6
Digital gauge DK Series Intelligent network system MG40 Series Multi point measuring unit MG10/20/30 Series DK MG & SERIES SERIES DIGITAL GAUGE Network interface The contents of this literature are as of Jul. 2011 This catalog is printed with soy ink. MGS-DKMG-1107-EN-C http://www.mgscale.com Shinagawa Intercity Tower A-18F, 2-15-1, Konan, Minato-ku, Tokyo 108-6018, JAPAN Magnescale Co., Ltd. Headquarters Tokyo Office Nagoya Office Osaka Office International Sales Department Magnescale Americas Inc. Magnescale Europe GmbH 45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan 45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan 2-35-16, Meieki, Nakamura-ku, Nagoya Aichi, 450-0002, JAPAN 2-14-6, Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN 45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan 5740 Warland Drive, Cypress, CA 90630, USA Antoniusstrasse 14, 73249 Wernau, Germany TEL.+81 (0)463-92-1011 TEL.+81 (0)463-92-7972 TEL.+81 (0)52-587-1823 TEL.+81 (0)6-6305-3101 TEL.+81 (0)463-92-7971 TEL.+1 (562) 594-5060 TEL.+49 (0) 7153 934 291 FAX.+81 (0)463-92-1012 FAX.+81 (0)463-92-7978 FAX.+81 (0)52-587-1848 FAX.+81 (0)6-6304-6586 FAX.+81 (0)463-92-7978 FAX.+1 (562) 594-5061 FAX.+49(0) 7153 934 299 E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] : : : : : : :

DIGITAL GAUGE DK - Amazon Web Services

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DIGITAL GAUGE DK - Amazon Web Services

Digital gaugeDK Series

Intelligent network systemMG40 Series

Multi point measuring unitMG10/20/30 Series

DK

MG&

SERIES

SERIES

DIGITAL GAUGE

Network interface

The contents of this literature are as of Jul. 2011This catalog is printed with soy ink.MGS-DKMG-1107-EN-C

http://www.mgscale.com

Shinagawa Intercity Tower A-18F, 2-15-1, Konan, Minato-ku, Tokyo 108-6018, JAPAN

Magnescale Co., Ltd.

HeadquartersTokyo OfficeNagoya OfficeOsaka OfficeInternational Sales DepartmentMagnescale Americas Inc. Magnescale Europe GmbH

45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan2-35-16, Meieki, Nakamura-ku, Nagoya Aichi, 450-0002, JAPAN2-14-6, Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan5740 Warland Drive, Cypress, CA 90630, USAAntoniusstrasse 14, 73249 Wernau, Germany

TEL.+81 (0)463-92-1011TEL.+81 (0)463-92-7972TEL.+81 (0)52-587-1823TEL.+81 (0)6-6305-3101TEL.+81 (0)463-92-7971TEL.+1 (562) 594-5060TEL.+49 (0) 7153 934 291

FAX.+81 (0)463-92-1012FAX.+81 (0)463-92-7978FAX.+81 (0)52-587-1848FAX.+81 (0)6-6304-6586FAX.+81 (0)463-92-7978FAX.+1 (562) 594-5061FAX.+49(0) 7153 934 299

E-mail: [email protected]: [email protected]: [email protected]: [email protected]: [email protected]: [email protected]

:::::::

Page 2: DIGITAL GAUGE DK - Amazon Web Services

DK805AFLR/DK805BFLRDK805AFLR5/DK805BLFR5

DK805ALR/DK805BLRDK805ALR5/DK805BLR5

DK10

DK25

DK50

DK100

DK155/DK205DK155 shown

DK802

DK812

【NEW】DK830S

SERIES

DIGITAL GAUGE

2 3

Achieved over 20 million strokesin current testing

(DK830SR, DK830SLR)

Ball spindle bearing design reduces the affect of side loadon accuracy and durability

(DK830S series)

Slim and compact design withhigh performance

■Measurement range : 2 - 205 mm

■Accuracy : 1µm to 1.5µm (DK800 Series)

■Maximum resolution : 0.1µm, 0.5µm

■Maximum response speed:

 80m/min. (at Max. resolution of 0.1µm)

 250m/min.(at Max. resolution of 0.5µm)

■Built-in reference point

■Highly resistant against water and oil,

 and excellent durability

■Available in spring push

The DK Series digital gauge with its slim and

compact design offers exceptional

performance of 0.1um resolution and

80m/minute response speed. Magnescale

magnetic technology, along with the use of

stainless steel components, allows the gauge

to perform with accuracy and durability even

under the harshest environments.

Long stroke mm30

High resolution μm

High response speed m/min800.1

Wide measurement range 2 to 205 mmAll measurements can be realized by wide range lineup

Page 3: DIGITAL GAUGE DK - Amazon Web Services

SERIES

Network interface

4 5

Ethernet or CC-Link models available

MG42MG41-NC

MG43

PLC

CC-LINK

MG42MG41-NE

MG43

Ethernet

FA computer

MG43

MG41-NE / MG41-NC / MG42-4MG10 / 20 / 30

BCD

RS-232C

Standard function: RS232C

PLC

PC

MG10 / 20 / 30

■The MG40 series, with its standard Ethernet interface, enables you to process and store remote data via 100Mbit/sec high speed data communication.

