23
ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER DC Voltage, current Features · Low cost · Bright LED 14.2mm (red) · AC power and DC power available NEW! A1000 Input Specifications DC voltage measurement (Range 12 to 14) Measurement Range Range Input Impedance Accuracy (23°C±5°C, 35 to 85%) Input Protection ±1.999V ±19.99V ±199.9V 1M12 13 14 ±100V ±250V ±500V ± 0.3% of F.S DC current measurement (Range 23 to 25) Measurement Range Range Input Resistance Accuracy (23°C±5°C, 35 to 85%) Input Protection ±19.99mA ±199.9mA ±1.999A 1010.123 24 25 ±150mA ±500mA ±3A ± 0.5% of F.S AC Voltage, current AC voltage measurement (Range 12 to 14 Average) Measurement Range Range Input Impedance Accuracy (23°C±5°C, 35 to 85%) Input Protection 1.999V 19.99V 199.9V 1M12 13 14 50V 50V 500V ± 0.5% of F.S Measurement Range Range Input Resistance Accuracy (23°C±5°C, 35 to 85%) Input Protection 19.999mA 199.9mA 1.999A 5A 1010.1123 24 25 26 150mA 500mA 3A 8A ± 1.0% of F.S Input Frequency: 40 Hz to 100Hz Rectifier Circuit: Reprsents effective value of sine wave by demodulation of mean value Response time: approx 1 sec (10 to 90%) Input Frequency: 40 Hz to 100Hz Rectifier Circuit: Reprsents effective value of sine wave by demodulation of mean value Response time: approx 1 sec (10 to 90%) AC current measurement (Range 23 to 26 Average) Thermocouple (Range KC, JC) Measurement Range Range Sensor Type Accuracy (23°C±5°C, 35 to 85%) Max Resolution 0 to +1000°C 0 to +400°C K J KC JC 1°C 1°C ± 0.8% of F.S Sensor lead Resistance: less than 50Burn out: Flash -1999 Over input voltage: ±5VDC Cold Junction Compensator Accuracy:±2°C RTD (Pt100) (Range PA, PJ) Measurement Range Range Sensor Type Accuracy (23°C±5°C, 35 to 85%) Max Resolution -100.0 to +199.9°C -200 to +600°C Pt100Pt100PA PJ 0.1°C 1°C ± 0.2% of F.S ± 0.4% of F.S Current for resistance: 1mA (TYP) External lead resistance: less than 1 ohm per lead Process (Range 1V, 2A) Measurement Range Range Input Impedance Accuracy (23°C±5°C, 35 to 85%) Input Protection 1 to 5V 4 to 20mA 1M511V 2A ±100V 50mA ± 0.3% of F.S ± 0.4% of F.S Display offset ±1000 fullscale ±100 to 1999 Common Specification Input bias current: 50 pA (TYP) Sampling speed: 2.5/sec Over range indication: When input exceeds the maximum display flash 1999 Max. display: 1999 Display: Red LED 14.2mm height Dimensions: 96mm (H) X 48mm (W) X 75mm (D) DIN size Power supply: 90 to 132 VAC 180 to 264 VAC 5 to 24 VDC Power Consumption: 1.5 VA at AC power 100mA at DC power Operating Temp.: 0 to 50°C, 35 to 85%RH Storage Temp.: -10 to 70°C less than 60% RH Dielectric Strength: Power supply and input, 1500 VAC/1min at AC power Power supply and input, 500 VDC/1min at DC power Insulattion Resistance : 500 VDC 100Mat above terminals

DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

ASAHI KEIKI CO.,LTD.

DIGITAL PANEL METER

DC Voltage, current

Features

· Low cost

· Bright LED 14.2mm (red)

· AC power and DC power availableNEW!

A1000

Input Specifications

• DC voltage measurement (Range 12 to 14)Measurement

RangeRange InputImpedance

Accuracy(23°C±5°C, 35 to 85%)

InputProtection

±1.999V±19.99V±199.9V

1MΩ121314

±100V±250V±500V

± 0.3% of F.S

• DC current measurement (Range 23 to 25)Measurement

RangeRange InputResistance

Accuracy(23°C±5°C, 35 to 85%)

InputProtection

±19.99mA±199.9mA±1.999A

10Ω1Ω

0.1Ω

232425

±150mA±500mA

±3A ± 0.5% of F.S

AC Voltage, current

• AC voltage measurement (Range 12 to 14 Average)

MeasurementRangeRange Input

ImpedanceAccuracy

(23°C±5°C, 35 to 85%)Input

Protection1.999V19.99V199.9V

1MΩ121314

50V50V

500V ± 0.5% of F.S

MeasurementRangeRange Input

ResistanceAccuracy

(23°C±5°C, 35 to 85%)Input

Protection19.999mA199.9mA1.999A

5A

10Ω1Ω

0.1Ω1Ω

23242526

150mA500mA

3A8A

± 1.0% of F.S

Input Frequency: 40 Hz to 100HzRectifier Circuit: Reprsents effective value of sine wave by

demodulation of mean valueResponse time: approx 1 sec (10 to 90%)

Input Frequency: 40 Hz to 100HzRectifier Circuit: Reprsents effective value of sine wave by

demodulation of mean valueResponse time: approx 1 sec (10 to 90%)

• AC current measurement (Range 23 to 26 Average)

Thermocouple (Range KC, JC)Measurement

RangeRange SensorType

Accuracy(23°C±5°C, 35 to 85%)

MaxResolution

0 to +1000°C0 to +400°C

KJ

KCJC

1°C1°C ± 0.8% of F.S

Sensor lead Resistance: less than 50ΩBurn out: Flash -1999Over input voltage: ±5VDCCold Junction Compensator Accuracy:±2°C

RTD (Pt100Ω) (Range PA, PJ)Measurement

RangeRange SensorType

Accuracy(23°C±5°C, 35 to 85%)

MaxResolution

-100.0 to +199.9°C-200 to +600°C

Pt100ΩPt100Ω

PAPJ

0.1°C1°C

± 0.2% of F.S± 0.4% of F.S

Current for resistance: 1mA (TYP)External lead resistance: less than 1 ohm per lead

Process (Range 1V, 2A)Measurement

RangeRange InputImpedance

Accuracy(23°C±5°C, 35 to 85%)

InputProtection

1 to 5V4 to 20mA

1MΩ51Ω

1V2A

±100V50mA

± 0.3% of F.S± 0.4% of F.S

Display

offset ±1000fullscale ±100 to 1999

Common SpecificationInput bias current: 50 pA (TYP)Sampling speed: 2.5/secOver range indication: When input exceeds the maximum display

flash 1999Max. display: 1999Display: Red LED 14.2mm heightDimensions: 96mm (H) X 48mm (W) X 75mm (D) DIN sizePower supply: 90 to 132 VAC

180 to 264 VAC5 to 24 VDC

Power Consumption: 1.5 VA at AC power100mA at DC power

Operating Temp.: 0 to 50°C, 35 to 85%RHStorage Temp.: -10 to 70°C less than 60% RHDielectric Strength: Power supply and input, 1500 VAC/1min at

AC powerPower supply and input, 500 VDC/1min at DCpower

Insulattion Resistance : 500 VDC 100MΩ at above terminals

Page 2: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

ASAHI KEIKI CO.,LTD.

