1/86Hydraulic Filtration 1
High Pressure Filters
www.buydonaldson.com
High Pressure Filters
High pressure filters are
positioned between pumps
and critical components
such as cylinders, motors
and valves. They help protect
these critical components
from catastrophic failure.
Donaldson heavy-duty high
pressure filters are rated
for working pressures up to
6500 psi (44818 kPa). Various
porting sizes and types,
including manifold style, are
available for a wide range
of applications.
Section Index
Max Operating Pressure < 6500 psi (450 bar)
Models arranged from low to maximum flow rates
In-line Cartridge Filters
W331 .......................................................128
HPK02......................................................132
W341 .......................................................138
W440 .......................................................142
FPK02 ......................................................146
W613 .......................................................152
W322 .......................................................156
W350 .......................................................160
HPK03......................................................164
W610 .......................................................170
FPK04 ...................................................... 174
HPK04......................................................180
W621 .......................................................188
W451 .......................................................193
W620 .......................................................197
WS620 .................................................... 202
HPK05..................................................... 207
8/13/2019 donaldson visokotlani filteri
2/86128 Hydraulic Filtration www.buydonaldson.com
W331Max Flow: 6 gpm (23 lpm)
W331 In-Line Cartridge Filters
Working Pressures to: 3000 psi21,000 kPa210 bar
Rated Static Burst to: 7500 psi51,700 kPa517 bar
Fatigue Pressure Rating: 1500 psi10,000 kPa100 bar
Flow Range to: 6 gpm23 lpm
The W331 in line filter assembly offers all aluminum construction with a positive sealing poppet type bypass for
reliability and zero leakage. Donaldson DT high-performance 4-layer media is offered in five different media grades.
The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal
lockout and surge control are two key features incorporated in many of the differential pressure indicators.
Aluminum head and housing
Compact design for use with servo or proportional valve
Positive sealing poppet for zero leakage
Beta Rating Performance to 5(c)=1000
Porting Size Options SAE-8 O-ring
Assembly Weight 4.25 lbs / 1.9 kg
Replacement Filter Lengths 3.44" / 87.3mm
Standard Bypass Ratings 50 psi / 345 kPa / 3.5 bar No Bypass
Operating Temperatures -45 to 250F (-43 to 121C)
Filter Collapse Ratings 150 psi / 1034 kPa / 10.3 bar (standard) 3000 psi / 20,700 kPa / 206.8 bar (high collapse)
Features
8/13/2019 donaldson visokotlani filteri
3/86Hydraulic Filtration 1www.buydonaldson.com
W331Max Flow: 6 gpm (23 lpm)
Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.
Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.
Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
I
92.08
(3.63)
76.20
(3.00)
38.10
(1.50)
IN OUT
P Indicator
Access Plug for Bypass Valve
(SAE-6 Socket Plug)
175.51
(6.91)Max
124.71
(4.91)
Max
19.05
(.75)
Inlet Port
6.75 (17/64) Thru.
2 Plcs.
56.64
(2.23)
76.20
(3.00)
19.05
(.75)
Square
69.85 (2.75) Require
for Element & Bowl
Removal
Torque Bowl to
20 N.M. (15 lbs-ft) Max.
Outlet Port
4.06
(.16)
Indicator
38.10 (1.50) Max. Visual
49.53 (1.95) Max Electrical
Head - Top View
Assembly - Side View
W331 Specification Illustrations
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches]. Applications
High Pressure Circuits In-Plant Systems
8/13/2019 donaldson visokotlani filteri
4/86130 Hydraulic Filtration www.buydonaldson.com
W331Max Flow: 6 gpm (23 lpm)
High-Performance DT Filter Choices
W331 Components
Performance DataW331 Housing Only
W331 Filter Only W331 High Collapse Filter Only
Flow Rate (gpm)
PressureD
rop
(psid)
PressureD
rop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
W331 Bypass Valve
0 2 4 640
45
50
55
60
50 PSID cracking
0
10
20
30
40
50
60
0 5 10 15 20
0
2
4
6
8
10
0 1 2 3 4 5 6
5m
8m
12m
0
10
20
30
40
50
60
0 5 10 15 20
0
2
4
6
8
10
0 1 2 3 4 5 6
P
ressureD
rop
(kPa)
Flow Rate (lpm)
Pre
ssureD
rop
(psid)
Flow Rate (gpm)
0
10
20
30
40
50
60
0 5 10 15 20
0
2
4
6
8
10
0 1 2 3 4 5 6
PressureDrop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
5m
14m
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
DT Synteq Synthetic 5 m 3.44 87.3 P572298 AN6235-3A
8 m 3.44 87.3 P572299 AN6235-3A
12 m 3.44 87.3 P572300 AN6235-3A
5 m 3.44 87.3 P572301 AN6235-3A, High collapse
12 m 3.44 87.3 P572302 AN6235-3A, High collapse
Filter Notes All Donaldson W331 filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson W331 filters are potted with epoxy-based adhesives.
Standard collapse W331 designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson W331 filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.
8/13/2019 donaldson visokotlani filteri
5/86Hydraulic Filtration 1www.buydonaldson.com
W331Max Flow: 6 gpm (23 lpm)
Housing Ordering Guide
Table 5 (Primary)
Indicator Style and Setting
CODE DP INDICATOR STYLE & SETTING
D Electrical/visual 35 psid
E Electrical/visual 100 psid
G Electrical/visual 35 psid w/TL
J P indicator plug
L Visual indicator 35 psid M Visual indicator 35 psid
w/ TL and surge
N Electrical/visual 35 psid
w/12" 3 wire flying lead
O Visual indicator 100 psid
P Visual indicator 100 psid
w/ TL and surge
R Electrical switch 35 psid
S Electrical/visual 100 psid
w/12" 3 wire flying lead
T Electrical switch 100 psid
W Electrical/visual 100 psid
w/TL
Y Electrical/visual 35 psid
w/TL and surge
Z Electrical/visual 100 psid
w/TL and surge
TL (thermal lockout)
Table 1
Filter Assembly
CODE DESCRIPTION
W331 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION
1 150 psid for housing
w/bypass valve
4 3000 psi for housing
w/o bypass valve
Table 3
Port Size Options
CODE PORT SIZE
O SAE-8 O-ring
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
4 50 psid
Note: Use option 1 code only with3000 psid collapse filter.
W331 1 O 4 L N B
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6
Metric Porting Available
Change W331 to G331
Porting code O becomes 1/2"ISO 228 BSPP
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Table 6
Seal Options
CODE MATERIAL
B Buna-N
V Viton
Filter
Assembly
Service
FilterFilters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Media Ratings
Western Filter elements have been replaced by
Donaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
03 5m DT Synteq Synthetic
05 8m DT Synteq Synthetic
10 12m DT Synteq Synthetic
For a complete filter interchange, visit
crossreference.donaldson.com.
METRIC PORTING AVAILABLE
Brad Harrison is a registered trademark of Woodhead Industries, Inc.
Hirschmann is a registered trademark of Richa rd Hirschmann of America Inc.
Buna-Nand Vitonare registered trademarks of E. I. DuPont de Nemours an
8/13/2019 donaldson visokotlani filteri
6/86132 Hydraulic Filtration www.buydonaldson.com
Working Pressures to: 2000 psi13,790 kPa
137.9 bar
Rated Static Burst to: 4500 psi 31,030 kPa 310.3 bar
Flow Range to: 20 gpm 75 lpm
HPK02 In-Line Cartridge Filters
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
7/86Hydraulic Filtration 1www.buydonaldson.com
Head - Top ViewAssembly - Side View
HPK02Max Flow: 20 gpm (75 lpm)
HPK02 Specification Illustrations
All dimensions are shown in inches [millimeters].
HPK02with Visual Service Indicator
HPK02with AC/DC Electrical Service Indicator
Applications
High Pressure Circuits In-Plant Systems
Meets HF2 Specification
Mobile Equipment Power Steering Circuits
Servo Valve Circuits
8/13/2019 donaldson visokotlani filteri
8/86134 Hydraulic Filtration www.buydonaldson.com
HPK02 Components
HPK02Max Flow: 20 gpm (75 lpm)
High-Performance DT Filter Choices
Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirtcapacity. High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.
Standard Filter Choices
Filter Notes* Utilizes DT Synteq synthetic media Refer to the table in the Technical Reference Guide for fluid compatibility with our filter media.
