Detective-EX-100T and Detective-DX-100T HPGe-based Hand-Held Radioisotope Identifiers

Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

Embed Size (px)

Citation preview

Page 1: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

Detective-EX-100T andDetective-DX-100T

HPGe-based Hand-Held Radioisotope Identifiers

Page 2: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

2

Detective-EX/DX-100T

The ORTEC Detective family of Hand-Held Radioisotope Identifiers (HHRIDs) has gained an unmatched reputation for performance in the rapididentification of radioisotopes in both suspected and actual cases of illicit nuclear materials trafficking. Detective Version 3 analysisenhancements push the performance envelope even further.

ORTEC Detectives are deployed ever more widely in the battle against illicit nuclear trafficking. Hundreds are being used world wide by (amongothers):

Departments of Homeland Security Emergency Management TeamsDepartments of Defense Civil Support TeamsNational Security Organizations Police DepartmentsBomb Disposal Teams Nuclear Safeguards OrganizationsEmergency Response Teams Nuclear Fuel ManufacturersCustoms and Border Control Nuclear ResearchersNavy, Army and Air Forces US NNSA second line of defense “Megaports” initiativeInternational Atomic Energy Agency

1High resolution High Purity (HPGe) Detector.2Neutron detection is only available on “EX” models.

Benefits• Highest performance HPGe nuclide identifier: now improved

further by latest advanced algorithms.• High resolution gamma spectroscopy1 with confirmatory neutron

detection in EX models.• Definitive answers to the detection of illicit nuclear materials

(SNM) trafficking in seconds, in a battery operated instrument.• Fast, Simple and ULTRA-Reliable Classification of NORM,

Medical, Industrial, SNM and Natural Isotopes, shielded andunshielded.

• ANSI N42-34 compliant.• Simple to Operate: Bright, Clear Displays, touch sensitive screens,

intuitive menus.• Multiple uses (e.g.): Hand-Held Nuclide Identifier, Emergency

Whole-Body Counter, Ad-hoc Portal Monitor, Search System,Food Monitor.

• Gamma-Ray and Neutron Search Modes.2

• SNM Search Mode™ finds SNM sources in the presence of othersources.

• Compatible with Detective-Remote search system.• USB and Wireless 802.11 Communications.• Wireless Mobile MCB Server software.• Built in GPS.• Secure Digital (SDIO) slot.

Software Features• Three “Search Modes”:

Gamma/neutron total count rateSNM Search modeSliding average “monitor” mode

• User choice of identification schemesClassify Mode (by nuclide type: “nuclear, natural, medical,industrial, etc.”)ANSI modeTime preset or continuous count selectable to match CONOPSSuspected Nuclides (not in preset mode)More sensitive LCX mode for SNM detection

• Background collect feature eliminates reporting of backgroundnuclides.

• “Smart” spectrum stabilizer ensures optimum results, even withhard-to-analyze spectra.

• ANSI N42.42 format storage of spectra.

Models• Detective-EX-100T: The Detective-EX made faster! A larger

65 mm x 50 mm HPGe detector version of the -EX.• Detective-DX-100T: “Gamma only” versions of the

Detective-EX-100T.

Page 3: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

Operational Capabilities(all models except where noted)SEARCH MODES: Gamma andneutron (if applicable) count rates arepresented as a time tracking stripchart. Neutron counts are displayed inred and gamma counts in blue.MONITOR MODE: Detective collectsone spectrum per second and runsthe ID algorithm against an 8 secondsliding average. More sensitive tosources which move relative to theinstrument. Monitor mode is avaluable search method, but is alsouseful, for example, in ad-hoc portalmonitoring applications.SNM Search Mode: SNM Searchmode is designed to help avoid falsenegatives when determining SNM. Ithelps in finding the point of maximumcount rate which COULD beconsistent with SNM.Key regions of the spectrum aremonitored which are critical to thedetermination of both U-235 (the keyconstituent of HEU) and Pu-239. Thepeak region confidence level isdisplayed in the form of a bar graph. Ahigh and steady reading indicates that"something" is present which is worthyof more investigation. Once themaximum reading has been located,the "confirm" key initiates the fullidentification algorithm.SNM Search mode is an INDICATORof SNM but should always be followedby the confirmatory ID to avoid falsepositives. In combination, SNMSearch and ID modes minimize BOTH false negatives and falsepositives.