DIGITAL PANEL METERA1000

Model Code

A11 -

Range

Power Supply 1. 90 to 132 VAC2. 180 to 264 VAC3. 5 to 24 VDC ±10%

Input: 1. DC voltage 2. DC current 4. AC voltage 5. AC current 6. AC current 5A B. Process C. Thermocouple D. RTD

Dimensions

Front View

Side View

96

48

538.9

7.8

8.7

Connection Diagram

12 r

ange

HI

13-1

4 ra

nge

HI

NC

LO

HO

LD

CO

M

PO

W (-

)

PO

W (+

)

23 r

ange

HI

24 r

ange

HI

25 r

ange

HI

LO

HO

LD

CO

M

PO

W (-

)

PO

W (+

)

+ - S

NC

HO

LD

CO

M

PO

W (-

)

PO

W (+

) A B C

NC

HO

LD

CO

M

PO

W (-

)

PO

W (+

)

1V r

ange

HI

2A r

ange

HI

NC

LO

HO

LD

CO

M

PO

W (-

)

PO

W (+

)

DC voltage (12 to 14 range)AC voltage (12 to 14 range)

DC current (23 to 25 range)AC current (23 to 25 range)

Thermocouple (KC, JC) RTD (PA, PJ)

Process

Page 3: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

ASAHI KEIKI CO.,LTD.

DIGITAL PANEL METER

DC Voltage Measurement

DC Current Measurement

MeasurementRangeRange Input Impedance AccuracyInput Protection

±199.9mV±1.999V±19.99V±199.9V

100MΩ

1MΩ

11121314

±50V

±250V ± (0.1% of F.S)

MeasurementRangeRange Input Impedance AccuracyInput Protection

±1.999mA±19.99mA±199.9mA±1.999A

100Ω10Ω1Ω

0.1Ω

22232425

±50mA±150mA±500mA

±3A

± (0.2% of F.S)

Power supply Non-isolation typeVoltage: 5VDC±5%Consumption: 60mA

Isolation typeVoltage: 5 to 24VDCConsumption: 100mA

SpecificationInput configuration: Single EndedConversion rate: 2.5/secMax display: 1999Overrange indication : When input exceeds the maximum display,

0000 or -0000 flashesDisplay : Red LED, 10mmPolarity : A "-" is displayed automaticallyDecimal point : Settable to any digit position by front SWExternal control : HoldOperating Temp. : 0 to 50˚C 35 to 85% RHDimensions : 48mm(W)24mm(H)39.7mm(D) DIN sizeWeight : 40gDielectric strength : Power supply and input terminal at 500VDC/

1minCase and each terminals at 1500VAC/1min

Insulation resistance : 500VDC 100M at the above terminals

* Replacement for AP-200, AP-201A, AP-202A(no option)

Features

· LED hight 10mm

· Power supply 5VDC or 5 to 24VDC

· 3 1/2 digitNEW!

A2100

Ordering Code

A21 0 -

Range

Power Supply 1. non-isolation type (5VDC)2. isolation type (5 to 24VDC)

11. ±199.9mV12. ±1.999V13. ±19.99V14. ±199.9V22. ±1.999mA23. ±19.99mA24. ±199.9mA25. ±1.999A

Dimensions

22.2

24

Min65

48 40

4.5

Min35

45

Panel Cutout

Page 4: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

ASAHI KEIKI CO.,LTD.

DIGITAL PANEL METER

DC Voltage MeasurementMeasurement

RangeRange Input Impedance AccuracyInput Protection

±1.999V±19.99V±199.9V

100MΩ

1MΩ

121314

±50V

±250V ± (0.1% of F.S)

Features

· LED hight 10mm

· Power supply 5 to 24VDC (Isolation)

· 4 1/2 digitNEW!

A2200

Ordering Code

A222 0 -

Range12. ±1.9999V13. ±19.999V14. ±199.99V

Dimensions

22.2

24

Min65

48 40

4.5

Min35

45

Panel Cutout

Power supply Isolation typeVoltage: 5 to 24VDCConsumption: 100mA

SpecificationInput configuration: Single EndedConversion rate: 2.5/secMax display: 19999Overrange indication : When input exceeds the maximum display,

0000 or -0000 flashesDisplay : Red LED, 10mmPolarity : A "-" is displayed automaticallyDecimal point : Settable to any digit position by front SWExternal control : HoldOperating Temp. : 0 to 50˚C 35 to 85% RHDimensions : 48mm(W)24mm(H)39.7mm(D) DIN sizeWeight : 40gDielectric strength : Power supply and input terminal at 500VDC/

1minCase and each terminals at 1500VAC/1min

Insulation resistance : 500VDC 100M at the above terminals

* Replacement for AP-241A, AP-242A, AP-244A(no option)

Page 5: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1
Page 6: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Input Specification (A5XXX-)• DC voltage, current

Range

11

Displayoffset ±9999full scale 0 to ±9999

Maximum Resolution

10 µV

Input Impedance

100 MΩ

Input Protection

±100 V

Input configuration : Single endedMeasuring method : ∆∑typeNormal mode rejection : More than NMR 50dB (50/60 Hz)

• AC voltage, current (Average)

• AC voltage, current (TRUE-RMS)

Range

111213

Measurementrange99.99 mV999.9 mV9.999 V

Input Frequency

40 Hz to 1 kHz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution10 µV100 µV1 mV

InputImpedance

more than 1 MΩ

InputProtection100 V100 V250 V

Accuracy

±(0.2% of rdg + 20 digit)±(0.2% of rdg + 20 digit)±(0.2% of rdg + 20 digit)

Input configuration : Single endedResponse time : Approx. 1 sec.Crest factor : 4:1 at fullscale (only for TRUE-RMS)Dead zone : 0 to 99 digit

• Resistance

Range

11121314

Measurementrange99.99 Ω999.9 Ω9.999 kΩ99.99 kΩ

Display

offset ±9999full scale 0 to ±9999

Accuracy

±(0.1% of FS)

