26
Release Notes EMC Storage Resource Management Suite Release number 3.0 Release Notes P/N 302-000-508 REV 02 January 03, 2014 These release notes contain supplemental information about EMC ® Storage Resource Management Suite release 3.0. Topics include: u Revision history ......................................................................................................... 2 u Product description .................................................................................................... 2 u New features and changes ......................................................................................... 2 u Known problems and limitations ................................................................................ 5 u Installation .............................................................................................................. 20 u Environment and system requirements .................................................................... 20 u Technical notes ........................................................................................................ 20 u Troubleshooting and getting help ............................................................................. 22 u Documentation ........................................................................................................ 22

Docu51321 Storage Resource Management 3.0 Release Notes

Embed Size (px)

DESCRIPTION

Docu51321 Storage Resource Management 3.0 Release Notes

Citation preview

  • Release Notes

    EMC Storage Resource Management SuiteRelease number 3.0

    Release NotesP/N 302-000-508REV 02January 03, 2014

    These release notes contain supplemental information about EMC Storage ResourceManagement Suite release 3.0. Topics include:u Revision history......................................................................................................... 2u Product description....................................................................................................2u New features and changes......................................................................................... 2u Known problems and limitations................................................................................5u Installation.............................................................................................................. 20u Environment and system requirements.................................................................... 20u Technical notes........................................................................................................20u Troubleshooting and getting help.............................................................................22u Documentation........................................................................................................ 22

  • Revision historyThis table records the revisions made to this document.Revision Date Description

    - - -01 December 20, 2013 GA release of the product.02 January 03, 2014 Post-GA update of Known problems and

    limitations on page 5.

    Product descriptionEMC Storage Resource Management Suite provides comprehensive monitoring,reporting, and analysis for heterogeneous block, file, and virtualized storageenvironments. It enables you to visualize applications to storage dependencies, monitoranalyze configurations and capacity growth, as well as optimize your environment toimprove return on investment.Virtualization enables businesses of all sizes to simplify management, control costs andguarantee uptime. However, virtualized environments also add layers of complexity to theIT infrastructure, that reduce visibility and can complicate the management of storageresources. Storage Resource Management Suite addresses these layers-simply-byproviding visibility into the physical and virtual relationships to ensure consistent servicelevels. As you build out your cloud infrastructure, SRM Suite helps you ensure storageservice levels while optimizing IT resources both key attributes of successful clouddeployments.

    New features and changesEMC Storage Resource Management Suite, release 3.0 includes consolidates Watch4netwith storage related SolutionPacks, ProSphere topology and capacity metrics, and thecompliance features of Storage Configuration Advisor into one product with a single userinterface, installation, and discovery process.EMC Storage Resource Management Suite (SRM Suite) provides comprehensivemonitoring, reporting, and analysis for heterogeneous block, file, and virtualized storageenvironments. It enables you to visualize applications to storage dependencies, monitorand analyze configurations and capacity growth, as well as optimize your environment toimprove return on investment.Virtualization enables businesses of all sizes to simplify management, control costs andguarantee uptime. However, virtualized environments also add layers of complexity to theIT infrastructure, that reduce visibility and can complicate the management of storageresources. Storage Resource Management Suite addresses these layers simply byproviding visibility into the physical and virtual relationships to ensure consistent servicelevels. As you build out your cloud infrastructure, SRM Suite helps you ensure storageservice levels while optimizing IT resources - both key attributes of successful clouddeployments.New features in SRM Suite coreThe SRM Suite combines the three separate products from the previous version(ProSphere, SCA, and Watch4net) into a single integrated software stack that delivers allthe capability of the previous version plus more. It provides configuration, capacity, and

    Release Notes

    2 EMC Storage Resource Management Suite 3.0 Release Notes

  • performance reporting, alerting, topology, and storage compliance, in one product with asingle user interface, installation, and discovery process:u Quick installation of the product into Windows, Linux, and VMware environments.u Ability to check for core component and SolutionPack updates, download them, and

    then notify you that they are available for installation.u Windows host agent that collects data without requiring any credentials on the host.u Host capacity utilization reporting that allows the storage admin to see how existing

    capacity is being utilized.u Consolidated capacity reporting across the EMC VMAX and VNX arrays.u Accurate and flexible reporting of capacity allocation to clusters.u Management of SLAs and Chargeback reports in terms of FAST Policy or disk/array

    characteristics.u A new use-case driven user interface.u Performance monitoring and troubleshooting.u Topology maps, end-to-end tabular views of the data.u Consolidated monitoring of health, configuration, compliance breaches, and

    threshold-based alerts.u Tabular summaries of information about zonesets, zones, and zone members.u Global search across all discovered configuration items.u A consolidated Alert console that includes:

    l Alerts for breaches of EMC's eLab Support Matrix and configuration best practicesl EMC PowerPath health metricsl Threshold alerts based on performance datal Health alerts collected from Brocade switches, Cisco switches, VMware, and VNX

    and VMAX arraysNew SolutionPacksSRM Suite includes these new SolutionPacks:SolutionPackName

    Description Available Reports- - -SolutionPack forIBM SVC/V7000

    The IBM System Storage SANVolume Controller (SVC)SolutionPack for IBM SVC/V7000 isa member of the IBM Storwizefamily providing storagevirtualization with a single point ofcontrol for storage resources. Itenables users to generate both real-time and historical reports byaccessing the capacity andperformance details to gain insightinto the management of theirunderlying Storwize storageenvironment.

    SolutionPack forEMC RecoverPoint

    The SolutionPack for EMCRecoverPoint enables users togenerate both real-time and

    l RecoverPoint Summaryl Traffic Metrics

    Release Notes

    New features and changes 3

  • SolutionPackName

    Description Available Reports- - -

    historical performance reports asspecified for the data replicationfrom any of the supported SAN-based arrays to any other SAN-based arrays. The summary reportsfor key components such as EMCRecoverPoint Appliance (RPA),Clusters, Consistency GroupMetrics, and so on, and I/Othroughput analysis for SAN systemtraffic provide a deeperunderstanding of the overallreplication schemes in place andthe policies that govern them.

