Design of Composite Steel-Concrete

Structures to Eurocode 4

- Some Basic Concepts

Chiew Sing-Ping

School of Civil and Environmental Engineering

Nanyang Technological University, SINGAPORE

10 April 2015

Page 2: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

2

Scope of Presentation

Design codes

Materials

Composite columns

Composite beams

Composite slabs

Page 3: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

3

Design Codes for Composite Structures

Eurocode 1

- for loadings

Eurocode 2

- for concrete properties and some

of the concrete related checks

(such as longitudinal shear)

Eurocode 3 (many Parts)

- for construction stage, design of

pure steel beam and profiled steel

sheeting

Eurocode 4 Part 1-1

- general rules of buildings

Eurocode 4 Part 1-2

- for the structural fire design

Effective 1 April 2015

BS 6399

- for loadings

BS 5950-1

- for construction stage, design of pure

beam

BS 5950-6

- for design of profiled steel sheeting

BS5950-3.1

- for design of composite beam

BS5950-4

- for design of composite slab

BS 5400-5

- for design of composite column

BS 5950-8

- for structural fire design

Superceded (valid till 31 March 2015)

Page 4: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

4

Design Safety Factors

Eurocodes British Standards

Load safety factors 1.35 Gk + 1.5 Qk 1.4 Gk + 1.6 Qk (BS5950)

1.2 Gk + 1.5 Qk (BS5400-5)

Material

safety

factors

Structural steel 1.0 1.0 (BS5950)

1.05 (BS5400-5)

Concrete 1.5 1.5

Reinforcement 1.15 1.15

Page 5: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

5

BS5950 EC4

Concrete Normal C30 – C50 C20/25 – C60/75

Light weight C25 – C40 LC20/22 – LC60/66

Structural steel ≤ 355 N/mm2 ≤ 460 N/mm2

Concrete and steel strengths in EC4 and BS5950

Cube strength Cylinder strength / Cube strength

Material Strength

The ranges are narrower compared to EC2 (C12/15 – C90/105) and EC3

(≤ 690 N/mm2) because of more limited knowledge and experience in

composite members with very high concrete and steel strengths.

Page 6: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

Concrete Strength

6

One of the most noticeable differences in Eurocodes is the way

concrete strength is specified throughout.

In British Standards,

the cube strength fcu is used.

In Eurocodes,

the cylinder strength fck is used.

Page 7: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

7

Will different

strength gives

different

resistance ?

BS

Cube strength

25 N/mm2

EC

Cylinder strength

20 N/mm2

Converting from

the concrete

strength to

equivalent plastic

stress block

BS: 0.45 fcu = 0.45×25 = 11.25 N/mm2

EC: 0.85 fck/γc= 0.85×20/1.5 = 11.33 N/mm2

No difference!

Page 8: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

8

EC3 has additional ductility requirements compared to

BS5950 in terms of stress ratio, % elongation and strain

ratio.

Steel Strength

Normal strength steel

• fu/fy ≥ 1.10

• Elongation at failure not

less than 15%

• εu ≥ 15εy εy is the yield

stain

high strength steel

• fu/fy ≥ 1.05 (EC3-1-12)

• fu/fy ≥ 1.10 ( UK NA to EC3-1-12)

• Elongation at failure not less

than 10%

• εu ≥ 15 εy

Page 9: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

9

Problem Some product standards only have requirements on the nominal yield

and tensile strengths, or their minimum values. The stress ratio calculated

according to these nominal values cannot comply with the EC3 ductility

requirement. Also, % elongation cannot comply. Refer to BC1 for

guidance on minimal requirements and compliance under SS NA.

Standard Grade Nominal yield

strength (MPa)

Nominal tensile

strength (MPa) Stress ratio

AS 1397 G500 500 520 1.04

G550 550 550 1.00

AS 1595 CA 500 500 510 1.02

EN 10326 S550GD 550 560 1.02

ISO 4997 CH550 550 550 1.00

AS 1397: Steel sheet and strip – hot-dip zinc-coated or aluminium/zinc-coated

AS 1595: Cold-rolled, unalloyed, steel sheet and strip

EN 10326: Continuously hot-dip coated strip and sheet of structural steels

ISO 4997: Cold-reduced carbon steel sheet of structural quality

Page 10: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

10

Profiled Steel Sheeting

Most types of profiled steel sheeting are manufactured from

G500/G550 steel in accordance with AS1397.

Page 11: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

11

Headed Stud Shear Connector

In BS 5950, the resistances of headed studs in solid slab

are given for various combinations of height, diameter and

concrete strength but the physics behind these numbers are

not explained.

