Design Criteria and
Nonstandard Features
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-i
Tables Critical Design Elements: VWE Slip Ramp HAN1 – Entrance .................................................................. C-1 Critical Design Elements: VWE Slip Ramp JAN1 – Entrance from NB Service Road to NB VWE .......... C-2 Critical Design Elements: VWE Slip Ramp JAN2 – Exit from NB VWE to NB Service Road ................... C-3 Critical Design Elements: VWE Slip Ramp LIBN1 – Entrance ................................................................. C-4 Critical Design Elements: VWE Slip Ramp LIBN2 – Exit .......................................................................... C-5 Critical Design Elements: VWE Slip Ramp LINN1 – Entrance ................................................................. C-6 Critical Design Elements: VWE Slip Ramp LINN2 – Exit .......................................................................... C-7 Critical Design Elements: VWE Slip Ramp RBN1 – Entrance .................................................................. C-8 Critical Design Elements: VWE Slip Ramp RBN2 – Exit .......................................................................... C-9 Critical Design Elements: VWE Slip Ramp CDN2 – Exit from NB VWE North of Belt Parkway ............ C-10 Critical Design Elements: VWE Slip Ramp CDN1 – Entrance from NB C-D Road to NB VWE ............. C-11 Critical Design Elements: VWE Slip Ramp NCN1 – Entrance ................................................................ C-12 Critical Design Elements: VWE Loop Ramp NCN2 – Exit ...................................................................... C-13 Critical Design Elements: VWE Loop Ramp NEN1 – Entrance .............................................................. C-14 Critical Design Elements: VWE Slip Ramp NEN2 – Exit ........................................................................ C-15 Critical Design Elements: VWE Slip Ramp FCN1 – Entrance ................................................................ C-16 Critical Design Elements: VWE Slip Ramp MSS2 – Exit from Main Street to C-D Road Southbound... C-17 Critical Design Elements: VWE Slip Ramp MSS1 – Entrance from C-D Road Southbound .................. C-18 Critical Design Elements: VWE Slip Ramp HAS2 – Exit ........................................................................ C-19 Critical Design Elements: VWE Slip Ramp AAS2 – Exit ......................................................................... C-20 Critical Design Elements: VWE Slip Ramp R101S2 – Exit ..................................................................... C-21 Critical Design Elements: VWE Slip Ramp R101S1 – Entrance ............................................................ C-22 Critical Design Elements: VWE Slip Ramp LINS2 – Exit ........................................................................ C-23 Critical Design Elements: VWE Slip Ramp LINS1 – Entrance ............................................................... C-24 Critical Design Elements: VWE Slip Ramp RBS2 – Exit ........................................................................ C-25 Critical Design Elements: VWE Slip Ramp RBS1 – Entrance ................................................................ C-26 Critical Design Elements: VWE Slip Ramp NCS2 – Exit ........................................................................ C-27 Critical Design Elements: VWE Loop Ramp NCS1 – Entrance .............................................................. C-28 Critical Design Elements: VWE Slip Ramp SB: Exit Ramp to Nassau Expressway (Two Lanes) ......... C-29 Critical Design Elements: VWE Slip Ramp SB: Exit Ramp to Nassau Expressway (Three Lanes) ....... C-30 Critical Design Elements: VWE Loop Ramp NES1 – Entrance .............................................................. C-31 Critical Design Elements: VWE Slip Ramp BPW1 – Entrance ............................................................... C-32
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-1
Critical Design Elements: VWE Slip Ramp HAN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
HAN1 is a slip ramp connecting North Service Rd (at Hillside Avenue) to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 7.8% & PM: 3.5% Terrain: Rolling ADT: 15318 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
12 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 0.5 feet * Right: 3.75 feet
(minimum)*
Left: 4 feet (minimum) Right: 2.75 feet (minimum)*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 1988 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical) 200 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum)
V-SSD: 328 feet (minimum)
7 Maximum Grade 7% (HDM Section 2.7.5.3 G Exhibit 2-10a) 7% (maximum) 7% (maximum)
8 Cross Slope 1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a) 2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2)
14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-2
Critical Design Elements: VWE Slip Ramp JAN1 – Entrance from NB Service Road to NB VWE
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
JAN1 is a slip ramp connecting North Service Road (btw Archer Ave and Jamaica Ave) to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) N/A 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)2
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
N/A 15 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a) N/A
Left: Varies 2 feet to 3 feet* Right: Varies 0.5 feet to 5
feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D, Exhibit 2-10a) N/A 5258 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) N/A 8%
6 Stopping Sight Distance (Horizontal & Vertical) 200 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) N/A H-SSD:200 feet (minimum) V-SSD: 215 feet (minimum)
7 Maximum Grade 7% (HDM Section 2.7.5.3 G Exhibit 2-10a) N/A 7% (maximum)