    SolutionPack forStorageCompliance(EssentialarchitecturalSolutionPack)

    The SolutionPack for StorageCompliance feature analyzes theconfiguration changes in yourdatacenter for policy complianceand detects breaches against thosepolicies.

    l Manage Rules and Policiesl Breach Reportl Match to EMC Support Matrix

    SolutionPack forEMC Host Interface

    The SolutionPack for EMC HostInterface discovers physical servers.A global view of all hosts in a datacenter with a drill down on hosttopology, capacity utilization andperformance measurements onhosts. Reports host capacity bysummarizing storage LUNs mappedon host file systems and provide adetailed report on Storage Capacity.

    Note

    SolutionPack for EMC Host Interfacedoes not support PowerPath in theSRM Suite 3.0 release. PowerPathdata is available through agentlessdata collection only in SolutionPackfor Physical Hosts and SolutionPackfor VMware vCenter.

    l Host Enterprise DashboardHost Information and detailsFile Systems, VolumeManagement summary reportLocal and Remote Disk CapacityReportsService level for LUNs mapped tohost file systemsPerformance metrics for hostdevices namely CPU, Memory,Disks

    SolutionPack forPhysical Hosts

    The SolutionPack for Physical Hostsenables users to monitor andgenerate both real-time andhistorical reports regarding theperformance of physical hosts andto gain better insight intoparameters such as capacity andutilization associated to aninventory of File Systems, VolumeGroups and Disks (both local andremote).

    l Host Enterprise DashboardHost Information and detailsFile Systems, VolumeManagement summary reportLocal and Remote Disk CapacityReportsService level for LUNs mapped tohost file systems

    Release Notes

    4 EMC Storage Resource Management Suite 3.0 Release Notes

  • SolutionPackName

    Description Available Reports- - -

    Performance metrics for hostdevices namely CPU, Memory,Disks

    SolutionPack forEMC DataProtection Advisor

    The SolutionPack for EMC DataProtection Advisor (DPA) helps youperform capacity management andchange management through thesingle pane of the user interface. Italso generates alerts and helps introubleshooting of your replicationand backup environmentdiscovered and monitored throughDPA.

    Replication:l RPO Compliancel Alertsl CapacityData Domainl Configurationl Performancel Replication

    Updated SolutionPacksThe list of updated SolutionPacks is as follows. For details on the updates, see thespecific SolutionPack Readme.u SolutionPack for Brocade FC Switchu SolutionPack for Cisco MDS/Nexusu SolutionPack for EMC VPLEXu SolutionPack for Physical Hostsu SolutionPack for VMware vCenteru SolutionPack for VirtualWisdomu SolutionPack for EMC VMAXu SolutionPack for EMC VNXu SolutionPack for Hitachi Device Manageru SolutionPack for NetApp Filer now includes support for Cluster Mode (C-Mode).SolutionPacks not supportedSRM Suite 3.0 does not support the SolutionPack for ProSphere-SCA.

    Known problems and limitationsThis topic lists the known issues and limitations in each Storage Resource ManagementSuite component first alphabetically by the component name, and then in descendingorder of the issue number.

    CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -651395 Alert Consolidation For Compliance breaches, the All

    Alerts report does not display CreatedAt and Modified At data.

    Use the Operations > Compliance > Breachinstead.

    Release Notes

    Known problems and limitations 5

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -651349 Alert Consolidation If the APG webservice is not reachable,

    File not found Exceptionentry is found in the EPM log.

    Ignore the exception. It is removed on successfulconnection to the APG webservice.

    650764 Alert Consolidation All Alerts report does not show alertsreceived from external sources if thesystem time of the source is ahead(later than) the SRM Suite host.

    Ensure that the system time of alert sources andSRM Suite are in sync at all times in order to viewalerts in the All Alerts report as soon as they areprocessed.The delayed alerts appear in the All Alerts report aswhen the suite host timestamp crosses the systemtimestamp of the alert source.

    650225 Alert Consolidation During SolutionPack for Brocade FCSwitch installation entry of themandatory email address result inemail notifications only for the CreditLoss alerts, and is applicable to emailnotifications for alerts consolidated.

    Disable the corresponding alert definition in theAlerting Frontend.

    650018 Alert Consolidation Alert consolidation continues to workafter uninstallation of the followingSolutionPacks:l Brocade FC Switchl Cisco MDS/Nexusl EMC VMAX

    The "Infrastructure Preparation for Discovery andData Collection" chapter in the EMC StorageResource Management Suite Installation andConfiguration Guide describes the procedure forenabling alert consolidation for each alert source.l For Brocade and Cisco switches, apply the same

    procedure used for enabling alert consolidationto disable SNMP trap forwarding by logging intoeach switch.

    l For VMAX, apply the same procedure used forenabling alert consolidation to disable SNMPtrap forwarding by removing trap recipient IPsfrom the daemon_options file in therespective Solutions Enabler (SE).

    612178 Alert Consolidation User Datagram Protocol (UDP) nature ofSNMP traps for VMAX arrays fromSolutions Enabler, the suite fails toreceive and display some alerts. If atrap is lost in the networkcommunication, Solutions Enabler isnot aware of the loss and cannotresend the lost information.

    There is not workaround available.

    611574 Browser support When using Internet Explorer (IE) 9 theissues are:l In the Login screen, Sign In is

    disabled.l In Centralized Management, the

    main view and the navigationpanel are blank.

    l To enable Sign In in the Login screen, add theSRM Suite URL to the IE Local Intranet zone.

    l To view all Centralized Management features,either disable the IE Pop-up Blocker, or add theSRM Suite URL to the Pop-up Blocker exceptionlist.

    Release Notes

    6 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -602585 Browser support When using Internet Explorer 8 to

    install a SolutionPack, the installermight fail to start.

