Catalog Sections AIR CONDITIONERS 1,000 BTUH TO 20,000 BTUH AIR CONDITIONER ACCESSORIES AIR TO AIR HEAT EXCHANGERS ENCLOSURE ACCESSORIES FILTERED FAN PACKAGES ENCLOSURE PACKAGES GENERAL INFORMATION PRICING INFORMATION Thank you for receiving our catalog. We look forward to working with your company to remedy heat related issues inside your electrical enclosures. Please do not hesitate to call us for product assistance or application sizing. Get the Edge...Get Thermal Edge (972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Digital Binder 2012_01

Embed Size (px)

DESCRIPTION

Thermal Edge products, pricing and technical information

Citation preview

Catalog Sections

AIR CONDITIONERS 1,000 BTUH TO 20,000 BTUH

AIR CONDITIONER ACCESSORIES

AIR TO AIR HEAT EXCHANGERS

ENCLOSURE ACCESSORIES

FILTERED FAN PACKAGES

ENCLOSURE PACKAGES

GENERAL INFORMATION

PRICING INFORMATION

Thank you for receiving our catalog. We look forward to working with your company to remedy heat related issues inside your electrical enclosures. Please do not hesitate to call us for product assistance or application sizing. Get the Edge...Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

(972) 580-0200 or (888) 580-0202 • URL: www.thermal-edge.com • Email: [email protected]

MODEL BTU/HOUR VOLTAGE/ PHASE/HZ.

RUNNING AMPS

MAXIMUM AMBIENT TEMP.

MAXIMUM INTEGRATED HEAT

IN WATTS

H X W X D

SHIP WEIGHT

NE010126 1,000 120/1/60 3.44 125°F NA 22” x 11.8” x 8.5” 67

NE010236 1,000 230/1/60 2.67 125°F NA 22” x 11.8” x 8.5” 67

CS011126 1,000-2,000 120/1/60 2.70 131°F 325 17” x 7” x 7” 43

NE015126 1,500 120/1/60 3.89 125°F NA 22” x 11.8” x 8.5” 67

NE015236 1,500 230/1/60 2.67 125°F NA 22” x 11.8” x 8.5” 67

NE020126 2,000 120/1/60 3.76 125°F 1000 32“ x 11.8“ x 9.5“ 111

NE020236 2,000 230/1/60 3.07 125°F 1000 32“ x 11.8“ x 9.5“ 116

NE020486 2,000 480/1/60 1.93 131°F 1000 38” x 11.8” x 9.5” 141

CS020126 2,000 120/1/60 3.36 125°F 500 20” x 10” x 10” 56

CS020236 2,000 230/1/60 2.00 125°F 500 20” x 10” x 10” 59

NE030126 3,000 120/1/60 5.15 131°F 1000 32” x 11.8“ x 9.5” 111

NE030236 3,000 230/1/60 3.07 131°F 1000 32” x 11.8“ x 9.5” 116

NE030486 3,000 480/1/60 1.51 131°F 1000 38” x 11.8” x 9.5” 141

NE040126 4,000 120/1/60 5.53 131°F 1000 32” x 11.8“ x 9.5” 111

NE040236 4,000 230/1/60 3.07 125°F 1000 32” x 11.8“ x 9.5” 116

NE040486 4,000 480/1/60 1.51 125°F 1000 38” x 11.8“ x 9.5” 141

NE050126 5,000 120/1/60 7.26 125°F 1000 36“ x 11.8“ x 15.1” 139

NE050236 5,000 230/1/60 3.76 125°F 1000 36“ x 11.8“ x 15.1” 140

NE050486 5,000 480/1/60 1.44 125°F 1000 44.63” x 11.8” x 15.1” 189

NE060126 6,000 120/1/60 7.83 125°F 1000 36“ x 11.8“ x 15.1” 139

NE060236 6,000 230/1/60 4.80 125°F 1000 36“ x 11.8“ x 15.1” 140

NE060486 6,000 480/1/60 1.80 125°F 1000 44.63” x 11.8” x 15.1” 189

WF060126 6,000 120/1/60 13.0 125°F 1000 36.8” x 19” x 10.5” 136

WF060236 6,000 230/1/6 6.80 125°F 1000 36.8” x 19” x 10.5” 161

NE080126 8,000 120/1/60 7.83 125°F 1000 36“ x 11.8“ x 15.1” 139

NE080236 8,000 230/1/60 4.80 125°F 1000 36“ x 11.8“ x 15.1” 140

NE080486 8,000 480/1/60 1.80 125°F 1000 44.63” x 11.8” x 15.1” 189

WF080126 8,000 120/1/60 12.30 131°F 1000 36.8” x 19” x 10.5” 136

WF080236 8,000 230/1/60 6.00 131°F 1000 36.8” x 19” x 10.5” 161

HC101126 10,000 120/1/60 19.4 131°F 1500 48” x 15.9” x 15.1” 183

HC101236 10,000 230/1/60 8.20 131°F 1500 48” x 15.9” x 15.1” 186

HC101486 10,000 480/1/60 3.93 131°F 1500 57.6” x 15.9” x 15.1” 244

HC121126 12,000 120/1/60 19.4 131°F 1500 48” x 15.9” x 15.1” 183

HC121236 12,000 230/1/60 8.20 131°F 1500 48” x 15.9” x 15.1” 186

HC121486 12,000 480/1/60 3.93 131°F 1500 57.6” x 15.9” x 15.1” 244

HC151236 15,000 230/1/60 11.3 131°F 1500 48” x 15.9” x 15.1” 191

HC151486 15,000 480/1/60 5.41 131°F 1500 57.6” x 15.9” x 15.1” 256

HC201236 20,000 230/1/60 13.7 131°F 1500 56.1” x 23” x 15” 226

HC201486 20,000 480/1/60 6.56 131°F 1500 65.7” x 23” x 15” 342

AIR CONDITIONER PRODUCT LINE

Temperature Control Solutions for Electrical Enclosures

2012/01 

Web app @ thermal‐edge.com 

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

CLOSED LOOP AIR CONDITIONERS

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault

indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Material Voltage/Hz.

Running Amps

Max. Amb Temperature

H x W x D

Weight (lbs.)Unit / Ship

NE010-126-12 1000 Powder coated steel 120/1/60 3.44 125°F 22” x 11.8” x 8.5” 52 / 67

NE010-126-04 1000 Powder coated steel 120/1/60 3.44 125°F 22” x 11.8” x 8.5” 52 / 67

NE010-126-4X 1000 Stainless steel 120/1/60 3.44 125°F 22” x 11.8” x 8.5” 52 / 67

NE010-236-04 1000 Powder coated steel 230/1/60 2.67 125°F 22” x 11.8” x 8.5” 52 / 67

NE010-236-4X 1000 Stainless steel 230/1/60 2.67 125°F 22” x 11.8” x 8.5” 52 / 67

NE010-236-12 1000 Powder coated steel 230/1/60 2.67 125°F 22” x 11.8” x 8.5” 52 / 67

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System

1000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Testing done under controlled conditions. Actual performance may vary.

2012/01 UL File # SA32252

All information subject to change without notice

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 8” enclosure Filter free design Unit Efficiency Temperature operated blower control reduces pow-

er inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System Redundant System

1,000 - 2,000 BTU/H Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

Model BTU/H Material Volt./Hz. Running Amps

Max. Ambient Temperature

H x W x D Weight (lbs.) Unit / Ship

CS011-126-12 1000 - 2000 Powder coated steel 120/1/60 2.7 131°F 17” x 7” x 7” 30 / 43 CS011-126-04 1000 - 2000 Powder coated steel 120/1/60 2.7 131°F 17” x 7” x 7” 30 / 43 CS011-126-4X 1000 - 2000 Stainless steel 120/1/60 2.7 131°F 17” x 7” x 7” 30 / 43

T CS011 3 .

D

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

2012/01

Testing done under controlled conditions. Actual performance may vary.

All information subject to change without notice UL File # SA32252

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout feature Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy High efficiency compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage/Hz.

Running Amps

Max. Ambient Temperature

Weight (lbs.) Unit / Ship

NE015-126-12 1500 120/1/60 3.89 125°F 52 / 67

NE015-236-12 1500 230/1/60 2.67 125°F 52 / 67

H x W x D

22” x 11.8” x 8.5”

22” x 11.8” x 8.5”

Material

Powder coated steel

Powder coated steel

NE015-126-04 1500 Powder coated steel 120/1/60 3.89 125°F 22” x 11.8” x 8.5” 52 / 67

NE015-126-4X 1500 Stainless steel 120/1/60 3.89 125°F 22” x 11.8” x 8.5” 52 / 67

NE015-236-04 1500 Powder coated steel 230/1/60 2.67 125°F 22” x 11.8” x 8.5” 52 / 67

NE015-236-4X 1500 Stainless steel 230/1/60 2.67 125°F 22” x 11.8” x 8.5” 52 / 67

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options

1500 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File # SA32252

Testing done under controlled conditions. Actual performance may vary

2012/01 All information subject to change without notice

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System Hazardous Location Units Redundant Systems

2000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

Model BTU/H Material Volt./Hz. Running Amps

Max. Ambient Temperature

H x W x D Weight (lbs.)Unit / Ship

NE020-126-12 2000 Powder coated steel 120/1/60 3.76 125°F 32” x 11.8” x 9.5” 94 / 111 NE020-126-04 2000 Powder coated steel 120/1/60 3.76 125°F 32” x 11.8” x 9.5” 94 / 111 NE020-126-4X 2000 Stainless steel 120/1/60 3.76 125°F 32” x 11.8” x 9.5” 94 / 111

NE020-236-04 2000 Powder coated steel 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

NE020-486-04 2000 Powder coated steel 480/1/60 0.93 125°F 38” x 11.8” x 9.5” 123 / 141 NE020-486-4X 2000 Stainless steel 480/1/60 0.93 125°F 38” x 11.8” x 9.5” 123 / 141

NE020-236-12 2000 Powder coated steel 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

NE020-236-4X 2000 Stainless steel 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116 NE020-486-12 2000 Powder coated steel 480/1/60 0.93 125°F 38” x 11.8” x 9.5” 123 /141

11.8” wide

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

2012/01 UL File # SA32252

Testing done under controlled conditions. Actual performance may vary.

All information subject to change without notice

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Management System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient Rotary Compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Material Voltage/Hz.

Running Amps

Max. Ambient

Temp

H x W x D

Weight (lbs.) Unit / Ship

CS02-0126-12 2000 Powder coated steel 120V/1/60 3.36 125°F 20” x 10” x 10” 42 / 56

CS02-0126-04 2000 Powder coated steel 120V/1/60 3.36 125°F 20” x 10” x 10” 42 / 56

CS02-0126-4X 2000 304 Stainless 120V/1/60 3.36 125°F 20” x 10” x 10” 42 / 56

CS02-0236-12 2000 Powder coated steel 230V/1/60 2.0 125°F 20” x 10” x 10” 45 / 59

CS02-0236-04 2000 Powder coated steel 230V/1/60 2.0 125°F 20” x 10” x 10” 45 / 59

CS02-0236-4X 2000 304 Stainless 230V/1/60 2.0 125°F 20” x 10” x 10” 45 / 59

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heater System

2000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Get the Edge...Get Thermal Edge

Temperature Control Solutions for Electrical Enclosures

btuh

3253.9

2302.8

1829.7

3208.2

2807.8

2652

0

500

1000

1500

2000

2500

3000

3500

100 105 110 115 120 125

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Testing done under controlled conditions. Actual performance may vary

UL File # SA32252

All information subject to change without notice

2012/01

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain capacity over

a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System Hazardous Location Units Redundant Systems

3000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

Model BTU/H Material Volt./Hz. Running Amps

Max. Ambient Temperature

H x W x D Weight (lbs.) Unit / Ship

NE030-126-12 3000 Powder coated steel 120/1/60 5.15 125°F 32” x 11.8” x 9.5” 94 / 111 NE030-126-04 3000 Powder coated steel 120/1/60 5.15 125°F 32” x 11.8” x 9.5” 94 / 111 NE030-126-4X 3000 Stainless steel 120/1/60 5.15 125°F 32” x 11.8” x 9.5” 94 / 111

NE030-486-12 3000 Powder coated steel 480/1/60 1.51 125°F 38” x 11.8” x 9.5” 123 / 141 NE030-486-04 3000 Powder coated steel 480/1/60 1.51 125°F 38” x 11.8” x 9.5” 123 / 141 NE030-486-4X 3000 Stainless steel 480/1/60 1.51 125°F 38” x 11.8” x 9.5” 123 / 141

NE030-236-4X 3000 Stainless steel 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

NE030-236-12 3000 Powder coated steel 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116 NE030-236-04 3000 Powder coated steel 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

11.8” wide

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

All information subject to change without notice 2012/01

Testing done under controlled conditions. Actual performance may vary.

UL File # SA32252

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with a rigid chassis and seam welded

shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush,

save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like Steel, Food

Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Volt-age/Hz.

Running Amps

Maximum Ambient

H x W x D

Weight (lbs.) Unit / Ship

NE040-126-12 4000 120/1/60 5.53 125°F 32” x 11.8” x 9.5” 94 / 111

NE040-126-04 4000 120/1/60 5.53 125°F 32” x 11.8” x 9.5” 94 / 111

NE040-126-4X 4000 120/1/60 5.53 125°F 32” x 11.8” x 9.5” 94 / 111

NE040-236-12 4000 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

NE040-236-04 4000 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

NE040-236-4X 4000 230/1/60 3.07 125°F 32” x 11.8” x 9.5” 99 / 116

NE040-486-12 4000 480/1/60 1.51 125°F 38” x 11.8” x 9.5” 123 / 141

NE040-486-04 4000 480/1/60 1.51 125°F 38” x 11.8” x 9.5” 123 / 141

NE040-486-4X 4000 480/1/60 1.51 125°F 38” x 11.8” x 9.5” 123 / 141

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heater System Hazardous Location Units Redundant Systems

4000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File #32252

Testing done under controlled conditions. Actual performance may vary.

2012/01 All information subject to change without notice

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save

energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage Phase

Hz.

Running Amps

Max. Ambient Temperature

Weight (lbs.) Unit / Ship

NE050-126-12 5000 120V/1/60 7.26 125°F 121 / 139

NE050-126-04 5000 120V/1/60 7.26 125°F 121 / 139

H x W x D

36” x 11.8” x 15.02”

36” x 11.8” x 15.02”

NE050-126-4X 5000 120V/1/60 7.26 125°F 36” x 11.8” x 15.02” 121 / 139

NE050-236-12 5000 230V/1/60 3.76 125°F 36” x 11.8” x 15.02” 122 / 140

NE050-236-04 5000 230V/1/60 3.76 125°F 36” x 11.8” x 15.02” 122 / 140

NE050-236-4X 5000 230V/1/60 3.76 125°F 36” x 11.8” x 15.02” 122 / 140

NE050-486-12 5000 480V/1/60 1.44 125°F 44.63” x 11.8” x 15.02” 170 / 189

NE050-486-04 5000 480V/1/60 1.44 125°F 44.63” x 11.8” x 15.02” 170 / 189

NE050-486-4X 5000 480V/1/60 1.44 125°F 44.63” x 11.8” x 15.02” 170 / 189

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heater System UL Listed Hazardous Location Redundant System

5000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File # SA32252

Testing done under controlled conditions. Actual performance may vary.

