Engineering .Production .Installation .Commissioning
www.dma-marine.com
DMA HVAC&R PRODUCT MANUAL
Turnkey Specialist in Marine and Offshore HVAC&R Systems
丹华奥斯科空调冷藏通风产品手册
Notice
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
DM Alscott Turnkey Specialist in Marine and Offshore HVAC&R Systems
Notice Owing to continued product development, DMA reserves the right to introduce alterations without prior notice. Copyright (c) 2008 – 2009, DMA. All rights reserved. Revision: DM090301 All products listed in the manual are just partial products of DMA, and please contact DMA for more products and further information.
DM Alscott Marine Offshore HVAC Ltd.丹华奥斯科船舶设备(上海)有限公司
www.dma-marine.com
DMA HVAC&R PRODUCT MANUAL
丹华奥斯科空调冷藏通风产品手册
Table Of Contents
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Table Of Contents 1. DMA and HVAC&R 2. DMA Turnkey Case for HVAC&R Systems 3. Marine Air-condition Refrigeration Products 3.1. Marine Air Handling Unit 3.2. Marine Water-cooled Condensing Unit 3.3. Marine Water-cooled Deck Unit 3.4. Marine Water-cooled Packaged Air Conditioner 3.5. Marine Air-cooled Packaged Air Conditioner 3.6. Marine Air-cooled Condensing Unit 3.7. Marine Water-cooled Chiller 3.8. PLC for Marine HVAC system 4. Marine Provision Refrigeration Products 4.1. Marine water-cooled Provision Refrigeration Plant 4.2. Marine Air-cooled Provision Refrigeration Plant 4.3. Marine Air cooler for cold store 4.4. Marine prefabricated Cold Store 5. Marine Ventilation Products 5.1. Marine Axial Flow Fan 5.2. Marine Centrifugal Fan 5.3. Duct Fan 5.4. Cabin Unit 5.5. Galley Canopy 5.6. Air Washer 6. Contact Global DMA
DMA and HVAC&R
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
DM Alscott DM Alscott was formed in 2008 to bring together the combined experience and expertise of Dan Marine Group and
Alscott. This dynamic partnership will provide turnkey HVAC capabilities to the expanding of offshore and marine
industry in China, Far East and Globally.
Alscott Alscott's history dates back to 1956 and have completed the HVAC installations on almost all Canadian built ships
since that time. Alscott specialize in the design, supply, installation and commissioning of Heating, Ventilation and Air Conditioning
(HVAC) for ships, offshore and onshore oil and gas facilities and generally operates as an HVAC sub-contractor to
prime contractors such as shipyards, ship owners, oil companies and project managers. With their head office in Ottawa Ontario and factory facility in Dartmouth, Nova Scotia, Alscott also has
representation and strong business activity in Houston Texas. Alscott International Ltd is strategically located in Freeport Grand Bahama, less than 50 miles from the Florida
coast line and supports ship repair and overhaul from this location. Alscott Middle East Limited is located in Suhar, Oman and supports Alscott’s marine and offshore business in the
Middle East region particularly Dubai and Abu Dhabi in the UAE. Dan Marine Dan Marine Group is a young, rapidly growing company, with foundation company Dan Marine (Canada) Ltd.
Situated in Canada, whereas Dan Marine (Far East) Ltd. in Hong Kong, Shanghai Dan Marine I/E Co., Ltd. in PR
China, and Shanghai Marine HVAC factory. Dan Marine (Far East) Ltd. operates satellite offices in strategic Chinese coastal cities such Hong Kong, Shanghai,
Dalian, Tianjin and Guangzhou, as well as Hanoi and Haiphong in uprising ship building nation of Vietnam, aiming
primarily at agency presentation business for Marine Machinery & Equipment imported mainly from Europe. Shanghai Dan Marine I/E., Ltd. specializes in locating, distributing, and supplying of marine diesel and auxiliary
engine spare parts, deck machinery equipment, as well as general provision stores for the worldwide merchant
navy. Apart from this, she also supplies genuine replacement parts from licensee manufacturers and
subcontractors, having most of the products completed with approval from classification such as LRS, GL, ABS,
and CCS. DM Shanghai Marine HVAC Factory had been, for the past 5 years, a reputable & successful OEM supplier to as
many as 1,000 ship sets of HVAC products to the majority of Chinese ship building yards, having systems installed
on board especially those European owned export vessels. The business objective of Dan Marine is to supply good quality products at competitive prices efficiently to our
customers worldwide, along with good after sales service guaranteed to customers' satisfaction. It has always been
our aim to respond promptly to customers within 24 hours.
DMA Turnkey Case for HVAC&R Systems
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Air condition system
Prefabricated cold store system
DMA Turnkey Case for HVAC&R Systems
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Mechanical ventilation system
DMA Turnkey Case for HVAC&R Systems
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Engine room ventilation system
DMA Turnkey Case for HVAC&R Systems
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Engineering, Production, Installation, Commissioning
Marine Air Handling Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Air Handling Unit Description The MAHK marine air handling unit is the important
device to deal with the temperature and humidity of the
air in the cabin.
Normal AHU parts consist of the following sections,
which can be freely combined and mounted in casings
to form complete sections: mixing air intake, filter
section, heating section, cooling section, humidifying
section, fan section, discharge section.
Features Panel and frame: corrosion protection material,
Alu-Zinc Steel or Stainless Steel optional.
The panels are 50 mm thick and consist of a
double skinned steel sheet with intermediate
mineral wool.
Fan-motor unit: double inlet centrifugal fan, with
V-belt driven motor.
The spiroduct or square duct can be connected
directly to the sections for easy installation.
The access doors are available, which can be
opened and detached easily for inspection and
servicing.
The functional sections are optional for customers,
and meet the most demanding requirements.
Cooling medium: refrigerant (R404A, R407C,
R134A, R22 etc.) or chilled water
Heating medium: steam, hot water, hot oil, or
electric heating
Humidifying medium: Steam, fresh water +
compressed air, or fresh water
50/60 Hz, 3 phase.
Air handling unit type MAHK
Marine Air Handling Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
AHU type Item MAHK 1006 1009 1406 1409 1413 1909 1911 1913 1916
m3/s 0.43 0.68 0.69 1.09 1.68 1.65 2.09 2.54 3.29 Min
m3/h 1548 2448 2484 3924 6048 5940 7524 9144 11844
m3/s 1.29 2.03 1.90 2.98 4.61 4.28 5.45 6.62 8.56
Air flow
Max
m3/h 4644 7308 6840 10728 16596 15408 19620 23832 30816
Min KW 12 18 18 29 45 44 56 68 88 Cooling capacity
Max KW 100 157 147 231 358 332 423 513 664
Min KW 12 18 19 29 45 45 56 69 89 Heating capacity
Max KW 97 152 142 223 345 321 408 496 641
Humidifying Capacity Max kg/h 45 71 66 104 161 149 190 231 299
Max External Static pres. Pa 1440 3180 1230 3190 3290 2930 3200 3100 2480
Max Fan size 250 315 280 355 450 400 500 560 630
Max Motor Power KW 6.33 12.7 8.6 17.3 17.3 21.3 34.5 42.6 42.6 Centrifugal
Fan
Max Motor size 132S 160M 132S 160L 200L 180M 200L 200L 200L
Cooling medium(1) R404A (R407C /R134A/R22/other second refrigerant)
Heating medium(1) Steam, hot water, or electric
Humidifying medium(1) Steam, fresh water + compressed air, or fresh water
Power Supply 3Ph, 440/380 V, 60/50Hz
Normal design condition:
Summer: Inside temperature 27℃, relative humidity 50%; outside temperature 35℃, relative humidity 70%;
Winter: Inside temperature 22℃, relative humidity 50%; outside temperature -20℃;
Fresh air rate: 0~100%;
Room supply temperature 17℃ for summer, and 40℃ for winter.
Other design is available on request (refrigerant, static pressure etc.)
Marine Air Handling Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions
AHU type
MAHK W H L5) H1 C C1 D G E K
WeightApprox
kg
1006 1027 1384 2457 667 300 100 800 113.5 183.5 100 1400
1009 1027 1634 2937 917 400 200 800 113.5 258.5 1450
1406 1417 1384 2617 667 300 100 1200 108.5 183.5 1001) 1450
1409 1417 1634 2777 917 400 200 1200 108.5 258.5 130 1500
1413 1417 2034 3257 1317 700 300 1200 108.5 308.5 1550
1909 1947 1634 2857 917 400 200 1700 123.5 258.5 1550
1911 1947 1834 2857 1117 500 200 1700 123.5 308.5 1302) 1600
1913 1947 2184 3017 1317 700 300 1700 123.5 308.5 1303) /130 1650
1916 1947 2484 3177 1617 900 300 1700 123.5 358.5 1303)
/2504) 1700
1) Extension, for motor size 160M. 3) Extension, for small fan.
2) Extension, for motor size 200L and large fan. 4) Extension, for large fan. 5) The length is just one solution from all possible arrangements for guidance, and other possibilities are available.
Unit (mm)
Marine Water-cooled Condensing Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Water-cooled Condensing Unit Description The marine condensing unit consists of compressor,
oil separator, condenser, filter, sight glass, shut-off
valve, and control panel.
Three types of unit are available including direct drive,
V-belt drive and semi-hermetic.
The unit is easily connected with air-handling unit by
refrigerant line and control wiring.
The unit is delivered completed with all internal wiring,
junction box and piping, directly ready for use, and
painted on requirements.
Features
Refrigerant: R404A, R407C, R134A, R22 etc. Compressor: open or semi-hermetic type; piston
or screw type optional. Capacity control: step or stepless. Condenser: Bitzer (Germany), shell and tube type,
with high efficiency and good corrosion protection. System valves: Danfoss (Denmark), reliable and
durable. High-class painted for marine application. Control type: classical control or PLC. 50/60 Hz, 3 phase.