    Close the current selection and then select theSolutionPack again.For more information, see Primus article emc324861.

    602584 Browser support There are browser refresh issues whenusing IE8.

    There is no workaround available.

    N/A Browser support(SolutionPack forStorageCompliance)

    In IE 8, only Breach Report isaccessible under Operations >Storage Compliance. The other twoadministrative options are accessibleonly in IE versions 9 and 10:l Manage Rules & Policies and all

    associated policy administrationoptions

    l Match to EMC Support Matrixadministration option

    There is no workaround available.

    612531 End-to-End reports Passive hosts are not reported in theconnectivity and path details topologyreports for switches and storagesystems.

    Connectivity and path details for passive hosts arereported in the context of the passive host itself.These reports can be opened in Explore > PassiveHosts, or by searching for the passive host.

    612528 End-to-End reports When VM is deleted in Virtual Centerand recreated on a different ESX server,it might be reported in the topologymaps as related to both the old andnew ESX servers.

    Contact EMC Customer Support for a workaround todisassociate the VM from the old ESX server.

    612514 End-to-End reports Selection of a fabric or VSAN node inthe map does not display any reports.

    You can view reports for the fabric or VSAN byselecting or searching for it in Explore > SANConnectivity > Fabric.

    611981 Web GUI-Frontend Auto-suggest filter does not work inAlerting, Events, Compliance, andOperations > Inventory > StorageInventory > Connected LUNs.

    There is no workaround available.

    650976 Web GUI-Frontend When you export reports in PDF formatfrom Explore > Hosts > , the suite does not includethe topology map.

    There is no workaround available.

    611749 Web GUI-Frontend When a LUN (or any other component)is remove from an array, it takestwenty-four hours to be excluded fromthe global reports.

    There is no workaround available.

    N/A Global CapacityReporting

    Certain cells in the report for Symmetrixor CLARiiON arrays are empty ormissing data for the following reasons:l Discovery of the arrays takes

    longer than 15 minutes.

    This is expected behavior. To enable efficient, error-free discovery, ensure that you:l Restrict only one Symmetrix or CLARiiON array to

    each collector.

    Release Notes

    Known problems and limitations 7

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    l Discovery stopped due to errors. l Check your logs to identify the cause of anyerrors that are preventing successful discovery,and correct them.

    N/A Global CapacityReporting

    Some configuration data for a LUN takeup to three collection cycles to be set.

    There is no workaround available, because this isthe expected behavior for configuration data of aLUN, as in the case of the following:l Flags, such as, Is Used, Is Pool Contributor,

    and Is Pool Consumerl Attributes, such as, Purpose (Primary, Local

    Replica, Remote Replica, System Resource)l Attributes, such as, Service Level, Storage

    Group NameSRM Suite requires two collection cycles to computeenterprise capacity metrics (for example, Used,Free, Primary, Service Level Free) accurately. Inbetween collection cycles, you can expect thecapacity values to fluctuate.

    650102 SolutionPack forBrocade FC Switch

    The report issues are:l The Throughput by Fabrics (/s)

    report:l Should be renamed to

    Throughput by Switch (/s).l Should include the unit of

    throughput as million packetsper second (MPPS).

    l Displays the throughput datafor only one switch and not all.

    l The All, None, and Autooptions cannot be applied.

    l The report description isrepeated twice.

    l The Throughput by Port (/s)report:l Does not include the switches

    for which the port data hasbeen generated.

    l The legend descriptions are notcomplete.

    l The All, None, and Autooptions cannot be applied.

    l The report description isrepeated twice.

    There is no workaround available.

    Release Notes

    8 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -649960 SolutionPack for

    Brocade FC SwitchBrocade Access Gateway does notsupport the capabilities (SNMP MIBs)of normal Brocade FC switches. Hence,the SolutionPack does not collect andreport system performance statisticsand FC port statistics for AccessGateways.

    There is no workaround available.

    612826 SolutionPack forBrocade FC Switch

    Switch discovery fails to terminatewhen the seed file contains invalidvalues.

    Ensure that all the values in the seed file are valid the collector group mentioned should be available,and the SNMP version should be correct (v1, v2c,and v3).

    612720 SolutionPack forBrocade FC Switch

    Host names are not resolved correctlywhen zone names have more than 3underscores, and there are digits justbefore the last underscore.

    There is no workaround available.

    611966 SolutionPack forBrocade FC Switch

    Although the path details showconnectivity, end to end topology mapsare broken due to missing fabrics andswitches.A symptom of this issue is that theSNMP Collector starts timing out insuccessive collection cycles due tonetwork issues or unresponsiveswitches. The Collector logs indicatethis behavior with a WARNINGstatement in the format:WARNING -- [EST]-- PollingUnitTable$PollTableTask::catchIOException(): time out afterretrieson agentHost=,Port=

    1. Increase the timeout of switches using thedevice-discovery web application.

    2. Push the updated configuration to the Collector.

    N/A SolutionPack forBrocade FC Switch

    The Interfaces Utilization has nodata in the Interface Type and Speed(Mbps) columns.

    There is no workaround available.

    649888 SolutionPack forCisco MDS/Nexus

    The report issues are:l In the general VSANs report, the

    Number of FC Ports and StaticPorts Configured have 0 as thevalue. Also, the AverageUtilization (/s) column has novalue.

    l In the Name Server Databasereport for individual switches, theFabric Port column has no values.

    There is no workaround available.

    Release Notes

    Known problems and limitations 9

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    l In the VSANs report for individualVSANs, the Static PortsConfigured table, the FC Idcolumn has no values.

    N/A SolutionPack forEMC Data Domain

    The Overview report has no data inthe Serial Number andUncompressed Stored Datacolumns. In addition, the performancecharts in the drill-down data are empty.

    There is no workaround available.

    651443 SolutionPack forEMC Host Interface

    The default performance polling cyclefor SolutionPack for EMC Host Interfaceis 5 minutes .

