60
DiscovIR- GC™

DiscovIR-GC ™

  • Upload
    foster

  • View
    28

  • Download
    0

Embed Size (px)

DESCRIPTION

DiscovIR-GC ™. The Epidemic is coming (Tucson News KOLD/KMSB). Synthetic Analog Problem. DEA Temporary Placement of JWH-018, JWH-073, JWH-200, CP47,497 and CP47,497 C8 homolog, MDPV, Mephedrone, Methylone on Schedule 1 H.R. 1254: Synthetic Drug Control Act of 2011 - PowerPoint PPT Presentation

Citation preview

Page 1: DiscovIR-GC ™

DiscovIR-GC™

Page 2: DiscovIR-GC ™

2

The Epidemic is coming (Tucson News KOLD/KMSB)

Page 3: DiscovIR-GC ™

3

Synthetic Analog Problem DEA Temporary Placement of JWH-018, JWH-073, JWH-200, CP47,497 and CP47,497 C8

homolog, MDPV, Mephedrone, Methylone on Schedule 1

H.R. 1254: Synthetic Drug Control Act of 2011

AK S 17: Classifies certain synthetic cannabinoids as schedule IIA controlled substances.

AL H 158, S 207 and S 208: Relates to schedule I controlled substances; provides legislative findings relating to controlled substance analogs; adds cathinone compounds, certain named chemical compounds of synthetic cannabinoids, and controlled substance analogs to the schedule I controlled substances list subject to regulation and penalties in the same manner as other controlled substances.

AZ S 1043: Relates to dangerous drugs; relates to definition.

AZ H 2388: Adds AM-2201 and JWH-122 to the definition of “dangerous drugs” and to schedule I. Relates to authority to define the chemical composition of controlled substances included in drug schedules; provides for authority to include chemical variations of those substances as necessary; provides consideration of a substance’s potential for abuse, pharmacological effect, current scientific knowledge and the risk to public health; requires written report; exempts the board of pharmacy from rulemaking requirements.

CA A 2420: Provides that every person who possesses, under circumstances that do not include possession for sale as proscribed pursuant to existing law, 28.5 grams or less of any synthetic cannabinoid or any synthetic stimulant compound, or any synthetic stimulant derivative is guilty of an infraction punishable by a specified fine.

HI S 1305: Adds HU-210, JWH-018, JWH-073 to controlled substances provisions.

Page 4: DiscovIR-GC ™
Page 5: DiscovIR-GC ™

5

Multiple isomers to choose from !!! A cannabinoid Example

Class 1: Classic Cannabinoid Class 2: Basic non classic Cannabinoid Class 3: Naphtoylindole

Class 4: PhenylacetylindoleClass 5: Benzoylindole

Page 6: DiscovIR-GC ™

(+-)CP 47,497 (1R,3S) or (1S,3R)

Page 7: DiscovIR-GC ™

CP47,497 Diastereomers and Homologs

Page 8: DiscovIR-GC ™

JWH-250

JWH-302

JWH-201

DiscovIR-GC

Positional Isomers

Page 9: DiscovIR-GC ™

JWH 302 vs JWH-201

Page 10: DiscovIR-GC ™
Page 11: DiscovIR-GC ™

Analysis of a K-2 Sky Sample

Page 12: DiscovIR-GC ™

Plant Extract/ Fatty Acids

Page 13: DiscovIR-GC ™

Identification of JWH-203

Page 14: DiscovIR-GC ™

JWH-237

JWH-206

JWH-018

JWH-018 1’napthyl isomer

JWH122

AM2201

AM2201 2’napthyl isomer

JWH-098

JWH-210

AM694 4-iodo isomer

JWH-022

JWH-016

JWH-020

JWH-015

JWH-007

JWH-018 adamantyl

RCS-4 C4 homolog

JWH-203

Other Cannabimimetics spectra recently acquired on the DiscovIR-GC

JWH-081

JWH-398

RCS-8

RCS-8 3-methoxy isomer

RCS-8 4-methoxy isomer

JWH-200

JWH-200 2’ napthyl isomer

AM-694

AM-694 3-iodo isomer

JWH-251

RCS-4

RCS-4 3-methoxy isomer

RCS-4 2-methoxy isomer

JWH-073

JWH-073 2’napthyl isomer

JWH-250

JWH-201

JWH-302

Page 15: DiscovIR-GC ™

DiscovIR-GC™ The Solution for Designer Drugs

Step #1 Separation by Gas Chromatography

Step #3 Chemical Identification - using FTIR specificity (positional and stereoisomers)

Step #2 Controlled Deposition - unique solid phase deposition.

GC typical

Page 16: DiscovIR-GC ™
Page 17: DiscovIR-GC ™

How does it work ?