Condensing unit with direct drive and semi-hermetic type
Marine Water-cooled Condensing Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 1.1
Unit type Cooling capacity Length Width Height Weight
Fresh water cooled with open type compressor kw mm mm mm Approx kg
MCU-4P.2/K573H 46 1400 700 1500 500
MCU-4N.2/K813H 58 1400 700 1500 550
MCU-4H.2/K1053H 75 1800 850 1500 650
MCU-4G.2/K1353T 87 1800 850 1500 750
MCU-6H.2/K1973T 116 1800 850 1700 900
MCU-6G.2/K1973T 139 1800 850 1700 950
MCU-6F.2/K2923T 162 1800 850 1700 1000
MCU-FX16/K2923T 191 1800 850 1700 1150
Normal design condition:
Fresh water 36℃, condensing temp. 45℃, evaporating temp. 5℃. Refrigerant: R404A ( R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
Technical data 1.2
Unit type Cooling capacity Length Width Height Weight
Sea water cooled with open type compressor kw mm mm mm Approx kg
MCU-4P.2/K813HB 52 1400 700 1500 500
MCU-4N.2/K1053HB 64 1800 850 1500 550
MCU-4H.2/K1353TB 81 1800 850 1500 650
MCU-4G.2/K1353TB 93 1800 850 1500 750
MCU-6H.2/K1973TB 122 1800 850 1700 900
MCU-6G.2/K1973TB 145 1800 850 1700 950
MCU-6F.2/K2923TB 168 1800 850 1700 1000
MCU-FX16/K2923TB 203 1800 850 1700 1150
Normal design condition: Sea water 32℃, condensing temp. 42℃, evaporating temp. 5℃. Refrigerant: R404A ( R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
Marine Water-cooled Condensing Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 2.1
Unit type Cooling capacity Length Width Height Weight kw Fresh water cooled with
semi-hermetic compressor 50Hz 60Hz mm mm mm Approx kg
MCU-4P-15.2/K813H 41 52 1400 700 1500 450 MCU-4N-20.2/K813H 46 58 1400 700 1500 450 MCU-4J-22.2/K1053H 52 64 1800 850 1500 550 MCU-4H-25.2/K1053H 64 75 1800 850 1500 550 MCU-4G-30.2/K1353T 70 87 1800 850 1500 600 MCU-6J-33.2/K1353T 81 99 1800 850 1500 650 MCU-6H-35.2/K1973T 93 110 1800 850 1700 750 MCU-6G-40.2/K1973T 110 128 1800 850 1700 750 MCU-6F-50.2/K2923T 132 151 1800 850 1700 800
MCU-8GC-60.2/K2923T 156 188 1800 850 1700 850 MCU-8FC-70.2/K3803T 185 223 2000 950 1900 1050
MCU-HSK7461-80/K3803T 219 265 2000 950 1900 1050
Normal design condition: Fresh water 36℃, condensing temp. 45℃, evaporating temp. 5℃. Refrigerant: R404A ( R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
Technical data 2.2
Unit type Cooling capacity Length Width Height Weight
kw Sea water cooled with semi-hermetic compressor 50Hz 60Hz
mm mm mm Approx kg
MCU-4P-15.2/K813HB 46 52 1400 700 1500 450 MCU-4N-20.2/K1053HB 52 64 1800 850 1500 550 MCU-4J-22.2/K1053HB 58 70 1800 850 1500 550 MCU-4H-25.2/K1353TB 64 75 1800 850 1500 600 MCU-4G-30.2/K1353TB 75 93 1800 850 1500 600 MCU-6J-33.2/K1973TB 87 104 1800 850 1700 750 MCU-6H-35.2/K1973TB 99 116 1800 850 1700 750 MCU-6G-40.2/K1973TB 116 139 1800 850 1700 750 MCU-6F-50.2/K2923TB 139 162 1800 850 1700 800
MCU-8GC-60.2/K2923TB 166 200 1800 850 1700 850 MCU-8FC-70.2/K3803TB 197 237 2000 950 1900 1050
MCU-HSK7461-80/K3803TB 232 280 2000 950 1900 1050
Normal design condition: Sea water 32℃, condensing temp. 42℃, evaporating temp. 5℃. Refrigerant: R404A ( R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
Marine Water-cooled Deck Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Water-cooled Deck Unit Description The MDUK marine deck unit is specially designed for
marine installations for air conditioning. Deck Unit type
MDUK is combined with AHU and CU (Condensing
Unit) mounting under the AHU.
All operation of unit including start/stop and adjustment
of set points can be done via the control panel and
control equipment itself. The control panel is located
on deck unit under AHU or beside the unit in AC room.
After connection to cooling water and power supply,
the unit is ready for operation.
Features Refrigerant: R404A, R407C, R134A, R22 etc.
Compressor: open or semi-hermetic type; piston
or screw type optional.
Capacity control: step or stepless.
Condenser: Bitzer (Germany), shell and tube type,
with high efficiency and good corrosion protection.
System valves: Danfoss (Denmark), reliable and
durable.
High-class painted for marine application.
Control type: classical control or PLC.
50/60 Hz, 3 phase.
Water-cooled deck unit type MDUK
Marine Water-cooled Deck Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
DU type Item MDUK 1006/Q* 1009/ Q* 1406/ Q* 1409/ Q* 1413/ Q* 1909/ Q* 1911/ Q* 1913/ Q* 1916/ Q*
m3/s 0.43 0.68 0.69 1.09 1.68 1.65 2.09 2.54 3.29 Min
m3/h 1548 2448 2484 3924 6048 5940 7524 9144 11844
m3/s 1.29 2.03 1.90 2.98 4.61 4.28 5.45 6.62 8.56 Air flow
Max m3/h 4644 7308 6840 10728 16596 15408 19620 23832 30816
Min KW 12 18 18 29 45 44 56 68 88 Q*/ Cooling capacity Max KW 100 157 147 231 358 332 423 513 664
Min KW 12 18 19 29 45 45 56 69 89 Heating capacity Max KW 97 152 142 223 345 321 408 496 641
Humidifying Capacity Max kg/h 45 71 66 104 161 149 190 231 299
Max External Static pres. Pa 1440 3180 1230 3190 3290 2930 3200 3100 2480
Max Fan size 250 315 280 355 450 400 500 560 630
Max Motor Power KW 6.33 12.7 8.6 17.3 17.3 21.3 34.5 42.6 42.6 Centrifugal
Fan Max Motor
size 132S 160M 132S 160L 200L 180M 200L 200L 200L
Type Semi-hermetic or open type
Energy reg. 0, 50, 100% or 0, 33%, 66%, 100% Compressor Motor Motor power KW 34.5 51.8 51.8 2x51.8 2x51.8 2x51.8 2x63.0 2x86 2x104
Type Water-cooled shell and tube
Water flow (Max )m3/h 29.2 63.3 42.1 2x42.1 2x63.3 2x63.3 2x83.5 2x83.5 2x106.9
Max pres. drop Bar 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38
Condenser
Max Connection G2 DN65 DN65 2xDN65 2xDN65 2xDN65 2xDN100 2xDN100 2xDN100
Cooling medium R404A (R407C /R134A/R22/other second refrigerant)
Heating medium Steam, hot water, or electric
Humidifying medium Steam, fresh water + compressed air, or fresh water
Power Supply 3Ph, 440/380 V, 60/50Hz
Normal design condition:
Summer: Inside temperature 27℃, relative humidity 50%; outside temperature 35℃, relative humidity 70%;
Winter: Inside temperature 22℃, relative humidity 50%; outside temperature -20℃;
Fresh air rate: 0~100%;
Room supply temperature 17℃ for summer, and 40℃ for winter;
Evaporating temperature 5℃, condensing temperature 45℃ for fresh water cooled type,
and condensing temperature 42℃ for sea water cooled type.
Sea water inlet temperature 32℃, fresh water inlet temperature 36℃.
Other design is available on request (refrigerant, static pressure etc.).
“Q” is defined as cooling capacity, and the detailed data of Q shall be attached at the end of DU Type.
Marine Water-cooled Deck Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions
DU type
MDUK W H L5) H1 H2 S C C1 D G E K
WeightApprox
kg
1006 1027 1547 2894 667 800 100 300 100 800 113.5 183.5 100 1900
1009 1027 1797 3374 917 800 100 400 200 800 113.5 258.5 2200
1406 1417 1667 3054 667 900 100 300 100 1200 108.5 183.5 1001) 2500
1409 1417 1917 3214 917 900 100 400 200 1200 108.5 258.5 130 2800
1413 1417 2317 3694 1317 900 100 700 300 1200 108.5 308.5 3300
1909 1947 1917 3294 917 900 100 400 200 1700 123.5 258.5 3300
1911 1947 2117 3294 1117 900 100 500 200 1700 123.5 308.5 1302) 3600
1913 1947 2317 3534 1317 900 100 700 300 1700 123.5 308.5 1303) /130 3900
1916 1947 2617 3774 1617 900 100 900 300 1700 123.5 358.5 1303)
/2504) 4200
1) Extension, for AHU motor size 160M. 3) Extension, for AHU small fan.
2) Extension, for AHU motor size 200L and large fan. 4) Extension, for AHU large fan.
5) The length is just one solution from all possible arrangements for guidance, and other possibilities are available.
Unit (mm)
Marine Water-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Water-cooled Packaged Air Conditioner Description The water-cooled packaged air conditioner is specially
designed for marine application, such as engine
control room, workshop, switchboard room, galley etc.,
which consists of air handling unit, cooling unit, control
unit, built on a common framework.
The unit has been factory tested (including pressure
test, vacuum test, running test.), and the client can use
it after connecting power source and cooling water
system.
Features
● Refrigerant: R404A, R407C, R134A, R22 etc.
● Compressor: Hermetic piston type.
● Condenser: Bitzer (Germany), shell and tube type,
with high efficiency and good corrosion protection.
● System valves: Danfoss (Denmark), reliable and
durable.
● V-belt driven fan-motor, ensuring low noise level
and low vibration
● Synthetic resin powder for steel casing for marine
application.
● Cooling or heating temperature is auto setting and
displaying on control panel, remote control is
optional.
● Control type: classical control.
● 50/60 Hz, 3 phase.
