9
Site Plan Scale -1:100 3 A1 Project North True North Location Plan Scale - 1:600 1 A1 943 Collinson Ave., Victoria, B.C. Proposed 3 Unit Townhouse Development Townhouse Development, 943 Collinson Ave., Victoria, B.C. Site Plan/Data, Location Plan Scale - As Noted A1 February 16th., 2016 B A C D E F 3861 5588 6782 1168 1245 5 4 3 1 2 2121 3620 3416 2335 KING SIZE KING SIZE Unit C P L P L P L P L P L 7347 Front Yard Setback 305 Landscaping 17.238 31.612 16.764 Unit A Unit B 3962 Rear Yard Setback Grasscrete Permeable Pavers 4509 Landscaping 27.59m 7010 Patio 3613 Patio 1524 Exist. Cypress Cluster To Remain Landscaping Landscaping P L Garbage/ Recycling 6 space Bike Rack On 4" Thk. Conc. Pad 2757 598 3683 Side Yard Setback Project Information/ Site Data Table Front Yard , 9m Req.'d Rear Yard, 3m or 1/2 the bldng. ht. Open Site Space 165.5m2÷ 496.0m2 = .33, or 33% General One 6 Space Rack Zoning = R3-AM-1 Lot Area = 496.0m2 Floor Space Ratio Allowed Site Coverage = 30% Max. Height = 12m Parking, 1.4 stalls/unit = 4.2 Open Site Space = 30% Bicycle Parking (Racks) Class 1 Bicycle Parking Proposed Zoning If Different From R3-AM-1 10.66m 3 7.347m Max. = .9:1 For 3 Storeys 3 Landscaping Strip 300mm Area Calculations (m2/sq. ft.) Main Second Third Unit Unit A Unit B Unit C Sub-total 34.4/370.2 32.9/354.1 160.9/1,731.8 75.1/808.4 159.1/1,712.5 64.0/688.9 121.1/1,303.5 84.0/904.2 57.1/614.6 93.6/1,007.5 Rear Yard = 3.962m Side Yard Setback West = 3.683m Side Yard Setback East = 1.525m Building = 182.2m2 Lot Area = 496.0m2 Parking/Driveway = 148 .3m2 - 330 .5m2 Total = 330.5m2 = 165.5m2 198 .4m 2 496.0m2 = 40% Side Yard West, 3m or 1/2 the bldng. ht. Side Yard East , 3m or 1/2 the bldng. ht. Total 93.6/1007.5 166.6/1,793.2 180.9/1,947.2 444.1/4,747.9 Actual Floor Space Ratio 444.1(Total Floor area) ÷ 496.0 (Site Area) = .89:1 Variances Requested B A C D E F 5 4 3 2 2121 3620 3416 2335 3861 5588 6782 1168 1245 Plant List Project Location 103.76 ft. 90.54 ft. 55.00 ft. 56.55 ft. 943 Collinson Street Fairfield Road Vancouver Street Collinson Street Rem 1359 Strata Plan VIS3275 S'ly 80' of 1359 main floor =19.11 17.52 17.04 17.59 18.00 18.37 18.42 17.71 17.62 16.85 17.21 17.45 17.55 17.61 17.47 17.21 17.17 17.14 17.11 17.36 18.01 18.30 18.33 17.11 17.15 17.11 17.59 17.55 17.36 17.13 17.09 17.36 UP WM 17.34 17.36 17.00 17.18 17.06 17.12 17.07 17.64 17.36 17.07 16.85 16.62 16.98 17.00 17.01 17.05 17.03 20.11 peak= 17.97 18.41 18.49 18.49 17.29 17.43 17.42 17.57 18.14 17.30 fir spruce 17.51 spruce 16.38 16.62 16.75 17.01 17.30 17.50 lid=16.79 porch bay window cantilever eave=21.26 peak=23.97 retaining wall (top) (top) (top) (top) sidewalk curb mountable non asphalt driveway cypress cluster 25 25 40 (top) (top) (top) (top) (top) carport driveway No.943 A Plan 19753 garage retaining wall line of roof No.940 op of flat oof=27.93 .936 16.76 31.61 17.23 27.59 Lot Area = 496 m2 3.5 3.3 4.0 4.8 5.25 5.35 0.55 0.45 top of flat roof=29.55 roof=20.9 Survey Scale -1:100 3 A1 Project North True North Original Submission Received Date: February 16/16

Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

Site PlanScale -1:100

3A1

Project North

True

N

orth

Location PlanScale - 1:600

1A1

943 Collinson Ave., Victoria, B.C.

Proposed 3 Unit TownhouseDevelopment

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

Site Plan/Data, Location PlanScale - As Noted A1February 16th., 2016

BA C D E F3861 5588 6782 1168 1245

5

4

3

1

2

2121

3620

3416

2335

KING

SIZE

KING SIZE

Unit C

PL

PL

PLPL

PL

7347 Front Yard Setback

305

Landscaping

17.238

31.612

16.764

Unit A

Unit B

3962 Rear Yard Setback

Grasscrete Permeable Pavers

4509

Landscaping

27.59m

7010

Patio

3613

Patio

1524

Exist. CypressCluster To Remain

Landscaping

Landscaping

PL

Garbage/Recycling

6 space Bike Rack On 4" Thk. Conc. Pad

2757

598

3683

Sid

e Ya

rd S

etba

ck

Project Information/Site Data Table

Front Yard , 9m Req.'d

Rear Yard,3m or 1/2 the bldng. ht.

Open Site Space 165.5m2 ÷ 496.0m2 = .33, or 33%

General

One 6 Space Rack

Zoning = R3-AM-1

Lot Area = 496.0m2

Floor Space Ratio Allowed

Site Coverage = 30% Max.

Height = 12m

Parking, 1.4 stalls/unit = 4.2

Open Site Space = 30%

Bicycle Parking (Racks)

Class 1 Bicycle Parking

Proposed Zoning If Different From R3-AM-1

10.66m

3

7.347m

Max. = .9:1 For 3 Storeys

3

Landscaping Strip 300mm

Area Calculations (m2/sq. ft.)

Main Second ThirdUnit

Unit A

Unit B

Unit C

Sub-total

34.4/370.2

32.9/354.1

160.9/1,731.8

75.1/808.4

159.1/1,712.5

64.0/688.9

121.1/1,303.5

84.0/904.2

57.1/614.6

93.6/1,007.5

Rear Yard = 3.962m

Side Yard Setback West = 3.683m

Side Yard Setback East = 1.525m

Building = 182.2m2 Lot Area = 496.0m2Parking/Driveway = 148.3m2 - 330.5m2Total = 330.5m2 = 165.5m2

198.4m2496.0m2 = 40%

Side Yard West,3m or 1/2 the bldng. ht.

Side Yard East ,3m or 1/2 the bldng. ht.

Total

93.6/1007.5

166.6/1,793.2

180.9/1,947.2

444.1/4,747.9

Actual Floor Space Ratio 444.1(Total Floor area) ÷ 496.0 (Site Area)= .89:1

Variances Requested

BA C D E F

5

4

3

2

2121

3620

3416

2335

3861 5588 6782 1168 1245

Plant List

Project Location

103.7

6 ft.90

.54 ft.

55.00 ft.

56.55 ft.

943

Collinson Street

Fairfield Road

Vanc

ouve

r St

reet

Collinson Street

Rem

1359

Strata Plan

VIS3275

S'ly 80' of 1359

main floor=19.11

17.52

17.04

17.59

18.0018.37

18.42

17.7117.62

16.85

17.21

17.45

17.5517.61

17.47

17.21

17.1717.14

17.11

17.36

18.01

18.30

18.33

17.11

17.15

17.11

17.59

17.5517.36

17.13

17.09

17.36

UP

WM

17.34

17.36

17.00

17.18

17.06

17.1217.07

17.64

17.36

17.07

16.85

16.62

16.98

17.00

17.01

17.0517.03

20.11peak=

17.9718.41

18.4918.49

17.29

17.43

17.42

17.5718.14

17.30fir

spruce

17.51

spruce

16.38

16.62

16.75

17.01

17.30

17.50

lid=16.79

porch

bay window

cantilever

eave=21.26

peak=23.97

retaining

wall

(top)

(top)

(top)

(top)

sidewalk

curb

mountable

non

asphalt driveway

cypress

cluster

25

25

40

(top)(top)

(top)(top)

(top)

carport

driveway

No.943

A

Plan 19753

garage

retaining wall

line

of roof

No.940

top of flatroof=27.93

No.936

16.76

31.61

17.23

27.59

Lot Area = 496 m2

3.53.3

4.04.8

5.25

5.35

0.55

0.45

top of flatroof=29.55

roof

=20.

9

SurveyScale -1:100

3A1

Project North

True

N

orth

OriginalSubmissionReceived Date:February 16/16

Page 2: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

Main Floor PlanScale: 1/4" = 1'-0"

1A2

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

Main Floor PlanScale - As Noted A2February 16th., 2016

Main Floor FSR = 160.9m2

Unit A FSR = 34.4m2

Unit C FSR = 93.6m2

Unit B FSR = 32.9m2

BA C D E F3861 5588 6782 1168 1245

5

4

3

1

2

2121

3620

3416

2335

KING

SIZE

KING SIZE

Unit C

PL

PL

PLPL

PL

17.238

31.612

16.764

Unit A

Unit B

3940 5493 1702 6333

Elev.