Range12131415

Measurement range±999.9 mV±9.999 V±99.99 V±600 V

Display

offset ±9999full scale 0 to ±9999

Maximum Resolution10 µV1 mV10 mV100 mV

Input Impedance100 MΩ1 MΩ10 MΩ10 MΩ

Input Protection±100 V±250 V±250 V±600 V

Accuracy±(0.1% of FS)±(0.1% of FS)±(0.1% of FS)±(0.15% of FS)

Range232425

Measurement range±9.999 mA±99.99 mA±999.9 mA

Display

offset ±9999full scale 0 to ±9999

Maximum Resolution1 µA10 µA100 µA

Input Impedance10 Ω1 Ω0.1 Ω

Input Protection±100 mA±500 mA±3 A

Accuracy

±(0.2% of FS)±(0.2% of FS)±(0.3% of FS)

Range

111213

Measurementrange99.99 mV999.9 mV9.999 V

Input Frequency

40 Hz to 1 kHz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution10 µV100 µV1 mV

InputImpedance

more than 1 MΩ

InputProtection100 V100 V250 V

Accuracy

±(0.2% of rdg + 10 digit)±(0.2% of rdg + 10 digit)±(0.2% of rdg + 10 digit)

Range

1415

Measurementrange99.99 V600 V

Input Frequency

40 Hz to 1 kHz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution10 mV100 mV

InputImpedance

more than 1 MΩ

Accuracy

±(0.2% of rdg + 10 digit)±(0.3% of rdg + 10 digit)

InputProtection250 V600 V

Range

232425

Measurementrange9.999 mA99.99 mA999.9 mA

Input Frequency

40 Hz to 1 kHz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution1 µA10 µA100 µA

InputImpedance10 Ω1 Ω0.1 Ω

InputProtection100 mA500 mA3 A

Accuracy

±(0.5% of rdg + 10 digit)±(0.5% of rdg + 10 digit)±(0.5% of rdg + 10 digit)

Range

26

Measurementrange

5 A

Input Frequency

50 Hz or 60 Hz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution

1 mA

InputImpedance

CT

InputProtection

8 A

Accuracy

±(0.5% of rdg + 10 digit)

Range

1415

Measurementrange99.99 V600 V

Input Frequency

40 Hz to 1 kHz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution10 mV100 mV

InputImpedance

more than 1 MΩ

InputProtection250 V600 V

Accuracy

±(0.2% of rdg + 20 digit)±(0.3% of rdg + 20 digit)

Range

232425

Measurementrange9.999 mA99.99 mA999.9 mA

Input Frequency

40 Hz to 1 kHz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution1 µA10 µA100 µA

InputImpedance10 Ω1 Ω0.1 Ω

InputProtection100 mA500 mA3 A

Accuracy

±(0.5% of rdg + 20 digit)±(0.5% of rdg + 20 digit)±(0.5% of rdg + 20 digit)

Range

26

Input Frequency

50 Hz or 60 Hz

Display

offset ±9999full scale 0 to ±9999

MaximumResolution

1 mA

InputImpedance

CT

InputProtection

8 A

Accuracy

±(0.5% of rdg + 20 digit)

Measurementrange

5 A

available Fahrenheit displayCold junction compensator accuracy : ±1°C (10 to 40°C)Sensor lead resistance : less than 50ΩLinearizing method : Digital linearizingBurn out alarm : -----

Range

KAKBJTSRB

SensortypeKKJTSRB

Measurementrange–50.0 to 199.9°C–50 to 1200°C–50 to 1000°C–50 to 400°C0 to 1700°C–10 to 1700°C100 to 1800°C

MaximumResolution0.1°C1°C1°C1°C1°C1°C1°C

Accuracy

±(0.5% of FS)±(0.2% of FS)±(0.2% of FS)±(0.6% of FS)±(0.4% of FS)±(0.4% of FS)±(0.4% of FS) over 500°C

• Thermocouple

Current

5 mA0.5 mA50 µA5 µA

Accuracy

±(0.2% of FS)±(0.1% of FS)±(0.1% of FS)±(0.1% of FS)

Maximum Resolution

10 mΩ100 mΩ1 Ω10 Ω

Measurement range

±99.99 mV

02

03

04

05

08

09

06

07

10

11

12

13

01

Page 7: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Output Specification

• RS-485 (Conforming to EIA RS-485) (A5XX4-XX)

Communication method : Full duplexTransmission speed : 2400/4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/8 bitParity : Even parity/odd parityError detection : BCCStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmission control process : Ignored processSignal name : + non reversal output

– reversal outputMaximum No. of meter connected : 31Line length : Up to 500 m in total

• RS-232C (Conforming to EIA RS-232C) (A5XX3-XX)

Communication method : Full duplexTransmission speed : 2400/4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/8 bitParity : Even parity/odd parityStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmission control process : Ignored process

Output0 to 1 V0 to 10 V1 to 5 V4 to 20 mA

Resistive loadmore than 10 kΩmore than 10 kΩmore than 10 kΩless than 550 Ω

Output method : PWM methodScaling : Digital scaling

Accuracy

±(0.5% of FS)

• Analog output (A5XX2-XX)

• HI & LO setpoint output (A5XX1-XX)

Setting range : –9999 to 9999Hysteresis : 1 to 999 digit for each setpointsRelay contact capacity : AC240V 8A resistive load DC30V 8A resistive load

Indication > High setpointHigh setpoint Indication Lo setpointIndication < Lo setpoint

HIGOLO

• RTD

available Fahrenheit displayCurrent for resistance : Approx. 1 mAExternal lead resistance : Less than 10 Ω/leadLinearizing method : Digital linearizingBurn out alarm : -----

14

• FrequencyRange

11121314

Measurement range0.1 to 200 Hz1 to 2000 Hz0.01 to 20 kHz0.1 to 200 kHz

Display

Prescale: 0.001 to 5 1 to 100

Maximum Resolution0.1 Hz1 Hz10 Hz100 Hz

Display Renewal time1 to 10 s1 s100 ms100 ms

Accuracy±(0.2% of FS)±(0.2% of FS)±(0.2% of FS)±(0.2% of FS)

Input typeOpen collectorLogicMagnet

Input voltage levelL: less than 1 V (5 V, 2.2 kΩ) pullupL: less than 1 V, HI: 2.5 to 15 V0.3 to 30 V P-P

Input typeVoltage

Input voltage level

50 to 500 V rms

Input Protection

500 V

Input Protection30 V15 V15 V

15

16

• Strain gaugePower supplyfor sensor

5 V10 V

Zero adjustment range

–0.3 to +2 mV/V

Span adjustment range

1 to 3 mV/V

Maximum Resolution

0.5 µV/digit1 µV/digit

Accuracy

±(0.1% of FS) +2 digit

Sensor : 350 ΩPower supply for sensor : 5 V±5% (less than 15 mA) 10 V±5% (less than 30 mA)