If filtering petroleum-based oil, filters with seals made of Buna-Nare appropriate for most applications.
If filtering diester, phosphate ester fluids, water glycol, water/oil emulsions, or HWCF over 150F/83C,use filters with seals made of fluorocarbon, such as Viton.
Donaldson "high collapse" filters, with their steel end caps and wire-backed media, are rated towithstand up to 3000 psi/ 20,700 kPa before collapsing.
The fluorocarbon seal/high collapse filters also use epoxy potting and media seam seals for addedchemical compatibility.
Some part numbers are offered with the same beta ratings to maintain customer ordering patterns.
VitonandBuna-Nregistered trademarks of E. I. DuPont de Nemours and Company.
Media x(c) = 1000 Length Donaldson CommentsType Rating based on ISO 16889 in mm Part No.
Synteq Synthetic 5 m 4.37 111 P167180* Fluorocarbon Seal, High Collapse
5 m 8.12 203 P167182* Fluorocarbon Seal, High Collapse
7 m 4.37 111 P169429 Buna-NSeal
7 m 4.37 111 P165041 Buna-N Seal
7 m 8.12 203 P167838 Buna-N Seal
7 m 8.12 203 P165043 Buna-N Seal
9 m 4.37 111 P165006 Buna-N Seal
9 m 8.12 203 P165015 Buna-N Seal
12 m 4.37 111 P167181* Fluorocarbon Seal, High Collapse12 m 8.12 203 P167183* Fluorocarbon Seal, High Collapse
23 m 4.37 111 P165136 Buna-N Seal
23 m 8.12 203 P165138 Buna-N Seal
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
DT Synteq Synthetic
8/13/2019 donaldson visokotlani filteri
9/86Hydraulic Filtration 1www.buydonaldson.com
Housing Choices
Length Part No.
short P167443
long P167452
Port Size Bypass Rating Indicators1 Part No.
Head Choices
SAE-12 O-Ring 50 psi/3.5 bar Visual indicator, left side P167728
SAE-12 O-Ring No bypass Visual indicator, left side P167730
Notes on Indicators1
Donaldson uses the inlet port as the reference point. "Left side," for instance, means that the indicator mounts on theside of the filter head that is on your left when you face the inlet port.
Replacement Indicator Only
Indicator Choices
Part No. Description
P567458Visual/Electrical indicator with thermal lockoutand surge, 35 psid/2.4 bar
P567459
Visual/Electrical indicator, with thermal lockout
and surge 70 psid/4.8 bar
P567456Pop-Up Visual Indicator, with thermal lockoutand surge 35 psid/2.4 bar
P567457Pop-Up Visual Indicator, with thermal lockoutand surge 70 psid/4.8 bar
P569636 Pop-Up Visual Indicator, 35 psid/2.4 bar
P569637 Pop-Up Visual Indicator, 70 psid/4.8 bar
P569638 Visual/Electrical Indicator, 35 psid/2.4 bar
P569639 Visual/Electrical Indicator, 70 psid/4.8 bar
P164315 Visual Indicator, bar style, 35 psid/2.4 bar
P166603 Visual Indicator, bar style, 70 psid/4.8 bar
P166134 Blanking plate
HPK02Max Flow: 20 gpm (75 lpm)
Indicator Mounting Block
Part No. Description
P573495 Mounting Block Assembly
Part No.
Use withBypass ValvePressure of: Description
P569634 50 psi / 3.5 bar
35 psi/2.4 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps
P569635 90 psi / 6.2 bar
70 psi/4.8 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps
P567986 50 psi / 3.5 bar
35 psi/2.4 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650
P567987 90 psi / 6.2 bar
70 psi/4.8 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650
Part No.
Use withBypass ValvePressure of: Description
P569632 50 psi / 3.5 bar35 psi/2.4 bar indicator kitauto reset pop-out button
P569633 90 psi / 6.2 bar70 psi/4.8 bar indicator kitauto reset pop-out button
P567988 50 psi / 3.5 bar
35 psi/2.4 bar indicator kitauto reset pop-out button withthermal lockout and surge control
P567989 90 psi / 6.2 bar
70 psi/4.8 bar indicator kit*auto reset pop-out button withthermal lockout and surge control
AC/DC Visual/Electrical Service Indicators
All kits include indicator with mounting block
Visual Service Indicators
Service Indicator Kits
8/13/2019 donaldson visokotlani filteri
10/86136 Hydraulic Filtration www.buydonaldson.com
Performance Data
HPK02Max Flow: 20 gpm (75 lpm)
HPK02 Housing Only
0
3
6
9
12
15
0 5 10 15 20 250
20
40
60
80
100
0 20 40 60 80
SAE-12
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
HPK02 Standard 8" Filter Only
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
HPK02 Standard 4" Filter Only
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
8/13/2019 donaldson visokotlani filteri
11/86Hydraulic Filtration 1www.buydonaldson.com
HPK02 Service Parts
Optional MountingBlock Assembly
P573495(Optional Position)
Replacement FilterSee Filter Choice Tables
HousingSee Housing AssemblyChoice Table
Pop Up VisualIndicator
See Option Table(Includes Indicator
O-Ring P161315Fluorocarbon,
Mounting Block& Hardware)
Electrical /Visual Indicator
See Option Table(Includes Indicator
O-Ring P161315Fluorocarbon,
Mounting Block& Hardware)
Blanking Plate P166134Includes O-Ring P161315
Fluorocarbon & Hardware)
SealP167268 Fluorocarbon
Visual Service Indicator
(Includes O-ring P161315Fluorocarbon & Hardware)Max Temp 180F (82C) / 345 kPaP164315 Normal Flow Model
O-Ring(Size 006)P161315 Fluorocarbon
O-Ring(Size 006)
P161315 Fluorocarbon
O-Ring(Size 006)
P161315 Fluorocarbon
Head AssembliesSee Head AssemblyOptions Table
Optional MountingBlock Assembly
P573495(Primary Position)
Pop Up VisualIndicator
See Option Table(Includes Indicator
O-Ring P161315Fluorocarbon,
Mounting Block& Hardware)
Electrical /Visual Indicator
See Option Table(Includes Indicator
O-Ring P161315Fluorocarbon,
Mounting Block& Hardware)
HPK02Max Flow: 20 gpm (75 lpm)
8/13/2019 donaldson visokotlani filteri
12/86138 Hydraulic Filtration www.buydonaldson.com
W341Max Flow: 20 gpm (75 lpm)
W341 In-Line Cartridge Filters
Working Pressures to: 3000 psi20,700 kPa207 bar
Rated Static Burst to: 7,500 psi51,700 kPa517 bar
Fatigue Pressure Rating: 1500 psi10,300 kPa103 bar
Flow Range to: 20 gpm75 lpm
Beta Rating Performance to 5(c)=1000
Porting Size Options SAE-12 O-ring
Assembly Weight 7.28": 5.3 lbs / 2.4 kg 10.03": 5.7 lbs / 2.6 kg
Replacement Filter Lengths 5.27" / 133.8mm 8.00" / 203.2mm
Standard Bypass Ratings 50 psi / 345 kPa / 3.5 bar No Bypass
Operating Temperatures -45 to 250F (-43 to 121C)
Filter Collapse Ratings 150 psi / 1034 kPa / 10.3 bar (standard) 3000 psi / 20,700 kPa / 206.8 bar (high collapse)
The W341 in line filter assembly offers all aluminum construction with a positive sealing poppet type bypass for
reliability and zero leakage. Donaldson DT high-performance 4-layer media is offered in four different media grades.
The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal
lockout and surge control are two key features incorporated in many of the differential pressure indicators.
Aluminum head and housing
Compact design for use with servo or proportional valve
Positive sealing poppet for zero leakage
Features
8/13/2019 donaldson visokotlani filteri
13/86Hydraulic Filtration 1www.buydonaldson.com
W341Max Flow: 20 gpm (75 lpm)
Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.
Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.
Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
W341 Specification Illustrations
Head - Top View
Assembly - Side View
Inlet Port
54.9(2.16)
Outlet Port
63.5 (2.50) Min. RequiredFor Bowl and Element
Removal
Refer to Model Code(Assembly Length)
63.5(2.50)
IN OUT
V isual- 38.1 Max. (1.50)Electrical- 49.53 Max. (1.95)
P Indicator
.250-20UNC-2B ThdX 12.7 (.50) Min. Thd Depth2 Plcs
101.6(4.00)
19.1(.75)
76.2(3.00)
30.2(1.19)
24.4(.96)
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches].
