Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Digital gaugeDK Series
Intelligent network systemMG40 Series
Multi point measuring unitMG10/20/30 Series
DK
MG&
SERIES
SERIES
DIGITAL GAUGE
Network interface
The contents of this literature are as of Jul. 2011This catalog is printed with soy ink.MGS-DKMG-1107-EN-C
http://www.mgscale.com
Shinagawa Intercity Tower A-18F, 2-15-1, Konan, Minato-ku, Tokyo 108-6018, JAPAN
Magnescale Co., Ltd.
HeadquartersTokyo OfficeNagoya OfficeOsaka OfficeInternational Sales DepartmentMagnescale Americas Inc. Magnescale Europe GmbH
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan2-35-16, Meieki, Nakamura-ku, Nagoya Aichi, 450-0002, JAPAN2-14-6, Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan5740 Warland Drive, Cypress, CA 90630, USAAntoniusstrasse 14, 73249 Wernau, Germany
TEL.+81 (0)463-92-1011TEL.+81 (0)463-92-7972TEL.+81 (0)52-587-1823TEL.+81 (0)6-6305-3101TEL.+81 (0)463-92-7971TEL.+1 (562) 594-5060TEL.+49 (0) 7153 934 291
FAX.+81 (0)463-92-1012FAX.+81 (0)463-92-7978FAX.+81 (0)52-587-1848FAX.+81 (0)6-6304-6586FAX.+81 (0)463-92-7978FAX.+1 (562) 594-5061FAX.+49(0) 7153 934 299
E-mail: [email protected]: [email protected]: [email protected]: [email protected]: [email protected]: [email protected]
:::::::
DK805AFLR/DK805BFLRDK805AFLR5/DK805BLFR5
DK805ALR/DK805BLRDK805ALR5/DK805BLR5
DK10
DK25
DK50
DK100
DK155/DK205DK155 shown
DK802
DK812
【NEW】DK830S
SERIES
DIGITAL GAUGE
2 3
Achieved over 20 million strokesin current testing
(DK830SR, DK830SLR)
Ball spindle bearing design reduces the affect of side loadon accuracy and durability
(DK830S series)
Slim and compact design withhigh performance
■Measurement range : 2 - 205 mm
■Accuracy : 1µm to 1.5µm (DK800 Series)
■Maximum resolution : 0.1µm, 0.5µm
■Maximum response speed:
80m/min. (at Max. resolution of 0.1µm)
250m/min.(at Max. resolution of 0.5µm)
■Built-in reference point
■Highly resistant against water and oil,
and excellent durability
■Available in spring push
The DK Series digital gauge with its slim and
compact design offers exceptional
performance of 0.1um resolution and
80m/minute response speed. Magnescale
magnetic technology, along with the use of
stainless steel components, allows the gauge
to perform with accuracy and durability even
under the harshest environments.
Long stroke mm30
High resolution μm
High response speed m/min800.1
Wide measurement range 2 to 205 mmAll measurements can be realized by wide range lineup
SERIES
Network interface
4 5
Ethernet or CC-Link models available
MG42MG41-NC
MG43
PLC
CC-LINK
MG42MG41-NE
MG43
Ethernet
FA computer
MG43
MG41-NE / MG41-NC / MG42-4MG10 / 20 / 30
BCD
RS-232C
Standard function: RS232C
PLC
PC
MG10 / 20 / 30
■The MG40 series, with its standard Ethernet interface, enables you to process and store remote data via 100Mbit/sec high speed data communication.
■Utilizing a single MG41 hub, up to 100 channels can be easily connected via one network cable.
■Ethernet and CC-Link interfaces eliminate the need for BCD or RS-232C wiring connections.
■In the event of a communication error, the system automatically aquires the correct positional information.
■Bi-directional serial digital communication allows for a higher response speed.
■DIN rail compatible (35mm)
The MG40 series intelligent network measurment system enables high-speed communication, multi-channel measurement and data
management. The MG40 series communicates with the DK series of gauges via a true digital communication protocol and does not rely upon
analog or AB phase outputs. Miscounts caused by external noise are eliminated and the system instantly recovers from communication errors.
■Up to 16 expansion modules can be connected to each MG10 main module
■Maximum 64 channels possible by link connection
■Available input resolutions of 0.1um, 0.5um, 1um, 5um, or 10um
■Standard RS-232C interface, BCD output also available
■DC12V - 24V operating voltage
■Din rail compatible (35 mm)
This modular measurement system is applicable to multi-channel measurement via RS232C or BCD
communication. The MG10 series allows multi-channel input to a PC or PLC through one main hub
reducing wiring and increasing efficiency.