■Utilizing a single MG41 hub, up to 100 channels can be easily connected via one network cable.

■Ethernet and CC-Link interfaces eliminate the need for BCD or RS-232C wiring connections.

■In the event of a communication error, the system automatically aquires the correct positional information.

■Bi-directional serial digital communication allows for a higher response speed.

■DIN rail compatible (35mm)

The MG40 series intelligent network measurment system enables high-speed communication, multi-channel measurement and data

management. The MG40 series communicates with the DK series of gauges via a true digital communication protocol and does not rely upon

analog or AB phase outputs. Miscounts caused by external noise are eliminated and the system instantly recovers from communication errors.

■Up to 16 expansion modules can be connected to each MG10 main module

■Maximum 64 channels possible by link connection

■Available input resolutions of 0.1um, 0.5um, 1um, 5um, or 10um

■Standard RS-232C interface, BCD output also available

■DC12V - 24V operating voltage

■Din rail compatible (35 mm)

This modular measurement system is applicable to multi-channel measurement via RS232C or BCD

communication. The MG10 series allows multi-channel input to a PC or PLC through one main hub

reducing wiring and increasing efficiency.

Intelligent Network system Modular Measurement Unit

The MG40 series is an intelligent networkinterface system designed for highlyefficient multi-channel measurement For multi-channel measurment

Wide measurement range from 2 mm to 205 mmallows for a broad range of applications

Page 4: DIGITAL GAUGE DK - Amazon Web Services

Vacuum suction (DK802ALR / DK802ALR5 / DK802BLR / DK802BLR5)

100 m/s2

1000 m/s2

IP66 (not including interpolation box and connectors)

0˚C to 50˚C/32˚F to 122˚F

–20˚C to 60˚C/–4˚C to 140˚C

DC +5 V ±5%

1 W

2.5 m/8.2'

Approx. 20 g/0.7 oz

+P M4x5 screw (2pcs.). Installation spacer, Instruction Manual, Supplement

22 m/72.2' max.

A/B/REF differential TTL output (compliant with EIA-422)

2 mm (0.08")

One location (at 1 mm/0.04" position of spindle movement)

ModelDK802BR, DK802BLR DK802AR5, DK802ALR5 DK802BR5, DK802BLR5

High resolution type General purpose type

DK802AR, DK802ALR

*1: The mass indicated is the total mass excluding the cable and interpolation box.

Output

Resolution

Measuring range

Accuracy (at 20˚C / 68˚F)

Measuring force (at 20˚C / 68˚F)

Reference point

Maximum response speed

Air driving

Vibration resistance (10 to 2000 Hz)

Impact resistance (11 ms)

Protective structure

Operating temperature

Storage temperature

Power supply voltage

Power consumption

Cable length

Diameter of stem

Mass*1

Feeler

Accessories

Output cable length(up to the electronic section)

0.1 µm

1 µm

0.5 µm

1.5 µm

Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Provided with a steel ball tip Mount screw M2.5

80 m/min 250 m/min 100 m/min42 m/min

ø8 / 0.31”dia.

Specifications

Downward: 0.45 ± 0.25 N Horizontal: 0.40 ± 0.25 N Upward: 0.35 ± 0.25 N

DK802

Vacuum suction (DK812AFLR / DK812AFLR5 / DK812BFLR / DK812BFLR5)

Pneumatic push type (DK812AVR / DK812AVR5 / DK812BVR / DK812BVR5)

100 m/s2

1000 m/s2

IP66 (not including interpolation box and connectors)

0˚C to 50˚C/32˚C F to 122˚F

–20˚C to 60˚C/–4˚CF to 140˚F

DC +5 V ±5%

1 W

2.5 m/8.2'

φ9.5/0.37” dia. (Flange type), φ8/0.31” dia. (others)

Approx. 30 g/1.06 oz

+P M4x5 screw (2pcs.). Installation spacer, Instruction Manual, Supplement

22 m/72.2' max.

A/B/ phase voltage-differential line driver output (compliant with EIA-422)

12 mm (0.47")

One location (at 1 mm/0.04" position of spindle movement)

Model DK812BR, DK812BLR, DK812BFR,DK812BFLR, DK812BVR

DK812AR5, DK812ALR5, DK812AFR5,DK812AFLR5, DK812AVR5

DK812BR5, DK812BLR5, DK812BFR5,DK812BFLR5, DK812BVR5

High-resolution models General-purpose resolution models

DK812AR, DK812ALR, DK812AFR,DK812AFLR, DK812AVR

*1 : Please refer to P10 DK 802 A/B about the extension cable (Option). *2 : The mass indicated is the total mass excluding the cable and interpolation box.

Output

Resolution

Measuring range

Accuracy (at 20˚C / 68˚F)

Reference point

Maximum response speed

Vibration resistance (10 to 2000 Hz)

Impact resistance (11 ms)

Protective structure

Operating temperature

Storage temperature

Power supply voltage

Power consumption

Cable length*2

Diameter of stem

Mass*1

Feeler

Accessories

Output cable length(up to the electronic section)

Measuring force(at 20˚C / 68˚F)

0.1 µm

1 µm

0.5 µm

1.5 µm

Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Provided with a steel ball tip Mount screw M2.5

80 m/min 250 m/min 100 m/min42 m/min

Specifications

Downward : 0.6 ± 0.3 NHorizontal : 0.5 ± 0.3 N

Upward : 0.4 ± 0.3 NAir pressure of 0.03Mpa : 1N or less in all directions

Air pressure of 0.04Mpa : 1.7N or less in all directions

Air driving

DK812

6 7

DK830SVR

ø13.