    During SolutionPack installation or reconfigurationenable 15-minute (900 seconds) polling interval:1. Select Do you want to configure advanced

    settings.2. Click Install.

    651260,650702

    SolutionPack forEMC Host Interface

    SolutionPack for EMC Host Interfacedoes not support EMC PowerPath andVeritas Volume Manager:l If the SolutionPack for EMC Host

    Interface discovers a host on whichPowerPath is installed, there is nodata in the Physical Hosts > HostInformation > Device >PowerPath Reports for HealthSummary, Bus Metrics and LUNMetrics.

    l If SolutionPack for EMC HostInterface is installed on a host withVeritas Volume Manager, incorrectdata is possible in the ReportLibrary > EMC Host Interfacereports for Configured andUnconfigured Disk Capacity, andreports that contain File Systemand Volume Group information.

    There is no workaround available.

    649996 SolutionPack forEMC Host Interface

    Within 5 to 6 hours, significant memoryleak was observed for SolutionsEnabler.

    During SolutionPack installation or reconfiguration:1. Select Do you want to configure advanced

    settings.2. Set Topology Polling Interval to 21600 (6

    hours).651592 SolutionPack for

    EMC VMAXThe bar chart in the Raw CapacityUsage for individual arrays is absentbecause of incorrect reportconfiguration. The report should have

    1. In the User Interface, click Edit Mode.2. Click on Report Configuration, and make the

    following changes:a. Set Default Duration to last 1 week.

    Release Notes

    10 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    time settings of Last 1 Week:average on 1 hour.

    b. Set Sampling Period to 1 hour.c. Set Sampling Type to average.

    3. Click Save.4. Click Browse Mode and return to the report to

    view the bar chart.651270 SolutionPack for

    EMC VMAXThe SolutionPack reports include allVMAX arrays in the environment,including empty entries for VMAXarrays that are not configured forcollection of topology data.

    There is no workaround available. In the reports,ignore all VMAX arrays that have not been configuredfor topology data collection.

    612796 SolutionPack forEMC VMAX

    Masking View Summary report doesnot display any value for Devicecount.

    There is no workaround available.

    612681 SolutionPack forEMC VMAX

    Incorrect Pool Subscribed capacityvalues reported for VMAX arrays. Theaffected report is Explore > Storage >Storage / Storage Systems - Block.

    Note

    Reconfiguration of the SolutionPack overwrites thevhf-vmax3.xml change described here. Therefore,you must repeat this procedure every time theSolutionPack for EMC VMAX is reconfigured.On each VMAX Collector instance in yourenvironment, perform this procedure:1. Click Administration > Centralized

    Management > Logical Overview >Collecting .

    2. Click Variable-Handling-Filter::.Where, is the name of theSolutionPack for EMC VMAX instance.

    3. Under Properties, expand Configuration files.4. Type vhf-vmax3.xml in the Search filter.5. When conf/vhf-vmax3.xml, appears in the

    search result, click next to the file.6. In line 19 of vhf-vmax3.xml, delete the XML:

    (name=='SubscribedCapacity' |name=='OversubscribedCapacity' |name=='RemoveMeZero') &pooltype=='Thin Pool'

    7. In the same location, insert the XML:(name=='SubscribedCa

    Release Notes

    Known problems and limitations 11

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    pacity' |name=='OversubscribedCapacity' |name=='RemoveMeZero') &parttype=='Storage Pool' &pooltype=='Thin Pool'

    8. Under Service Status, click Stop, and thenStart.

    612679 SolutionPack forEMC VMAX

    The suite reports incorrect ConfiguredUsable Including RAID, RAIDOverhead, and Unusable Capacityvalues for VMAX arrays.The affected reports are:l Explore > Storage > Storage /

    Storage Systems - Blockl EMC VMAX > Array Summary >

    > Raw Capacity Usage

    Note

    Reconfiguration of the SolutionPack overwrites thexmlcollector-vmax-topo.xml changedescribed here. Therefore, you must repeat thisprocedure every time the SolutionPack for EMCVMAX is reconfigured.On each VMAX Collector instance in yourenvironment, perform this procedure:1. Click Administration > Centralized

    Management > Logical Overview >Collecting .

    2. Click XML-Collector::.Where, is the name of theSolutionPack for EMC VMAX instance.

    3. Under Properties, expand Configuration files.4. Type vmax-topo in the Search filter.5. When conf/xmlcollector-vmax-

    topo.xml, appears in the search result, click next to the file.

    6. Under the rawcap property, delete XMLmentioned in CQ612679: xmlcollector-vmax-topo.xml file changes on page 20.

    7. In the same location, insert the XML provided in CQ612679: xmlcollector-vmax-topo.xml filechanges on page 20.

    8. Under Service Status, click Stop, and thenStart.

    612590 SolutionPack forEMC VMAX

    The following issues are observed inChargeback reports:Total Presented and Total UsedChargeback capacities for a Host/HyperVisor do not include anySnapshot capacities(VDEVs) of theprimary LUNS. The affected reports are:

    There is no workaround available.

    Release Notes

    12 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    l Explore > Storage > Chargebackby Host/HyperVisor > TotalUsed and Total Presented

    l Explore > Storage > Chargebackby HyperVisor Cluster > TotalUsed and Total Presented

    l Dashboard > Storage >Chargeback by Group > TotalUsed and Total Presented

    Local Replica Used capacity does notinclude any Snapshotcapacities(VDEVs) of the primary LUNS.The affected reports are:l Dashboard > Storage > Used

    Capacity by Purpose > LocalReplica Used Capacity

    l Explore > Storage System Block> Local Replica Used Capacity

    610764 SolutionPack forEMC VMAX

    Capacity numbers may fluctuate for alimited period during active datacollection.

    There is no workaround available.

    N/A SolutionPack forEMC VMAX

    Connectivity report for NPIV GatewaySwitch incorrectly includes virtualconnectivity along with physicalconnectivity. Only physical connectivityshould be used in this report.

