175
NextGen Advisory Committee (NAC) October 31, 2018 Meeting Summary Page 1 of 12 The NextGen Advisory Committee (NAC) was held October 31, 2018 at The MITRE Corporation in McLean, VA. The meeting discussions are summarized below. Reference the attachments for additional contextual information. List of attachments: Attachment 1: NAC Briefing Attachment 2: Attendance List Attachment 3: Public Statements Attachment 4: Approved NextGen Integration Working Group Rolling Plan 2019-2021 Final Report Opening of Meeting / Introduction of NAC Members Following administrative announcements, NAC Chairman Mr. Dave Bronczek, FedEx President and Chief Operating Officer (COO), opened the meeting and thanked Mr. Gregg Leonne, MITRE Vice President and Director, and MITRE for hosting the meeting. He then allowed NAC members/representatives around the table to introduce themselves (reference Attachment 2 for the complete attendance list). He added that future NAC meetings may return to a format with a longer agenda and dinner as has been done in the past. Official Statement of Designated Federal Officer (DFO) DFO Mr. Dan Elwell, Acting FAA Administrator, thanked Mr. Bronczek for his continued leadership as NAC chair. He echoed Mr. Bronczek’s sentiments thanking Mr. Leonne and MITRE for hosting. Mr. Elwell presented the Federal Advisory Committee Act (FACA) notice that governs public meetings. He added that there is a robust agenda that includes discussion on various items such as approving the NextGen Integration Working Group Rolling Plan 2019- 2021 Final Report, discussing new FAA taskings, and hearing from the Joint Analysis Team (JAT) and members of the public. Chairman’s Report Mr. Bronczek then provided the Chairman’s Report. To begin he called for a motion to certify the June 27, 2018 NAC meeting summary, which the NAC certified. Outcome: NAC Members passed a motion to certify the June 27, 2018 NAC Meeting Summary. Mr. Bronczek then announced Congress passing the FAA Reauthorization Act of 2018, which provides FAA authorization for the next five years. With its passing the FAA has the stability

Designing gable dormers t - Chief Architect Software · Designing gable dormers a spacing There are no hard-and-fast rules when it comes to dormer spacing, but start with ... width

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Designing gable dormers t - Chief Architect Software · Designing gable dormers a spacing There are no hard-and-fast rules when it comes to dormer spacing, but start with ... width

drawingboardl e s s o n s i n r e s i d e n t i a l d e s i g n

t here are many reasons you might want to put dormers on a roof. Perhaps you want greater access to daylight and views, or you need a little extra floor area. Or maybe you just think

that well-designed dormers add character to the house. When the primary goal is simply to add usable floor area while

preserving the lines of the main roof, a well-designed shed dormer

b y m i k e m a i n e s

Designing gable dormers

a spacingThere are no hard-and-fast rules when it comes to dormer spacing, but start with geometric patterns. For example, these three dormers happen to look best if evenly spread across the roof, but often the end dormers can be cheated a bit to the outside.

b roof slopeThe most conventional approach is to match the house’s roof slope. Here, that slope is 10-in-12. However, certain designs can support various slopes. When the dormer gable is inspired by a classical pediment, the pitch can be lower than the house roof, down to about 5-in-12.

a

e

is often the most practical solution. Large, horizontal shed dormers can significantly alter the original look of the home, however, so sometimes they’re best reserved for the back of the house. Large gable dormers are another solution, but their scale can quickly overwhelm the lower floors of the house, creating a top-heavy look. That said, should a dormer become large enough to be considered

C HeightWhen the house’s facade is tall, the dormers can be tall. Similarly, when the facade is short, the dormers can be short. However, height shouldn’t be a control in itself; rather, dormer height should always be driven by the size and scale of the windows to be used in the dormer.

d WidthIn her book Get Your House Right, Marianne Cusato suggests that the total width of a dormer be the same as that of the windows, including trim, on the main house below. This is a noble goal on straightforward, classical architecture. When adding a dormer to a house that does not

already have perfect classical details, you have to use the house as a reference. For example, on a bungalow, the dormer may look best with a little extra width to create more horizontal proportions.

e main-house referenceOn many houses, you can ignore the base of the house and focus simply on how well the dormers look on the roof. Because the dormers are in a different plane from the main-house wall, and because the roof eave provides a strong horizontal break, alignment with elements below is less important than the massing—that is, how the dormers “feel” on the roof.

b

C

d

6 ft. 15⁄8 in.

