Page 1: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control AdapterData Sheet

Page 2: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without noticeii | Digital Control Adapter Data Sheet

TABLE OF CONTENTS

1 Description and Key Features

2 Ordering Information

3 Mechanical Drawing and Wiring Specifications

4 Lutron® EcoSystem Protocol

5 DMX512-A-RDM Protocol

6 Wiring Diagrams

   

UL  Recognized  Component  Dry  or  Damp  Locations  

Class  2   Input  

   

 

Designed in California, USAAssembled in USA   Designed  in  California,  USA  Assembled  in  USA  

 

 

UL Recognized ComponentDry or Damp Locations Class 2 Input

   

UL  Recognized  Component  Dry  or  Damp  Locations  

Class  2  Input    

Lumenetix Inc. • 4742 Scotts Valley Dr. • Scotts Valley, CA 95066Lumenetix, araya5, Dynamic Dimming and SceneSet are registered trademarks of Lumenetix, Inc. © Lumenetix, Inc. 2019.

877.805.7284 • www.lumenetix.com • [email protected]

Page 3: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice3 | Digital Control Adapter Data Sheet

DescriptionThe Digital Control Adapter (DCA) enables fixtures powered by araya

®5 LED modules to be controlled by standard lighting protocols.

The adapter converts standards-based lighting protocols to a digital link that connects to the araya5 modules.

The standards supported are:• EcoSystem by Lutron

®

• DMX512-A-RDM (including Bluetooth)

Key Features• 12V or 24V.

• Compatible with araya5 CTM1 color tuning modules, and DDM1 dynamic dimming modules.

• Enables Lutron EcoSystem and DMX512-A-RDM compatible product offerings.

• Each adapter is addressable.

• Controls continuous dimming from 100% - 1% in increments of 1%.

• Controls continuous color tuning from: – 1650-4000K — CTM1B, Bluetooth-integrated – 1650-8000K — CTM1C, Bluetooth-integrated

• Controls dimming from 3050K at full intensity to 1800K at 1% intensity: – DDM1B, Bluetooth-integrated – DDM1C, Bluetooth-integrated

• DMX adapter enables dimming, color tuning, hue and saturation features.

1 DESCRIPTION AND KEY FEATURES

Page 4: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice4 | Digital Control Adapter Data Sheet

General Specifications and Ordering CodesPower

Connector Type 2 position Molex Pico-SPOX

Wire Size 24 AWG

Operating Voltage 12V DC to 24V DC

Absolute Maximum Voltage 28V DC

Power Consumption 0.25 W

Reverse Voltage Protection 40V DC

ESD protection Special handling not required

Environment

Operating Temperature 0° C to 65° C

Location Type Dry

Lutron® EcoSystem Input (DCA-1A)* (DISCONTINUED - NO LONGER AVAILABLE)

Connector Type Refer to “Wiring Specifications” Section

Wire Size 16 AWG solid wire (EcoSystem input); 24 AWG stranded wire (Lux output)

Wiring Class EcoSystem Input: Class 1 or Class 2; LX Output: Class 2

Line Voltage Miswire Protection 277V AC (EcoSystem Input)

Ordering Codes DDM0 / DDM1 (1800 - 3050K): 45.020.008.04 (EAECOS1; one channel)

CTM0 / CTM1: 45.020.008.05 (EAECOS2; two channel)

DMX Input (DCA-1B)* (DISCONTINUED - NO LONGER AVAILABLE)

Connector Type Refer to “Wiring Specifications” Section

Wire Size 24 AWG stranded wire (DMX input and Lux output)

Wiring Class DMX Input: Class 1 or Class 2; LX Output: Class 2

Ordering Codes DDM0 / DDM1 (1800 - 3050K); CTM0 / CTM1 (1650 - 4000K): 45.020.008.02 (EADDB-40-R)

CTM0 (2700 - 6000K): 45.020.008.03 (EADDB-60-R)

Lutron®

EcoSystem Input (DCA-2)**

Connector Type Refer to “Wiring Specifications” Section

Wire Size 24 AWG

Wiring Class EcoSystem Input: Class 1 or Class 2; DMX Output: Class 2

Line Voltage Miswire Protection 277V AC (EcoSystem Input)

Ordering Codes DDM1B and DDM1C (Bluetooth-integrated): 80.005.001.02 (EAECOS1-G2; one channel)

CTM1B and CTM1C (Bluetooth-integrated): 80.005.002.02 (EAECOS2-G2; two channel)

*LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE).