Intelligent Network system Modular Measurement Unit
The MG40 series is an intelligent networkinterface system designed for highlyefficient multi-channel measurement For multi-channel measurment
Wide measurement range from 2 mm to 205 mmallows for a broad range of applications
Vacuum suction (DK802ALR / DK802ALR5 / DK802BLR / DK802BLR5)
100 m/s2
1000 m/s2
IP66 (not including interpolation box and connectors)
0˚C to 50˚C/32˚F to 122˚F
–20˚C to 60˚C/–4˚C to 140˚C
DC +5 V ±5%
1 W
2.5 m/8.2'
Approx. 20 g/0.7 oz
+P M4x5 screw (2pcs.). Installation spacer, Instruction Manual, Supplement
22 m/72.2' max.
A/B/REF differential TTL output (compliant with EIA-422)
2 mm (0.08")
One location (at 1 mm/0.04" position of spindle movement)
ModelDK802BR, DK802BLR DK802AR5, DK802ALR5 DK802BR5, DK802BLR5
High resolution type General purpose type
DK802AR, DK802ALR
*1: The mass indicated is the total mass excluding the cable and interpolation box.
Output
Resolution
Measuring range
Accuracy (at 20˚C / 68˚F)
Measuring force (at 20˚C / 68˚F)
Reference point
Maximum response speed
Air driving
Vibration resistance (10 to 2000 Hz)
Impact resistance (11 ms)
Protective structure
Operating temperature
Storage temperature
Power supply voltage
Power consumption
Cable length
Diameter of stem
Mass*1
Feeler
Accessories
Output cable length(up to the electronic section)
0.1 µm
1 µm
0.5 µm
1.5 µm
Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Provided with a steel ball tip Mount screw M2.5
80 m/min 250 m/min 100 m/min42 m/min
ø8 / 0.31”dia.
Specifications
Downward: 0.45 ± 0.25 N Horizontal: 0.40 ± 0.25 N Upward: 0.35 ± 0.25 N
DK802
Vacuum suction (DK812AFLR / DK812AFLR5 / DK812BFLR / DK812BFLR5)
Pneumatic push type (DK812AVR / DK812AVR5 / DK812BVR / DK812BVR5)
100 m/s2
1000 m/s2
IP66 (not including interpolation box and connectors)
0˚C to 50˚C/32˚C F to 122˚F
–20˚C to 60˚C/–4˚CF to 140˚F
DC +5 V ±5%
1 W
2.5 m/8.2'
φ9.5/0.37” dia. (Flange type), φ8/0.31” dia. (others)
Approx. 30 g/1.06 oz
+P M4x5 screw (2pcs.). Installation spacer, Instruction Manual, Supplement
22 m/72.2' max.
A/B/ phase voltage-differential line driver output (compliant with EIA-422)
12 mm (0.47")
One location (at 1 mm/0.04" position of spindle movement)
Model DK812BR, DK812BLR, DK812BFR,DK812BFLR, DK812BVR
DK812AR5, DK812ALR5, DK812AFR5,DK812AFLR5, DK812AVR5
DK812BR5, DK812BLR5, DK812BFR5,DK812BFLR5, DK812BVR5
High-resolution models General-purpose resolution models
DK812AR, DK812ALR, DK812AFR,DK812AFLR, DK812AVR
*1 : Please refer to P10 DK 802 A/B about the extension cable (Option). *2 : The mass indicated is the total mass excluding the cable and interpolation box.
Output
Resolution
Measuring range
Accuracy (at 20˚C / 68˚F)
Reference point
Maximum response speed
Vibration resistance (10 to 2000 Hz)
Impact resistance (11 ms)
Protective structure
Operating temperature
Storage temperature
Power supply voltage
Power consumption
Cable length*2
Diameter of stem
Mass*1
Feeler
Accessories
Output cable length(up to the electronic section)
Measuring force(at 20˚C / 68˚F)
0.1 µm
1 µm
0.5 µm
1.5 µm
Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Provided with a steel ball tip Mount screw M2.5
80 m/min 250 m/min 100 m/min42 m/min
Specifications
Downward : 0.6 ± 0.3 NHorizontal : 0.5 ± 0.3 N
Upward : 0.4 ± 0.3 NAir pressure of 0.03Mpa : 1N or less in all directions
Air pressure of 0.04Mpa : 1.7N or less in all directions
Air driving
DK812
6 7
DK830SVR
ø13.
6/ø0
.54
ø17.
9/ø0
.70
ø24.
3/ø0
.96
ø34.
1/ø1
.34
ø4ø8ø12 8.6 45.7
154/6.06
Adoption tube ø4/ø0.16ø4.8/ø0.19 ø8/ø0.31
10.2/0.40138.4/5.45
DK830SR
ø4.8
/ø0
.19
ø8.2
/ø0
.32
17/0.67
(28/
1.10
)
110/4.33
t=15.5(101/3.98)300/11.81
Cable length 2400/78.74
2-ø4.5/Mountin
g hole
ø5.8
/ø0.
23
ø4.8
/ø0.
19
ø4/ø
0.16
ø8/ø
0.31
ø12/
ø0.4
7
39.6/1.56 45.7/1.80
195.2/
DK830SLR
ø13.
6/ø0
.54
ø17.
9/ø0
.70
ø24.
3/ø0
.96
ø34.
