17
DIMENSION AND INSTALLATION GUIDE 510mm 58mm (built-in height) 860mm A minimum B minimum 830mm 470mm Gas supply connection © 2007 Electrolux Home Products Pty Ltd WDIMGHL95/795 Current as at Jul 2007 Note: Electrical connection Requires 240V 10AMP power outlet cooktop dimensions building-in cut-out dimensions Walls around cooktop must be heat resistant for temperatures up to 90 o C to a height of 150mm above the bench top. These models are supplied with 10Amp plug and lead * Minimum height of non-combustible surface is 150mm NOTE: All appliances must be installed to Australian Standard AS5601 minimum distance to combustible vertical surface minimum distance to non-combustible vertical surface* A 135mm 50mm B 120mm 50mm gas cooktop MODELS: GHL95, GHL795

DIMENSION AND INSTALLATION GUIDE gas cooktop

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

DIMENSION AND INSTALLATION GUIDE

510mm

58mm(built-in height)

860mm

A minimumB minimum

830mm470mm

Gas supply connection

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL95/795 Current as at Jul 2007

Note: Electrical connectionRequires 240V 10AMP power outlet

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

These models are supplied with 10Amp plug and lead

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

gas cooktop

MODELS: GHL95, GHL795

DIMENSION AND INSTALLATION GUIDE

PHL222

320mm505mm

40mm(built-in height)

600mm

303mm

485mm

50mm min

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL222 Current as at Jul 2007

Note: Connection type - hardwired Maximum power load 3.0kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.

Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.

Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.

cooktop dimensions

building-in cut-out dimensions

electric ceramic cooktop

MODEL: PHL222

DIMENSION AND INSTALLATION GUIDE

600mm 535mm

58mm(built-in height)

600mm

50mm min

490mm

570mm

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL255 Current as at Jul 2007

cooktop dimensions

building-in cut-out dimensions

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles

Note: Connection type requires 240V/20A power outlet

electric solid hotplate cooktop

MODEL: PHL255

DIMENSION AND INSTALLATION GUIDE

600mm

50mm min

485mm

588mm

615mm 515mm

40mm(built-in height)

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL284 Current as at Jul 2007

Note: Connection type - hardwired Maximum power load 6.0kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.

Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.

Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.

cooktop dimensions

building-in cut-out dimensions

electric ceramic cooktop

MODEL: PHL284

DIMENSION AND INSTALLATION GUIDE

605mm 505mm

40mm(built-in height)

600mm

50mm min

485mm

588mm

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL285 Current as at Jul 2007

Note: Connection type - hardwired Maximum power load 6.4kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles

Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.

Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.

cooktop dimensions

building-in cut-out dimensions

electric ceramic cooktop

MODEL: PHL285

DIMENSION AND INSTALLATION GUIDE

605mm

95mm

505mm

505mm

40mm(built-in height)

65mm(built-in height)

600mm

50mm min

485mm

588mm

80mm120mm max.

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL564 Current as at Jul 2007

cooktop dimensions

building-in cut-out dimensions

Note: Connection type - hardwired Maximum power load 6.4kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles

Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.

Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.

control panel dimensions

electric ceramic cooktop

MODEL: PHL564

DIMENSION AND INSTALLATION GUIDE

870mm406mm

100mm(built-in height)

600mm

362mm

825mm

50mm min

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL365 Current as at Jul 2007

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles

cooktop dimensions

building-in cut-out dimensions

Note: Connection type requires 240V/20A power outlet

electric solid hotplate cooktop

MODEL: PHL365

DIMENSION AND INSTALLATION GUIDE

615mm 515mm

40mm(built-in height)

600mm

50mm min

485mm

588mm

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL668 Current as at Jul 2007

cooktop dimensions

building-in cut-out dimensions

Note: Connection type - hardwired Maximum power load 5.9kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles

Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.

Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.

electric ceramic cooktop

MODEL: PHL668

DIMENSION AND INSTALLATION GUIDE

600mm

50mm min

485mm

588mm

615mm 515mm

40mm(built-in height)

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL768 Current as at Jul 2007

cooktop dimensions

building-in cut-out dimensions

Note: Connection type - hardwired Maximum power load 6.5kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles

Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.

Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.

electric ceramic cooktop

MODEL: PHL768

DIMENSION AND INSTALLATION GUIDE

930mm440mm

50mm(built-in height)

600mm

50mm min

360mm

870mm

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL394 Current as at Jul 2007

Note: Connection type - hardwired Maximum power load 6.2kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.

cooktop dimensions

building-in cut-out dimensions

electric ceramic cooktop

MODEL: PHM394U

DIMENSION AND INSTALLATION GUIDE

600mm

50mm min

462mm

880mm

896mm505mm

50mm(built-in height)

© 2007 Electrolux Home Products Pty Ltd

WDIMPHL798 Current as at Jul 2007

cooktop dimensions

building-in cut-out dimensions

Note: Connection type - hardwired Maximum power load 6.5kW

Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.

electric ceramic cooktop

MODEL: PHM798

DIMENSION AND INSTALLATION GUIDE

535mm

58mm(built-in height)

600mm

A minimum

B minimum

570mm

490mm

Gas supply connection

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

Note: Electrical connectionGHL12 models require a 240V/10A power outlet.GHL11 models do not require an electrical connection.

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL11/12 Current as at Jul 2007

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

GHL12 is supplied with 10Amp plug and lead

gas cooktop

MODELS: GHL11, GHL12

DIMENSION AND INSTALLATION GUIDE

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

535mm

58mm(built-in height)

600mm

A minimum

B minimum

570mm

490mm

Gas supply connection

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL16/17/765 Current as at Jul 2007

Note: Electrical connectionRequires 240V 10AMP power outlet

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

These models are supplied with 10Amp plug and lead

gas cooktop

MODELS: GHL16, GHL17, GHL765

DIMENSION AND INSTALLATION GUIDE

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

542mm

58mm(built-in height)

600mm

A minimum

B minimum

570mm

490mm

Gas supply connection

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL26 Current as at Jul 2007

Note: Electrical connectionRequires 240V 10AMP power outlet

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

These models are supplied with 10Amp plug and lead

gas cooktop

MODEL: GHL26

DIMENSION AND INSTALLATION GUIDE

520mm

58mm(built-in height)

890mm

A minimumB minimum

830mm470mm

Gas supply connection

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL46 Current as at Jul 2007

Note: Electrical connectionRequires 240V 10AMP power outlet

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

These models are supplied with 10Amp plug and lead

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

gas cooktop

MODEL: GHL46

DIMENSION AND INSTALLATION GUIDE

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

510mm

58mm(built-in height)

860mm

A minimumB minimum

830mm470mm

Gas supply connection

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL90 Current as at Jul 2007

Note: Electrical connectionNot required

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

gas cooktop

MODEL: GHL90

DIMENSION AND INSTALLATION GUIDE

* Minimum height of non-combustible surface is 150mm

NOTE: All appliances must be installed to Australian Standard AS5601

minimum distance to combustible vertical surface

minimum distance to non-combustible vertical surface*

A 135mm 50mm

B 120mm 50mm

58mm(built-in height)

510mm

860mm

A minimumB minimum

830mm470mm

Gas supply connection

© 2007 Electrolux Home Products Pty Ltd

WDIMGHL92 Current as at Jul 2007

Note: Electrical connectionRequires 240V 10AMP power outlet

cooktop dimensions

building-in cut-out dimensions

Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.

These models are supplied with 10Amp plug and lead

gas cooktop

MODEL: GHL92