DISTRICT HEATING SUBSTATIONS AMARC DHS DESIGNS AND MANUFACTURES A COMPLETE RANGE OF PRODUCTS TO SATISFY ALL NEEDS OF DISTRICT HEATING AND COOLING. DISTRICT HEATING SUBSTATIONS PED

District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

District Heating substationsA m A r c D H S D e S i g n S A n D m A n u fA c t u r e S A c o m p l e t e r A n g e o f p r o D u c t S

t o S At i S f y A l l n e e D S o f D i S t r i c t H e At i n g A n D c o o l i n g .

DISTRICT HEATING SUBSTATIONS

PED

Page 2: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

2

The company was established in 1998, under the name of Amarc tecnologie, its aim being to harness the considerable experience gained in the industrial heating and process control industry since 1950, and to consolidate and turn this expertise into reproducible scientific and technological principles.

During this time, the company partnered leading Italian and foreign companies in developing research projects, up to the construction and installation of components, machines and plants, which also involved the registration of some international patents.

More recently, the company became involved, for some applications, in district heating - a technology which was barely known or developed, at least in Italy. After several years of testing and operations, the company decided to invest heavily in this sector, and above all in technical product and production process development, as well as in automatic control and supervision systems.

AmArc DHS: tHe compAny

WWW.AmArcDHS.it

The cover shows an image of New York, where, at the end of 1800, was installed the first district heating network.

A tribute to the origins of our industry that our company has greatly contributed to develop in Italy offering reliable products of high quality , technology and design setting the standard in the domestic and foreign markets.

Page 3: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

3

today Amarc DHS (District Heating Substations) engineers, manufactures and installs district heating substations, with a product portfolio of over 300 models, featuring standard district heating substations with a capacity from 10 to 6,000 kW, as well as remote cooling stations with a capacity from 50 to 2,500 kW, plus optionals and accessories, for one of Europe’s most extensive ranges in the industry:

•user Satellites units for central heating systems

•Single living unit wall substations from 10 to 40 kW.

•Wall Substations from 10 to 150 kW.

•Base Substations for hot and superheated water certified CE/PED, from 50 to 6.000 kW.

•Drainage Bag filters for secondary circuit and district

heating network from 15 to 40 m³/h, from PN10 to PN25, for hot and superheated water, max135°C.

•management System to optimize district heating plant, remote setting, telemetering and telecontrol for user substation.

•remote control and hardware tools for communication network specific for district heating plants.

More than 10 years of experience in the industry have created a management and optimisation computer system that can integrate network and substation requirements and functions in one software application, which can make all the difference in terms of profitability for district heating systems.

WWW.AmArcDHS.it

AmArc DHS: tHe compAny

Page 4: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

4

satBASE | satPLUS | satDESIGN | satINCASSO MonoBASE | MonoPLUSMonoDESIGN | MonoINCASSO

• 18÷35 kW for heating and 10÷50 kW for domestic hot water (DHW).

• Versions: base, plus, incasso and design.

• Equipped with ultrasonic heat meter compliant with EN 1434/MID, setting and security organs.

• Connected to district heating substation and boilers.

• PN 10 for 1° circuit.

• Individual setting and accounting management.

• Production of instantaneous domestic hot water.

• Ready for setting, telemetering and remote control.

• Remote control with thermostat.

• Streamlined and thrifty versions.

• Small dimension.

• 18÷40 kW for heating and 10÷50 kW for domestic hot water (DHW).

• Versions: base, plus, incasso and design.

• Equipped with ultrasonic heat meter compliant with EN 1434/MID, setting and security organs.

• PN 25 for 1° circuit.

• For hot and superheated water network.

• For heating and domestic hot water.

• Automatic group load.

• Remote control with thermostat.

• Big expansion vase.

• Certified CE/PED.

• Ready for setting, telemetering and remote control.

• Setting for flow rate limitation, power and return temperature.

• Regulation of fixed-point temperature or compensated outdoor temperature.

ultrA compAct uSer SAtelliteS ultrA compAct Single liVing unit WAll SuBStAtionS

10÷5

0 kW60

0

150500

800

500150 10

÷50

kW

Page 5: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

5

• 10÷60 kW for heating in standard configuration and max 180 kW for domestic hot water (DHW).

• Equipped with ultrasonic heat meter compliant with EN 1434/MID, setting and security organs.

• PN 25 for 1° circuit.

• For hot and superheated water network.

• For heating or domestic hot water.

• Customizable.

• Certified CE/PED.

• Ultra compact dimension.

• Ready for setting, telemetering and remote control.

• Setting for flow rate limitation, power and return tempera-ture.