1/ø1
.34ø4
/ø0.
16ø8
/ø0.
31ø1
2/ø0
.47
39.6/1.56 45.7/1.80
185/7a.2888.4 39 26
ø4.8/ø0.19
10.2/0.40
169.4/6.67
【NEW】DK830
Measuring rangeResolutionAcucracy(at 20˚C / 68°F)
Measuring force
Operating tempertureStrage tempertureMaximum response speedRefence response speedAir drivingReference point positionProtective design grade (Note1)Vibration resistanceImpact resistanceCable lngthDiameter of stemFeelerPower supply voltagePower consumptionMass (Note3)OutputGaranteed number of strokesOutput cable length(up to the electronic section)Accessiries
Model DK830SR DK830SLR
IP53/IP67 (Note2)IP53
DK830SVR
1.7 μm
Pneumatic push type
Approx. 80 g
10 million or more
Air presser 0.07 Mpa 1.9 N or less for all diectionAir presser 0.09 Mpa 2.6 N or less for all diection
Specifications
Note1: Except interpolation box and connector Note2: Bellows set(Option accessory) Note3: Except cable and interpolation box Note4: According to the evaluation method of Magnescale.
30 mm0.1 μm
0 to 50˚C-20 to 60˚C80 m/min80 m/min
One point at 1mm spindle move
10 to 2kHz 100 m/s2
1000 m/s2 11 msApprox. 2.4 m
φ8Provided with a carbide tip, Mounting screw M2.5
DC 5 V±5 %1 W
A/B/REF voltage-differential line driver output (compliant with EIA-422)
22 m MAXSpanner, Instruction manual, Supplimanet, +P M4x5 screw(2 pcs.)
1.3 μmUpward: 0.5 ±0.35 N
Horizontal: 0.6 ±0.35 NDownward: 0.7 ±0.35 N
non
Approx. 70 g
20 million or more
3957.3 26
3988.4 26
DK812ALR/DK812ALR5/DK812BLR/DK812BLR5
ø10/
ø0.3
921
/0.8
3
ø9/ø0.3529.7/1.17 18/0.71
87/3.43
97/3.82
105/4.13
6
DK812AVR/DK812AVR5/DK812BVR/DK812BVR5
ø10/
ø0.3
9
21/0
.83
18/0.71 ø9/ø0.35170.67
(94.4/3.72)
105/4.13
(107.1/4.22)
92.3/3.68
DK812AFLR/DK812AFLR5/DK812BFLR/DK812BFLR5
8/0.315.8/0.23 4.2/0.17
ø12/
ø0.4
7M9
ø10/
ø0.3
9
21/0
.83
ø9/ø0.35
29.7/1.17
105/4.13
97/3.82
87.5
6
DK812AFR/DK812AFR5/DK812BFR/DK812BFR5
5.8/0.238/0.31
ø12/
ø0.4
7M9
4.2/0.17
105/4.13
29.7/1.17
6
DK812AR/DK812AR5/DK812BR/DK812BR5
Cable length 2000/78.74
Cable length 300/11.81 (101/3.98)
ø4.8
/ø0.
19
105/4.13
ø80 −0.
00,9
35.5/1.4
29.7/1.17 18/0.71
6
(28)
92-ø4.2
ø8.5
Thickness 15.2
-0.0
004
0-0
.009
0
/ø0.
37
ø9.5
ø9.5
/ø0.
37(S
tem
)
DK802AR/DK802AR5/DK802BR/DK802BR5
64.2/2.53
8.6/0.3412.2/0.48
DK802ALR/DK802ALR5/DK802BLR/DK802BLR5
56.2/2.21
ø9/ø0.35
21/0
.83
ø10/
ø0.3
9
46.2/1.82
8.6/0.3412.2/0.48
64.2/2.53
Option : Extension cable
13/0
.51
Cable length 1,3,5,10m (39.37"/118.11"/196.85"/393.70")
ø11.
8/ø0
.46
ø10/
ø0.3
9
41.5/1.63
13/0.51 13.6/0.54
14/0.555.5/0.225.5/0.22 30.5/1.2
49.5/1.9535.5/1.4
6.2/0.24 24.3/0.964.8/0.16 13
.6/0
.54
(CK-T12:1m/3.3’, CK-T13:3m/9.8’, CK-T14:5m/16’, CK-T15:10m/32.8’)
13.6
/0.5
4 Cable length 1,3,5,10m
50/1.9741.5/1.63
55.5/2.19
Option : Extension cable(CE22-01:1m/3.3’, CE22-03:3m/9.8’, CE22-05:5m/16’, CE22-10:10m/32.8’)
+VccSignal Cable color
RedWhiteBlue
YellowOrange
GrayGreenViolet
–
–
–
0VAABBZZ
(39.37"/118.11"/196.85"/393.70")
Unit : mm/inch
Unit : mm/inch
Model DK805AFR5, DK805AFLR5,DK805AR5, DK805ALR5
DK805BFR5, DK805BFLR5,DK805BR5, DK805BLR5
DK805BFR, DK805BFLR,DK805BR, DK805BLR
DK805AFR, DK805AFLR,DK805AR, DK805ALR
Output
Resolution
Measuring range
Accuracy (at 20˚C/68˚F)
Measuring force(at 20˚C/68˚F)Reference point
Maximum response speed
Air driving
Shock resistance (11 ms)
Protective structure
Operating temperature
Storage temperature
Power supply voltage
Power consumption
Cable length*1
Diameter of stem
Mass*2
Feeler
AccessoriesOutput cable length(up to the electronic section)
Vibration resistance(10 to 2000 Hz)
A/B/ phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference.