Elev.

Garage

Garage

27.59m

Patio

Bedroom 2

Bathrm.

Storage

Storage

3613

Up

Up

Living Rm.

Kitchen

Dining

Fp.

FR.

W/D

R.

S.

DW. Cl.

3637

3277

1030

3572

Patio

CL.

Cl.

Bathrm.

Master Bedroom

Cl.

Cl.

Patio

Planter

Pantry

Cl.

2251

3524

3514

2263

Project North

True

N

orth

Page 3: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

Second Floor PlanScale: 1/4" = 1'-0"

1A3

Second Floor FSR = 159.2m2

Unit A FSR = 75.1m2Unit B FSR = 84.0m2

Up

Dn

Up

Dn

Cl.

Cl.

Cl.Master

Bedroom

Study

Bedroom 1

Bedroom 1

Unit A

Elev.

Elev.

Unit B

BathRm.

Bathrm.

Bathrm.

MasterBedroom

Laundry

LaundryW D

W

D

6015.6 3492.4 3750.7 4112.6Hall

Hall

BathRm.

Cl. Cl.S

Stair

Stair

A B C D

3821.8 5640.3 8013.6 1183.9

2

1

3

4

5

E

2311

.934

37.6

3480

.922

93.2

914.

452

88.2

5301

.1

Skylight Below

Cl. Cl.

Deck

Deck

Line OfThird Floor

Above

Project North

True

N

orth

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

Second Floor PlanScale - As Noted A3February 16th., 2016

Page 4: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

Third Floor FSR = 121.1m2

Unit A FSR = 57.1m2Unit B FSR = 64.0m2

Dn

Dn

A B C D

3821.8 5640.3 8013.6 1183.9

5767

5764

.1

1153

1

2

1

3

4

5

E

Unit A

2311

.934

37.6

3480

.922

93.2

Elev.

Elev. Unit B

1/2Bath

Dining

Fr.

R.

S.

LivingRoom

Fp.

Fr.

S.

Dining

LivingRoom

Kitchen

1/2Bath

Kitchen

Deck

Deck

R.

Pantry

Pantry

Fp.

Deck

Deck

Entrance CancopyBelow

Entrance CanopyBelowRoof Outline

Above

914.

448

42.3

5747

1214

2'-6" x 5'-0"Skylight Above

PrivacyScreen

PrivacyScreen

DW

2'-6" x 5'-0"Skylight Above

DW

Stair

4689.3 4107.9 3226

Decks Below@ Second Floor

Planter

6"x6" Clad Column

2'-6" x 5'-0"Skylight Above

3071

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

Third Floor PlanScale - As Noted A4February 16th., 2016

Third Floor PlanScale: 1/4" = 1'-0"

1A4

Project North

True

N

orth

Page 5: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

A B C D

3821.8 5640.3 8013.6 1183.9

5767

5764

.1

2

1

3

4

5

E

Deck At ThirdFloor

Deck At SecondFloor

2'6" x 5'-0" Alum.Framed Skylights

Deck At SecondFloor

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

Roof PlanScale - As Noted A5February 16th. 2016

Roof PlanScale: 1/4" = 1'-0"

1A5Project North

True

N

orth

Page 6: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

21 3 4 52300 3463 3640 2127

Unit 'C'Bedroom 2

Unit 'C'Bedroom 1

Unit 'A'LivingRoom

Unit 'B'LivingRoom

Unit 'B'MasterBedrm.

Unit 'A'MasterBedrm.

Unit 'C'Patio

3350

3350

3350

T/O Main FloorEl. = 17.30m Geodetic

T/O Second FloorEl. = 20.65m

T/O Third FloorEl. = 24.00m

U/S Third Floor Clng.El. = 27.35m

Average Fin. GradeEl. = 17.22m Geodetic

T/O Roof ParapetEl. = 27.88m

1066

0 M

ax. H

t.

535

80

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

SectionsScale - As Noted A6February 16th., 2016

Issued for Rezoning Purposes

Unit 'A'Garage

Unit 'A'StorageUnit 'C'

BedroomUnit 'C'

Living Rm.