Refer to Filter Choices(Assembly Length)
Applications
High Pressure Circuits In-Plant Systems
8/13/2019 donaldson visokotlani filteri
14/86140 Hydraulic Filtration www.buydonaldson.com
W341Max Flow: 20 gpm (75 lpm)
High-Performance DT Filter ChoicesW341 Components
Filter Notes
All Donaldson DT filters utilize glass fiber mediawith an epoxy-based resin system for theultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh formaximum pleat support and dirt capacity.
High collapse designs are double wire-backedusing stainless steel mesh.
High collapse designs are also potted intomachined aluminum endcaps for greater filter
integrity in critical applications. Vitonseals are standard on all Donaldson DT
filters. Vitonis a registered trademark of E. I.DuPont de Nemours and Company.
Performance Data
W341 Housing Only
Flow Rate (gpm)
Pressure
Drop(psid)
W341 Bypass Valve
0 4 8 12 16 20
40
45
50
55
60
W341 8" Filter OnlyDT-N, 7.81"/198.3mm
W341 5" High Collapse Filter OnlyDT-N-HC, 5.06"/128.6mm
W341 8" High Collapse Filter OnlyDT-N-HC, 7.81"/198.3mm
0
10
20
30
40
50
60
0 20 40 60
0
2
4
6
8
10
0 5 10 15 20
PressureD
rop(kPa)
Flow Rate (lpm)
PressureD
rop(psid)
Flow Rate (gpm)
W341 5" Filter OnlyDT-N, 5.06"/128.6mm
0
10
20
30
40
50
60
0 10 20 30
2
4
6
8
10
00
2 4 6 8 10
PressureD
rop(k
Pa)
Flow Rate (lpm)
PressureD
rop
(p
sid)
Flow Rate (gpm)
5m
8m
14m
25m
0
10
20
30
40
50
60
0 20 40 60
0
2
4
6
8
10
0 5 10 15 20
PressureD
rop
(kP
a)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
5m8m
14m
25m
0
10
20
30
40
50
60
0 10
20 30
0
2
4
6
8
10
0 2 4
6 8 10
PressureD
rop
(kP
a)
Flow Rate (lpm)
PressureD
ro
p
(psid)
Flow Rate (gpm)
5m
14m
0
10
20
30
40
50
60
0 20 40 60
0
2
4
6
8
10
0 5 10 15 20
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
5m14m
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
DT Synteq Synthetic 5 m 5.27 133.8 P567065 DT-N-1-5UM
8 m 5.27 133.8 P567066 DT-N-1-8UM
12 m 5.27 133.8 P567067 DT-N-1-14UM
23 m 5.27 133.8 P567068 DT-N-1-25UM
5 m 8.00 203.2 P567069 DT-N-2-5UM
8 m 8.00 203.2 P567070 DT-N-2-8UM
12 m 8.00 203.2 P567071 DT-N-2-14UM
23 m 8.00 203.2 P567072 DT-N-2-25UM
5 m 5.27 133.8 P572303 DT-N-HC-1-5UM, High collapse
12 m 5.27 133.8 P572304 DT-N-HC-1-14UM, High collapse
5 m 8.00 203.2 P572305 DT-N-HC-2-5UM, High collapse
12 m 8.00 203.2 P572306 DT-N-HC-2-14UM, High collapse
8/13/2019 donaldson visokotlani filteri
15/86Hydraulic Filtration 1www.buydonaldson.com
W341Max Flow: 20 gpm (75 lpm)
Housing Ordering Guide
Table 5 (Primary)
Indicator Style and Setting
CODE DP INDICATOR STYLE & SETTING
D Electrical/visual 35 + 5 psid
E Electrical/visual 100 + 12 psid
G Electrical/visual 35 + 5 psid
w/TL
J No indicator L Visual indicator 35 + 5 psid
M Visual indicator 35 + 5 psid
w/ TL and surge
N Electrical/visual 35 + 5 psid
w/12" 3 wire flying lead
O Visual indicator 100 + 12 psid
P Visual indicator 100 + 12 psid
w/ TL and surge
R Electrical switch 35 + 5 psid
S Electrical/visual 100 + 12 psid
w/12" 3 wire flying lead
T Electrical switch 100 + 12 psid
W Electrical/visual 100 + 12 psid
w/TL
Y Electrical/visual 35 + 5 psid
w/TL and surge
Z Electrical/visual 100 + 12 psid
TL (thermal lockout)
Table 1
Filter Assembly
CODE DESCRIPTION
W341 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION
1 150 psid for housing
w/bypass valve
4 3000 psid for housing
without bypass valve
Table 3
Port Size Options
CODE PORT SIZE
A SAE-12 O-ring
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
4 50 psid
Table 7
Assembly & Filter Length
CODE (LGTH) FILTER LENGTH
1 (7.28") 5.3"2 (10.03") 8.0"
W341 1 A 1 M N B 1
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7
Metric Porting Available
Change W341 to G341
Porting code A becomes G-3/4"
ISO 228 BSPP
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Table 6
Seal Options
CODE MATERIAL
B Buna-N
V Viton
Filter
Assembly
Service
FilterFilters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Brad Harrison is a registered trademark of Woodhead Industries, Inc.
Hirschmann is a registered trademark of Richa rd Hirschmann of America Inc.
Buna-Nand Vitonare registered trademarks of E. I. DuPont de Nemours an
Media Ratings
Western Filter elements have been replaced by
Donaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
03 5m DT Synteq Synthetic
05 8m DT Synteq Synthetic
10 12m DT Synteq Synthetic
20 23m DT Synteq Synthetic
For a complete filter interchange, visit
crossreference.donaldson.com.
METRIC PORTING AVAILABLE
8/13/2019 donaldson visokotlani filteri
16/86142 Hydraulic Filtration www.buydonaldson.com
W440 In-Line Cartridge Filters
Working Pressures to: 4000 psi27,600 kPa276 bar
Rated Static Burst to: 10,000 psi69,000 kPa690 bar
Fatigue Pressure Rating: 2450 psi16,900 kPa169 bar
Flow Range to: 20 gpm75 lpm
The W440 filter assembly can be manifold mounted to the hydraulic system. The size and material configuration
are well-suited for todays demanding proportional and servo valve applications. Our standard housing drain plug
helps relieve system pressure during filter change-outs. DT 4-layer media is offered in a variety of designs. Five
different media grades are offered. Donaldson filters core collapse options range from 150 to 3,000 psi. The
differential pressure indicator line is designed to work with a wide assortment of bypass valves. Thermal lockout
and surge control are two key features incorporated in many of the differential pressure indicators.
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
17/86Hydraulic Filtration 1www.buydonaldson.com
Manifold Mounting
Bypass Valve
(Subplate Only)
Inlet and Outlet PortO-rings (-117) supplied
101.60
(4.00)
50.80(2.00)
81.28
(3.20)
46.23
(1.82)
17.02
(.67)
31.75
(1.25)
Drill 8.89 (.350) Hole Thru
25.40 (1.00) C'Bore
17.53 (.69) Hole
4 Plcs.
110.74
(4.36)
44.45
(1.75)
31.75
(1.25)
88.90
(3.50)
104.65
(4.12)
52.32
(2.06)
15.75
(.62)
Visual-86.61 Max.(3.41)
Elec.-98.04 Max.
(3.86)
P Indicator
2 Plcs
INLET
OUTLET
Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.
Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.
Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
Dimensions: millimeters/(inches)
W440Max Flow: 20 gpm (75 lpm)
W440 Specification Illustrations
Head - Top View
Assembly - Side View
6.73 (.265) Drill Hole Thru.
Mounting Holes, 2 Plcs.
Required ForElement and
63.50(2.50) Min.
Drain Plug
9/16-18UNF
Thread
SAE-6 Straight
69.34 (2.73)
Inlet Port
79.37
(3.125)
P Indicator
25.40
(1.00)
Visual-92.71 Max.
(3.65)
Electrical-104.14 Max.
(4.10)
Refer To
Model Code
(Assembly Length)
Torque Bowl To
20 N.M(15 Lbs-Ft)Max
O utlet
Port
Bowl Removal.
IN
OUT
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches].
Refer to Filter Choices(Assembly Length)
8/13/2019 donaldson visokotlani filteri
18/86144 Hydraulic Filtration www.buydonaldson.com
Performance Data
W440Max Flow: 20 gpm (75 lpm)
High-Performance DT Filter Choices
Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademarks of E. I. DuPont de Nemours and Company.