Page 18: DiscovIR-GC ™

18

GC-IR System optics

Page 19: DiscovIR-GC ™

Polystyrene CalibrationInfrared beam

NIST Traceable polystyrene filmfor daily calibration test Acquisition of solid phase

transmission spectra through ZnSe disc

Page 20: DiscovIR-GC ™

Disc Track Pointer

End Sample 2 RT= 20.0 min

Start Sample 2 RT= 0.0 min

Records linear positionand rotary position forFor every spectra

Infrared beam fixed in position

ZnSE Disc rotatescounterclockwise

Page 21: DiscovIR-GC ™

21

Sample deposit ZnSe window

Optical path

Vacuum chamber

ABB BomemMCT

Precision Vacuum Backplate

Cryogenic LN2

IR Detector

Interferometer PCB

Page 22: DiscovIR-GC ™

Heated Transfer line

Page 23: DiscovIR-GC ™

GC-IR/MS

Page 24: DiscovIR-GC ™

24

Loading the sample disk

Page 25: DiscovIR-GC ™

25

DiscovIR VACUUM CHAMBER, (10-4 torr)

4 inch diameter ZnSe disc, washable & reusable Holds 50 hours of chromatography in spiral track Auto location, Checks for sample, Post dep. analysis

Resistive Heaters +/-5oC

Disc auto load/unload

Sample collection mechanism

Page 26: DiscovIR-GC ™

26

Data Acquisition and Instrument Control software based on Thermo GRAMS™

Page 27: DiscovIR-GC ™

27

Spectrum Trace

Spectrum Trace

Chromatogram Trace

Page 28: DiscovIR-GC ™

QA/QC / Performance Qualification

Voltage check to ensure detector is working properly

Noise check to ensure proper signal/noise ratio

NIST traceable polystyrene scan is performed

A test mix (amphetamine, phentermine, pseudoephedrine, caffeine, cocaine and alprazolam) enables :

• GC check (proper separation)• IR detector (proper identification)

Page 29: DiscovIR-GC ™

Example of a Daily Test Mix Chromatogram

Page 30: DiscovIR-GC ™

Typical Case Work Sample Preparation

Sample preparationSample can be extracted/prepared as if

analyzing via GC/MSMeOH (dilute and shoot type)Basic CHCl3, Basic Hex, Acidic CHCl3Acidic Hex

Normal GC/MS vials can be used

no real change of procedure needs to be employed

Page 31: DiscovIR-GC ™

Amphetamine mixture Chromatogram

Page 32: DiscovIR-GC ™

Amphetamine & Methamphetamine

Fingerprint Region

Page 33: DiscovIR-GC ™

MDA & MDMA

Page 34: DiscovIR-GC ™

Phentermine & Methamphetamine

Page 35: DiscovIR-GC ™
Page 36: DiscovIR-GC ™

Methamphetamine via Shake and Bake method:Analysis of a field sample by GC-IR

CMP

MethamphetaminePseudoephedrine

Page 37: DiscovIR-GC ™

Diastereomers in Meth Synthesis

Pseudoephedrine

Ephedrine

Page 38: DiscovIR-GC ™

Pseudoephedrine IR SpectrumDirect Deposition VS. Solid Phase Reference

Comparable To Solid phase/condensed phase IR spectra run with:- ATR- KBR pellet- Nujol Mull

Page 39: DiscovIR-GC ™

FTIR Specificity: Pseudoephedrine hit list

Page 40: DiscovIR-GC ™
Page 41: DiscovIR-GC ™

Emerging Threat 2C-Phenethylamines

Page 42: DiscovIR-GC ™
Page 43: DiscovIR-GC ™

Bath salt sample Analysis

Page 44: DiscovIR-GC ™

4-fluoromethcathinone overlaid with 3-fluoromethcathinone

Page 45: DiscovIR-GC ™

Solid Phase Mid-IR Spectrum of Mephedrone

Page 46: DiscovIR-GC ™

Solid Phase Mid-IR Spectrum of Lidocaine

Page 47: DiscovIR-GC ™

Solid Phase Mid-IR Spectrum of MDPV

Page 48: DiscovIR-GC ™

Presence of one Cannabinoids: JWH-018

Page 49: DiscovIR-GC ™

Advantage of Solid Phase DD GC-IR

Page 50: DiscovIR-GC ™

Sample at RT 21.9 minutesafter 600 scans

Advantage of Solid Phase DD GC-IR

Noise or Split Band?

Rescan enables increases SNR for Decision

Page 51: DiscovIR-GC ™

JWH-073 and JWH-015 isomers MW 327.4

Page 52: DiscovIR-GC ™

JWH-073 overlaid with JWH-015 isomer

Page 53: DiscovIR-GC ™

Library search of JWH-15 versus library of 40 cannabinoids results in quality score of 0.97

Page 54: DiscovIR-GC ™

Tryptamines

Page 55: DiscovIR-GC ™

Clandestine Tablets

Most clandestine tablets are mixtures

Can obtain an infrared spectra for each component

With the DB-35 column can separate BZP, TFMPP and MDMA (see figures 4-7)

Isomer determination for MDMA, TFMPP and CPP (to name just a few)

Page 56: DiscovIR-GC ™

Exhibit containing BZP, TFMPP, MDMA and Caffeine

Page 57: DiscovIR-GC ™

Clandestine Tablet: Containing BZP, TFMPP, MDMA and Caffeine

Page 58: DiscovIR-GC ™

Why use DiscovIR-GC?

Resolve and identify mixed analytes in a single instrument and procedure.

GC-FTIR provides two analytical methods in one operation. High resolution solid phase spectra Self-cleaning IR disk. No need to manually clean off old samples. Automatic operation up to 50 hours: Autosampler-compatible. Spectral identification library software. Nanogram sensitivity. Flow splitting: can interface with existing GC–MS instrumentation. Real-time or post-run data collection. Allows re-analysis of

deposited samples

Page 59: DiscovIR-GC ™

Substances Routinely Analyzed via GCIR system

Methamphetamine (includes clan lab, powder and residues)AmphetamineCodeine cough syrupHeroinMorphine (residues from spoons, straws, syringes etc)CocaineClandestine tabletsOxycodone (residues from spoons, straws, syringes, etc)Tryptamines and phenethylaminesBath Salts Cannabinoids

Page 60: DiscovIR-GC ™