**DMX Output is used with CTM 1B, CTM1C and DDM 1C.

2 ORDERING INFORMATION

Page 5: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice5 | Digital Control Adapter Data Sheet

Mechanical Drawing2X 4.83

.19

88.93.50

76.23.00

64.62.5

32.31.27

64.62.54

4.16

25.91.0

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFLUMENETIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUMENETIX IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

NEXT ASSY USED ON

APPLICATION

DIMENSIONS ARE IN MILLIMETERSTOLERANCES:ANGULAR: MACH 0.5ONE PLACE DECIMAL 0.5TWO PLACE DECIMAL 0.15

INTERPRET GEOMETRICTOLERANCING PER: ASME Y14.5

MATERIAL

FINISH

SEE NOTES

DRAWN

CHECKED

ENG APPR.

MFG APPR.

Q.A.

COMMENTS:

DATENAME LumenetixTITLE:

SIZE

BDWG. NO. REV

WEIGHT: SCALE: 1:1

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1

DO NOT SCALE DRAWING

2X 4.83.19

88.93.50

76.23.00

64.62.5

32.31.27

64.62.54

4.16

25.91.0

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFLUMENETIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUMENETIX IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

NEXT ASSY USED ON

APPLICATION

DIMENSIONS ARE IN MILLIMETERSTOLERANCES:ANGULAR: MACH 0.5ONE PLACE DECIMAL 0.5TWO PLACE DECIMAL 0.15

INTERPRET GEOMETRICTOLERANCING PER: ASME Y14.5

MATERIAL

FINISH

SEE NOTES

DRAWN

CHECKED

ENG APPR.

MFG APPR.

Q.A.

COMMENTS:

DATENAME LumenetixTITLE:

SIZE

BDWG. NO. REV

WEIGHT: SCALE: 1:1

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1

DO NOT SCALE DRAWING

Wiring Specifications

Pin Wire Color Pin Function Wiring Description

Lutron® EcoSystem

Interface(Input)

E1 VioletNon-polarized Bus Terminal

2 Position Terminal Block16 AWG solid wire

Lutron PN: C-CBL-216-GR-1E2 Violet / White

PowerP1 Red Power 12V DC or 24V DC (+) 2 Position Molex Pico-SPOX

Lumenetix PN: 28.002.001.01Length: 610 mm (24 inches)P2 Black Power Common (-)

Module Interface(LX or DMX Output)*

M1 N/A Reserved for future use

5 Position Molex Pico-SPOXLumenetix PN: 28.020.002.01Length: 610 mm (24 inches)

M2 N/A Reserved for future use

M3 Brown Digital Common

M4 Orange araya® Module Bus, Data -

M5Option-1: White with Orange Stripe

(Option-2: Green)araya® Module Bus, Data +

DMX Interface(Input)

D1 Option-1: Brown (Option-2: Black) Digital Common 3 Position Molex Pico-SPOX24 AWG stranded wire

Lumenetix PN Option-1: 28.020.001.02 (Lumenetix PN Option-2: 28.020.001.01)

Length: 610 mm (24 inches)

D2Option-1: White with Orange Stripe

(Option-2: Violet)DMX Data +

D3 Option-1: Orange (Option-2: Gray) DMX Data -

CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.

*LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE).

DMX Output is used with CTM 1B, CTM1C and DDM 1C.

