MODEL NUMBER NOMENCLATURE
Position 1-4 5 6-8 9 10 11 12 13 14 15 16
Description 30RA P 010 6 D - 0 6 0 0 0
Air Cooled AquaSnapChiller
Refrigeration Type
P = Puron
Nominal Capacity
010, 011, 015, 016, 018, 020, 025, 030, 035, 040, 045, 050,
055, 060, 070, 080, 090, 100, 115, 130, 150
Voltage Options
1 = 575-3-602 = 380-3-605 = 208/230-3-606 = 460-3-60
Condenser Coil / Low Sound Options
Revision Level
Hydronic System Options
Ambient / Capacity Control / SCCROptions
Electrical Options
Controls / Communication Options
Packaging / Security Options
30233001
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
2/14
MODEL NUMBER NOMENCLATURE DEFINITION
Condenser Coil / Low Sound Options (Position 10)
0 = Al coil, value sound fan1 = CU coil, value sound fan2 = Pre-coat Al coil, value sound fan3 = E-coat Al coil, value sound fan4 = E-coat CU coil, value sound fan
Revision level (Position 11)
A = Current revision level
Hydronic System (Position 12)
30 RAP 010-0600 = No Pump
2 = Single Pump, 1.5 Hp
3 = Single Pump, 3 Hp (SSN0211Q)4 = Single Pump, 3 Hp (PSN0211Q)
5 = Single Pump, 5 Hp6 = Single Pump, 5 Hp High Head7 = Single Pump, 7.5 HpZ = Single Pump, 10 Hp
9 = Dual Pump, 1.5 HpB = Dual Pump, 2 Hp (PSN0211Q)
C = Dual Pump, 3 Hp (PSN0211Q)
D = Dual Pump, 5 HpF = Dual Pump, 5 Hp High HeadG = Dual Pump, 7.5 HpH = Dual Pump, 10 Hp
30 RAP 070-1500 = No Pump1 = Single Pump, 3 Hp2 = Single Pump, 5 Hp3 = Single Pump, 7.5 Hp4 = Single Pump, 10 Hp5 = Single Pump, 15 Hp6 = Dual Pump, 3 Hp7 = Dual Pump, 5 Hp8 = Dual Pump, 7.5 Hp9 = Dual Pump, 10 HpB = Dual Pump, 15 HpC = Single Pump, 3 Hp w/ VFD
D = Single Pump, 5 Hp w/ VFDF = Single Pump, 7.5 Hp w/ VFDG = Single Pump, 10 Hp w/ VFDH = Single Pump, 15 Hp w/ VFDJ = Dual Pump, 3 Hp w/ VFDK = Dual Pump, 5 Hp w/ VFDL = Dual Pump, 7.5 Hp w/ VFDM = Dual Pump, 10 Hp w/ VFDN = Dual Pump, 15 Hp w/ VFD
Ambient / Capacity Control / Interrupt Options (Position 13)
0 = Std Comp, Std Interrupt1 = Std Comp, Hot Gas Bypass, Std Interrupt2 = Digital Comp, Std Interrupt3 = Std Comp, High Interrupt4 = Std Comp, Hot Gas Bypass, High Interrupt5 = Digital Comp, High Interrupt6 = Low Ambient, Std Comp, Std Interrupt7 = Low Ambient, Std Comp, Hot Gas Bypass, Std Interrupt8 = Low Ambient, Digital Comp, Std Interrupt9 = Low Ambient, Std Comp, High Interrupt
B = Low Ambient, Std Comp, Hot Gas Bypass, High InterruptC = Low Ambient, Digital Comp, High Interrupt
D = Std Comp, Std Interrupt, Suction Service ValvesF = Std Comp, Hot Gas Bypass, Std Interrupt, Suction Service ValvesG = Digital Comp, Std Interrupt, Suction Service ValvesH = Std Comp, High Interrupt, Suction Service ValvesJ = Std Comp, Hot Gas Bypass, High Interrupt, Suction Service ValvesK = Digital Comp, High Interrupt, Suction Service ValvesL = Low Ambient, Std Comp, Std Interrupt, Suction Service Valves
M = Low Ambient, Std Comp, Hot Gas Bypass, Std Interrupt, Suction Service ValvesN = Low Ambient, Digital Comp, Std Interrupt, Suction Service ValvesP = Low Ambient, Std Comp, High Interrupt , Suction Service ValvesQ = Low Ambient, Std Comp, Hot Gas Bypass, High Interrupt, Suction Service ValvesR = Low Ambient, Digital Comp, High Interrupt, Suction Service Valves
Electrical Options (Position 14)
30 RAP 010-0600 = No Disconnect, No Cooler Heater1 = No Disconnect, Cooler HeaterD = Non-Fused Disconnect, No Cooler HeaterF = Non-Fused Disconnect, Cooler Heater
30 RAP 070-1500 = Single Point, Disconnect, No Cooler Heater1 = Single Point, No Disconnect, Cooler Heater