All information subject to change without notice 2012/01

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication with keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage Phase

Hz.

Running Amps

Max. Ambient Temperature

Weight (lbs.) Unit / Ship

NE060126-12 6000 120V/1/60 7.83 125°F 121 / 139

NE060126-04 6000 120V/1/60 7.83 125°F 121 / 139

H x W x D

36” x 11.8” x 15.02”

36” x 11.8” x 15.02”

NE060126-4X 6000 120V/1/60 7.83 125°F 36” x 11.8” x 15.02” 121 / 139

NE060236-12 6000 230V/1/60 4.80 125°F 36” x 11.8” x 15.02” 122 / 140

NE060236-04 6000 230V/1/60 4.80 125°F 36” x 11.8” x 15.02” 122 / 140

NE060236-4X 6000 230V/1/60 4.80 125°F 36” x 11.8” x 15.02” 122 / 140

NE060486-12 6000 480V/1/60 1.80 125°F 44.63” x 11.8” x 15.02” 170 / 189

NE060486-04 6000 480V/1/60 1.80 125°F 44.63” x 11.8” x 15.02” 170 / 189

NE060486-4X 6000 480V/1/60 1.80 125°F 44.63” x 11.8” x 15.02” 170 / 189

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Capabilities Open door kill switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System UL Listed Hazardous Location Redundant Systems

6000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File #SA32252

Testing done under controlled conditions. Actual performance may vary.

2012/01 All information subject to change without notice

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication with keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Narrow body style fits on 12” enclosure Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage Phase

Hz.

Running Amps

Max. Ambient Temperature

Weight (lbs.) Unit / Ship

NE08-126-12 8000 120V/1/60 7.83 125°F 121 / 139

NE080-126-04 8000 120V/1/60 7.83 125°F 121 / 139

H x W x D

36” x 11.8” x 15.02”

36” x 11.8” x 15.02”

NE080-126-4X 8000 120V/1/60 7.83 125°F 36” x 11.8” x 15.02” 121 / 139

NE080-236-12 8000 230V/1/60 4.80 125°F 36” x 11.8” x 15.02” 122 / 140

NE080-236-04 8000 230V/1/60 4.80 125°F 36” x 11.8” x 15.02” 122 / 140

NE080-236-4X 8000 230V/1/60 4.80 125°F 36” x 11.8” x 15.02” 122 / 140

NE080-486-12 8000 480V/1/60 1.80 125°F 44.63” x 11.8” x 15.02” 170 / 189

NE080-486-04 8000 480V/1/60 1.80 125°F 44.63” x 11.8” x 15.02” 170 / 189

NE080-486-4X 8000 480V/1/60 1.80 125°F 44.63” x 11.8” x 15.02” 170 / 189

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System UL Listed Hazardous Location Redundant System

8000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File # SA32252 2012/01

Testing done under controlled conditions. Actual performance may vary.

Informa on subject to change without no ce

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Complete elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling

capacity over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush,

save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage/Phase/Hz.

Running Amps

Max. Ambient Temperature

H x W x D

Weight (lbs.) Unit / Ship

WF060-126-12 6000 120/1/60 13.0 125°F 36.81” x 19” x 10.50” 120 / 136

WF060-236-12 6000 230/1/60 6.8 125°F 36.81” x 19” x 10.50” 145 / 161

Material

Powder coated steel

Powder coated steel

WF060-126-04 6000 Powder coated steel 120/1/60 13.0 125°F 36.81” x 19” x 10.50” 120 / 136

WF060-126-4X 6000 Stainless steel 120/1/60 13.0 125°F 36.81” x 19” x 10.50” 120 / 136

WF060-236-04 6000 Powder coated steel 230/1/60 6.8 125°F 36.81” x 19” x 10.50” 145 / 161

WF060-236-4X 6000 Stainless steel 230/1/60 6.8 125°F 36.81” x 19” x 10.50” 145 / 161

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heater System Redundant System

6000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File #SA32252 All information subject to change without notice

2012/01

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication & keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Material Voltage/Phase/Hz.

Running Amps

Max. Ambient Temperature

H x W x D

Weight (lbs.) Unit / Ship

WF081-126-12 8000 Powder coated steel 120/1/60 12.3 131°F 36.81” x 19” x 10.50” 120 / 136

WF081-126-04 8000 Powder coated steel 120/1/60 12.3 131°F 36.81” x 19” x 10.50” 120 / 136

WF081-126-4X 8000 Stainless steel 120/1/60 12.3 131°F 36.81” x 19” x 10.50” 120 / 136

WF081-236-04 8000 Powder coated steel 230/1/60 6.0 131°F 36.81” x 19” x 10.50” 145 / 161

WF081-236-4X 8000 Stainless steel 230/1/60 6.0 131°F 36.81” x 19” x 10.50” 145 / 161

WF081-236-12 8000 Powder coated steel 230/1/60 6.0 131°F 36.81” x 19” x 10.50” 145 / 161

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heater System Redundant Systems

8000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

UL File #SA32252 All information subject to change without notice 2012/01

Testing done under controlled conditions. Actual performance may vary.

0

2000

4000

6000

8000

10000

12000

14000

85 90 95 100 105 110 115 120 125 130

BT

UH

Ambient Temperature  (°F)

WF081

105

95

85

Evaporator Temperature 

(°F)

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication with keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Unit Efficiency Pressure operated blower control reduces power inrush and saves

energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity over a broad

ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush, save energy and

increase compressor life

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage Phase

Hz.

Running Amps

Max Ambient

H x W x D

Weight (lbs) Unit / Ship

HC101-126-12 10,000 120/1/60 19.40 131°F 48” x 15.86” x 15” 162 / 183

HC101-236-12 10,000 230/1/60 8.20 131°F 48” x 15.86” x 15” 165 / 186

HC101-486-12 10,000 480/1/60 3.93 131°F 56.6” x 15.86” x 15” 222 / 244

HC101-126-04 10,000 120/1/60 19.40 131°F 48” x 15.86” x 15” 162 / 183

HC101-126-4X 10,000 120/1/60 19.40 131°F 48” x 15.86” x 15” 162 / 183

HC101-236-04 10,000 230/1/60 8.20 131°F 48” x 15.86” x 15” 165 / 186

HC201-236-4X 10,000 230/1/60 8.20 131°F 48” x 15.86” x 15” 165 / 186

HC101-486-04 10,000 480/1/60 3.93 131°F 56.6” x 15.86” x 15” 222 / 244

HC101-486-4X 10,000 480/1/60 3.93 131°F 56.6” x 15.86” x 15” 222 / 244

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Package Ethernet Contact Remote Monitoring Options Integrated Enclosure Heater System Hazardous Location Package Redundant System

10,000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Performance Test Chart

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

85 90 95 100 105 110 115 120 125 130

BTU

H

Ambient Temperature

HC101

105

95

85

Evaporator Temperature 

(°F)

Testing done under controlled conditions. Actual performance may vary

UL File #SA32252 All information subject to change without notice

2012/01

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage Phase Hz.

Running Amps

Max. Ambient Temperature

H x W x D

Weight (lbs.) Unit / Ship

HC121-126-12 12,000 120/1/60 19.40 131°F 48” x 15.86” x 15.03” 162 / 183

HC121-236-12 12,000 230/1/60 8.20 131°F 48” x 15.86” x 15.03” 165 / 186

HC121-486-12 12,000 480/1/60 3.93 131°F 56.6” x 15.86” x 15.03” 222 / 244

HC121-126-04 12,000 120/1/60 19.40 131°F 48” x 15.86” x 15.03” 162 / 183

HC121-126-4X 12,000 120/1/60 19.40 131°F 48” x 15.86” x 15.03” 162 / 183

HC121-236-04 12,000 230/1/60 8.20 131°F 48” x 15.86” x 15.03” 165 / 186

HC121-236-4X 12,000 230/1/60 8.20 131°F 48” x 15.86” x 15.03” 165 / 186

HC121-486-04 12,000 480/1/60 3.93 131°F 56.6” x 15.86” x 15.03 222 / 244

HC121-486-4X 12,000 480/1/60 3.93 131°F 56.6” x 15.86” x 15.03 222 / 244

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System Hazardous Location package Redundant System

12,000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication with keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Unit Efficiency Pressure operated blower control reduces power inrush

and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power inrush,

save energy and increase compressor life

All information subject to change without notice

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

UL File # SA32252

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

22000

85 90 95 100 105 110 115 120 125 130

BTU

H

Ambient Temperature (°F) 

HC121

105

95

85

Return Air Temperature  

Testing done under controlled conditions. Actual performance may vary

2012 / 01

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour Voltage Phase/

Hz.

Run-ning Amps

Max. Ambi-ent Temper-

ature

H x W x D

Weight Unit / Ship

HC151-236-12 15,000 230/1/60 11.30 131°F 48” x 15.86” x 15.03” 170 / 191

HC151-486-12 15,000 480/1/60 5.41 131°F 56.6” x 15.86” x 15.03” 234 / 256

HC151-236-04 15,000 230/1/60 11.30 131°F 48” x 15.86” x 15.03” 170 / 191

HC151-486-04 15,000 480/1/60 5.41 131°F 56.6” x 15.86” x 15.03” 234 / 256

HC151-236-4X 15,000 230/1/60 11.30 131°F 48” x 15.86” x 15.03” 170 / 191

HC151-486-4X 15,000 480/1/60 5.41 131°F 56.6” x 15.86” x 15.03” 234 / 256

Material

Powder coated steel

Powder coated steel

Stainless steel

Powder coated steel

Powder coated steel

Stainless steel

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System Hazardous Location Packages Redundant Systems

15,000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication with keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

UL File # SA32252 All information subject to change without notice

0

5000

10000

15000

20000

25000

85 90 95 100 105 110 115 120 125 130

BTU

H

Ambient Temperature

HC151

105

95

85

Evaporator Temperature 

(°F)

Testing done under controlled conditions. Actual performance may vary

2012 / 01

Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like

Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics.

Model BTU/Hour

Voltage Phase/Hz.

Running Amps

Max. Ambient Temperature

H x W x D

Weight (lbs.) Unit / Ship

HC201-236-12 20,000 230/1/60 13.70 131°F 56.09” x 23” x 15.03” 205 / 226

HC201486-4X 20,000 480/1/60 6.56 131°F 65.7” x 23” x 15.03” 320 / 342

Material

Powder coated steel

Stainless steel

HC201-486-04 20,000 Powder coated steel 480/1/60 6.56 131°F 65.7” x 23” x 15.03” 320 / 342

HC201-486-12 20,000 Powder coated steel 480/1/60 6.56 131°F 65.7” x 23” x 15.03” 320 / 342

HC201-236-4X 20,000 Stainless steel 230/1/60 13.70 131°F 56.09” x 23” x 15.03” 205 / 226

HC201-236-04 20,000 Powder coated steel 230/1/60 13.70 131°F 56.09” x 23” x 15.03” 205 / 226

Options: Dry Contact Alarm Capabilities Open Door Kill Switch Corrosive Environment Package Low Ambient Packages Ethernet Remote Monitoring Options Integrated Enclosure Heat System Hazardous Location Package Redundant System

20,000 BTUH Indoor/Outdoor, NEMA Types 12, 4 & 4X Available

(972) 580-0200 or (888) 580-0202 • ULR: www.thermal-edge.com • Email: [email protected]

Get the Edge...Get Thermal Edge

Temperature Control Solutions for Electrical Enclosures

Digital Temperature Controller Programmable set point and temperature controls Visible Error and/or alarm messaging System status indication with keypad lockout function Modbus RTU, RS485 communication Active Condensate Evaporation System Constant elimination of condensate Increases unit efficiency by pre-cooling refrigerant Key Design Features Sloped top to allow for water runoff Designed with rigid chassis and seam welded shroud Thoughtful interior design for easy maintenance Unit Efficiency Pressure operated blower control reduces power

inrush and saves energy Highly efficient rotary compressor Fully insulated & sealed cabinet Thermal Expansion Valve to maintain cooling capacity

over a broad ambient temperature range Compressor Protection System High & Low refrigerant cutouts with fault indication Compressor anti short cycle protection Compressor run capacitors reduce power

inrush, save energy and increase compressor life

(972) 580-0200 or (888) 580-0202 • ULR: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

UL File # SA32252 All information subject to change without notice

0

5000

10000

15000

20000

25000

85 90 95 100 105 110 115 120 125 130

BTU

H

Ambient Temperature

HC201

105

95

85

Evaporator Temperature 

(°F)

Testing done under controlled conditions. Actual performance may vary

2012 / 01

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

AIR CONDITIONER ACCESSORIES

OPTIONS

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

OPEN DOOR KILL SWITCH (XKX)

Temperature Control Solutions for Electrical Enclosures

THE THERMAL EDGE OPEN DOOR KILL SWITCH WILL AUTOMATICALLY SHUT OFF YOUR ENCLOSURE AIR CONDITIONER WHEN THE DOOR OF YOUR ENCLOSURE IS OPENED. WHEN THE DOOR IS CLOSED, THE AIR CONDITIONER WILL RESUME NORMAL OPERATION.

OPTIONS

(972) 580-0200 / (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

CORROSIVE PROTECTION

Temperature Control Solutions for Electrical Enclosures

THE THERMAL EDGE PROTECTIVE COATING OPTIONS FOR COILS AND TUBING PROVIDE THE VERY BEST CORROSION PROTECTION FOR YOUR INDUSTRIAL APPLICTATIONS

Get the Edge...Get Thermal Edge

CXX PACKAGE Complete Corrosion Protection - Coated condenser and evaporator coils and passivated refrigeration tubing joints. A1 Silver Solder (45%) on all brazed fittings, passivate, prime and paint all brazed fittings. The Thermal Edge coil coating process provides a protective coating against corrosion due to acids, solvents, salt, chemicals, etc. found in corrosive environments.

BXX PACKAGE Coils Corrosion Protection - Coated condenser and evaporator coils The Thermal Edge coil coating process provides a protective coating against corrosion due to acids, solvents, salt, chemicals, etc. found in corrosive environments.

AXX PACKAGE Condenser Coil Corrosion Protection - Coated condenser coils. The Thermal Edge coil coating process provides a protective coating against corrosion due to acids, solvents, salt, chemicals, etc. found in corrosive environments.

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

OD Remote Controller Option (XXO)

OPTIONS

When having our Programmable Digital Controller on the face of our Air Conditioner does not fit your application, Thermal Edge offers the OD Package. The OD Package moves the controller into your enclosure using a 8’ cable along with a uni-versal, 16 gauge powder coated steel mounting bracket. As shown below, the air conditioner would have no openings on the face of the unit creating a secure application of our Enclosure Air Conditioner. This accessory is available on all units including NEMA Type 12, 4 and 4X. Having a smarter air conditioner is a good choice even when having an exposed Digital Controller may not be the best choice

Pictured is a NEMA Type 4X Air Conditioner with the OD remote controller option

Pictured is the application and installation of our OD remote controller option

All information subject to change without notice

Get the Edge...Get Thermal Edge

Temperature Control Solutions for Electrical Enclosures

OPTIONS

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

2” DEEP EXTENDED SURFACE AREA FILTER AND FILTER FRAME (XXM)

Temperature Control Solutions for Electrical Enclosures

Specifications subject to change without notice Get the Edge...Get Thermal Edge

Many applications and environments are excessively dusty. If your application is in a flour mill, cement plant or coal processing plant, you understand. These types of environments can create real problems for an air conditioner that by its very design requires a steady flow of reasonably clean air in order to function. The reality is that air conditioners are only as good as their air flow. Because of this, Thermal Edge offers our extended surface, 2” deep filter and filter frame assembly. Pictured below, this slide in, slide out filter frame and filter combination will increase the filter capacity 400% over our standard filters. The filter is washable and replaceable. The life expectancy is determined by the environment and the ways in which it is washed and cleaned. This deeper filter frame fits the standard holes on our NE, HC, WF and CS series units.