EcoSystem Interface

E1 P1P2

M1M2

M3M4

M5E2

Module

Side view – araya®5 Digital Control Adapter

(Lutron® EcoSystem input)DCA-1A

Power

NOT USED

P1P2

M1M2

D2D3

M3M4

M5D1

ModulePower DMXNOT

USED

Side view – araya®5 Digital Control Adapter

(DMX input)DCA-1B

EcoSystem Interface

E1 P1P2

M1M2

M3M4

M5E2

ModulePower

NOT USED

Side view – araya®5 Digital Control Adapter

(Lutron® EcoSystem input)DCA-2

3 MECHANICAL DRAWING & WIRING SPECIFICATIONS

Page 6: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice6 | Digital Control Adapter Data Sheet

4.1 Lutron® EcoSystem Protocol

4 WIRING DIAGRAMS LUTRON® ECOSYSTEM PROTOCOL

Lutron® EcoSystem Protocol

EcoSystem technology is a control method for LEDs that provides addressing of individual fi xtures and status feedback. This makes it easy to digitally assign one or many fi xtures without complicated wiring. This opens up an entire suite of energy-saving, system-monitoring and system-control schemes where the design, setup and rezoning are all done within software, making the electrical and control design simple.

The araya®5 modules attached to different interface boards can be controlled independently or assigned to a single group by the EcoSystem controller.

The EcoSystem control is responsible for saving any confi guration settings. Once an interface board is assigned a pair of addresses, assigned addresses are saved in NVRAM. During the EcoSystem discovery process, the user pairs the desired dimming control in the controller to the Dim channel address in the interface board. The same applies for the CCT channel.

• 1 pair 16AWG Eco Loop, 900 feet (fi eld wiring).

• Maximum of 64 addresses on each loop.

EcoSystem Control Systems (recommended list)*

Quantum System

HomeWorks QS

Grafi k Eye QS Control Unit with EcoSystem

EnergiSavr Node with EcoSystem

Power Module with EcoSystem

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list.

® Specif icat ion Submittal page

Job Name:

Job Number:

Model Numbers:

Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller

369611b 1 10.22.13

MU

X

CO

M

MU

X

QS ECO 1 ECO 2

Test PruebaTester

Ta > 65 ºC

L N

Patent: 7,391,297

500-

1553

7 R

ev. A

NEC® Class 2

NEC® Class 2IEC PELV

0,5 N•m (5 in-lbs) Ta ≤ 65 °C www.lutron.com

u

Z096

65/75 ºC Cu Al

Power Module with EcoSystem® | Módulo de Potencia con EcoSystem® | Module d’Alimentation avec EcoSystem®

LQSE-2ECO-D

243C IND.CONT.EQ.

8 mm

1.800.523.9466

+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA

120 V~ 50/60 Hz 120 mA

Power Module with EcoSystemR

The Power Module with EcoSystemR unit is a DIN-rail mounted EcoSystem® Loop controller for EcoSystemR ballasts, drivers and devices. It provides EcoSystemR Loop power and control for two independent EcoSystemR Loops with up to 64 ballasts or drivers each.

Features• Provides EcoSystemR Loop power for two loops

of EcoSystemR ballasts or drivers (up to 250 mA per loop).

• Power failure memory retains control unitprogramming in the event of a power loss.

• Includes QS Link for connection to aHomeWorksR QS system.

• Power Module with EcoSystemR unit can be used ina HomeWorksR QS system to control and managelight in an entire home or building.

Up to 64 devices on each loop for Eco-1, and up to 32 devices on each loop for Eco-2

QS Link

Eco Loop 1

Eco Loop 2Fixture*

Power Module

Power Module with EcoSystem®

HomeWorksR QS Processor

GRAFIK EyeR QS

QS Contact Closure Interface

HomeWorksR QS Wallstation

120 / 230 V~ Control Power Up to 100

total QS devices

QS Power Supply

SivoiaR QS Shade / Drapery

Lutron EcoSystem Example

Fixture*

Fixture* Fixture*

*Fixture refers to a luminaire with one Lumenetix module, and with one address (DDM) or two addresses (CTM).