3 ft.

2 ft. 103⁄8 in.

8 in.

3 ft. 6 in. 3 ft. 6 in.

FINE HOMEBUILDING94

Page 2: Designing gable dormers t - Chief Architect Software · Designing gable dormers a spacing There are no hard-and-fast rules when it comes to dormer spacing, but start with ... width

l

km

C o n t i n U e ddrawingboard

F PlacementDormer placement is driven by many factors. Ideally, the window heads would align with any gable windows on each end of the house, and the ceiling in the dormer would be in plane with the other ceilings on the interior. From an exterior point of view, it’s a massing decision, and one best viewed in three dimensions. The “center of gravity” of the dormer—generally about two-thirds of the height of the cheek wall or half the overall height of the dormer—should land near the center of the roof. It’s OK to move it down a bit, but don’t move it higher.

g rake overhangWhen there is little or no rake overhang on the main house, detail the dormer to match. When the house has a larger rake overhang, reduce the overhang depth on the dormer by 25% to 50%, unless your intention is to draw attention to the dormer roof.

J Window sizeWhen sizing windows, choose units that reflect the first-floor windows but are scaled down by 10% to 25%. Keep the aspect ratio—the proportion of a window’s height to its width—the same, or make the windows slightly squat.

k egressIf any dormers are in a bedroom, remember that at least one window in each bedroom must meet code for egress. An egressable window has a distance from the floor no greater than

a cross gable, it will hold its own as a major element of the home’s design.

Appropriately scaled gable dormers bring in light while adding charm and interest to a large or plain roof. If designed well, they don’t com-pete with the lines of the main house; instead, they reinforce, complement, and enrich the house’s personality.

show restraintBy far, the most common mis-take people make when adding dormers is to design them too big. It’s understandable to max-imize the bang for your buck, but big dormers quickly com-promise the design, especially on smaller houses that have low eaves. To avoid this mis-take, think of the window as the main reason the dormer exists, and provide the mini-mum framework necessary around the window for struc-ture and insulation.

Here, I’ve designed gable dor-mers for a 1940s Cape—a style of home that often calls for the addition of dormers. The upper floor is to be finished as living space, so light, views, and egress are important factors driving its redesign. It’s always important to factor in egress when design-ing dormers because the size of many dormer windows won’t meet code for egress.

The house has low eaves, simple trim, and an asymmetri-cal front facade. It’s in a historic district, so the dormer additions need to be done carefully to enhance, not detract from, the home’s character.

Mike Maines is a designer and builder at EcoCor (ecocor.us) in Searsmont, Maine. Drawings by the author.

44 in., a minimum net-clear opening of 5.7 sq. ft., a minimum width of 20 in., and a minimum height of 24 in. This does not mean that an opening of 20 in. by 24 in. meets code. For example, a 20-in.-wide window has to be at least 42 in. high to meet the 5.7-sq.-ft. requirement. Also, because only half of a double-hung unit can be opened at a time, the net-clear opening is drastically diminished—down to 4.2 sq. ft. for the window in the drawing. Fortunately, manufacturers make casement windows that look like double-hung units for this purpose. For this project, such a casement window would have a net-clear opening of 8.4 sq. ft.

l gable materialIf the house details are simple, as they are here, matching the house siding is the conventional approach. If the house has more elaborate trim, or the dormers are particularly small, or if you want to add some visual interest, the gable and cheek walls can be finished and painted to match the trim. This makes the entire dormer a trim element.

m sill heightVisually, less is best. Holding the sill at least 2 in. off the roof keeps the sill above snow and ice and creates a vertical dam against blowing rain.

H trim sizeAs a rule, I scale the trim down by 10% to 25% compared to the roof trim on the main house.

i trim profilesThis house has simple eave trim: a vertical 1x8 with a gutter that creates a basic cornice. It doesn’t make sense to use gutters on dormers because any rain is directed into the gutters below. To create a different yet still appropriate cornice molding, use a flat fascia board set on a 40° to 45° angle.

F

g

H

i

41⁄2 in.

8 in.

31⁄2 in.

2 ft. 103⁄8 in.

1 ft. 11 in.

3 ft.

41⁄2 in.

2 ft. 5 in. 3 ft. 3 in.

4 ft.

3⁄4 in.

2 in.

5 in.

12

10

11⁄2 in.

J

3 ft. 6 in.

FINE HOMEBUILDING96