Vacuum suction ( DK805AFLR / DK805AFLR5 / DK805BFLR / DK805BFLR5 / DK805ALR / DK805BLR / DK805ALR5 / DK805BLR5 )
100 m/s2
1000 m/s2
IP66 (not including interpolation box and connectors)
0˚C to 50˚C/32˚F to 122˚F
-20˚C to 60˚C/-4˚F to 140˚F
DC +5 V ±5%
1 W
2.5 m/8.2'
ø9.50 /0.37" dia.
Approx. 30 g/1.06 oz
Installation spacer, Instruction Manual, Supplement
22 m/72.2' max.
5 mm (0.19")
Downward: 0.45 ± 0.25 N Horizontal: 0.40 ± 0.25 N Upward: 0.35 ± 0.25 NOne location (at 1 mm/0.04" position of spindle movement)
0.1 µm
1 µm
0.5 µm
1.5 µm
Provided with a carbide ball tip (DZ-123) Mount screw M2.5 Provided with a steel ball tip Mount screw M2.5
80 m/min 42 m/min 250 m/min 100 m/min
High-resolution models General-purpose resolution model
*1 : Please refer to P10 DK 802 A/B about the extension cable (Option).*2 : The mass indicated is the total mass excluding the cable and interpolation box.
0-0.009
0-0.0004
Specifications
DK805
DK805AFR/DK805BFRDK805AFR5/DK805BFR5
DK805ALR/DK805BLRDK805ALR5/DK805BLR5
DK805AR/DK805BRDK805AR5/DK805BR5
DK805AFLR/DK805BFLRDK805AFLR5/DK805BFLR5
79.6/31.3
21.2/0.83
0 −0.0
09/
0 −0.0
04ø8
/0.3
1
0.34/8.6
21.2/0.83
71.6/31.3
0 −0.0
09/
0 −0.0
04
ø95
ø0.3
7
4/0.265.3/0.218.7/0.34
M9xP0.5
4-ø2.1 deep2.5/ø0.08 deep0.1
ø12/
0.47
79.6/31.3
71.6/2.82
21.2/0.83
61.6/2.43
8.7/0.345.3/0.21 4/0.16
0 −0.0
09/
0 −0.0
04
ø9.5
ø0.3
7
M9xP0.5
4-ø2.1 deep2.5/ø0.08 deep0.1
ø12/
0.47
21/0
.83
ø9/ø0.35
ø10/
ø0.3
9
21.2/0.83 0.34/8.6
0 −0.0
09/
0 −0.0
04ø8
/0.3
1
21/0
.83ø1
0/ø0
.39
79.6/3.13
61.6/2.43
71.6/2.82
ø9/ø035
Unit : mm/inch
Unit : mm/inch
8 9
DK50/100/155/205
Model
Output
Resolution*1
Measuring range
Accuracy (at 20˚C)
Specifications
Upward
Horizontal
Downward
Measuringforce(at 20˚C)
Reference point
Maximum response speed
Vibration resistance (10 to 2000 Hz)
Impact resistance (11 ms)
Protective structure
Operating temperature
Storage temperature
Power supply voltage
Power consumption
Cable length*2
Diameter of stem
Mass*3
Feeler
Output cable length
Guaranteed number of Strokes
Accessories
DK50NR5 DK50PR5 DK100NR5 DK100PR5 DK205DK155
50 mm
2 µm
100 mm
4 µm
155 mm
5 µm
205 mm
6 µm
—
0.9 ± 0.4 N
1.3 ± 0.5 N4.9 N or less
—
1.8 ± 0.65 N
2.7 ± 0.55 N4.9 N or less
−
−
Approx. 2.2N (by mass of spindle)
−
−
Approx. 2.2N (by mass of spindle)
A/B/ phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference.
0.5 µm
One location (at 1 mm position of spindle movement)
250 m/min
150 m/s2
1500 m/s2
0˚C to 50˚C
-20˚C to 60˚C
DC +5 V ±5%
1 W or less
Approx. 2.5 m
ø 20 mm0 -0.013
22 m max.