GAMMA DOSE RATE: Gamma Dose Rate is monitored by theHPGe detector and by an internal compensated GM tube. The doserate is displayed at all times. Dose rate units may be chosen asµSv/hr or mrem/hr.NEUTRON COUNT RATE (-EX models): Neutron Count Rate isdisplayed continuously. The data can be quickly saved andtransmitted for further offsite analysis.GPS Position Information: An internal GPS receiver displays GPScoordinates which may be saved along with spectrum data for futureuse.Storage of Data (spectrum, search data, ID results): To internal RAMand removable SD card.Computer Interfacing: USB connection to laptop. Spectral transferby MicroSoft® ActiveSync. Remote control via MicroSoft“remotedsp.exe”. Wi-fi (802.11) communication. All models feature a large, bright andclear LCD Display with touch-sensitivescreen. The figure shows the mainoperator screen. Gamma and neutron(-EX) count rate and gamma dose rateare displayed continuously bothnumerically and in bar graph form. Thebattery life remaining is shown at thetop.

Operating ModesIn response to customer requests,Detective instruments can now operate in two modes “Classify” and“ANSI”. Classify Mode: The user presses the Identify button and theinstrument gathers data until manually stopped, without preset.During the acquisition, suspected nuclide classification messagesappear, such as “Suspect Industrial 1”, meaning the presence of oneindustrial nuclide is suspected. As the count continues andconfidence levels increase, this might change to “Found Industrial 1”or disappear as better statistics determine the previously suspectednuclide was not, in fact, present. Clicking on the “Found” or “Suspect”message gives a listing of which nuclides were actually found (orsuspected) by name.ANSI Mode: This mode is similar to classify mode, but dispenseswith the classification, and presents nuclide names directly, bothsuspect and found.

3

Detective-EX/DX-100T

Page 4: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

Preset Time: This is to allow forCONOPS* in which it is required tocount for a preset time, for example60 seconds. At the end of the presetperiod, only what has been found isreported, no suspects are reported.The operator can request a count timeextension, if desired, adding multiplesof the original preset period. LCX (Low-Confidence Expert) IDMode: LCX mode is passwordprotected. LCX denotes “LowConfidence-Expert,” and is intendedfor expert users. This identificationmode displays suspected threatalarms and identifications at a lowerconfidence level than the normalmode. This results in more hits on suspected threat nuclides.Instrument Calibration: The instrument is calibrated prior toshipment from the factory. The energy calibration may be checkedand adjusted with any known source with a clean gamma raybetween 0 and 3 MeV. A higher energy is recommended. Cs-137 isoften used. Calibration can be manual or automatic. Backgroundcollection is now a required part of calibration. By allowing foractivities already in the background, the system will no longer reportnuclides detected in the background. These IDs on former versionssometimes lead to user-confusion. The background must be updatedon a schedule which is chosen by the privileged user.SMART Stabilizer: The “smart stabilizer” stabilizes the gain veryprecisely on the 1460 keV peak of K-40, if present. The smart part isthat if there is no K-40 present or if Eu-152 is detected, which couldinterfere with the K-40 peak, the stabilizer setting is held but notadjusted until “normal” conditions return. Even though the Detectiveis a highly stable instrument, the smart stabilizer allows accuratedetermination of more complicated mixed spectra.

Classify ModeThe form of the primary ID messages is:

"Found CLASS(#)" or "Suspect CLASS(#)"where “CLASS” is

MedicalIndustrialNORMBremsstrahlungOtherNuclear UraniumNuclear PlutoniumNuclear Neptunium

And "#" is the number of nuclides of that class identified.The following table lists the Detective Library v8.5 radionuclidesaccording to their categories in the “Classify” ID mode.

4

Detective-EX/DX-100T

*Concept of Operations.