W440 Components
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
W440 4" DT Filter OnlyDT-9020-4, 4.41"/111.9mm
W440 8" DT Filter OnlyDT-9020-8, 8.28"/210.3mm
W440 4" DT Filter OnlyDT-9021-4, 4.46"/113.2mm
W440 8" DT Filter OnlyDT-9021-8, 8.16"/207.2mm
8/13/2019 donaldson visokotlani filteri
19/86Hydraulic Filtration 1www.buydonaldson.com
Housing Ordering Guide
Table 5 (Primary)
Indicator Style and Setting
CODE DP INDICATOR STYLE & SETTING
A Visual indicator 70 psid w/TL & surge
B Electrical/visual 70 psid
w/TL and surge
D Electrical/visual 35 psid
E Electrical/visual 100 psid G Electrical/visual 35 psid w/TL
I Visual indicator 70 psid
J DP indicator plug
L Visual indicator 35 psid
M Visual indicator 35 psid
w/ TL and surge
N Electrical/visual 35 psid
w/12" 3-wire flying lead
O Visual indicator 100 psid
P Visual indicator 100 psid
w/TL and surge
R Electrical switch 35 psid
S Electrical/visual 100 psid
w/12" 3-wire flying lead
T Electrical switch 100 psid
U Electrical switch 70 psid
W Electrical/visual 100 psid w/TL
Y Electrical/visual 35 psid
w/TL and surge
Z Electrical/visual 100 psid
w/TL and surge
TL (thermal lockout)
Table 1
Filter Assembly
CODE DESCRIPTION
W440 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION
1 150 psid for housing
w/bypass valve
4 3000 psi for housing
w/o bypass valve
Table 3
Port Size Options
CODE PORT SIZE
A SAE-12 O-ring
S Manifold mounting
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
4 50 psid
6 90 psid
Note: Use option 1 code only with3000 psid collapse filter.
Table 7
Assembly & Filter Length
CODE (LGTH) FILTER LENGTH 1 (7.18") 4.4"
2 (10.8") 8.2"*
*HF2
W440 1 S 1 J N B 1
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7
Metric Porting Available
Change W440 to G440
Porting code A becomes G-3/4"ISO 228 BSPP
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Filter
Assembly
Service
Filter
W440Max Flow: 20 gpm (75 lpm)
Filters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Brad Harrison is a registered trademark of Woodhead Industries, Inc.
Hirschmann is a registered trademark of Richard Hirschmann of America Inc.
Buna-Nand Vitonare registered trademarks of E. I. DuPont de Nemours and Company.
Media Ratings
Western Filter elements have been replaced byDonaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
01
8/13/2019 donaldson visokotlani filteri
20/86146 Hydraulic Filtration www.buydonaldson.com
FPK02 In-Line Cartridge Filters
Standard Bypass Ratings 87 psi/ 600 kPa / 6 bar 87 psiBypass with reverse-flow
check valve No Bypass
Operating Temperatures -20F to 250F / -29C to 120C
Filter Collapse Ratings 290 psi/ 2000 kPa / 20 bar (standard) 3000 psi/ 20,700 kPa / 207 bar
(high collapse)
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
21/86Hydraulic Filtration 1www.buydonaldson.com
Indicator PlugRemove plug to
install visual or
electrical indicator.
46.0
94
3.7
42
83.4
M8 X 17 2X
.91
3.28
23.0
1.81
1.7
OUTLETINLET
4.47
113.5
Head - Top View
Head - Side View
M8 x1.25
x .55 Full THD
[14} 2-PLCS
All dimensions above are shown in inches [millimeters]
FPK02Max Flow: 25 gpm (95 lpm)
Assembly - Side View
90.0
332.5
13.09
HOUSING
HOUSING
231.5
9.11
1.61
41.0
3.54
Short Housing
Long Housing
FPK02 Specification Illustrations
All dimensions are shown in inches [millimeters]. Applications
High Pressure Circuits In-Plant Systems
Meets HF2 Specification Mobile Equipment Power Steering Circuits Servo Valve Circuits
8/13/2019 donaldson visokotlani filteri
22/86148 Hydraulic Filtration www.buydonaldson.com
FPK02 Components
NOTE:Indicator port is machined and plugged. Replace plug with indicatorof choice: P171945 (visual) or P761056 (electrical).
SAE-12 O-Ring 87 psi / 6 bar P762766
SAE-12 O-Ring 87 psi / 6 bar P762767
with reverse-flow
check valveSAE-12 O-Ring No Bypass P762768
Head ChoicesHead ChoicesPort Size Bypass Rating Part No.
Housing ChoicesLength Part(in.) No.
4.4" filter P762769
8.2" filter P762770
RFC
Reverse FlowCheck Schematic
FPK02Max Flow: 25 gpm (95 lpm)
High-Performance DT Filter Choices
Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT filters. Vitonis aregistered trademark of E. I. DuPont de Nemours and Company.
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
DT Synteq Synthetic
8/13/2019 donaldson visokotlani filteri
23/86Hydraulic Filtration 1www.buydonaldson.com
FPK02Max Flow: 25 gpm (95 lpm)
Filter Notes* Utilizes DT Synteq synthetic media Refer to the table in the Technical Reference Guide for fluid compatibility with our filter media.
If youre filtering petroleum-based oil, filters with seals made of Buna-N are appropriate for most applications.
If youre filtering diester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF over 150F/83C, usefilters with seals made of fluorocarbon, such as Vitonfrom DuPont Dow Elastomers, or Fluorelfrom 3M Company.
Donaldson "high collapse" filters, with their steel end caps and wire-backed media, are rated to withstand up to 3000psi/ 20,700 kPa before collapsing.
The fluorocarbon seal/high collapse filters also use epoxy potting and media seam seals for added chemicalcompatibility.
Some part numbers are offered with the same beta ratings to maintain customer ordering patterns.
VitonandBuna-Nregistered trademarks of E. I. DuPont de Nemours and Company.
Standard Filter Choices
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
Synteq Synthetic 5 m 4.37 111 P167180* Fluorocarbon Seal, High Collapse
5 m 8.12 203 P167182* Fluorocarbon Seal, High Collapse
7 m 4.37 111 P169429 Buna-NSeal
7 m 4.37 111 P165041 Buna-N Seal
7 m 8.12 203 P167838 Buna-N Seal
7 m 8.12 203 P165043 Buna-N Seal
9 m 4.37 111 P165006 Buna-N Seal
9 m 8.12 203 P165015 Buna-N Seal
12 m 4.37 111 P167181* Fluorocarbon Seal, High Collapse
12 m 8.12 203 P167183* Fluorocarbon Seal, High Collapse
23 m 4.37 111 P165136 Buna-N Seal
23 m 8.12 203 P165138 Buna-N Seal
8/13/2019 donaldson visokotlani filteri
24/86150 Hydraulic Filtration www.buydonaldson.com
Performance Data
FPK02Max Flow: 25 gpm (95 lpm)
FPK02 Standard 8" Filter Only8.12"/203mm
FPK02 Housing Only
FPK02 Standard 4" Filter Only4.37"/111mm
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
0
3
6
9
12
15
0 5 10 15 20 25
0
20
40
60
80
100
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
SAE-12
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
0
5
10
15
20
25
0 5 10 15 20 250
30
60
90
120
150
0 20 40 60 80
8/13/2019 donaldson visokotlani filteri
25/86Hydraulic Filtration 1www.buydonaldson.com
When installing the FPK02 housing onto an installed head, torque it to 15 ft-lbs./2.1 kg-m.
FPK02 Service Parts
FPK02Max Flow: 25 gpm (95 lpm)
- oil before assembling
Filter
Housing
Head
Plugremove only wheninstalling indicator.
AC/DC ElectricalIndicatorP761056
5 bar, 72.5 psid
Visual IndicatorP1719455 bar, 72.5 psid
O-Ring 2-140P173382Non-stock item
G 1/2"threads
SERVICE PARTS NOTE:Some service parts may not be stocked. Please contact yourDonaldson sales representative for lead time details.