1

Lutron EcoSystem Controller Example

Page 7: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice7 | Digital Control Adapter Data Sheet

4 WIRING DIAGRAMS

4.1.1 Lutron® EcoSystem Field Wiring

LUTRON® ECOSYSTEM PROTOCOL

Lutron® EcoSystem Field Wiring

• EcoSystem Digital Loop can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring fl exibility..

• The Loop is polarity insensitive and can be wired in any topology..

• Consult all national and local electrical codes for separation requirements..

Wire Gauge Maximum EcoSystem-Compliant Loop Wire Length

4.0 mm2 (12 AWG) 671 m (2200 ft)

2.5 mm2 (14 AWG) 427 m (1400 ft)

1.5 mm2 (16 AWG) 275 m (900 ft)

1.0 mm2 (18 AWG) 175 m (570 ft)

Drain Wire ConnectionsDrain wire connections are required as follows.

Shielding

To add another level of protection from electromagnetic noise, a grounded shield is added over the twisted pair wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the fi eld. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate.

Method-1

A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the fi eld end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop.

Method-2

A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop.

Page 8: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice8 | Digital Control Adapter Data Sheet

4 WIRING DIAGRAMS

4.2 DMX512-A Protocol

DMX512-A PROTOCOL

DMX512-A is an acronym for Digital Multiplex, a communication protocol used to remotely control lighting dimmers and intelligent fi xtures. It is designed to provide a common communications standard between these lighting devices regardless of the manufacturer. The 512-A after the DMX refers to the number of control channels used on one network segment (often called a ‘universe’) of devices. In a simple dimming system, one channel controls the intensity of the fi xture. A single intelligent fi xture such as the araya5 requires several channels to control its various parameters (one channel each for DIM,

CCT, SAT, HUE).

DMX512A Specifi cations:• DMX 512-A (Controller).

• A universe is 512 Channels.

• DMX value is between 0 and 255, where 0 is off and 255 is full on.

• The maximum number of devices in a daisy-chain wire run is 32, which include the controller and opto-splitter.

• The maximum network wire run is a distance of up to 1600 feet for non-RDM systems and up to 1000 feet for RDM systems.

• One device functions as the master (DMX controller) on a network, while the rest function as slaves (mergers, splitters, intelligent fi xtures, etc.).

• Only the controller (master) transmits over the network, and all fi xtures receive the same data.

• The fi nal device in the daisy-chain must be terminated with a 120 ohm resistor between DMX+ and DMX- pins.

• It is recommended that the terminator for the fi nal device be located in the control panel, if it falls within the recommended wiring distance.

• All wiring must be in a continuous run and daisy-chained.

• Star wiring is only allowed in conjunction with an opto-splitter.

• Do not run DMX control cable in close proximity to AC power lines. EM spikes from switching of high-current devices such as HVAC equipment or generators will induce noise into the DMX cable.

• The shield must be carried through between modules and properly grounded at one point only.

• Connections to DMX512-A-RDM accessory board: wire size to be 24AWG, and solid or stranded cables may be used. Stranded wire used must be tinned or installed with ferule connector.

RDM

DMX512-A control protocol that enables Remote Device Management for two-way communications for confi guration, monitoring and system setup. Allows two way communication between lighting controller and the fi xtures. Allows for remote setting of DMX start addressing. RDM signals are sent back the other way, but not constantly. Controller can ask one or more devices for query feedback. RDM packets are inserted in-between the existing DMX data packets being used to control the lighting. The DMX Control Console will broadcast up to 512 channels over one DMX cable (max. run of 1000 feet for RDM). Some of these channels may not be used, but will still be transmitted, as required by the protocol. It must be set to a desired channel (001, 002. 003. 004, etc.) to control the connected light fi xture. This is usually accomplished using RDM. This desired ‘channel’ is commonly known as the DMX address. When addressing fi xtures, it is not recommended to skip addresses.

When RDM is not available with the control system, it is permissible to use the Lumenetix commissioning tool (the araya5 Tunable Color 2.0 iOS App) to set

the address of the slots. The instructions to confi gure the DMX channels can be found in the separate araya5 Tunable Color Instruction Manual.