• Regulation of fixed-point temperature or compensated outdoor temperature.

• Easy to upkeep.

• 30÷150 kW for heating in standard configuration and max 180 kW for domestic hot water (DHW).

• Equipped with ultrasonic heat meter compliant with EN 1434/MID, setting and security organs.

• PN 25 for 1° circuit.

• For hot and superheated water network.

• For heating and/or domestic hot water.

• Customizable.

• Certified CE/PED.

• Compact dimension.

• Ready for setting, telemetering and remote control.

• Setting for flow rate limitation, power and return tempera-ture.

• Regulation of fixed-point temperature or compensated outdoor temperature.

• Easy to upkeep.

boLZanoBASE | boLZanoPLUSboLZanoINCASSO

FonDoD.H.W. | FonDoHEATINGFonDoCOMBI

ultrA compAct WAll SuBStAtionSSingle AnD multiple liVing unit Single AnD multiple liVing unit

compAct WAll SuBStAtionS

600

500

150 10÷8

0 kW 92

5

750260 30

÷180

kW

Page 6: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

6

• 50÷5,000 kW for heating in standard configuration.

• Equipped with ultrasonic heat meter compliant with EN 1434/MID, setting and security organs.

• PN 25 for 1° circuit.

• Version with double heat exchanger (max 5,000 kW).

• For hot and superheated water network.

• Version for cooling, heating or DHW.

• Customizable.

• Certified CE/PED.

• Small dimension.

• Designed for disassembly.

• Ready for setting, telemetering and remote control.

• Setting for flow rate limitation, power and return temperature.

• Regulation of fixed-point temperature or compensated outdoor temperature.

• 50÷6,000 kW for heating in standard configuration.

• Equipped with ultrasonic heat meter compliant with EN 1434/MID, setting and security organs.

• PN 25 for 1° circuit.

• Version with double heat exchanger (max 6,000 kW).

• For hot and superheated water network.

• Version for cooling, heating or DHW.

• Customizable.

• Certified CE/PED.

• Small dimension.

• Designed for disassembly.

• Ready for setting, telemetering and remote control.

• Setting for flow rate limitation, power and return temperature.

• Regulation of fixed-point temperature or compensated outdoor temperature.

MiLanoC-S-D torinoC-S-DVareseC-S-D

gASKeteD plAte HeAt eXcHAnger BASe SuBStAtionSBrAZeD HeAt eXcHAnger BASe SuBStAtionS

1650

-213

0

1800-2980

600-1450

1650

-183

5

1500-2300

500-1450

50 ÷

5.0

00 k

W

50 ÷

6.0

00 k

W

Page 7: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

7

• 1° and 2° circuit easy to be cleaned.

• Temporary or permanent installation.

• Work to make efficient the heat exchanger and reduce costs.

• 15÷40 m³/h.

• PN 10÷PN 25.

• For hot and superheated water network. Max 135°C.

• 4 filtration levels (Super Soft, Soft, Medium, Hard) mini-mum 0,5 micron.

• Measuring system to manage pressure and stoppage.

• Remote signal for maximum dirt level.

• Certified CE/PED.

• Volume: 20-55-80 liter

• In/out: DN65-DN80-DN100

• 50÷2,500 kW with brazed and gasketed plate exchanger.

• Equipped with cooling meter, setting and security organs.

• PN 25 for 1° circuit.

• Version with double exchanger (max 2500 kW).

• For district cooling network.

• Customizable.

• Certified CE/PED.

• Small dimension.

• Designed for disassembly.

• Ready for setting, telemetering and remote control.

• Setting for flow rate limitation, power and return temperature.

• Regulation of fixed-point temperature or compensated outdoor temperature.

bieLLabieLLaD

coLognoC-S

BAg filterSDiStrict cooling netWorK BASe SuBStAtionS

50 ÷

2.5

00 k

W

15 -

25 -

40 m

³/h

1650

-210

0

1800-3050

870-1900

Page 8: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

8

• Management system to manage, set and optimize district heating system.

• Automatic telemeter of thermal energy use.

• Substations remote control.

• Monitoring ∆p in significant points.

• By-pass valve management and control.

• Pumping units management and optimization for district heating power plant.

• Management and monitoring alarms.

• Continuous monitoring of network parameters, data storage and trend management.

• Invoice with customized forms.

• Programmable PID regulator.

• Daily and weekly schedule with time slots setting.

• Perpetual calender with automatic mamagement of summer time clock change (BST) and leap year.

• 20 typologies of schemes already preloaded.

• Setting with compensation criterion base on external temperature.

• Possibility to activate antifreeze, antilimestone, antilegionella functions.