IndustrialAm-241Am-241 (unshielded)Cs-137Ho-166mHo-166m (shielded)Ir-192Ir-192 (shielded)W-187Ac-227Ag-110mAr-41As-72Au-198Ba-133Ba-140Be-7Bi-212 (Th-232/U-232 daughter)Br-77Ca-47Cd-115Ce-144Cm-242Cm-243Cm-244Co-55Co-57Co-57 (shielded)Co-60Cs-134Hf-181Hg-203I-126I-126 (shielded)

I-132I-133I-134I-135Kr-87Kr-88Kr-88 (shielded)Mn-52Mn-56Nb-92mNb-94Nb-95Nb-96Nb-96 (shielded)Nd-147Pa-231Pb-203Pr-144Ra-223Rh-105Ru-103Ru-97Sb-124Sb-124 (shielded)Sb-125Sb-127Sr-85/Kr-85Tc-96Te-132Th-229Th-230Tm-171W-188/Re-188

Page 5: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

5

Classify Mode MessagesThe following explains the criteria for selected Classify ID DisplayMode messages.HEU (highly enriched uranium): This message is displayed if themajor lines of uranium are detected and the ratios of the intensities ofthe lines indicates the U-235 content to be above about 70%.Am241 (unshielded) in the “Industrial” category: This message isdisplayed if the 59 keV peak is located. It could mean that an Am-241source such as a smoke detector is present. Move closer to thesource and/or count longer. This will allow the higher-energy gammarays to accumulate in the spectrum, in case plutonium is alsopresent.Unknown Peak and Unknown/Beta Emitter: This indicates thegamma count rate is higher than can be accounted for based on thepeaks in the library. The implication is that either an unexpectednuclide or a beta emitter is present (beta emitters typically producingcounts over a broad range of energies). Move closer to the sourceand count longer to determine the nature of the suspect item. Ifanother ID is found, then the Unknown Peak or the Unknown/BetaEmitter ID are suppressed.“Found Nuclide” Screen MessagesRDD Detected: This message is posted when estimated activity is>100 mCi, whether the activity is from threat or innocent nuclides.The gamma count rate and dose rate meters on the Survey Modeand ID Mode screens display a flashing red background andextremely high count and dose rates.ANSI Mode MessagesThe table is divided according to the threat category used todetermine ID background color in Monitor Mode and on the Foundand Suspect Nuclide reports, e.g., green for innocent IDs, yellow forLCX-mode suspects, and red for threats. NB: if desired and underpassword protection, the color coding, and therefore the threatclassification can be disabled.

MedicalF-18I-125Lu-177Lu-177mMo-99Pd-103Se-75Sm-153Sm-153 (shielded)Tc-99mXe-133Ac-225As-74Ce-139Ce-141Co-58Ga-67Ga-67 (shielded)Ge-68/Ga-68I-123I-123 (shielded)

I-124I-131I-131 (shielded)In-111Lu-172Na-24Rb-83Rb-86Ru-106/Rh-106Sc-46Sr-82/Rb-82Sr-89Tl-201Tl-204Tm-170V-48Xe-133mYb-169Zn-62Zn-65Zr-95

NORMLa-138Ra-226Bi-214 (Ra-226 daughter)

K-40Lu-176Th-232

OtherCr-51Cu-64Eu-152Gd-159La-140Mn-54Neutrons on FeNeutrons on HydrogenUnknown PeakUnknown/Beta emitterXe-131mAt-211Bi-207Br-76Br-76 (heavily shielded)Br-76 (shielded)Cd-109Co-56Co-56 (shielded)

Eu-154Eu-155Eu-156Fe-59Ga-64Ga-64 (shielded)Gd-153Ho-166Ir-194 (shielded)Na-22NeutronsOs-194/Ir-194Po-210Sn-113Ta-182Tl-200Tl-202Xe-135Y-88

BremsstrahlungBeta emitter

Nuclear UraniumEnriched UraniumHEUU-232U-233

U-235U-238186 keV peak present2614 keV peak present

Nuclear PlutoniumPu-239Pu-238

375/414 peak presentAm-241 (shielded)