Minimum 5 million cycles without shock
+P M4x5 screw (2 pcs.), Instruction Manual
IP50 IP50 IP64IP64
Approx. 360 g Approx. 1100 g Approx. 1300 gApprox. 630 g
Provided with a carbide ball tip DZ-122 (Mount screw M2.5) Magnetic substanceProvided with a carbide ball tip DZ-121 (Mount screw M2.5)
*1 : The resolution setting needs to be made when connecting to the LT30 series, MG series, and LY70 series. For details, please refer to the respective instruction manual.*2 : Please refer to P10 DK 802 A/B about the extension cable (Option). *3 : The mass indicated is the total mass excluding the cable and interpolation box.
0 -0.05ø 32 mm
0 0 0-0.0
02/ø
1.26
-0.0
5 0
ø32
-0.0
02/ø
1.26
-0.0
5ø3
2
(20/0.79)
ø5.8
/ø0.
23
ø22
/ø0.
87
9/0.35
ø8 /ø0.
31
28/1.1
(ste
m)
416/16.38 ~ 571/22.48
407/16.02
DK155PR5
DK205PR5
-0.002 0/ø1.26-0.05 0ø32
(20/0.79)
ø5.8
/ø0.
2328/1.1
-0.002 0/ø1.26-0.05 0ø32
(stem)
ø22
/ø0.
87
9/0.35
ø8 /ø0.
31
516/20.31 ~ 721/28.39
507/19.96
-0.0
040
-0.0
13 0
-0.0
005
0
-0.10
12/0.47 (20/0.79)
ø5.8
/ø0.
23
ø20
/ø0.
79(s
tem
)
ø0.9
8ø2
5
ø8 /ø0.
31
(102/4.02)2.5/0.1 38.5/1.52
329/12.95443.5/17.46
DK100NR5/PR5DK50NR5/PR5
ø6 /ø0.
24 -0.0
13 0
ø20
-0.0
005
0/ø
0.79
(ste
m)
-0.0
03 0
.000
8/ø
0.78
(ste
m)
-0.0
7-0
.02
ø20
12/0.47 51/2.01 44/1.73223/8.78
286/11.26 (20/0.79)
ø5.8
/ø0.
23
Model
*1 : The resolution setting needs to be made when connecting to the LT30 series, MG series, and LY70 series. For details, please refer to the respective instruction manual.*2 : Please refer to P10 DK 802 A/B about the extension cable (Option). *3 : The mass indicated is the total mass excluding the cable and interpolation box.
Output
Resolution*1
Measuring range
Accuracy (at 20˚C)
Specifications
DK10PLR5
ø5.8
/ø0.
23
102.5/4.04
12.3/0.48
ø22/ø0.87
79/3.1126.3/1.0352.7/2.07
-0.0
7-0
.02
ø20-0
.013
0ø2
0 -0.0
005
0/ø
0.79
-0.0
030.
0008
/ø0.
79
21.3/0.84
(ste
m)
12/0.47
(11.5/0.45)
ø6/ø
0.24
37/1
.46
69.5
/2.7
4
(20/
0.79
)
*Please refer to p54 forthe details of the screw.
DK25NLR5/PLR5
12/0.47
160/6.3
(26.5/1.04)121.5/4.78
95.2/3.75 26.3/1.0433.8/1.33
ø6/ø
0.24
-0.0
130
ø20 -0
.000
50
/ø0.
79(s
tem
)
-0.0
7-0
.02
ø20 -0
.003
0.00
08/ø
0.79
12.3/0.48
ø22/ø0.87
Cable length2500/98.42
37/1
.46
69.5
/2.7
4
(20/
0.79
)
-0.0
130 -0
.000
50 -0.0
7-0
.02
-0.0
030.
0008
ø20
/ø0.
79(s
tem
)
ø20
/ø0.
79 Cable length 2500/98.42
ø6/ø
0.34
12/0.47
(11.5/0.45)21.3/0.84
98.5/3.88122/4.81
(20/0.79)
ø5.8
/ø0.
23
DK10NR5/PR5 DK25NR5/PR5
(20/0.79)
Cable length 2500/98.42
ø5.8
/ø0.
23
-0.0
130
ø20 -0
.000
50
/ø0.
79(s
tem
) -0.0
7-0
.02
ø20 -0
.003
0.00
08/ø
0.79
ø6/ø
0.24
12/0.47 (26.5/1.04)33.8/1.33
141/5.55179.5/7.07
DK10/25
Upward
Horizontal
Downward
Measuringforce(at 20˚C)
Impact resistance (11 ms)
Protective structure
Operating temperature
Storage temperature
Power supply voltage
Power consumption
Cable length*2
Diameter of stem
Mass*3
Feeler
Output cable length
Guaranteed number of Strokes
Accessories
Reference point
Maximum response speed
Vibration resistance (10 to 2000 Hz)
0.3 ± 0.25 N
0.6 ± 0.3 N
0.8 ± 0.35 N4.9 N or less
150 m/s2
1500 m/s2
10 mm 25 mm
Approx. 230 g Approx. 300 g
4.9 N or less 4.9 N or less
IP50
DK10NR5
0.4 ± 0.3 N
0.7 ± 0.35 N
1 ± 0.4 N
IP50
DK25NR5
0.4 ± 0.3 N
0.7 ± 0.35 N
1 ± 0.4 N
IP50IP64 IP64 IP64
DK25NLR5 DK25PLR5DK25PR5DK10PLR5DK10PR5A/B/ phase voltage-differential line driver output (compliant with EIA-422) *Please see P17 Output Signal Phase Difference.
