18
Generated by Jive on 2015-08-27+02:00 1 Calibration Business Process Calibration Process: I had observed many queries related to calibration process steps,so please refer below which will support you. Thanks in Advance. Master Data: 1.Create Equipment master-IE01 2.Create Task list -IA05 3.Create Maintenance plan-IP41 4.Schedule maintenance plan-IP10 Business Process : Step-1 Deadline monitoring for maintenance plan (Transaction IP30)

DOC-64772

Embed Size (px)

DESCRIPTION

fdfdsfdfdff

Citation preview

Page 1: DOC-64772

Generated by Jive on 2015-08-27+02:001

Calibration Business Process

Calibration Process:

I had observed many queries related to calibration process steps,so please refer below which will support you.

Thanks in Advance.

Master Data:

1.Create Equipment master-IE01

2.Create Task list -IA05

3.Create Maintenance plan-IP41

4.Schedule maintenance plan-IP10

Business Process :

Step-1 Deadline monitoring for maintenance plan (Transaction IP30)

Page 2: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:002

Enter the Maintenance plan and click

continue

Page 3: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:003

Then the plan schedule and automatically tiger the calibration Order Scheduling status was show in Message

text. Then go back

Step-2 To view Maintenance order (Transaction IW39)

Page 4: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:004

List of calibration order are Display, Note the Order Number from the List which where you required

Step-3 Check & Release Maintenance order (Transaction IW32)

Page 5: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:005

Step-4 Clear the Inspection lot (perform result recording & Usage decision) Transaction -QA32

Page 6: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:006

Enter plant & Inspection lot origin-14 click F8 or execute

Step-5 Perform Result recording

Page 7: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:007

Select Inspection lot line & click Results (pencil icon)

Page 8: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:008

Enter & maintain the result

Page 9: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:009

After entering result then valuate the same

Page 10: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0010

Page 11: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0011

Save the results.

Step-6 Perform the Usage decision for Inspection lot

Select the Inspection Lot click Usage decision (pencil icon)

Page 12: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0012

Enter the UD code & Save

Page 13: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0013

UD done

Page 14: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0014

Step-7 Order confirmation (Transaction IW41)

Page 15: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0015

Enter Order Number click Continue

Page 16: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0016

Maintain the required Confirmation data.

Step-8 Technical Completion TECO order (Transaction IW32)

Enter Order Number

Page 17: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0017

Continue

TECO & Save the order.

Note : while creating task list enter PM01 control key for Internal calibartion & PM02 or PM03 for external

calibartion.

Page 18: DOC-64772

Calibration Business Process

Generated by Jive on 2015-08-27+02:0018

Thanks & Regards,

M.Arunkumar

SAP PLM Functional Consultant