Water-cooled packaged air conditioner
Marine Water-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 1 (for R404A or R22)
Type Vertical deck mount type
Plenum supply SCU–P3VR /SCU–P3VF
SCU–P5VR /SCU–P5VF
SCU–P8VR /SCU–P8VF
SCU–P10VR /SCU–P10VF Model
Duct supply SCU–D3VR /SCU–D3VF
SCU–D5VR /SCU–D5VF
SCU–D8VR /SCU–D8VF
SCU–D10VR /SCU–D10VF
Main power source (Control) AC440V x 3P x 60Hz (AC220V x 1P x 60Hz) AC380V x 3P x 50Hz (AC220V x 1P x 50Hz)
Safety protective device High pressure, low pressure, over load, lack phase, lack cooling water, over temperature, safety valve
Normal ref. ton (cooling) 3.0 USRT 5.0 USRT 7.5 USRT 10.0 USRT 10.4 Kw 17.4 Kw 26.1 Kw 34.8 Kw
Cooling capacity (water cooled) 9,000 Kcal/h 15,000 Kcal/h 22,500 Kcal/h 20,000 Kcal/h
9 Kw 12 Kw 15 Kw 20 Kw Heating capacity (electric heater)
7,759 Kcal/h 10,345 Kcal/h 12,931 Kcal/h 17,241 Kcal/h Refrigerant R-404A (R22) Casing & coating Steel & Synthetic resin powder coating
Type Hermetic reciprocating compressor 50Hz 3.7 Kw 5.6 Kw 8.1 Kw 12.1 Kw Fresh
water 60Hz 4.0 Kw 6.5 Kw 9.7 Kw 12.7 Kw 50Hz 3.7 Kw 5.4 Kw 7.7 Kw 10.0 Kw
Compressor Motor power Sea
water 60Hz 3.8 Kw 6.3 Kw 9.5 Kw 9.3 Kw Type Horizontal shell & tube type
50Hz Fresh water 60Hz
50Hz
Water flow rate Sea
water 60Hz
3.0 M3/H 7.0 M3/H 8.0 M3/H 9.0 M3/H Condenser
Pressure drop 9 KPa 25 KPa 25 KPa 9 KPa Type Crossed fin and tube type
Tube Copper Evaporator Material
Fin Aluminum (without fresh air) / Copper (with fresh air) Type Double inlet centrifugal blower
R 30 CMM/1800 M3/H 45 CMM/2700 M3/H 65 CMM/3900 M3/H 90 CMM/5400 M3/HP
F 11 CMM/660 M3/H 15 CMM/900 M3/H 22.5 CMM/1350 M3/H 30 CMM/1800 M3/HR 30 CMM/1800 M3/H 45 CMM/2700 M3/H 65 CMM/3900 M3/H 90 CMM/5400 M3/H
Air volume
D F 11 CMM/660 M3/H 15 CMM/900 M3/H 22.5 CMM/1350 M3/H 30 CMM/1800 M3/H
P 150 Pa Static pressure D 500 Pa
R 0.37/0.43 Kw 0.55/0.63 Kw 0.75/0.86 Kw 1.1/1.27 Kw P 50Hz/60Hz F 1.1/1.27 Kw 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw
R 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw 4.0/4.6 Kw
Blower
Motor power D
50Hz/60Hz F 1.1/1.27 Kw 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw Condenser inlet DN25 DN25 DN25 DN50 Condenser outlet DN25 DN25 DN25 DN50 Piping
Connection Drain G3/4 G3/4 G3/4 G3/4
Refrigerant control Thermostatic expansion valve Air filter Nonwoven cotton / synthetic blend media, G4 Colour As per maker’s standard or client’s requirement Spare part V-belt, gaskets of condenser
Marine Water-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 2 (for R407C)
Type Vertical deck mount type
Plenum supply SCU–P3VR /SCU–P3VF
SCU–P5VR /SCU–P5VF
SCU–P8VR /SCU–P8VF
SCU–P10VR /SCU–P10VF Model
Duct supply SCU–D3VR /SCU–D3VF
SCU–D5VR /SCU–D5VF
SCU–D8VR /SCU–D8VF
SCU–D10VR /SCU–D10VF
Main power source (Control) AC440V x 3P x 60Hz (AC220V x 1P x 60Hz) AC380V x 3P x 50Hz (AC220V x 1P x 50Hz)
Safety protective device High pressure, low pressure, over load, lack phase, lack cooling water, over temperature, safety valve
Normal ref. ton (cooling) 3 USRT 4.5 USRT 7.0 USRT 9.5 USRT
10.4 Kw 15.8 Kw 24.6 Kw 33.3 Kw Cooling capacity (water cooled)
9,000 Kcal/h 13,600 Kcal/h 21,200 Kcal/h 28,800 Kcal/h
9 Kw 12 Kw 15 Kw 20 Kw Heating capacity (electric heater)
7,759 Kcal/h 10,345 Kcal/h 12,931 Kcal/h 17,241 Kcal/h
Refrigerant R-407C
Casing & coating Steel & Synthetic resin powder coating
Type Hermetic reciprocating compressor
50Hz 3.2 Kw 4.7 Kw 6.9 Kw 9.9 Kw Fresh water 60Hz 3.5 Kw 4.9 Kw 7.2 Kw 11.0 Kw
50Hz 3.1 Kw 4.5 Kw 6.7 Kw 9.7 Kw
Compressor Motor power Sea
water 60Hz 3.3 Kw 4.8 Kw 7.0 Kw 10.9 Kw
Type Horizontal shell & tube type
50Hz Fresh water 60Hz
50Hz
Water flow rate Sea
water 60Hz
8.0 M3/H 10.0 M3/H 16.0 M3/H 20.0 M3/H Condenser
Pressure drop 30 KPa 35 KPa 25 KPa 25 KPa
Type Crossed fin and tube type
Tube Copper Evaporator Material
Fin Aluminum (without fresh air) / Copper (with fresh air)
Type Double inlet centrifugal blower
R 30 CMM/1800 M3/H 45 CMM/2700 M3/H 65 CMM/3900 M3/H 90 CMM/5400 M3/HP
F 11 CMM/660 M3/H 15 CMM/900 M3/H 22.5 CMM/1350 M3/H 30 CMM/1800 M3/H
R 30 CMM/1800 M3/H 45 CMM/2700 M3/H 65 CMM/3900 M3/H 90 CMM/5400 M3/HAir volume
D F 11 CMM/660 M3/H 15 CMM/900 M3/H 22.5 CMM/1350 M3/H 30 CMM/1800 M3/H
P 150 Pa Static pressure D 500 Pa
R 0.37/0.43 Kw 0.55/0.63 Kw 0.75/0.86 Kw 1.1/1.27 Kw P 50Hz/60Hz F 1.1/1.27 Kw 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw
R 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw 4.0/4.6 Kw
Blower
Motor power D
50Hz/60Hz F 1.1/1.27 Kw 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw
Condenser inlet DN25 DN25 DN50 DN50
Condenser outlet DN25 DN25 DN50 DN50 Piping Connection
Drain G3/4 G3/4 G3/4 G3/4
Refrigerant control Thermostatic expansion valve
Air filter Nonwoven cotton / synthetic blend media, G4
Colour As per maker’s standard or client’s requirement
Spare part V-belt, gaskets of condenser
Marine Water-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Note:
P: Plenum supply type, D: Duct supply type. R: Duct supply type with return air, F: Duct supply type with 100%
fresh air
Sea water inlet temperature 32℃, fresh water inlet temperature 36℃
Normal design: evaporating temperature 5℃, condensing temperature 45℃ for fresh water cooled type, and
condensing temperature 42℃ for sea water cooled type
Other design is available on request (refrigerant, static pressure etc.)
Principal dimensions 1
For Plenum type
PAC type for Plenum
L mm
W mm
H mm
Weight Approx kg
SCU-P3VR /SCU-P3VF 1000 600 1900 300
SCU-P5VR /SCU-P5VF 1100 650 2000 350
SCU-P8VR /SCU-P8VF 1200 700 2100 400
SCU-P10VR /SCU-P10VF 1400 750 2200 450
Marine Water-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions 2
For Duct connection type
PAC type for Duct connection
L mm
W mm
H mm
Weight Approx kg
SCU-D3VR /SCU-D3VF 1000 600 1640 280
SCU-D5VR /SCU-D5VF 1100 650 1740 320
SCU-D8VR /SCU-D8VF 1200 700 1840 360
SCU-D10VR /SCU-D10VF 1400 750 1890 400
Marine Air-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Air-cooled Packaged Air Conditioner Description The air-cooled packaged air conditioner is specially
designed for offshore application, and other locations
such as engine control room, workshop, switchboard
room, galley etc., which consists of indoor unit and
outdoor unit.
Indoor unit mainly consistes of air handling unit, and
control unit including operation panel.
Outdoor unit is mainly condensing unit, including
compressor, oil separator, air-cooled condenser,
condensing pressure regulator, receiver, filter, sight
glass, shut-off valve, liquid separator etc.
The PAC unit has been factory tested (including
pressure test, vacuum test, running test.), and the
client can use it after connecting refrigeration line, and
power source.
Features
● Refrigerant: R404A, R407C, R134A, R22 etc.
● Compressor: Semi-hermetic piston type.
● Condenser: crossed copper-fin and copper-tube
type, with high efficiency and good corrosion
protection.
● System valves: Danfoss (Denmark), reliable and
durable.
● V-belt driven fan-motor, ensuring low noise level
and low vibration.
● Synthetic resin powder for steel casing for marine
application.
● Cooling or heating temperature is auto setting and
displaying on control panel, remote control is
optional.
● Control type: classical control.
● 50/60 Hz, 3 phase.
Air-cooled packaged air conditioner
Indoor unit Outdoor unit (top fan)
for type P/D8V & 10V Outdoor unit (side fan)
for type P/D3V & 5V
Marine Air-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data (for R404A or R22, R407C)
Type Vertical deck mount type
Plenum supply SCU–P3VRA /SCU–P3VFA
SCU–P5VRA /SCU–P5VFA
SCU–P8VRA /SCU–P8VFA
SCU–P10VRA /SCU–P10VFA Model
Duct supply SCU–D3VRA /SCU–D3VFA
SCU–D5VRA /SCU–D5VFA
SCU–D8VRA /SCU–D8VFA
SCU–D10VRA /SCU–D10VFA
Main power source (Control) AC440V x 3P x 60Hz (AC220V x 1P x 60Hz) AC380V x 3P x 50Hz (AC220V x 1P x 50Hz)
Safety protective device High pressure, low pressure, over load, lack phase, over temperature, safety valve
Normal ref. ton (cooling) 3.0 USRT 5.0 USRT 7.5 USRT 10.0 USRT
10.4 Kw 17.4 Kw 26.1 Kw 34.8 Kw Cooling capacity (water cooled)
9,000 Kcal/h 15,000 Kcal/h 22,500 Kcal/h 30,000 Kcal/h
9 Kw 12 Kw 15 Kw 20 Kw Heating capacity (electric heater)
7,759 Kcal/h 10,345 Kcal/h 12,931 Kcal/h 17,241 Kcal/h
Refrigerant R-404A (R22, R407C)
Casing & coating Steel & Synthetic resin powder coating
Type Semi-hermetic reciprocating compressor
50Hz 4.0 Kw 6.6 Kw 9.4 Kw 11.8 Kw Compressor Motor power
60Hz 4.1 Kw 6.4 Kw 9.5 Kw 11.6 Kw
Type Air-cooled crossed fin and tube type
Tube Copper Material
Fin Aluminum (e-coating) or Copper
50Hz 2x0.16 Kw 2x0.48 Kw 2x0.82 Kw 2x1.05 Kw
Condenser (air-cooled)
Fan motor power 60Hz 2x0.18 Kw 2x0.48 Kw 2x0.82 Kw 2x1.05 Kw
Type Crossed fin and tube type
Tube Copper Evaporator Material
Fin Aluminum (without fresh air) / Copper (with fresh air)
Type Double inlet centrifugal blower
R 30 CMM/1800 M3/H 45 CMM/2700 M3/H 65 CMM/3900 M3/H 90 CMM/5400 M3/HP
F 11 CMM/660 M3/H 15 CMM/900 M3/H 22.5 CMM/1350 M3/H 30 CMM/1800 M3/H
R 30 CMM/1800 M3/H 45 CMM/2700 M3/H 65 CMM/3900 M3/H 90 CMM/5400 M3/HAir volume
D F 11 CMM/660 M3/H 15 CMM/900 M3/H 22.5 CMM/1350 M3/H 30 CMM/1800 M3/H
P 150 Pa Static pressure D 500 Pa
R 0.37/0.43 Kw 0.55/0.63 Kw 0.75/0.86 Kw 1.1/1.27 Kw P 50Hz/60Hz F 1.1/1.27 Kw 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw
R 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw 4.0/4.6 Kw
Blower
Motor power D
50Hz/60Hz F 1.1/1.27 Kw 1.5/1.73 Kw 2.2/2.53 Kw 3.0/3.45 Kw
Condenser inlet DN25 DN25 DN25 DN50
Condenser outlet DN25 DN25 DN25 DN50 Piping Connection
Drain G3/4 G3/4 G3/4 G3/4
Refrigerant control Thermostatic expansion valve
Air filter Nonwoven cotton / synthetic blend media, G4
Colour As per maker’s standard or client’s requirement
Spare part V-belt
Marine Air-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Note:
P: Plenum supply type, D: Duct supply type. R: Duct supply type with return air, F: Duct supply type with 100%
fresh air.
Cooling air inlet temperature 35℃.
Normal design: evaporating temperature 5℃, condensing temperature 50℃.
Other design is available on request (refrigerant, static pressure etc.).