Nuclear NeptuniumNp-237

Detective-EX/DX-100T

Page 6: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

6

Detective-EX/DX-100T

Identification Classification Identification ClassificationInnocent

Ac-225 MedicalAc-227 IndustrialAg-110m IndustrialAm-241 (unshielded) IndustrialAr-41 IndustrialAs-72 IndustrialAs-74 MedicalAt-211 OtherAu-198 IndustrialBa-133 IndustrialBa-140 IndustrialBe-7 IndustrialBeta emitter BremsstrahlungBi-207 OtherBi-212 (Th-232/U-232 daughter) IndustrialBi-214 (Ra-226 daughter) NORMBr-76 OtherBr-76 (heavily shielded) OtherBr-76 (shielded) OtherBr-77 IndustrialCa-47 IndustrialCd-109 OtherCd-115 IndustrialCe-139 MedicalCe-141 MedicalCe-144 IndustrialCm-242 IndustrialCm-243 IndustrialCm-244 IndustrialCo-55 IndustrialCo-56 OtherCo-56 (shielded) OtherCo-57 IndustrialCo-57 (shielded) IndustrialCo-58 MedicalCo-60 IndustrialCr-51 OtherCs-131 MedicalCs-134 IndustrialCs-137 IndustrialCu-64 OtherCu-67/Ga-67 MedicalEu-152 OtherEu-152 OtherEu-154 OtherEu-156 OtherF-18 MedicalFe-59 OtherGa-64 Other

Ga-64 (shielded) OtherGa-67 MedicalGa-67 (shielded) MedicalGd-153 OtherGd-159 OtherGe-68/Ga-68 MedicalHf-181 IndustrialHg-203 IndustrialHo-166 OtherHo-166m IndustrialHo-166m (shielded) IndustrialI-123 MedicalI-123 (shielded) MedicalI-124 MedicalI-125 MedicalI-126 IndustrialI-126 (shielded) IndustrialI-131 MedicalI-131 (shielded) MedicalI-132 IndustrialI-133 IndustrialI-134 IndustrialI-135 IndustrialIn-111 MedicalIr-192 IndustrialIr-192 (shielded) IndustrialIr-194 (shielded) OtherK-40 NORMKr-87 IndustrialKr-88 IndustrialKr-88 (shielded) IndustrialLa-138 NORMLa-140 OtherLu-172 MedicalLu-176 NORMLu-177 MedicalLu-177m MedicalMn-52 IndustrialMn-54 OtherMn-56 IndustrialMo-99 MedicalNa-22 OtherNa-24 MedicalNb-92m IndustrialNb-94 IndustrialNb-95 IndustrialNb-96 IndustrialNb-96 (shielded) IndustrialNd-147 IndustrialOs-194/Ir-194 Other

Page 7: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

7

Identification Classification Identification ClassificationPa-231 IndustrialPb-203 IndustrialPd-103 MedicalPo-210 OtherPr-144 IndustrialRa-223 IndustrialRa-226 NORMRb-83 MedicalRb-86 MedicalRh-105 IndustrialRu-103 IndustrialRu-106/Rh-106 MedicalRu-97 IndustrialSb-124 IndustrialSb-124 (shielded) IndustrialSb-125 IndustrialSb-127 IndustrialSc-46 MedicalSe-75 MedicalSm-153 MedicalSm-153 (shielded) MedicalSn-113 OtherSr-82/Rb-82 MedicalSr-85/Kr-85 IndustrialSr-89 MedicalTa-182 OtherTc-96 IndustrialTc-99m MedicalTe-132 IndustrialTh-229 IndustrialTh-230 IndustrialTh-232 ThoriumTl-200 OtherTl-201 MedicalTl-202 OtherTl-204 MedicalTm-170 MedicalTm-171 IndustrialV-48 MedicalW-187 IndustrialW-188/Re-188 IndustrialXe-127 IndustrialXe-131m OtherXe-133 MedicalXe-133m MedicalXe-135 OtherY-88 OtherY-91 IndustrialYb-169 MedicalZn-62 Medical

Zn-65 MedicalZr-95 Medical

Suspect (LCX Mode only)186 keV peak present Uranium2614 keV peak present Uranium375/414 peak present Plutonium

ThreatAm-241 IndustrialAm-241 (shielded) PlutoniumEnriched Uranium UraniumHEU UraniumNeutrons OtherNeutrons CR NeutronNeutrons on Fe OtherNeutrons on Hydrogen OtherNp-237 NeptuniumPu-238 PlutoniumPu-239 PlutoniumU-232 UraniumU-233 UraniumU-235 UraniumU-238 UraniumUnknown Peak OtherUnknown/Beta emitter Other

Detective-EX/DX-100T

Page 8: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

8

Detective-EX/DX-100T

DisplayAll -EX/-DX models feature the samebright and clear VGA resolutiondisplay with touch sensitive operatorscreen. Menu navigation is highlyintuitive. The radionuclide gamma-ray spectrum may be displayed andmanipulated (e.g., vertical scale,zoom) like a conventionalmultichannel analyzer. Y-axis unitsare now displayed.