17

• Process with sensor power supplyRange

1 V2 A

Measurement range

1 to 5 V4 to 20 mA

Display

offset ±9999full scale 0 to ±9999

Input Impedance

1 MΩ10 Ω

Input protection

±100 V±100 mA

Accuracy±(0.2% of FS)±(0.2% of FS)

19

Power supply for sensor : 12 V DC ±10% 50 mA 24 V DC ±10% 25 mA

• ProcessRange

1 V2 A

Measurement range

1 to 5 V4 to 20 mA

Display

offset ±9999full scale 0 to ±9999

Input Impedance

1 MΩ10 Ω

Input protection

±100 V±100 mA

Accuracy±(0.2% of FS)±(0.2% of FS)

18

Sensor typePT100ΩPT100Ω

Measurement range–100.0 to 199.9°C–100 to 600°C

Maximum Resolution0.1°C1°C

Accuracy±(0.15% of FS)±(0.3% of FS)

RangePAPB

Page 8: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

We reserve the right to change specifications without notice.

33-6, YAGUCHI 2-CHOME, OHTA-KU,TOKYO 146-8505, JAPANFAX : (03)3757-2989PHONE: (03)3579-3893http:// www.asahikeiki.co.jpE-mail: [email protected]

Printed in Japan, Aug. 2004 (KP)

45+

0.6

-0

92 +0.8- 0

MIN

.70

MIN.120

92

96

487

121

45

147.

5

Common SpecificationDisplay : Main display Red LED 14.2 mm height

Sub display Green LED 8 mm heightConversion rate : 12.5 times/sec.Maximum display : 9999Overrange indication : When input exceeds the maximum display,

display OL or –OLZero display : Leading zero suppressionDecimal point : Settable to any digit positionExternal control : Start/Hold, Peak Hold, Digital ZeroOperating temp. : 0 to 50°C 35 to 85% RHStorage temp. : –10 to 70°C less than 60% RHPower supply : AC 100 to 240V±10%(AC main unit)

DC 9 to 60 V (DC main unit)Power consumption : approx 4 VA (at 100 V)Dimensions : 96 mm (W) X 48 mm (H) X 147.5 mm (D) DIN sizeWeight : approx. 450 gDielectric strength (AC) : Power supply/input terminal/output terminal AC2000 V/1 min.

Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.

Dielectric strength (DC) : Power supply/input terminal/output terminal DC500 V/1 min.Input terminal/output terminal DC500 V/1 min.Case/power supply/input terminal output terminal AC2000 V/1 min.

Insulation resistance : DC500 V more than 100 MΩ at the above terminals

Dimensions Ordering CodeA 5

Input

Output

Display board

Main board

01. DC voltage (±99.99 mV)02. DC voltage (±999.9 mV to ±600V)03. DC current (±9.999 mA to ±999.9 mA)04. AC voltage AVG (99.99 mV to 9.999 V)05. AC voltage AVG (99.99 V to 600 V)06. AC voltage RMS (99.99 mV to 9.999 V)07. AC voltage RMS (99.99 V to 600 V)08. AC current AVG (9.999 mA to 999.9 mA)09. AC current AVG (5 A)10. AC current RMS (9.999 mA to 999.9 mA)11. AC current RMS (5 A)12. Resistance (99.99 Ω to 99.99 kΩ)13. Temperature (Thermocouple)14. Temperature (RTD)15. Frequency (Open collector, Logic, Magnet)16. Frequency (50 to 500 Vrms)17. Strain gauge18. 1 to 5 V, 4 to 20 mA19. 1 to 5 V, 4 to 20 mA with sensor power supply

∗ Impossible to use only No.19 input for DC power supply

0. None1. HI & LO setpoint2. Analog output3. RS-232C4. RS-4855. HI & LO setpoint + analog output6. HI & LO setpoint + analog output + RS-232C7. HI & LO setpoint + analog output + RS-485

1. Single2. Multiple

1. AC100 - 240 V (±10%)2. DC9 - 60 V

Page 9: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Display single type (A6X2X-XX)Display single type (A6X2X-XX)

Display multi type (A6X1X-XX)Display multi type (A6X1X-XX)

Page 10: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Input Specifications DC voltage,current• A6XX1-XX

Minimum display 50 digits

Range Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)1112131415

±99.99 mV±999.9 mV±9.999 V±99.99 V±700 V

±50 V±50 V±250 V±250 V±700 V

offset ±9999full scale ±9999

±(0.03% of rdg + 1digit)

±(0.1% of rdg + 2digit)

• A6XX2-XXRange Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)

21222324

±99.99 uA±999.9 uA±9.999 mA±99.99 mA

±10 mA±10 mA±50 mA±500 mA

±(0.1% of rdg + 2 digit)offset ±9999full scale ±9999

• A6XX5-XXRange Measurement Range Display Input Protection Accuracy (23˚C ±5˚C, 35 ~ 85% RH)

21222324

99.99 uA999.9 uA9.999 mA99.99 mA

10 mA10 mA50 mA500 mA

±(0.5% of rdg + 20 digit)offset ±9999full scale ±9999

AC voltage, current (TRUE-RMS)• A6XX4-XX

Range Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)1112131415

99.99 mV999.9 mV9.999 V99.99 V700.0 V

50 V50 V250 V250 V700 V

offset ±9999 full scale ±9999

±(0.2% of rdg + 20 digit)

±(0.3% of rdg + 20 digit)

• A6XX3-XXRange Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)

2526

±999.9 mA±2.000 A

±3 Aoffset ± 9999full scale ±9999

±(0.1% of rdg + 2 digit)

• A6XX6-XXRange Measurement Range Display Input Protection Accuracy (23˚C ±5˚C, 35 ~ 85% RH)

2526

999.9 mA5 A

3 A8 A

offset ±9999full scale ±9999

±(0.7% of rdg + 20 digit)

Minimum display 50 digits

Measurement method: Two or Four wire (internal socket changable)

Resistance• A6XX7-XX

Range Measurement Range Display Current Accuracy (23°C ±5˚C, 35 ~ 85% RH)11121314

99.99 Ω999.9 Ω9.999 KΩ99.99 kΩ

5 mA0.5 mA50 uA5 uA

offset ±9999full scale ±9999

±(0.1% of rdg + 4digit)

Frequency• A6XX9-XX

Range Measurement Range Accuracy (23˚C ±5, 35 ~ 85% RH)111213

0.1 to 999.9 Hz1 to 9.999 kHz10 to 99.99 kHz

±(0.2% of FS)

Thermocouple • RTD• A6XX8-XX

Range Sensor type Measurement Range Maximum Resolution Accuracy (23˚C ±5˚C, 35 ~ 85% RH)KAKBJTSRB

