Device Type Glossary 4009A4 Multipoint: 4 NACs Common This device type is used when connecting a basic 4009 NAC Extender Panel as a point on an IDNet. 4009A8 Multipoint 8 NACs Common This device type is used when connecting a 4009 NAC Extender Panel (expanded to control 8 NAC Circuits) on an IDNet. ADRPUL Addressable Pull Station This device type is used when adding an Addressable Pull Station to an IDNet. ANAMON Analog Monitor ZAM This device type is used when adding an analog device (such as VESDA) to an IDNet. CANPUL Canadian 2-Stage Pull Station This device type is used when adding a Canadian 2- Stage Pull Station to an IDNet. COMBO Multipoint: Common, Normal Base CPHOTO Caged TrueAlarm Photo This device type is used when connecting to a Caged Photo Sensor (used in gyms and prisons) . CRPHOTO Caged True Alarm Photo w/ Relay This device type is used when connecting a Caged Photo Sensor with a Relay Base to an IDNet (used in gyms and prisons).

Device Type Glossary

Embed Size (px)

DESCRIPTION

fire devce

Citation preview

Device Type Glossary4009A4 Multipoint: 4 NACs Common

This device type is used when connecting a basic 4009 NAC Extender Panel as a point on an IDNet.

4009A8 Multipoint 8 NACs CommonThis device type is used when connecting a 4009 NAC ExtenderPanel (expanded to control 8 NAC Circuits) on an IDNet.

ADRPUL Addressable Pull StationThis device type is used when adding an Addressable Pull Stationto an IDNet.

ANAMON Analog Monitor ZAMThis device type is used when adding an analog device (such as VESDA) to an IDNet.

CANPUL Canadian 2-Stage Pull StationThis device type is used when adding a Canadian 2-StagePull Station to an IDNet.

COMBO Multipoint: Common, Normal Base

CPHOTO Caged TrueAlarm PhotoThis device type is used when connecting to a Caged Photo Sensor (used in gyms and prisons)

.CRPHOTO Caged True Alarm Photo w/ Relay

This device type is used when connecting a Caged Photo Sensorwith a Relay Base to an IDNet (used in gyms and prisons). A separate 24 VDC is needed for the relay which is not part of the base.

CSPHOTO Caged True Alarm Photo w/ SounderThis device type is used when connecting a Caged Photo Sensorwith a Sounder Base to an IDNet (used in gyms and prisons). A separate 24 VDC is needed for the sounder.

CTPHOTO Caged True Alarm Single Station PhotoThis device type is used when connecting a Caged Photo Sensorwith a sounder base to an IDNet (used in gyms and prisons). A separate 24 VDC is needed for the sounder. Single station operation has the sounder activate when the Photo Sensor activates.

FRIAM Multipoint FRIAM Common

HEAT TrueAlarm HeatThis device type is used when connecting a TrueAlarm Heat Sensor to an IDNet.

IAM IAM MonitorThis device type is used when connecting an individual conventional device to an IDNet. (used if a 200 degree fixed-temp detector required).

ICOMBO Multipoint: Common, Isolator Base

IDNETISO IDNet IsolatorThis device type is used when adding an Isolator card to the IDNet.It is a mounted I a 4-inch square box and is part of the IDNet circuit.

IHEAT Heat w/ Isolator BaseThis device type is used when adding a Heat Sensor with an Isolator base to an IDNet.

IION Ion Sensor w/ Isolator BaseThis device type is used when adding an Ionization Sensor with anIsolator base to an IDNet.

IOHEAT Rate of Rise Heat w/Isolator BaseThis device type is used when adding a Heat Sensor with anIsolator base where the application calls for Rate-of-Rise detection.

ION TrueAlarm Ion

This device type is used when adding an Ionization Sensor to anIDNet.

IPHOTO Photo w/ Isolator BaseThis device type is used when adding a Photo Sensor with anIsolator base to an IDNet.

ISO IsolatorThis device type is used when adding a 4-loop Isolator card(must be physically located next to a MAPNET card).

KACPULL KAC Pull Station

MAZAM 1 Zone Class A Monitor ZAM – IDNetThis device type is used when adding a Class A Zone Adapter Module to an IDNet. A ZAM takes a conventional zone and makes it a point on an addressable system. A ZAM requires a separate 24 VDC.

MBZAM 1 Zone Class B Monitor ZAM – IDNetThis device type is used when adding a Class B Zone AdapterModule to an IDNet. A ZAM takes a conventional zone and makes it a point on an addressable system. A ZAM requires a separate 24 VDC.

MLPTIO Multipoint: MLPTIO Common

OHEAT True Alarm Heat w/ RORThis device type is used when adding a Heat Sensor where the application calls for Rate-of-Rise detection.