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

The UNIVERSAL MOUNTING PLATE allows you to mount our Enclosure Air Conditioner to your enclosure when you have used

another manufacturer’s unit.

When your Enclosure Air Conditioner has lived its useful life, you could spend more time sourcing the exact unit than simply replacing it with a Thermal Edge model. With Thermal Edge you get: Condensate boil-off built in standard on every unit All digital controller with alarming and protection circuits 12” design up to 8000 BTUH Full compressor cycling and hi/low pressure protection standard on every unit

The Thermal Edge Universal Mounting Plate Includes: Mounting hardware for air conditioner to universal plate and plate to enclosure Pre cut (NEMA Type 12) or mounted (NEMA Type 4) gasket for air conditioner to

plate and rolled gasket to install on universal plate to enclosure

OPTIONS

Specifications may change without notice

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

DIGITALLY CONTROLLED INTEGRATED HEAT PACKAGE

All information subject to change without notice

The Thermal Edge Enclosure Heat System is incorporated into the evaporator section of the air conditioner, thereby utilizing the evaporator blower for cooling or heating. Electric heating elements with thermal overloads are available in three ranges to suit most applications. The heater is controlled by our programmable, digital temperature controller. The controller has separate programmable upper and lower control limits for cooling and heating, and a programmable dead band to prevent simultaneous operation of heating and cooling. The temperature set points for cooling and heating can be set at the factory during production or field adjusted in one degree increments. The temperature set points can be protected by keypad protection. Specifications: Watts: 350, 500, 1000, or 1500 (varies by model) Capacity, BTUH: 1195, 1707 , 3413, 5120 Temperature Range: -40 to 131 degrees F Dead band: 1 to 45 degrees F

OPTIONS

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

HAZARDOUS DUTY ENCLOSURE AIR CONDITIONING SYSTEMS(XJX)

The Thermal Edge Hazardous Location units are in conformance with all requirements of UL and CUL for

Class 1, Division 2, Groups B, C, and D and will meet or exceed all of the specifications for Zone 2 T5 Rating.

SYSTEM FEATURES: Built in fully active Condensate Evaporation

Package changes condensate back to vapor Models range from 2000 to 20,000 BTUH Available in NEMA type 12, 4 and 4X

OPTIONS

Due to continuous product development specifications can change without notice

Temperature Control Solutions for Electrical Enclosures

MODEL BTU/HOUR

VOLT-AGE/

PHASE/ HZ.

NE020126 2000 120/1/60

NE020486 2000 480/1/60

NE030126 3000 120/1/60

NE030486 3000 480/1/60

NE040126 4000 120/1/60

NE040236 4000 230/1/60

NE040486 4000 480/1/60

NE050126 5000 120/1/60

NE050236 5000 230/1/60

NE050486 5000 480/1/60

NE060126 6000 120/1/60

NE060236 6000 230/1/60

NE060486 6000 480/1/60

NE080126 8000 120/1/60

NE080236 8000 230/1/60

NE080486 8000 480/1/60

HC100126 10,000 120/1/60

HC100236 10,000 230/1/60

HC100486 10,000 480/1/60

HC120126 12,000 120/1/60

HC120236 12,000 230/1/60

HC120486 12,000 480/1/60

HC155236 15,000 230/1/60

HC155486 15,000 480/1/60

HC200236 20,000 230/1/60

HC200486 20,000 480/1/60

NE020236 2000 230/1/60

NE030236 3000 230/1/60

UL LISTED

FOR HAZ LOC

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

YES

YES

YES

YES

YES

YES

YES

YES PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

PENDING

UNITS AVAILABLE WITH HAZ LOC

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

VIBRATION PACKAGE(XXG)

All information subject to change without notice

The Thermal Edge Vibration Package is designed to protect the air conditioner components from the effects of moderate vibration. Short rigid refrigerant lines connecting the compressor are replaced with shock absorbing loops to prevent work hardening and eventual fracture of the copper tubing. Fixed insulated clamps are used to restrict vibration at critical points. Pressure sensors are tied to the lines where motion might cause harmonic vibration and electrical lines are over wrapped where they might rub against hard parts.

For severe vibration in addition to the above steps taken, stainless steel flex-ible refrigerant lines are used to connect the compressor as opposed to the stand-ard copper.

Please consult your Thermal Edge Representative for mounting considerations

on severe vibration applications.

OPTIONS

The vibration package consists of the following: Fixed rubber bushings limit excess motion Stainless steel sheathed flexible hoses absorb side to side and rotary motion produced by the compressor Tubing through the boil off pan absorbs expansion and contraction Brazed connections at compressor are high temp silver solder to avoid hardening All wiring is neatly bundled & tied to prevent vibration

Temperature Control Solutions for Electrical Enclosures

All information subject to change without notice

Get the Edge…Get Thermal Edge

Thermal Edge enclosure air conditioners are listed under UL File # SA32252

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

APPLICATIONS: Extremely well suited for 1 through 6 or 7 through 18 enclosure air conditioner installations. A simple DIN Rail mounting (4 DIN) and the absence of local user interface make the XWEB300D the ideal solution for the remote connection / assistance (via modem) to the plant. Local or remote connection from a PC is made without the need for special software. Only standard web browser (Microsoft Internet Explorer® or Firefox®) software is needed; the information is displayed as Web pages. XWEB300D checks the air conditioner and, in case of malfunction alarm, it notifies the assistance center through FAX, SMS or E-mail. It allows users, via direct control, to decide to engage a local service call out only if necessary. XWEB300D can also record all data relevant to the function of the air conditioner and in-sert them into a table. • Data capture and alarm monitoring web server connectable to Dixell’s controllers with serial output or to others ModBUS-RTU compatible devices

• Structure based on Linux operating system with WEB pages • Data shown for all controller values, parameters programming and alarms • Powerful graphs showing and exporting functions in Excel® format • Calendar function to filter alarm transmissions to a particular service • Alarm sending via FAX, SMS or e-mail • Possibility to have a connection with a PDA or Smartphone • Local or remote connection to a PC with a standard browser (Microsoft Internet Explorer® or Firefox ®) for the data display and monitoring

• 8MB or 24MB internal memory to store up to 1 year data recorded with 15 min sampling time and 6 or 18 controllers • Standard communication protocol ModBUS-RTU • 15VA max power absorption

XWEB300D: ALARM AND CONTROLLING WEB SERVER

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

AIR TO AIRHEAT EXCHANGERS

AIR TO AIR HEAT EXCHANGERS HEAT PIPE TECHNOLOGY CLOSED LOOP DESIGN

THERMOSTATICALLY CONTROLLED AVAILABLE IN 120, 230, 24VDC & 48VDC

NEMA TYPE 12, 4 AND 4X UL LISTED AND UL LISTED FOR HAZARDOUS LOCATION

GET THE EDGE… GET THERMAL EDGE

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

THERMAL EDGE AIR TO AIR HEAT EXCHANGER

The Thermal Edge Air to Air Heat Exchanger is a closed loop cooling system which employs the heat pipe principle to exchange heat from an electrical enclosure to the outside. Where ambient temperatures are suitable for heat pipes, they are the most efficient method of cooling as the waste heat is the engine which drives the system. The only power requirement is to operate two circulating fans or blowers. Heat pipes have a liquid refrigerant under a partial vacuum inside sealed tubes. They operate with a phase change process which is much like that of mechanical air conditioning, but without the compressor. Each heat pipe has an evaporator section and a condenser section which are separated by a permanent baffle so as to provide a closed loop. The bottom of each heat pipe is in contact with heated air from the electrical enclosure. When the enclosure air reaches approximately 75 degrees F., the refrigerant changes to vapor phase (boils) and the vapor (steam) rises to the top of the tube which is in contact with cooler outside (ambient) air. When the outside air temperature is lower than the enclosure temperature, the refrigerant vapor gives up heat to the outside air and returns to the liquid phase. It then falls to the bottom and repeats the cycle endlessly so long as there is a negative temperature differential between the enclosure and outside. Heat pipes will not operate in reverse cycle so heat cannot be transferred from the ambient to the interior of the enclosure. Although the operation is self limiting, thermostatic control is standard to shut off the fans when not needed. The Thermal Edge design has a top-to-bottom enclosure air flow pattern with maximum separation of the inlet and outlet. This design pulls the hottest air from the top of the enclosure and returns the cooled air from the bottom of the heat pipe to the enclosure. The air flow on the ambient side is bottom in, top out, so that the hotter discharge air moves up and away rather than being recirculated. As with all of our coil systems, we use aluminum end plates and baffles which improve conduction and reduce corrosion for longer life. The center aluminum baffle, which is swaged into the heat pipe coil, provides an air tight seal between the two air systems.

Temperature Control Systems for Electrical Enclosures

GET THE EDGE… GET THERMAL EDGE

A2A SERIES AIR TO AIR HEAT EXCHANGERS

UL File # 33288 Under UL standard 1995

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Due to design and part development, all information is subject to change

A2A SERIES AIR TO AIR HEAT EXCHANGERS

All units are available in NEMA Type 12, 4 and 4X All units include thermostat except Hazardous Location units Motors have a sealed overload protector so can be used in Hazardous Location

Temperature Control Solutions for Electrical Enclosures

GET THE EDGE… GET THERMAL EDGE

Model Body Style

BTU/Hour @20°C

Watts/°C Voltage/ Hz.

Running Amps

Maximum Ambient

H x W x D (Mounting Dimensions)

A2AC040126 Compact 723 11 120 50/60 .37 160°F 16.5” x 11” x 3.5”

A2AC040236 Compact 723 11 230 50/60 .18 160°F 16.5” x 11” x 3.5”

A2AC040D24 Compact 723 11 24VDC .8 160°F 16.5” x 11” x 3.5”

A2AS040126 Slim 723 11 120 50/60 .37 160°F 21.00” X 5.6” X 11”

A2AS040236 Slim 723 11 230 50/60 .18 160°F 21.00” X 5.6” X 11”

A2AS040D24 Slim 723 11 24VDC .8 160°F 21.00” X 5.6” X 11”

A2AC080126 Compact 1446 22 120 50/60 .37 160°F 16.5” x 11” x 3.5”

A2AC080236 Compact 1446 22 230 50/60 .18 160°F 16.5” x 11” x 3.5”

A2AC080D24 Compact 1446 22 24VDC .8 160°F 16.5” x 11” x 3.5”

A2AS080126 Slim 1446 22 120 50/60 .37 160°F 21.00” X 5.6” X 11”

A2AS080236 Slim 1446 22 230 50/60 .18 160°F 21.00” X 5.6” X 11”

A2AS080D24 Slim 1446 22 24VDC .8 160°F 21.00” X 5.6” X 11”

A2AD120126 Deep 2171 33 120 50/60 .37 160°F 16.5” x 11” x 5.5”

A2AD120236 Deep 2171 33 230 50/60 .18 160°F 16.5” x 11” x 5.5”

A2AD120D24 Deep 2171 33 24VDC .8 160°F 16.5” x 11” x 5.5”

A2AS120126 Slim 2171 33 120 50/60 .37 160°F 21.00” X 5.6” X 11”

A2AS120236 Slim 2171 33 230 50/60 .18 160°F 21.00” X 5.6” X 11”

A2AS120D24 Slim 2171 33 24VDC .8 160°F 21.00” X 5.6” X 11”

A2AD160126 Deep 2894 44 120 50/60 .37 160°F 16.5” x 11” x 5.5”

A2AD160236 Deep 2894 44 230 50/60 .18 160°F 16.5” x 11” x 5.5”

A2AD160D24 Deep 2894 44 24VDC .8 160°F 16.5” x 11” x 5.5”

A2AS160126 Slim 2894 44 120 50/60 .37 160°F 21.00” X 5.6” X 11”

A2AS160236 Slim 2894 44 230 50/60 .18 160°F 21.00” X 5.6” X 11”

A2AS160D24 Slim 2894 44 24VDC .8 160°F 21.00” X 5.6” X 11”

A2AT200126 Tall 3666 55 120 50/60 .47 160°F 29” x 13.88 x 5.5”

A2AT200236 Tall 3666 55 230 50/60 .243 160°F 29” x 13.88 x 5.5”

A2AT200D24 Tall 3666 55 24VDC 1.94 160°F 29” x 13.88 x 5.5”

A2AT260126 Tall 4887 71.6 120 50/60 .47 160°F 29” x 13.88 x 5.5”

A2AT260236 Tall 4887 71.6 230 50/60 .243 160°F 29” x 13.88 x 5.5”

A2AT260D24 Tall 4887 71.6 24VDC 1.94 160°F 29” x 13.88 x 5.5”

A2AC040D48 Compact 723 11 48VDC TBD 160°F 16.5” x 11” x 3.5”

A2AS040D48 Slim 723 11 48VDC TBD 160°F 21.00” X 5.6” X 11”

A2AC080D48 Compact 1446 22 48VDC TBD 160°F 16.5” x 11” x 3.5”

A2AS080D48 Slim 1446 22 48VDC TBD 160°F 21.00” X 5.6” X 11”

A2AD120D48 Deep 2171 33 48VDC TBD 160°F 16.5” x 11” x 5.5”

A2AS120D48 Slim 2171 33 48VDC TBD 160°F 21.00” X 5.6” X 11”

A2AD160D48 Deep 2894 44 48VDC TBD 160°F 16.5” x 11” x 5.5”

A2AS160D48 Slim 2894 44 48VDC TBD 160°F 21.00” X 5.6” X 11”

A2AT200D48 Tall 3666 55 48VDC TBD 160°F 29” x 13.88 x 5.5”

A2AT260D48 Tall 4887 71.6 48VDC TBD 160°F 29” x 13.88 x 5.5”

FACT:  FILTERED FANS INTRODUCE DIRT AND CONTAMINATION INTO EVERY ELECTRICAL ENCLOSURE USING THEM FACT:  DRIVES AND PLCS DO NOT LIKE DIRT, DUST AND CONTAMINATION FACT:  FILTERED FANS CAN NEVER PRODUCE A TRUE CLOSED LOOP COOLING SOLUTION FACT:  NO MATTER HOW EFFECTIVE YOUR FILTER IS, DIRT AND PARTICULATES WILL ENTER YOUR ENCLOSURE 

CONSIDER A BETTER SOLUTION ‐ AIR TO AIR HEAT EXCHANGER:    ALWAYS CLOSED LOOP  LOW COST AND MAINTENANCE FREE  EASIER TO MOUNT ON ONLY ONE SIDE OF YOUR ENCLOSURE  ENERGY EFFICIENT, USING NO MORE POWER THAN A FILTERED FAN SYSTEM  FILTER FREE, SO NO DIMINISHED COOLING CAPACITY.  AIR TO AIR HEAT EXCHANGERS ARE AVAILABLE IN NEMA TYPES 12, 4 AND 4X 

In this image, a standard installation shows where the dirt and particulate will enter the enclosure and be pulled in by the fans on your drives and devices.   Filters or not,  contamination is invited in by this open loop approach. 