6/ø0

.54

ø17.

9/ø0

.70

ø24.

3/ø0

.96

ø34.

1/ø1

.34

ø4ø8ø12 8.6 45.7

154/6.06

Adoption tube ø4/ø0.16ø4.8/ø0.19 ø8/ø0.31

10.2/0.40138.4/5.45

DK830SR

ø4.8

/ø0

.19

ø8.2

/ø0

.32

17/0.67

(28/

1.10

)

110/4.33

t=15.5(101/3.98)300/11.81

Cable length 2400/78.74

2-ø4.5/Mountin

g hole

ø5.8

/ø0.

23

ø4.8

/ø0.

19

ø4/ø

0.16

ø8/ø

0.31

ø12/

ø0.4

7

39.6/1.56 45.7/1.80

195.2/

DK830SLR

ø13.

6/ø0

.54

ø17.

9/ø0

.70

ø24.

3/ø0

.96

ø34.

1/ø1

.34ø4

/ø0.

16ø8

/ø0.

31ø1

2/ø0

.47

39.6/1.56 45.7/1.80

185/7a.2888.4 39 26

ø4.8/ø0.19

10.2/0.40

169.4/6.67

【NEW】DK830

Measuring rangeResolutionAcucracy(at 20˚C / 68°F)

Measuring force

Operating tempertureStrage tempertureMaximum response speedRefence response speedAir drivingReference point positionProtective design grade (Note1)Vibration resistanceImpact resistanceCable lngthDiameter of stemFeelerPower supply voltagePower consumptionMass (Note3)OutputGaranteed number of strokesOutput cable length(up to the electronic section)Accessiries

Model DK830SR DK830SLR

IP53/IP67 (Note2)IP53

DK830SVR

1.7 μm

Pneumatic push type

Approx. 80 g

10 million or more

Air presser 0.07 Mpa 1.9 N or less for all diectionAir presser 0.09 Mpa 2.6 N or less for all diection

Specifications

Note1: Except interpolation box and connector Note2: Bellows set(Option accessory) Note3: Except cable and interpolation box Note4: According to the evaluation method of Magnescale.

30 mm0.1 μm

0 to 50˚C-20 to 60˚C80 m/min80 m/min

One point at 1mm spindle move

10 to 2kHz 100 m/s2

1000 m/s2 11 msApprox. 2.4 m

φ8Provided with a carbide tip, Mounting screw M2.5

DC 5 V±5 %1 W

A/B/REF voltage-differential line driver output (compliant with EIA-422)

22 m MAXSpanner, Instruction manual, Supplimanet, +P M4x5 screw(2 pcs.)

1.3 μmUpward: 0.5 ±0.35 N

Horizontal: 0.6 ±0.35 NDownward: 0.7 ±0.35 N

non

Approx. 70 g

20 million or more

3957.3 26

3988.4 26

DK812ALR/DK812ALR5/DK812BLR/DK812BLR5

ø10/

ø0.3

921

/0.8

3

ø9/ø0.3529.7/1.17 18/0.71

87/3.43

97/3.82

105/4.13

6

DK812AVR/DK812AVR5/DK812BVR/DK812BVR5

ø10/

ø0.3

9

21/0

.83

18/0.71 ø9/ø0.35170.67

(94.4/3.72)

105/4.13

(107.1/4.22)

92.3/3.68

DK812AFLR/DK812AFLR5/DK812BFLR/DK812BFLR5

8/0.315.8/0.23 4.2/0.17

ø12/

ø0.4

7M9

ø10/

ø0.3

9

21/0

.83

ø9/ø0.35

29.7/1.17

105/4.13

97/3.82

87.5

6

DK812AFR/DK812AFR5/DK812BFR/DK812BFR5

5.8/0.238/0.31

ø12/

ø0.4

7M9

4.2/0.17

105/4.13

29.7/1.17

6

DK812AR/DK812AR5/DK812BR/DK812BR5

Cable length 2000/78.74

Cable length 300/11.81 (101/3.98)

ø4.8

/ø0.

19

105/4.13

ø80 −0.

00,9

35.5/1.4

29.7/1.17 18/0.71

6

(28)

92-ø4.2

ø8.5

Thickness 15.2

-0.0

004

0-0

.009

0

/ø0.

37

ø9.5

ø9.5

/ø0.

37(S

tem

)

DK802AR/DK802AR5/DK802BR/DK802BR5

64.2/2.53

8.6/0.3412.2/0.48

DK802ALR/DK802ALR5/DK802BLR/DK802BLR5

56.2/2.21

ø9/ø0.35

21/0

.83

ø10/

ø0.3

9

46.2/1.82

8.6/0.3412.2/0.48

64.2/2.53

Option : Extension cable

13/0

.51

Cable length 1,3,5,10m (39.37"/118.11"/196.85"/393.70")

ø11.