Principal dimensions 1 (Indoor unit)
For Plenum type
PAC type of Indoor for Plenum
L mm
W mm
H mm
Weight Approx kg
SCU-P3VRA(I) /SCU-P3VFA(I) 1000 600 1900 300
SCU-P5VRA(I) /SCU-P5VFA(I) 1100 650 2000 350
SCU-P8VRA(I) /SCU-P8VFA(I) 1200 700 2100 400
SCU-P10VRA(I) /SCU-P10VFA(I) 1400 750 2200 450
Marine Air-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions 2 (Indoor unit)
For Duct connection type
PAC type of Indoor for Duct connection
L mm
W mm
H mm
Weight Approx kg
SCU-D3VRA(I) /SCU-D3VFA(I) 1000 600 1640 280
SCU-D5VRA(I) /SCU-D5VFA(I) 1100 650 1740 320
SCU-D8VRA(I) /SCU-D8VFA(I) 1200 700 1840 360
SCU-D10VRA(I) /SCU-D10VFA(I) 1400 750 1890 400
Marine Air-cooled Packaged Air Conditioner
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions 2 (Outdoor unit)
PAC type Of outdoor
L mm
W mm
H mm
Weight Approx kg
SCU-P3VRA(O)/SCU-P3VFA(O) /SCU-D3VRA(O)/SCU-D3VFA(O) 1200 600 1200 500
SCU-P5VRA(O)/SCU-P5VFA(O) /SCU-D5VRA(O)/SCU-D5VFA(O) 1400 650 1400 600
SCU-P8VRA(O)/SCU-P8VFA(O) /SCU-D8VRA(O)/SCU-D8VFA(O) 1400 1027 2100 900
SCU-P10VRA(O)/SCU-P10VFA(O) /SCU-D10VRA(O)/SCU-D10VFA(O) 1400 1027 2100 1000
for type P/D3V & 5V
for type P/D8V & 10V
Marine Air-cooled Condensing Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Air-cooled Condensing Unit Description The air-cooled condensing unit is specially designed
for offshore application etc., which consists of
compressor, oil separator, air-cooled condenser,
receiver, suction line accumulator and control panel
(option). Three types of unit are available including
direct drive, V-belt drive and semi-hermetic.
The unit is easily connected with air handling unit by
refrigerant line and control wiring. The unit is delivered
completed with all internal wiring, switchboards and
piping, directly ready for use, and painted on
requirements.
Features
● Refrigerant: R404A, R407C, R134A, R22 etc.
● Compressor: open or semi-hermetic type; piston
or screw type optional.
● Capacity control: step or stepless.
● Condenser: crossed copper-fin and copper-tube
type, with high efficiency and good corrosion
protection.
● System valves: Danfoss (Denmark), reliable and
durable.
● Control type: classical control or PLC.
● 50/60 Hz, 3 phase.
Air-cooled condensing unit
Marine Air-cooled Condensing Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Unit type Cooling capacity Length Width Height Weight
kw
50Hz 60Hz mm mm mm Approx kg
MCU-4P-15.2/K60A 35 46 2000 1027 2200 1000
MCU-4N-20.2/K70A 41 52 2000 1027 2200 1050
MCU-4J-22.2/K80A 46 58 3000 1027 2200 1200
MCU-4H-25.2/K90A 58 64 3000 1027 2200 1250
MCU-4G-30.2/K110A 64 75 3000 1027 2200 1400
MCU-6J-33.2/K120A 75 87 3300 1417 2200 1500
MCU-6H-35.2/K140A 87 104 3300 1417 2200 1600
MCU-6G-40.2/K160A 99 116 3300 1417 2200 1700
MCU-6F-50.2/K190A 116 139 3000 1947 2200 1800
MCU-4G-30.2/K110A(T) 128 151 3000 1947 2200 1900
MCU-6J-33.2/K120A(T) 151 174 3000 1947 2200 2000
MCU-6H-35.2/K140A(T) 174 209 4000 1947 2200 2500
MCU-6G-40.2/K160A(T) 197 232 4000 1947 2200 2600
MCU-6F-50.2/K190A(T) 232 278 6000 1947 2200 2900
Normal design condition:
Cooling air 35℃, condensing temp. 50℃, evaporating temp. 5℃.
Refrigerant: R404A ( R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
“T” used in type means twin compressors and condensers are used on the unit.
Marine Water-cooled Chiller
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Water-cooled Chiller Description MCWS series marine water-cooled chiller with
hermetic or semi-hermetic screw compressor can
supply chilled water for marine air-conditioning
systems and other special equipments.
The unit is composed of a hermetic or semi-hermetic
screw compressor, a water-cooled shell tube
condenser, a dry-expansion evaporator, expansion
valve, filter, sight glass, shut-off valve, control box etc.
The unit has compact structure, reliable performance
and convenience for maintenance. After connecting
the power and the cooling water system, users can run
the unit easily.
Features
● Refrigerant: R407C, R134A, R404A, R22 etc.
● Compressor: hermetic or semi-hermetic screw type.
● Condenser: shell and tube type, with high efficiency
and good corrosion protection.
● System valves: Danfoss (Denmark), reliable and
durable.
● High-class painted for marine application.
● Control type: classical control or PLC.
● 50/60 Hz, 3 phase.
Marine water-cooled chiller with hermetic screw compressor
Marine water-cooled chiller with semi-hermetic screw compressor
Marine Water-cooled Chiller
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Type Screw compressor type
Fresh water type MCWS–140F MCWS–280F MCWS–420F MCWS–630F Model
Sea water type MCWS–140S MCWS–280S MCWS–420S MCWS–630S
50Hz 120 Kw 240 Kw 360 Kw 540 Kw Cooling capacity
60Hz 140 Kw 280 Kw 420 Kw 630 Kw
Type Hermetic or Semi-hermetic screw compressor
Energy reg. 0, 25%, 50%, 75%, 100%
50Hz 30 Kw 58 Kw 82 Kw 140 Kw Compressor
Motor power 60Hz 35 Kw 67 Kw 95 Kw 163 Kw
Type Horizontal shell & tube type
50Hz Fresh water 60Hz
50Hz
Coolingwater flow Sea
water 60Hz
40 M3/H 80 M3/H 120 M3/H 180 M3/H
Condenser (water
-cooled)
Pressure drop 50 KPa 50 KPa 55 KPa 55 KPa
Type Dry-expansion evaporator
50Hz Fresh water 60Hz
50Hz
Chilled water flow Sea
water 60Hz
20 M3/H 40 M3/H 60 M3/H 90 M3/H Evaporator
Pressure drop 45KPa 45 KPa 50 KPa 50 KPa
Inlet DN80 DN100 DN125 DN150 Condenser
Outlet DN80 DN100 DN125 DN150
Inlet DN65 DN80 DN100 DN125
Piping Connection
Evaporator Outlet DN65 DN80 DN100 DN125
Cooling medium R407C (R404A /R134A/R22/other second refrigerant)
Power Supply 3Ph, 440/380 V, 60/50Hz
Outside dimension (L x W x H)
mm 2200X1300x1400 2600x1400x1600 2900x1500x1700 3900x1500x2100
Weight Approx kg 2300 2800 3300 5000
Normal design condition:
Sea water inlet temperature 32℃, fresh water inlet temperature 36℃.
The inlet /outlet temperature of chilled water is 12/6 ℃.
Other design is available on request (refrigerant, cooling capacity etc.)
PLC for Marine HVAC System
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
PLC for Marine HVAC System Description Both PLC-based and classical control are two options
for marine HVAC&R products. The PLC system
integrates the monitoring and control of single unit with
one compressor/AHU and up to twin unit with two
compressors/AHUs. PLC system makes the control
more intelligent, and operation more easy.
Features ● Readout on the LCD display features:
- Air temperatures.
- Air humidity (if used).
- Discharge, suction and oil pressure of compressor.
- Alarm and warning.
- Running time for compressor and fan motor.
● PLC system is prepared to control the following:
- Air temperature sensors.
- AHU fan starter/stop for motor.
- Control of humidity system for AHU.
- Control of heating system for AHU.
- Compressor motor starter/stop.
- Compressor capacity regulation.
- Remote start/stop (optional).
- Network communications (optional).
PLC-based control panel with touch screen
Graphical display of PLC for HVAC system
Marine Water-cooled Provision Refrigeration Plant
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Water-cooled Provision Refrigeration Plant
Description The water-cooled provision refrigeration unit consists
of compressor, oil separator, condenser, receiver, filter,
sight glass, shut-off valve, suction line accumulator
and control panel.
Two types of unit are available including V-belt drive
and semi-hermetic.
The unit is easily connected with air cooler by
refrigerant line and control wiring.
The twin units are delivered complete with all internal
wiring, switchboards and piping, directly ready for use,
and painted on require.
Features
● Refrigerant: R404A, R407C, R134A, R22 etc.
● Compressor: open or semi-hermetic piston type.
● Capacity control: step control.
● Condenser: Bitzer (Germany), shell and tube type,
with high efficiency and good corrosion protection.
● System valves: Danfoss (Denmark), reliable and
durable.
● High-class painted for marine application.
● Control type: classical control or PLC.
● 50/60 Hz, 3 phase.
Water-cooled provision refrigeration unit
Marine Water-cooled Provision Refrigeration Plant
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 1.1
Technical data 1.2
Unit type Cooling capacity Length Width Height Weight
Fresh water cooled
with open type compressor kw mm mm mm Approx kg
MCU-2T.2/K033N(T) 2.5 1300 1200 1100 400 MCU-2T.2/K073N(T) 4.5 1300 1200 1100 420
MCU-2T.2/K123H(T) 5.0 1300 1200 1100 450
MCU-2N.2/K123H(T) 6.5 1300 1200 1100 450
MCU-2N.2/K203H(T) 7.0 1300 1200 1100 500
MCU-4T.2/K203H(T) 10.0 1400 1200 1100 550
MCU-4P.2/K203H(T) 11.0 1400 1350 1100 650
MCU-4P.2/K283H(T) 12.0 1400 1350 1100 650
MCU-4N.2/K283H(T) 14.5 1400 1350 1100 650
Normal design condition:
Fresh water 36℃, condensing temp. 45℃, evaporating temp. -26℃.
Refrigerant: R404A (R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
“T” used in type means twin compressors and condensers are used on the unit.
Unit type Cooling capacity Length Width Height Weight
Fresh water cooled
with open type compressor kw mm mm mm Approx kg
MCU-2T.2/K073NB(T) 4.0 1300 1200 1100 420 MC- 2T.2/K123HB(T) 5.5 1300 1200 1100 450
MCU-2N.2/K123HB(T) 6.0 1300 1200 1100 450
MCU-2N.2/K203HB(T) 7.5 1300 1200 1100 500
MCU-4T.2/K203HB(T) 9.5 1400 1200 1100 550
MCU-4T.2/K283HB(T) 11.0 1400 1200 1100 600
MCU-4P.2/K283HB(T) 12.5 1400 1350 1100 650
MCU-4P.2/K373HB(T) 13.0 1400 1350 1100 650
MCU-4N.2/K373HB(T) 15.5 1400 1350 1100 650
Normal design condition:
Fresh water 36℃, condensing temp. 45℃, evaporating temp. -26℃.
Refrigerant: R404A (R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
“T” used in type means twin compressors and condensers are used on the unit.