8 Cross Slope 1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a) N/A 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) N/A 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 The existing ramp was relocated. This is a new ramp. 2 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-3
Critical Design Elements: VWE Slip Ramp JAN2 – Exit from NB VWE to NB Service Road
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
JAN2 is a slip ramp connecting Northbound VWE (btw Archer Ave and Jamaica Ave) to North Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) N/A 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)2
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
N/A 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a) N/A Left: 3 feet* Right: 4 feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) N/A 5,230 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) N/A 8%
6 Stopping Sight Distance (Horizontal & Vertical) 200 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) N/A H-SSD: 200 feet (minimum) V-SSD: 315 feet (minimum)
7 Maximum Grade 7% (HDM Section 2.7.5.3 G Exhibit 2-10a) N/A 7% (maximum)
8 Cross Slope 1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a) N/A 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) N/A 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 The existing ramp was relocated. This is a new ramp. 2 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-4
Critical Design Elements: VWE Slip Ramp LIBN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
LIBN1 is a slip ramp connecting North Service Road (at Liberty Ave) to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 5.9% & PM: 3.8% Terrain: Rolling ADT: 9394 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width
23 feet (for radii 200 to 300 feet)1 22 feet (for radii 300 to 1,000 feet)1
21 feet (for radii ≥ 1,000 feet)1 (HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
12 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 3.5 feet (minimum)*
Right: 3.0 feet (minimum)*
Left: Varies: 0.3 feet to 2 feet* Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 165 feet* 231 feet
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-5
Critical Design Elements: VWE Slip Ramp LIBN2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
LIBN2 is a slip ramp connecting Northbound VWE (at Liberty Ave) to North Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 5.2% & PM: 6.8% Terrain: Rolling ADT: 10045 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C) 12 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 1 foot (minimum)* Right: 6 feet
Left: 4 feet Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 5000 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical) 200 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) 200 feet (minimum)
H-SSD: 200 feet (minimum)
V-SSD: 200 feet (minimum)
7 Maximum Grade 7% (HDM Section 2.7.5.3 G Exhibit 2-10a) 7% (maximum) 7% (maximum)
8 Cross Slope 1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a) 2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2)
14 feet 0 inches (minimum)
14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-6
Critical Design Elements: VWE Slip Ramp LINN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: LINN1 is a slip ramp connecting
North Service Road (at Linden Blvd) to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 3.4% & PM: 2.1% Terrain: Rolling ADT: 7411 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
12 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 3 feet* Right: 6 feet
Left: 4 feet Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 2004 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-7
Critical Design Elements: VWE Slip Ramp LINN2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
LINN2 is a slip ramp connecting Northbound VWE (at Linden Blvd) to North Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 4.4% & PM: 3.6% Terrain: Rolling ADT: 9211 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C) 12 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: Varies: 1 foot to 3 feet*
Right: 6 feet
Left: 4 feet Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 231 feet (minimum) 1,515 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-8
Critical Design Elements: VWE Slip Ramp RBN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: RBN1 is a slip ramp connecting
North Service Road (at Rockaway Blvd) to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 12.1% & PM 6.3% Terrain: Rolling ADT: 5130 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C),
12 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: Varies: 2 feet (minimum)* Right: 6 feet
Left: 4 feet Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 231 feet (minimum) 2,200 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-9
Critical Design Elements: VWE Slip Ramp RBN2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: RBN2 is a slip ramp connecting C-D Road
Northbound (at Rockaway Blvd) to North Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 2.6 & PM 3.3% Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
15 feet 15 feet1
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 0 feet (minimum)2 Right: 0 feet (minimum)2 (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 0.5 feet Right: 6 feet
Left: 4 feet Right: 3 feet (minimum)
4 Horizontal Curve Radius 214 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
214 feet (minimum) 1,515 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) H-SSD: 176 feet* H-SSD: 200 feet (minimum) V-SSD: 215 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
5% 7%
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width; but not less than minimum travel lane width as under Case I (15 feet). 2 (HDM Section 2.7.5.3 C Exhibit 2-10a):
For urban turning roadways with curbing, and not a freeway ramp, no shoulder is required. A 2-foot curb offset is desirable.