Back-up RingP173380Non-stock item
8/13/2019 donaldson visokotlani filteri
26/86152 Hydraulic Filtration www.buydonaldson.com
W613Max Flow: 35 gpm (130 lpm)
W613 In-Line Cartridge Filters
Working Pressures to: 6500 psi44,800 kPa448 bar
Rated Static Burst to: 20,000 psi138,000 kPa1380 bar
Fatigue Pressure Rating: 3250 psi22,400 kPa224 bar
Flow Range to: 35 gpm130 lpm
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
27/86Hydraulic Filtration 1www.buydonaldson.com
W613Max Flow: 35 gpm (130 lpm)
Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.
Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.
Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
W613 Specification Illustrations
Head - Top View
Assembly - Side View
Outlet Port
33.27 Hex
(1.31)
Drain Plug9/16-18 UNF
SAE 6 Straight Thread
Refer to
Model Code
(Assembly Length)
Vi sual- 38.1 (1.50) Max.
Electrical- 49.53 (1.95) Max.
63.5 Min.
(2.50)Required For Bowl
and Element Removal
50.8
(2.00)
69.3
(2.73)
Inlet Port
P Indicator
l
i l . . .
l i l . . .
..
.
.
.
.
.
.
.
.
.
.
. i .
i l
l
l l
i
l
.
.
i l
i
l
l
i l . . .
l i l . . .
. i .
.
i l
l l
.
.
.
.
l
i
l
i l . . .
l i l . . .
57.2
(2.25)
28.4
(1.12)
94.5
(3.72)
47.2
(1.86)
139.7
(5.50)
97.0
(3.82)
7/16-14 UNC-2B Thd
.70 Min. Thd Depth
Mounting Hole
4 Plcs
Bleed Plug
7/16-20UNF
SAE-4 Straight Thread
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches].
Refer to Filter Choices(Assembly Length)
Applications
High Pressure Circuits In-Plant Systems
8/13/2019 donaldson visokotlani filteri
28/86154 Hydraulic Filtration www.buydonaldson.com
W613Max Flow: 35 gpm (130 lpm)
High-Performance DT Filter ChoicesW613 Components
Performance Data
Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademarks of E. I. DuPont de Nemours and Company.
W613 4" DT Filter OnlyDT-9800-4, 4"/102mm
W613 4" DT Filter OnlyDT-9801-4, 4"/102mm
W613 8" DT Filter OnlyDT-9801-8, 8"/203mm
W613 Housing Only
Flow Rate (gpm)
Pressure
Drop
(psid)
0
0
4
8
12
16
20
2010 30 40
SAE-12
SAE-16
1" Flg. Mt.
0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
0
20
40
40 50 60
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
Flow Rate (gpm)
0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
5m
8/13/2019 donaldson visokotlani filteri
29/86Hydraulic Filtration 1www.buydonaldson.com
W613Max Flow: 35 gpm (130 lpm)
Housing Ordering Guide
Table 1
Filter Assembly
CODE DESCRIPTION
W613 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION 1 150 psid for housing
w/bypass valve
4 3000 psid for housing
without bypass valve
Table 3
Port Size Options
CODE PORT SIZE
A SAE-12 O-ring
B SAE-16 O-ring
F 1" SAE 4-Bolt FlangeCode 61
M 1" SAE 4-Bolt Flange
Code 62
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
4 50 psid
6 90 psid
Table 7
Assembly & Filter Length
CODE (LGTH) FILTER LENGTH
1 (8.10") 4.4"
2 (11.75") 8.2"
W613 1 B 4 M N B 2
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7
Metric Porting Available
Change W613 to G613
Porting code A becomes 3/4"ISO 228 BSPP
Porting code B becomes 1"ISO 228 BSPP
Porting code F becomes 1" SAE 4 boltflange with M10 mounting threads
Porting code M becomes 1" SAE 4 boltflange with M12 mounting threads
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Table 6Seal Options
CODE MATERIAL
B Buna-N
V Viton
Table 5 (Primary)
Indicator Style and Setting
CODE DP INDICATOR STYLE & SETTING
A Visual indicator 70 + 10 psid
w/TL and surge
B Electrical/visual 70 + 10 psid
w/TL and surge
D Electrical/visual 35 + 5 psid
E Electrical/visual 100 + 12 psid
G Electrical/visual 35 + 5 psid w/TL
I Visual indicator 70 + 10 psid
J No indicator
L Visual indicator 35 + 5 psid
M Visual indicator 35 + 5 psid
w/ TL and surge
N Electrical/visual 35 + 5 psid
w/12" 3 wire flying lead
O Visual indicator 100 + 12 psid
P Visual indicator 100 + 12 psid
w/TL and surge
R Electrical switch 35 + 5 psid
S Electrical/visual 100 + 12 psid
w/12" 3 wire flying lead
T Electrical switch 100 + 12 psid
U Electrical switch 70 + 10 psid
V Electrical/visual 70 + 10 psid w/TL
W Electrical/visual 100 + 12 psid
w/TL
Y Electrical/visual 35 + 5 psid
w/TL and surge
Z Electrical/visual 100 + 12 psid
w/TL and surge
TL (thermal lockout)
Filter
Assembly
Service
FilterFilters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Media Ratings
Western Filter elements have been replaced by
Donaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
01
8/13/2019 donaldson visokotlani filteri
30/86156 Hydraulic Filtration www.buydonaldson.com
W322Max Flow: 50 gpm (190 lpm)
W322 In-Line Cartridge Filters
Working Pressures to: 3000 psi20,700 kPa207 bar
Rated Static Burst to: 7,500 psi51,700 kPa517 bar
Fatigue Pressure Rating: 2000 psi13,800 kPa138 bar
Flow Range to: 50 gpm190 lpm
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
31/86Hydraulic Filtration 1www.buydonaldson.com
W322Max Flow: 50 gpm (190 lpm)
Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.
Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.
Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
W322 Specification Illustrations
Head - Top View
Assembly - Side Views
73.15
(2.88)
SAE-12 Plug
SAE-24 Access Plug
(Ball Valve)
Outlet Check Valve
Typ 2 Plcs
69.85 Min.
(2.75)
Clearance to
Remove Element
and Bowl
97.54
(3.84)
164.34
(6.47)
Max
Torque Bowl to Head
20 N.M(15 Lbs-Ft)Max
Drain Plug
9/16-18UNF
(SAE-6 Plug)
152.40
(6.00)
P Indicator
292.61
(11.52)
Bleed Plug
7/16-20UNF
(SAE-4 Plug)
Inlet Port
(Outlet Port at
Opposite Side.)
Refer To
Model Code
(Assembly Length)
.
.
.
.
.
i l l
.
.
.
.
..
..
.
.
l l
l
.
.
i i i i
: l i i
.
.
l
l
ll l
l l
l
. i .
.
l
l
l
.
.
.
.
l
.
i l
l
.
.
i
.
.
l l
l
l
l
i i .
l
l
243.84
(9.60)
152.40
(6.00)
7/16-14UNC-2B Thd.
Mounting Holes, 4 Plcs
50.80
(2.00)
12.70
(.50)
218.40
(8.60)
12.70
(.50)
254.76
(10.03)
Alternate Outlet Port
(Plugged)
105.40
(4.15)
indicates flow direction
Note: Handle position
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches].
Refer to Filter Choices(Assembly Length)
Applications
High Pressure Circuits In-Plant Systems
8/13/2019 donaldson visokotlani filteri
32/86158 Hydraulic Filtration www.buydonaldson.com
W322Max Flow: 50 gpm (190 lpm)
High-Performance DT Filter ChoicesW322 Components
Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.
