PLAN VIEW ( 1:20 ) DETAIL E ( 1 : 10 ) FRONT VIEW ( 1:20 ) SECTION A-A ( 1:20 ) FOOTINGS LAYOUT SECTION B-B ( 1:20 ) SUMMER POSITION SECTION-C ( 1:20 ) WINTER POSITION SECTION D-D ( 1:5 ) SWIVEL BRACKET REV. SIZE DRAWING TITLE MODELLED DATE CHECKED APPROVED CLIENT: C DRAXCEL PTY.LTD OWNS THE COPYRIGHT TO THIS DRAWING WHICH IS ITS EXCLUSIVE PROPERTY AND WHICH IS SUPPLIED IN CONFIDENCE AND WHICH MUST NOT BE USED FOR ANY PURPOSE OTHER THAN THAT EXPRESSLY PERMITTED IN WRITING BY THE OWNERS AND MUST NOT BE DISCLOSED OR PRODUCED WITHOUT PERMISSION FROM THE OWNERS IN WRITING. THIS DRAWING MUST BE RETURNED TO THE OWNERS WHEN THE PURPOSE FOR WHICH IT IS SUPPLIED HAS CEASED. GENERAL TOLERANCE: UNLESS OTHERWISE STATED 0.000 0.00 0.0 OVER 0 TO 500 OVER 500 TO 5000 OVER 5000 TO 10000 ANGLES SURFACE FINISH: ±0.005 ±0.05 ±0.5 ±1 ±2 ±5 ±1° FABRICATIONS MACHINING 6.3 3.2 DATE DATE DATE ALL DIMENSIONS IN MILLIMETERS DO NOT SCALE - IF IN DOUBT ASK AS1100 DRAWING No. DRAXCEL JOB DRAWN A1 SOLAR PANEL FRAME SAMPLE SJI Stephen E:\Projects\Inventor\Solar Panel Frame_2\design 2\north_1.ipt 10 Sample_Main_10 E:\Projects\Inventor\Solar Panel Frame_2\idw\Sample_Main_10.dwg 24/10/2002 31/03/2014 0 LAYOUT E A A B B C C D D DRAXCEL DRAUGHTING SERVICES 85 LAVELLE ST. BATHURST NSW 2795. MOBILE: 0425244240 EMAIL: [email protected] 0 CONSTRUCTION ISSUE 31/03/2014 REVISION HISTORY REV DESCRIPTION DATE APPROVED ISSUE FOR CONSTRUCTION NOTES:- 1. SEE SUGGESTED CONSTRUCTION NOTES FRONT PAGE FOR CONSTRUCTION METHODS. 2. COLD GALVANISE ALL STEEL COMPONENTS FOR WEATHER PROOFING. TRUE NORTH MAGNETIC NORTH 15 ° 255.5 682.5 1094 1988 2188 1988 1094 2188 6164 8352 1094 1094 450 Ø 150 850 1000 152 40 900 30° 900 62° SEE MAIN POST DRAWING FOR DETAILS SEE FRONT POST DRAWING FOR DETAILS SEE REAR POST DRAWING FOR DETAILS SEE SOLAR PANEL FRAME DRAWING FOR DETAILS SEE REAR POST FOR LATCH DETAILS 225 DIA. TREATED TIMBER POST GROUND LEVEL (TYP.) CONCRETE (TYP.) 1652 S O L A R P ANE L S T OP F ACE 3984 SOLAR PANEL FRAME 93 99 99 93 3984 SOLAR PANEL FRAME 2 GAP TYPICAL n450

DETAIL E ( 1 : 10 ) PLAN VIEW ( 1:20 ) B C - Draxcel · 2016. 10. 14. · DRAWN AS1100 DRAXCEL JOBDRAWING No. A1 SOLAR PANEL FRAME SAMPLE SJI Stephen E:\Projects\Inventor\Solar Panel