0.5 µm
2 µm
One location (at 1 mm position of spindle movement)
250 m/min
0˚C to 50˚C
-20˚C to 60˚C
DC +5 V ±5%
1 W
Approx. 2.5 m
ø 20 mm0 -0.013
Provided with a carbide ball tip DZ-122 (Mount screw M2.5)
22 m max.
Minimum 5 million cycles without shock
+P M4x5 screw (2 pcs.), Instruction Manual
DK Series measuring unit output signals
A
B
REF
The signals output from this measuring unit are A/B quadrature signal, Z signal in the form of voltage-differential line driver output compliant with EIA-422.
Before using, check that the minimum input phase difference of the control device connected to this measuring unit or the counter is smaller than 50 ns for the DK800A (A signal cycle: 200 ns, 5 MHz) or smaller than 100 ns for the DK800B (A cycle: 400 ns, 2.5 MHz). *The minimum phase difference can be modified under special specifications.
Before using, check that the minimum input phase difference of the control device connected to this measuring unit or the counter is smaller than 50 ns for-DK 10~110 series (A signal cycle: 200 ns, 5 MHz).*The minimum phase difference can be modified under special specifications.
The reference point signal is synchronized with A and B signal.
A
B
50 ns
200 ns (5 MHz)
DK800A output signals at maximumresponse speed (at approx. 80 m/min)
A
B
100 ns
400 ns (2.5 MHz)
DK800B output signals at maximumresponse speed (at approx. 42 m/min)
A
B
50 ns
200 ns (5 MHz)
DK10/25/100/110/155/205Output signals at maximum response speed (at approx. 42 m/min)
DK800 Series
The travel amount of the measuring unit is detected every 50 ns for the DK800A and every 100 ns for the DK800B, and the phase difference proportional to the amount traveled is output. The phase difference changes in integer multiples of 50 ns or 100 ns. Also, the minimum phase difference for the A and B is 50 ns for the DK800A and 100 ns for the DK800B.
A
B
Integer multiple of 50 ns or 100 ns
In maximum standard specifications, the minimum phase difference is fixed at 50 ns for the DK800A and 100 ns for the DK800B, but the minimum phase differences in the table below are available as special specifications.
100 ns DK800B standard product
50 ns DK800A standard product
300 ns Special specifications
500 ns
400 ns
200 ns
1.2 µs
2 µs
2.5 MHz
5 MHz
833 kHz
500 kHz
42 m/min
80 m/min
14 m/min
8.4 m/min
100 m/min
250 m/min
33 m/min
20 m/min Special specifications
A/B minimumphasedifference
Maximum response speed
Resolution 0.1 µm Resolution 0.5 µmRemarks
Counterallowablefrequency
A signalcycle
The travel amount of the measuring unit is detected every 50 ns, and the phase difference proportional to the amount traveled is output. The phase difference changes in integer multiples of 50 ns. Also, the minimum phase difference for the A and B is 50 ns.
Output Signal Phase Difference
A
B
Integer multiple of 50 ns
DK10/25/100/110/155/205
In the standard specifications, the minimum phase difference is fixed at 50 ns, but the minimum phase differences in the table below are available as special specifications.
100 ns
50 ns
300 ns
500 ns
A/B minimumphasedifference
100 m/min
250 m/min
33 m/min
20 m/min
Maximum response speedResolution 0.5 µm
Special specifications
Standard product
Special specifications
Special specifications
Remarks
2.5 MHz
5 MHz
833 kHz
500 kHz
Counterallowablefrequency
400 ns
200 ns
1.2 µs
2 µs
A signalcycle
Unit : mm/inch
Unit : mm/inch
If the response speed is exceeded, the A/B output from this measuring unit changes to Hi impeadance for about 400 ms to serve as an alarm.
Output Signal Alarm
Alarm section A/B is Hi impeadance
Receiver
DK10/25/100/155/205/110
(*If extending the cable, the supply voltage is +5 V±5%.) *Use the CE22 series extension cables for bare wires (optional accessories).
