 3.Install or use the product without following the local laws and regulations. 4.Cover the warrant logo personally, or the client /the third party tries to maintain, repair, change the product and cause the damage. 5.Use of the environment does not meet the provisions of this manual. 6.Damaged by force majeure, like abnormal voltage, earthquake, flood, fire, thunderstroke, transpor tation accidents, etc. 7.Man-made damage during carrying, transportation. 8.Damaged by unstable match from other companys’ (not Relighting’s) poor design or defective quality products.(like luminaire). 9.Use the wrong input voltage, not 240V. 10.Beyond the warranty period Warning:Before installing the lamp, make sure the both conducting wires structured well, not bending or spreading separately. For Technical support, please email us at [email protected] or call us at (866) 558-2976 DENOVA1000KIT DOUBLE ENDED SERIES [240V] 1000W HPS COMPLETE 3-MODE ADJUSTABLE FIXTURE Insert lamp ends into VS lamp holder (A). Make sure that it has been properly locked in place by sliding VS lamp holder towards the middle of the fixture(B) This prevents the lamp from falling out. NOTE:These lamps have a quartz jacket.Fingerprints and oils must be wiped off prior to operration

DOUBLE ENDED SERIES [222444000VVV] 1000W HPS COMPLETE 3-MODE ADJUSTABLE FIXTURE · 2016. 11. 29. · 3-Mode Adjustable Fixture.Each ballast uses a high temperature, resin-sealed component

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DOUBLE ENDED SERIES [222444000VVV] 1000W HPS COMPLETE 3-MODE ADJUSTABLE FIXTURE · 2016. 11. 29. · 3-Mode Adjustable Fixture.Each ballast uses a high temperature, resin-sealed component

DisclaimerAny of following circumstances, will not be our warrant:1.Install the product without following the wiring diagram in this manual and cause the product

damage.2.Damaged by human reason (like product is soaked in water) or caused by not following the manual

instructions.3.Install or use the product without following the local laws and regulations.4.Cover the warrant logo personally, or the client /the third party tries to maintain, repair, change the

product and cause the damage.5.Use of the environment does not meet the provisions of this manual.6.Damaged by force majeure, like abnormal voltage, earthquake, flood, fire, thunderstroke, transpor

tation accidents, etc.7.Man-made damage during carrying, transportation.8.Damaged by unstable match from other companys’ (not Relighting’s) poor design or defective quality

products.(like luminaire).9.Use the wrong input voltage, not 240V.10.Beyond the warranty period

Warning:Before installing the lamp, make sure the both conducting wires structured well, not bending or spreading separately.

For Technical support, please email us at [email protected] or call us at (866) 558-2976

DENOVA1000KIT

DOUBLE ENDED SERIES [222444000VVV] 1000W HPS COMPLETE 3-MODE ADJUSTABLE FIXTURE

Insert lamp ends into VS lamp holder (A).Make sure that it has been properly locked in place bysliding VS lamp holder towards the middle of the fixture(B)This prevents the lamp from falling out.

NOTE:These lamps have a quartz jacket.Fingerprints and oils must be wiped off prior to operration

Page 2: DOUBLE ENDED SERIES [222444000VVV] 1000W HPS COMPLETE 3-MODE ADJUSTABLE FIXTURE · 2016. 11. 29. · 3-Mode Adjustable Fixture.Each ballast uses a high temperature, resin-sealed component

. When input voltage is lower than required, the output power will reduce automatically to protect ballast.When input voltage is switched to 240V, the ballast’s power will go back to normal automatically

.

CONNECT BALLAST AS SHOWN BELOW:

Thank you for purchasing the all-new Double Ended Series (240V) 1000W HPS Complete3-Mode Adjustable Fixture.Each ballast uses a high temperature, resin-sealed component board for zero acoustic resonance. Combined with a high PAR value double-eneded HPS bulb and a high-efficiency aluminum reflector, the DE HPS Complete Fixture outperforms conventional Super HPS by up to 15%.

The Complete 3-Mode Adjustable Fixture is supplied with a 240V, 16AWG input cord. By utilizing a microprocessor, the ballast features a Soft-Start technology which is designed to increase lumen performance, prolong lamp service life, and allows multiple ballasts to be ignited at once via staggering fire sequence. The microprocessor precisely dampens the input wattage, and allows adjustments to the output power (Dimmer Switch) with Soft-Dimming Technology to increase lamp service life. Under SDT, power adjustments from 600W to the 1150W setting (approx. 115% of rated maximum power output) will exhibit a gradual change over a period of two minutes instead of a sudden change in lumens. This patented feature is different from conventional digital ballast, which features a single power dimming method that shortens lamp service life dramatically.

WARNING 600 750 1000 1150Dimming Knob

IMPORTANT WIRING & LAMP INFORMATION

FEATURES

SPECIFICTIONS

AVAILABLE WATTAGE SETTINGS

Some 240V outlets and control boxes may contain a 4th wire that is a neutral wire which will cause electronic ballasts to malfunction.The correct input should be 2 HOT WIRES and 1 GROUND WIRE.If you have an existing 240 volt circuit that does contain a neutral wire, the neutral wire should be safely capped.If installed with a lighting controller containing a neutral wire, you must completely disconnect the neutral wire from the circuit.Generator ready and flip-board ready: up to a 4 minute delay when switching from one lamp to the next. Ballast must be powered down prior to the light flip. The Soft-Dimming Technology (SDT) gradually changes the lumen output of the lamp over a period of up to two minutes. This may appear as if the dimmer is defective; Highly recommend the use of a photometer to confirm the output.

End of Lamp Life (EOL) Protection Short Circuit Protection Open Circuit Protection Ignition Failure Protection Thermal Protection Soft-Start Technology (SST) Soft-Dimming Technology (SDT)

Max.allowable case temperature:75°C/167°F Ambient temperature:-20°C…+40°C/-4°F…+104°FMax.humidity:95%Ignition voltage is 5kV max. Max lamp cable:15m/50ft Voltage range 240V(+/-10%): 216-264V

240V SOCKET 120V SOCKET

240VOnly!

BEFORE USAGE, PLEASE TEAR OFF THE PROTECTIVE PLASTIC FILM LOCATED ON THE REFLECTOR.

INNOVATIVE DE SYSTEM 95% Reflective VEGA Aluminum 3-Mode Adjustable ReflectorVS Lamp Holder

Power surge, power outage, and overloading may stress or damage the lamp. As a safety feature, this Soft-Start technology also reduces ballast damage caused by a bulb failure. In case of an unexpected shut-off, please disconnect from the power supply, remove the faulty lamp, check for wiring problems, then plug-in the ballast power cord.. Working voltage should NOT be less than 200V.

. Ambient temperature should be under 400C .

. When ballast gets overheat, the output power will reduce automatically to protect ballast.

Warning:Only suitable for 240V power supply

When environment temperature deceases as lower than 400C , the ballast’s power will go back to normal automatically.