    There is no workaround available.

    649279 SolutionPack forEMC VNX

    Report Library > EMC VNX > TreeQuota reports are missing from VNXFile.

    There is no workaround available.

    612779 SolutionPack forEMC VNX

    The Usable Capacity by Pool > BlockPools report (VNX) does not containdata in LUN Contributors,Consumers , and Disk Contributorstables.

    Use the Explore > Storage > Block Pools tablesinstead.

    612651 SolutionPack forEMC VNX

    When upgrading from EMC Watch4net6.2.4 to 6.3 in a distributedenvironment, SEVERE errors appear forthe following files in the SolutionPack:l pre-replica-chain.csvl usedby.csvl poolraidluns.csv

    There is no workaround available.

    Release Notes

    Known problems and limitations 13

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -612413 SolutionPack for

    EMC VNXIn Explore > Block Pools Global ,Snap Pools have no pool consumers inthe Consumers column.

    There is no workaround available.

    612345 SolutionPack forEMC VNX

    In the Storage Capacity Presentedto NAS Report report for individualVNX arrays, the Free Capacity onUsed Disks(GB) column may displaynegative values.

    There is no workaround available.

    612300 SolutionPack forEMC VNX

    In the Usable Capacity by ServiceLevel report, the columns remainempty when they should display thevalue 0.

    There is no workaround available.

    612219 SolutionPack forEMC VNX

    Meta LUN performance charts do notcontain any data.

    There is no workaround available.

    612151 SolutionPack forEMC VNX

    The tooltips in the Usable Capacityand Used by Purpose reports (VNXand Enterprise) do not match the reportdata.

    Ignore the tooltips. The report data is correct.

    611697 SolutionPack forEMC VNX

    The SolutionPack does not support ESXNFS datastores.

    There is no workaround available.

    610219 SolutionPack forEMC VNX

    When a pool contains a list of LUN IDsthat collectively exceed 4096characters, the Pool Name does notappear in the Pool Summary report.

    1. Navigate to the #/opt/APG/bin/apg.properties.

    2. Under the system property, addrestricted.reader.line.size=32768.

    3. Wait for 1 hour and then recheck the PoolSummary report for the appearance of PoolName.

    609662 SolutionPack forEMC VNX

    The SolutionPack does not tag commonLUNs with all the storage groups towhich the common LUNs are members.

    There is no workaround available.

    644238 SolutionPack for HP3PAR StoreServ

    The capacity units for total, free,allocated and failed capacity in HP3PAR StoreServ Solution pack do notmatch with those shown in 3PAR CLI.The Usable Capacity Report will showcapacity units in GB instead of TB unit.

    1. In the User Interface, click Edit Mode.2. Click Report Details: Graph, and make the

    following changes:3. Change the By Unit value from MB to GB.4. Change To Unit to Auto.5. Click Save.6. Click on Browse Mode and check the report.7. Repeat the steps 1 through 4 for Free Capacity,

    Allocated Capacity and Failed Capacity.N/A SolutionPack for

    Microsoft Hyper-VOne volume report underAll Volumes >Volume List displays the following

    There is no workaround available.

    Release Notes

    14 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    text for the By File Type graph: Thisgraph doesn't supportnegative values...

    651414 SolutionPack forNetApp Filer

    Report Library > NetApp Filer >Storage Systems Summary > 7-Mode > FilerName > Details >Snapshots report does not displayvolume details. Aggregate details mightincorrectly include volume data.

    There is no workaround available.

    651331 SolutionPack forNetApp Filer

    If a disk name is the same in multiplenodes of a cluster, the Total Diskscolumn displays incorrect data in theReport Library > NetApp Filer >Storage Systems Summary > C-Mode report.

    1. Click Report Library > NetApp Filer > StorageSystems Summary > C-Mode, and then clickEDIT MODE.

    2. Expand the C-Mode report.3. Click the child Node C-Mode Filer, and then

    the arrow next to C-Mode Filer.4. In the NetApp Filer > > C-Mode

    Filer that opens, click Formula.5. Click util.DistinctValueCountFormula , and

    then Settings.6. In Expand on field for Value, type

    device,part .7. Click Save and wait until the Save

    Successful message appears.8. Click BROWSE MODE to return to the normal

    report view.651358 SolutionPack for

    NetApp FilerThe Report Library > NetApp Filer >CPU Utilization report shows the totalCPU busy time instead of the averageCPU busy time.

    1. Click Report Library > NetApp Filer > CPUUtilization , and then click EDIT MODE.

    2. Click Filtering & Expansion .3. Click the filter CpuBusyTotal.4. Click Edit, and type CpuBusyAvg.5. Click Save and wait until the Save

    Successful message appears.6. Click BROWSE MODE to return to the normal

    report view.651359 SolutionPack for

    NetApp FilerIncorrect unit conversion results ininaccurate values in the Saved Spacecolumn of the Report Library >NetApp Filer > Capacity >Deduplication report.

    1. Click Report Library > NetApp Filer > Capacity> Deduplication.

    2. Click Report Details: Table .3. Expand Value:Saved Space , and then expand

    Value Settings.

    Release Notes

    Known problems and limitations 15

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    4. In Scaling Mode > Unit, type TB.5. Click Save and wait until the Save

    Successful message appears.6. Click BROWSE MODE to return to the normal

    report view.651204 SolutionPack for

    Physical HostsSolutionPack forEMC Host Interface

    The suite reports inaccurate data for ahost configured for discovery in bothSolutionPack for Physical Hosts andSolutionPack for EMC Host Interface.

    Configure the host for discovery only on oneSolutionPack, and not both.

    N/A SolutionPack forPhysical HostsSolutionPack forVMware vCenter

    The Inventory > List all servers > chart for CPU Usage (%) hasno data.

    There is no workaround available.