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DETAIL E ( 1 : 10 ) PLAN VIEW ( 1:20 ) B C - Draxcel · 2016. 10. 14. · DRAWN AS1100 DRAXCEL JOBDRAWING No. A1 SOLAR PANEL FRAME SAMPLE SJI Stephen E:\Projects\Inventor\Solar Panel

PLAN VIEW ( 1:20 )

DETAIL E ( 1 : 10 )

FRONT VIEW ( 1:20 )

SECTION A-A ( 1:20 )FOOTINGS LAYOUT

SECTION B-B ( 1:20 )SUMMER POSITION

SECTION-C ( 1:20 )WINTER POSITION

SECTION D-D ( 1:5 )SWIVEL BRACKET

REV.SIZE

DRAWING TITLE

MODELLED DATE

CHECKED

APPROVED

CLIENT:C

DRAXCEL PTY.LTD OWNS THE COPYRIGHT TO THIS DRAWINGWHICH IS ITS EXCLUSIVE PROPERTY AND WHICH IS SUPPLIEDIN CONFIDENCE AND WHICH MUST NOT BE USED FOR ANYPURPOSE OTHER THAN THAT EXPRESSLY PERMITTED IN

WRITING BY THE OWNERS AND MUST NOT BE DISCLOSED ORPRODUCED WITHOUT PERMISSION FROM THE OWNERS INWRITING. THIS DRAWING MUST BE RETURNED TO THE

OWNERS WHEN THE PURPOSE FOR WHICH IT IS SUPPLIED HASCEASED.

GENERAL TOLERANCE:

UNLESS OTHERWISE STATED0.0000.000.0OVER 0 TO 500OVER 500 TO 5000OVER 5000 TO 10000ANGLES

SURFACE FINISH:

±0.005±0.05±0.5±1±2±5±1°

FABRICATIONS MACHINING

6.3 3.2DATE DATE

DATE

ALL DIMENSIONS IN MILLIMETERSDO NOT SCALE - IF IN DOUBT ASK

AS1100 DRAWING No.DRAXCEL JOBDRAWN

A1

SOLAR PANEL FRAME

SAMPLE

SJI

Stephen

E:\Projects\Inventor\Solar Panel Frame_2\design 2\north_1.ipt

10 Sample_Main_10

E:\Projects\Inventor\Solar Panel Frame_2\idw\Sample_Main_10.dwg

24/10/2002

31/03/2014

0

LAYOUT

E

A A

B

B

C

C

D D

DRAXCEL DRAUGHTING SERVICES

85 LAVELLE ST.BATHURST NSW 2795.

MOBILE: 0425244240EMAIL: [email protected]

0 CONSTRUCTION ISSUE 31/03/2014

REVISION HISTORY

REV DESCRIPTION DATE APPROVED

ISSUE FOR CONSTRUCTION

NOTES:-

1. SEE SUGGESTED CONSTRUCTION NOTES FRONT PAGE FOR CONSTRUCTION METHODS.2. COLD GALVANISE ALL STEEL COMPONENTS FOR WEATHER PROOFING.

TRUE NORTH

MAGNETIC NORTH

15°

255.5

682.5

1094 1988 2188 1988 1094

2188

6164

8352

10941094

450Ø

150

850

1000

152

40

900

30°

900

62°

SEE MAIN POST DRAWING FOR DETAILS

SEE FRONT POST DRAWING FOR DETAILS

SEE REAR POST DRAWING FOR DETAILS

SEE SOLAR PANEL FRAME DRAWING FOR DETAILS

SEE REAR POSTFOR LATCH DETAILS

225 DIA. TREATEDTIMBER POST

GROUND LEVEL (TYP.)

CONCRETE (TYP.)

1652 SOLAR PANELS TOP FACE

3984 SOLAR PANEL FRAME93 99 99 933984 SOLAR PANEL FRAME

2 GAP TYPICAL

n450