20 m or less
Line driver
Output: phase A/B/
*+V
0V
+V
AM26C32
DS34C87
0V
Line driver Line receiver AM26C32 or equivalentSIG
120
SIG*SIG
A
B
DK830S series model nameAvailable specification by option
DK830SR□□DK830SLR□□DK830SVR□□ 100 ns
50 ns(Standard)
300 ns
500 ns
A/B minimumphasedifference
Mark
-
B
C
D
0.5 µm
0.1 µm(Standard)
1 µm
Resolution Mark
-
05
10
A/B minimun phase diffence
A/B frequncy
Resolution
0.1 µm
0.5 µm
1 µm
Maximum response speed (m/min)
5.0 MHz
50 ns
80(Standard)
2.5 MHz
100 ns
42
100
200
0.8 MHz
300 ns
14
33
66
0.5 MHz
500 ns
8.4
20
40
Connectable measuring units
Connection cable length
Resolution
Measuring unit data import capacity
Comparator function
Reset function
Preset function
Datum point setting function
Reference point function
Master calibration function
Measuring unit product information
Item Description RemarksConditions
Measuring unit resolution(input resolution)
Comparator setting values
No. of setting value groups
Peak-hold function
Output data
Ethernet
Supply voltage
Command/setting enabledor disabled for eachcommunication line
Power consumption
Operating temperature and humidity range
Storage temperature and humidity range
Mass
Command
Data output
DC 12 to 24 V (11 to 26.4 V)
System total: Max. current 4 A
When the maximum current is exceeded, the connection can be enabled by providing a power supply to the MG42 hub units that come later in the connection.
<Details of power consumption for each unit> MG41 main unit : 4 W , MG42 hub unit : 1 W/unit , Measuring unit supply : 1 W/unit
0 to +50 ˚C (no condensation)
-10 to +60 ˚C (20 to 90 % RH)
MG41 : 300 g , MG42 : 250 g
Settings
Ethernet
Available
Reset function
Preset function
Datum point setting function
Reference point function
Master calibration function
Comparator value setting
Comparator group number setting
Start
Pause
Latch
Current value/Peak value (All axes)
Current value/Peak value (each unit)
Comparator result
Alarm (Communication/Measuring unit)
Soft ware version
Measuring unit product information
Input resolution
Display and output resolution
Axis addition
Comparator mode (2, 4, 8, or 16 values in 1 group)
CC−Link
Available
N/A
Available
0.1μm
-
0.5μm
0.5μm
1μm
1μm
5μm
5μm
2 values
16 groups
4 values
8 groups
8 values
4 groups
16 values
2 groups
10μm
10μm
Terminal input
Note the connectionconditions.
Entire system
MG41 main unit
MG42 hub unit
0.1μm
0.5μm
10 Mbps data transfer
Single axis
1 to 100 units (Connection disabled aft er connection of 101st unit.)
DK800A/DK 800B series, DK10, DK25, DK50, DK100, DK110, DK155, DK205
Settable output data resolution and display resolution
Maximum 10,000 data/s (when 100 axes are connected)
Calculation of maximum value, minimum value, and peak-to-peak value for each axis (including pause, latch, and start functions)
Peak value is not updated during pause.
Output and display data are not updated during latching (internal data is updated)
Recalculation of peak value is started by start function.
Current value, maximum value, minimum value, and peak-to-peak value for each axis
Data for each axis (single axis, addition/subtraction axis) is compared and measured, and the comparator results are output.(Comparator during latch is also latched.)
Current value for each axis is reset (by command).
Value is preset to the current value of each axis (by command).
Datum point of each axis can be set (by command).
Reference point can be used to relocate the datum point of each axis (by command).
Reference point can be used to perform master calibration for each axis (by command).
The product information of the connected measuring unit can be acquired.
0 to 4 axis
Between MG41 main unit and MG42 hub unit, between MG42 hubunit and MG42 hub unit: 0.5 m, 1 m, 2 m, 5 m, 10 m
Total cable length from MG41 main unit: Maximum 30 m(Maximum current: 4 A or less)
100Base-T (compliant with IEEE 802.3) 100 Mbps/10 Mbps (Auto-negotiation)Command input, data output, and parameter setting are possible.
Up to 24 connected MG42 hub units
The data for one axis is counted as one data.
Addition/subtraction axis cannot be used.
When master calibration function is not used
Use a power supply with a current that is4 A or higher.(Recommended: +24 V)(for every six MG42 hub units)
No. of connectablemeasuring units
Single axis calculation of an addition/subtraction axis isnot possible(for preventing inconsistencies in calculation).
Addition and subtraction Current value, maximum value, minimum value, and peak-to-peak value for the two-axis addition/subtraction axis
When master calibration function is not used
MG40 MG10/20/30 SERIESSpecifications
Specifications
Unit:mmUnit:mm
Main unitMG41-NC(CC-Link)
155
43
155
43
Main unitMG41-NE(Ethernet)
67.4 67.458
4032
.532
.5
4-M3 depth 8 or less
192.812.8
5525
25
2-M2depth 8 or less
2-M2depth 8 or less
7.3
105
55 92.6
71.7
16.5
6.2
16.8
6.2
7.3
8.5
12.8
25
26.9 4.3
258.