The DMX512-A interface follows the ANSI E1.11-2008 (R21013) standard. Four address slots are allocated to each interface board and control the Dim

level, CCT, Saturation and Hue of the araya5 modules connected to the board.

Default DMX512-A Slot Allocation:

Slot Function

1 Dim Level

2 CCT

3 Saturation Level

4 Hue

DMX512-A Protocol

Page 9: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice9 | Digital Control Adapter Data Sheet

4.2.1 DMX512-A Electrical Specifications

4 WIRING DIAGRAMSDMX512-A PROTOCOL

DMX512-A Electrical Specifi cations

Parameter Range Remarks

ESD Protection ±15KV (air), ±8KV (conducted) Per IEC 61000-4-2

Termination Recommended The DMX512 bus termination rules apply

Directionality Receive only

Frequency stability ±20ppm

Load per port 1/256 1/8 of Nominal RS-485

Isolation 3KVrms

DMX512-A Control Systems (recommended list)Choreo

Cognito

Crestron Greenlight System

Entec

ETC Mosaic

ETC Paradigm

Fresco

Interactive Technologies

Lutron HomeWorks QS

Lutron Quantum

Nicolaudie

Pathway Connectivity

Pharos

Traxon Ecue

Vantage Controls

*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list.

DMX512-A Recommended Internal / Field Wiring

TMB Cable ProPlex DMXPC224T: 2-pair DMX512 cable, overall foil and braid shielding with drain wire. UV and fungus resistant. Fully rated for installations, yet easy

handling for light duty portable applications.

PC224TW: Same as above, with white jacket.

For use as DMX in/out under one jacket:

PC244T: Two individually shielded pairs and drain wires. UV resistant. Color coded foil shielding for easy reference.

Page 10: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice10 | Digital Control Adapter Data Sheet

4 WIRING DIAGRAMS

4.2.2 DMX512-A Recommended Field Wiring

DMX512-A PROTOCOL

DMX512-A Recommended Field WiringLiberty 24-2P-485 (Non-Plenum), 24 AWG, 2 pair dual 120 ohm, 11.2 pf/ft low capacitance (Wago, XLR and PHX connectors)Liberty 24-2P-P485 (Plenum), 24 AWG, 2 pair dual 120 ohm, 11.2 pf/ft low capacitance (XLR and PHX connectors)Belden #9842 (Non-Plenum), 24 AWG, 2 pair dual shielded 120 ohm, 12.8 pf/ft low capacitance (XLR and PHX connectors)Belden #89842 (Plenum), 24 AWG, 2 pair dual shielded 120 ohm, 12.8 pf/ft low capacitance (XLR and PHX connectors)

Please refer to wire manufacturer’s lighting catalog for and/equals as required by code.

Category Wire or EqualThe Entertainment Services and Technology Association (ESTA) does not defi ne a maximum run length for DMX over Cat5 since many factors will affect the maximum run length, such as number of devices, number of splices in the cable, the strength of the DMX transmitter(s), if Remote Device Management (RDM) is being used, and sources of interference. ESTA does state (again, in ANSI E1.21-2):

“A properly selected and installed DMX512 cable should provide acceptable signal strength for runs of 300m (1000ft). Please note that the technical requirements, such as run-length and topology for other networking technologies, such as Ethernet, should be considered if using the installed cable for another networking technology in the future is anticipated.”

Cat5 or equivalent is not preferred as a portable cable since it is not as rugged as other DMX cables. Male RJ45 connectors are especially prone to breakage over repeated re-connections.