In EC4, the resistance is expressed in two equations

governed by the strength of concrete and steel.

Page 12: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

12

Dimensions of headed stud shear

connectors

Characteristic strength of

concrete (fcu)

Nominal shank

diameter

(mm)

Nominal

height

(mm)

As-welded

height

(mm)

25

N/mm2

30

N/mm2

35

N/mm2

≥ 40

N/mm2

25 100 95 146 154 161 168

22 100 95 119 126 132 139

19 100 95 95 100 104 109

19 75 70 82 87 91 96

16 75 70 70 74 78 82

13 65 60 44 47 49 52

Characteristic Resistance Qk of Headed Studs in

Normal Concrete (BS 5950-3.1 Table 5)

Page 13: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

13

2

uRd

V

0.8 4f dP

2

ck cm

Rd

V

0.29 d f EP

Design Resistance of Headed Studs in Solid

Concrete Slab (EC4)

EC4 calculates the resistance as the minimum of two equations,

shown here as (1) and (2).

12.0 sc

d

h

The two equations represent the 2 possible failure modes:

(1)

(2)

(i) failure in the shank of headed stud and (ii) failure in concrete.

Page 14: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

14

Push-out Test Specimen

Failure in the headed stud

Failure in concrete

concrete

crushes

steel failure

Page 15: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

15

Characteristic resistance of shear stud, PRk (kN)

Headed shear studs embedded

in solid concrete slab of

normal weight concrete

Characteristic strength of concrete (N/mm2)

25 30 35 40

BS5400: Part 5: 2005 90 100 104 109

BS5950: Part 3.1: 2010 95 100 104 109

EC4: Part 1.1: 2004 81.0 92.1 100.6 102.1

Comparison of Characteristic Resistances in

various Design Codes

Notes: Nominal shank diameter = 19mm

Nominal height = 100mm while as-welded height = 95mm

EC4 leads to a 17% reduction of the characteristic resistance.

Page 16: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

16

Characteristic Resistance of Stud (EC4 and BS5950)

0

20

40

60

80

100

120

140

160

25 30 35 40 45 50

BS (d=22mm, h=100mm)

EC (d=22mm, h=100mm)

BS (d=19mm,h=100mm)

EC (d=19mm, h=100mm)

BS ( d=16mm, h=75mm)

EC (d=16mm, h=75mm)

PR

k (

kN

)

Concrete strength (N/mm2)

Note: the differences are larger for smaller stud diameters

Page 17: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

17

In general, the resistance of headed stud shear connectors

determined by EC4 is lower than BS5950.

more headed studs are needed in EC4 design !

Page 18: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

18

Design Resistance of Headed Studs in

Composite Slab

The design resistance of headed stud connector in composite

slab with profiled steel sheeting is more complex than in a solid

slab. It is influenced by the following factors:

The direction of the ribs relative to direction of span of the

composite beam;

The mean breadth b0 and depth hp of profiled steel sheeting;

The diameter d and height hsc of the headed shear stud;

The number nr of the headed studs in one trough;

Whether or not a headed stud is central within a trough.

Page 19: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

Reduction Factor kt

Design shear resistance is taken as the resistance in a solid slab

multiplied by the reduction factor kt

b0

hsc

hp

hp/2

b0

hP hsc

maxt,

p

sc

p

0

r

t 17.0

kh

h

h

b

nk

EC4:

BS5950-3.1: The coefficient is 0.85 and 0.6 for re-entrant trough profiles

and 0.63 and 0.34 for open trough profiles

For the EC4 these values are about 17% lower than the BS for re-entrant

profiles, but about 40% higher than the BS for open trough profiles. 19

Page 20: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

Upper Limit kt,max for the Reduction Factor kt

profiled

steel

sheeting

Number of stud

connectors per

trough

Thickness t

of sheet

(mm)

EC4 BS 5950-3.1

Stud not exceeding

20mm in diameter and

welded through

profiled steel sheeting

Stud not

exceeding

19mm in

diameter

Re-entrant

trough

nr=1 ≤1.0

>1.0

0.85

1.0 1.0

nr=2 ≤1.0

>1.0

0.70

0.8 0.8

Open

trough

nr=1 ≤1.0

>1.0

0.85

1.0 0.82

nr=2 ≤1.0

>1.0

0.70

0.8 0.45

For open trough profiles, the reduction factor in EC4 ≥ BS5950

For re-entrant trough profiles, the reduction factor in EC4 ≤ BS5950

Generally, most profiled sheet sheeting is designed such that their limiting

value dominates, so the reduction factor is independent of the geometry

20

Page 21: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

21

Characteristic resistance of shear stud, PRk (kN)