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-10
Critical Design Elements: VWE Slip Ramp CDN2 – Exit from NB VWE North of Belt Parkway
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: CDN2 is a slip ramp connecting Northbound
VWE (at Belt Parkway) to C-D Road Northbound Functional Class: Urban Principal Arterial -
Interstate Project Type: Reconstruction Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 4.7% & PM: 4.7% Terrain: Rolling ADT: 9404 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
12.5 feet* 12 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 3 feet (minimum)* Right: 2 feet (minimum)*
Left: Varies 5 feet Right: 10 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 1,942 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 624 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-11
Critical Design Elements: VWE Slip Ramp CDN1 – Entrance from NB C-D Road to NB VWE
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: CDN1 is a slip ramp connecting C-D Road
Northbound (btw Rockaway Blvd and 133rd Ave) to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 10.4% & PM: 5.6% Terrain: Rolling ADT: 23278 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 40 mph (HDM Section 2.7.5.3 A) 40 mph 40 mph
2 Lane Width
27 feet traveled way2 (Two Lanes) (for radii ≥1,000 feet)
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
24 feet (Traveled Way Width)
27 feet (Traveled Way Width)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 6 feet Right: 2.5 feet (minimum)*
Left: 0.84 feet to 4 feet* Right: Varies: 2.5 feet to 6 feet*
4 Horizontal Curve Radius 444 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
485 feet (minimum) 3,314 feet (minimum)
5 Superelevation 8% (maximum) (HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical) 305 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) 305 feet (minimum) H-SSD: 305 feet (minimum) V-SSD: 570 feet (minimum)
7 Maximum Grade 6%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
6% (maximum) 6% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
1.5% (minimum) 2.5% (maximum)
1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 The Regional Traffic Engineer has concurred that the use of a design speed of 30 mph is consistent with the anticipated off-peak 85th percentile
speed within the range of functional class speeds for the terrain and volume. 2 (HDM Section 2.7.5.3 B Exhibit 2-9):
2 feet may be deducted from the traveled way width where either shoulder is 4 feet or wider. Additional width not needed when stabilized shoulders exist on both sides of the ramp.
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-12
Critical Design Elements: VWE Slip Ramp NCN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: NCN1 is a slip ramp connecting North Conduit
Ave to C-D Road Northbound Functional Class: Urban Principal Arterial -
Interstate Project Type:
Reconstruction Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 6.0% & PM: 3.7% Terrain: Rolling ADT: 33299 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 40 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 40 mph
2 Lane Width
30 feet traveled way2 (2 lanes) for radii 300 feet to 400 feet
29 feet traveled way2 (2 lanes) for radii 400 feet to 1,000 feet
27 feet traveled way2 (2 lanes) for radii ≥1,000 feet
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
25 feet (Traveled Way
Width)
29 feet (Traveled Way Width)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 0 feet (minimum)3 Right: 0 feet (minimum)3
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 3 feet (minimum)
Right: 2 feet (minimum)
Left: 1 feet (minimum) to 2 feet Right: 1 feet (minimum) to 6 feet
4 Horizontal Curve Radius 444 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 376 feet* 444 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-13
Critical Design Elements: VWE Loop Ramp NCN2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: NCN2 is a loop ramp connecting Northbound VWE
to North Conduit Ave Functional Class: Urban Principal Arterial -
Interstate Project Type: Reconstruction Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 3.1% & PM: 1.3% Terrain: Rolling ADT: 5028 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 25 mph (HDM Section 2.7.5.3 A) 15 mph* (posted) 25 mph
2 Lane Width
25 feet (for radii 100 feet to 150 feet)1 24 feet (for radii 150 feet to 200 feet)1 23 feet (for radii 200 feet to 300 feet)1
22 feet (for radii 300 to 1,000 feet)1 21 (feet for radii ≥ 1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
14 feet (minimum)* Varies: 14 feet to 18 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 7.5 feet (minimum) Right: 0.5 feet*
Left: 4 feet2 Right: Varies: 1.5 feet to 6 feet*
4 Horizontal Curve Radius 134 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 100 feet (minimum)* 110 feet (minimum)*
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-14
Critical Design Elements: VWE Loop Ramp NEN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name: NEN1 is a loop ramp connecting Nassau
Expressway to Northbound VWE Functional Class: Urban Principal Arterial -
Interstate Project Type: Reconstruction Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 3.8% & PM: 1.6% Terrain: Rolling ADT: 19585 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 25 mph (HDM Section 2.7.5.3 A) 25 mph 25 mph
2 Lane Width
23 feet (for radii 200 feet to 300 feet)1
22 feet (for radii 300 to 1,000 feet)1 21 feet (for radii ≥ 1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
14 feet* 16 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 14 feet Right: 0.5 feet*
Left: 10 feet (minimum)2 Right: Varies: 0.5 feet to 6 feet*
4 Horizontal Curve Radius 134 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
134 feet (minimum) 231 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-15
Critical Design Elements: VWE Slip Ramp NEN2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
NEN2 is a slip ramp connecting Northbound VWE to Nassau Expressway
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 9.8% & PM: 11.0% Terrain: Rolling ADT: 43172 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width 27 feet traveled way1 (2 lanes) for
radii ≥1,000 feet (HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
24 feet (Traveled Way Width)
25 feet1 (Traveled Way Width)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 1.5 feet (minimum)* Right: Varies: 2 feet to 10 feet
feet (minimum)
Left: Varies: 1.5 feet to 4 feet* Right: Varies: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 5,000 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 332 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
2 feet may be deducted from the traveled way width where either shoulder is 4 feet or wider. Additional width not needed when stabilized shoulders exist on both sides of the ramp.