Performance DataW322 4" DT Filter Only
DT-9800-4, 4"/102mm
W322 4" DT Filter OnlyDT-9801-4, 4"/102mm
W322 8" DT Filter OnlyDT-9801-8, 8"/203mm
Flow Rate (gpm)
Pressure
Drop
(psid)
W322 Housing Only
0
0
10
20
30
40
2010 30 40 50 0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
5m
8/13/2019 donaldson visokotlani filteri
33/86Hydraulic Filtration 1www.buydonaldson.com
W322Max Flow: 50 gpm (190 lpm)
Housing Ordering Guide
Table 5 (Primary)
Indicator Style and Setting
CODE DP INDICATOR STYLE & SETTING
A Visual indicator 70 psid
w/TL and surge
B Electrical/visual 70 psid
w/TL and surge
D Electrical/visual 35 psid E Electrical/visual 100 psid
G Electrical/visual 35 psid w/TL
I Visual indicator 70 psid
J P indicator plug
L Visual indicator 35 psid
M Visual indicator 35 psid
w/TL and surge
N Electrical/visual 35 psid
w/12" 3-wire flying lead
O Visual indicator 100 psid
P Visual indicator 100 psid
w/TL and surge
R Electrical switch 35 psid
S Electrical/visual 100 psid
w/12" 3-wire flying lead
T Electrical switch 100 psid
U Electrical switch 70 psid
V Electrical/visual 70 psid w/TL
W Electrical/visual 100 psid w/TL
Y Electrical/visual 35 psid
w/TL and surge
Z Electrical/visual 100 psid
w/TL and surge
TL (thermal lockout)
Table 1
Filter Assembly
CODE DESCRIPTION
W322 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION
1 150 psid for housing
w/bypass valve
4 3000 psid for housing
without bypass valve
Table 3
Port Size Options
CODE PORT SIZE
B SAE-16 O-ring
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
4 50 psid
6 90 psid
Table 7
Assembly & Filter Length
CODE (LGTH) FILTER LENGTH
1 (6.88") 4.4"
2 (9.86") 8.2"
W322 1 B 4 D N B
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6
Metric Porting Available
Change W322 to G322
Porting code B becomes 1"
ISO 228 BSPP
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Table 6
Seal Options
CODE MATERIAL
B Buna-N
V Viton
*Note: Use option 1 code only with
3000 psid collapse filter.
2
TABLE 7
Filter
Assembly
Service
FilterFilters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Media Ratings
Western Filter elements have been replaced by
Donaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
01
8/13/2019 donaldson visokotlani filteri
34/86160 Hydraulic Filtration www.buydonaldson.com
W350 In-Line Cartridge Filters
Features
Working Pressures to: 3000 psi21,000 kPa210 bar
Rated Static Burst to: 7500 psi51,700 kPa517 bar
Fatigue Pressure Rating: 1500 psi10,000 kPa100 bar
Flow Range to: 50 gpm190 lpm
The W350 T-type ported series offers flows up to 50 gpm (190 lpm) with 3 bypass options and conforms to
the HF3 automotive standard. Our standard housing drain plug helps relieve system pressure during filter
changeouts. DT 4-layer media is offered in a variety of designs. Five different media grades are offered.
Donaldson filters core collapse options range from 150 to 3,000 psi (10 to 210 bar). The differential pressure
indicator line is designed to work with the wide assortment of bypass valves. Thermal lockout and surge
control are two key features incorporated in many of the differential pressure indicators.
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
35/86Hydraulic Filtration 1www.buydonaldson.com
Differential Indicators:Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure.
It is recommended that an indicator with a bypass setting of 100 psid is used with a non-
bypass housing.
Surge Control:This optional feature is used to dampen pressure surges or spikes to avoid premature
actuation of the indicator. Surge control delays the indicator response.
Thermal Lockout:The Thermal Lockout prevents premature signaling of a bypass condition created by viscous
fluid during cold start-ups. Normal indicator actuation capability is resumed once the
operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
W350Max Flow: 50 gpm (190 lpm)
W350 Specification Illustrations
Head - Top View
Assembly - Side View
123.19
4.85
26.92
1.06
130.30
5.13
HEX32.67
1.29
MAX.
34.80
1.37
VISUAL 54.10(2.3)MAX.
ELECT. 65.53(2.58)MAX.
P INDICATOR
BLEED PLUG
7/16-20UNFSAE-4 STRAIGHT THD
INLET PORT
TORQUE BOWL TO20 N.M. (15 LBS-FT) MAX
DRAIN PLUG9/16-18UNF
SAE 6 STRAIGHT THD
OUTLET PORT
REFER TOMODEL CODE
(ASSEMBLY LENGTH)
MIN
REQ'D FOR ELEMENTAND BOWL REMOVAL
50.80 2.00
5/16-18UNC-3B THD.
2X MOUNTING HOLES
57.15
2.25
28.58
1.12
63.50
2.50
31.89
1.26
33.53
1.32
34.92
1.38
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches].
Refer to Filter Choices(Assembly Length)
8/13/2019 donaldson visokotlani filteri
36/86162 Hydraulic Filtration www.buydonaldson.com
High-Performance DT Filter Choices
Filter Notes All Donaldson DT and DX2 filters utilize glass
fiber media with an epoxy-based resin systemfor the ultimate in chemical compatibility.
All Donaldson DT and DX2 filters are potted withepoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh formaximum pleat support and dirt capacity.
High collapse designs are double wire-backedusing stainless steel mesh.
High collapse designs are also potted intomachined aluminum endcaps for greater filterintegrity in critical applications.
Vitonseals are standard on all Donaldson DTand DX2 filters. Vitonis a registered trademarkof E. I. DuPont de Nemours and Company.
DX2 filters utilize nylon mesh for pleat support.
W350 Components
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
W350 Housing Only
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
0
5
10
15
20
25
0 10 20 30 40 50 600
20
40
60
80
100
120
140
160
0 50 100 150 200
0
5
10
15
20
25
0 10 20 30 40 50 600
20
40
60
80
100
120
140
160
0 50 100 150 200
0
5
10
15
20
25
0 20 40 60 80 1000
20
40
60
80
100
120
140
160
0 50 100 150 200 250 300 350
0
5
10
15
20
25
0 20 40 60 80 1000
20
40
60
80
100
120
140
160
0 50 100 150 200 250 300 350
0
5
10
15
20
25
0 10 20 30 40 500
20
40
60
80
100
120
140
160
0 50 100 150
5m
8/13/2019 donaldson visokotlani filteri
37/86Hydraulic Filtration 1www.buydonaldson.com
Table 1
Filter Assembly
CODE DESCRIPTION
W350 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION
1 150 psid for housing
w/bypass valve
4 3000 psi for housing
w/o bypass valve
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
3 25 psid
4 50 psid
6 90 psid
Note: Use option 1 code only with3000 psid collapse filter.
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Table 7
Assembly & Filter Length
CODE (LENGTH) FILTER LENGTH
1 (8.5") 4.0"
2 (12.0") 8.0"
Filter
Assembly
Service
Filter
W350 1 B 1 J N B 1
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7
Table 5 (Primary)
Indicator Style and Setting
CODE DP INDICATOR STYLE & SETTING
A Visual indicator 70 psid
w/TL & surge
B Electrical/visual 70 psid
w/TL and surge
C Electrical/visual 15 psid D Electrical/visual 35 psid
E Electrical/visual 100 psid
F Electrical/visual 15 psid w/TL
G Electrical/visual 35 psid w/TL
H Electrical/visual 15 psidw/12" 3-wire flying lead
I Visual indicator 70 psid
J P indicator plug K Visual indicator 15 psid
L Visual indicator 35 psid
M Visual indicator 35 psid
w/ TL and surge N Electrical/visual 35 psid
w/12" 3-wire flying lead
O Visual indicator 100 psid
P Visual indicator 100 psidw/TL and surge
Q Electrical switch 15 psid
R Electrical switch 35 psid
S Electrical/visual 100 psidw/12" 3-wire flying lead
T Electrical switch 100 psid
U Electrical switch 70 psid
W Electrical/visual 100 psid w/TL X Electrical/visual 15 psid
w/TL and surge
Y Electrical/visual 35 psidw/TL and surge
Z Electrical/visual 100 psidw/TL and surge
TL (thermal lockout)
Metric Porting Available
Change W350 to G350
Porting code B becomes G-1"ISO 228 BSPP
Table 3
Port Size Options
CODE PORT SIZE
A SAE-12 O-ring
B SAE-16 O-ring
Housing Ordering Guide
W350Max Flow: 50 gpm (190 lpm)
Filters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Media Ratings
Western Filter elements have been replaced by
Donaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
01
8/13/2019 donaldson visokotlani filteri
38/86164 Hydraulic Filtration www.buydonaldson.com
Standard Bypass Ratings 50 psi/ 345 kPa / 3.5 bar No Bypass
Operating Temperatures -20F to 250F / -29C to 121C
Filter Collapse Ratings 200 psi/ 1380 kPa / 13.8 bar (standard) 3000 psi/ 20,700 kPa / 206.9 bar
(high collapse)
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
39/86Hydraulic Filtration 1www.buydonaldson.com
Head - Top View
Assembly - Side View
HPK03Max Flow: 60 gpm (227 lpm)
HPK03 Specification Illustrations
All dimensions are shown in inches [millimeters].