8/ø0

.46

ø10/

ø0.3

9

41.5/1.63

13/0.51 13.6/0.54

14/0.555.5/0.225.5/0.22 30.5/1.2

49.5/1.9535.5/1.4

6.2/0.24 24.3/0.964.8/0.16 13

.6/0

.54

(CK-T12:1m/3.3’, CK-T13:3m/9.8’, CK-T14:5m/16’, CK-T15:10m/32.8’)

13.6

/0.5

4 Cable length 1,3,5,10m

50/1.9741.5/1.63

55.5/2.19

Option : Extension cable(CE22-01:1m/3.3’, CE22-03:3m/9.8’, CE22-05:5m/16’, CE22-10:10m/32.8’)

+VccSignal Cable color

RedWhiteBlue

YellowOrange

GrayGreenViolet

0VAABBZZ

(39.37"/118.11"/196.85"/393.70")

Unit : mm/inch

Unit : mm/inch

Model DK805AFR5, DK805AFLR5,DK805AR5, DK805ALR5

DK805BFR5, DK805BFLR5,DK805BR5, DK805BLR5

DK805BFR, DK805BFLR,DK805BR, DK805BLR

DK805AFR, DK805AFLR,DK805AR, DK805ALR

Output

Resolution

Measuring range

Accuracy (at 20˚C/68˚F)

Measuring force(at 20˚C/68˚F)Reference point

Maximum response speed

Air driving

Shock resistance (11 ms)

Protective structure

Operating temperature

Storage temperature

Power supply voltage

Power consumption

Cable length*1

Diameter of stem

Mass*2

Feeler

AccessoriesOutput cable length(up to the electronic section)

Vibration resistance(10 to 2000 Hz)

A/B/ phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference.

Vacuum suction ( DK805AFLR / DK805AFLR5 / DK805BFLR / DK805BFLR5 / DK805ALR / DK805BLR / DK805ALR5 / DK805BLR5 )

100 m/s2

1000 m/s2

IP66 (not including interpolation box and connectors)

0˚C to 50˚C/32˚F to 122˚F

-20˚C to 60˚C/-4˚F to 140˚F

DC +5 V ±5%

1 W

2.5 m/8.2'

ø9.50 /0.37" dia.

Approx. 30 g/1.06 oz

Installation spacer, Instruction Manual, Supplement

22 m/72.2' max.

5 mm (0.19")

Downward: 0.45 ± 0.25 N Horizontal: 0.40 ± 0.25 N Upward: 0.35 ± 0.25 NOne location (at 1 mm/0.04" position of spindle movement)

0.1 µm

1 µm

0.5 µm

1.5 µm

Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Provided with a steel ball tip Mount screw M2.5

80 m/min 42 m/min 250 m/min 100 m/min

High-resolution models General-purpose resolution model

*1 : Please refer to P10 DK 802 A/B about the extension cable (Option).*2 : The mass indicated is the total mass excluding the cable and interpolation box.

0-0.009

0-0.0004

Specifications

DK805

DK805AFR/DK805BFRDK805AFR5/DK805BFR5

DK805ALR/DK805BLRDK805ALR5/DK805BLR5

DK805AR/DK805BRDK805AR5/DK805BR5

DK805AFLR/DK805BFLRDK805AFLR5/DK805BFLR5

79.6/31.3

21.2/0.83

0 −0.0

09/

0 −0.0

04ø8

/0.3

1

0.34/8.6

21.2/0.83

71.6/31.3

0 −0.0

09/

0 −0.0

04

ø95

ø0.3

7

4/0.265.3/0.218.7/0.34

M9xP0.5

4-ø2.1 deep2.5/ø0.08 deep0.1

ø12/

0.47

79.6/31.3

71.6/2.82

21.2/0.83

61.6/2.43

8.7/0.345.3/0.21 4/0.16

0 −0.0

09/

0 −0.0

04

ø9.5

ø0.3

7

M9xP0.5

4-ø2.1 deep2.5/ø0.08 deep0.1

ø12/

0.47

21/0

.83

ø9/ø0.35

ø10/

ø0.3

9

21.2/0.83 0.34/8.6

0 −0.0

09/

0 −0.0

04ø8

/0.3

1

21/0

.83ø1

0/ø0

.39

79.6/3.13

61.6/2.43

71.6/2.82

ø9/ø035

Unit : mm/inch

Unit : mm/inch

Page 5: DIGITAL GAUGE DK - Amazon Web Services

8 9

DK50/100/155/205

Model

Output

Resolution*1

Measuring range

Accuracy (at 20˚C)

Specifications

Upward

Horizontal

Downward

Measuringforce(at 20˚C)

Reference point

Maximum response speed

Vibration resistance (10 to 2000 Hz)

Impact resistance (11 ms)

Protective structure

Operating temperature

Storage temperature

Power supply voltage

Power consumption

Cable length*2

Diameter of stem

Mass*3

Feeler

Output cable length

Guaranteed number of Strokes

Accessories

DK50NR5 DK50PR5 DK100NR5 DK100PR5 DK205DK155

50 mm

2 µm

100 mm

4 µm

155 mm

5 µm

205 mm

6 µm

0.9 ± 0.4 N

1.3 ± 0.5 N4.9 N or less

1.8 ± 0.65 N

2.7 ± 0.55 N4.9 N or less

Approx. 2.2N (by mass of spindle)

Approx. 2.2N (by mass of spindle)

A/B/ phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference.