LUMENETIX RECOMMENDATION:

CAT 5E -150 FEET

CRESTRON

DM-CBL-8G-NP

DM-CBL-8G-P

CAT 7- 330 FEET

CRESTRON

DM-CBL-ULTRA-NP

DM-CBL-ULTRA-P

DMX512-A Recommended Field Connectors (or Equal)WAGO 221

PHOENIX CONTACT

XLR NEUTRIK

CRESTRON

RJ45 DM -8G-CONN

RJ45 IDC DM-CONN

DMX512-A Wiring Connections

Signal Description Pin Colors (4-Pair Cable) Pin Colors (2-Pair Cable)3-pin XLR connector

5-Pin XLR connector

5-Pin PHX connector

Signal Common White/Brown and Brown White/Blue and Blue 1 1 1

Data (-) Primary Data Link Orange Orange 2 2 2

Data (+) Primary Data Link White/Orange White/Orange 3 3 3

Data2 (-), or not used Optional Secondary Data Link 4 4

Data2 (+), or not used Optional Secondary Data Link 5 5

RJ-45 Connector Pin-Out (T568B)XLR Connectors (5-Pin)

+-

Page 11: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice11 | Digital Control Adapter Data Sheet

4 WIRING DIAGRAMS

4.2.3 DMX512-A Controller Example

DMX512-A PROTOCOL

DMX512-A Drain Wire Connections

Drain wire connections are required as follows.

Shielding

To add another level of protection from electromagnetic noise, a grounded shield is added over the twisted pair wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the fi eld. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate.

Method-1

A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the fi eld end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop.

Method-2

A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop.

DMX512-A Controller Example

Up to 30devices on each loop

Bus

DMX Loop 1

DMX Loop 2

Power Module

DMXController

Processor TouchPanel

Contact Closure Interface

Wallstation

120 / 230 V~

Control Power total devices

Power Supply

Shade / Drapery

DMX512A Example

RDM Merger / Splitter

*Fixture refers to a luminaire with one Lumenetix module, and with one address (DDM) or four addresses (CTM).

Page 12: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice12 | Digital Control Adapter Data Sheet

4.3.1 Lutron® EcoSystem Input; DCA-1A (24V DC)

DDM0 (one channel); CTM0 (two channel)

4 WIRING DIAGRAMSLUTRON® ECOSYSTEM WIRING DIAGRAMS

Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM0 (one channel) / CTM0 (two channel) — 24V

CTM0DDM0

24V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

e

PN: 28.002.001.01 Digital Control Adapter

PN: 28.002.001.01

PN: 28.020.002.01

Line in Voltage(refer to power supply)

PN: 28.002.002.01

White/Blue and Gray/Violet0-10V wires are tied together

Whi

te /

Ora

nge

JUNCTION BOX

FIXTURE

The Constant Hot/Live must not be wired to a switching device. This may be put on a relay for maintenance.

NOT USED

E1Lutron EcoSystem Controller

E2

Viol

et

Whi

te /

Viol

et

Strip

es

Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.

Adapter is con�gured at OEM factory for EcoSystem inputs.

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

Notes:

1. 24V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for EcoSystem inputs.

4. DCA may be installed in the luminaire only.

5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.

6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.

7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.

8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K and 2700 - 6000K.

9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damagethe Digital Control Adapter unit.

10. LX Output used with this system.

DCA-1A A

ND DCA-1

B DIS

CONTINUED

-

NO LONGER

AVAILABLE

Page 13: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice13 | Digital Control Adapter Data Sheet

4.3.2 Lutron®

EcoSystem Input; DCA-1A (12V DC) DDM1 (one channel); CTM1 (two channel)

4 WIRING DIAGRAMSLUTRON® ECOSYSTEM WIRING DIAGRAMS

Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1 (one channel) / CTM1 (two channel) — 12V

12V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

eW

hite

/ O

rang

e

PN: 28.002.001.01

PN: 28.002.002.01

Digital Control Adapter

PN: 28.002.001.01

CTM1DDM1

Line in Voltage(refer to power supply) The Constant Hot/Live must not be

wired to a switching device. This may be put on a relay for maintenance.

White/Blue and Gray/Violet 0-10V wires are tied together

JUNCTION BOX

FIXTURE

NOT USED

E1Lutron EcoSystem Controller

E2

Viol

et

Whi

te /

Viol

et

Strip

es

Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.