Power SourcesDetective can draw power froma variety of sources. For initialcool down from ambienttemperature, the Detective isplaced on the docking station,or attached to the compact AC/Power Adapter/Charger (PAC). Thedocking station provides small air movers to assist with initial cooldown in conditions of high ambient temperature (>40°C) andincorporates a source holder for the optional CS-137 calibrationcheck source. The docking station is recommended for high ambienttemperatures. The PAC is the much more compact solution. K-40,as found in dietary salt substitute, is an easy to obtain calibrationcheck source for use with the PAC.The optional source is ~0.25-µCi (9250 Bq) solid and sealed. It is anexempt quantity under U.S. and European regulations and is onlysupplied pre-installed by ORTEC (not separately).

Gamma-Ray Identification Performance Datafor Uranium and Plutonium (Typical values based on data obtained from actual measurementsby ORTEC personnel.)Single SourcesUnless otherwise stated, these data were taken at a standard doserate from the source of 500 nSv/h measured with a calibrated doserate meter at the instrument detector face according to ANSIN42.34. When an absorber was present, the dose rate at thedetector was measured THROUGH the absorber.Unshielded and Shielded Uranium: DU, U-NAT, LEU, HEUThe time to identify as uranium, either unshielded or shielded by upto 5 mm steel, is <2.5 sec. For LEU and HEU samples, the type("LEU" or "HEU") is also reported in <2.5 sec. LEU and HEUsamples shielded by 1.6 mm lead are identified as Uranium in<2.5 sec.

Unshielded and Shielded Plutonium: Weapons Grade (WG),Reactor Grade (RG) (~60–93% 239Pu)Time to identify as Pu, unshielded or shielded by up to 5 mm steelor 10 mm lead: <13 seconds for all types of Pu (with Cd filter if highAm content). For WG Pu the type "WG Pu" is also reported in lessthan <35 sec.MixturesIn all cases, the mixture consists of 500 nSv/h of the "mask" nuclide,added to the specified quantity of uranium or plutonium. The "doseratio threshold" is defined to be the standard 500 nSv/h dose ratefrom the mask in ratio to the smallest dose rate from U or Pudetectable in the time stated.Uranium at 500 nSv/h in the presence of Cs-137 or Co-57 mask(unshielded)Time to identify as uranium <2.5 sec. For LEU and HEU, the type("LEU" or "HEU") is also reported in <2.5 sec.Uranium Dose ratio threshold for 60 second measurement inthe presence of Cs-137 or Co-57 mask (Dose from mask: Dosefrom uranium)>7:1 for identification as uranium unshielded>3:1 shielded 5 mm steel>2:1 for reporting as LEU or HEU unshielded>1.5:1 shielded 5 mm steelPlutonium at 500 nSv/h in the presence of Ba-133 maskTime to identify as Pu <20 sec, unshielded or shielded by 5 mmsteel or 10 mm lead. Identified type as RG Pu or WG Pu in<100 sec.Plutonium Dose ratio threshold for 5 minute measurement inthe presence of Ba-133 mask>6:1 for identification as Pu unshielded, >4:1 shielded by 5 mm steelor 10 mm lead.>1:1 for reporting as WG Pu or RG Pu unshielded or shielded by5 mm steel or 10 mm steel (with Cd filter if high Am content).

Analysis Algorithm ImprovementsDetective series instruments have proven highly resistant to falsepositive and false negative results. Recent improvements to theDetective algorithms have enhanced this already excellentperformance still further. In Version 3, the implementation of thebackground subtraction has removed the reporting of nuclidesidentified in the background. While technically not an incorrectresult, reporting of background nuclides was considered undesirableby some experts. The smart stabilizer has improved the analysis ofsome difficult masking scenarios.