0.5 µm

One location (at 1 mm position of spindle movement)

250 m/min

150 m/s2

1500 m/s2

0˚C to 50˚C

-20˚C to 60˚C

DC +5 V ±5%

1 W or less

Approx. 2.5 m

ø 20 mm0 -0.013

22 m max.

Minimum 5 million cycles without shock

+P M4x5 screw (2 pcs.), Instruction Manual

IP50 IP50 IP64IP64

Approx. 360 g Approx. 1100 g Approx. 1300 gApprox. 630 g

Provided with a carbide ball tip DZ-122 (Mount screw M2.5) Magnetic substanceProvided with a carbide ball tip DZ-121 (Mount screw M2.5)

*1 : The resolution setting needs to be made when connecting to the LT30 series, MG series, and LY70 series. For details, please refer to the respective instruction manual.*2 : Please refer to P10 DK 802 A/B about the extension cable (Option). *3 : The mass indicated is the total mass excluding the cable and interpolation box.

0 -0.05ø 32 mm

0 0 0-0.0

02/ø

1.26

-0.0

5 0

ø32

-0.0

02/ø

1.26

-0.0

5ø3

2

(20/0.79)

ø5.8

/ø0.

23

ø22

/ø0.

87

9/0.35

ø8 /ø0.

31

28/1.1

(ste

m)

416/16.38 ~ 571/22.48

407/16.02

DK155PR5

DK205PR5

-0.002 0/ø1.26-0.05 0ø32

(20/0.79)

ø5.8

/ø0.

2328/1.1

-0.002 0/ø1.26-0.05 0ø32

(stem)

ø22

/ø0.

87

9/0.35

ø8 /ø0.

31

516/20.31 ~ 721/28.39

507/19.96

-0.0

040

-0.0

13 0

-0.0

005

0

-0.10

12/0.47 (20/0.79)

ø5.8

/ø0.

23

ø20

/ø0.

79(s

tem

)

ø0.9

8ø2

5

ø8 /ø0.

31

(102/4.02)2.5/0.1 38.5/1.52

329/12.95443.5/17.46

DK100NR5/PR5DK50NR5/PR5

ø6 /ø0.

24 -0.0

13 0

ø20

-0.0

005

0/ø

0.79

(ste

m)

-0.0

03 0

.000

8/ø

0.78

(ste

m)

-0.0

7-0

.02

ø20

12/0.47 51/2.01 44/1.73223/8.78

286/11.26 (20/0.79)

ø5.8

/ø0.

23

Model

*1 : The resolution setting needs to be made when connecting to the LT30 series, MG series, and LY70 series. For details, please refer to the respective instruction manual.*2 : Please refer to P10 DK 802 A/B about the extension cable (Option). *3 : The mass indicated is the total mass excluding the cable and interpolation box.

Output

Resolution*1

Measuring range

Accuracy (at 20˚C)

Specifications

DK10PLR5

ø5.8

/ø0.

23

102.5/4.04

12.3/0.48

ø22/ø0.87

79/3.1126.3/1.0352.7/2.07

-0.0

7-0

.02

ø20-0

.013

0ø2

0 -0.0

005

0/ø

0.79

-0.0

030.

0008

/ø0.

79

21.3/0.84

(ste

m)

12/0.47

(11.5/0.45)

ø6/ø

0.24

37/1

.46

69.5

/2.7

4

(20/

0.79

)

*Please refer to p54 forthe details of the screw.

DK25NLR5/PLR5

12/0.47

160/6.3

(26.5/1.04)121.5/4.78

95.2/3.75 26.3/1.0433.8/1.33

ø6/ø

0.24

-0.0

130

ø20 -0

.000

50

/ø0.

79(s

tem

)

-0.0

7-0

.02

ø20 -0

.003

0.00

08/ø

0.79

12.3/0.48

ø22/ø0.87

Cable length2500/98.42

37/1

.46

69.5

/2.7

4

(20/

0.79

)

-0.0

130 -0

.000

50 -0.0

7-0

.02

-0.0

030.

0008

ø20

/ø0.

79(s

tem

)

ø20

/ø0.

79 Cable length 2500/98.42

ø6/ø

0.34

12/0.47

(11.5/0.45)21.3/0.84

98.5/3.88122/4.81

(20/0.79)

ø5.8

/ø0.

23

DK10NR5/PR5 DK25NR5/PR5

(20/0.79)

Cable length 2500/98.42

ø5.8

/ø0.

23

-0.0

130

ø20 -0

.000

50

/ø0.