Marine Water-cooled Provision Refrigeration Plant
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 2.1
Technical data 2.2
Unit type Cooling capacity Length Width Height Weight
kw Fresh water cooled with
semi-hermetic compressor 50Hz 60Hz mm mm mm Approx kg
MCU-2FC-2.2/K073N(T) 1.5 2.0 1300 1200 1100 300 MCU-2CC-3.2/K123H(T) 3.0 3.5 1300 1200 1100 350
MCU-4FC-3.2/K123H(T) 3.5 4.0 1300 1200 1100 400
MCU-4EC-4.2/K203H(T) 4.0 5.0 1300 1200 1100 400
MCU-4DC-5.2/K203H(T) 5.0 6.5 1300 1200 1100 450
MCU-4VC-6.2/K203H(T) 6.5 8.0 1300 1200 1100 500
MCU-4TC-8.2/K283H(T) 8.0 9.5 1300 1200 1100 500
MCU-4PC-10.2/K283H(T) 9.5 11.5 1300 1200 1100 550
MCU-4NC-12.2/K373H(T) 11.0 13.0 1300 1200 1100 550
MCU-4J-13.2/K373H(T) 13.0 15.0 1300 1200 1100 600
Normal design condition:
Fresh water 36℃, condensing temp. 45℃, evaporating temp. -26℃.
Refrigerant: R404A (R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
“T” used in type means twin compressors and condensers are used on the unit.
Unit type Cooling capacity Length Width Height Weight
kw Sea water cooled with
semi-hermetic compressor 50Hz 60Hz mm mm mm Approx kg
MCU-2FC-2.2/K073NB(T) 1.5 2.0 1300 1200 1100 300 MCU-2CC-3.2/K123NB(T) 3.0 4.0 1300 1200 1100 350
MCU-4FC-3.2/K123HB(T) 3.5 4.5 1300 1200 1100 400
MCU-4EC-4.2/K203HB(T) 4.5 5.5 1300 1200 1100 400
MCU-4DC-5.2/K203HB(T) 5.5 7.0 1300 1200 1100 450
MCU-4VC-6.2/K203HB(T) 7.0 9.0 1300 1200 1100 500
MCU-4TC-8.2/K283HB(T) 9.0 11.0 1300 1200 1100 500
MCU-4PC-10.2/K283HB(T) 10.5 12.5 1300 1200 1100 550
MCU-4NC-12.2/K373HB(T) 12.0 14.5 1300 1200 1100 550
MCU-4J-13.2/K373HB(T) 14.0 16.5 1300 1200 1100 600
Normal design condition:
Sea water 32℃, condensing temp. 42℃, evaporating temp. -26℃.
Refrigerant: R404A (R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
“T” used in type means twin compressors and condensers are used on the unit.
Marine Air-cooled Provision Refrigeration Plant
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Air-cooled Provision Refrigeration Plant Description The air-cooled provision refrigeration unit consists of
compressor, oil separator, air-cooled condenser,
receiver, filter, sight glass, shut-off valve, suction line
accumulator and control panel.
Two types of unit are available including V-belt drive
and semi-hermetic.
The unit is easily connected with air cooler by
refrigerant line and control wiring.
The twin units are delivered complete with all internal
wiring, switchboards and piping, directly ready for use,
and painted on require.
Features
● Refrigerant: R404A, R407C, R134A, R22 etc.
● Compressor: open or semi-hermetic piston type.
● Capacity control: step control.
● Condenser: crossed copper-fin and copper-tube
type, with high efficiency and good corrosion
protection.
● System valves: Danfoss (Denmark), reliable and
durable.
● High-class painted for marine application.
● Control type: classical control or PLC.
● 50/60 Hz, 3 phase.
L w
H
Air-cooled provision refrigeration plant
Marine Air-cooled Provision Refrigeration Plant
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Unit type Cooling capacity Length Width Height Weight
kw
50Hz 60Hz mm mm mm Approx kg
MCU-2FC-3.2/K3A(T) 1.5 1.8 1500 500 1700 400
MCU-2CC-4.2/K6A(T) 2.8 3.3 1500 500 1700 440
MCU-4FC-5.2/K7A(T) 3.0 3.6 1600 550 1800 500
MCU-4EC-6.2/K8A(T) 3.7 4.5 1600 550 1800 550
MCU-4DC-7.2/K10A(T) 4.4 5.3 1600 550 1800 600
MCU-4CC-9.2/K13A(T) 5.6 6.8 1600 550 1800 650
MCU-4TC-12.2/K15A(T) 6.9 8.3 1700 600 1900 700
MCU-4PC15.2/K17A(T) 8.1 9.8 1700 600 1900 750
MCU-4NC-20.2/K20A(T) 9.3 11.2 1700 600 1900 800
MCU-4J-22.2/K25A(T) 11.3 13.3 1800 650 2000 850
MCU-4H-25.2/K28A(T) 13.1 15.3 1800 650 2000 900
Normal design condition:
Cooling air 35℃, condensing temp. 50℃, evaporating temp. -26℃.
Refrigerant: R404A ( R407C/R134A/R22/other refrigerant are available).
Special design and manufacture are available on request.
“T” used in type means twin compressors and condensers are used on the unit.
Marine Air Cooler for Cold Store
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Air Cooler for Cold Store Description The SHC marine air cooler is the important device to
deal with the temperature of the air in the cold rooms.
The unit is pre-installed with refrigeration components
such as shut-off valve, solenoid valve, expansion valve,
check valve, evaporating temperature regulator etc.
The standard fin pitch of air cooler is 6.3mm, and used
in area with room temperature between +15 ℃ and
-35℃.
Features ● Refrigerant: R404A, R407C, R134A, R22 etc.
● Fan Motor Assembly
All models use a new type of high efficiency low
consumption fan motor assembly, incorporating
internal thermal protection, IP55, insulation class F.
The fans have been statically and dynamically
balanced, fan motor assembly are wired to the unit’s
electrical box.
● Electric Defrost
The stainless steel electric heater element permits a
quick and efficient defrost of the coil. The heater
elements are connected to the unit’s electrical box. For
special and particularly aggravated conditions of
applications a heavy duty electric defrost for both the
coil and shroud is available. Electrical box: IP 55.
● Casing
The new designed casing is carefully constructed and
painted to blend with materials normally used in cold
rooms.
● Maintenance and Cleaning
Access to all internal parts can be achieved with one
tool; the grill, side panels and drip tray are easily
detached giving access to fan motor assemblies,
electric heater elements, and TEV. Furthermore, inside
the unit, a suction pressure gauge connection is
available to allow for the checking of suction pressure
and correct performance of the air cooler.
Air cooler type SHC
Marine Air Cooler for Cold Store
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 1
Technical data 2
S2HC, 1600 - 8300 W N: air defrost; E: electric defrost
Unit type
65=6.3mm fin pitch
19N65
/19E65
28N65
/28E65
38N65
/38E65
55N65
/55E65
85N65
/85E65
110N65
/110E65
Rating capacity TC=2.5℃/ΔT1=10K W 1600 2050 3300 4150 6300 8300
Air flow m3/h 1000 1000 2000 2000 3000 4000
Air through m 11.5 11.5 13.5 13.5 15 17
External surface m2 5.3 5.3 10.7 10.7 16.0 21.4
Weight kg 11 12 18 20 27 34
Fan’s number n 1 1 2 2 3 4
50Hz W 85 85 170 170 255 340 Fan’s power
60Hz W 102 102 204 204 306 408
Coil W 1830 1830 3240 3240 4620 6000
Pan W 200 200 350 350 480 650 Defrost heater 230V Pipe W 100 100 100 100 100 100
Circuit volume dm3 0.6 1.3 1.2 2.3 3.3 4.3
Inlet Φmm 10 12 12 12 12 12 Connection
Outlet Φmm 10 22 22 28 28 28
A mm 678 678 1048 1048 1418 1788 Dimension
B mm 412 412 782 782 1152 1522
S3HC, 4500 – 18000 W N: air defrost; E: electric defrost
Unit type
65=6.3mm fin pitch
59N65
/59E65
84N65
/84E65
108N65
/108E65
117N65
/117E65
174N65
/174E65
218N65
/218E65
261N65
/261E65
Rating capacity TC=2.5℃/ΔT1=10K W 4500 5900 7100 9200 11950 16100 18000
Air flow m3/h 2650 2500 2700 5300 5000 7700 7500
Air through m 16 15 16.5 19 18 21.5 20.5
External surface m2 9.6 14.4 19.2 19.2 28.8 36.1 43.3
Weight kg 26 31 33 42 49 62 67
Fan’s number n 1 1 1 2 2 3 3
50Hz W 150 150 150 300 300 450 450 Fan’s power
60Hz W 180 180 180 360 360 540 540
Coil W 2780 3730 4650 4880 6550 9490 9490
Pan W 275 275 350 480 480 720 720 Defrost heater 230V Pipe W 100 100 100 100 100 100 100
Circuit volume dm3 2.1 3.2 4.0 4.0 6.0 7.4 8.7
Inlet Φmm 12 12 12 12 16 16 16 Connection
Outlet Φmm 28 28 28 28 28 35 35
A mm 863 863 1048 1418 1418 1973 1973 Dimension
B mm 597 597 782 1152 1152 1707 1707
Marine Air Cooler for Cold Store
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions
For type S2HC
For type S3HC
Marine Prefabricated Cold Store
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Prefabricated Cold Store Description The marine prefabricated cold store, applying modular
structure, is widely used on marine and offshore
application.
Generally, the marine prefabricated cold store consists
of following scope:
Panels
The panels, used as side panel, ceiling, floor, partition
wall, usually consist of stainless steel, plywood,
polyurethane foam, precoated steel plate. The density
of panel is 40~50 kg/m3.
Three kind of thickness are available, 100mm, 120mm,
and 150mm. The serviced temperature is –60~80℃.
Doors
The doors consist of a double skinned stainless steel
sheet with intermediate reinforced polyurethane foam.
The doors usually have standard size with a free
opening of 700mm x 1850mm, and can also be
customized according to site position.
Door heater is built into the door for the cold store,
where room temperature is below 0℃.
Shelves
The shelves are made of stainless steel, including
stainless steel tray. The width of shelves is 600mm as
standard size.
Accessories
Drain holes, floor grids are standard scope of supply.
Lights, alarm buttons and ozone generator are optional
equipments according to client’s requirement.
Features ● Good insulation and corrosion resistant.
● Light weight and high strength.
● Site assembly, easily installed and detached.
● Easy maintenance, safety and long working life in
heavy duty conditions.
Prefabricated Cold Store
Marine Prefabricated Cold Store
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Note: As to panels, the visible side will be usually stainless steel, and the invisible side is precoated steel plate.
Cement ground is usually made by shipyard / ship owner.
Polyurethane foam
Precoated steel plateδ=0.7mm
Plywood δ=9mm
Stainless steel δ=0.7mm
Ceiling
Polyurethane foam
Precoated steel plateδ=0.7mm
Plywood δ=9mm
Stainless steel δ=1.0mm
Floor
Wall
Polyurethane foam
Precoated steel plateδ=0.7mm
Plywood δ=9mm
Stainless steel δ=0.7mm
Cement ground
Structure figure with material data
Marine Axial Flow Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Axial Flow Fan Description CZ series marine or navy axial fans (hereafter called
the fan) are capable of blowing air, ocean air
containing salt vapor, and corrosive air which contains
oil vapor and a small quantity of acid steam generated
by the natural evaporation of the batteries. They are
suitable for cabin air ventilating and exchanging as
well as boiler ventilation on ocean-going vessels. They
are also applicable in other suitable occasion.
The fan is designed and manufactured according to
GB/T11864-2008 《Marine Axial Fan》 and the current
《Ship Building Norms》.