In this image, a standard installation       demonstrates the closed loop condition maintained by the Air to Air Heat        Exchanger.   Cool air inlet and outlet vents are completely covered by the heat exchanger.  This provides NEMA Type 12, 4 or 4X.    

Components are Failing inside electrical enclosures when using Filtered Fan Packages 

We are happy and qualified to assist you in sizing your application to remove heat issues in your electrical enclosures.   Call us today at (972) 580‐0202 or (888) 580‐0202 

Thermal Edge Inc. • Irving, Texas • (972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com

GET THE EDGE… GET THERMAL EDGE

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

GET THE EDGE… GET THERMAL EDGE Due to design and part development, all information is subject to change

DEEP SERIES

COMPACT SERIES

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

SLIM SERIES

TALL SERIES

GET THE EDGE… GET THERMAL EDGE Due to design and part development, all information is subject to change

TALL SERIES

SLIM SERIES

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

ENCLOSURE ACCESSORIES

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

• Compact fan heater in PTC Technology • Heating power adjusts to ambient temperature • Integrated adjustable thermostat and control light • DIN rail mountable

Enclosure Heaters

PTC Fan Heater Model CR 027 400 - 650W

Part # Voltage Capacity Max Current

TEI-EH400CR236 220-240 VAC 400W (50Hz) 11A

TEI-EH550CR236 220-240 VAC 550W (50Hz) 13A

TEI-EH550CR120 100-120 VAC 550W (60Hz) 14A

TEI-EH650CR120 100-120 VAC 650W (60Hz) 15A

Axial Fan FPM

20

26

20

26

Thermostat Range

0 - 60°C

0 - 60°C

32 - 140°F

32 - 140°F

Weight

2.0 lbs.

2.4 lbs

2.0 lbs.

2.4 lbs

Heating Element PTC-semiconductor/resistor, self-regulating with changing ambient temperature

Overheat Protection Built in temperature limiter in case of fan failure

Function Control Light LED

Housing Plastic, UL94V-0

Dimensions 6.5”H x 3.94”W x 5”D

Connection 2 pole terminal, AWG 14 max.

Mounting Clip for 35 mm DIN rail

Protection Class II (double insulated)

Protection Type IP 20

Information subject to change without

Temperature Control Solutions for Electrical Enclosures

Heating power 950W, Setting range 0 to 140°F Heating element High performance Heat sink Extruded aluminum profile Overheat protec- Built-in temperature limiter Axial fan Ball bearing with service life 50,000 at 77°F

Air flow, free 94 CFM Connection 2-pole terminal, AWG 14 max. With integral

Wiring compart- Plastic, UL94V-0, black Dimensions 6.6” x 5.7” x 3.9”

• Compact foot–mounted fan heater • Built in overheat protection • Integrated adjustable thermostat

or fixed hygrostat • Double insulated plastic housing

Enclosure Heaters

Foot-Mount High Performance

950W Fan Heater

Weight 3.1 lbs. Mounting M5 screws (not included) Position Horizontal Operating temp. 32°F to 140°F

Storage temp. -49°F to 158°F Protection class II (double isolated)

Protection type IP20

Approvals VDE-230 VAC models only, UL-120 and 230 VAC models

Part # Operating Voltage Heating Capacity

Setting Range

TEI-EH950CR230 AC 230 V, 50-60 Hz 950W 0-60°C

TEI-EH950CR120 AC 120 V, 50-60 Hz 950W 32-140°F

Information subject to change without notice

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Heating power 950W, Setting range 0 to 140°F Heating element PTC resistor-temperature limiting Heat sink Extruded aluminum profile Overheat protection Built-in temperature limiter Axial fan Ball bearing with service life 50,000 at 77°F (25°C) Air flow, free blowing 94 CFM Connection 2-pole terminal, AWG 16 max. With integral strain relief

Wiring compartment Plastic, UL94V-0, black Dimensions 6.6” x 5.7” x 4.7”

• Compact foot–mounted fan heater • Built in overheat protection • Integrated adjustable thermostat

or fixed hygrostat • Double insulated plastic housing

Enclosure Heaters

Foot-Mount High Performance

1200W Fan Heater

Weight 2.6 lbs. Mounting M5 screws (not included) Position Horizontal Operating temp. 32°F to 140°F

Storage temp. -49°F to 158°F Protection class II (double isolated)

Protection type IP20 Approvals VDE-230 VAC models only, UL-120

and 230 VAC models

Part Number Operating Volt-age

Heating Capacity

Setting Range

TEI-EH1200CR230 AC 230 V, 50-60 Hz 1200W 0-60°C

TEI-EH1200CR120 AC 120 V, 50-60 Hz 1200W 32-140°F

Information subject to change without notice

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

• Compact heater in PTC Technology • Heating power adjusts to ambient temperature • DIN rail mountable • Push connectors for quick and easy wiring • UL and CE approved

Enclosure Heaters

PTC Heater Model HG 140

15-150W

Part # Capacity @ 68°F Ambient

Maximum Current (Inrush)

L Dimension

Weight

TEI-EH15HG1224 15W 1.5A 2.6” .66 lbs

TEI-EH30HG1224 30W 3.0A 2.6” .66 lbs

TEI-EH45HG1224 45W 3.5A 2.6” .66 lbs

TEI-EH60HG1224 60W 2.5A 5.5” 1.10 lbs

TEI-EH75HG1224 75W 4.0A 5.5” 1.10 lbs

TEI-EH100HG1224 100W 4.5A 5.5” 1.10 lbs

TEI-EH150HG1224 150W 9.0A 8.7” 1.76 lbs

Operating voltage 110 - 250 VAC

Heating Element PTC resistor, self-regulating

Heating body Anodized extruded aluminum

Connection Push-type terminals for stranded and solid wire 3 x AWG 20 - 16

Mounting Clip for 35 mm DIN rail

Protection Class I, test voltage 1600V

Protection Type IP 20

Agency approvals UL, VDE

Information subject to change without

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

• Small compact size fan heater • Built in overheat protection • DIN rail mountable

Enclosure Heaters

Compact 100-400W FAN HEATER

HVL031

Capacity 120 VAC P/N 230 VAC P/N

100W TEI-EH100HVL120 TEI-EH100HVL230

150W TEI-EH150HVL120 TEI-EH150HVL230

200W TEI-EH200HVL120 TEI-EH200HVL230

300W TEI-EH300HVL120 TEI-EH300HVL230

400W TEI-EH400HVL120 TEI-EH400HVL230

Weight

1.3

1.3

2.0

2.0

2.0

Heating Element Resistance type cartridge heater

Heat Sink Die cast aluminum, glass bead finish

Overheat Protection Built in temperature limiter

Air exit temperature Approximately 113°F

Wiring Compartment Plastic, UL94V-0

Connection (heater) 3 pole terminal, AWG 14 max.

Connection (fan) 2 pole terminal, AWG 14 max.

Mounting Clip for 35 mm DIN rail

Protection Class I (grounded)

Protection Type IP 20

Agency Approvals UL (all), VDE (230 VAC only)

Information subject to change without notice

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

• Compact design • Wide adjustment rang • Available with °F or °C scale • Color coded temperature dials • DIN rail mountable

Enclosure Heaters & Controls

KT 011 Thermostat

Part # Contact Type Scale

TEI-KT-011-NCF Normally Closed 30 - 140°F

TEI-KT-011-NOF Normally Open 30 - 140°F

TEI-KT-011-NCC Normally Closed 0 - 60°C

TEI-KT-011-NOC Normally Open 0 - 60°C

Sensor Element Thermostatic bi-metal

Maximum Tolerance +/- 7.2°F (4K)

Switching Difference 12.6°F +/- 5.4°F

Service Life 100,000 cycles

Switching Capacity (max load)

15A resistive / 2A inductive @120 VAC

10A resistive / 2A inductive @ 250 VAC

Minimum Load 20mA (all voltages)

EMI/EMC Compliance EN 55014-1-2, EN 61000-3-2, EN 61000-3-3

Connections 2 pole terminal for AWG 14 max

Mounting Clip for 35mm DIN rail

Dimensions (H x W x D)

2.4” x 1.3” x 1.7”

Housing Plastic, UL94V-0

Weight 1.4 oz

Protection Type IP 20

Operating Temperature -4° to 176°F

Storage Temperature -49° to 176°

Agency Approvals UL, CSA

Information subject to change without notice

Thermostat “NC” (normally closed): Thermostat opens at temperature rise.

Comes with a red temperature dial. Thermostat “NO” (normally open): Thermostat closes at temperature rise.

Comes with a blue temperature dial.

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

• Two thermostats in one unit - One Normally Open & One Normally Closed - Or, two Normally Open • Each with wide adjustable temperature range • Available with °F or °C scale • DIN rail mountable

Enclosure Heaters & Controls

Dual Thermostat ZR 011

Sensor Element Thermostatic bi-metal

Maximum tolerance + / - 7.2°F

Switching Difference (hysteresis) 12.6°F+/- 5.4°F

Switching Capacity NC: 10A resisteive/2A inductive @ 250VAC

NO: 5A resistive/2A inductive @ 250VAC

Dimensions (H x W x D) 2.6” x 2.0” x 1.8”

Housing Plastic, UL94V-0

Weight 3.2 oz

Protection Type IP 20

Operating / Storage Temperature -4° to 176°F

Agency Approvals UL, CSA

Minimum Load 20 mA

EMI/EMC compliance EN55014-1-2, EN61000-3-2, EN61000-3-3

Mounting Clip for 35mm DIN rail

Information subject to change without

Part Number NC (red) NO (blue)

TEI-ZR32140-ORF 32 - 140°F 32 - 140°F

TEI-ZR060-ORC 0 - 60°C 0 - 60°C

TEI-ZR060-CRC 0 - 60°C 0 - 60°C

TEI-ZR32140-CRF 32 - 140°F 32 - 140°F

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

FILTERED FANS & RAIN SHROUDS

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

FILTER FAN PACKAGES Injection Molded Plastic

CFM Free Flow

Voltage/Hz Temperature Range

RPM Type Part Number Type

80 115V, 50/60 -40F to 158F 2900 1 PFFP080-01-120 3R

80 230 / 50/60 -40F to 158F 2900 1 PFFP080-01-230 3R

80 24VDC -40F to 158F 2200 1 PFFP080-01-24 3R

131 115V, 50/60 -40F to 158F 3300 1 PFFP100-01-120 3R

131 230 / 50/60 -40F to 158F 3300 1 PFFP100-01-230 3R

140 24 VDC -40F to 158F 3000 1 PFFP100-01-24 3R

300 115V, 50/60 -40F to 158F 3300 1 PFFP200-01-120 3R

300 230 / 50/60 -40F to 158F 3300 1 PFFP200-01-230 3R

300 24 VDC -40F to 158F 3900 1 PFFP200-01-24 3R

390 115V, 50/60 -40F to 158F 3800 1 PFFP390-01-120 3R

390 230 / 50/60 -40F to 158F 3300 1 PFFP390-01-230 3R

390 24 VDC -40F to 158F 3000 1 PFFP390-01-24 3R

750 115V, 50/60 -40F to 158F 2200 1 PFFP500-01-120 3R

750 230 / 50/60 -40F to 158F 2200 1 PFFP500-01-230 3R

Rated Amps

.11

.06

.19

0.17/0.18

0.1/0.11

0.23

0.35/0.40

0.20/0.22

2.1

0.51/0.54

0.30/0.33

0.69

0.50/0.58

0.25/0.30

Part Number

PFFP080-3R-120

PFFP080-3R-230

PFFP080-3R-24

PFFP100-3R-120

PFFP100-3R-230

PFFP100-3R-24

PFFP200-3R-120

PFFP200-3R-230

PFFP200-3R-24

PFFP390-3R-120

PFFP390-3R-230

PFFP390-3R-24

PFFP500-3R-120

PFFP500-3R-230

Mount with Hardware OR mount using Integrated Clips up to 14 gauge Filter media is Electrostatic Polypropylene

All Kits Include Integrated Gaskets and Mounting Template

Efficient, Quiet Ball Bearing Fans

Accessory Thermostat Kit

UL File # E319601

Temperature Control Solutions for Electrical Enclosures

Model PFFP 100 131 CFM

Model PFFP 500 750 CFM

Model PFFP 200 300 CFM

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Information subject to change without notice

Model PFFP 390 393 CFM

Model PFFP 080 80 CFM

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

FILTER FAN PACKAGES Powder Coated and Stainless Steel

Model CFM Free Flow

Voltage/Hz Rated Amps

Temp Range RPM

TEI-MFFP-100-120 131 115 50/60 0.17/0.18 -40F to +158 F 3300

TEI-MFFP-100-230 131 230 50/60 0.10/0.11 -40F to +158 F 3300

TEI-MFFP-100-D24 140 24 VDC 0.23 -40F to +158 F 3000

TEI-MFFP-200-120 300 115 50/60 0.35/0.40 -40F to +158 F 3300

TEI-MFFP-200-230 300 230 50/60 0.20/0.22 -40F to +158 F 3300

TEI-MFFP-200-D24 300 24 VDC 2.1 -40F to +158 F 3900

TEI-MFFP-500-120 750 115 50/60 0.50/0.58 -40F to +158 F 2200

TEI-MFFP-500-230 750 230 50/60 0.25/.030 -40F to +158 F 2200

TEI-SFFP-200-120 300 115 50/60 0.35/0.40 -40F to +158 F 3300

TEI-SFFP-200-230 300 230 50/60 0.20/0.22 -40F to +158 F 3300

TEI-SFFP-200-D24 300 24 VDC 2.1 -40F to +158 F 3900

16 Gauge Powder Coated Mild Steel Efficient, Quiet Ball Bearing Fans Filter Media is Electrostatic Polypropylene Thermostat available as accessory

Available in 304 Stainless Steel All Kits Include Gaskets, Hardware and Templates Includes 8’ Cord with a Plug

ANSI 61 Powder Coated Mild Steel 304 Stainless Steel

TEI-MFFP Series

TEI-SFFP Series

UL File # E319601

Information subject to change without notice

Temperature Control Solutions for Electrical Enclosures

Accessories • NEMA 3R Rain Shrouds • Aluminum Framed Washable Filters • Thermostat for control of Filtered Fan

Package Operation • Enclosure Open Door Kill Switch

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 •www.thermal-edge.com • [email protected]

Thermal Edge Filtered Fan Package ELECTROSTATIC POLYPROPYLENE FILTER MEDIA

Our unique 1/4” corrugated polypropylene filtration media features an electrostatic charge that assists in filtering dirt, dust and other irritating pollutants from the air. This industrial filter media is a dense, 3 layer, waffle weave configuration, which enhances the filtration abilities and creates a rigid and durable electrostatic air filter. Additionally, the Thermal Edge air filtration media can be rinsed or vacuum cleaned, and will not degrade over time as foam does.