Headed shear studs in

composite slab with profiled

steel sheeting

Characteristic strength of concrete fcu

(N/mm2)

25 30 35 40

BS5950: Part 3:

2010

Re-entrant 95 100 104 109

Open trough 77.9 82 85.3 89.4

EC4: Part 1.1: 2004 68.9 75.5 85.5 86.8

nr=1

Notes: Nominal shank diameter = 19mm

Nominal height = 100mm while as-welded height = 95mm

The resistance of shear stud in composite slab determined in EC4 is up

to 27% lower than that given in BS 5950.

Page 22: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

Application of Composite Column

22

Page 23: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

23

Kingposts (supporting the roof) which are part of the barrette

piles installed during the foundation stage

Top-Down Construction

Page 24: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

24

Installation of a kingpost into the barrette pile

Page 25: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

25

Excavation for starter

bars

Install starter bars

KingPost in column

Casting column head

Page 26: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

26

Column Design Approach

Cross section resistance (yielding)

Resistance to compression

Resistance to moment

Reduced moment resistance under compressive force, i.e.

interaction between compression and bending

Member buckling resistance

Axial buckling resistance

Reduced moment resistance under compressive force, i.e.

interaction between compression and bending

δ

F

e

LBA

GNIA

Fcr

Types of elastic analysis

and design

Page 27: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

27

Simplified Method (EC4 Clause 6.7.3.4)

Design Concepts

Axial

compression

Resistance of

member in

combined

compression

and bending

Design based on the

EC3 buckling curves

(similar to pure steel column)

Design based on second-order

analysis with equivalent member

Imperfection (simplified method)

Design based on second order

analysis with equivalent member

Imperfection (simplified method)

χ

e0

e0

Page 28: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

28

Axial Compression Resistance

Compression resistance of composite column

sdscdcydaRdpl, fAfAfAN

= + +

yk a/f ck c/f sk s/f

steel concrete reinforcement

Page 29: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

29

Axial Buckling Resistance

The buckling reduction factor

(EC3 approach)

0.1Rdpl,

Ed N

N

0.1

-

1

22

2

2.0-15.0

cr

Rkpl,

N

N

λ

a

b

1.0

0.0 1.0 2.0

x

Plastic resistance

Euler buckling

c

Page 30: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

30

Buckling Curve - EC3

Page 31: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

Buckling Curve – EC4

Cross-section Limits Axis of

buckling

Buckling curve

S235 - S460

Concrete encased section y-y b

z-z c

Partially concrete encased

section

y-y b

z-z c

Concrete filled circular and

rectangular hollow sections

ρs ≤ 3% any a

3% < ρs ≤ 6% any b

• For steel column, the buckling curve is related to steel section and steel

strength.

• For composite column, the buckling curve is related to the cross-section.

The strength of steel has little influence on the buckling curve.

31

Page 32: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

32

Design based on

EC3 buckling

curve

Design based on EC4

simplified approach -

second order analysis &

member imperfection

Buckling curve b

Member

imperfection L/200

Resistance of

axial

compression

N Rd (χ) = 4320 kN N Rd (e0) = 4108 kN

Comparison

NRd(X) / NRd(e0)

1.05

e0

NEd

NEd

Example - Comparison of Design Approach

Note: design based on the use of member imperfection e0 leads to

a maximum difference of 5% in comparison with design based on

the EC3 buckling curve approach.

Design data:

fy=355N/mm2, fck=25N/mm2, fsk=500N/mm2,

Cross-section: 350mm×350mm, steel section: 254×254 UC73.

Column length: 5.0m, 4 bars of 20mm diameter

Page 33: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

33

Design based on EC3

buckling curve approach

Design based on EC4

simplified approach

The maximum resistance can be

obtained by:

Second order effect factor k:

0.1

-

1

22

2

2.0-15.0

cr

Rkpl,

N

N

0pl,Rd Rd (e )

pl,Rd pm,Rd

-=

-

N N

N N

Rd( )N 0Rd (e )N

0Rd(e ) 0 M pl,Rd =kN e M

Rd( ) pl,Rd=N N

2

ef,II

cr,eff 2

cr

( )=

EIN

L

N

M Mpl,Rd

NRd(e0)

Npl,Rd

Npm,Rd

μMpl,Rd

Ed,max M pl,RdM M

0Ed,max Rd(e ) 0=M k N e

0Rd (e ) cr,eff

1=

1- /k

N N

Easier approach !

