27
Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans Pixel readout of gas detectors: Gridpix, Timepix, … Medipix, RELAXd 100 m RASNIK alignment

Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Embed Size (px)

DESCRIPTION

Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans. Pixel readout of gas detectors: Gridpix, Timepix, … Medipix, RELAXd 100 m RASNIK alignment. Micro Patterned Gaseous Detectors. GEM. High field created by Gas Gain Grids Most popular: GEM & Micromegas. Micromegas. - PowerPoint PPT Presentation

Citation preview

Page 1: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Detector R&D at NIKHEFSAC meeting, 20 April 2007

Jan Timmermans

• Pixel readout of gas detectors: Gridpix, Timepix, …

• Medipix, RELAXd• 100 m RASNIK alignment

Page 2: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Micro Patterned Gaseous Detectors

GEM

Micromegas

• High field created by Gas Gain Grids

• Most popular: GEM & Micromegas

Use ‘naked’ CMOS pixel readout chip as anode

Page 3: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Results pixel readout gas detectors

Observation of min. ionising cosmic muons: high spatial resolution + individual cluster counting !

δ ray

NIKHEF-Saclay-CERN-Twente

NIM A540 (2005) 295 (physics/0409048)

55x55 μm2 pixels

Page 4: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

TimePix(EUDET: Bonn,Freiburg, Saclay, CERN, NIKHEF)

•Distribute clock to full 256x256 pixel matrix (50-100-160MHz)

•Enable counting by first hit after ‘shutter’ opens, until ‘shutter’ closes (common stop); also time-over-threshold possible

•Dynamic range 214 x 10 ns = 160 μs

•(for the time being) no zero-suppress

to remain fully compatible with Medipix2

•Shaping time ~200 ns

•Keep same chip-size, pixel-size, readout protocol

•1st full reticle submit done July 2006; IT WORKS!

11 22 44

55

66

55μm

55μm

Page 5: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

First tracks with TimePix+SiProt+Micromegas:

cosmics + α particle

V_grid= -400 V; gain ~5000

He/Isobutane 80/20

Acquisition (‘shutter’) time ~ 1sec

Time_over_threshold mode pulseheight

Page 6: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

And triggered cosmics (sum of several triggers)

Shutter time = 15 μs

TimePix chip stayed alive for 40 days with He/isobutane 80/20

And ‘died’ on 26/1/07 after 1.5 day with Ar/isobutane 80/20

Blue = late

Red = early

Page 7: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

First INGRID tests

• Post-processing of a 4” wafer successful!– SiProt covered– InGrid– Diced to individual chips

• Handling critical• SU8 photo-resist dike

around the pixel matrix

• Perfect alignment pads/holes

• Pillars in between pads

Page 8: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

• 2 chips tested in He 20% iC4H10

• 55Fe signals at Vgrid = -280 V i.e. G ~ 200• Almost full homogeneous response• Still short lifetime (sparks even at low gains)

Micromegas covered Timepix

InGrid covered Medipix

Moire effects with Micromegas

Page 9: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

TwinGridAlternative:

Page 10: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Fred Hartjes 10

NIKHEF detector R&D meeting. January 23, 2007

MIP response for Gossip 21

charge signal (ke-)

0 10 20 30 40 50

# of

eve

nts

0

100

200

300

400

500

Measured histogramFitted convoluted PoissonAssumed pedestal peak

Vmesh = - 600 V

Vcath = -1000 V

Drift gap 1.2 mm=> Edrift = 3.3 kV/cm

pad pattern on glassBrass Micromegasgas: Kr/DME 74/26Exitation by mips from 90Sr source2.55% pedestal events14-2-2007

GOSSIP: 1.2 mm thin gas detector + Micromegas Gas: Kr/DME 74/26

Measured histogram with fitted convoluted Poisson

Cluster density calculated from two independent methods

1. Magnitude pedestal peak 2.55 +/- 0.07 % pedestal events

=> cluster density 39.1+/-0.8 cm-1

2. Fitting convoluted Poisson to experimental data

Using pdf =1 the best fit occurs at 38.2 +/- 2.6 cm-1 ¥

¥Note that this number depends on the pdf value

LiteratureCluster density Kr/DME 74/26: 40.2 cm-1

Page 11: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

GOSSIPO-2 chip:

• CMOS 130nm technology

• Multi-project wafer run (design ready Nov. 2006)

•16 x 16 pixels

•Each pixel: preamp, shaper, discriminator + 700 MHz clock (active for short interpolating period)

Waiting for the run to take place

Page 12: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Medipix and RELAXd

18 April 2007 - Jan Visschers

Page 13: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Medipix Collaboration

- Univ + INFN CagliariUniv + INFN Cagliari

- CEA-LIST SaclayCEA-LIST Saclay

- CERN Genève- CERN Genève- Univ d'Auvergne Univ d'Auvergne

- Univ Erlangen- Univ Erlangen

- ESRF Grenoble- ESRF Grenoble

- Univ Freiburg- Univ Freiburg

- Univ Glasgow- Univ Glasgow

- IFAE Barcelona- IFAE Barcelona

- Mitthoegskolan - Mitthoegskolan

Sundsvall Sundsvall

- MRC-LMB Cambridge - MRC-LMB Cambridge

- Univ + INFN Napoli- Univ + INFN Napoli

- - NIKHEF AmsterdamNIKHEF Amsterdam

- Univ + INFN Pisa- Univ + INFN Pisa

- FZU CAS Prague - FZU CAS Prague - IEAP CTU Prague IEAP CTU Prague - SSL Berkeley SSL Berkeley

Spokespersons: Spokespersons: Michael CAMPBELL CERNMichael CAMPBELL CERNJan VISSCHERS NIKHEFJan VISSCHERS NIKHEF

Page 14: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Quad Medipix

1sensor on 4 Medipix chips6-layer ultra-fine line designLaser-drilled micro-via’sKapton Buildup technology0.25 Megapixels

Page 15: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

RELAXd: Tile-able Microsystems

1. Edgeless Planar Silicon Sensors

2. Through-CMOS contacting

3. High-bandwidth readout

Medipix 2.1 ROIC

1. Canberra

2. IMEC

3. NIKHEF4. PANalytical (application)

Eureka Project

Page 16: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Raw image of 90Sr source with current Quad carrier.

Page 17: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Medipix ASIC

Through-CMOS connections

Multi-layered chip carrier board

Medipix ASIC

Quad sensor

• Through-silicon interconnect• Medipix wafer thinning: 100 um• Ball-Grid Array on the back side of the Medipix chip• Balls 500 um diameter, 800 um pitch

Page 18: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Frame and Cooling

Large area (9x9 cm2)< 100 Watts total powerCeramics FrameCooling pipes through framePower through frame

Page 19: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Roadmap

Through-via carrierZdenek Vykydal

Multi-Gbps carrierBas van der Heijden

RELAXD module(end 2007)John Hug

Current Quad

Frame, Power,Cooling (2009)

Page 20: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

100m RASNIK alignment

Harry van der Graaf

Page 21: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Coded Mask

Light Source LensCCD

8000 systems installed in ATLAS

Principle of CCD-RASNIK(as used for muon chamber alignment in L3)

Page 22: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

100 m RASNIK for CLICCLIC

Accelerator length: 2 x 15 kmNumber of elements: 15.000Number of ‘4 m’ RASNIKs: 15.000/30.000Number of ‘100 m’ RASNIKs: 600

Laser zone lenshole dia. 50 mm

RasCam

100 m (vacuum tube!)

Page 23: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans
Page 24: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Image position on sensor. Response of earthquake in Mid-Atlantic,5 Richter Scale, on March 1, 2007

Page 25: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

Tidal movement: crust deformation due to angular positionof Sun and Moon, measured with RasClic, CERN, Geneva (filtered raw data)

Page 26: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

The ‘Earth Hum’, measured after the ‘tsunami’ earthquake, Xmas 2004[Park et al]

Page 27: Detector R&D at NIKHEF SAC meeting, 20 April 2007 Jan Timmermans

(Direct) Fourier coverted raw X-data of RasClic, Feb 2007New wide-band seismometer?

‘Hum’ modes