HPK03with Visual Service Indicator
HPK03with AC/DC Electrical Service Indicator
Applications
High Pressure Circuits In-Plant Systems
Meets HF3 Specification Mobile Equipment Servo Valve Circuits
8/13/2019 donaldson visokotlani filteri
40/86166 Hydraulic Filtration www.buydonaldson.com
HPK03 Components
Filter Notes All Donaldson DT and DX2 filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT and DX2 filters are potted with epoxy-based adhesives. DX2 filters utilize nylon mesh for pleat support.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT and DX2 filters. Vitonis a registered trademark of E. I. DuPont de Nemours and Company.
HPK03Max Flow: 60 gpm (227 lpm)
Filter Notes* Utilizes DT Synteq synthetic media
SEALS: Filters with seals made of Buna-Nare appropriate for most applications involvingpetroleum oil. Filters with seals made of Viton(a fluoroelastomer) are required when usingdiester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF (high water contentfluids) over 150F/83C.
Refer to table in the Technical Reference Guide for fluid compatibility with our filter media.
Donaldson high collapse filters are physically designed to withstand up to 3000 psi / 20,700 kPabefore collapsing.
The Vitonhigh collapse filter versions also use epoxy potting and media seam seals for addedchemical compatibility.
Some part numbers are offered with the same beta ratings to maintain customer ordering patterns.
VitonandBuna-Nregistered trademarks of E. I. DuPont de Nemours and Company.
Standard Filter Choices
High-Performance DT Filter Choices
Media x(c) = 2 x(c) = 1000 Length Donaldson CommentsType Rating based on ISO 16889 in mm Part No.
Synteq Synthetic 5 m 8.22 208.8 P167185* Viton, High collapse for no bypass applications
7 m 8.22 208.8 P167842 Buna-N
7 m 8.22 208.8 P164594 Buna-N
9 m 8.22 208.8 P164166 Buna-N
12 m 8.22 208.8 P167186* Viton, High collapse for no bypass applications
23 m 8.22 208.8 P164174 Buna-N
50 m 8.22 208.8 P165319 Buna-N
Water
Absorbing 10 m 8.22 208.8 P569528
Wire Mesh 75 m 8.22 208.8 P162233
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
DT Synteq Synthetic
8/13/2019 donaldson visokotlani filteri
41/86Hydraulic Filtration 1www.buydonaldson.com
The P179579housing is 10.73 inches (273mm) long and accepts the filterthat is 8.22 inches (208.8mm) long. It includes a head-to-housing seal.
Port Size Bypass Rating Indicators1 Part No.
SAE-16 O-Ring 50 psi / 3.5 bar Visual indicator, left side P166353
SAE-12 O-Ring 50 psi / 3.5 bar Visual indicator, left side P170489
SAE-12 O-Ring No bypass Visual indicator, left side P170491
Head Choices
Notes1Donaldson uses the inlet port as the reference point. "Left side," for instance, means that the indicator
mounts on the side of the filter head that is on your left when you face the inlet port.
Housing ChoicesLength Part(in.) No.
8.22" filter P179579
HPK03Max Flow: 60 gpm (227 lpm)
Replacement Indicator Only
Part No.
Use withBypass ValvePressure of: Description
P569634 50 psi / 3.5 bar
35 psi/2.4 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps
P569635 90 psi / 6.2 bar
70 psi/4.8 bar indicator kitHirschmann receptacle115 VAC/28 VDC, 2 amps
P567986 50 psi / 3.5 bar
35 psi/2.4 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650
P567987 90 psi / 6.2 bar
70 psi/4.8 bar indicator kit withthermal lockout and surge control,Hirschmann receptacle, 115 VAC/28VDC, 2 amps, 4 pin DIN 43650
Part No.
Use withBypass ValvePressure of: Description
P569632 50 psi / 3.5 bar35 psi/2.4 bar indicator kitauto reset pop-out button
P569633 90 psi / 6.2 bar70 psi/4.8 bar indicator kitauto reset pop-out button
P567988 50 psi / 3.5 bar
35 psi/2.4 bar indicator kitauto reset pop-out button withthermal lockout and surge control
P567989 90 psi / 6.2 bar
70 psi/4.8 bar indicator kit*auto reset pop-out button withthermal lockout and surge control
AC/DC Visual/Electrical Service Indicators
All kits include indicator with mounting block
Visual Service Indicators
Service Indicator Kits Indicator Choices
Part No. Description
P567458Visual/Electrical indicator with thermal lockoutand surge, 35 psid/2.4 bar
P567459
Visual/Electrical indicator, with thermal lockout
and surge 70 psid/4.8 bar
P567456Pop-Up Visual Indicator, with thermal lockoutand surge 35 psid/2.4 bar
P567457Pop-Up Visual Indicator, with thermal lockoutand surge 70 psid/4.8 bar
P569636 Pop-Up Visual Indicator, 35 psid/2.4 bar
P569637 Pop-Up Visual Indicator, 70 psid/4.8 bar
P569638 Visual/Electrical Indicator, 35 psid/2.4 bar
P569639 Visual/Electrical Indicator, 70 psid/4.8 bar
P164315 Visual Indicator, bar style, 35 psid/2.4 bar
P166603 Visual Indicator, bar style, 70 psid/4.8 bar
P166134 Blanking plate
Indicator Mounting Block
Part No. Description
P573495 Mounting Block Assembly
8/13/2019 donaldson visokotlani filteri
42/86168 Hydraulic Filtration www.buydonaldson.com
Performance Data
HPK03Max Flow: 60 gpm (227 lpm)
HPK03 8" Standard Filter OnlyHPK03 Housing Only
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
0
3
6
9
12
15
0 12 24 36 48 600
20
40
60
80
100
0 50 100 150 200
SAE-12
SAE-16
0
4
8
12
16
20
0 12 24 36 48 600
30
60
90
120
0 50 100 150 200
0
5
10
15
20
25
0 20 40 60 80 1000
20
40
60
80
100
120
140
160
0 50 100 150 200 250 300 350
0
5
10
15
20
25
0 20 40 60 80 1000
20
40
60
80
100
120
140
160
0 50 100 150 200 250 300 350
0
5
10
15
20
25
0 10 20 30 40 500
20
40
60
80
100
120
140
160
0 50 100 150
WireMesh
5m8m
12m
23m
8/13/2019 donaldson visokotlani filteri
43/86
8/13/2019 donaldson visokotlani filteri
44/86170 Hydraulic Filtration www.buydonaldson.com
W610Max Flow: 50 gpm (189 lpm)
W610 In-Line Cartridge Filters
Working Pressures to: 6,000 psi41,368 kPa414 bar
Rated Static Burst to: 20,000 psi138,000 kPa1380 bar
Fatigue Pressure Rating: 3,500 psi24,131 kPa241 bar
Flow Range to: 50 gpm180 lpm
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
45/86Hydraulic Filtration 1www.buydonaldson.com
W610Max Flow: 50 gpm (189 lpm)
Differential Indicators: Indicators are designed to actuate at approximately 80% of bypass valve cracking pressure. It is recommendedthat an indicator with a bypass setting of 100 psid is used with a non-bypass housing.
Surge Control: This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surgecontrol delays the indicator response.
Thermal Lockout: The Thermal Lockout prevents premature signaling of a bypass condition created by viscous fluid during cold start-ups.Normal indicator actuation capability is resumed once the operating temperature of the fluid reaches approximately 80F / 27C.
Note: The female plug (connector) is to
be furnished by customer.
W610 Specification Illustrations
Head - Top View
Assembly - Side View
Plastic Electrical Housings
Aluminum Electrical Housings
Note: The female plug (connector) is tobe furnished by customer.
Indicator Switch
Schematic Wiring Diagram
All dimensions are shown in millimeters [inches].