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-16
Critical Design Elements: VWE Slip Ramp FCN1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
FCN1 is a slip ramp connecting Federal Circle to Northbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 12.5% & PM 10.5% Terrain: Rolling ADT: 9503 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Conditions
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 (design)
25 mph (posted) 30 mph
2 Lane Width
22 feet (for radii 500 to 1,000 feet)1 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
14 feet (minimum)* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 2 feet (minimum)* Right: 2 feet (minimum)*
Left: Varies 2 feet to 4 feet* Right: Varies 1 feet to 6 feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D
Exhibit 2-10a) 214 feet (minimum) 500 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-17
Critical Design Elements: VWE Slip Ramp MSS2 – Exit from Main Street to C-D Road Southbound
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
MSS2 is a slip ramp connecting Main Street to C-D Road Southbound
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 (design)
25 mph (posted) 30 mph
2 Lane Width
22 feet (for radii 500 to 1,000 feet)1 21feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
13 feet (minimum)* 11 feet (minimum)*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 0 feet (minimum)2 Right: 0 feet (minimum)2 (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 0 feet Right: 0 feet
Left: Varies: 0 feet to 4 feet Right: Varies: 0 feet to 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 500 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 305 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width; but not less than minimum travel lane width as under Case I (15 feet). 2 (HDM Section 2.7.5.3 C Exhibit 2-10a):
For urban turning roadways with curbing, and not a freeway ramp, no shoulder is required. A 2-foot curb offset is desirable.
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-18
Critical Design Elements: VWE Slip Ramp MSS1 – Entrance from C-D Road Southbound
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
MSS1 is a slip ramp connecting C-D Road Southbound to Southbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 7.3% & PM: 4.3% Terrain: Rolling ADT: 8744 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 (design)
25 mph (posted) 30 mph
2 Lane Width
22 feet (for radii 500 to 1,000 feet)1 21 feet (for radii ≥1,000 feet)
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
11 feet* 12 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 3 feet (minimum)* Right: 2 feet (minimum)*
Left: Varies: 1 foot to 2 feet* Right: Varies: 6 feet (minimum)
4 Horizontal Curve Radius 214 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
214 feet (minimum) 563 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 501 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-19
Critical Design Elements: VWE Slip Ramp HAS2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
HAS2 is a slip ramp connecting Southbound VWE to C-D Road SB (at Hillside Ave)
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 11.4% & PM: 10.0% Terrain: Rolling ADT: 9985 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width
22 feet traveled way (One Lane) (for radii 500 to 1,000 feet)1
21 feet traveled way (One Lane) (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
27 feet traveled way (Two Lanes)
for radii ≥1,000 feet (HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
One Lane Ramp: 11 feet (minimum)*
Two Lane Ramp: 10 feet
(minimum)*
One Lane Ramp:10.5 feet (minimum)*
Two Lane Ramp:10 feet
(minimum)*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 1 foot (minimum)* Right: 1 foot (minimum)*
Left: Varies 1 foot (minimum)* Right: Varies 1 foot (minimum)*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 862 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-20
Critical Design Elements: VWE Slip Ramp AAS2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
AAS2 is a slip ramp connecting Southbound VWE (Auxiliary lane exit between Jamaica Ave and LIRR) to South Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 11.0% & PM: 3.8% Terrain: Rolling ADT: 6782 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
12 feet* 12 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 0 feet (minimum)* Right: 1 foot (minimum)*
Left: 0 feet* Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) N/A (tangent) N/A (tangent)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 451 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-21
Critical Design Elements: VWE Slip Ramp R101S2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
R101S2 is a slip ramp connecting Southbound VWE (at 101st Ave) to South Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) N/A 30 mph
2 Lane Width
22 feet (for radii 500 to 1,000 feet)2 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
N/A 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
N/A Left: 4 feet Right: Varies: 1.5 feet to 3 feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) N/A 500 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) N/A 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) N/A H-SSD: 200 feet (minimum) V-SSD: 200 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
N/A 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
N/A 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) N/A 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 The existing ramp was relocated. This is a new ramp. 2 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-22
Critical Design Elements: VWE Slip Ramp R101S1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
R101S1 is a slip ramp connecting South Service Road (at 101st Ave) to Southbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) N/A 30 mph
2 Lane Width
22 feet traveled way (One Lane) (for radii 500 to 1,000 feet)4
21 feet traveled way (One Lane) (for radii ≥1,000 feet)4
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
29 feet traveled way2 (Two Lanes) for radii 500 feet to 1,000 feet
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
N/A
One Lane Ramp: Varies 12 feet to 15 feet*
(Traveled Way Width)
Two Lane Ramp: 24 feet* 3 (Traveled Way Width)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a) N/A
Left: 2 feet* Right: Varies: 3 feet to 6
feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) N/A 746 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) N/A 8%
6 Stopping Sight Distance (Horizontal & Vertical) 200 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) N/A H-SSD: 200 feet (minimum) V-SSD: 201 feet (minimum)
7 Maximum Grade 7% (HDM Section 2.7.5.3 G Exhibit 2-10a) N/A 7% (maximum)
8 Cross Slope 1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a) N/A 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) N/A 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 The existing ramp was relocated. This is a new ramp. 2 (HDM Section 2.7.5.3 B Exhibit 2-9):
2 feet may be deducted from the traveled way width where either shoulder is 4 feet or wider. Additional width not needed when stabilized shoulders exist on both sides of the ramp.