Adapter is con�gured at OEM factory for EcoSystem inputs.

PN: 28.020.002.01

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

Notes:

1. 12V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for EcoSystem inputs.

4. DCA may be installed in the luminaire only.

5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.

6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.

7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.

8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K.

9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damagethe Digital Control Adapter unit.

10. LX Output used with this system.

DCA-1A A

ND DCA-1

B DIS

CONTINUED

-

NO LONGER

AVAILABLE

Page 14: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice14 | Digital Control Adapter Data Sheet

4.4.1 DMX Input; DCA-1B (24V DC) DDM0; CTM0

4 WIRING DIAGRAMS

DMX Input; Digital Control Adapter (DCA)DDM0 / CTM0 — 24V

DMX512-A WIRING DIAGRAMS

Notes:

1. 24V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for DMX (including Bluetooth) inputs.

4. DCA may be installed in the luminaire only.

5. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damagethe Digital Control Adapter unit.

6. LX Output used with this system.

CTM0DDM0

24V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

e

PN: 28.002.001.01 Digital Control Adapter

PN: 28.002.001.01

PN: 28.020.002.01

Line in Voltage(refer to power supply)

PN: 28.002.002.01

White/Blue and Gray/Violet0-10V wires are tied together

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

Whi

te /

Ora

nge

NOT USED

For DMX inputs:OPTION-1Brown is Digital Common.White with Orange Stripe is Data Positive.Orange is Data Negative.

DMX (incl. Bluetooth)

PN Option-1: 28.020.001.02PN Option-2:28.020.001.01

Brow

n

Ora

nge

JUNCTION BOX

Whi

te /

Ora

nge

FIXTURE

The Constant Hot/Live must not be wired to a switching device. This may be put on a relay for maintenance.

OPTION-2Black is Digital Common.Violet is Data Positive.Gray is Data Negative.

DCA-1A A

ND DCA-1

B DIS

CONTINUED

-

NO LONGER

AVAILABLE

Page 15: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice15 | Digital Control Adapter Data Sheet

4.4.2 DMX Input; DCA-1B (12V DC) DDM1; CTM1

4 WIRING DIAGRAMS

DMX Input; Digital Control Adapter (DCA)DDM1 / CTM1 — 12V

DMX512-A WIRING DIAGRAMS

Notes:

1. 12V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for DMX (including Bluetooth) inputs.

4. DCA may be installed in the luminaire only.

5. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.

6. LX Output used with this system.

12V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

eW

hite

/ O

rang

e

PN: 28.002.001.01

PN: 28.002.002.01

Digital Control Adapter

PN: 28.002.001.01

CTM1DDM1

PN: 28.020.002.01

Line in Voltage(refer to power supply) The Constant Hot/Live must not be

wired to a switching device. This may be put on a relay for maintenance.

White/Blue and Gray/Violet 0-10V wires are tied together

DMX (incl. Bluetooth)

NOT USED

Brow

n

Ora

nge

JUNCTION BOX

FIXTURE

Whi

te /

Ora

nge

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

For DMX inputs:OPTION-1Brown is Digital Common.White with Orange Stripe is Data Positive.Orange is Data Negative.

PN Option-1: 28.020.001.02PN Option-2:28.020.001.01

OPTION-2Black is Digital Common.Violet is Data Positive.Gray is Data Negative.

DCA-1A A

ND DCA-1

B DIS

CONTINUED

-

NO LONGER

AVAILA

BLE

Page 16: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice16 | Digital Control Adapter Data Sheet

4.5.1 Lutron®

EcoSystem Input; DCA-2 (24V DC) DDM1C, Bluetooth-integrated (one channel) CTM1C, Bluetooth-integrated (two channel)

4 WIRING DIAGRAMSLUTRON

® ECOSYSTEM WIRING DIAGRAMS

Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1C (one channel) / CTM1C (two channel) — 24V

24V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

eW

hite

/ O

rang

e

PN: 28.002.001.01

PN: 28.002.002.01

Digital Control Adapter

PN: 28.002.001.01

CTM1DDM1

Line in Voltage(refer to power supply) The Constant Hot/Live must not be

wired to a switching device. This may be put on a relay for maintenance.