Manifold Mounting
Inlet and Outlet PortO-rings (-120) supplied
69.34
(2.73)
61.20(2.41)
Drain Plug9/16-18UNFSAE 6 Straight Thread
33.27(1.31)
Hex
Bleed Plug7/16-20UNFSAE 4 Straight Thread
P Indicator
13.97(.55)
28.58(1.12)
57.15(2.25)
61.21(2.41)
94.49(3.72) 47.24
(1.86)
7/16 -14UNC-2B Thd2 Plcs X 22.35(.88) Deep
52.32(2.06)
26.16(1.03)
38.10(1.50)
Outlet Port30.23 (1.19) C'Bore Dia
23.37 (.92) Flow Port Dia
7/16-14UNC-2B ThdThru 4 Plcs
77.72 Max(3.06)
Inlet Port
63.50 Min (2.50) Req'd For Element And Bowl Removal
Visual - 38.10 Max (1.50)Electrical - 49.53 Max (1.95
Refer ToModel Code
(Assembly Length)
Inlet Port
30.23 (1.19) C'Bore Dia21.34 (.84) Flow Port Dia
Torque Bowl to20 N.M (15 Lbs-Ft) Max
IN
65.02(2.56)
57.15(2.25)
28.45(1.12)
94.49(3.72)
47.24(1.86)
7/16-14UNC-2BThd Thru 4 Plcs
Outlet Port
88.39(3.48)
Refer to Filter Choices(Assembly Length)
8/13/2019 donaldson visokotlani filteri
46/86172 Hydraulic Filtration www.buydonaldson.com
W610Max Flow: 50 gpm (189 lpm)
High-Performance DT Filter ChoicesW610 Components
Performance Data
Filter Notes All Donaldson DT filters utilize glass fiber media with an epoxy-based resin system for the ultimate in chemical compatibility.
All Donaldson DT filters are potted with epoxy-based adhesives.
Standard collapse DT designs are double wire-backed using epoxy-coated steel mesh for maximum pleat support and dirt capacity.
High collapse designs are double wire-backed using stainless steel mesh.
High collapse designs are also potted into machined aluminum endcaps for greater filter integrity in critical applications.
Vitonseals are standard on all Donaldson DT filters. Vitonis a registered trademarks of E. I. DuPont de Nemours and Company.
W610 4" DT Filter OnlyDT-9800-4, 4"/102mm
W610 4" DT Filter OnlyDT-9801-4, 4"/102mm
W610 8" DT Filter OnlyDT-9801-8, 8"/203mm
W610 Housing Only
Bypass Valve
0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
0
20
40
40 50 60
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
Flow Rate (gpm)
0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
0
20
40
60
80
100
120
140
160
0 40 80 120 160 200
0
5
10
15
20
25
0 10 20 30 40 50 60
PressureD
rop
(kPa)
Flow Rate (lpm)
PressureD
rop
(psid)
Flow Rate (gpm)
5m
8/13/2019 donaldson visokotlani filteri
47/86Hydraulic Filtration 1www.buydonaldson.com
W610Max Flow: 50 gpm (189 lpm)
Housing Ordering Guide
Table 1
Filter Assembly
CODE DESCRIPTION
W610 Assembly
Table 2
Filter Collapse Options
CODE DESCRIPTION 1 150 psid for housing
w/bypass valve
4 3000 psid for housing
without bypass valve
Table 3
Port Size Options
CODE PORT SIZE
A SAE-12 O-ring
B SAE-16 O-ring
F 1" SAE 4-Bolt FlangeCode 61
M 1" SAE 4-Bolt Flange
Code 62
S Manifold Mounting
Table 4
Bypass Setting Options
CODE BYPASS SETTING
1 Non-bypass
4 50 psid
6 90 psid
Table 7
Assembly & Filter Length
CODE (LGTH) FILTER LENGTH
1 (6.75") 4.0"
2 (10.40") 8.0"
W610 1 A 4 J N B 1
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7
Metric Porting Available
Change W610 to G610
Porting code A becomes G3/4"ISO 228 BSPP
Porting code B becomes G1"ISO 228 BSPP
Porting code F becomes 1" SAE 4 boltflange with M10 mounting threads
Porting code M becomes 1" SAE 4 boltflange with M12 mounting threads
Table 5 (Secondary)
Receptacle Options
CODE ELECTRICAL STYLE
B Brad Harrison(5-pin)
H Hirschmann(4-pin)
N None, for visual DPindicator
Table 6Seal Options
CODE MATERIAL
B Buna-N
V Viton
Filter
Assembly
Service
FilterFilters ordered separately. See previous page for filter options.
LEAD TIME NOTE:
This product is configured with the specifications andfeatures of your choice. Please contact your Donaldsonsales representative for lead time details.
Media Ratings
Western Filter elements have been replaced by
Donaldson DT high-performance cartridges.
WESTERN DONALDSONMEDIA CODE DT MEDIA
01
8/13/2019 donaldson visokotlani filteri
48/86174 Hydraulic Filtration www.buydonaldson.com
FPK04 In-Line Cartridge Filters
The FPK04 T-type ported series offers flows up to 100 gpm (379 lpm) with a bypass option and
conforms to the HF3 automotive standard.
Donaldson Synteqmedia is offered in a variety of designs. Upgraded Donaldson high-performance DT
filters are also offered for superior performance. The differential pressure indicator line is designed to work
with the wide assortment of bypass valve options.
Working Pressures to: 4350 psi30,000 kPa300 bar
Rated Static Burst to: 9135 psi63,000 kPa630 bar
Flow Range to: 100 gpm379 lpm
Conforms to HF3 specifications
High collapse filters available for use
with non-bypass applicationsWide range of indicator options
Three housing length options for design flexibility
Buna-Nseals standard, Vitonavailable
Head material: cast ironHousing material: steel
DT Replacement Filter Lengths
4.56" / 116mm 4.59" / 116.7mm 8.19" / 208mm 8.22" / 208.8mm
Beta Rating Performance to
8/13/2019 donaldson visokotlani filteri
49/86Hydraulic Filtration 1www.buydonaldson.com
13.60 [345.5]
9.94 [252.5]
5.59 [142.0]
5.59 [142.0]
5.59 [142.0]
18.37 [466.50]
Head - Top View
Assembly - Side View
FPK04Max Flow: 100 gpm (379 lpm)
FPK04 Specification Illustrations
2.24 [57.0]
3.70 [94.0]
All dimensions are shown in inches [millimeters]. Applications
High Pressure Circuits In-Plant Systems
Meets HF3 Specification Mobile Equipment Servo Valve Circuits
8/13/2019 donaldson visokotlani filteri
50/86176 Hydraulic Filtration www.buydonaldson.com
Port Size Bypass Rating Indicators Part No.
SAE-20 87 psi / 6 bar plugged only P568720
SAE-20 No bypass plugged only P568721
Head Choices
NotesHousings include the head to housing seal.
Housing Choices Indicator ChoicesFilter Length Part (in.) No.
4.6" P568722
8.2" P568723
12.9" P568724
Set Point / Type Part No.39 psi/2.7 bar ele N.O. P165194
39 psi/2.7 bar ele N.C. P167455
FPK04 ComponentsHigh-Performance DT Filter Choices
Filter Notes
All Donaldson DT and DX2 filters utilize glass fibermedia with an epoxy-based resin system for theultimate in chemical compatibility.
All Donaldson DT and DX2 filters are potted with
epoxy-based adhesives. Standard collapse DT designs are double wire-
backed using epoxy-coated steel mesh formaximum pleat support and dirt capacity.
High collapse designs are double wire-backedusing stainless steel mesh.
High collapse designs are also potted intomachined aluminum endcaps for greater filterintegrity in critical applications.
Vitonseals are standard on all Donaldson DTand DX2 filters. Vitonis a registered trademark ofE. I. DuPont de Nemours and Company.
DX2 filters utilize nylon mesh for pleat support.
FPK04Max Flow: 100 gpm (379 lpm)
Media x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
DT Synteq Synthetic
8/13/2019 donaldson visokotlani filteri
51/86Hydraulic Filtration 1www.buydonaldson.com
Filter Element
Housing
Drain Plug
FPK04 Service Parts
FPK04Max Flow: 100 gpm (379 lpm)
Head
Indicator
PlugRemove only wheninstalling indicator
Standard Filter Choices
Media x(c) = 2 x(c) = 1000 Length Donaldson Comments
Type Rating based on ISO 16889 in mm Part No.
Synteq Synthetic
8/13/2019 donaldson visokotlani filteri
52/86178 Hydraulic Filtration www.buydonaldson.com
Performance Data
FPK04Max Flow: 100 gpm (379 lpm)
FPK04 4" Standard Filter Only4.62"/117.3mm
FPK04 Housing Only
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)
Flow Rate (lpm)
0
5
10
15
20
25
0 10 20 30 40 50 600
20
40
60
80
100
120
140
160
0 50 100 150 200
FPK04 8" Standard Filter Only8.20"/208.3mm
Flow Rate (gpm)
Pressure
Drop
(psid)
Pressure
Drop
(kPa)