PAPB

KKJTSRBPT100 ΩPT100 Ω

0.1˚C1˚C1˚C1˚C1˚C1˚C1˚C0.1˚C1˚C

-50.0 to 199.9˚C-50 to 1200˚C-50 to 1000˚C-50 to 400˚C0 to 1700˚C-10 to 1700˚C100 to 1800˚C-100.0 to 199.9˚C-100 to 600˚C

±(0.5% of FS)±(0.2% of FS)±(0.2% of FS)±(0.6% of FS)±(0.4% of FS)±(0.4% of FS)±(0.4% of FS)±(0.15% of FS)±(0.3% of FS)

Minimum display 50 digits

available Fahrenheit displayCold junction compensator accuracy : ±2˚C (10 to 40˚C)Sensor lead resistance : less than 50 ΩLinearzing method : Digital linearizingBurn out alarm : - - - - -Conversion time : 2.5/sec

• A6XX9-XXInput type Input voltage level Input ProtectionOpen collectorLogicMagnetVoltage

L: less than 1.5 V (5V, pullup)L: less than 1 V, HI: 2.5 to 15 V0.3 to 30 V P-P30 V rms to 500 V rms

30 V 15 V 30 V 500 V

Prescale : 0.01 ~ 10.00PPR : 1~100Power supply for sensor : 12 VDC ±10%

Page 11: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Strain gauge• A6XXA-XX

sensor Zero adjustment range Span adjustment range Measurement range Accuracy 5 V10 V

-1 to + 1 mV/V -4 ~ + 4 mV/V1 to 3mV/V ±(0.1% of FS) + 2 digit

Sesnor : 350 ΩPower supply for sensor : 5 V ± 5% (less than 15 mA)

10 V ± 5% (less than 30 mA)Conversion speed : 1000/sec

Process• A6XXB-XX

sensor Measurement Range Display Accuracy 1 V2 V2 A3 A

1 to 5 V±5 V4 to 20 mA±20 mA

offset: ±9999full scale 0 to ±9999

±(0.03% of rdg + 2digit)±(0.1% of rdg + 3digit)

Excitation power supply : 12 VDC ±5%24 VDC ±5% 25 mA

Output Specification

Start/Hold : Shorted between COM terminal and start/hold terminal or same level / holdOpen COM terminal and start/hold terminal or 5 V / start

D. ZERO : Shorted between COM terminal and D.ZERO terminal / ONP.HOLD : Shorted between COM terminal and P. HOLD terminal / ONR.RE (relay reset) : Shorted between COM terminal and R.RE terminal / ON P.SEL1 to 3 : as below

pattern 1OFFOFFOFF

P.SEL1 P.SEL2 P.SEL3

pattern 2ONOFFOFF

pattern 3OFFONOFF

pattern 4ONONOFF

pattern 5OFFOFFON

pattern 6ONOFFON

pattern 7OFFONON

pattern 8ONONON

ON : Shorted between COM terminal and P.SEL terminal or same levelOFF: Open between COM terminal and P.SEL terminal or 5 V

• HI & LO setpoints output (A6XXX-1X Relay output) (A6XXX-2X Photocoupler)

Comparative condition:Indication > High setpointHIgh setpoint Indication Lo setpointIndication < Lo setpoint

HIGOLO

Option• External control (A6XXX-X1)

Communication method :Full duplexTransmission speed :4800/9600/19200/38400 bpsStart bit :1 bitData length :7 bit/8 bitParity :Even parity/ odd parity/ noneStop bit :1 bit/2 bitCharacter code :ASCII codeTransmission control process :Ignord process

• RS232C (Conforming to EIA RS-232C)(A6XXX-X5)

Communication method : Full duplexTransmission speed : 4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/ 8 bitParity : Even parity/ odd marity/ noneError detection : BCCStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmssion control process : Ignord processSignal name : +non reversal output

-reversal outputMaximum no of meter connected : 31Line length : up to 500m in total

• RS-485 (conforming to EIA RS-485)(A6XXX-X6)

Type of output : Open collector or TTLLogic : ChangeableOutput rate : DC30 V 10 mA (open collector)

Funout 2 (TTL)

• BCD output (A6XXX-X2 TTL)(A6XXX-X3 Open collector)

Setting range : -9999 to 9999Hysteresis : 1 to 999 digit for each setpointsRelay contact capacity : AC250 V 2 A resistive load

DC30 V 2 A resistive loadPhotocoupler capacity : DC30 V 20 mA

• Analog output (A6XXX-X4)output Load resistance Accuracy Ripple

0 to 1 V 0 to 10 V 1 to 5 V

4 to 20 mA

more than 10 kΩ

less than 550 Ω

±(0.5% of F.S)50 mV p-p

25 mV p-p

Output method : PWM methodScaling : Digital scalingResolution : 13 bitReponse time : approx 0.5 sec

Page 12: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Common SpecificationDisplay : Main display Red or Green LED 20 mm

Sub display Red LED 6 mmConversion rate : 1000 times/sec.Maximum display : 9999Overrange indication : When input exceed the maximum display

display OVER or –OVERZero display : Leading zero suppressionDecimal point : Settable to any digit positionOperating temp. : 0 to 50°C 35 to 85% RHStorage temp. : –10 to 70°C less than 60% RHPower supply : AC 100 to 240 V ±10%

DC 12 to 48 V ±10%Power consumption : 8 VA (max. load)Dimensions : 96 mm (W) X 48 mm (H) X 97.5 mm (D) DIN sizeWeight : approx. 450 gDielectric strength (AC) : Power supply/input terminal/output terminal AC1500 V/min.

(DC) : Power supply/input terminal/output terminal DC500 V/min. (Common) : Case/each terminal AC1500 V/min.

Insulation resistance : DC500 V more than 100 MΩ at the above terminals

A 6

Option 0. none1. External control2. BCD output (TTL)3. BCD output (open collector)4. Analog output5. RS-232C6. RS-4857. RS-232C, analog output8. RS-485, analog output

Comparator output 0. none1. Relay2. Photocoupler

Input 1. DC voltage2. DC current3. DC current4. AC voltage5. AC current6. AC current7. Resistance8. Temperature (T/C, RTD)9. FrequencyA. Strain gaugeB. Process

Displayb board 1. Multiple2. Single

Power supply 1. AC 100 to 240 V2. DC12 to 48 V

We reserve the right to change specifications without notice.

33-6, YAGUCHI 2-CHOME, OHTA-KU,TOKYO 146-8505, JAPANFAX : (03)3757-2989PHONE: (03)3579-3893http:// www.asahikeiki.co.jpE-mail: [email protected]

Printed in Japan, Dec. 2003 (YG)

Muliple

Input Option

Comparator Power

Single

48

(97.