    651142 SolutionPack forPhysical Hosts

    In LUN Path Health and LUN Metricsreports for Windows hosts, a fewdevices and LUNs might be duplicated.These reports might contain containingpartial or empty data in a few columns.

    There is no workaround available.

    650667 SolutionPack forPhysical Hosts

    The suite does not support PowerPathreports for HP-UX-11.23 due tooperating system limitations.PowerPath reports and alerts aresupported only for HP-UX 11.31.

    There is no workaround available. The suite supportsPowerPath reports in HP-UX 11.31 and later.

    649903 SolutionPack forPhysical Hosts

    Host data collection fetches partial CPUname on select Sun Solaris hosts.

    There is no workaround available.

    649651 SolutionPack forPhysical Hosts

    The WS-MAN (Web ServicesManagement) APIgetFCPTargetMapping function returnsincorrect number of LUNs on Windows2003 and 2008.The problem is seen on problem isseen on old HBA models QlogicQLA2340 and QLA2342. These arelegacy HBA IO cards that are supportedonly on older servers running Windows2003 and Windows 2008.

    Contact your EMC Customer Service Engineer toobtain the INQ binary executable to fix this issue.

    612657 SolutionPack forPhysical Hosts

    Initial selection of the StorageConnectivity report for physical hostsdoes not show any connections.

    Click a different device in the map (for example, aswitch or array), and then click the original hostagain.

    611214 SolutionPack forPhysical Hosts

    In LUN Path Health and LUN MetricReports for some hosts, a few devicesor LUNs might be duplicated containingpartial or empty data in a few columns.

    Ignore the empty or partial data rows for duplicateddevices.

    Release Notes

    16 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -N/A SolutionPack for

    Physical HostsThe Uptime column in the HostInformation report has no data.

    There is no workaround available.

    651345,611302

    SolutionPack forStorageCompliance

    Solutions Enabler, HBA firmware andvendor details for ESX servers are notavailable for compliance rules thatinvolve checks related to multi-pathingsoftware. This information is currentlynot part of the VMware discovery datacollection.

    There is no workaround available.

    651255 SolutionPack forStorageCompliance

    Rules are not populated in the CreatePolicy > Rules when the defaultpolicies are selected in the followingscenario:1. You select a policy template when

    creating a policy.2. Create a scope for the policy.3. Change the policy template to

    some other entry.The rules corresponding to thisnew selection are not displayed.

    1. Cancel the policy creation.2. Create a new policy.

    650644 SolutionPack forStorageCompliance

    Bulk matched items show up in thesame report view irrespective of thepage number set.

    Refresh the report view.

    651266 SolutionPack forVMware vCenter

    After discovering LUN and path relateddata (present in the database and userinterface), if a LUN is removed fromhost, the LUN and path data persist inthe database and user interface.

    There is no workaround available.

    650617 SolutionPack forVMware vCenter

    In Report Library > VMware vCenter >Situations to Watch > DiskBottleneck Analysis report, there isno data in the following columns:l IOPSl Throughput/sl Queue Latencyl Total Latency

    There is no workaround available.

    644756 SolutionPack forVMware vCenter

    The query AvailablePerfMetricsdisplays no data for the discoveredvCenter.

    There is no workaround available.

    644003 SolutionPack forVMware vCenter

    Missing or stale data are displayed forVMware reports when vCentercredentials expire.

    The credentials used to discover a vCenter in vCentersolution pack should be kept updated and current. Itis advisable to use passwords which do not expire.

    Release Notes

    Known problems and limitations 17

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -612776 SolutionPack for

    VMware vCenterVirtual Applications report for VMs ismissing the following metrics:l VCPUsl Memory sizel CPU Usagel %CPU

    There is no workaround.

    612419 SolutionPack forVMware vCenter

    IP Network details are not available forHypervisor (ESX).

    There is no workaround available.

    612386 SolutionPack forVMware vCenter

    On Windows Collectors, performancecollection does not occur despiteselection of Collect PerformanceMetrics for PowerPath LUNs duringSolutionPack.

    Manually edit the value of thepowerPathPerformanceCollection flag inthese files:l For Windows hosts

    LunMappingDetection.ps1l For ESX-Windows hosts

    ESXPowerPathPerformance.ps1

    612332 SolutionPack forVMware vCenter

    If ESX servers have vMotion that is notactivated, the IP address is notavailable in Explore > Hosts >Hypervisor report. This is because,typically, there are several IPs assignedto an ESX server. Of these IPs, the suiteonly collects the property ip from the IPthat is unique to vMotion.

    There is no workaround available.

    612328 SolutionPack forVMware vCenter

    At times, Storage Connectivity >Connectivity reports for VMs and ESXservers do not display any data forswitch port WWN data.

    There is no workaround available.

    611790 SolutionPack forVMware vCenter

    The Path Details report for ESX serversand VMs do not contain paths for NFSDatastores.

    There is no workaround available.

    610125 SolutionPack forVMware vCenter

    Some capacity and configurationreports might report incorrect datawhen different virtual machines areconfigured in VMware vCenter with thesame display name.

    There is no workaround available.

    N/A SolutionPack forVMware vCenter

    The Situations to Watch > VirtualMachines CPU Bottleneck report hasno metric and CPU Ready By O.S (%)data.

    There is no workaround available.

    N/A SolutionPack forVMware vCenter

    The Datacenters Summary > host >Hosts > > Virtual Machines >Virtual Machines report has no data

    There is no workaround available.

    Release Notes

    18 EMC Storage Resource Management Suite 3.0 Release Notes

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    in a few columns, including StoragePath.

    602586 SolutionPack forEMC Watch4netHealth

    Installing theSolutionPack for EMCWatch4net Health using IE8 might fail ifit is the first SolutionPack to beinstalled.

    Install a different SolutionPack first, then install theSolutionPack for EMC Watch4net Health. For moreinformation, see Primus article emc324861.

    612841 Topology NAS Gateway topology maps do notshow complete end-to-end path whengateway is not connected through anAG/NPV switch.