Tedious approach !

Example - Comparison of Design Approach

Page 34: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

34

Resistance of Members in combined

Compression and Bending

The EC3 buckling curve approach can be adopted for

composite column under axial compression, however, this

approach is not suitable for composite column subjected to

axial compression and bending moment.

In design of slender RC column, an accidental eccentricity of

the axial load in the column is introduced to calculate the

maximum moment at mid-height of the column.

Similar to slender RC column, equivalent initial bow

imperfections (member imperfections) are used in the design of

composite column for simplification.

Page 35: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

35

Bending Moment due to Member Imperfection

e0

NEd

NEd

For the member imperfection e0 caused by the

design axial load NEd on a composite column,

there will be a bending moment of NEde0.

The design bending moment for the composite

column length considered both second-order

effects of end moment and imperfection is given

by:

k1, k2 are the factors of second order effects

0Ed2Ed1Ed.max eNkMkM

Ed cr,eff

=1- /

kN N

related to end moment ratio

Page 36: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

36

Cross-section Axis of

buckling

Buckling

curve

Member

imperfection (e0)

Concrete encased section

y-y b L/200

z-z c L/150

Partially concrete encased

Section

y-y b L/200

z-z c L/150

Circular and rectangular

hollow section

y-y a L/300

z-z b L/200

Circular hollow section with

additional I-section

y-y b L/200

z-z b L/200

Partially encased H section

with crossed H section

any b L/200

z

y

y

z

z

y

z y

y z

Member Imperfections for Composite Column

Page 37: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

37

Compared to EC4 (1994), the simplified method for

composite columns in EC4 (2004) was improved using

second order analysis and equivalent member (initial bow)

imperfection which takes into account the effects of residual

stresses and geometrical imperfections.

Introducing initial bow imperfections into the simplified

method for composite columns, the scope of the simplified

method can be extended to sway frames.

Improvement in the Design of Column in

Combined Compression and Bending

Page 38: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

38

Ed, max

M

d pl,Rd

M

M

(a) EC4: 1994

The member imperfection can be taken

into account in the global analysis and

hence it is not necessary to allow for

the imperfection in the analysis of the

interaction curve.

Ed

M

pl,Rd

M

M

The influence of imperfection is taken

into account indirectly in the interaction

curve. The factor μd is reduced by a

relevant amount to account for the

moment due to the member

imperfection.

1 Ed 2 Ed 0k M k N e

1 Edk M

(b) EC4: 2004

Page 39: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

39

Design of Composite Beam

The concrete slab works best in compression while the steel section

works best in tension; hence, a large moment resistance is generated

as a force couple.

Resistance mobilization in both the concrete slab and the steel section

is limited by the shear connection along the concrete interface.

Nc,f

Np

Npl,a

Page 40: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

40

Failure Modes of Composite Beam

I-I resistance to sagging moment and vertical shear

II-II resistance to hogging moment and shear and M-V interaction

III-III shear connection @ the steel – concrete interface

IV-IV lateral torsional buckling

V-V Longitudinal shear of the concrete flange

IV

IV

Page 41: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

41

Lateral Torsional Buckling Resistance

In BS5950-3.1, no equation is provided to calculate the

lateral torsional buckling resistance of continuous composite

beam under hogging moment over the internal support.

When checking LTB, the methods given in BS5950-1

(design of steel beam) is supposed to be used.

In EC4, the restraint of slab is taken into account compared

with steel beam in EC3.

Page 42: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

42

b b xM p S

LT2

LT LT LT

11

Rk

LT

cr

M

M

1/2

2 2

cr c 4 a at s a afz/ /M k C L G I k L E I

BS5950-3.1 EC4

RdLTRdb, MM

Where pb is determined by λTB

TB t t=n uv

0.5

s

t 2 2

s

4 /=

1+ 2 / +0.05 /

a hv

a h x

With:

EC4 EC3 BS5950-3.1 EC4/BS

Ratio

EC4/EC3

Ratio

Lateral-torsional

buckling 546 kNm 531 kNm 479 kNm 1.14 1.03

(EC4)

0.522

cr 1 2 2+w cr Tz

cr z z

I L GIEIM C

L I EI

(EC3)

Page 43: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

Inverted- U frame ABCD resisting lateral-torsional buckling

Elastic Critical Moment

43

In this approach, the elastic critical moment Mcr is determined using the

so-called “continuous inverted U-frame model”.