Features The casing can be opened, reverse, good
anti-corrosive, strong anti-swing, vibration-proof and
shock resistant.
Structure The fan is manufactured with a built-in casing motor
structure. The impeller is directly mounted on the
motor shaft.
The impeller is made of anti-corrosive cast aluminum
alloy while the casing is made of welded common
steel.
As designed, the casing can either be made into
integral one or an open type along the axial direction,
the impeller and the motor are fixed on the movable
half of the casing so as to bring convenience for
on-the-spot repair and the replacement of its spare
parts.
The fan can be matched with marine AC motor of
380V50Hz or 440V60Hz.
Further more, the explosion-proof axial flow fan is also
available on request.
Marine axial flow fan
Marine Axial Flow Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Motor Type
Folw Rate m3/h
Total pressure
Pa
Static pressure
Pa Speed r/min Freq
Hz Power
kw Type Weight
kg
600 800
110 85
90 55 2920 50 0.25 AQ26312-H 18
CZ-20 800 1000
160 110
130 80 3500 60 20
800 1200 1400
160 140 120
140 110 90
2920 50
CZ-25 1000 1500 1700
220 200 180
200 160 130
3500 60
0.55 AQ27122-H 26
1200 1800
300 195
245 145 2920 50
CZ-30A 1400 2100
440 280
350 215 3500 60
1000 1200
295 235
235 145 2920 50
CZ-30B 1200 1400
420 330
330 215 3500 60
0.75 Y-J80L1-2-H 35
3000 4500
440 250
390 150 2920 50
CZ-35A 3600 5400
635 350
555 215 3500 60
1800 3000
410 260
360 195 2920 50
1.1 Y-J80L2-2-H
1750 0.55 Y-J801-4-H CZ-35B 1200 4500
160 290
150 200 3500
60 50 1.1 Y-J802-2-H
40
4500 6000
585 500
520 390 2920 60 1.5 Y-J90S-2-H
3000 180 150 1750 0.55 Y-J801-4-H CZ-40A 5400 7200
840 715
745 560 3500 50 2.2 Y-J90L-2-H
3000 4500
520 390
490 330 2920 50 1.5 Y-J90S-2-H
CZ-40B 3600 5400
745 560
705 480 3500 60 2.2 Y-J90L-2-H
65
6000 215 175 1460 50 1.1 Y-J90S-4-H CZ-50A 7200 310 255 1750 60 1.5 Y-J90L-4-H 78
6000 9000
685 585
625 490 2920 50 3 Y-J100L-2-H 86
CZ-50B 7200 10000
990 840
900 705 3500 60 4 Y-J112M-2-H 90
9000 12000
785 615
685 490 2920 50 4 Y-J112M-2-H 100
CZ-50C 10000 14000
1125 890
990 705 3500 60 5.5 Y-J132S1-2-H 130
9000 12000
295 235
235 145 1460 50 1.5 Y-J90L-4-H
CZ-60 10000 14000
420 330
330 215 1750 60 2.2 Y-J100L1-4-H
100
12000 15000 18000
450 370 290
390 295 200
1460 50 3 Y-J100L2-4-H 145
CZ-70A 14000 18000 21000
645 540 450
560 420 295
1750 60 5.5 Y-J132S1-4-H 165
Marine Axial Flow Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
9000 12000 15000
420 295 225
390 245 145
1460 50 2.2 Y-J100L1-4-H 170
CZ-70B 10000 14000 18000
605 420 325
560 350 215
1750 60 3 Y-J100L2-4-H 180
15000 18000 21000 24000
540 470 340 295
490 390 235 155
1460 50 4 Y-J112M-4-H 165
CZ-75 18000 21000 25000 28000
775 675 490 420
705 560 330 225
1750 60 7.5 Y-J132M-4-H 190
21000 24000 27000 30000
665 595 530 390
585 490 390 225
1460 50 7.5 Y-J132M-4-H 210
CZ-80A 25000 28000 32000 36000
960 860 765 560
840 705 560 320
1750 60 11 Y-J160M-4-H 258
18000 21000 24000 27000
550 470 400 300
490 390 295 165
1460 50 5.5 Y-J132S-4-H 200
CZ-80B 21000 25000 28000 32000
785 675 575 440
705 560 420 235
1750 60 7.5 Y-J132M-4-H 235
24000 27000 30000 33000
705 570 490 350
635 490 390 225
1460 50 7.5 Y-J132M-4-H 260
CZ-90A 28000 32000 36000 40000
1010 815 705 510
910 705 560 325
1750 60 11 Y-J160M-4-H 310
27000 30000 33000 36000
765 685 615 540
685 585 490 390
1460 50 11 Y-J160M-4-H 300
CZ-90B 32000 36000 40000 48000
1100 990 890 775
900 840 705 560
1750 60 15 Y-J160L-4-H 310
30000 33000 36000
880 815 685
785 685 540
1460 50 15 Y-J160L-4-H 331
CZ-90C 36000 39000 43000
1265 1165 980
1125 980 775
1750 60 18.5 Y-J180M-4-H 385
42000 48000 54000
725 665 605
585 490 390
1460 50 15 Y-J160L-4-H 335
CZ-100A 50000 57000 60000
1040 960 870
840 705 560
1750 60 22 Y-J180L-4-H 444
36000 39000
880 735
785 635 1460 50 15 Y-J160L-4-H 340
CZ-100B 43000 46000
1265 1060
1125 910 1750 60 22 Y-J180L-4-H 444
CZ-100C 39000 42000 48000
585 530 470
490 390 295
1460 50 11 Y-J160M-4-H 322
Marine Axial Flow Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
46000 50000 57000
840 765 675
705 560 420
1750 60 15 Y-J160L-4-H 340
36000 39000
340 295
245 195 970 50 7.5 Y-J160M-6-H 322
CZ-100D 43000 46000
490 420
350 285 1160 60 11 Y-J160L-6-H 340
42000 48000 54000 60000
580 510 470 390
490 390 315 215
970 50 15 Y-J180L-6-H 540
CZ-110A 50000 57000 65000 72000
830 735 675 560
705 560 450 315
1160 60 18.5 Y-J200L1-6-H 545
42000 48000
340 295
235 145 970 50 7.5 Y-J160M-6-H 321
CZ-110B 50000 57000
490 420
330 205 1160 60 11 Y-J160L-6-H 445
42000 48000 54000
870 805 735
785 685 585
1460 50 18.5 Y-J180M-4-H 500
CZ-110C 50000 57000 65000
1255 1155 1060
1125 990 840
1750 60 30 Y-J200L-4-H 580
60000 72000
420 340
295 155 970 50 15 Y-J180L-6-H 660
CZ-120A 72000 86000
595 490
420 225 1160 60 18.5 Y-J200L1-6-H 665
60000 72000 84000
615 575 490
520 390 245
970 50 18.5 Y-J200L1-6-H 665
CZ-120B 72000 86000
100000
890 830 705
745 560 350
1160 60 30 Y-J225M-6-H 805
72000 84000 96000
685 585 490
585 490 340
970 50 22 Y-J200L2-6-H 895
CZ-140A 86000 100000 115000
980 840 705
840 705 490
1160 60 30 Y-J225M-6-H 1013
96000 115000
490 390
340 245 970 50 22 Y-J200L2-6-H 895
CZ-140B 115000 138000
705 560
490 350 1160 60 30 Y-J225M-6-H 1013
Principal dimensions
Marine Axial Flow Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Dimensions Type
D D1 D2 L n×d
CZ-20 φ200 φ232 φ254
CZ-25 φ250 φ286 φ308 300 8 φ8
CZ-30A
CZ-30B φ300 φ345 φ375 400 8 φ12
CZ-35A
CZ-35B φ350 φ395 φ425 450 8 φ12
CZ-40A
CZ-40B φ400 φ445 φ475 500 12 φ12
CZ-50A
CZ-50B
CZ-50C
φ500 φ560 φ595 550 12 φ15
CZ-60 φ600 φ660 φ695 550 12 φ15
CZ-70A
CZ-70B φ700 φ760 φ795 700 16 φ15
CZ-75 φ750 φ820 φ860 700 16 φ19
CZ-80A
CZ-80B φ800 φ870 φ910 780 16 φ19
CZ-90A
CZ-90B
CZ-90C
φ900 φ970 φ1010 850 16 φ19
CZ-100A
CZ-100B
CZ-100C
CZ-100D
φ1000 φ1070 φ1110 900 20 φ19
CZ-110A
CZ-110B
CZ-110C
φ1100 φ1170 φ1210 1000 20 φ19
CZ-120A
CZ-120B φ1200 φ1280 φ1330 1000 20 φ24
CZ-140A
CZ-140B φ1400 φ1480 φ1530 1000 24 φ24
Marine Centrifugal Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Marine Centrifugal Fan Description CLQ series marine or navy axial fans (hereafter called
the fan) are capable of blowing air, ocean air
containing salt vapor, and corrosive air which contains
oil vapor and a small quantity of acid steam generated
by the natural evaporation of the batteries. They are
suitable for cabin air ventilating and exchanging as
well as boiler ventilation on ocean-going vessels. They
are also applicable in other suitable occasion.
The fan is designed and manufactured according to
GB/T11865-2008 《Marine Centrifugal Fan》 and the
current 《Ship Building Norms》.
Features Small size, light weight, low noise, low vibration, good
anti-corrosive, good airtight, small starting torque,
strong anti-swing, vibration-proof and shock resistant.
Structure The fan is horizontal type with direct coupling for the
motor. However, it can also be a constructed into a
vertical type. The impeller is made of riveted aluminum
alloy. It has been undergone both static and dynamic
calibrations.
Both the casing and the inlet are made of welded
common steel with airtight structure.
The fan can be matched with marine AC motor of
380V50Hz or 440V60Hz.
Further more, the explosion-proof centrifugal fan is
also available on request.