3 A 24-foot traveled way width is used since the 2-lane configuration exists only in the gore area. The merge to one lane begins at the start of the ramp proper.
4 (HDM Section 2.7.5.3 B Exhibit 2-9): Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-23
Critical Design Elements: VWE Slip Ramp LINS2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
LINS2 is a slip ramp connecting Southbound VWE (at Linden Blvd) to South Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 3.5% & PM: 2.8% Terrain: Rolling ADT: 10034 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30mph
(posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
14 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 2 feet (minimum)* Right: 4 feet (minimum)*
Left: 4 feet Right: Varies 3 feet to 6 feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 231 feet (minimum) 2000 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) 8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 303 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-24
Critical Design Elements: VWE Slip Ramp LINS1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
LINS1 is a slip ramp connecting South Service Road (at Linden Blvd) to Southbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 2.2% & PM: 1.2% Terrain: Rolling ADT: 9728 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
13 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 3 feet (minimum)* Right: 6 feet
Left: Varies 2 feet (minimum)* Right: Varies 2 feet (minimum)*
4 Horizontal Curve Radius 214 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
214 feet (minimum) 2,985 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 336 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
7% (maximum) 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-25
Critical Design Elements: VWE Slip Ramp RBS2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
RBS2 is a slip ramp connecting Southbound VWE (at Rockaway Blvd) to South Service Road
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 13.1% & PM: 4.3% Terrain: Rolling ADT: 6615 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph (posted) 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
13 feet* 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 4 feet Right: 5.5 feet (minimum)*
Left: 4 feet Right: Varies 3 feet to 6 feet*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 1,000 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-26
Critical Design Elements: VWE Slip Ramp RBS1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
RBS1 is a slip ramp connecting South Service Road (at Rockaway Blvd) to Southbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width 21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
15 feet 15 feet
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 2.5 feet (minimum)* Right: 6 feet
Left: 4 feet Right: 6 feet
4 Horizontal Curve Radius 214 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
214 feet (minimum) 1,515 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
8% 8%
6 Stopping Sight Distance (Horizontal & Vertical)
200 feet (HDM Section 2.7.5.3 F
Exhibit 2-10a) 200 feet (minimum) H-SSD: 200 feet (minimum) V-SSD: 222 feet (minimum)
7 Maximum Grade 7%
(HDM Section 2.7.5.3 G Exhibit 2-10a)
5.00% 7% (maximum)
8 Cross Slope
1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a)
2% 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) 14 feet 0 inches (minimum) 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Note: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet).
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-27
Critical Design Elements: VWE Slip Ramp NCS2 – Exit
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
NCS2 is a slip ramp connecting Southbound VWE to North Conduit Ave
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 7.1% & PM 2.2% Terrain: Rolling ADT: 28227 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 30 mph 30 mph
2 Lane Width
30 feet traveled way2 (Two Lanes) for radii ≥ 300 feet to 400 feet
29 feet traveled way2 (Two Lanes) for radii 400 feet to 1,000 feet
27 feet traveled way2 (Two Lanes) for radii ≥1,000 feet
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
24 feet (Traveled Way Width)
28 feet2 (Traveled Way Width)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 0.5 feet (minimum)* Right: 0.5 feet (minimum)*
Left: 0.5 feet (minimum)* Right: 0.5 feet (minimum)*
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 214 feet (minimum) 335 feet (minimum)
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-28
Critical Design Elements: VWE Loop Ramp NCS1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
NCS1 is a loop ramp connecting North Conduit Ave to Southbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 6.8% & PM: 9.6% Terrain: Rolling ADT: 3110 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 25 mph (HDM Section 2.7.5.3 A) 20 mph* 25 mph
2 Lane Width
27 feet (for radii 75 feet to 100 feet)1
25 feet (for radii 100 feet to 150 feet)1
24 feet (for radii 150 to 200 feet)1
23 feet (for radii 200 feet to 300 feet)1
22 feet (for radii 300 feet to 1,000 feet)1
21 feet (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
15 feet* Varies: 13 feet to 19 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a)
Left: 10 feet Right: 0.5 feet*
Left: 4 feet Right: Varies 1 foot to 6 feet*
4 Horizontal Curve Radius 134 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) 74 feet* 80 feet*
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-29