JUNCTION BOX

FIXTURE

NOT USED

E1Lutron EcoSystem Controller

E2

Viol

et

Whi

te /

Viol

et

Strip

es

Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.

Adapter is con�gured at OEM factory for EcoSystem inputs.

PN: 28.020.002.01Minimum requirement is a DMX type wire.

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

White/Blue and Gray/Violet 0-10V wires can be tied together or left open.

Notes:

1. 24V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.

4. DCA may be installed in the luminaire only.

5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.

6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.

7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.

8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 8000K.

9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.

10. DMX Output used with this system.

Page 17: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice17 | Digital Control Adapter Data Sheet

4.5.2 Lutron®

EcoSystem Input; DCA-2 (12V DC) DDM1C, Bluetooth-integrated (one channel) CTM1C, Bluetooth-integrated (two channel)

4 WIRING DIAGRAMSLUTRON

® ECOSYSTEM WIRING DIAGRAMS

Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1C (one channel) / CTM1C (two channel) — 12V

12V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

eW

hite

/ O

rang

e

PN: 28.002.001.01

PN: 28.002.002.01

Digital Control Adapter

PN: 28.002.001.01

CTM1DDM1

Line in Voltage(refer to power supply) The Constant Hot/Live must not be

wired to a switching device. This may be put on a relay for maintenance.

White/Blue and Gray/Violet 0-10V wires can be tied together or left open.

JUNCTION BOX

FIXTURE

NOT USED

E1Lutron EcoSystem Controller

E2

Viol

et

Whi

te /

Viol

et

Strip

es

Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.

Adapter is con�gured at OEM factory for EcoSystem inputs.

PN: 28.020.002.01Minimum requirement is a DMX type wire.

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

Notes:

1. 12V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.

4. DCA may be installed in the luminaire only.

5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.

6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.

7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.

8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 8000K.

9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.

10. DMX Output used with this system.

Page 18: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Digital Control Adapter

Revised 10.22.19 | Specifications subject to change without notice18 | Digital Control Adapter Data Sheet

4.5.3 Lutron®

EcoSystem Input; DCA-2 (12V DC) DDM1B, Bluetooth-integrated (one channel) CTM1B, Bluetooth-integrated (two channel)

4 WIRING DIAGRAMSLUTRON

® ECOSYSTEM WIRING DIAGRAMS

Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1B (one channel) / CTM1B (two channel) — 12V

12V DC, Class 2 AC to DC Power Supply

+ –

Neutral Hot

Red

Blac

k

Blac

k

Whi

te

Brow

nO

rang

eW

hite

/ O

rang

e

PN: 28.002.001.01

PN: 28.002.002.01

Digital Control Adapter

PN: 28.002.001.01

CTM1DDM1

Line in Voltage(refer to power supply) The Constant Hot/Live must not be

wired to a switching device. This may be put on a relay for maintenance.

White/Blue and Gray/Violet 0-10V wires are tied together

JUNCTION BOX

FIXTURE

NOT USED

E1Lutron EcoSystem Controller

E2

Viol

et

Whi

te /

Viol

et

Strip

es

Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.

Adapter is con�gured at OEM factory for EcoSystem inputs.

PN: 28.020.002.01

Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.

Notes:

1. 12V power (red/black) is Class-2 rated.

2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.

3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.

4. DCA may be installed in the luminaire only.

5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.

6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.

7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.

8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K.

9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.

10. DMX Output used with this system.

Page 19: Digital Control Adapter Data Sheet...HomeWorksR QS Closure Processor GRAFIK EyeR QS QS Contact Interface HomeWorksR QS Wallstation 120/230 V~ Control Power Up to 100 total QS devices

Lumenetix Inc.4742 Scotts Valley DriveScotts Valley, CA 95066877.805.7284www.lumenetix.com