• Suitable for many type of thermal probes.

• Contemporary management of flow rate limit, power and temperature at 1° circuit.

• Management of circulator and single or tween pump.

• Ready for remote control via Meter-Bus.

aVD500 Libero500

progrAmmABle piD regulAtor mAnAgement SoftWAre for DiStrict HeAting SyStem

Page 9: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

9

Hot Water suPerHeateD Water cooLing Direct

D.H.W.inDirect

D.H.W.

PriMarY circuit tHerMaL ProJect 90/65°C 115/65°C 7/11°C 85/55°C 85/55°C

seconDarY circuit tHerMaL ProJect 60/75°C 60/75°C 14/8°C 25/50°C 30/55°C

Loss oF LoaD (∆p) at noMinaL conDition 1° anD 2° circuit

< 10 w.c.m. (1°)< 3 w.c.m. (2°)

< 10 w.c.m. (1°)< 3 w.c.m. (2°)

< 15 w.c.m. (1°)< 6 w.c.m. (2°)

< 10 w.c.m. (1°)< 3 w.c.m. (2°)

< 10 w.c.m. (1°)< 3 w.c.m. (2°)

exchanger with adjustable feet

electrical panel

manifold/frame unit

additional disassembly of the manifold/frame unit

exchanger with adjustable feet

electrical panel

manifold/frame unit

manifold/frame unit

1 2

3 4

TyPICAl oPERATINg CoNDITIoNS FoR DISTRICT HEATINg SUBSTATIoN

All AMARC DHS SUBSTATIoNS ARE DESIgNED AND BUIlT BASED oN DIFFERENT NEED lIKE TRANSPoRTATIoN, ASSEMBlINg AND INSTAllATIoN.

Page 10: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

10

LOCAL STATION FOR POWER PLANT MANAGEMENT

LOCAL STATION FOR NETWORK AND DISTRICT HEATING SUBSTATIONS

MANAGEMENT

REMOTE STATION FOR POWER PLANT, NETWORK

AND SUBSTATIONS MANAGEMENT

POWER PLANT GATEWAY M-BUS CONCENTRATOR

- GOVERNOR- EMBEDDED

THERMAL STORAGE SYSTEM

NETWORK AND SUBSTATIONS

GATEWAY M-BUS CONCENTRATOR

- GOVERNOR- EMBEDDED

MOBILE STATION FOR POWER PLANT, NETWORK

AND SUBSTATIONS MANAGEMENT

EXPANSION SYSTEM

PUMPING SYSTEMACCOUNTING SYSTEM REGULATION SYSTEM

REMOTE STORAGE AND PUMPING SYSTEM

SUBSTATION (MONO COMBI)HEATING AND DHW HEATING SUBSTATION

HEATING SUBSTATIONDHW (DIRECT)SUBSTATION

DHW (INDIRECT) SUBSTATION

END POINT BY-PASS+ ∆P TRANSMITTER

END POINT BY-PASS+ ∆P TRANSMITTER

ABSORBER

COOLING SUBSTATION

END POINT BY-PASS+ ∆P TRANSMITTER

APARTMENTS WITH USER SATELLITE

UNITS FOR HEATING AND DHW

INVERTER

INVERTER

INVERTER

INVERTER

Thermal cogeneration systems (also indipendent and inhomogeneous) applicable in the later stages

Power plant supervision system

Thermal storage system that also serves as hydraulic separator, using the physical phenomenon of stratification, uses the energy produced at different temperatures.

Expansion system with pressurized storage tank with optimazed capacity

Thermoregulation of network temperature indipendent from storage temperature

Pumping system able to modulate base on ΔP values through inverter with compensated set-point in network high deficit points

functionAl DiAgrAm of A DiStrict HeAting SyStem

The functional diagram of the management system so as outlined below represents the consolidation of over 10 years of experience in the design, implementation and managementof district heating plants. Using a standard design and construction facilitates all the operations related to the implementation of district heating systems like the cost of investment and the speed of embodiment, the operating cost and the certification process. It ‘s still possible to integrate existing plants or change functionality based on specific customer needs.

