Generated by Jive on 2015-08-27+02:001
Calibration Business Process
Calibration Process:
I had observed many queries related to calibration process steps,so please refer below which will support you.
Thanks in Advance.
Master Data:
1.Create Equipment master-IE01
2.Create Task list -IA05
3.Create Maintenance plan-IP41
4.Schedule maintenance plan-IP10
Business Process :
Step-1 Deadline monitoring for maintenance plan (Transaction IP30)
Calibration Business Process
Generated by Jive on 2015-08-27+02:002
Enter the Maintenance plan and click
continue
Calibration Business Process
Generated by Jive on 2015-08-27+02:003
Then the plan schedule and automatically tiger the calibration Order Scheduling status was show in Message
text. Then go back
Step-2 To view Maintenance order (Transaction IW39)
Calibration Business Process
Generated by Jive on 2015-08-27+02:004
List of calibration order are Display, Note the Order Number from the List which where you required
Step-3 Check & Release Maintenance order (Transaction IW32)
Calibration Business Process
Generated by Jive on 2015-08-27+02:005
Step-4 Clear the Inspection lot (perform result recording & Usage decision) Transaction -QA32
Calibration Business Process
Generated by Jive on 2015-08-27+02:006
Enter plant & Inspection lot origin-14 click F8 or execute
Step-5 Perform Result recording
Calibration Business Process
Generated by Jive on 2015-08-27+02:007
Select Inspection lot line & click Results (pencil icon)
Calibration Business Process
Generated by Jive on 2015-08-27+02:008
Enter & maintain the result
Calibration Business Process
Generated by Jive on 2015-08-27+02:009
After entering result then valuate the same
Calibration Business Process
Generated by Jive on 2015-08-27+02:0010
Calibration Business Process
Generated by Jive on 2015-08-27+02:0011
Save the results.
Step-6 Perform the Usage decision for Inspection lot
Select the Inspection Lot click Usage decision (pencil icon)
Calibration Business Process
Generated by Jive on 2015-08-27+02:0012
Enter the UD code & Save
Calibration Business Process
Generated by Jive on 2015-08-27+02:0013
UD done
Calibration Business Process
Generated by Jive on 2015-08-27+02:0014
Step-7 Order confirmation (Transaction IW41)
Calibration Business Process
Generated by Jive on 2015-08-27+02:0015
Enter Order Number click Continue
Calibration Business Process
Generated by Jive on 2015-08-27+02:0016
Maintain the required Confirmation data.
Step-8 Technical Completion TECO order (Transaction IW32)
Enter Order Number
Calibration Business Process
Generated by Jive on 2015-08-27+02:0017
Continue
TECO & Save the order.
Note : while creating task list enter PM01 control key for Internal calibartion & PM02 or PM03 for external
calibartion.
Calibration Business Process
Generated by Jive on 2015-08-27+02:0018
Thanks & Regards,
M.Arunkumar