Page 9: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

9

OPERATION MODESSEARCH Scanning mode for location of radioactive sources, with audioalert using an external ear piece. Both neutron and gamma search issimultaneous; speed settings 1 to 50 seconds/point.SNM Search Mode™ Nuclide-specific search mode for U-235, Pu-239 andneutron counts. Ba-133 surrogate detection may be turned on for trainingpurposes. Bar graph display of nuclide confidence level. Aid to Identifymode.MONITOR Mode The instrument collects one spectrum per second andruns the ID algorithm against an 8 second sliding average. This mode ismore sensitive to sources which move relative to the instrument.LCX “Low confidence Expert” Mode.IDENTIFY Gamma Proprietary scheme for identification and classificationof radionuclides. Background subtraction.ANSI Mode: See nuclide list above.Classify Mode:

Nuclides classified according to:IndustrialMedicalNatural (NORM)Nuclear

These classifications are based on an internal, fixed library according toANSI N42.34. Customized libraries for specific applications can be suppliedby special order.Remote Mode Detective V3 instruments can participate as nodes withinthe Detective Remote search system. Dose Rate Visual over range indication and continuous audible alarm, usersettable. Over-ride alarm at dose rates >10,000 µSv/hr.

DETECTORSInternal HPGe DetectorCrystal Nominal Dimensions: 65 mm diameter x 50 mm deep.P-type high-purity germanium. Coaxial construction.Cooler: High reliability, low power Stirling cooler. Cooler design life >5 yearscontinuous running. Dual piston design, 1 W nominal lift at 100°K.Digital Noise Suppression: "LFR Filter," ORTEC Patent Pending.Gamma Dose Rate Detector Two detectors determine the gamma doserate over a wide range from <0.05 µSv/h to >10000 µSv/h, a dose raterange of around six decades. For low dose rates, below ~20 µSv/h, thedose rate is determined from the Ge detector spectrum. For dose ratesabove this value, the internal compensated GM tube is used. Instrumentswitches between the two automatically.Dose rate uncertainty <(–50% to +100%); continuous audible alarm at doserates >10,000 µSv/h (fixed maximum threshold), user settable thresholdbelow this.Neutron Detector Module (-EX model only) 4 tubes: 4" active length, 0.5"diameter. High Density Polyethylene moderator.

DIGITAL MCA AND DATA PROCESSORDisplay VGA 640 x 480 TFT sunlight readable touch sensitive, operatewith finger or stylus.Data Processor Marvel 806 MHz XScale.Data Storage (Spectrum, Search Data, ID Results) To internal RAM andremovable SD card.Computer Interfacing USB connection to laptop. Spectral transfer byMicrosoft® ActiveSync. Remote control via Microsoft “remotedsp.exe”. Wi-fi(802.11) communication software. Wireless Mobile MCB Server software.GPS Internal NMEA compliant WAAS capable.Digital MCA with Internal Storage of Multiple Spectral Data. “Smart” digitalspectrum gain stabilizer.Digital Noise Suppression LFR Filter.Conversion Gain 8k channel.Maximum Number of Stored Spectra Unlimited on removable media.

DISPLAYS AND MENUSMain ScreenGamma Count Rate Bar Graph 20 kcps full scale. Dose Rate Bar Graph 10 mSv/hr full scale, flashes on over range.Status Lines:

WARNING!! High Dose Rate — Displayed when Dose rate exceeds10 mSv/hr.Detector is Warm — Displayed when crystal temperature is aboveworking limit.Bias Supply Error — Displayed if any power supply is bad.WARNING!! Low Battery.

Search Mode (Gamma/Neutron) Dwell times 0.1 to 50 seconds per point.Over-range warning.SNM Search Mode™ Nuclide-specific search mode for U-235 and Pu-239.Bar graph display of nuclide confidence level. Identify Nuclide ID and classification."Intense" shows the most intense lines list, which is a continuouslyupdating list of the 12 best peaks currently detected. The nuclides andenergies are based on the internal nuclide library. The rank is based on theconfidence value for the peak."Save" Saves the spectrum. Format choices: ORTEC “.CHN”, ORTEC“.SPC” and ANSI N42.42."Display" brings up the spectral display. The spectrum may bemanipulated via the arrow keys and various accelerator keys for cursormovement. Energy and channel contents are displayed with the spectrum.Advanced Setup Password protected.

Specifications

Detective-EX/DX-100T

Page 10: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

10

Detective-EX/DX-100T

Calibration Check Manual or Automatic Calibration Check. Automatic maybe triggered by interval or time of day. Instrument is supplied calibrated fromfactory.View Data Acquisition Parameters Reports instrument status.