5)

10.9

77

0.5

(86.

5)

(21.

5)

44.8

91.5

102.5

45+

0.6

-0

92 +0.8- 0

MIN

.70

MIN.120

Dimensions Ordering Code

Page 13: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1
Page 14: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Input Specifications DC voltage,current• A7X11-X

Minimum display 50 digitsFrequency range: 40Hz to 1kHzResponse time: Approx 1 sec(10% to 90%)Conversion rate: 1000times/sec

Range Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)1112131415

±99.99 mV±999.9 mV±9.999 V±99.99 V±700 V

±50 V±50 V±250 V±250 V±700 V

offset ±9999full scale ±9999

±(0.03% of rdg + 1digit)

±(0.1% of rdg + 2digit)

• A7X12-XRange Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)

21222324

±99.99 uA±999.9 uA±9.999 mA±99.99 mA

±10 mA±50 mA±50 mA±700 mA

±(0.1% of rdg + 2 digit)offset ±9999full scale ±9999

• A7X15-XRange Measurement Range Display Input Protection Accuracy (23˚C ±5˚C, 35 ~ 85% RH)

21222324

99.99 uA999.9 uA9.999 mA99.99 mA

10 mA10 mA50 mA500 mA

±(0.5% of rdg + 20 digit)offset ±9999full scale ±9999

AC voltage, current (TRUE-RMS)• A7X14-X

Range Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)1112131415

99.99 mV999.9 mV9.999 V99.99 V700.0 V

50 V50 V250 V250 V700 V

offset ±9999 full scale ±9999

±(0.2% of rdg + 20 digit)

±(0.3% of rdg + 20 digit)

• A7X13-XRange Measurement Range Display Input Protection Accuracy (23˚C ± 5˚C, 35 ~ 85% RH)

2526

±999.9 mA±2.000 A

±3 Aoffset ± 9999full scale ±9999

±(0.1% of rdg + 2 digit)

• A7X16-XRange Measurement Range Display Input Protection Accuracy (23˚C ±5˚C, 35 ~ 85% RH)

2526

999.9 mA5 A

3 A8 A

offset ±9999full scale ±9999

±(0.7% of rdg + 20 digit)

Minimum display 50 digitsFrequency range: 40Hz to 1kHzResponse time: Approx 1 sec(10% to 90%)Conversion rate: 1000times/sec

Conversion rate: 1000times/sec

Conversion rate: 1000times/sec

Conversion rate: 1000times/sec

Conversion rate: 100times/secMeasurement method: Two or Four wire (internal socket changable)

Resistance• A7X17-X

Range Measurement Range Display Current Accuracy (23°C ±5˚C, 35 ~ 85% RH)11121314

99.99 Ω999.9 Ω9.999 KΩ99.99 kΩ

5 mA0.5 mA50 uA5 uA

offset ±9999full scale ±9999

±(0.1% of rdg + 4digit)

Thermocouple • RTD• A7X18-X

Range Sensor type Measurement Range Maximum Resolution Accuracy (23˚C ±5˚C, 35 ~ 85% RH)KAKBJTSRB

PAPB

KKJTSRBPT100 ΩPT100 Ω

0.1˚C1˚C1˚C1˚C1˚C1˚C1˚C0.1˚C1˚C

-50.0 to 199.9˚C-50 to 1200˚C-50 to 1000˚C-50 to 400˚C0 to 1700˚C-10 to 1700˚C100 to 1800˚C-100.0 to 199.9˚C-100 to 600˚C

±(0.5% of FS)±(0.2% of FS)±(0.2% of FS)±(0.6% of FS)±(0.4% of FS)±(0.4% of FS)±(0.4% of FS)±(0.15% of FS)±(0.3% of FS)

Minimum display 50 digitsFrequency range: 40Hz to 1kHzResponse time: Approx 1 sec(10% to 90%)Conversion rate: 1000times/sec

available Fahrenheit displayCold junction compensator accuracy : ±2˚C (10 to 40˚C)Sensor lead resistance : less than 50 ΩLinearzing method : Digital linearizingBurn out alarm : - - - - -Conversion time : 2.5times/sec

Page 15: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Strain gauge• A7X1A-X

sensor Zero adjustment range Span adjustment range Measurement range Accuracy 5 V10 V

-1 to + 1 mV/V -4 ~ + 4 mV/V1 to 3mV/V ±(0.1% of FS) + 2 digit

Frequency• A7X19-X

Range Measurement Range Accuracy (23˚C ±5, 35 ~ 85% RH)111213

0.1 to 999.9 Hz1 to 9.999 kHz10 to 99.99 kHz

±(0.2% of FS)

Input type Input voltage level Input ProtectionOpen collector Logic Magnet Voltage

L: less than 1.5 V (5V, pullup)L: less than 1 V, HI: 2.5 to 15 V0.3 to 30 V P-P30 V rms to 500 V rms

30 V 15 V 30 V 500 V

Prescale : 0.01 ~ 10.00PPR : 1~100Power supply for sensor : 12 VDC ±10%

Sesnor : 350 ΩPower supply for sensor : 5 V ± 5% (less than 15 mA)

10 V ± 5% (less than 30 mA)Conversion speed : 1000/sec

Process• A7X1B-X

sensor Measurement Range Display Accuracy 1 V2 V2 A3 A

1 to 5 V±5 V4 to 20 mA±20 mA

offset: ±9999full scale 0 to ±9999

±(0.03% of rdg + 2digit)±(0.1% of rdg + 3digit)

Conversion rate : 1000times/secExcitation power supply : 12 VDC ±5%

24 VDC ±5% 25 mA

Output Specification• HH, HI & LO, LLsetpoints outputComparative condition:

Indication > High High setpointHigh High setpoint Indication > High setpointHigh setpoint Indication Lo setpointLow setpoint > Indication Low Low setpointLow Low setpoint > Indication

HHHI

GOLOLL

Communication method :Full duplexTransmission speed :4800/9600/19200/38400 bpsStart bit :1 bitData length :7 bit/8 bitParity :Even parity/ odd parityStop bit :1 bit/2 bitCharacter code :ASCII codeTransmission control process :Ignord process

• RS232C (Conforming to EIA RS-232C)

Communication method : Full duplexTransmission speed : 4800/9600/19200/38400 bpsStart bit : 1 bitData length : 7 bit/ 8 bitParity : Even parity/ odd marityError detection : BCCStop bit : 1 bit/2 bitCharacter code : ASCII codeTransmssion control process : Ignord processSignal name : +non reversal output

-reversal outputMaximum no of meter connected : 31Line length : up to 500m in total

• RS-485 (conforming to EIA RS-485)