Media PermaCool Polypropylene

Weave type 3 - D waffle corrugated

U.L. classification Class 2

Yarn diameter 10 mil

Yarn count (warp/fill) 65/74

Media thickness .25”

Media weight 10.1 oz per square yard

Temperature rating Operating 180° F, Melting 325°F

Initial resistance 0.04 inches w.g.

Average arrestance efficiency 63%

Dust holding capacity 100 Grams

Get the Edge...Get Thermal Edge

ACTUAL MATERIAL DISPLAYING MULTILAYERED MATERIAL

Filtered Fan Package Filter Media

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

FILTER FAN PACKAGES Rain Shrouds

Specifics 16 Gauge Powder Coated Mild Steel Maintains NEMA 3R Include Gaskets On All Three Edges Kits Include All Mounting Hardware &

Template

P/N 100-FFP-3R

P/N 500-FFP-3R

P/N 200-FFP-3R Installation Shrouds come 2 to a kit and are sized to fit neatly over your openings and fans.

Application Our Fan Shroud Kits are designed to keep the elements out of your enclosure while allowing the free air movement from your filtered fan packages.

Temperature Control Solutions for Electrical Enclosures

TITLE3R SHROUD INSTALLATION

OVER FILTER FAN PACKAGES

SIZEA

DWG NO3R SHROUD INSTALLATION

REV

FILE: FFP, 3R+MFFP Installation.dft

SCALE: WEIGHT: SHEET 1 OF 1

3R SHROUD INSTALLATIONOVER FILTER FAN PACKAGES

1. BEFORE INSTALLING, VERIFY"CUTOUT" DIMENSIONS FORACCURACY.

2. USING "CUTOUT" TEMPLATELOCATE, DRILL AND CUT TWOCUTOUTS FOR BEST AIRCIRCULATION.

3. INSTALL FANS AND FILTERPLATES PER THEIR OWNINDIVIDUAL INSTRUCTIONS.

4. 3R RAIN SHROUD IS FIT OVERFILTER FAN ASSEMBLY ANDFASTENED FROM INSIDE.

TITLE3R SHROUD INSTALLATION

OVER FILTER FAN PACKAGES

SIZEA

DWG NO3R SHROUD INSTALLATION

REV

FILE: 3R, Fan Installation, UL Type 3.dft

SCALE: WEIGHT: SHEET 2 OF 2

2. BEFORE INSTALLING AND BEFORE USING TEMPLATE AS AN OVERLAY, VERIFY TEMPLATE "CUTOUT" DIMENSIONS FOR ACCURACY AS PRINT PROPERTIES MAY VARY AND ACCURACY CAN NOT BE ASSURED. 3. USING "CUTOUT" TEMPLATE LOCATE PER (A) INSTRUCTION # 1 AND (B)FOR BEST AIR CIRCULATION, DRILL AND CUT A CUTOUT FOR EACH SIDE OF THE FAN KIT AND EACH 3R SHROUD. 4. INSTALL FANS AND FILTER PLATES PER THEIR OWN INDIVIDUAL INSTRUCTION SHEET(S). (SEE FAN ASSEMBLY AS SOME FAN COMPONENTS MAY REQUIRE INSTALLATION FROM EITHER INSIDE OR OUTSIDE ENCLOSURE). 5. 3R RAIN SHROUD IS FIT OVER FILTER FAN ASSEMBLY PER THE TEMPLATE AND FASTENED FROM INSIDE THE ENCLOSURE. (SEE FAN ASSEMBLY AS SOME FAN COMPONENTS MAY REQUIRE INSTALLATION FROM EITHER INSIDE OR OUTSIDE ENCLOSURE). RELATED RESOURCES:

A. TEMPLATE FILE NAMES a. CUTOUT_3R100 MFFP, C size.pdf (also .dwg file extension) b. CUTOUT_3R200 MFFP, C size.pdf (also .dwg file extension) c. CUTOUT_3R500 MFFP, C size.pdf (also .dwg file extension) d. CUTOUT_MFFP100, A size.pdf (also .dwg file extension) e. CUTOUT_MFFP200, B size.pdf (also .dwg file extension) f. CUTOUT_MFFP500, C size.pdf (also .dwg file extension) g. CUTOUT_PFFP080, A-size.pdf (also .dwg file extension) h. CUTOUT_PFFP100, A-size.pdf (also .dwg file extension) i. CUTOUT_PFFP200, C size.pdf (also .dwg file extension) j. CUTOUT_PFFP500, C size.pdf (also .dwg file extension)

B. FAN INSTALLATION INSTRUCTIONS FILE NAMES a. MFFP Kit Installation.pdf b. PFFP Kit Installation.pdf

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

PACKAGED SYSTEMS Enclosures with Air Conditioners

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

PACKAGED SYSTEMS ELECTRICAL ENCLOSURES WITH UL LISTED AIR CONDITIONERS 

UL LISTED NEMA TYPE 12, 4 OR 4X ELECTRICAL ENCLOSURE 

PRE CUT AND FINISHED EDGES TO ACCOMMODATE THE AIR CONDITIONER 

APPROPRIATELY SIZED UL LISTED AIR CONDITIONER  

ALL MOUNTING HARDWARE AND GASKETING 

 

Get the Edge...Get Thermal Edge

UL Type 12 Floor Standing Enclosure, w/interior panel. 10 gauge carbon steel, Key-locking, pad-lockable handle, interior white & exterior ANSI 61 gray, continuous hinge doors. Includes 10 gauge. sub panel painted white

Part Number x = A/C chassis style Dimensions H x W x D

606012-12FDTEx A, B, C, D, E, F, G, H, J, K 60 x 60 x 12

606016-12FDTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 60 x 60 x 16

726012-12FDTEx A, B, C, D, E, F, G, H, J, K 72 x 60 x 12

726016-12FDTEx A, B, C, D,, E, F, G, H, J, K, L, M, N, P 72 x 60 x 16

727212-12FDTEx A, B, C, D, E, F, G, H, J, K 72 x 72 x 12

727216-12FDTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 72 x 16

727224-12FDTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R, S, T 72 x 72 x 24

UL Type 12 Free Standing Enclosure, w/interior panel. 12 gauge carbon steel, key-locking, pad-lockable handle, interior white & exterior ANSI 61 gray, continuous hinge doors. Includes 12 gauge sub panel for single door and 10 gauge sub panel for double door. All panels are painted white

Part number Doors x = A/C chassis style Dimensions H x W x D

723618-12FSTEx Single A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 36 x 18

723624-12FSTEx Single A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 36 x 24

724818-12FSDTEx Double A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 48 x 18

724824-12FSDTEx Double A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 48 x 24

726018-12FSDTEx Double A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 60 x 18

726024-12FSDTEx Double A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 60 x 24

727218-12FSDTEx Double A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 72 x 18

727224-12FSDTEx Double A, B, C, D, E, F, G, H, J, L, M, N, P 72 x 72 x 24

UL Type 4 Floor Standing Enclosure, w/interior panel. 10 gauge carbon steel, pad-lockable, easy release door clamps, interior white & exterior ANSI 61 gray, 12" legs welded, continuous hinge doors. Includes 10 gauge sub panel painted white

Part number X = A/C chassis style Dimensions H x W x D

626012-4FDTEx A, B, C, D, E, F, G, H, J, K 60 x 60 x 12

746012-4FDTEx A, B, C, D, E, F, G, H, J, K 60 x 60 x 12

747224-4FDTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R, S, T 72 x 60 x 24

thermal [email protected] (972) 580-0200 or (888) 580-0202

thermal [email protected] (972) 580-0200 or (888) 580-0202

UL Type 4X Floor Standing Enclosure, w/interior panel. 12 gauge 304 stainless steel, pad-lockable, easy release door clamps, interior white & exterior ANSI 61 gray, 12" legs welded, continuous hinge doors. Includes 10 gauge sub panel painted white

UL Type 4 Free Standing Enclosure, w/interior panel. 12 gauge carbon steel, pad-lockable, easy release door clamps, interior white & exterior ANSI 61 gray, continuous hinge doors. Includes 10 gauge Sub panel painted white.

UL Type 4X Free Standing Enclosure, w/interior panel. 12 gauge 304 stainless steel, pad-lockable, easy release door clamps, interior white & exterior ANSI 61 gray, continuous hinge doors. Includes 12 gauge sub panel painted white.

Part number X = A/C chassis style Dimensions H x W x D

723118-4FSTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 31 x 18

723718-4FSTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 37 x 18

723724-4FTSTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 37 x 24

Part number X = A/C chassis style Dimensions H X W x D

626012-4XSFDTEx A, B, C, D, E, F, G, H, J, K 62 x 60 x 12

746012-4XSFDTEx A, B, C, D, E, F, G, H, J, K 74 x 60 x 12

747224-4XSFDTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P, Q, R, S, T 74 x 72 x 24

Part number X = A/C chassis style Dimensions H x W x D

723118-4XSFSTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 31 x 18

723718-4XSFSTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 37 x 18

723724-4XSFSTEx A, B, C, D, E, F, G, H, J, K, L, M, N, P 72 x 37 x 24

1751 Hurd Drive Irving, Texas 75038

A I R C O N D I T I O N E R O P T I O N S

(972) 580-0200 or

(888) 580-0202

Get the Edge...Get Thermal Edge

Email: [email protected] Web: www.thermal-edge.com

Protective Coil Coating to protect from corrosion caused by a salt or chemical

environment Enclosure door kill switch Integrated Heat Packages to provide total temperature control for your enclosure

not just from the heat of summer but from the cold of winter Dry Contact Options to allow the use of alarms, lights and notifications External Heat Control to allow for customers to use an externally mounted heater

in their enclosure Vibration Package allows for enclosure cooling on cranes, moving vehicles or other

difficult locations. These systems are available in two levels 2” Deep Extended Filter Media for applications like flour, cement or coal when a

standard filter will load to quickly OD Remote Controller Option to place our digital controller inside the electrical

enclosure when the environment requires a more secure setting UL Listed for Hazardous location, Class 1, Div 2, Groups B, C, D

The Legendary Green Bay Packers Coach

Vince Lombardi said: “Winning is not a sometime

thing; it’s an all-the-time thing. You don’t win once in a while, you don’t do things right once in a while, you do

them right all the time. Winning is a habit.

Unfortunately, so is losing.”

S T A N D A R D O N E V E R Y T H E R M A L E D G E A I R C O N D I T I O N E R

Condensate evaporation package Fully programmable digital controller Thermal expansion valve Full product line available in NEMA Types 12, 4 & 4X UL Listed under Standard 484, file number SA32252 On/off switch as mandated by UL Standard 484 Proudly manufactured in the U.S.A.

Inventory on Hand

Customer Service answering your calls

A website that is easy to navigate AND solutions that are easy to find

Equipment tested to perform and built to last

Units designed with our customer’s applications and environments in mind

Systems engineered to maintain lower running amps and higher efficiency

Features and Accessories designed to solve critical applications as in Corrosive or Hazardous Environments

NOTE: AIR CONDITIONERS ARE SHIPPED SEPARATELY FROM ENCLOSURES

2010_09

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

GENERAL INFORMATION

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

Temperature Control Solutions for Electrical Enclosures

THE THERMAL EDGE PLEDGE:

WE PLEDGE TO ONLY PROMISE SHIP DATES THAT WE CAN MEET. WE PLEDGE THAT ON THE OCCASION THAT WE CANNOT MEET A SHIP DATE,

THE CUSTOMER WILL BE THE FIRST PERSON WE CALL WE PLEDGE TO TOLERATE NOTHING LESS THAN ZERO DEFECTS ON EVERY

PRODUCT WE MAKE. WE PLEDGE TO EMBRACE NEW TECHNOLOGIES AND FRESH IDEAS

FOR MANUFACTURING, EVEN IF THEY ARE NOT OUR OWN. WE PLEDGE TO PROVIDE OUR PEOPLE WITH THE VERY BEST TOOLS AND

PROCESSES IN ORDER TO ENABLE THEM TO BE THEIR VERY BEST. WE PLEDGE TO ALWAYS VALUE OUR CUSTOMER’S TIME BY ALWAYS TAKING THEIR

CALL AND NEVER USING VOICE MAIL AS A FORM OF COMMUNICATION. WE PLEDGE TO RESPOND TO OUR CUSTOMER’S EMAIL CORRESPONDENCE AND

REQUESTS IMMEDIATELY AND WITHOUT DELAY. WE PLEDGE TO SPEAK WITH OUR CUSTOMERS PERSONALLY, HONESTLY AND IN A

STRAIGHT FORWARD MANNER. WE PLEDGE TO LISTEN TO OUR CUSTOMERS WHEN THEY DESCRIBE THEIR

APPLICATION SO THAT WE WILL ALWAYS DIAGNOSE THEIR APPLICATION CORRECTLY THE FIRST TIME.

WE PLEDGE TO GUARANTEE EVERY APPLICATION OUR CUSTOMERS BRING US. THIS MEANS THAT WHEN WE MAKE A RECOMMENDATION BASED ON COMPLETE INFORMATION PROVIDED, WE WILL GUARANTEE THE PERFORMANCE OF OUR UNIT.

WE PLEDGE TO ALWAYS PLAN, DREAM AND DEVELOP THE MOST TECHNOLOGICALLY ADVANCED SYSTEMS OF OUR TIME.

WE PLEDGE TO ALWAYS BE WORKING ON THE NEXT GENERATION OF OUR PRODUCTS BRINGING IN NEW INNOVATION AND DESIGNS.

USER MANUAL ON EVERY THERMAL EDGE ENCLOSURE AIR CONDITIONER

Get the Edge…Get Thermal Edge

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

N T E U QR ,

. B J 15, 2011, T E QR

/

U *, . ‐ .

E ‐

.

*You must download a QR reader app (free) for your phone to use this feature

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • [email protected]

Temperature Control Solutions for Electrical Enclosures

BTU/H CALCULATOR OPTIONS 

We have two options for using our BTU/H calculator.    1.  You can use the calculator on the web page or download  it to your desktop at      

www.thermal‐edge.com/calculator.  2.  If you are not at your desk and want to have the calculator in your hand, go to  www.thermal‐edge.com/calculator and select the icon to use our mobile BTU/H calculator  application on any IPhone or Android device. 

 

WITH BOTH OF THESE OPTIONS, YOU GET THE THERMAL EDGE CALCULATOR TO SIZE YOUR TEMPERATURE CONTROL APPLICATION.  ENCLOSURE AIR CONDITIONERS,                               AIR‐TO‐AIR HEAT EXCHANGERS OR FILTER AND FAN PACKAGES...THERMAL EDGE  Get the Edge...Get Thermal Edge 

MOBIL BTU/H CALCULATOR  DESKTOP AND/OR DOWNLOADABLE BTU/H CALCULATOR 

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

CONDENSATE MANAGEMENT

All information subject to change without notice

Get the Edge…Get Thermal Edge

Thermal Edge Condensate Control is accomplished by routing refrigerant hot gas through our condensate boil off pan. The pan is located ahead of the condenser in the hottest point in the refrigerant system where the hot gas temperature is 180° F to 260° F. Condensate is evaporated and the vapor is discharged though the condenser blower to the environment. Additionally, this condensate evaporation helps to pre-cool the hot gas, lowering the running amps and making our industrial air conditioner more efficient. By utilizing this pre-cool method, we lower the overall use of energy. This condensate boil off pan has enough water storage capacity to dehydrate the air in your equipment enclosure and vent it off without overflow so long as the enclosure doors are closed. In the event that the enclosure will remain open, Thermal Edge does supply an Emergency Overflow Fitting on all of our units. Use of this Fitting is only for extreme open-door applications and should not be utilized in typical or even heavy applications. Please Contact Thermal Edge for more information on use of this feature.