PHYSICAL SPECIFICATIONSMaximum Overall Dimensions (including handle, Ge detector end cap andshock absorbers)Detective-EX-100T 39.4 cm L x 18.3 cm W x 34.9 cm H

(15.5" L x 7.2" W x 13.75" H)Detective-DX-100T 39.4 cm L x 16.3 cm W x 34.9 cm H

(15.5" L x 6.55" W x 13.75" H)WeightDetective-EX-100T 26.3 lb (12 kg)-DX-100T versions are 1.9 lb (0.9 kg) lighter.Internal Battery Life >3 hours at 25°C when HPGe detector is cold.Battery lifetime may be extended indefinitely by the use of external batterypacks which are available in "battery belt" formats.Input Power 10 to 17 V DC 30 W or from battery or auto-sensing Mainspowered Battery Charger.External Power DC In and battery Charge In. MS3112E12-10-s or BendixPT02E-12-10S connector.TemperatureOperation Range: –10°C to 40°C.Relative Humidity: <90% at 35°C, non-condensing.Communications PortsExternal Connectivity to System• 1 SD (Secure Digital) card slot (3.3 V).• 1 USB connection for "ActiveSync" capability or MCA operation with

external computer (ActiveSync and remote display software included).• WiFi 802.11 communication software.• Wireless Mobile MCB Server software.• 1 Audio headphone jack.Cool Down Time The high reliability cooler is designed for continuousoperation. Between making measurements the unit is powered from a DCsupply, car battery or other high capacity device. Initial cool down timedepends on ambient temperature, but is typically <12 hours at 25°C.

COMMUNICATIONS SOFTWAREThe Detective-EX-100T and Detective-DX-100T are members of theORTEC CONNECTIONS family. Remote MCA control and individualspectrum download, even over a network, is achieved simply, by the use ofORTEC CONNECTIONS products such as MAESTRO MCA Emulationsoftware.Detective-EX-100T/-DX-100T are fully supported by the latest versions ofthe highly successful MAESTRO MCA Emulator as well as ORTEC GammaSpectroscopy Packages such as GammaVision for generalized HPGespectrum analysis, FRAM and MGAHI for Pu and U isotopic ratio analysisand ISOPlus for in-situ waste assay analysis. NOTE: MAESTRO is suppliedas part of packages containing "PKG" in the model number, or it can bepurchased separately at a later date.The integral USB connection in the instrument hardware provides full PCcontrol, real-time live MCA display, fast data transfer of single and multiplespectra to the PC, and full ORTEC CONNECTIONS network support. Multiple spectra may be block-transferred from the instrument controller toexternal PCs by the use of Microsoft ActiveSync. Third party products suchSOTI “Pocket Controller Enterprise” may be used to implement the 802.11wireless feature to provide remote wireless control of the completeinstrument.

Mobile MCB ServerThe Mobile MCB Server software application enables any ORTEC portableinstrument installed with a PDA to communicate wirelessly with ORTECsoftware applications such as MAESTRO, GammaVision, andDetective-Remote. The Mobile MCB Server acts like a wireless version ofthe USB connection, allowing users to control and monitor any portablespectrometer through a wireless network. Users can develop their own applications through the use of the optionalA11 tool kit.

Page 11: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

11

Detective-EX/DX-100T

Ordering Information

ModelLargeHPGe

NeutronDetector

Docking StationPower Supply

Power AdapterCharger (PAC) MAESTRO Software Transport Case

DETEX-100T-GPDETEX-100T-PKG-2DETEX-100T-PAC-GPDETEX-100T-PAC-PKG2

••••

••••

••

••

DETDX-100T-GPDETDX-100T-PKG-2DETDX-100T-PAC-GPDETDX-100T-PAC-PKG2

••••

••

••

Detective UpgradesA range of performance, usability, and reliability upgrades are available for all existing ORTEC Detectives including full warranty upgradeoptions. Contact [email protected] for details.

DET-SW-UPGUpgrade to complete Detective-Pro PDA Software Application package.

Page 12: Detective-EX-100T and Detective-DX-100T - ortec … · Hundreds are being used world wide by (among ... HPGe detector and by an internal compensated GM tube. The dose ... operator

Specifications subject to change031517

Detective-EX/DX-100T