Type of output : Open collector or TTLLogic : ChangeableOutput rate : DC30 V 10 mA (open collector)

Funout 2 (TTL)

• BCD output

Setting range : -9999 to 9999Hysteresis : 1 to 999 digit for each setpointsRelay contact capacity : AC125 V 0.3 A resistive load

DC30 V 1 A resistive loadPhotocoupler capacity : DC30 V 50 mA

• Analog output (PWM)output Load resistance Accuracy Ripple

0 to 1 V 0 to 10 V 1 to 5 V

4 to 20 mA

more than 10 kΩ

less than 550 Ω

±(0.5% of F.S)±50 mV p-p

±25 mV p-p

Output method : PWM methodScaling : Digital scalingResolution : 13 bitReponse time : approx 0.5 sec

Page 16: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Common SpecificationMaximum display : 9999Overrange indication : When input exceed the maximum display

display OVER or -OVERZero display : Leading zero suppressionDecimal point : Settable to any digit positionOperating temp : 0 to 50°C (35 to 85% RH)Storage temp. : -10 to 70°C less than 60%RHPower supply : 100 to 240VAC ± 10%

12 to 48VDCPower consumption : 8VA (At AC) 7W(At DC)Dimensions : 72mm (W) × 36mm (H) × 118mm (D)Weight:approx : 160gDielectric strength (AC) : Power supply/input terminal/output terminal AC1500 V/min

(DC) : Power supply/input terminal/output terminal DC500 V/min: Input terminal/output terminal DC500V/min

Insulation resistance : DC500V more than 100MΩ at the above terminals

We reserve the right to change specifications without notice.

3rd floor, Ehara bldg., 5-7, Kaji-cho 1-chome, Chiyoda-ku,TOKYO 101-0044, JAPANFAX : (03)3251-5576PHONE: (03)3251-5567http:// www.asahikeiki.co.jpE-mail: [email protected]

Printed in Japan, Feb. 2006 (KS)

Dimensions Ordering CodeA 7 1 –

Output

Input

0. none1. Relay output2. Photocoupler output3. BCD output (TTL)4. BCD output (Open collector)5. BCD output (TTL), Photocoupler output6. BCD output (Open collector), Photocoupler

output7. Analog output8. Analog output, Photocoupler output9. RS-232CA. RS-485B. RS-232C, Photocoupler outputC. RS-485, Photocoupler output

1. DC voltage2. DC current3. DC current4. AC Voltage5. AC current6. AC current7. Resistance8. Temperature (T/C, RTD)9. FrequencyA. Strain gaugeB. Process

Power supply 1. AC100 to 240V2. DC12 to 48V

68

80

87

72

36

7

118

33

HHHIGOLOLL

REPHDZMEP1P2P3

ME

Min.96

68+0.7-0

33-0 +0

.6

Page 17: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Input Specifications

DC voltage , current

A83 1-0 (DC voltage)

A83 2-0 (DC current)

AC voltage, current (TRUE-RMS)

A83 4-0 (AC voltage)

A83 5-0 (AC current)

Process

A83 B-0

ASAHI KEIKI CO.,LTD.

UNIVERSAL TYPE DIGITAL PANEL METERA8000

Featuers

· Power Supply : 5V to 12VDC, 12V to 24VDC

· BCD Output (option)

· 4 1/2 digit

NEW!

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.1% of rdg + 2 digit)

range

11121314

MeasurementRange

± 199.99mV± 1.9999V± 19.999V± 199.99V

Display

offset ± 19999full scale ± 19999

InputProtection

± 50V± 50V

± 250V± 250V

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.2% of rdg + 2 digit)

range

22232425

MeasurementRange

± 1.9999mA± 19.999mA± 199.99mA± 1999.9mA

Display

offset ± 19999full scale ± 19999

InputProtection

± 50mA± 50mA

± 3A± 3A

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.2% of rdg + 20 digit)

range

11121314

MeasurementRange

199.99mV1.9999V19.999V199.99V

Display

offset ± 19999full scale ± 19999

InputProtection

50V50V250V250V

Frequency range : 40Hz to 1kHzResponse time : Approx 1 sec (10% to 90%)Dead band : 100 digit

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.5%of rdg + 20 digit)

range

232425

MeasurementRange

19.999mA199.99mA1999.9mA

Display

offset ± 19999full scale ± 19999

InputProtection

50mA3A3A

Frequency range : 40Hz to 1kHzResponse time : Approx 1 sec (10% to 90%)Dead band : 100 digit

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.1% of rdg + 3digit)± (0.2% of rdg + 3digit)

range

1V2V

MeasurementRange

1 to 5V4 to 20mA

Display

Offset : ± 19999Fullscale ± 9999

InputProtection

± 50V± 50mA

Excitation power supply : 24VDC ± 10% 30mA

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.5% of FS)± (0.2% of FS)± (0.2% of FS)± (0.6% of FS)± (0.4% of FS)± (0.4% of FS)

± (0.4% of FS) applied over 500°C

range

KAKBJTSRB

Sensortype

KKJTSRB

MeasurementRange

-50.0 to 199.9°C-50 to 1200°C-50 to 1000°C-50 to 400°C0 to 1700°C

-10 to 1700°C100 to 1800°C

MaximumResolution

0.1°C1°C1°C1°C1°C1°C1°C

Cold junction compensator accuracy : ± 2°C (10 to 40°C)Sensor lead resistance : less than 50ΩLinearzing method : Digital linearizingBurn out alarm : - - - - -

Thermocouple • RTD

A83 C-0 (Thermocouple)

A83 D-0 (RTD)

Output Specification

BCD outputType of output: Open collector or TTLLogic: ChangeableOutput rate: DC30V 10mA (open collector)

Funout 2 (TTL)

External ControlHold: Shorted HOLD terminal and COM terminal or

equipotential, Hold ONDigital Zero: Shorted DZ terminal and COM terminal or equipotential,

Digital zero ONPeak Hold: Shorted PH terminal and COM terminal or equipotential,

Peak hold ON

Common Specification

Display: Red LED 10mm heightMaximum display: -19999 to 19999Conversion rate: 20times/secOverrange indication: When input exceed the maximum

display display OL or -OLZero display: Leading zero suppressionDecimal point: Settable to any digit positionOperating temp: 0 to 50°C (35 to 85% RH)Storage temp: -10 to 70°Cless than 60%RHPower supply: 5V to 12VDC, 12V to 24VDC Power consumption: Appro x 1.5WDimensions: 48mm (W) x 24mm (H) x 96mm (D)

DIN sizeWeight (unit only) : Appro x 100gDielectric strength: Power supply/input terminal/output

terminal/external control DC500V/minInput terminal/output terminal/external control DC500V/minCase/each terminal AC1500V/min

Insulation resistance: DC500V more than 100MΩ at the above terminals

Accuracy(23°C ± 5°C, 35 to 85%RH)

± (0.15% of FS)± (0.3% of FS)

range

PAPB

Sensor type

PT100ΩPT100Ω

MeasurementRange

-100.0 to + 199.9°C-100 to + 600°C

MaximumResolution

0.1°C1°C

available Fahrenheit display

Page 18: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

Ordering Code

Dimensions

ASAHI KEIKI CO.,LTD.

