1
Digital Clampmeters AC / DC / TRMS D 600A, 2000A Accuracy ±(3.5%rdg + 5dgt) Overload 2000A AC max. for 1 min. 6V, 60V, 600V (auto-ranging) Accuracy ±(1%rdg + 6dgt) (50~60Hz) ±(2%rdg + 4dgt) (40~500Hz) Overload 600V DC / AC rms. 600A, 2000A Accuracy ±(2.5%rdg + 5dgt) Overload 2000A DC max. for 1 min. 600mV, 6V, 60V, 600V (auto) Accuracy ±(0.5%rdg + 5dgt) Overload 600V DC / AC rms. 600V, 6kV, 60kV, 600kV, 6MV, 60MV (auto-ranging) Accuracy ±(0.3%rdg + 8dgt) 600V ±(0.3%rdg + 5dgt) 6-600kV ±(0.5%rdg + 5dgt) 6MV ±(2%rdg + 5dgt) 60MV Overload 600V DC / AC rms. 10.00Hz - 999.9KHz (auto- ranging) Accuracy ±(0.1%rdg + 2dgt) (for non distorted waveforms only) Overload 200V DC / AC rms. 1% to 90% (Auto) Accuracy ±(0.5%rdg+5dgt) 6nF, 60nF, 600nF, 6 mF, 40mF (auto-ranging) Accuracy ±(3%rdg+40dgt) on 6nF (Use D REL) ±(3%rdg+10dgt) on 60nF to 6mF ±(6%rdg+10dgts) on 40mF Overload 600V DC / AC rms. Audible continuity, Diode Test function One 9V Battery, Eveready Type 216 or Equivalent 25 hours (typical) " " is Indicated "OL" or "-OL" is indicated 250 x 100 x 46 mm 380 gms Including Battery (approx.) Cable Dia 55mm max. 100Hz, 1kHz, 10kHz, 100kHz, 500kHz (auto-ranging) (For non distorted waveforms only) Accuracy ±(0.1%rdg+2dgts) Audible Continuity, Diode Test function One 9 Volt battery, type Eveready 216 or equivalent. 150 hours (typical) ” is indicated. 600VDC or AC rms overload protection in DCV, ACV, Diode, Ohms, Hz, Continuity. 250 x 100 x 46 mm 380 gms (approx.) Including Battery Cable Dia 55mm max. D 400A, 1000A Accuracy ±(2.5%rdg+5dgt) (50-60Hz) ±(3.5%rdg+5dgt) (40-500Hz) Overload 1000A AC max. for 1 min. 4V,40V,400V,600V (Auto & Manual Ranging) Accuracy ±(0.75%rdg+4dgt) (50-60Hz) ±(2%rdg+4dgt) (40-500Hz) 400A, 1200A Accuracy ±(1.5%rdg+5dgts) (upto 700A) ±(2%rdg+5dgts) (700 - 1200A) Overload 1200 A DC max. for 1 min. 400mV, 4V, 40V, 400V, 600V (Auto & Manual Ranging) Accuracy ±(0.25%rdg + 1dgts) (400mV - 400V) ±(0.25%rdg + 3dgts) on 600V 400V, 4kV, 40kV, 400kV, 4000kV, 40MV (Auto & Manual Ranging) Accuracy ±(0.3%rdg+5dgt) on 400V ±(0.3%rdg+1dgt) on 4kV- 400kV ±(0.5%rdg+1dgt) on 4000kV ±(2.0%rdg+4dgt) on 40MV 4nF, 40nF, 400nF, 4mF, 40mF (Auto & Manual Ranging) Accuracy ±(3%rdg+20dgt) on 4nF (Use D ZERO) ±(3%rdg+4dgt) on 40nF to 20mF ±(6%rdg+4dgts) above 20 mF Supplied with a pair of Test Leads, Battery , Inst. (installed) Manual & Carrying Case Supplied with a pair of test leads, carrying case, battery (installed) & Inst. manual

Digital Clampmeters AC / DC / TRMS3.imimg.com/data3/VK/DM/MY-1924495/digital-clampmeters...79 Digital Clampmeters AC / DC / TRMS 60SegmentBargraph, D 600A,2000A Accuracy ±(3.5%rdg

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Digital Clampmeters AC / DC / TRMS3.imimg.com/data3/VK/DM/MY-1924495/digital-clampmeters...79 Digital Clampmeters AC / DC / TRMS 60SegmentBargraph, D 600A,2000A Accuracy ±(3.5%rdg

79

Digital Clampmeters AC / DC / TRMS

60 Segment Bargraph,D

600A, 2000A

Accuracy ±(3.5%rdg + 5dgt)

Overload 2000A AC max. for 1 min.