Marine centrifugal fan
Marine Centrifugal Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Motor Type
Folw Rate m3/h
Total pressure
Pa
Static pressure
Pa Speed r/min Freq
Hz Power
kw Type Weight
kg
500 800
550 540
490 390 2920 50
CLQ-15 600 960
780 645
590 470 3500 60
0.75 Y-J801-2-H 25
800 1200
600 590
490 340 2920 50
CLQ-16 960 1400
860 840
705 490 3500 60
0.75 Y-J801-2-H 26
800 1200
695 685
590 440 2920 50
CLQ-17 960 1400
1000 980
840 635 3500 60
0.75 Y-J801-2-H 27
1200 1500
810 810
635 540 2920 50 0.75 Y-J801-2-H
CLQ-18 1400 1800
1165 1165
910 775 3500 60 1.1
30
1500 2000
900 880
735 590 2920 50 1.1
Y-J802-2-H
CLQ-19 1800 2400
1295 1265
1060 840 3500 60 1.5 Y-J90S-2-H
35
800 245 195 1460 50 CLQ-20 960 350 285 1750 60 0.55 Y-J80X1-4-H 30
1500 2000
1050 1030
880 735 2920 50 1.5 Y-J90S-2-H
CLQ-20 1800 2400
1510 1480
1265 1060 3500 60 2.2 Y-J90L-2-H
42
2000 2500
1175 1165
930 785 2920 50 1.5 Y-J90S-2-H
CLQ-21 2400 3000
1685 1675
1330 1125 3500 60 2.2 Y-J90L-2-H
42
2500 3000
1275 1255
980 830 2920 50 2.2 Y-J90L-2-H 45
CLQ-22 3000 3600
1830 1805
1410 1195 3500 60 3 Y-J100L-2-H 52
2500 3000
1400 1410
1175 1080 2920 50 2.2 Y-J90L-2-H 48
CLQ-23 3000 3600
2010 2030
1685 1550 3500 60 4 Y-J112M-2-H 60
1500 2000
410 360
340 245 1460 50 0.55 Y-J80L1-4-H
CLQ-24 1800 2400
590 520
490 350 1750 60 0.75 Y-J80L2-4-H
40
3000 4000
1635 1560
1370 1080 2920 50 3 Y-J100L-2-H 45
CLQ-24 3600 4800
2350 2235
1970 1550 3500 60 5.5 Y-J132S1-2-H 75
2000 2500
430 430
340 295 1460 50 0.75 Y-J80L2-4-H
CLQ-25 2400 3000
670 640
540 440 1750 60 1.1 Y-J90S-4-H
44
4000 1910 1570 2920 50 4 Y-J112M-2-H 74 CLQ-25 4800 2745 2255 3500 60 7.5 Y-J132S2-2-H 105 2500 3000
510 510
390 340 1460 50 1.1 Y-J90S-4-H
CLQ-27 3000 3600
735 735
560 490 1750 60 1.5 Y-J90L-4-H
48
Marine Centrifugal Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
2500 3000
625 570
540 440 1460 50 1.1 Y-J90S-4-H
CLQ-29 3000 3600
860 810
775 635 1750 60 1.5 Y-J90L-4-H
63
3000 4000
645 635
540 440 1460 50 1.5 Y-J90L-4-H 65
CLQ-30 3600 4800
930 910
775 635 1750 60 2.2 Y-J100L1-4-H 73
4000 5000
745 735
590 490 1460 50 2.2 Y-J100L1-4-H 75
CLQ-32 4800 6000
1070 1060
840 705 1750 60 3 Y-J100L2-4-H 77
4000 5000
920 795
685 590 1460 50 2.2 Y-J100L1-4-H 78
CLQ-33 4800 6000
1185 1135
990 840 1750 60 3 Y-J100L2-4-H 80
5000 6000
860 840
685 590 1460 50 3 Y-J100L2-4-H 81
CLQ-34 6000 7200
1235 1215
990 840 1750 60 4 Y-J112M-4-H 94
5000 6000 7200
970 930 870
830 735 590
1460 50 4 Y-J112M-4-H 77
CLQ-36 6000 7200 8600
1390 1330 1255
1195 1060 840
1750 60 5.5 Y-J132S-4-H 99
6000 7200
1010 990
830 735 1460 50 4 Y-J112M-4-H 102
CLQ-37 7200 8600
1450 1420
1195 1060 1750 60 5.5 Y-J132S-4-H 124
6000 490 340 970 50 CLQ-39 7200 705 490 1160 60 2.2 Y-J112M-6-H 105
7200 9000
1185 1090
980 785 1460 50 5.5 Y-J132S-4-H 132
CLQ-39 8600 10800
1705 1560
1410 1125 1750 60 7.5 Y-J132M-4-H 147
5000 6000
1215 1175
1080 980 1460 50 4 Y-J112M-4-H 106
CLQ-40 6000 7200
1745 1685
1550 1410 1750 60 7.5 Y-J132M-4-H 143
6000 7200
590 540
490 390 970 50 2.2 Y-J112M-6-H 116
CLQ-42 7200 8600
840 775
705 560 1160 60 3 Y-J132S-6-H 139
9000 12000
1305 1285
1080 880 1460 50 7.5 Y-J132M-4-H 158
CLQ-42 10800 14000
1870 1840
1550 1265 1750 60 11 Y-J160M-4-H 211
7200 9000
635 600
490 390 970 50 3 Y-J132S-6-H 142
CLQ-44 8600 10800
910 860
705 560 1160 60 4 Y-J132M1-6-H 152
9000 12000
1480 1450
1275 980 1460 50 11 Y-J160M-4-H 214
CLQ-44 10800 14000
2130 2090
1830 1410 1750 60 15 Y-J160L-4-H 232
9000 675 490 970 50 4 Y-J132M1-6-H 158 CLQ-46 10800 970 340 1160 60 5.5 Y-J132M2-6-H 173 12000 15000
1610 1500
1275 980 1460 50 15 Y-J160L-4-H 220
CLQ-46 14000 18000
2310 2155
1830 1410 1750 60 18.5 Y-J180M-4-H 292
CLQ-48 9000 12000
735 655
590 390 970 50 4 Y-J132M1-6-H 161
Marine Centrifugal Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
10800 14000
1060 940
840 560 1160 60 5.5 Y-J132M2-6-H 177
12000 15000
1735 1695
1470 1275 1460 50 15 Y-J160L-4-H 241
CLQ-48 14000 18000
2490 2440
2120 1830 1750 60 22 Y-J180L-4-H 245
12000 775 540 970 50 5.5 Y-J132M2-6-H 181 CLQ-50 14000 1110 775 1160 60 7.5 Y-J160M-6-H 221 15000 18000
1830 1795
1470 1275 1460 50 18.5 Y-J180M-4-H 246
CLQ-50 18000 21000
2635 2580
2120 1830 1750 60 22 Y-J180L-4-H 350
12000 15000
930 850
735 540 970 50 7.5 Y-J160M-6-H 231
CLQ-52 14000 18000
1330 1225
1060 775 1160 60 11 Y-J160L-6-H 255
15000 940 685 970 50 7.5 Y-J160M-6-H 242 CLQ-54 18000 1350 990 1160 60 11 Y-J160L-6-H 266 15000 18000
1060 1010
830 685 970 50 11 Y-J160L-6-H 277
CLQ-56 18000 21000
1520 1440
1195 980 1160 60 15 Y-J180L-6-H 372
18000 1155 880 970 50 15 Y-J180L-6-H 383 CLQ-58 21000 1655 1265 1160 60 18.5 Y-J200L1-6-H 388 Principal dimensions
Marine Centrifugal Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Type A A1 A2 A3 B B1 B2 B3 D1 D2 D3 n1xd1 n2xd2 H h h1 h2 M M 1 L L1 L2 L3 L4 4-K
CLQ-15 105 159 135 60 135 188 165 80 ф209 ф185 ф156 8 ф10 8 ф10 314 80 124.5 95.5 270 125.5 392 87 105.5 100 125 4 ф10 CLQ-16 110 165 140 70 150 203 180 90 ф223 ф200 ф170 8 ф10 8 ф10 338 80 132.5 104 290.5 134 401 92 108.5 100 125 4 ф10 CLQ-17 110 165 140 70 150 203 180 90 ф223 ф210 ф180 8 ф10 8 ф10 338 80 132.5 104 290.5 134 401 92 108.5 100 125 4 ф10 CLQ-18 125 180 155 80 155 208 185 100 ф243 ф218 ф190 8 ф10 8 ф10 358 80 142.5 111.5 310 143.5 416 100 116 100 125 4 ф10 CLQ-19 140 195 175 80 180 233 215 120 ф253 ф235 ф200 8 ф10 10 ф10 398 90 158.5 123 340.5 154 452 108.5 129.5 100 140 4 ф10
80 432 123.5 100 125 4 ф10 CLQ-20 140 195 175 80 180 233 215 120 ф263 ф245 ф210 8 ф10 10 ф10 398 90
158.5 123 340.5 154477
108.5129.5 125 140 4 ф10
CLQ-21 145 210 180 90 190 253 225 140 ф283 ф255 ф220 8 ф10 10 ф10 437 90 171.5 139 370 166.5 486 115 132 125 140 4 ф10 90 489 134.5 125 140 4 ф10 CLQ-22 150 215 190 90 210 273 245 160 ф293 ф265 ф230 8 ф10 10 ф10 459
100180.5 142 395 180.5
519115
141.5 140 160 4 ф12 90 506 142 125 140 4 ф10 CLQ-23 165 230 200 100 215 278 250 160 ф303 ф275 ф240 8 ф10 10 ф10 469 112
185.5 144.5 410 190.5556
125156 140 190 4 ф12
80 476 142.5 100 125 4 ф10 100 551 155.5 140 160 4 ф12 CLQ-24 175 243 210 100 225 291 260 170 ф314 ф285 ф250 8 ф10 10 ф12 498 132
196 156.5 429 195626
133181.5 140 216 4 ф12
80 506 153.5 100 140 4 ф10 112 581 167.5 140 190 4 ф12 CLQ-25 185 263 220 110 250 325 285 190 ф334 ф295 ф260 8 ф12 10 ф12 521 132
203 155 448 205736
138186.5 140 216 4 ф12
CLQ-27 200 275 235 120 250 325 285 190 ф353 ф330 ф280 8 ф12 10 ф12 558 90 221.5 175 481.5 220 552 153 160 125 140 4 ф10 CLQ-29 210 286 255 150 270 344 310 200 ф374 ф339 ф300 8 ф12 12 ф12 587 90 234 181 510 234 559 155 165 125 140 4 ф10
90 569 170 125 140 4 ф10 CLQ-30 220 296 265 160 280 354 320 210 ф384 ф349 ф310 8 ф12 12 ф12 607 100
242 188 535 249600
160177 140 160 4 ф12
CLQ-32 230 306 275 170 300 374 340 210 ф404 ф370 ф330 8 ф12 12 ф12 649 100 259 203 565 258 609 165 182 140 160 4 ф12 CLQ-33 240 316 282 170 310 384 350 210 ф414 ф380 ф340 8 ф12 12 ф12 663 100 266 205 580 266 619 170 187 140 160 4 ф12
100 629 192 140 160 4 ф12 CLQ-34 250 326 295 180 325 399 365 220 ф424 ф389 ф350 8 ф12 12 ф12 695 112
278 217.5 610 280649
175199 140 190 4 ф12
112 769 209 140 190 4 ф12 CLQ-36 270 346 315 210 340 414 380 260 ф444 ф410 ф370 12 ф12 12 ф12 727 132
292 228 635 289724
185228 140 216 4 ф12
112 679 209 140 190 4 ф12 CLQ-37 270 346 315 210 360 434 400 270 ф454 ф420 ф380 12 ф12 12 ф12 751 132
300 234 650 292724
185228 140 216 4 ф12
112 689 219 140 190 4 ф12 132 744 238 140 216 4 ф12 CLQ-39 290 366 335 230 370 444 410 280 ф474 ф440 ф400 12 ф12 12 ф12 784.5 132
312.5 250 674.5 300784
195238 178 216 4 ф12
112 669 209 140 190 4 ф12 CLQ-40 270 346 315 210 340 414 380 260 ф474 ф440 ф400 12 ф12 12 ф12 769 132
313 349 680 313765
185229 178 216 4 ф12
112 719 234 140 190 4 ф12 132 784 253 140 216 4 ф12
CLQ-42 320 396 365 270 400 475 440 340 ф505 ф470 ф430 12 ф12 12 ф12 844
132
340.5 266 735.5 331
814
210
253 178 216 4 ф12
Marine Centrifugal Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
160 889 272 210 254 4 ф15 132 784 253 140 216 4 ф12 132 814 253 178 216 4 ф12 160 889 272 210 254 4 ф15
CLQ-44 320 396 363 270 420 495 460 350 ф525 ф490 ф450 12 ф12 12 ф12 878
160
353.5 277 765.5 344
934
210
272 254 254 4 ф15 132 814 253 178 216 4 ф12 132 814 253 178 216 4 ф12 160 889 272 210 254 4 ф15
CLQ-46 320 396 363 270 440 515 480 360 ф545 ф510 ф470 12 ф12 12 ф12 915
180
371.5 286.5 800 360
954
210
285 241 279 4 ф15 132 850 269 178 216 4 ф12 132 850 269 178 216 4 ф12 160 970 288 254 254 4 ф15
CLQ-48 350 438 399 290 450 536 495 370 ф586 ф550 ф500 12 ф12 12 ф12 966
180
391 307 840 377
1005
230
301 279 279 4 ф15 132 860 274 178 216 4 ф12 160 985 293 210 254 4 ф15 160 998 293 254 254 4 ф15
CLQ-50 360 448 408 290 470 556 515 390 ф606 ф570 ф520 12 ф12 12 ф12 992
180
402 312 870 394
1015
235
306 279 279 4 ф15 955 303 210 254 4 ф15 CLQ-52 380 468 428 310 480 566 525 400 ф626 ф590 ф540 12 ф12 12 ф12 1036 160 422 331 910 412
1000245
303 254 254 4 ф15 960 303 210 254 4 ф15 CLQ-54 380 468 428 310 530 616 576 450 ф646 ф610 ф560 12 ф12 12 ф12 1078 160 441 329 935 416
1005250
303 254 254 4 ф15 160 1025 313 254 254 4 ф15 CLQ-56 400 488 448 330 540 626 586 460 ф666 ф630 ф580 12 ф12 12 ф12 1106 180
453 340 975 4421060
260326 279 279 4 ф15
180 1080 336 279 279 4 ф15 CLQ-58 420 508 468 350 560 646 606 480 ф686 ф650 ф600 12 ф12 12 ф12 1152 200
474 355 1010 4541155
270348 318 305 4 ф15
Duct Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Duct Fan Description
High capacity and reliability:
In-line centrifugal duct fan, type CK, is a
straight-through radial fan. It is compact, with a high
capacity and very easy to install. The CK fan can cope
with high pressure and long duct runs, whilst still
operating at an acceptable sound level. The fan speed
can be controlled by voltage or frequency variation
regulators. Several fans can be connected to the same
controller providing the total nominal current of the
fans does not exceed the rating of the controller. The
CK ranges of fans are moisture resistant and are
approved for installing in humid or damp environments.