STANDARD ON ALL THERMAL EDGE AIR CONDITIONING SYSTEMS

UL File #SA32252

Temperature Control Solutions for Electrical Enclosures

All information subject to change without notice

Get the Edge…Get Thermal Edge

Enclosure Air Conditioner is UL File # SA32252

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

Temperature Control Solutions for Electrical Enclosures

Fully programmable Built in alarms and alerts Will operate heating & cooling Standard on every unit Ethernet system available

DIGITAL, PROGRAMMABLE CONTROLLER

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected]

All information subject to change without notice Get the Edge…Get Thermal Edge

ADVANTAGES OF USING A THERMAL EXPANSION VALVE All phase change refrigerant systems require an expansion device which controls the flow of refrigerant in the evaporator. Two principal types of control are used: Thermal Expansion Valves or Capillary Tubes. Thermal Expansion Valves balance and modulate the refrigerant flow to the heat load by sensing the temperature of the refrigerant leaving the evaporator. There are three major advantages to this refrigerant control method. 1. Maximum efficiency over a wide temperature and load range 2. Improved refrigerant return to the compressor assures better cooling at high tempera-

tures and reduces the possibility of liquid slugging which can destroy the compressor. 3. Variations in refrigerant charge, particularly smaller units, are less critical

Alternately, fixed expansion devices, such as Capillary Tubes, are fixed; working

at one preset level and have no ability to compensate for load changes. They are more commonly used in unchanging environmental temperatures such as refrigerators and freezers. Since most refrigerators are in a temperature controlled space and have limited temperature set point, they work just fine. Due to their simplicity, capillary tubes are very inexpensive. (However, this rarely translates into a cost saving for the purchaser of indus-trial enclosure air conditioning.)

Variations of capacity over the ambient temperature range of 80o F to 131oF can

cause a performance loss of 85% with a cap tube system. A well tuned expansion valve system will lose less than on half this amount, while maintaining better compressor tem-perature control. That’s why Thermal Edge Inc. uses Thermal Expansion Valves. In your demanding environment, you need enclosure cooling that you can depend on, regard-less of temperature changes through out the work day or seasonal year.

Temperature Control Solutions for Electrical Enclosures

(972) 580-0200 or (888) 580-0202 •www.thermal-edge.com

In order to be compliant with UL Standard 484, all Thermal Edge Enclosure Air Conditioners will include the safety feature of an On/Off switch on the backside of our units facing into the electrical enclosure. Please see the drawing below for the location of this easy to use safety feature.

1751 Hurd Drive ● Irving, Texas 75038 ● (972) 580-0200 ● (888) 580-0202 ● Fax (972) 580-0277

URL: www.thermal-edge.com ● Email: [email protected]

TERMS AND CONDITIONS

ACKNOWLEDGEMENT All orders will be faxed an acknowledgement and terms and conditions clause with an estimated shipment date.  PRICES All prices quoted are F.O.B. factory and do not include any sales, excise or use tax, either Federal or State.  Buyer assumes responsibility/liability for payment of all state or municipal taxes applicable to use or resale of products purchased herein.  Title and risk of loss to equipment pass to the buyer upon delivery to carrier.  Not responsible for typographical errors.  PRICES ARE SUBJECT TO CHANGE WITHOUT NOTICE.  TERMS AND PAYMENT POLICIES 1%, 10 days, Net, Thirty (30) days to those customers of known and acceptable financial standing.  A credit application MUST be completed and returned to Thermal Edge, Inc. for open terms. Otherwise, orders must be accompanied by cash, credit card or will be shipped COD.  We accept Visa, MasterCard and American Express.  Wire transfer of funds will also be accepted.  For all sales outside the United States, wire transfer prior to release of materials will be required. Contact Sales Office for details.    SPECIAL ORDERS All special orders must be prepaid and are not subject to cancellation or return.  No work will be started until payment is received.    RESTOCKING AND RETURNS Merchandise must not be returned without prior approval and return authorization number, which will be given or withheld at our sole discretion.  All returned merchandise must be sent freight PREPAID to the following address: Thermal Edge, INC. ATTN: RMA #  1751 HURD DRIVE STE 111 IRVING, TX 75038  If the merchandise is in a new, unused condition and in its original carton with all the original packaging and prior approval will be given a credit allowance amounting to the original selling prices less the restocking charge as follows: a) Within 60 days of the invoice date and not a special order – 25% of applicable selling price. b) Within 61‐ 120 days of the invoice date and not a special order – 30% of applicable selling price. c) Within 121 – 180 days of the invoice date and not a special order – 35% of applicable selling price. d) Beyond 180 days of the invoice date are subject to discretion of the Business Manager. Shipments of returned merchandise sent collect will not be accepted.  If there is any repair work of any nature required at the time of receiving inspection at our plant there will be an additional charge for repair work over and above the applicable restocking charge.  Returns must be banded to a pallet and marked “Must remain upright and banded to the pallet”. Any returns not banded to a pallet and are not marked as such, will be closely evaluated before any credit will be issued.  Merchandise that has been “customer modified” or has any special finishes applied cannot be returned for credit. 

1751 Hurd Drive ● Irving, Texas 75038 ● (972) 580-0200 ● (888) 580-0202 ● Fax (972) 580-0277

URL: www.thermal-edge.com ● Email: [email protected]

 WARRANTY All products are warranted for a period of one (1) year from invoice date.  Any warranty repair work must be issued a return authorization number PRIOR to return.    CLAIMS In the event of shortage or damage, notify the carrier FIRST as well as Thermal Edge, Inc. immediately upon receipt.  We are not responsible for damage occurring in transit, but will gladly render any assistance necessary to pursue your claim against the transportation company.  Merchandise must be inspected for concealed damage within 15 days of receipt.  ORDER CANCELLATION A charge of 15% of the net price will be applied on any cancellation of a formally acknowledged order. If modifications, specifically ordered by the customer, are being made of the cancelled merchandise, the cancellation charge will also include such modifications made up to the date of cancellation.  Any order cancelled after product is shipped will be subject to restocking charges and all shipping costs.  ORDER QUANTITY CHANGE In the event that a large quantity order is placed that requires special requests to our vendors for the necessary material to complete the order and the order is reduced for any reason after an order acknowledgement has been sent, there will be a charge.  This charge will be based on the quantity, specialty and the requested delivery dates of the original order and the cost from our vendors to stop or reduce the special request.  Any large order discount will be re‐evaluated upon quantity change.  DESIGN CHANGES Thermal Edge, Inc. reserves the right to make design, hardware, engineering and packaging changes, which do not interfere with the use for which such products were designed and manufactured.  SHIPPING All shipments are routed motor freight via our carriers unless otherwise specified by the customer. Our products are packaged in heavy duty cartons and are banded to a pallet.  Most items are one per carton unless otherwise stated.  CONTINGENCIES All orders received are contingent upon accidents, strikes and other causes beyond our control.  Shipments are subject to Accounting and Business Office approval.  MINIMUM ORDER A minimum order of $50.00 is required unless otherwise cleared through the Accounting and Business Office. 

(972) 580-0200 or (888) 580-0202 • www.thermal-edge.com • Email: [email protected] [email protected]

PRICE LIST 2012

(972) 580-0200 or (888) 580-0202 • Web: www.thermal-edge.com • Email: [email protected]

All information subject to change without notice

Get the Edge…Get Thermal Edge

Warranty Information Thermal Edge products are warranted to be free of defects in workmanship, materials and compo-nents. The warranty period applies from date of shipment for one year. The above warranty applies when the equipment is operated under the following conditions: Ambient temperature not in excess of performance rating in normal atmosphere or as stated on product nameplate Voltage variation no greater than ± 10% from nameplate rating Frequency variation no greater than ± 3Hz from nameplate rating Maximum cooling load no higher than air conditioner nameplate rating Waiting five minutes before restarting air conditioner after intentional or accidental shutoff Compliance to all other installation, maintenance and operating instructions, as supplied Thermal Edge cannot assume responsibility for misapplication of its products or the erroneous se-lection of an inappropriate product by a non-authorized Thermal Edge representative. Our applica-tions engineers will gladly assist in the selection of the proper product provided all required details of the application are furnished. Thermal Edge assumes no liability beyond the repair or replacement of its own product. This War-ranty does not cover: Labor or reimbursement of labor for evaluation, removal, installation, repair, or cost of any war-ranted part, except at the Thermal Edge factory in Dallas, Texas Use of equipment for other than its designed purpose or operating conditions Operation in harsh, oily, corrosive or other abnormal environmental conditions, without the proper filtration, sealing, protective coatings and/or weather protection Damage to hermetic system resulting from continuous operation with dirty or clogged air filters or improper or negligent maintenance Use of refrigerant other than designated Customer modification or abuse Shipping damage or other accident Repair or service by unauthorized personnel. Cracked or broken hermetic tubing or brazed joints caused by shipping damage or mishandling are not covered under the Warranty. Claims for shipping damage are the responsibility of the Con-signee. Timely claims must be filed with the freight carrier. The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local electrical and safety codes, as well as the 2008 National Electric Code (NEC) and OSHA.

THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANT-ABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS THER-MAL EDGE RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.

Terms and Conditions: Payment Terms: 1% 10, net 30 Shipping Terms: FOB Destination, pre-pay and add to invoice Return Policy: 25% Restocking fee on all stock goods. No return on units with options.