    Use the Path Details report to identify the backendarray. However, there is no workaround available forthe absence of switch data in the StorageConnectivity report.

    612587 Topology Hosts can be seen under PassivelyDiscovered Hosts. However, whenthese hosts are selected, the maps areempty.

    1. Navigate to Administration > CentralizedManagement > Physical Overview > .

    2. In the Services list, click Topology-Mapping-Service - Default.

    3. Click Restart.612584 Topology End-to-end topology maps continue to

    display paths that should not exist,such as when the associated maskingrecord has been deleted.This issue occurs because the deletionof masking is not propagated to thetopology service. Should a physicalpath exist, the suite incorrectlydisplays the path as connected.

    There is no workaround available.

    611966 Topology The Topology Map does not showcomplete end-to-end path for hostsconnected to Symmetrix arrays throughBrocade switches.

    From the device discovery application, check if theswitch discovery has failed due to SNMP timeout. Ifso, increase the timeout and rediscover the switch.

    611704 Topology Data collected from Collectors are notavailable in topology maps. This issueoccurs because the Topology MappingService fails to send data to theBackend after Generic-RSC andGeneric-SNMP are configured on ascaled-out Collector before deployingthe SolutionPack for Brocade FCSwitch, SolutionPack for Cisco MDS/Nexus, and SolutionPack for EMC HostInterface.

    Restart the Topology Mapping Service afterreconfiguring Generic-RSC and Generic-SNMP:1. Navigate to Administration > Centralized

    Management > Physical Overview > .

    2. In the Services list, click Topology-Mapping-Service - Default.

    3. Click Restart.

    611071 Topology The end-to-end topology maps forCisco switches are broken.

    Use the maps for other connected devices, like hostsand arrays, to view fabric and switch topology.

    612754 vApp The single VM vApp is used for both All-In-One vApp installations, as well aspre-configured SRM Suite 3.0 VMssuitable for scaling out an existing SRM

    After deployment of the single VM vApp (with anyrole other than All-In-One vApp), but before startup:1. Log into VMware vCenter.

    Release Notes

    Known problems and limitations 19

  • CQ/Issuenumber

    Component Problem description Workaround /Resolution- - - -

    Suite installation. When used as an All-In-One vApp, the VM is configured withthe right parameters. However, whenused as any other type of VM, the CPUcount is set to 2, which is too low forthe load placed that will be placed onit.

    2. If the vApp is already up, power off the vApp(after making sure the first boot is complete).

    3. Increase the CPU count for the VM from 2 to 4.4. Power on the vApp.

    InstallationThe Storage Resource Management Suite Installation and Configuration Guide, availableon EMC Online Support at https://support.emc.com, provides instructions forinstallation, post-install configuration and supported upgrade paths.

    Environment and system requirementsThe EMC Storage Resource Management Suite Support Matrix, available on EMC OnlineSupport at https://support.emc.com, provides details on system requirements, a list ofsupported operating systems and compatible third-party software.

    Technical notesThis information is intended to supplement any installation procedures or defectworkarounds.CQ612679: xmlcollector-vmax-topo.xml file changesXML to delete:

  • not(contains(configuration,'3-Way')) and not(contains(configuration,'4-Way'))]) then (. * 2) else ( if (../../Dev_Info[contains(configuration,'3-Way')]) then (. * 3) else ( if (../../Dev_Info[contains(configuration,'4-Way')]) then (. * 4) else (.) ) ) ) )" />

    In place of the deleted XML, insert this one:

    Release Notes

    Technical notes 21

  • Troubleshooting and getting helpFor product information and assistance, you can contact EMC Technical Support.Procedureu For documentation, videos, release notes, software updates, or information about

    EMC products, go to EMC Online Support at https://support.emc.com.u For technical support, go to EMC Online Support and click Service Center.

    You must have a valid support agreement to open a service request.u Contact your EMC sales representative for details about obtaining a valid support

    agreement or with questions about your account.

    DocumentationAdditional documentation is available and updated periodically.Table 1 Related documentation

    Document Revision Part number- - -EMC Storage Resource Management 3.0 User and AdministrationGuide

    01 302-000-514

    EMC Storage Resource Management 3.0 Installation andConfiguration Guide

    01 302-000-506

    EMC Storage Resource Management 3.0 Open Source License andCopyright Information

    01 302-000-515

    EMC Storage Resource Management 3.0 Open Source License andCopyright Information for GPLv3 as Included with a Distribution ofSLES 11

    01 302-000-516

    EMC Storage Resource Management 3.0 Ports Usage and Worksheet 01 302-000-507EMC Storage Resource Management 3.0 Documentation Portfolio 01 302-000-517EMC Storage Resource Management 3.0 Security ConfigurationGuide

    01 302-000-513

    EMC Storage Resource Management 3.0 Support Matrix 01 302-000-510

    Electronic versions of the updated manuals are available on EMC Online Support at https://support.emc.com.

    Documentation errataThis section lists corrections required in the documentation.

    EMC Storage Resource Management Suite Installation and Configuration GuideCorrection to "Enabling passive host discovery through Generic-SNMP" procedureReplace the current procedure with the following:1. Click Administration > Centralized Management.

    Release Notes

    22 EMC Storage Resource Management Suite 3.0 Release Notes

  • 2. Click SolutionPacks.3. Under Independent SolutionPack Blocks, click to reconfigure the Generic-SNMP

    SolutionPackBlock instance.4. Select the Enable Passive Host Discovery checkbox.5. Click Reconfigure.6. In Device Discovery > Dashboard > Device Distribution.7. Click Distribute all approved devices with capabilities on all

    enabled collectors.8. Click Send the generated configurations on all available

    collectorsSNMP configurations missing for Brocade switchesIn chapter 5, "Infrastructure Preparation for Discovery and Data Collection," sub-section"Brocade switch configuration," procedures identical to the following Cisco switchconfiguration are required.Configure switches for SNMPv1You have to configure Brocade switches for SNMPv1 to enable discovery, data collection,and alert consolidation for the switches. The SNMPv1 information you provide whenperforming discovery is necessary for SRM Suite to contact the switch to obtaininformation.1. Log into the Brocade FC switch as the administrator.2. Type snmpConfig --set snmpv1 , and press Enter.3. When prompted, type the Community string to be configured on the switch.