Critical Design Elements: VWE Slip Ramp SB: Exit Ramp to Nassau Expressway (Two Lanes)
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
Slip ramp connecting the SB VWE to Nassau Expressway (SB 40+30 to SB 74+50)
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 6.9% & PM: 4.6% Terrain: Rolling ADT: 41685 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition 1 Design Speed 60 mph 60 mph 60 mph
2 Lane Width
27 feet traveled way (Two Lanes) for radii ≥1,000 feet
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
36 feet (Traveled Way Width: 3
Lanes)
24 feet* (Traveled Way Width: 2 lanes)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 8 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 2 feet (SB 46+15 to SB 74+50)*;
Right: 0.5 feet (SB 42+15 to SB 51+05);
5 ft to 6 ft (SB 51+05 to SB 59+50)*
Left: N/A (SB 46+15 to SB 74+50);
6 feet (SB 74+50 to SB 40+30); Right: Varies 2 feet to 6 feet*
4 Horizontal Curve Radius 1,200 feet
(HDM, Section 2.7.1.1 D, Exhibit 2-2)
5665 feet (minimum) 4885 feet (minimum)
5 Superelevation 8%
(HDM, Section 2.7.1.1 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-30
Critical Design Elements: VWE Slip Ramp SB: Exit Ramp to Nassau Expressway (Three Lanes)
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
Slip ramp connecting the SB VWE to Nassau Expressway (SB 37+82 to SB 40+30)
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: AM: 6.9% & PM: 4.6% Terrain: Rolling ADT: 41685 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 40 mph (HDM Section 2.7.5.3 A) 40 mph 40 mph
2 Lane Width
29 feet traveled way (Two Lanes) for radii 400 feet to 1,000 feet
27 feet traveled way (Two Lanes) for radii ≥1,000 feet
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
45 feet (Traveled Way Width:
3 Lanes)
45 feet (Traveled Way Width: 3 lanes)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 0.5 foot (minimum)* Right: 3 feet (minimum)*
Left: Varies: 0.5 foot (minimum) to 6 feet*
Right: 3 feet*
4 Horizontal Curve Radius 444 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
522 feet 510 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
PIN X735.82 Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-31
Critical Design Elements: VWE Loop Ramp NES1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
NES1 is a loop ramp connecting Nassau Expressway to Southbound VWE
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction Design Classification (AASHTO Class): Interstate (Ramps)
% Trucks: AM: 25.2% & PM: 0.6% Terrain: Rolling ADT: 11708 Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) 35 mph (posted) 30 mph
2 Lane Width
22 feet (for radii 300 feet to 1,000 feet)1
21 feet (for radii ≥1,000 feet)1 (HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
20 feet 20 feet*
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum) (HDM Section 2.7.5.3 C
Exhibit 2-10a)
Left: 0.5 feet* Right: 0.5 feet*
Left: 0.5 feet to 1 foot* Right: Varies 0.5 feet
(minimum)*
4 Horizontal Curve Radius 214 feet
(HDM Section 2.7.5.3 D Exhibit 2-10a)
319 feet 319 feet (minimum)
5 Superelevation 8%
(HDM Section 2.7.5.3 E, Exhibit 2-1b)
Van Wyck Expressway Capacity and Access Improvements to JFK Airport Project FDR/FEIS PIN X735.82 APPENDIX C: DESIGN CRITERIA AND NONSTANDARD FEATURES
C-32
Critical Design Elements: VWE Slip Ramp BPW1 – Entrance
PIN: X735.82 NHS (Y/N): Yes Route No. & Name:
BPW1 is a slip ramp connecting the approach ramp to North Conduit to the Belt Parkway West
Functional Class: Urban Principal Arterial - Interstate
Project Type: Reconstruction
Design Classification (AASHTO Class):
Interstate (Ramps)
% Trucks: N/A Terrain: Rolling ADT: N/A Truck Access Rte.: Qualifying Highway
Element Standard Existing Condition Proposed Condition
1 Design Speed 30 mph (HDM Section 2.7.5.3 A) N/A 30 mph
2 Lane Width
21 feet traveled way (One Lane) (for radii ≥1,000 feet)1
(HDM Section 2.7.5.3 B Exhibit 2-9 Case II-C)
27 feet traveled way2 (Two Lanes) for radii 500 feet to 1,000 feet
(HDM Section 2.7.5.3 B Exhibit 2-9 Case III-C)
N/A
One Lane Ramp: Varies 16 feet to 27 feet
(Traveled Way Width)
Two Lane Ramp: 27 feet (Traveled Way Width)
3
Shoulder Width Left = Right (rolling & level) = Climbing Lane Shoulder =
Left: 4 feet (minimum) Right: 6 feet (minimum)
(HDM Section 2.7.5.3 C Exhibit 2-10a) N/A Left: 4 feet Right: 6 feet
4 Horizontal Curve Radius 214 feet (HDM Section 2.7.5.3 D Exhibit 2-10a) N/A 1050 feet
5 Superelevation 8% (HDM Section 2.7.5.3 E, Exhibit 2-1b) N/A 8%
6 Stopping Sight Distance (Horizontal & Vertical) 200 feet
(HDM Section 2.7.5.3 F Exhibit 2-10a) N/A H-SSD: 200 feet (minimum) V-SSD: 559 feet (minimum)
7 Maximum Grade 7% (HDM Section 2.7.5.3 G Exhibit 2-10a) N/A 7% (maximum)
8 Cross Slope 1.5% (minimum) 2.5% (maximum)
(HDM Section 2.7.5.3 H Exhibit 2-10a) N/A 1.5% (minimum) 2.5% (maximum)
9 Vertical Clearance 14 feet 0 inches (minimum) 14 feet 6 inches (desirable)
(BM, Section 2.4.1, Table 2-2) N/A 14 feet 0 inches (minimum)
10
Design Loading Structural Capacity Replace = Rehabilitation =
N/A N/A N/A
11 ADA Compliance N/A N/A N/A * Nonstandard Feature Notes: 1 (HDM Section 2.7.5.3 B Exhibit 2-9):
Deduct combined right and left shoulder width, but not less than minimum travel lane width as under Case 1 (15 feet). 2 (HDM Section 2.7.5.3 B Exhibit 2-9):
2 feet may be deducted from the traveled way width where either shoulder is 4 feet or wider. Additional width not needed when stabilized shoulders exist on both sides of the ramp.