2 = Single Point, Non fused Disconnect, No Cooler Heater3 = Single Point, Non fused Disconnect, Cooler Heater4 = Dual Point, No Disconnect, No Cooler Heater5 = Dual Point, No Disconnect, Cooler Heater
Controls / Communications Options (Position 15)
0 = Std.1 = Std., BACnet Communication5 = EMM6 = EMM, BACnet CommunicationB = EMM, GFIC = EMM, GFI, BACnet CommunicationH = GFIJ = GFI, BACnet Communicaiton
Packaging/Security Options (Position 16)
0 = Std Packaging4 = Security Grilles/Hail Guards Only8 = Skid Only
D = Skid, Security Grilles/Hail GuardsJ = Skid, Top Crate, BagN = Skid, Top Crate, Bag, Security Grilles/Hail Guards
3023300
1 = Single Pump, 1 Hp
3 = Single Pump, 2 Hp (PSN0211Q)
4 = Single Pump, 3 Hp High Head (SSN0111Q)
B = Dual Pump, 3 Hp (SSN0211Q)
C = Dual Pump, 3 Hp High Head (SSN0111Q)
8 = Dual Pump, 1 Hp
5 = MCHX coil, value sound fan6 = MCHX E-coat coil, value sound fan
7 = Al coil, reduced sound fan8 = CU coil, reduced fan9 = Pre-coat Al coil, reduced sound fanB = E-coat Al coil, reduced sound fanC = E-coat CU coil, reduced sound fanD = MCHX coil, reduced sound fanF = MCHX E-coat coil, reduced sound fanJ = MCHX coil, low sound fan, compressor blanket(s)K = MCHX E-coat coil, low sound fan, compressor blanket(s)L = Al coil, low sound fan, compressor blanket(s)M = CU coil, low sound fan, compressor blanket(s)N = Pre-coat Al coil, low sound fan, compressor blanket(s)P = E-coat Al coil, low sound fan, compressor blanket(s)Q = E-coat CU coil, low sound fan, compressor blanket(s)
D = Green Speed, Std Comp, Std InterruptF = Green Speed, Std Comp, Hot Gas Bypass, Std InterruptG = Green Speed, Digital Comp, Std InterruptH = Green Speed, Std Comp, High InterruptJ = Green Speed, Std Comp, Hot Gas Bypass, High InterruptK = Green Speed, Digital Comp, High Interrupt
30 RAP 010-060
30 RAP 070-150
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
3/14
7/26/2019 despliegue del chiller 30RAP.pdf
4/14
22
29
22
29
12
23
6
16
12
25
15
17 26
18 26
14
27
28
27
28
7
5
9
8 19
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
5/14
309
309
328
327
324
325
348
326
321
322
323
3
4
69
70
71
72
73
311
309
310
291291
288
310
31
309
309
30
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
6/14
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
7/14
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
8/14
7/26/2019 despliegue del chiller 30RAP.pdf
9/14
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pa
7/26/2019 despliegue del chiller 30RAP.pdf
10/14
7/26/2019 despliegue del chiller 30RAP.pdf
11/14
302330
156
145146147148149
150151152153154
155
or163 165D
or164 165E
155
A
A
011
SECTION A - A(011) PIPING
141
137
139
140
143
142 138
165C
165F
165B
011
B
B
SECTION B - BTYP 8 PLCS
162
159
161
15
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pag
7/26/2019 despliegue del chiller 30RAP.pdf
12/14
302330
184
185
181
183182
GREENSPEED OPTION
(011-016) VFD WIRING
165G
DGT
GRILL ASSY MOUNTING DETAILS
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pag
7/26/2019 despliegue del chiller 30RAP.pdf
13/14
302330
145146147148149
150151152153154
155
or163 165Dor164 165E
155
016
165C
165F165B
016
B
B
SECTION B - B
TYP 4 PLCS
162
160
16
A
A
SECTION A - A
TYP 4 PLCS
162
159
161
odel/Sales Package: 30RAP0155.A.....
placement Components Division - Copyright Carrier Corporation Pag
7/26/2019 despliegue del chiller 30RAP.pdf
14/14
del 30RAP0155.A.....
scription AIR COOLED LIQUID CHILLER, 208/230-3-60
o detail)
odel/Sales Package: 30RAP0155.A.....