PHOTO TrueAlarm PhotoThis device type is used when adding a Photo Sensor to an IDNet.

POWERISO Power Isolator

This device type is used when adding a Power Isolator to an IDNet.Adding power isolators to the power circuit allows the circuit toisolate a 24 VDC short and not take down the entire power circuit.

R4009A4 Multipoint: 4 NACs Common w/ RepeaterThis device type is used when connecting a basic 4009 NACextender panel with a repeater card as a point on an IDNet. A repeater card re-amplifies the IDNet communications allowing the IDNet distance to be extended another 4000 ft. It does not allow more addressable devices.

R4009A8 Multipoint 8 NACs Common w/ Repeater(Expanded to control 8 NAC circuits) on an IDNetThis device type is used when connecting a 4009 NACextender panel (expanded to control 8 NACs) with a repeater card as a point on an IDNet. A repeater card re-amplifies the IDNet communications allowing the IDNet distance to be extended another 4000 ft. It does not allow more addressable devices.

RCOMBO Multipoint: Common, Relay Base

RELEASE Suppression Release Device

RHEAT TrueAlarm Heat w/ RelayThis device type is used when adding a Heat Sensor with a Relay Base. A separate 24 VDC is needed for the relay which is not part of the base.

RIAM Relay IAMThis device type is used when adding a Relay IAM to an IDNet. A separate 24 VDC is NOT needed for this module which mounts in a 4 square box.

RION TrueAlarm Ion w/ RelayThis device type is used when adding an Ionization Sensor with aRelay Base to an IDNet. A separate 24 VDC is needed for the relay which is not part of the base.

ROHEAT TrueAlarm Heat w/ ROR w/ RelayThis device type is used when application calls for a Heat Sensor with Rate of Rise and a Relay Base. A separate 24 VDC is needed for the relay which is not part of the base.

RPHOTO TrueAlarm Photo w/ RelayThis device type is used when adding a Photo sensor with a Relay base. A separate 24vdc is needed for the relay which is not part of the base.

SCOMBO Multipoint: Common, Sounder

SECIAM Security IAMThis device type is used when connecting an individual conventional Security device to an IDNet.

SHEAT TrueAlarm Heat w/SounderThis device type is used when adding a Heat Sensor with a Sounder base. A separate 24 VDC is needed for the sounder.

SION TrueAlarm Ion w/ SounderThis device type is used when adding an Ionization Sensor with aSounder base to an IDNet. A separate 24 VDC is needed for the sounder.

SOHEAT TrueAlarm Heat w/ ROR w/SounderThis device type is used when the application calls for a Heat sensor with rate of rise and a Sounder base. A separate 24 VDC is needed for the sounder.

SPHOTO TrueAlarm Photo w/ SounderThis device type is used when the application calls for a Photo Sensor with a Sounder base. A separate 24 VDC is needed for the sounder.

TION TrueAlarm Single Station IonThis device type is used when the application calls for an Ionization Sensor with a sounder base which is to operate as a single station. A separate 24 VDC is needed for the sounder. Single station operation has the sounder activate when the Photo Sensor activates.

TPHOTO TrueAlarm Single Station PhotoThis device type is used when the application calls for a Photo Sensor with a Sounder Base which is to operate as a Single Station Device. A separate 24 VDC is needed for the sounder. Single station operation has the sounder activate when the Photo Sensor activates.

TRIAM Multipoint: TRIAM Common

UHEAT Utility TrueAlarm HeatThis device type is used when the application calls for a Heat Sensor that does not alarm. One application would be a meat packing plant that would like to turn on a backup AC system if the temperature reaches 40 degrees.

UNUSED Unused This device type is used when the IDNet point is not used (a spare point).

XIPHOTO .2% Photo w/ Isolator BaseThis device type is used when adding an Extra Sensitive Photo Sensor with an Isolator Base to an IDNet.

XPHOTO Extra-Sensitive TrAlm PhotoThis device type is used when adding an Extra Sensitive Photosensor to an IDNet.

XRPHOTO Extra-Sensitive TrAlm Photo w/RelayThis device type is used when adding an Extra Sensitive Photo sensor with a Relay base. A separate 24vdc is needed for the relay which is not part of the base.

XSPHOTO Extra-Sensitive TrAlm Photo w/ SounderThis device type is used when the application calls for an Extra Sensitive Photo sensor with a Sounder base. A separate 24 VDC is needed for the sounder.

XTPHOTO Extra-Sensitive TrAlm sgl-station Photo This device type is used when the application calls for an Extra Sensitive Photo sensor with a sounder base is to work as a Single Station Device. A separate 24 VDC is needed for the sounder. Single station operation has the sounder activate when the Photo Sensor activates.