79(s

tem

) -0.0

7-0

.02

ø20 -0

.003

0.00

08/ø

0.79

ø6/ø

0.24

12/0.47 (26.5/1.04)33.8/1.33

141/5.55179.5/7.07

DK10/25

Upward

Horizontal

Downward

Measuringforce(at 20˚C)

Impact resistance (11 ms)

Protective structure

Operating temperature

Storage temperature

Power supply voltage

Power consumption

Cable length*2

Diameter of stem

Mass*3

Feeler

Output cable length

Guaranteed number of Strokes

Accessories

Reference point

Maximum response speed

Vibration resistance (10 to 2000 Hz)

0.3 ± 0.25 N

0.6 ± 0.3 N

0.8 ± 0.35 N4.9 N or less

150 m/s2

1500 m/s2

10 mm 25 mm

Approx. 230 g Approx. 300 g

4.9 N or less 4.9 N or less

IP50

DK10NR5

0.4 ± 0.3 N

0.7 ± 0.35 N

1 ± 0.4 N

IP50

DK25NR5

0.4 ± 0.3 N

0.7 ± 0.35 N

1 ± 0.4 N

IP50IP64 IP64 IP64

DK25NLR5 DK25PLR5DK25PR5DK10PLR5DK10PR5A/B/ phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference.

0.5 µm

2 µm

One location (at 1 mm position of spindle movement)

250 m/min

0˚C to 50˚C

-20˚C to 60˚C

DC +5 V ±5%

1 W

Approx. 2.5 m

ø 20 mm0 -0.013

Provided with a carbide ball tip DZ-122 (Mount screw M2.5)

22 m max.

Minimum 5 million cycles without shock

+P M4x5 screw (2 pcs.), Instruction Manual

DK Series measuring unit output signals

A

B

REF

The signals output from this measuring unit are A/B quadrature signal, Z signal in the form of voltage-differential line driver output compliant with EIA-422.

Before using, check that the minimum input phase difference of the control device connected to this measuring unit or the counter is smaller than 50 ns for the DK800A (A signal cycle: 200 ns, 5 MHz) or smaller than 100 ns for the DK800B (A cycle: 400 ns, 2.5 MHz). *The minimum phase difference can be modified under special specifications.

Before using, check that the minimum input phase difference of the control device connected to this measuring unit or the counter is smaller than 50 ns for-DK 10~110 series (A signal cycle: 200 ns, 5 MHz).*The minimum phase difference can be modified under special specifications.

The reference point signal is synchronized with A and B signal.

A

B

50 ns

200 ns (5 MHz)

DK800A output signals at maximumresponse speed (at approx. 80 m/min)

A

B

100 ns

400 ns (2.5 MHz)

DK800B output signals at maximumresponse speed (at approx. 42 m/min)

A

B

50 ns

200 ns (5 MHz)

DK10/25/100/110/155/205Output signals at maximum response speed (at approx. 42 m/min)

DK800 Series

The travel amount of the measuring unit is detected every 50 ns for the DK800A and every 100 ns for the DK800B, and the phase difference proportional to the amount traveled is output. The phase difference changes in integer multiples of 50 ns or 100 ns. Also, the minimum phase difference for the A and B is 50 ns for the DK800A and 100 ns for the DK800B.

A

B

Integer multiple of 50 ns or 100 ns

In maximum standard specifications, the minimum phase difference is fixed at 50 ns for the DK800A and 100 ns for the DK800B, but the minimum phase differences in the table below are available as special specifications.

100 ns DK800B standard product

50 ns DK800A standard product

300 ns Special specifications

500 ns

400 ns

200 ns

1.2 µs

2 µs

2.5 MHz

5 MHz

833 kHz

500 kHz

42 m/min

80 m/min

14 m/min

8.4 m/min

100 m/min

250 m/min

33 m/min

20 m/min Special specifications

A/B minimumphasedifference

Maximum response speed

Resolution 0.1 µm Resolution 0.5 µmRemarks

Counterallowablefrequency

A signalcycle

The travel amount of the measuring unit is detected every 50 ns, and the phase difference proportional to the amount traveled is output. The phase difference changes in integer multiples of 50 ns. Also, the minimum phase difference for the A and B is 50 ns.

Output Signal Phase Difference

A

B

Integer multiple of 50 ns

DK10/25/100/110/155/205

In the standard specifications, the minimum phase difference is fixed at 50 ns, but the minimum phase differences in the table below are available as special specifications.

100 ns

50 ns

300 ns

500 ns

A/B minimumphasedifference

100 m/min

250 m/min

33 m/min

20 m/min

Maximum response speedResolution 0.5 µm

Special specifications

Standard product

Special specifications

Special specifications

Remarks

2.5 MHz

5 MHz

833 kHz

500 kHz

Counterallowablefrequency

400 ns

200 ns

1.2 µs

2 µs

A signalcycle

Unit : mm/inch

Unit : mm/inch

If the response speed is exceeded, the A/B output from this measuring unit changes to Hi impeadance for about 400 ms to serve as an alarm.

Output Signal Alarm

Alarm section A/B is Hi impeadance

Receiver

DK10/25/100/155/205/110

(*If extending the cable, the supply voltage is +5 V±5%.) *Use the CE22 series extension cables for bare wires (optional accessories).