The model given in EC4 takes into account the lateral displacement of the

bottom flange causing bending of the steel web and the rotation of the top

flange that is resisted by bending of the concrete slab.

1/2

2 2

cr c 4 a at s a afz/ /M k C L G I k L E I

Page 44: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

44

Composite Slab

Possible modes of failure: Shear failure at end support

Moment failure near mid-span region

Debonding within longitudinal shear span along the interface between concrete slab and decking, i.e. shear bond failure critical

Re-entrant

Trapezoidal Open Trough (Trapezoidal)

Page 45: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

45

How can concrete “stick” to profiled sheeting after bending?

How reliable is the shear bond along the interface between

concrete and profiled sheeting ? • Surface bonding due to chemical reaction

- non ductile failure, hence not so reliable.

• Mechanical interlocking due to indentations or

embossments in the profiled sheeting or end anchorage

- ductile failure with rational provision, hence more

reliable.

Longitudinal Shear

Page 46: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

46

Longitudinal Shear

End slip

Cracking

Test setup

Page 47: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

47

• EC4:

p p

l,Rd

vs s

bd mAV k

bL

• BS5950-4:

r ps ss r cu

s v1.25

m AB dV k f

B L

m-k Method

m= 172.45

k= 0.2491

m= 163.26

k= 0.0312

Concrete

strength

Page 48: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

48

EC4 BS5950-4

Short span Long span Short span Long span

m 172.5 163.3

k 0.2491 0.0312

Shear-bond

resistance

Vl,Rd (kN)

79.3 60.1 74.3 56.2

Comparison of Longitudinal Shear

BS5950 provides a more conservative value for longitudinal shear resistance

Test Short span 81.2 kN Long span 61.6 kN

Page 49: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

49

Vertical Shear

1/3

v,Rd Rd,c 1 ck 1 pc w p100V C k f k b d

v,Rd,min min 1 cp w pV v k b d

BS 5950-4 EC4

v b s cV b d v

1/3 1/31/4

s cuc

m v

1000.79 400=

25

A fv

b d d

3/2 1/2

min ck0.035v k f

BS 5950-4 EC4 Experiment

153.6 kN 107.8 kN 118.7kN

EC4 provides a more conservative value for vertical shear resistance

Page 50: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

50

Punching Shear

BS 5950-4 EC4

p s p cCritical perimeter -V D D v

1/3 1/31/4

s cuc

m v

1000.79 400=

25

A fv

b d d

3/2 1/2

min ck0.035v k f

BS 5950-4 EC4 Experiment

186 kN 139 kN 108kN

BS5950-4 provides a more conservative value for vertical shear resistance

p,Rd p p Rd

1/3

Rd Rd,c 1 ck min100

V C d v

v C k f v

p c p f p f p c2 2 2 2 2 2 2C h b h a h d h s p sCritical perimeter = 4 - +4 +4 length of load areaD D d

Page 51: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

51

Conclusions

1. Composite members with high strength steel (≥ S460) and

concrete (≥ C60/75) outside the scope of EC4. Can refer to

BCA/SSSS design guide for S550 steel and C90/105

concrete for CFT members.

2. Common grades of profiled steel sheeting cannot meet

EC3 ductility requirements in terms of stress ratio (fu/fy)

and %elongation after fracture. Design strength will have

to be downgraded. Refer to BC1 design recommendations.

3. The resistance of headed stud shear connectors is

generally lower in EC4 compared to BS5950; BC1 adopts

EC4 design resistance values.

4. For composite columns, the EC4 buckling curves are

different compared to EC3 due to contribution of concrete.

Unlike EC3, no special consideration for composite column

with S460 steel.

Page 52: Design of Composite Steel-Concrete Structures to Eurocode ...ssss.org.sg/~ssssorgs/images/stories/docs/workshop_10apr2015_1.pdf · 3 Design Codes for Composite Structures Eurocode

52

Conclusions

5. The simplified design approach using second order

analysis and equivalent member imperfection without any

need for member buckling resistance check is much

easier for composite column in combined compression

and bending moment. Approach is more similar to EC2

concrete column design.

6. EC4 provides guidance for lateral-torsional buckling check

for continuous composite beams taking into account the

beneficial effect provided by the concrete slab, i.e. the so-

called ‘ inverted U-frame method’.

7. EC4 provides clear guidance for testing & development of

composite slab system using profiled steel sheeting.

Existing ‘m’ and ‘k’ values from BS5950 cannot be used

directly in EC4 composite slab design.