The fans are rated IP44 when installed in a duct
system. They must not be used for transporting
grinding dust, soot or similar. The casing is
manufactured from pre-galvanized steel. Automatic
thermo-contacts open if the temperature within the
motor windings becomes excessive.
Accessories:
Duct clamps, mounting brackets, back-draught
shutters, louver shutters, safety grills and speed
controllers.
Duct fan
Duct Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 1 (for 50Hz)
Duct Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data 2 (for 60Hz)
Duct Fan
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Principal dimensions
Cabin Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Cabin Unit Description Cabin Unit is the terminal device of the air conditioning
system, which are applicable for the lodging cabins,
dining halls, offices, meeting rooms and so on in the
vessels, which can also be used as the terminal device
of the hotels, hospitals, large meeting halls, etc. Cabin
unit type CUS for Single-Pipe System, type CUR for
Re-Heat System and type CUT for Twin-Pipe System,
are available for different application. Basically, the cabin unit is made up of 3 parts:
Attenuator box
Made with Al-Zinc or antimagnetic Al thin steel
plates, laid inside with fire proof and damp proof
rock wool as the sound absorption and insulation
material
Air flow regulating device
Provided with the primary air flow limit and the
secondary air flow adjustment. The former can
balance the air flow of all cabin units, while the
secondary air flow adjustment knob is used for
the manual adjustment of the air flow
Diffuser
The diffuser of the pan type cabin unit is pressed
to form with steel. The diffuser of ball type cabin
unit is made with stainless steel and polished
outside, set with the adjustment knob to adjust
the air flow and air direction conveniently.
Features
Compact structure and easily installation on the
ceiling
The diffuser is either in the pan type or the ball
type
Single pipe and twin pipe air inlet for the cabin
unit are available
Auxiliary electric heating devices can also be
added to the above types of cabin units.
Materials
Attenuator box: Al-Zinc steel
Diffuser of pan type: Steel
Diffuser of ball type: stainless steel
Cabin Unit type CUS, CUR Cabin Unit type CUT
Cabin Unit
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
Type Cabin unit /
Diffuser A
(mm) B
(mm) C
(mm) X
(mm)Air flow (m3/h)
Electric heating (W)
Weight (Kg)
Power Voltage
Item no. Cabin unit / Diffuser
CUS-25 / C 450 135 80 55-70 0-250 0 10.0 N/A ZZ7000 / ZZ7006
CUS-25 / N 450 135 80 80-95 0-250 0 10.0 N/A ZZ7016 / ZZ7007
CUS-35 / C 600 175 100 55-70 0-350 0 12.5 N/A ZZ7001 / ZZ7006
CUS-35 / N 600 175 100 80-95 0-350 0 12.5 N/A ZZ7017 / ZZ7007
CUR-25 / C 552 135 80 55-70 0-250 400,800,1200 12.0 1x220V ZZ7004 / ZZ7006
CUR-35 / C 690 175 100 55-70 0-350 400,800,1200 16.0 1x220V ZZ7005 / ZZ7006
Type Cabin unit / Diffuser
A (mm)
B (mm)
C (mm)
D (mm)
X (mm)
Air flow (m3/h)
Weight (Kg)
Item no. Cabin unit / Diffuser
CUT-25 / C 450 135 80 80 55-70 0-250 10.0 ZZ7002 / ZZ7006
CUT-35 / C 600 175 100 80 55-70 0-350 12.5 ZZ7003 / ZZ7006
Dimension sketch CUS, CUR
Diffuser C Diffuser N
Dimension sketch CUT
Diffuser C Diffuser N
Galley Canopy
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Galley Canopy Description The galley canopy type GCK, mounted above the
hearth, is used to remove large volume of air with
smoke or steam in the galley. The filters of canopy can
separate oil and gas, and the oil collected can be
drained away through drain hole on canopy.
Features
● The case is made of stainless steel.
● The filter is made of meshwork of stainless steel,
and can be remove for washing easily.
● The light is as optional accessories on request.
● Other design is available on request.
Principal dimensions
Air Washer
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Air Washer Description The air washer type AWK, is widely used to clean the
dust air on transporting cargoes, which usually
transport sand, cement and corn and so on. The air for
ventilation has to be purified to avoiding dust damage
to machinery installation on ship.
The air washer mainly consists of stainless steel case,
frame, atomizing nozzle group, droplet separator,
drain pan.
By spraying seawater with atomizing nozzles, the dirt
of the air will be washed out. The processed air will
pass through the rear droplet separator finally, and the
rest of droplet will be eliminated.
Features
● The panels of air washer are stainless steel with
2mm thickness.
● The atomizing nozzle is stainless steel with
corrosion free.
● The access door is available on the operation side
for service and inspection.
● The air washer is available with H x W (Height x
Width) from 600 x 600 mm to 2000 x 2000 mm at
intervals of 200 mm, and other dimension are
available on request.
Air washer type AWK
Air Washer
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Technical data
mm W= 600 800 1000 1200 1400 1600 1800 2000
Airflow m3/h 5760 7920 H=600
Water flow m3/h 7.0 9.0
Airflow m3/h 7920 10440 12960 H=800
Water flow m3/h 9.0 11.0 12.5
Airflow m3/h 12960 16200 19440 H=1000
Water flow m3/h 12.5 15.0 17.0
Airflow m3/h 19440 23400 27360 H=1200
Water flow m3/h 17.0 19.5 21.0
Airflow m3/h 27360 31680 36000 H=1400
Water flow m3/h 21.0 22.5 25.0
Airflow m3/h 36000 41400 46800 H=1600
Water flow m3/h 25.0 27.5 29.0
Airflow m3/h 46800 52560 58320H=1800
Water flow m3/h 29.0 31.0 33.5
Airflow m3/h 58320 64800H=2000
Water flow m3/h 33.5 35.0
Principal dimensions
Contact Global DMA
www.dma-marine.com DMA reserves the right to change design or specification without prior notice.
Worldwide Locations/Representation
DM Alscott Marine Offshore HVAC Ltd. Shanghai factory. Add: No. 1551 Dong Sheng Road, Pudong, Shanghai China, 201201 上海浦东东胜路 1551 号 Tel: 0086 21 68916603, 68916605 Fax: 0086 21 68916607 Email: [email protected]
Sales office: Canada:
Ottawa 1127 River Road, Ottawa, ON, K4M 1B4 Tel:+1 6138257092 Email: [email protected] Halifax 120 Joseph Zatsman Drive, Dartmouth, N.S. B3B 1B4 Tel: +1 9024687080 Email [email protected] Vancouver 2825 SW Marine Drive, Vancouver, BC V6N 3Y1 Tel : +1 6046351070 Fax: +1 6046351010
______________________________________________ United States
2714 Windy Thicket Lane, Houston, Texas, USA Tel: (0)2812369173 Email: [email protected]
The Bahamas
Fishing Hole Road, Freeport, Grand Bahamas Tel: (0)2423504066 Email: [email protected]
______________________________________________ China
Hong Kong #1206, C.C Wu Building, 302-308 Hennessy Rd, WanchaiTel: +852-21470874 Fax: +852-21470133 Shanghai #1101 Dongfang Mansion, 1500 Century Avenue, PudongTel:+86 21 6164 2298 Fax: +86 21 6164 2200 Dalian #1530, Changjiang Office Building, 123 Changjiang RoadTel: +86 411 8252 9442 Fax: +86 411 8252 9443 Tianjin Tel: +86 22 2579 2522 Fax: +86 22 2579 2522 Guangzhou Tel: +86 20 6236 1341 Fax:+86 20 6236 1342 Emai; [email protected] or [email protected]
Vietnam. Tel: +84 31 356 9178 Fax: +84 31 356 9179
Agent for sales and service in the world: Greece & Cyprus:
Alpha Marine Engineering Ltd (AME) 43,Salaminos str. 16674 Glyfada Athens-Greece Tel: +302108943220 Fax: +30-2109680210 Website: www.ame.gr
_____________________________________________Norway:
HVAC Engineering A/S Hanabryggene Teknologisenter Hanaveien 4, N-4327Sandnes Norway Tel: +47 51 67 10 50 Fax : +47 51 67 10 51 Website: www.hvac.as
_____________________________________________Germany
Karberg & Schmifz Gmbh Pamaile 112 22767 Hamburg Germany Tel: +49 40386 0040 Fax:+49 40389 5097 Website: www.karberg-schmitz.de
_____________________________________________India:
Arcum Engineering (P) Ltd. 76, Udyog Bhavan, Sonawala Road Goregaon (E),Mumbai,- 400063, India Tel: +91 22 26864427 Fax:+91 22 26864229 Website: www.arcumonline.com
_____________________________________________USA:
American United Marine Corp. 35 Congress St. Suite 214 Salem, MA 01970-7312 Tel: 1-9787412862 Fax: 1-9787417776 Website: www.aumcorp.com
_____________________________________________Singapore:
Scanjet Asia Pacific Pte. Ltd. Tel: +(65) 96703438 Email: [email protected] Website: www.scanjet.se