20 m or less

Line driver

Output: phase A/B/

*+V

0V

+V

AM26C32

DS34C87

0V

Line driver Line receiver AM26C32 or equivalentSIG

120

SIG*SIG

A

B

DK830S series model nameAvailable specification by option

DK830SR□□DK830SLR□□DK830SVR□□ 100 ns

50 ns(Standard)

300 ns

500 ns

A/B minimumphasedifference

Mark

-

B

C

D

0.5 µm

0.1 µm(Standard)

1 µm

Resolution Mark

-

05

10

A/B minimun phase diffence

A/B frequncy

Resolution

0.1 µm

0.5 µm

1 µm

Maximum response speed (m/min)

5.0 MHz

50 ns

80(Standard)

2.5 MHz

100 ns

42

100

200

0.8 MHz

300 ns

14

33

66

0.5 MHz

500 ns

8.4

20

40

Page 6: DIGITAL GAUGE DK - Amazon Web Services

Connectable measuring units

Connection cable length

Resolution

Measuring unit data import capacity

Comparator function

Reset function

Preset function

Datum point setting function

Reference point function

Master calibration function

Measuring unit product information

Item Description RemarksConditions

Measuring unit resolution(input resolution)

Comparator setting values

No. of setting value groups

Peak-hold function

Output data

Ethernet

Supply voltage

Command/setting enabledor disabled for eachcommunication line

Power consumption

Operating temperature and humidity range

Storage temperature and humidity range

Mass

Command

Data output

DC 12 to 24 V (11 to 26.4 V)

System total: Max. current 4 A

When the maximum current is exceeded, the connection can be enabled by providing a power supply to the MG42 hub units that come later in the connection.

<Details of power consumption for each unit> MG41 main unit : 4 W , MG42 hub unit : 1 W/unit , Measuring unit supply : 1 W/unit

0 to +50 ˚C (no condensation)

-10 to +60 ˚C (20 to 90 % RH)

MG41 : 300 g , MG42 : 250 g

Settings

Ethernet

Available

Reset function

Preset function

Datum point setting function

Reference point function

Master calibration function

Comparator value setting

Comparator group number setting

Start

Pause

Latch

Current value/Peak value (All axes)

Current value/Peak value (each unit)

Comparator result

Alarm (Communication/Measuring unit)

Soft ware version

Measuring unit product information

Input resolution

Display and output resolution

Axis addition

Comparator mode (2, 4, 8, or 16 values in 1 group)

CC−Link

Available

N/A

Available

0.1μm

-

0.5μm

0.5μm

1μm

1μm

5μm

5μm

2 values

16 groups

4 values

8 groups

8 values

4 groups

16 values

2 groups

10μm

10μm

Terminal input

Note the connectionconditions.

Entire system

MG41 main unit

MG42 hub unit

0.1μm

0.5μm

10 Mbps data transfer

Single axis

1 to 100 units (Connection disabled aft er connection of 101st unit.)

DK800A/DK 800B series, DK10, DK25, DK50, DK100, DK110, DK155, DK205

Settable output data resolution and display resolution

Maximum 10,000 data/s (when 100 axes are connected)

Calculation of maximum value, minimum value, and peak-to-peak value for each axis (including pause, latch, and start functions)

Peak value is not updated during pause.

Output and display data are not updated during latching (internal data is updated)

Recalculation of peak value is started by start function.

Current value, maximum value, minimum value, and peak-to-peak value for each axis

Data for each axis (single axis, addition/subtraction axis) is compared and measured, and the comparator results are output.(Comparator during latch is also latched.)

Current value for each axis is reset (by command).

Value is preset to the current value of each axis (by command).

Datum point of each axis can be set (by command).

Reference point can be used to relocate the datum point of each axis (by command).

Reference point can be used to perform master calibration for each axis (by command).

The product information of the connected measuring unit can be acquired.

0 to 4 axis

Between MG41 main unit and MG42 hub unit, between MG42 hubunit and MG42 hub unit: 0.5 m, 1 m, 2 m, 5 m, 10 m

Total cable length from MG41 main unit: Maximum 30 m(Maximum current: 4 A or less)

100Base-T (compliant with IEEE 802.3) 100 Mbps/10 Mbps (Auto-negotiation)Command input, data output, and parameter setting are possible.

Up to 24 connected MG42 hub units

The data for one axis is counted as one data.

Addition/subtraction axis cannot be used.

When master calibration function is not used

Use a power supply with a current that is4 A or higher.(Recommended: +24 V)(for every six MG42 hub units)

No. of connectablemeasuring units

Single axis calculation of an addition/subtraction axis isnot possible(for preventing inconsistencies in calculation).

Addition and subtraction Current value, maximum value, minimum value, and peak-to-peak value for the two-axis addition/subtraction axis

When master calibration function is not used

MG40 MG10/20/30 SERIESSpecifications

Specifications

Unit:mmUnit:mm

Main unitMG41-NC(CC-Link)

155

43

155

43

Main unitMG41-NE(Ethernet)

67.4 67.458

4032

.532

.5

4-M3 depth 8 or less

192.812.8

5525

25

2-M2depth 8 or less

2-M2depth 8 or less

7.3

105

55 92.6

71.7

16.5

6.2

16.8

6.2

7.3

8.5

12.8

25

26.9 4.3

258.