Justification Number
Rev. 04/24/17
PIN: Route No. and Name:
Project Type:
Functional Class: Design Classification (AASHTO Class):
ADT: % Trucks: Terrain:
Type of Feature:
Statewide Accident Rate:
Cost to fully meet standards:
e.g., social, economic, and environmental
1 Use accidents per million vehicle miles (acc/mvm) for linear highway segments; use accidents per million entering vehicles (acc/meh) for intersections.
6. Other Factors
7. Proposed Treatment (i.e., recommendation)
3. Cost Estimates
4. Mitigation
Cost(s) for incremental improvements:
Anticipated accident rates, severity, and costs:
5. Compatibility with Adjacent Segments and Future Plans
e.g., increased superelevation and speed change lane length for a non-standard ramp radius
Is the Nonstandard Feature a contributing factor? From to
Existing Value:
Standard Value:
Exhibit 2-15Nonstandard Feature Justification- VWE Mainline and MUL
Latitude and Longitude (Linear Feature) FROM Lat: Long: TO Lat: Long:
Latitude and Longitude (Point Feature) Lat: Long:
Current Accident Rate1:
Recommended Speed - Proposed:
2. Accident Analysis
Location:
1. Description of Nonstandard Feature
Design Speed:
Recommended Speed - Existing:
Proposed Value:
I-678 – Van Wyck Expressway (Btwn Kew Gardens Interchange and JFK Airport)
Reconstruction
119790 (NB); 122210 (SB)
X735.82
NB PT 38+45.62 to PC 29+68.22
40.659545
1200 ft 60 mph
800 ft 50 mph
0.41 acc/mvm acc/mev 1.1
Yes No
No change is anticipated. Horizontal curve radius is not a contributing feature to the accident rate. Furthermore, the proposed horizontal curve radius is animprovement from the existing value.
$53 Million $25 Million
Construct curve with a radius of 847 ft which meets the minimum radius required for the posted speed of 50mph.Provide curve warning signs and advisory speed signs where warranted. See other sections of this form for detail regarding limitations on achieving thestandard or incorporating additional mitigation measures.
Improvement is compatible with future plans.
The proximity of several existing PANYNJ AirTrain piers limits the geometry between Federal Circle and Belt Parkway. The proposed horizontal alignmentaccommodates an increased roadway width through this area without impact to the AirTrain structures. Using a curve radius of 847 ft, the alignment ties the revisedtangent section through the piers back to existing in the shortest reasonable distance while maintaining current operating speeds.Upgrading mainline geometry to accommodate a 60mph speed throughout would result in significant impacts to the PANYNJ AirTrain piers and potentially to the loopand slip ramps in this area.
Construct curve with a radius of 847 ft. This proposed design corresponds to the same recommended speed as existing in this area. It is recommended to maintain thecurrent posted speed of 50mph.
MLHCR1
NHS Non-NHS
Urban Interstate
Rolling
847 ft 50 mph
-73.806546 40.715403 -73.825852
acc/mvm acc/mev
9.5% (NB); 10.1% (SB)
01/01/2014 12/31/2016
National Network/Qualifying Highway Access Highway
Urban Principal Arterial Interstate
VWE Horizontal Curve Radius
Justification Number
Rev. 04/24/17
PIN: Route No. and Name:
Project Type:
Functional Class: Design Classification (AASHTO Class):
ADT: % Trucks: Terrain:
Type of Feature:
Statewide Accident Rate:
Cost to fully meet standards:
e.g., social, economic, and environmental
1 Use accidents per million vehicle miles (acc/mvm) for linear highway segments; use accidents per million entering vehicles (acc/meh) for intersections.