    Ignore the other fields that you are prompted to type.Configure switches for SNMPv3You have to configure Brocade switches for SNMPv3 to enable discovery, data collection,and alert consolidation for the switches. The SNMPv1 information you provide whenperforming discovery is necessary for SRM Suite to contact the switch to obtaininformation.1. Log into the Brocade FC switch as the administrator.2. Type snmpConfig --set snmpv3 , and press Enter.3. Type the following details, when prompted:

    Option Description- -User (rw) The SNMP v3 user to be configured on the switch.Auth Protocol [MD5(1)/SHA(2)/noAuth(3)] The authentication protocol required.New Auth Passwd: Authentication password.Verify Auth Passwd: Retype the authentication password.Priv Protocol [DES(1)/noPriv[2]): The Privacy protocol required.New Priv Passwd: The privacy password.Verify Priv Passwd: Retype the privacy password.

    Release Notes

    Documentation errata 23

  • EMC Storage Resource Management Suite Support MatrixCorrection to supported CMCNE/BNA versions in Table 5 Supported models for BrocadeFabric supportIn the topic "SolutionPack for Brocade FC Switch", "Table 5 Supported models forBrocade Fabric", the CMCNE/BNA support should also include CMCNE/BNA 12.x:

    Supported model Collector Prerequisites Port- - - -l Brocade 300, 4100, 4900, 5000, 510, 5300, 5410, 5424, 5450,

    5460, 5470, 5480, 7500, 7500E, 7600l Brocade 7800 Extension Switchl Brocade 8000 FCoE Switchl Brocade Encryption SwitchBrocade DCX

    Backbone and Brocade DCX-4S Backbone: FA4-18 Fibre Channelapplication blade,FCOE10-24 DCX Blade, FS8-18 Encryption Blade, FC8-16 port blade,FC8-32 port blade,FC8-48 port blade, FC8-64 port blade

    l Fabric OS MIB Reference: 53-1001768-01, FC10-6 port blade,FR4-18i router blade, FX8-24 DCX Extension Blade

    l Brocade 48000 director: FA4-18 Fibre Channel application blade,FC4-16 port blade, FC4-16IP, FC4-32 port blade, FC4-48 port blade,FC10-6 port blade, FR4-18i outer blade

    l Brocade VA-40FC

    Generic-SNMPXMLCollector

    All Brocade switches thatare running FOSv4.x orhigher. SNMP compliantwith FC-MGMTMIB.Providers:l CMCNE/BNA 11.1.x,

    11.2.1, 12.xl CMDCE/DCFM 10.4.x

    SNMP(defaultport is161)

    Corrections to footnotes in Table 5 Supported models for Brocade Fabric supportFootnotes b,f, and h for Table 5 are not accurate. They should read as follows:u Footnote b: "SRM Suite requires the integrated SMI Agent (CMCNE/BNA,CMDCE/

    DCFM) to discover NPIV enabled Switch Ports and Access Gateway capabilities."u Footnote f: "Discovery is limited to FC blades. Discovery supports only the E, F, and G

    ports on the blades. SRM Suite does not support Administrative Domains features."u Footnote h is incorrectly applied to only CMCNE/BNA 11.1.x. This note is a generic

    note for all CMCNE/BNA versions, and not specific to CMCNE/BNA 11.1.x.Corrections to Table 6 Supported models for Cisco fabricIn the topic, "SolutionPack for Cisco MDS/Nexus", "Table 6 Supported models for Ciscofabric", the Collector column should only include Generic-SNMP. Remove Text-Collector.Port incorrect in SolutionPack for EMC Host Interface table 12In the topic, "SolutionPack for EMC Host Interface", "Table 12 Supported hosts in SRMSuite", contains a typo. The Port column should have the following content:"Default ports are 5988 and 5989 (secure)"

    EMC Storage Resource Management Suite Security Configuration GuideSolutionPack for EMC VNX: Navisphere SSL certificate settingAdd this new topic to the "Communication security settings" sub-section of the "Securityconfiguration settings" chapter in the EMC Storage Resource Management Suite SecurityConfiguration Guide.

    Release Notes

    24 EMC Storage Resource Management Suite 3.0 Release Notes

  • " Navisphere is installed with a default security level of low. If you need to increase thesecurity level to medium, this can be done using /opt/Navisphere/bin/setlevel_cli.sh.1. At the command prompt, type /opt/Navisphere/bin/setlevel_cli.sh and press

    Enter.2. Type m when prompted:

    Please enter the verifying level(low|medium|l|m) to set?mSetting medium verifying level..... Verification level medium has been set SUCCESSFULLY!!!

    3. Confirm if a Naviseccli command runs without a prompt.

    Release Notes

    Documentation errata 25

  • Copyright 2013-2014 EMC Corporation. All rights reserved. Published in USA.Published January 03, 2014EMC believes the information in this publication is accurate as of its publication date. The information is subject to change withoutnotice.The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind withrespect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for aparticular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable softwarelicense.EMC, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.All other trademarks used herein are the property of their respective owners.For the most up-to-date regulatory document for your product line, go to EMC Online Support (https://support.emc.com). Fordocumentation on EMC Data Domain products, go to the EMC Data Domain Support Portal (https://my.datadomain.com).

    Release Notes

    26 EMC Storage Resource Management Suite 3.0 Release Notes

    Revision historyProduct descriptionNew features and changesKnown problems and limitationsInstallationEnvironment and system requirementsTechnical notesTroubleshooting and getting helpDocumentationDocumentation errata