Page 11: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

11

LOCAL STATION FOR POWER PLANT MANAGEMENT

LOCAL STATION FOR NETWORK AND DISTRICT HEATING SUBSTATIONS

MANAGEMENT

REMOTE STATION FOR POWER PLANT, NETWORK

AND SUBSTATIONS MANAGEMENT

POWER PLANT GATEWAY M-BUS CONCENTRATOR

- GOVERNOR- EMBEDDED

THERMAL STORAGE SYSTEM

NETWORK AND SUBSTATIONS

GATEWAY M-BUS CONCENTRATOR

- GOVERNOR- EMBEDDED

MOBILE STATION FOR POWER PLANT, NETWORK

AND SUBSTATIONS MANAGEMENT

EXPANSION SYSTEM

PUMPING SYSTEMACCOUNTING SYSTEM REGULATION SYSTEM

REMOTE STORAGE AND PUMPING SYSTEM

SUBSTATION (MONO COMBI)HEATING AND DHW HEATING SUBSTATION

HEATING SUBSTATIONDHW (DIRECT)SUBSTATION

DHW (INDIRECT) SUBSTATION

END POINT BY-PASS+ ∆P TRANSMITTER

END POINT BY-PASS+ ∆P TRANSMITTER

ABSORBER

COOLING SUBSTATION

END POINT BY-PASS+ ∆P TRANSMITTER

APARTMENTS WITH USER SATELLITE

UNITS FOR HEATING AND DHW

INVERTER

INVERTER

INVERTER

INVERTER

Remote control system and telemetering for district heating substations

Absorbers for individual cooling systems or cooling substations for networks with 4 pipes.

District heating substations (for apartment building) instead of boilers for new power plants.

District heating substations (for one flat only)15-120 kW for heating and/or DHW.

District heating substations (for apartment building) instead of boilers for new power plants for direct DHW District heating

substation with user satellite units with individual accounting and thermoregulation

District heating substations (for apartment building) instead of boilers for new power plants for indirect DHW

Page 12: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

12

DISTRICT HEATING TIPICAL DIAGRAM, THERMAL POWER PLANT 15÷20.000 KW

DHW + INDIPENDENT HEATING SUBSTATIONS (CT 3)

T

DHW

M-Bus

M-Bus

M-Bus

M-Bus

M-Bus

E C

T

VETT

T

E C

T

VE

DHS 2

TT

T

E C

T

VE

DHW DHS

TT

T

VE

VE

VE

TSH PSH TSHHTM

TR

M-Bus

TSH PSH TSHHTM

TR

TSH PSH TSHHTM

TR

TSH

ΔP

DOMESTIC HOT WATER (DHW) AND HEATING SINGLE SUBSTATION (CT 2)

T

DHW DHS

T T

E C

T

M-Bus

VE

DHS

TT

T

VE

E C

T

M-Bus

VE

M-Bus

TT

T

VE

USER HEATING SYSTEM

TSH PSH TSHH

M-Bus

TM

TR

TSH PSH TSHHTM

TR

TSH

ΔP

External probe

Leakage alarm

Regulator

Regulator

Remote control thermostat

Bag �lter

Remote control thermostat

Bag �lter

Fill valve

Fill valve

expansion system

Aqueduct

expansion system

Aqueduct

D.H.W.

HEATING1 HEATING2

Existing remote control

Aqueduct

USER HEATING SYSTEM

DHS 1Bag �lter

Bag �lter

Bag �lter

Fill valve

expansion system

Aqueduct

Fill valve

expansion system

Aqueduct

Fill valve

expansion system

Aqueduct

Remote control thermostat

Remote control thermostat

Remote control thermostat

Regulator

Regulator

Regulator

External probe

External probe

Leakage alarm

HEATING1 HEATING2

Aqueduct

TyPICAl DIAgRAM FoR MUlTI USERS DISTRICT HEATINg SUBSTATIoNS, THERMAl PoWER PlANT 15÷20.000 kW

SINGLE HEATING SUBSTATION (CT 1)

TSH PSH

E C

T

T

ΔP

TM

TR

TSHH

T T

D.H.W.

M-Bus

VE

External probe

M-Bus

USER HEATING SYSTEM

TT

T

VE

DISTRICT HEATING TIPICAL DIAGRAM, THERMAL POWER PLANT 15÷20.000 KW

expansion system

Regulator Remote control thermostat

TSH

Bag �lter

Leakage alarm

Fill valve

DOUBLE HEATING SUBSTATION (CT 1A)

T

T T

VE

TSH

E C

T

M-Bus

VETT

T

E C

T

M-Bus

VE

M-Bus

TT

T

TSH PSH TSHH

M-Bus

TM

TR

TSH PSH TSHHTM

TR

Regolatoreprogrammabile

ΔP

MULTIPLE HEATING SUBSTATIONS (CT 1B)

E C

T

M-Bus

VETT

T

E C

T

M-Bus

VE

M-Bus

TT

T

TSH PSH TSHH

M-Bus

TM

TR

TSH PSH TSHHTM

TRΔP

T

Aqueduct

D.H.S.

D.H.S.1

HEATING1 HEATING2

Existing remote control

Aqueduct

D.H.W.