Temperature Control Solutions for Electrical Enclosures

Capacity Voltage Part Number Price Part Number Price Part Number 304 316

1000 BTUH 120V/1/60 NE‐010‐126‐12 12 $1,738  NE‐010‐126‐04 4 $1,786  NE‐010‐126‐4X 4X $2,848  $3,275 

1000 BTUH 230V/1/60 NE‐010‐236‐12 12 $1,770  NE‐010‐236‐04 4 $1,818  NE‐010‐236‐4X 4X $2,880  $3,312 

1000 BTUH 120V/1/60 CS‐011‐126‐12 12 $1,863  CS‐011‐126‐04 4 $1,911  CS‐011‐126‐4X 4X $2,935  $3,410 

1500 BTUH 120V/1/60 NE‐015‐126‐12 12 $1,834  NE‐015‐126‐04 4 $1,882  NE‐015‐126‐4X 4X $2,952  $3,395 

1500 BTUH 230V/1/60 NE‐015‐236‐12 12 $1,922  NE‐015‐236‐04 4 $1,970  NE‐015‐236‐4X 4X $2,984  $3,432 

2000 BTUH 120V/1/60 CS‐020‐126‐12 12 $2,093  CS‐020‐126‐04 4 $2,141  CS‐020‐126‐4X 4X $3,165  $3,640 

2000 BTUH 230V/1/60 CS‐020‐236‐12 12 $2,136  CS‐020‐236‐04 4 $2,184  CS‐020‐236‐4X 4X $3,197  $3,677 

2000 BTUH 120V/1/60 NE‐020‐126‐12 12 $1,968  NE‐020‐126‐04 4 $2,016  NE‐020‐126‐4X 4X $3,037  $3,492 

2000 BTUH 230V/1/60 NE‐020‐236‐12 12 $2,001  NE‐020‐236‐04 4 $2,049  NE‐020‐236‐4X 4X $3,069  $3,529 

2000 BTUH 480V/1/60 NE‐020‐486‐12 12 $2,503  NE‐020‐486‐04 4 $2,551  NE‐020‐486‐4X 4X $3,572  $4,107 

3000 BTUH 120V/1/60 NE‐030‐126‐12 12 $1,984  NE‐030‐126‐04 4 $2,032  NE‐030‐126‐4X 4X $3,114  $3,581 

3000 BTUH 230V/1/60 NE‐030‐236‐12 12 $2,016  NE‐030‐236‐04 4 $2,064  NE‐030‐236‐4X 4X $3,146  $3,618 

3000 BTUH 480V/1/60 NE‐030‐486‐12 12 $2,519  NE‐030‐486‐04 4 $2,567  NE‐030‐486‐4X 4X $3,649  $4,196 

4000 BTUH 120V/1/60 NE‐040‐126‐12 12 $2,034  NE‐040‐126‐04 4 $2,082  NE‐040‐126‐4X 4X $3,249  $3,736 

4000 BTUH 230V/1/60 NE‐040‐236‐12 12 $2,066  NE‐040‐236‐04 4 $2,114  NE‐040‐236‐4X 4X $3,281  $3,773 

4000 BTUH 480V/1/60 NE‐040‐486‐12 12 $2,569  NE‐040‐486‐04 4 $2,617  NE‐040‐486‐4X 4X $3,784  $4,351 

5000 BTUH 120V/1/60 NE‐050‐126‐12 12 $2,344  NE‐050‐126‐04 4 $2,392  NE‐050‐126‐4X 4X $3,534  $4,064 

5000 BTUH 230V/1/60 NE‐050‐236‐12 12 $2,558  NE‐050‐236‐04 4 $2,606  NE‐050‐236‐4X 4X $3,566  $4,101 

5000 BTUH 480V/1/60 NE‐050‐486‐12 12 $3,276  NE‐050‐486‐04 4 $3,324  NE‐050‐486‐4X 4X $4,068  $5,536 

6000 BTUH 120V/1/60 NE‐060‐126‐12 12 $2,634  NE‐060‐126‐04 4 $2,682  NE‐060‐126‐4X 4X $3,776  $4,343 

6000 BTUH 230V/1/60 NE‐060‐236‐12 12 $2,666  NE‐060‐236‐04 4 $2,714  NE‐060‐236‐4X 4X $3,808  $4,380 

6000 BTUH 480V/1/60 NE‐060‐486‐12 12 $3,361  NE‐060‐486‐04 4 $3,409  NE‐060‐486‐4X 4X $4,311  $5,604 

6000 BTUH 120V/1/60 WF‐060‐126‐12 12 $2,660  WF‐060‐126‐04 4 $2,708  WF‐060‐126‐4X 4X $3,776  $4,523 

6000 BTUH 230/1/60 WF‐060‐236‐12 12 $2,844  WF‐060‐236‐04 4 $2,892  WF‐060‐236‐4X 4X $3,808  $4,679 

8000 BTUH 120V/1/60 NE‐080‐126‐12 12 $2,677  NE‐080‐126‐04 4 $2,725  NE‐080‐126‐4X 4X $3,961  $4,555 

8000 BTUH 230V/1/60 NE‐080‐236‐12 12 $2,709  NE‐080‐236‐04 4 $2,757  NE‐080‐236‐4X 4X $3,993  $4,592 

8000 BTUH 480V/1/60 NE‐080‐486‐12 12 $3,404  NE‐080‐486‐04 4 $3,452  NE‐080‐486‐4X 4X $4,496  $5,816 

8000 BTUH 120V/1/60 WF‐080‐126‐12 12 $2,751  WF‐080‐126‐04 4 $2,799  WF‐080‐126‐4X 4X $3,961  $4,618 

8000 BTUH 230V/1/60 WF‐080‐236‐12 12 $2,904  WF‐080‐236‐04 4 $2,952  WF‐080‐236‐4X 4X $3,993  $4,771 

10000 BTUH 120V/1/60 HC‐101‐126‐12 12 $3,983  HC‐101‐126‐04 4 $4,031  HC‐101‐126‐4X 4X $5,421  $6,234 

10000 BTUH 230V/1/60 HC‐101‐236‐12 12 $4,015  HC‐101‐236‐04 4 $4,063  HC‐101‐236‐4X 4X $5,453  $6,271 

10000 BTUH 480V/1/60 HC‐101‐486‐12 12 $4,518  HC‐101‐486‐04 4 $4,566  HC‐101‐486‐4X 4X $5,956  $7,399 

12000 BTUH 120V/1/60 HC‐121‐126‐12 12 $4,045  HC‐121‐126‐04 4 $4,093  HC‐121‐126‐4X 4X $5,483  $6,305 

12000 BTUH 230V/1/60 HC‐121‐236‐12 12 $4,077  HC‐121‐236‐04 4 $4,125  HC‐121‐236‐4X 4X $5,515  $6,342 

12000 BTUH 480V/1/60 HC‐121‐486‐12 12 $4,580  HC‐121‐486‐04 4 $4,628  HC‐121‐486‐4X 4X $6,018  $7,462 

15000 BTUH 230V/1/60 HC‐151‐236‐12 12 $4,398  HC‐151‐236‐04 4 $4,446  HC‐151‐236‐4X 4X $5,943  $6,834 

15000 BTUH 480V/1/60 HC‐151‐486‐12 12 $5,008  HC‐151‐486‐04 4 $5,056  HC‐151‐486‐4X 4X $6,446  $7,866 

20000 BTUH 230V/1/60 HC‐201‐236‐12 12 $5,521  HC‐201‐236‐04 4 $5,569  HC‐201‐236‐4X 4X $9,073  $10,434 

20000 BTUH 480V/1/60 HC‐201‐486‐12 12 $6,484  HC‐201‐486‐04 4 $6,532  HC‐201‐486‐4X 4X $9,608  $11,049 

2012_01

Enclosure Air Conditioners

AIR CONDITIONER OPTIONS PRICE LIST 1/4/2012

Option Code Description List Price

AXX CPA - Ambient Package (Condenser Coil Only) $196BXX CPT - Total Package (Condenser Coil & Evaporator Coil) $335CXX CPC - Option BXX with passivated refrigeration tubing joints $415

2XX Integrated 350 Watt Heater $173DXX Integrated 500 Watt Heater $173EXX Integrated 1000 Watt Heater $375FXX Integrated 1500 Watt Heater $727

HXX Low Ambient Package - Standard (20°F) $132HXZ Low Ambient Package - Custom Call For Pricing

ELECTRICAL OPTIONSDry Contact Options (with 8 ft. Wire)XAX Normally Open $193XBX Normally Closed $193XCX Normally Open & Closed $360XEX External Heat Output $113XFX Hard Start Kit $175XGX High Ambient /Normally Closed Dry Contact Call For PricingSpecial ProgrammingXDX Celsius Controller Programming $25XHX Special Controller Programming $202 minimum + $25/unitXIX High Ambient Call For PricingXJX Hazardous Location for HC Series (Class 1, Div 2, Groups B, C, D) $4,800XJX Hazardous Location for NE Series (Class 1, Div 2, Groups B, C, D) $4,200XKX Open Door Kill Switch $154XPX Adjustable Temperature Probe (12 ft. Wire) $27XRX Redundant System $660 + Price of 2 ACsXSX ModBus-RTU, RS 485 (Required for XWEB) $102XUX Ethernet/IP Contoller Output $1,797

CUSTOM OPTIONSXXA Custom Paint Color Call For PricingXXB 316 SS Shroud - 1,000/1,500 BTUH See A/C PricingXXC 316 SS Shroud - 2,000/3,000/4,000 BTUH See A/C PricingXXD 316 SS Shroud - 5,000 BTUH & Larger See A/C PricingXXE Custom Paint/316 Stainless Steel Call For PricingXXF Flaw (Scratch & Dent) Call For PricingXXG Vibration Package $252XXH Security Filter Frame (CS020, NEMA 12/4) $10XXH Security Filter Frame (NE2/3/4, NEMA12/4) $11XXH Security Filter Frame (NE5/6/8, NEMA 12/4) $13XXH Security Filter Frame (HC101/121/151/201, NEMA 12/4) $19XXH Security Filter Frame (WF NEMA 12/4) $14XXH Security Filter Frame (CS020, NEMA 4X-304SS) $10XXH Security Filter Frame (NE2/3/4, NEMA 4X-304SS) $11XXH Security Filter Frame (NE5/6/8, NEMA 4X-304SS) $14XXH Security Filter Frame (HC101/121/151/201, NEMA 4X-304SS) $20XXH Security Filter Frame (WF, NEMA 4X-304SS) $15XXI 316 Stainless Steel Security Filter Frame (CS020) $64XXI 316 Stainless Steel Security Filter Frame (NE2/3/4) $62XXI 316 Stainless Steel Security Filter Frame (NE5/6/8) $68XXI 316 Stainless Steel Security Filter Frame (HC101/121/151/201) $79XXI 316 Stainless Steel Security Filter Frame (WF) $85

OUTDOOR OPTIONS

Integrated Heat Options

Low Ambient Package

Corrosion Packages

AIR CONDITIONER OPTIONS PRICE LIST 1/4/2012

Option Code Description List Price

XXJ 316 Stainless Steel Sliding Filter Frame & 2" Pleated Filter (CS020) $137XXJ 316 Stainless Steel Sliding Filter Frame & 2" Pleated Filter (NE2/3/4) $131XXJ 316 Stainless Steel Sliding Filter Frame & 2" Pleated Filter (NE5/6/8) $143XXJ 316 Stainless Steel Sliding Filter Frame & 2" Pleated Filter (HC101/121/151/201) $157XXJ 316 Stainless Steel Sliding Filter Frame & 2" Pleated Filter (WF) $165XXK Filter Hood for NE020/030/040 $286XXK Filter Hood for NE050/060/080 $304XXK Filter Hood for CS020 $275XXK Filter Hood for HC101/121/151/201 $365

XXM Sliding Filter Frame & 2" Pleated Filter (CS020) $126XXM Sliding Filter Frame & 2" Pleated Filter (NE020/030/040) $120XXM Sliding Filter Frame & 2" Pleated Filter (NE050/060/080) $132XXM Sliding Filter Frame & 2" Pleated Filter (HC101/121/151/201) $146XXM Sliding Filter Frame & 2" Pleated Filter (WF) $158XXM Sliding Filter Frame & 2" Pleated Filter (CS020, NEMA 4X-304SS) $130XXM Sliding Filter Frame & 2" Pleated Filter (NE2/3/4, NEMA 4X-304SS) $124XXM Sliding Filter Frame & 2" Pleated Filter (NE5/6/8, NEMA 4X-304SS) $136XXM Sliding Filter Frame & 2" Pleated Filter (HC101/121/151/201, NEMA 4X-304SS) $150XXM Sliding Filter Frame & 2" Pleated Filter (WF, NEMA 4X-304SS) $159XXO Remote Controller Kit (OD Option) $288XXS Louvered Security Cover for Flat Filter (CS020, NEMA 12/4) $54XXS Louvered Security Cover for Flat Filter (NE2/3/4, NEMA12/4) $52XXS Louvered Security Cover for Flat Filter (NE5/6/8, NEMA 12/4) $57XXS Louvered Security Cover for Flat Filter (HC101/121/151/201, NEMA 12/4) $68XXS Louvered Security Cover for Flat Filter (WF, NEMA 12/4) $74XXS Louvered Security Cover for Flat Filter (CS020, NEMA 4X-304SS) $57XXS Louvered Security Cover for Flat Filter (NE2/3/4, NEMA 4X-304SS) $55XXS Louvered Security Cover for Flat Filter (NE5/6/8, NEMA 4X-304SS) $61XXS Louvered Security Cover for Flat Filter (HC101/121/151/201, NEMA 4X-304SS) $72XXS Louvered Security Cover for Flat Filter (WF, NEMA 4X-304SS) $78XX6 Louvered Security Cover & 2" Pleated Filter (CS020, NEMA 12/4) $174XX6 Louvered Security Cover & 2" Pleated Filter (NE2/3/4, NEMA12/4) $167XX6 Louvered Security Cover & 2" Pleated Filter (NE5/6/8, NEMA 12/4) $183XX6 Louvered Security Cover & 2" Pleated Filter (HC101/121/151/201, NEMA 12/4) $218XX6 Louvered Security Cover & 2" Pleated Filter (WF, NEMA 12/4) $236XX6 Louvered Security Cover & 2" Pleated Filter (CS020, NEMA 4X-304SS) $187XX6 Louvered Security Cover & 2" Pleated Filter (NE2/3/4, NEMA 4X-304SS) $179XX6 Louvered Security Cover & 2" Pleated Filter (NE5/6/8, NEMA 4X-304SS) $197XX6 Louvered Security Cover & 2" Pleated Filter (HC101/121/151/201, NEMA 4X-304SS) $252XX6 Louvered Security Cover & 2" Pleated Filter (WF, NEMA 4X-304SS) $272XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (CS020, NEMA 12/4) $174XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (NE2/3/4, NEMA12/4) $167XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (NE5/6/8, NEMA 12/4) $183XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (HC101/121/151/201, NEMA 12/4) $218XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (WF, NEMA 12/4) $236XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (CS020, NEMA 4X-304SS) $187XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (NE2/3/4, NEMA 4X-304SS) $179XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (NE5/6/8, NEMA 4X-304SS) $197XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (HC101/121/151/201, NEMA 4X-304SS) $252XX7 Louvered Sliding Filter Cover & 2" Pleated Filter (WF, NEMA 4X-304SS) $272

UNIVERSAL MOUNTING PLATES Net Price

Call for PN CS, NE & WF Series $175Call for PN HC Series $225

Replacement Filters for Air Conditioners

A/C Unit P/N Description Qty Price

Standard Filter

NE010 44200 7.5" W x 9" H  Exp. alum, 250 micron, 60% efficiency 12 162$     

NE015 44200 7.5" W x 9" H Exp. alum, 250 micron, 60% efficiency 12 162$     

CS020 44201 9" W x 11" H     Exp. alum, 250 micron, 60% efficiency 12 179$     

NE020 44202 7.3" W x 11.3" H Exp. alum, 250 micron, 60% efficiency 12 166$     

NE030 44202 7.3" W x 11.3" H Exp. alum, 250 micron, 60% efficiency 12 166$     

NE040 44202 7.3" W x 11.3" H Exp. alum, 250 micron, 60% efficiency 12 166$     

NE050 44203 10.3" W x 16.3" H Exp. alum, 250 micron, 60% efficiency 12 257$     

NE060 44203 10.3" W x 16.3" H Exp. alum, 250 micron, 60% efficiency 12 257$     

NE080 44203 10.3" W x 16.3" H Exp. alum, 250 micron, 60% efficiency 12 257$     

HC100 44204 14" W  x 24" H Exp. alum, 250 micron, 60% efficiency 12 335$     

HC120 44204 14" W  x 24" H Exp. alum, 250 micron, 60% efficiency 12 335$     

HC155 44204 14" W  x 24" H Exp. alum, 250 micron, 60% efficiency 12 335$     

HC200 44204 14" W  x 24" H Exp. alum, 250 micron, 60% efficiency 12 335$     

WF060 44205 17" W  x 17" H Exp. alum, 250 micron, 60% efficiency 12 290$     

WF080 44205 17" W  x 17" H Exp. alum, 250 micron, 60% efficiency 12 290$     

2" Pleated Filt

CS020 44250 9" W x 11" H 304 SS mesh, 250 micron, 94% efficiency 4 432$     

NE020 44251 7.3" W x 11.3" H 304 SS mesh, 250 micron, 94% efficiency 4 427$     

NE030 44251 7.3" W x 11.3" H 304 SS mesh, 250 micron, 94% efficiency 4 427$     

NE040 44251 7.3" W x 11.3" H 304 SS mesh, 250 micron, 94% efficiency 4 427$     

NE050 44252 10.3" W x 16.3" H 304 SS mesh, 250 micron, 94% efficiency 4 535$     

NE060 44252 10.3" W x 16.3" H 304 SS mesh, 250 micron, 94% efficiency 4 535$     

NE080 44252 10.3" W x 16.3" H 304 SS mesh, 250 micron, 94% efficiency 4 535$     

WF060 44253 17" W x 17" H 304 SS mesh, 250 micron, 94% efficiency 4 763$     

WF080 44253 17" W x 17" H 304 SS mesh, 250 micron, 94% efficiency 4 763$     

HC‐100 44254 14" W x 24" H 304 SS mesh, 250 micron, 94% efficiency 4 819$     

HC‐120 44254 14" W x 24" H 304 SS mesh, 250 micron, 94% efficiency 4 819$     

HC‐155 44254 14" W x 24" H 304 SS mesh, 250 micron, 94% efficiency 4 819$     

HC‐200 44254 14" W x 24" H 304 SS mesh, 250 micron, 94% efficiency 4 819$     

HC100‐120 OLD 44206 Flat Filter  Exp. alum, 250 micron, 60% efficiency, (13"W x 19"H) 12 292$     

HC100‐120 OLD 44255 2" Pleated 304 SS mesh, 250 micron, 94% efficiency, (13"W x 19"H) 4 627$     

2012_01

Due to continuous development, our information is subject to change without notice

