1 Digital Radiology for Corrosion Inspection Uwe Zscherpel, Uwe Ewert, BAM Berlin Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK May 2011, Bodo, Norway 1 Application „on stream“ Content: - basic principles of TRT - software for evaluation and documentation - corrosion depth evaluation - validation of methods - development of standards Digital Radiology for Corrosion Inspection and Wall Thickness Measurement of Insulated Pipes AGFA, GE S&IT, HOIS, IAEA Digital Radiology for Corrosion Inspection Uwe Zscherpel, Uwe Ewert, BAM Berlin Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK May 2011, Bodo, Norway 2 Corrosion Erosion Corrosion and Seads Projection Radiography Examples on Corrosion and Erosion

Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

Embed Size (px)

Citation preview

Page 1: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

1

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway1

Application „on stream“

Content: - basic principles of TRT- software for evaluationand documentation

- corrosion depth evaluation- validation of methods- development of standards

Digital Radiology forCorrosion Inspectionand Wall ThicknessMeasurement ofInsulated Pipes

AGFA, GE S&IT, HOIS,IAEA

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway2

Corrosion ErosionCorrosion and Seads

Projection Radiography Examples on Corrosion and Erosion

Page 2: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

2

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway3

History: radiographic wall thickness evaluation

BASF drawing from 1954• applied since ca.

1950

• nearly no literatureuntil 1980

• growing importancein chemical industrycaused by on-stream application

• since 1996 projectsBASF und BAM forphysical studies

• Never standardized(first CEN draft2010 by S. Burch, HOIS)

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway4

classical tangential set-up of TRT: film,imagingplate,orflatpanel

pipeline

radiation source, Ir 192

insulationtypical exposure:

profile line

Page 3: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

3

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway5

Projection Radiography

on-site exposure, Ir 192 radiograph

sourcefilm

Example : distribution station

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway6

visual evaluation of wall thickness

error sources:

- wrong density range - inaccurate edge detection (unsharpness)- wrong magnification factor

w

Projection Radiography

Page 4: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

4

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway7

Principle of projection radiography (TRT)

w` measured on film

tangential penetration of pipe wall

pipe

insulation

f - film focus distancer - outer pipe radiusR - outer radius of insulationw‘ - wall thickness projection

on detector plane

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway8

digitized film imaging plate

D7 + Pb,50 µm pixel size

25 % exposure time,145 µm pixel size

AGFA BAM projectin 1995 ff(Peter Willems)

special NDT IP readerprototype(28 µm pixel)

Page 5: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

5

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway9

film digitization (FD) flat panel (DDA)imaging plate (CR)

PC based wall thickness measurement

• single program for evalution of all digital images, no size limitation• support for all detectors by external 16 bit LUT tables for lineari-

sation (gray value proportional to radiation intensity)• easy documentation by protocol generation in PDF format

Projection Radiography

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway10

16 bit software platform

image processing know-how on Windows PC:(since 2006 ISee!, see http://www.kb.bam.de/ic.html)

- fully 16 bit data depth for evaluation and display- unlimited image sizes, limited only by main memory (>1 GByte)- all detectors (digitized film, imaging plates, flat panel detectors)via external 16 bit Lookup Tables (LUT) linearizable, ASCII text

- fast rekursive moving average filtering for arbitrary sizes of high andlow pass filters, convolution with variable kernels, FFT-Filters

- sub-sampling for image display with true averaging- error estimation for measured values and geometric correction- quick documentation of measurements by protocol generation and

transfer to Word (wtScope for BASF, wtModule in Rhythm, GE S&IT)- protection of application by individual encrypted license keys

wtScope

Page 6: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

6

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway11

tangential wall thicknessalgorithm

wall thickness result

table with mea-surement regions

wall thickness deviation in mea-surement region

input exposure parameters

Projection Radiography PC based wall thickness measurement

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway12

synchronous display of positions in profile and image !

position correction by hand, if algorithm fails !

Page 7: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

7

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway13

PC generated measurement protocolProjection Radiography

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway14

PC based wall thickness measurementProjection Radiography

Algorithms : problem: correct detection of wall positionscharacteristic points, curve fitting, CT reconstruction

inner wall of pipe

outer wall of pipemax.

projectedwall thickness w‘

Page 8: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

8

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway15

Limits of Tangential Radiography (TRT):

Energy: Lmax

100 kV : 10 mm200 kV : 30 mm300 kV : 40 mm400 kV : 50 mmSe-75 : 60 mmIr-192 : 75 mmCo-60 : 120 mm

L max

W

Lmax = 2W sqrt(Da/W –1)

200 kV

300 kV

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway16

2003 2004 2005

Algeria Hungary Romania Iran Pakistan Germany Uruguay Syria India Turkey Malaysia Canada

Radiographic Evaluation of Corrosion and Deposits in Pipelines:

Results of an IAEA Co-ordinated Research Programme

Steel pipes up to 20” with NDT film and X-ray, Ir-192, Co-60

Page 9: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

9

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway17

Fabricated Reference Blocks with Steps and Holes:

Iran

Idea:explore inspection methods with known wall thicknesses

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway18

Page 10: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

10

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway19

Ir 192, DN200:

6 11 mm

Co 60, DN300:

14 24 mm

algorithm detects edges, visual not seeable in image :

extension ofapplicationrange in com-parison tovisual evalu-ation

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway20

2006: Validation of wtScope, CR-Tower and Ir-192

BAMBASFGE S&IT

Page 11: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

11

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway21

Validation as measurement method according to ISO 17025:

Steel pipes 50 – 300 mm dia, empty, water filled, w/o insulation

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway22

Second inspection technique possible :

2. Corrosion assessment from local film density changes (Double Wall Technique, DWT)

Radiographic Corrosion Inspection

Page 12: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

12

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway23

erosionw-w

intensity change, I

detector

pipesource

attenuation law: µeff - effective attenuation coefficientIw = I0 e -µeff w

local corrosion : wall thickness differences in penetration direction (DWT)

relative measurement: 2 step algorithm

1. Calibration:

2. Measurement:

µeff = ln ( DREF / DIQI ) / wIQI

w = ln ( DREF / DMEAS ) / µeff

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway24

1. Calculation of effective attenuation coefficient µeff

signal atreference point

signal atmeasurement point

known pipe wall thicknessw at reference point

known hole depth

DWT for localcorrosion

Result: µeff = f(w)dep. on radiation energy andwall thickness differences

Page 13: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

13

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway25

Double wall technique 6" and 8", 100 kV, with and without insulation

y = 0,6689x-0,3385

R2 = 0,7316

y = 0,5039x-0,3927

R2 = 0,3817

0,00

0,05

0,10

0,15

0,20

0,25

0,30

0,35

0,40

0,45

0,50

0 2 4 6 8 10 12 14 16 18

Penetrated steel wall thickness (mm)

Cal

cula

ted

att

enu

atio

n c

oef

fici

ent

(1/m

m)

insulation

decreasing µeff with penetrated wall and insulation

Iran, UruguayIAEA CRP, film

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway26

Double wall technique, Ir 192

0,00

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,10

0 10 20 30 40 50 60

Penetrated steel wall thickness (mm)

Ca

lcu

late

d a

tte

nu

ati

on

co

eff

icie

nt

(1/m

m)

Uruguay Iran

Uruguay with Insulation Iran with Insulation

80 % of all measurements: µeff = 0.046 +/- 0.005 mm-1

IAEA CRP, film Ir-192

Page 14: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

14

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway27

Computer based evaluationwith wtScope/ISee! software:accuracy 10% wt, µeff=0.028/mm

Co-60

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway28

Practical application: profile plot in wall thickness loss

Page 15: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

15

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway29

- 0 mm

+ 10 mm

- 5 mm

real pipe, innercorrosion, insulated

corrosion mappingafter median high pass(gray value prop. penetratedwall thickness, 1x300 points) :

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway30

corroded pipewith weld

+ 5 mm

- 0 mm

- 5 mm

corrosion mappingafter median high pass(gray value prop. topenetrated wall thickness1x200 points) :

Page 16: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

16

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway31

Comparison Film / CR

DWT with Ir-192:

reason: scatter sensitivity!0

0,01

0,02

0,03

0,04

0,05

0,06

0 2 4 6 8 10 12 14

pipe wall thickness [mm]

eff

ec

tiv

e a

tte

nu

ati

on

co

eff

icie

nt

[1/m

m]

CR

Film

Result of wtScope validation for CR Tower byBAM / BASF / GE S&IT

µeff

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway32

Parameter Ir-192 Co-60

DWT: µeff 0.046 +/- 0.005 mm-1 0.028 +/- 0.004 mm-1

TRT: Lmax forDcenter = 2 and Dmax = 4

80 mm 130 mm

TRT: Lmax forDmax = 8

95 mm 155 mm

Determined Lmax limits for TRT and µeff-values for DWT (T3 film systems):

agreed results of IAEA CRP:Limits of film application!

Accuracy for TRT wall measurement: < 0.3 mm

Accuracy for DWT depth measurement: 0.5 mm or 10%wt

Page 17: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

17

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway33

BAM certification of GE S&IT Rhythm WTM versus wtScope:

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway34

SummaryProjection Radiography

inspection technique not yet standardised, written practice necessary !

• program for PC based routine measurements on images from all radiographic detectors, tangential wall thickness measurement and local corrosion, simple documentation

• wall thickness range enlarged compared with visual evaluation in projection radiography

• measurement of corrosion depth (in centre of pipe)• validation as measurement methods acc. to ISO 17025• programs transfered to GE S&IT for worldwide marketing

(Rhythm Version 3 all methods implemented)• differences in sensitivity to scattered radiation between

film and imaging plates

standard development at CEN started in 2010

Page 18: Digital Radiology for Application „on stream“ - SiteGenndt.sitegen.no/customers/ndt/files/7. Corrosion Inspection.pdf · 1 Digital Radiology for Corrosion Inspection Uwe Zscherpel,

18

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway35

See NDT informasjon fra Norsk Forening for Ikke-devstruktiv Proving, April 2011

Digital Radiology for Corrosion Inspection

Uwe Zscherpel, Uwe Ewert, BAM Berlin

Peter Rost, BASF SE, Ludwigshafen; Steve F. Burch, ESR Technology, UK

May 2011, Bodo, Norway36

The End