With sheet switch48.0

24.0

Without sheet switch48.0

24.0

89.1

3.5

Front View

SideView

A8 – 0Option 1. none

2. BCD (TTL), external control3. BCD (Open collector), external control

Input

Front sheet

Power supply

1. DC voltage2. DC current4. AC voltage5. AC currentB. ProcessC. ThermocoupleD. RTD

1. with sheet switch2. without print sheet swtich

3. 5V to 12VDC4. 12V to 24VDC

Printed in Japan, Jun. 2005 (KP)

We reserve the right to change specifications without notice.

3rd Fl., Ehara Bldg., 5-7, Kaji-cho 1-chome, Chiyoda-ku, Tokyo 101-0044, JapanTEL:+81-3-3251-5576FAX:+81-3-3251-5567http:// www.asahikeiki.co.jpE-mail: [email protected]

UNIVERSAL TYPE DIGITAL PANEL METERA8000

Page 19: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1
Page 20: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1
Page 21: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1
Page 22: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

ASAHI KEIKI CO.,LTD.

Proc

ess

Mon

itor

Ordering Code

Dimensions

Connection Diagram

LOHIOV +5V

D.P

COM

Connect input Lo and Ov.

Power

INPUT

HO

LD

1 2 3 4 5 6 7 8 9 10

101 102 103

48

73

514.8

24

Fullscale Adjust

Offset Adjust

Min.65

Min

.3522

.2+

0.3

–0

45+0.6–0

Front

Panel thickness 0.8 to 3.2mm

Side

Panel Cutout

AS-201 -

1V2V3VRange

DC Voltage Measurement

Accuracy: ±0.1% rdg ±2 digit (23°C ±5°C)

SpecificationsInput Configuration: Single EndedInput Bias Current: 2nA(Typ.)Conversion Rate: 2.5/secNormal Mode Rejection: 40dB Typ. (50/60Hz)Temperature Coefficient: ±0.1 digit (Typ.)/°C

±0.3 digit (Max.)/°CDisplay: LED, 10.2mm 3 1/2 digitPolarity: 1V Range:When input less than 1V, a "-" is

displayed automatically.2V, 3V Range:When input less than 0V, a "-"is displayed automatically.

Decimal Point: Settable to any digit positionOverrange Indication: When input exceeds the maximum display,

1999 flashesFull-scale Adjustment: 100~1999External Hold: Negative 0V or ShortPower Supply: DC 5V±5% 70mA (Typ.)Operating Temperature: 0~50°C, 35 to 85%RHPower Consumption: 350mWDimensions: 24(H) 48(W) 73(D)mm DIN SizeWeight: 40gDielectric Strength: Between Input(Lo) and Mounted panel,

AC1500V/1 min.Insulation Resistance: DC500V 100MΩ or more at above terminals

1~5V0~5V

0~10V

Model Code RangeInput

ImpedanceInput

Protection

AS-201-1VAS-201-2VAS-201-3V

1MΩ1MΩ1MΩ

±250V±250V±250V

0-100~19990-100~19990-100~1999

DisplayAdjustable

PROCESS MONITORAS-201

Features• Adjustable full scale

• Bright LED 10.2mm

• Din size 24(H) 48(W)

• 1-5V, 0-5V, 0-10V measurement

• Power supply DC5V (NO-ISOLATED)

Fullscale Adjustable

Page 23: DIGITAL PANEL METER · ASAHI KEIKI CO.,LTD. DIGITAL PANEL METER A1000 Model Code A1 1 - Range Power Supply 1. 90 to 132 VAC 2. 180 to 264 VAC 3. 5 to 24 VDC ±10% Input: 1

ASAHI KEIKI CO.,LTD.

PROCESS MONITORAS-243

Standard 4 1/2 Digit

Dimensions

Connection Diagram

Front

Side

Panel Cutout

Panel thickness 0.8 to 3.5mm

24

48

87

655

45

Min.65

Min

.35

+0.6-0

22.2+

0.3

-0

1 2

LOHI NC NC NCNCCOMS/H - +

DC POWERINPUT

3 4 5 6 7 8 9 10

Features

•Easily adjustable offset-fullscale (Span 10000 counts)

•Bright LED, 8 mm (Red)

•DIN size 24 (H) 48 (W) mm

•Power supply DC 24 V (isolated)

•1-5 V, 0-5 V, 0-10 V, 4-20 mA measurement

DC Voltage Measurement

General SpecificationsInput configuration : Single endedInput bias current : 2 mA (TYP.)Conversion rate : 2.5/secNormal mode rejection : 50dB (TYP.) (50/60 Hz)Temp. coefficient : Offset display ±0.5 digit/˚C

Fullscale display ±0.01% of span/˚COverrange indication : When input exceeds the maximum display,

display flashesFullscale adjustment : 100 to 9999Offset a djustment : ±5000Span : 10000 countsDisplay : LED, 8 mm (Red)Polarity : A "-" is displayed automaticallyScaling : By switch (rear) and fine volume (front)Hold : COM and S/H terminal shortedDecimal point : Settable to any digit positionOperating temperature : 0 to 50˚C 35 to 85%RHPower supply : DC24V±20%Power consumption : 30 mA at DC24VDimensions : 24(H) 48(W) 87(D)mm DIN sizeWeight (unit) : Approx. 50gDielectric strength : Between input (Lo) and mounted panel, AC

1500V/l min.Between input (Lo) and power supply (0V), DC500 V/l min.

Insulation resistance : DC 500 V 100 MΩ or more at the aboveterminals

Accessory : Connector, Instruction manual

Model Range Display Input Impedance Input ProtectionAS-243-1V 1-5 V Offset ±5000 1MΩ ±250VAS-243-2V 0-5V fullscale 1MΩ ±250VAS-243-3V 0-10 V 100 to 9999 1MΩ ±250V

Accuracy: ±(0.1%of rdg+2 digit) (23˚C±5˚C 45~75%RH)

DC Current MeasurementModel Range Display Internal Resistance Input Protection

AS-243-2A 4-20mA Offset ±5000 50Ω ±50mAfullscale100 to 9999

Accuracy: ±(0.1% of rdg+2 digit) (23˚C±5˚C 45~75%RH)

Ordering Code

AS-243 4-