Unit 'A'Master

Bedroom

Unit 'A'Ensuite

Unit 'A'LivingRoom

Unit 'A'Kitchen

Unit 'A'1/2

Bath

Unit 'A'Dining

Unit 'A'Bathroom

Unit 'A'Bedroom

Unit 'A'Patio

Unit 'A'Master

Bedroom

Unit 'A'Patio

Unit 'A'Patio 33

5033

5033

50

T/O Main FloorEl. = 17.30m Geodetic

T/O Second FloorEl. = 20.65m

T/O Third FloorEl. = 24.00m

U/S Third Floor Clng.El. = 27.35m

Average Fin. GradeEl. = 17.22m Geodetic

T/O Roof ParapetEl. = 27.88m

1066

0 M

ax. H

t.

535

80

A B C D E3184 6278 8013 1184

N/S Section Looking WestScale: 3/16" = 1'-0"

1A6

E/W Section Looking SouthScale: 3/16" = 1'-0"

2A6

Page 7: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

Floor FSR = 121.1m2

21 3 4 52300 3463 3640 2127

3 6

5

6 2

3

2

6

7

1

6

Skykights Beyond,See Roof Plan

2 13452300346336402127

3 6

5

1 2

Skykights Beyond,See Roof Plan

4

3

2

1 6

8

8

3

North ElevationScale: 3/16" = 1'-0"

4A7

South ElevationScale: 3/16" = 1'-0"

3A7

ABCDE3184627880131184

3350

3350

3350

T/O Main FloorEl. = 17.30m Geodetic

T/O Second FloorEl. = 20.65m

T/O Third FloorEl. = 24.00m

U/S Third Floor Clng.El. = 27.35m

Average Fin. GradeEl. = 17.22m Geodetic

T/O Roof ParapetEl. = 27.88m

1066

0 M

ax. H

t.

535

80

3 3

3

3

7

9

6

6

6

6

8

8

5

1 2

2 1 East ElevationScale: 3/16" = 1'-0"

2A7

West ElevationScale: 3/16" = 1'-0"

1A7

3350

3350

3350

T/O Main FloorEl. = 17.30m Geodetic

T/O Second FloorEl. = 20.65m

T/O Third FloorEl. = 24.00m

U/S Third Floor Clng.El. = 27.35m

Average Fin. GradeEl. = 17.22m Geodetic

T/O Roof ParapetEl. = 27.88m

1066

0 M

ax. H

t.

535

80

A B C D E3184 6278 8013 1184

MATERIAL LEGEND

1 Fibre Cement Panels W/ 5/8" Alum. Back RevealS & Exposed Fasteners (Colour-1)1

3 Pre-Fin. Metal Flashing

4 Topless Temp. Glass Guardrail in Alum. U-Channel Frame Secured To Structure

6 Dbl. Glazed Metal Clad Wood Windows & Doors

2 Fibre Cement Panels W/ 5/8" Alum. Back Reveals & Exposed Fasteners (Colour-2 )

7 3/8" Thk. Tempered Glass Privacy Screen W/ Frosted Patterned Film Applique'

9 Conc. Planter, Sack-rubbed Fin.

5 Topless Temp. Glass Guardrail Secured To Structure W/ S.S. Standoffs

8 Privacy Deck Screen Composed Of Fibre Cement Panels W/ 5/8" Alum. Back Reveals & Exposed Fasteners (Colour-2 )

3 3 6

6

6

6

8

8

1 2

2 1 1 1 2 2

Skykights Beyond,See Roof Plan

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

ElevationsScale - As Noted A7February 16th., 2016

Page 8: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

StreetscapeScale - As Noted A8February 16th., 2016

Issued for Rezoning Purposes

T/O Flat RoofElev. = 27.93mT/O Flat RoofElev. = 27.93m

T/OFlat RoofElev. = 29.55m 21 3 4 5

PL PL

3048

3353

3343

T/O Main Floor

El. = 17.28m Geodetic

T/O Second Floor

El. = 20.63m

T/O Third Floor

El. = 23.99m

U/S Third Floor Clng.

El. = 27.34m

60

Average Finished Grade

El. = 17.34m Geodetic

T/O Roof ParapetEl. = 27.87m

34' 6

5/8

"

534

Collinson Avenue StreetscapeScale: 1/8" = 1'-0"

1A8

Page 9: Development A1 Proposed 3 Unit Townhouse · 2016-02-19 · Proposed 3 Unit Townhouse Development Townhouse Development , 943 Collinson Ave. ... A2 February 16th ., 2016 Main Floor

TownhouseDevelopment,943CollinsonAve., Victoria, B.C.

RenderingsScale - As Noted A9February 16th., 2015

Issued for Rezoning Purposes

View From N.E.Not To Scale

1A9

View From N.W.Not To Scale

2A9

View From S.E.Not To Scale

3A9