6V, 60V, 600V (auto-ranging)

Accuracy ±(1%rdg + 6dgt) (50~60Hz)

±(2%rdg + 4dgt) (40~500Hz)

Overload 600V DC / AC rms.

600A, 2000A

Accuracy ±(2.5%rdg + 5dgt)

Overload 2000A DC max. for 1 min.

600mV, 6V, 60V, 600V (auto)

Accuracy ±(0.5%rdg + 5dgt)

Overload 600V DC / AC rms.

600V, 6kV, 60kV, 600kV,

6MV, 60MV (auto-ranging)

Accuracy ±(0.3%rdg + 8dgt) 600V

±(0.3%rdg + 5dgt) 6-600kV

±(0.5%rdg + 5dgt) 6MV

±(2%rdg + 5dgt) 60MV

Overload 600V DC / AC rms.

10.00Hz - 999.9KHz (auto-

ranging)

Accuracy ±(0.1%rdg + 2dgt)

(for non distorted waveforms only)

Overload 200V DC / AC rms.

1% to 90% (Auto)

Accuracy ±(0.5%rdg+5dgt)

6nF, 60nF, 600nF, 6mF, 40mF

(auto-ranging)

Accuracy ±(3%rdg+40dgt) on 6nF

(Use D REL)

±(3%rdg+10dgt) on 60nF

to 6mF

±(6%rdg+10dgts) on 40mF

Overload 600V DC / AC rms.

Audible continuity,

Diode Test function

One 9V Battery, Eveready

Type 216 or Equivalent

25 hours (typical)

" " is Indicated

"OL" or "-OL" is indicated

250 x 100 x 46 mm

380 gms Including Battery (approx.)

Cable Dia 55mm max.

100Hz, 1kHz, 10kHz,

100kHz, 500kHz

(auto-ranging) (For non

distorted waveforms only)

Accuracy ±(0.1%rdg+2dgts)

Audible Continuity,

Diode Test function

One 9 Volt battery, type

Eveready 216 or equivalent.

150 hours (typical)

“ ” is indicated.

600VDC or AC rms overload

protection in DCV, ACV,

Diode, Ohms, Hz,

Continuity.

250 x 100 x 46 mm

380 gms (approx.)Including Battery

Cable Dia 55mm max.

D

400A, 1000A

Accuracy ±(2.5%rdg+5dgt)

(50-60Hz)

±(3.5%rdg+5dgt)

(40-500Hz)

Overload 1000A AC max. for 1 min.

4V,40V,400V,600V

(Auto & Manual Ranging)

Accuracy ±(0.75%rdg+4dgt) (50-60Hz)

±(2%rdg+4dgt) (40-500Hz)

400A, 1200A

Accuracy ±(1.5%rdg+5dgts) (upto 700A)

±(2%rdg+5dgts) (700 - 1200A)

Overload 1200 A DC max. for 1 min.

400mV, 4V, 40V, 400V, 600V

(Auto & Manual Ranging)

Accuracy ±(0.25%rdg + 1dgts)

(400mV - 400V)

±(0.25%rdg + 3dgts) on 600V

400V, 4kV, 40kV, 400kV,

4000kV, 40MV

(Auto & Manual Ranging)

Accuracy ±(0.3%rdg+5dgt) on 400V

±(0.3%rdg+1dgt) on 4kV -

400kV

±(0.5%rdg+1dgt) on 4000kV

±(2.0%rdg+4dgt) on 40MV

4nF, 40nF, 400nF, 4mF, 40mF

(Auto & Manual Ranging)

Accuracy ±(3%rdg+20dgt) on 4nF

(Use D ZERO)

±(3%rdg+4dgt) on 40nF to 20mF

±(6%rdg+4dgts)

above 20mF

Supplied with a pair of Test

Leads, Battery , Inst.(installed)

Manual & Carrying Case

Supplied with a pair of test

leads, carrying case, battery

(installed) & Inst. manual