5
Display unitMG43
Item DescriptionCompatible main units
Compatible hub units
Compatible measuring units
Main functions
Communication protocol
Screen display
MG41-NE/MG41-NC
Hub units compatible with the main unit
Measuring units compatible with the main unit or hub unit
Measure Monitor, Setting Monitor, System Monitor
MG40 original protocol on TCP/IP
480 x 272 pixels, 4.3-inch TFT LCD with backlight
Item DescriptionNetwork interface
Power consumption
Power supply
Operating temperature range
Storage temperature and humidity range
Mass
100Base-TX / 10Base-T (compliant with IEEE802.3) Auto-negotiation
DC12~24V(11~26.4V)
4W
0 to +40°C (no condensation)
-10~+60˚C(20~90%RH)
Approx.500g
Hub unitMG42
155
43 69
�MG41、42 common
186 +10
93.5
+1 0
103
30
4-ø4.5
<MG43 Mounting the display unit form the panel front>
Model name
Power source
Communication
Linkage function
I / O
Connectable modules
Supply voltagePower consumptionInrush current (10ms)Power supply protectionCommunication I/FBaud rate settingData lengthStop bitParityDelimiterMaximum number of linkagesMaximum length of linking cable
DC12-24V(11-26.4V)Min. startup time: 100ms or less2.0W + total power consumption for connected modules*1
10A or less (when maximum number of modules are connected)Fuse (5A fuse is built in.)
RS-232C (EIA-232C or equivalent)2400 / 9600 / 19200 / 38400 bps (set with DIP switch)
7 / 8 bit (set with DIP switch)1 / 2 bit (set with DIP switch)
none / ODD / EVEN (set with DIP switch)CR / CR+LF (set with DIP switch)16 (total of counter modules: 64)
10m
Photo coupler insulation, external power: DC5 – 24V
Photo coupler insulation, external power: DC5 – 24Vreset, pause, start, latching, and data out trigger to whole channels
integrated alarmMG20-DK, MG20-DG and MG-20DT (available for mixed use, up to 16 modules) *1
MG30-B1,MG30-B2
Input formatsource input (+COM)
sink type (–COM)
sink input (–COM)
source type (+COM)
MG10-P1 MG10-P2
Output format
Main module
Input signalOutput signalCounter modulesInterface modules
Display unit MG43
*1 : Total power of modules connected to MG10 should not be over 54W (12VDC Input) or 108 W (24VDC Input).
*2 : Set the resolution value of the connected gauge. *3 : MG20-DG work only connect to DL**BR series
Model namePower consumption
Corresponding gauge
Maximum response speedReference point *3
MG20-DK MG20-DG MG20-DT1W + power consumption for connected gauge
DK series (A/B quadrature input)10 / 5 / 1 / 0.5 / 0.1µm
1.4W (connected to DG-B) / 0.5W (connected to DL-B)DG**B series, DL**B/DL**BR series
10 / 5 / 0.5µmset with DIP switch
S-ALM LED activates by excess speed/acceleration of measuring unit. C-ALM LED activates by excess speed of the internal circuit of counter.Alarm display is cancelled by reset command from MG10 or with the reset button of main unit.
0.8WDT series
5µm (DT12/32) 1µm (DT512)
100m / min–
Measuringunit input
Others Alarm
Subject to the specification of the connected gauge
Allowable resolution setting *2
REF-LED (reference point loaded) shows on the display after the reference point is detected. Set “0” or preset value on the counter when the reference point is detected.
Counter module
Model name
I/O
Output setting
source input (+com)
sink type (–com)
sink input (–com)
source type (+com)
1w
Photo coupler insulation, external power: DC5 – 24V
Photo coupler insulation, external power: DC5 – 24V DRQ / channel address / measuring mode shifting / comparator shifting / reset / start / posing / reference point loaded
BCD data (6 digits) / READY / code / GO/NO GO output / alarm / reference point loadedtimer (1~128ms) / OUT / OR / polarity (set with internal DIP switch)
Input format
Output format
Input signalOutput signal
All models Operating temperature Storage temperature
0~+50˚C (No condensation) –10~+60˚C (20~90%RH)
Interface module
Power consumption
MG30-B1 MG30-B2
“MG”Multi Interface unit operates with a variety of modules.
Counter module (MG20)• Digital gauge input• Resolution setting
Main module (MG10)• Power supply• RS-232C Connection• Connection with Counter module, I/F module
I/F module (MG30)• BCD / GO / NO GO output• Expansion module (Sequential lineup)
MG10-P1 : sink type output (–com)MG10-P2 : source type output (+com)
MG30-B1 : BCD sink type output (–com)MG30-B2 : BCD source type output (+com)
MG20-DK : DK series gaugesMG20-DG : DG**B and DL**B/BR series gaugesMG20-DT : DT series gauges
Unit : mm/inch
MG10-P1/P2
4.35/0.1735.65/1.40
33.1/1.3
64.5/2.54
64/2.52
108.5
/4.2
7
105/4
.13
99/3
.9
MG30-B1/B2
24.5/0.96
20.5/0.81
64.5/2.54
64/2.52
105.5
/4.1
5
99/3
.9
MG20-DT/DG/DK
4.35/0.17
23/0.91
20.5/0.81
64.5/2.54
64/2.52
108.5
/4.2
7
105/4
.13
99/3
.9
MG20-DK
10 11