Air to Air Heat Exchangers

Watts/°C Watts/°F Model  NEMA Price Model  NEMA Price Model  NEMA Price

11 6 A2AC04012012 12 $1,117 A2AC04012004 4 $1,228 A2AC0401204X 4X $1,658

11 6 A2AC04023012 12 $1,157 A2AC04023004 4 $1,268 A2AC0402304X 4X $1,698

11 6 A2AC040D2412 12 $1,169 A2AC040D2404 4 $1,280 A2AC040D244X 4X $1,710

11 6 A2AC040D4812 12 $1,180 A2AC040D4804 4 $1,291 A2AC040D484X 4X $1,721

11 6 A2AS04012012 12 $1,237 A2AS04012004 4 $1,348 A2AS0401204X 4X $1,778

11 6 A2AS04023012 12 $1,277 A2AS04023004 4 $1,388 A2AS0402304X 4X $1,818

11 6 A2AS040D2412 12 $1,289 A2AS040D2404 4 $1,399 A2AS040D244X 4X $1,830

11 6 A2AS040D4812 12 $1,299 A2AS040D4804 4 $1,410 A2AS040D484X 4X $1,841

22 12 A2AC08012012 12 $1,193 A2AC08012004 4 $1,312 A2AC0801204X 4X $1,771

22 12 A2AC08023012 12 $1,233 A2AC08023004 4 $1,352 A2AC0802304X 4X $1,811

22 12 A2AC080D2412 12 $1,245 A2AC080D2404 4 $1,364 A2AC080D244X 4X $1,823

22 12 A2AC080D4812 12 $1,256 A2AC080D4804 4 $1,375 A2AC080D484X 4X $1,834

22 12 A2AS08012012 12 $1,313 A2AS08012004 4 $1,432 A2AS0801204X 4X $1,891

22 12 A2AS08023012 12 $1,353 A2AS08023004 4 $1,472 A2AS0802304X 4X $1,931

22 12 A2AS080D2412 12 $1,365 A2AS080D2404 4 $1,484 A2AS080D244X 4X $1,943

22 12 A2AS080D4812 12 $1,376 A2AS080D4804 4 $1,495 A2AS080D484X 4X $1,954

33 18 A2AD12012012 12 $1,238 A2AD12012004 4 $1,362 A2AD1201204X 4X $1,837

33 18 A2AD12023012 12 $1,278 A2AD12023004 4 $1,402 A2AD1202304X 4X $1,877

33 18 A2AD120D2412 12 $1,290 A2AD120D2412 4 $1,414 A2AD120D244X 4X $1,889

33 18 A2AD120D4812 12 $1,301 A2AD120D4804 4 $1,425 A2AD120D484X 4X $1,900

33 18 A2AS12012012 12 $1,358 A2AS12012004 4 $1,482 A2AS1201204X 4X $1,957

33 18 A2AS12023012 12 $1,398 A2AS12023004 4 $1,522 A2AS1202304X 4X $1,997

33 18 A2AS120D2412 12 $1,410 A2AS120D2404 4 $1,534 A2AS120D244X 4X $2,002

33 18 A2AS120D4812 12 $1,421 A2AS120D4804 4 $1,545 A2AS120D484X 4X $2,020

44 24 A2AD16012012 12 $1,299 A2AD16012004 4 $1,429 A2AD1601204X 4X $1,929

44 24 A2AD16023012 12 $1,339 A2AD16023004 4 $1,469 A2AD1602304X 4X $1,969

44 24 A2AD160D2412 12 $1,351 A2AD160D2404 4 $1,481 A2AD160D244X 4X $1,981

44 24 A2AD160D4812 12 $1,362 A2AD160D4804 4 $1,492 A2AD160D484X 4X $1,992

44 24 A2AS16012012 12 $1,419 A2AS16012004 4 $1,549 A2AS1601204X 4X $2,049

44 24 A2AS16023012 12 $1,459 A2AS16023004 4 $1,589 A2AS1602304X 4X $2,089

44 24 A2AS160D2412 12 $1,471 A2AS160D2404 4 $1,601 A2AS160D244X 4X $2,101

44 24 A2AS160D4812 12 $1,482 A2AS160D4804 4 $1,612 A2AS160D484X 4X $2,112

55 31 A2AT20012012 12 $1,653 A2AT20012004 4 $1,819 A2AT2001204X 4X $2,455

55 31 A2AT20023012 12 $1,693 A2AT20023004 4 $1,859 A2AT2002304X 4X $2,495

55 31 A2AT200D2412 12 $1,705 A2AT200D2404 4 $1,871 A2AT200D244X 4X $2,507

55 31 A2AT200D4812 12 $1,716 A2AT200D4804 4 $1,882 A2AT200D484X 4X $2,518

71.6 40 A2AT26012012 12 $1,822 A2AT26012004 4 $2,070 A2AT2601204X 4X $2,795

71.6 40 A2AT26023012 12 $1,862 A2AT26023004 4 $2,110 A2AT2602304X 4X $2,835

71.6 40 A2AT260D2412 12 $1,874 A2AT260D2404 4 $2,122 A2AT260D244X 4X $2,847

71.6 40 A2AT260D4812 12 $1,885 A2AT260D4804 4 $2,133 A2AT260D484X 4X $2,858

Coated condenser coil and evaporator coil (XBX) $199

$600

Due to continous development, information is subject to change without notice

2012/01

Hazardous Location Option Class 1, Div 2, Groups A,B,C,D (XJX)

Enclosure List Prices

Model Number List Price

606012‐12FDTEx 3,176$ 606016‐12FDTEx 3,312$ 726012‐12FDTEx 3,652$ 726016‐12FDTEx 3,803$ 727212‐12FDTEx 4,111$ 727216‐12FDTEx 4,306$ 727224‐12FDTEx 4,753$ KEY

723618‐12FSTEx 2,571$ A NE010, NE015 120/230V Cutout, Right Side

723624‐12FSTEx 2,789$ B

724818‐12FSDTEx 3,781$ C NE020, NE030, NE040 120/230V Cutout, Right Side

724824‐12FSDTEx 4,096$ D NE020, NE030, NE040 120/230V Cutout, Left Side

726018‐12FSDTEx 4,281$ E NE020, NE030, NE040 480V Cutout, Right Side

726024‐12FSDTEx 4,630$ F NE020, NE030, NE040 480V Cutout, Left Side

727218‐12FSDTEx 4,776$ G NE050, NE060, NE080 120/230V Cutout, Right Side

727224‐12FSDTEx 5,081$ H NE050, NE060, NE080 120/230V Cutout, Left Side

626012‐4FDTEx 4,014$ J NE050, NE060, NE080 480V Cutout, Right Side

746012‐4FDTEx 4,493$ K NE050, NE060, NE080 480V Cutout, Left Side

747224‐4FDTEx 5,698$ L HC100, HC120, HC155 120/230V Cutout, Right Side

723118‐4FSTEx 3,173$ M HC100, HC120, HC155 120/230V Cutout, Left Side

723718‐4FSTEx 3,474$ N HC100, HC120, HC155 480V Cutout, Right Side

723724‐4FSTEx 3,593$ P HC100, HC120, HC155 480V Cutout, Left Side

626012‐4XSFDTEx 11,084$ Q HC180, HC200, HC240120/230V Cutout, Right Side

746012‐4XSFDTEx 12,738$ R HC180, HC200, HC240 120/230V Cutout, Left Side

747224‐4XSFDTEx 17,430$ S HC180, HC200, HC240 480V Cutout, Right Side

723118‐4XSFSTEx 9,403$ T HC180, HC200, HC240 480V Cutout, Left Side

723718‐4XSFSTEx 10,265$ 723724‐4XSFSTEx 10,507$

Note:  Enclosures and air conditioners are shipped separately

2010_07

                 Thermal Edge Inc. | Irving, Texas | (972) 580‐0200 or (888) 580‐0202 | www.thermal‐edge.com

Type 4X Floor 

Standing 

Enclosure

Type 4X Free 

Standing 

Enclosure

Price includes holes & cut‐out for a pre‐determined air conditioning unit and a pre‐installed back 

panel.  Specify the air conditioner model and left or right side, when viewing the enclosure from the 

front, using the chart above.  Replace the "x" at the end of the enclosure model number with the KEY 

letter.                                                                                                                                                                 

Example  Type 12 Floor Standing Enclosure, 60"H x 60"W x 12"D, for an NE040 230V air conditioner 

mounted on the left side of the enclosure:  606012‐12FDTED.

Type 12 Floor 

Standing 

Enclosure

Air Conditioner Model Cutout and Position

Type 12 Free 

Standing 

Enclosure

NE010, NE015 120/230V Cutout, Left Side

Type 4 Floor 

Standing 

Enclosure

Type 4 Free 

Standing 

Enclosure

MASTER PART NUMBERS - ENCLOSURES

- TE

A NE010, NE015 Cutout, Right Side

B NE010, NE015 Cutout, Left Side

C NE020, NE030, NE040 Cutout, Right Side

D NE020, NE030, NE040 Cutout, Left Side

E NE020, NE030, NE040 480v Cutout, Right Side

F NE020, NE030, NE040 480vvCutout, Left Side

G NE050, NE060, NE080 Cutout, Right Side

H NE050, NE060, NE080 Cutout, Left Side

J NE050, NE060, NE080 480V Cutout, Right Side

K NE050, NE060, NE080 480V Cutout, Left Side

L HC100, HC120, HC155 Cutout, Right Side

M HC100, HC120, HC155 Cutout, Left Side

N HC100, HC120, HC155 480V Cutout, Right Side

P HC100, HC120, HC155 480V Cutout, Left Side

Q HC200, HC240 Cutout, Right Side

R HC200, HC240 Cutout, Left Side

S HC200, HC240 480V Cutout, Right Side

T HC200, HC240 480V Cutout, Left Side

SingleD Double

Number of Characters (Max)6 3 2 1 1

Door Style

X X X X X

Air Conditioner Cutout & Posiiton on Enclosure

F Floor StandingFS Free Standing

12 Nema 124 Nema 4

4XS Nema 4x

H W D606012 60" 60" 12"606016 60" 60" 16"626012 62" 60" 12"723118 72" 31" 18"723618 72" 36" 18"723624 72" 36" 24"723718 72" 37" 18"723724 72" 37" 24"724818 72" 48" 18"724824 72" 48" 24"726012 72" 60" 12"726016 72" 60" 16"726018 72" 60" 18"726024 72" 60" 24"727212 72" 72" 12"727216 72" 72" 16"727218 72" 72" 18"727224 72" 72" 24"746012 74" 60" 12"747224 74" 72" 24"

Enclosure Style

NEMA Types

Enclosure Size (Inside Dimensions)

Filtered Fan Packages and Options

POWDER COATED 16 GAUGE MILD STEEL

Flow Voltage  Type Part Number Price Type Part Number Price

131 CFM 120V, 50/60hz 1 MFFP100‐120‐1 $274 3R MFFP100‐120‐3R $452

131 CFM 230V, 50/60hz 1 MFFP100‐230‐1 $292 3R MFFP100‐230‐3R $470

140 CFM 24 VDC 1 MFFP100‐D24‐1 $310 3R MFFP100‐D24‐3R $488

300 CFM 120V, 50/60hz 1 MFFP200‐120‐1 $311 3R MFFP200‐120‐3R $564

300 CFM 230V, 50/60hz 1 MFFP200‐230‐1 $329 3R MFFP200‐230‐3R $582

300 CFM 24 VDC 1 MFFP200‐D24‐1 $347 3R MFFP200‐D24‐3R $600

750 CFM 120V, 50/60hz 1 MFFP500‐120‐1 $498 3R MFFP500‐120‐3R $820

750 CFM 230V, 50/60hz 1 MFFP500‐230‐1 $516 3R MFFP500‐230‐3R $838

304 STAINLESS STEEL

300 CFM 120V, 50/60hz 1 SFFP200‐120‐1 $363 3R SFFP200‐120‐3R $693

300 CFM 230V, 50/60hz 1 SFFP200‐230‐1 $381 3R SFFP200‐230‐3R $711

INJECTION MOLDED PLASTIC

80 CFM 120V, 50/60hz 1 PFFP080‐120‐1 $129 3R PFFP080‐120‐3R $333

80 CFM 230V, 50/60hz 1 PFFP080‐230‐1 $134 3R PFFP080‐230‐3R $338

80 CFM 24 VDC 1 PFFP080‐D24‐1 $144 3R PFFP080‐D24‐3R $348

131 CFM 120V, 50/60hz 1 PFFP100‐120‐1 $139 3R PFFP100‐120‐3R $343

131 CFM 230V, 50/60hz 1 PFFP100‐230‐1 $146 3R PFFP100‐230‐3R $350

140 CFM 24 VDC 1 PFFP100‐D24‐1 $154 3R PFFP100‐D24‐3R $358

300 CFM 120V, 50/60hz 1 PFFP200‐120‐1 $192 3R PFFP200‐120‐3R $438

300 CFM 230V, 50/60hz 1 PFFP200‐230‐1 $199 3R PFFP200‐230‐3R $445

300 CFM 24 VDC 1 PFFP200‐D24‐1 $209 3R PFFP200‐D24‐3R $455

390 CFM 120V, 50/60hz 1 PFFP390‐120‐1 $221 3R PFFP390‐120‐3R N/A

390 CFM 230V, 50/60hz 1 PFFP390‐230‐1 $228 3R PFFP390‐230‐3R N/A

390 CFM 24 VDC 1 PFFP390‐D24‐1 $235 3R PFFP390‐D24‐3R N/A

750 CFM 120V, 50/60hz 1 PFFP500‐120‐1 $276 3R PFFP500‐120‐3R $564

750 CFM 230V, 50/60hz 1 PFFP500‐230‐1 $294 3R PFFP500‐230‐3R $582

FILTER FAN SHROUDS

100‐FFP‐3R $178 100‐FFP‐3R304 $242

200‐FFP‐3R $253 200‐FFP‐3R304 $330

500‐FFP‐3R $322 500‐FFP‐3R304 $402

PARTS/LOUVERS ‐ PLASTIC VENT KIT

080‐PFFP 45003‐1 $24

100‐PFFP 45000‐2 $24

200‐PFFP 45001‐2 $30

500‐PFFP 45002‐1 $37

390‐PFFP 45005‐1 $37

PARTS/LOUVERS ‐ METAL VENT KIT

100‐MFFP 40045‐1T‐1 $82

200‐MFFP 40047‐1T‐1 $93

500‐MFFP 40049‐1T‐1 $202

REPLACEMENT ELECTROSTATIC POLYPROPYLENE FILTERS FOR FILTERED FAN PRODUCTS

Unit  P/N QTY. Price

MFFP100 44207 12 $46

MFFP200 44208 12 $71

MFFP500 44209 12 $135

PFFP080 44210 12 $30PFFP100 44211 12 $30PFFP200 44212 12 $40PFFP390 44213 12 $105PFFP500 44214 12 $63

2011_07_01

Heaters & Thermostat Products

HG Series Radiant HeatersP/N Heat Capacity Voltage Price

14000.0‐00 15W 110‐250V $3614001.0‐00 30W 110‐250V $4014003.0‐00 45W 110‐250V $5714005.0‐00 60W 110‐250V $6314006.0‐00 75W 110‐250V $7714007.0‐00 100W 110‐250V $8514008.0‐00 150W 110‐250V $100

HVL Series Fan Heater03102.9‐00 100W 120V $17503102.0‐00 100W 230V $17503103.9‐00 150W 120V $18103103.0‐00 150W 230V $18103113.9‐00 200W 120V $19303113.0‐00 200W 230V $19303114.9‐00 300W 120V $19903114.0‐00 300W 230V $19903115.9‐00 400W 120V $20603115.0.00 400W 230V $206

CR027 Fan Heater02700.0‐00 400W 220‐240V $22202700.9‐00 550W 100‐120V $22202701.0‐00 550W 220‐240V $24802701.9‐00 650W 100‐120V $248

CR030 Foot‐Mount HP Heater03059.9‐00 950W 120V, 50‐60Hz $26203051.0‐00 950W 230V, 50‐60Hz $26203060.9‐00 1200W 120V, 50‐60Hz $27903060.0‐00 1200W 230V, 50‐60Hz $279

KT Series Thermostat Scale01140.9‐00 NCF 32 ‐ 140F $2501141.9‐00 NOF 32 ‐ 140F $2501146.9‐00 NCC 0‐60C $2501147.9‐00 NOC 0‐60C $2501157.0‐00 NCC  ‐15 to +45C $25

ZR 011 Series Heater & Fan Control Scale01172.0‐01 32‐140 F 32‐140 F $4601172.0‐00 0‐60 C 0‐60 C $4601176.0‐00 0‐60 C 0‐60 C $4601176.0‐01 32‐140 F 32‐140 F $46

2012 / 01

Due to continous development, our information is subject to change without notice