5

Display unitMG43

Item DescriptionCompatible main units

Compatible hub units

Compatible measuring units

Main functions

Communication protocol

Screen display

MG41-NE/MG41-NC

Hub units compatible with the main unit

Measuring units compatible with the main unit or hub unit

Measure Monitor, Setting Monitor, System Monitor

MG40 original protocol on TCP/IP

480 x 272 pixels, 4.3-inch TFT LCD with backlight

Item DescriptionNetwork interface

Power consumption

Power supply

Operating temperature range

Storage temperature and humidity range

Mass

100Base-TX / 10Base-T (compliant with IEEE802.3) Auto-negotiation

DC12~24V(11~26.4V)

4W

0 to +40°C (no condensation)

-10~+60˚C(20~90%RH)

Approx.500g

Hub unitMG42

155

43 69

�MG41、42 common

186 +10

93.5

+1 0

103

30

4-ø4.5

<MG43 Mounting the display unit form the panel front>

Model name

Power source

Communication

Linkage function

I / O

Connectable modules

Supply voltagePower consumptionInrush current (10ms)Power supply protectionCommunication I/FBaud rate settingData lengthStop bitParityDelimiterMaximum number of linkagesMaximum length of linking cable

DC12-24V(11-26.4V)Min. startup time: 100ms or less2.0W + total power consumption for connected modules*1

10A or less (when maximum number of modules are connected)Fuse (5A fuse is built in.)

RS-232C (EIA-232C or equivalent)2400 / 9600 / 19200 / 38400 bps (set with DIP switch)

7 / 8 bit (set with DIP switch)1 / 2 bit (set with DIP switch)

none / ODD / EVEN (set with DIP switch)CR / CR+LF (set with DIP switch)16 (total of counter modules: 64)

10m

Photo coupler insulation, external power: DC5 – 24V

Photo coupler insulation, external power: DC5 – 24Vreset, pause, start, latching, and data out trigger to whole channels

integrated alarmMG20-DK, MG20-DG and MG-20DT (available for mixed use, up to 16 modules) *1

MG30-B1,MG30-B2

Input formatsource input (+COM)

sink type (–COM)

sink input (–COM)

source type (+COM)

MG10-P1 MG10-P2

Output format

Main module

Input signalOutput signalCounter modulesInterface modules

Display unit MG43

*1 : Total power of modules connected to MG10 should not be over 54W (12VDC Input) or 108 W (24VDC Input).

*2 : Set the resolution value of the connected gauge. *3 : MG20-DG work only connect to DL**BR series

Model namePower consumption

Corresponding gauge

Maximum response speedReference point *3

MG20-DK MG20-DG MG20-DT1W + power consumption for connected gauge

DK series (A/B quadrature input)10 / 5 / 1 / 0.5 / 0.1µm

1.4W (connected to DG-B) / 0.5W (connected to DL-B)DG**B series, DL**B/DL**BR series

10 / 5 / 0.5µmset with DIP switch

S-ALM LED activates by excess speed/acceleration of measuring unit. C-ALM LED activates by excess speed of the internal circuit of counter.Alarm display is cancelled by reset command from MG10 or with the reset button of main unit.

0.8WDT series

5µm (DT12/32) 1µm (DT512)

100m / min–

Measuringunit input

Others Alarm

Subject to the specification of the connected gauge

Allowable resolution setting *2

REF-LED (reference point loaded) shows on the display after the reference point is detected. Set “0” or preset value on the counter when the reference point is detected.

Counter module

Model name

I/O

Output setting

source input (+com)

sink type (–com)

sink input (–com)

source type (+com)

1w

Photo coupler insulation, external power: DC5 – 24V

Photo coupler insulation, external power: DC5 – 24V DRQ / channel address / measuring mode shifting / comparator shifting / reset / start / posing / reference point loaded

BCD data (6 digits) / READY / code / GO/NO GO output / alarm / reference point loadedtimer (1~128ms) / OUT / OR / polarity (set with internal DIP switch)

Input format

Output format

Input signalOutput signal

All models Operating temperature Storage temperature

0~+50˚C (No condensation) –10~+60˚C (20~90%RH)

Interface module

Power consumption

MG30-B1 MG30-B2

“MG”Multi Interface unit operates with a variety of modules.

Counter module (MG20)• Digital gauge input• Resolution setting

Main module (MG10)• Power supply• RS-232C Connection• Connection with Counter module, I/F module

I/F module (MG30)• BCD / GO / NO GO output• Expansion module (Sequential lineup)

MG10-P1 : sink type output (–com)MG10-P2 : source type output (+com)

MG30-B1 : BCD sink type output (–com)MG30-B2 : BCD source type output (+com)

MG20-DK : DK series gaugesMG20-DG : DG**B and DL**B/BR series gaugesMG20-DT : DT series gauges

Unit : mm/inch

MG10-P1/P2

4.35/0.1735.65/1.40

33.1/1.3

64.5/2.54

64/2.52

108.5

/4.2

7

105/4

.13

99/3

.9

MG30-B1/B2

24.5/0.96

20.5/0.81

64.5/2.54

64/2.52

105.5

/4.1

5

99/3

.9

MG20-DT/DG/DK

4.35/0.17

23/0.91

20.5/0.81

64.5/2.54

64/2.52

108.5

/4.2

7

105/4

.13

99/3

.9

MG20-DK

10 11