Aqueduct

HEATING1 HEATING2

Existing remote control

USER HEATING SYSTEM

expansion system

Fill valveAqueduct

Remote control thermostat

Regulator

External probe

Leakage alarm

Bag �lter

Remote control thermostat

D.H.S.2Bag �lter

D.H.S.1

D.H.S.n

Remote control thermostat Remote control

USER HEATING SYSTEM

External probe

External probe

Regulator

Sequencer remote control

Bag �lter

Leakage alarm

Regulator

Regulator

Remote control thermostat

Bag �lter

Page 13: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

13

TyPICAl DIAgRAM FoR DISTRICT HEATINg SySTEM oF APARTMENT BUIlDINg WITH USER SATEllITES UNIT

electric power cabinet and data concentrator

SOFTWARE TELEMETERING AND

REMOTE CONTROL

(optical �ber or cable network)Modem

Apartment 3

Apartment 2

Apartment 1

M-B

us n

etw

ork

M-Bus

M-Bus

Thermostat

M-Bus

M-Bus

M-Bus

Apartment n

Digital regulator

M-Bus

Distributionnetwork

TIPICAL DIAGRAM SAT

T P

T

E C

T

Regulator

E C

TIPICAL DIAGRAM SAT MIDI

DISTRICT HEATING SYSTEM OF APARTMENT BUILDING WITH USER SATELLITES UNIT

by-pass valve

TM

TM

TR

TR

M-B

us n

etw

ork

M-B

us n

etw

ork

M-Bus

M-Bus

30 m

30 m

Cold water

Balancing valve

Remote control thermostat

Remote control thermostat

Aqueduct

Cold water

Aqueduct

Cold water

Aqueduct

Thermostat

Cold water

Aqueduct

Aqueduct

Cold water

Remote control thermostat

Thermostat

External probe

Aqueduct

Cold water

Balancing valve

Distributionnetwork

Page 14: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

14

TyPICAl DIAgRAM FoR DISTRICT HEATINg SySTEM oF APARTMENT BUIlDINg WITH USER SUBSTATIoNS

Thermal power plant

Rete

M-B

us

M-Bus

DISTRICT HEATING SYSTEM OF APARTMENT BUILDING WITH USER SUBSTATIONS

ΔP

M-Bus

M-Bus

M-Bus

E C

T

E C

TIPICAL DIAGRAM SST MONO COMBI SUBSTATION

P

VE

T

T

T

M-Bus

TIPICAL DIAGRAM MONO SUBSTATION

House �lter (compulsory)

Rete

M-B

us

M-Bus

M-Bus

M-Bus

30 m

30 m

30 m

30 m

P TTSH TSHH

VE

TSH TSHH

TM

TM

TR

TR

Y �lter (suggested)

electric power cabinet and data concentrator

SOFTWARE TELEMETERING AND

REMOTE CONTROL

(optical �ber or cable network)Modem

Apartment 3

Apartment 2

Apartment 1

Apartment n

by-pass valve

Cold water

Remote control thermostat

Remote control thermostat

Aqueduct

Aqueduct

Aqueduct

Remote control thermostat

Remote control thermostat

Cold water

Aqueduct

External probe

External probe

Remote control thermostat

Remote control thermostat

Regulator

Regulator

Y �lter (suggested)

Aqueduct

Aqueduct

Cold water

Page 15: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

15Amarc DHS reserves the right to change this document without notice.

TyPICAl DIAgRAM FoR DISTRICT HEATINg SySTEM WITH METER BoXES

DHW Substation

HEATING Substation

E C

METER BOX DIAGRAM (CC1)

METER BOX TIPICAL DIAGRAM

SOFTWARE TELEMETERING AND

REMOTE CONTROL

MODEM (OPTICAL FIBER OR CABLE NETWORK)

ELECTRIC POWER CABINETAND DATA CONCENTRATOR

Network

Network

Network

by-pass valve

Apartment n

Apartment 3

Apartment 2

Apartment 1

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

Thermal power plant

Aqueduct

Fill valve

thermostat

DHW

Aqueduct

Aqueduct

EV

Page 16: District Heating substations · • Big expansion vase. Certified CE/PED. Ready for setting, telemetering and remote control. • Setting for flow rate limitation, power and return

Am

arc

DH

S m

akes

use

of F

SC e

co-fr

iend

ly a

nd re

cycl

ed p

aper

DH

S D

C 17

0512

DP-

EN

AmArc DHS Srl | Via F. lovati 29 | 20842 Besana Brianza (MB) Italy | [email protected] | tel +39 0362 915 857

w w w.amarcdhs. i t