Is the Nonstandard Feature a contributing factor? From to
Proposed Value:
Existing Value:
Standard Value:
Exhibit 2-15Nonstandard Feature Justification- VWE Mainline
Latitude and Longitude (Linear Feature) FROM Lat: Long: TO Lat: Long:
Latitude and Longitude (Point Feature) Lat: Long:
2. Accident Analysis
Location:
1. Description of Nonstandard Feature
Design Speed:
Recommended Speed - Existing:
Current Accident Rate1:
Recommended Speed - Proposed:
Anticipated accident rates, severity, and costs:
5. Compatibility with Adjacent Segments and Future Plans
e.g., increased superelevation and speed change lane length for a non-standard ramp radius
6. Other Factors
7. Proposed Treatment (i.e., recommendation)
3. Cost Estimates
4. Mitigation
Cost(s) for incremental improvements:
I-678 – Van Wyck Expressway (Btwn Kew Gardens Interchange and JFK Airport)
Reconstruction
119790 (NB); 122210 (SB)
X735.82
NB PT 27+38.45 to PCC 23+66.38
40.659545
1200 ft 60 mph
838 ft 50 mph
0.41 acc/mvm acc/mev 1.1
Yes No
No change is anticipated. Horizontal curve radius is not a contributing feature to the accident rate. Furthermore, the proposed horizontal curve radius is animprovement from the existing value.
$23 Million $11Million
Construct curve with a radius of 886 ft which meets the minimum radius required for the posted speed of 50mph.Provide curve warning signs and advisory speed signs where warranted. See other sections of this form for detail regarding limitations on achieving the standard orincorporating additional mitigation measures.
Improvement is compatible with future plans.
The proximity of several existing PANYNJ AirTrain piers limits the geometry between Federal Circle and Belt Parkway. The proposed horizontal alignmentaccommodates an increased roadway width through this area without impact to the AirTrain structures. The 886ft radius curve falls within Port Authority jurisdictionand follows the existing roadway layout just north of Federal Circle.Upgrading mainline geometry to accommodate a 60mph speed throughout would result in significant impacts to the PANYNJ AirTrain piers.
Construct curve with a radius of 886 ft. This proposed design corresponds to the same recommended speed as existing in this area. It is recommended to maintain thecurrent posted speed of 50mph.
MLHCR2
NHS Non-NHS
Urban Interstate
Rolling
886 ft 50 mph
-73.806546 40.715403 -73.825852
acc/mvm acc/mev
9.5% (NB); 10.1% (SB)
01/01/2014 12/31/2016
National Network/Qualifying Highway Access Highway
Urban Principal Arterial Interstate
VWE Horizontal Curve Radius
Justification Number
Rev. 04/24/17
PIN: Route No. and Name:
Project Type:
Functional Class: Design Classification (AASHTO Class):
ADT: % Trucks: Terrain:
Type of Feature:
Statewide Accident Rate:
Cost to fully meet standards:
e.g., social, economic, and environmental
1 Use accidents per million vehicle miles (acc/mvm) for linear highway segments; use accidents per million entering vehicles (acc/meh) for intersections.
6. Other Factors
7. Proposed Treatment (i.e., recommendation)
3. Cost Estimates
4. Mitigation
Cost(s) for incremental improvements:
Anticipated accident rates, severity, and costs:
5. Compatibility with Adjacent Segments and Future Plans
e.g., increased superelevation and speed change lane length for a non-standard ramp radius
Is the Nonstandard Feature a contributing factor? From to
Existing Value:
Standard Value:
Exhibit 2-15Nonstandard Feature Justification- VWE Mainline
Latitude and Longitude (Linear Feature) FROM Lat: Long: TO Lat: Long:
Latitude and Longitude (Point Feature) Lat: Long:
Current Accident Rate1:
Recommended Speed - Proposed:
2. Accident Analysis
Location:
1. Description of Nonstandard Feature
Design Speed:
Recommended Speed - Existing:
Proposed Value:
I-678 – Van Wyck Expressway (Btwn Kew Gardens Interchange and JFK Airport)
Reconstruction
119790 (NB); 122210 (SB)
X735.82
NB 229+62.00 to NB 225+82.90
40.659545
570 ft 60 mph
570 ft 60 mph
1.88 acc/mvm acc/mev 1.1
Yes No
Rear-end accidents may be a result of inadequate horizontal stopping sight distance. Also, improvement of the roadway by the addition of a fifth lane is expected toreduce congestion-related crashes like rear-end crashes.
$81 Million N/A
The right shoulder width and subsequently the sight distance vary along the length of this curve. The value of 495 ft reflects the minimum sight line within these limitsand meets the distance required for a 55mph speed. The right shoulder widens beyond standard just north of this curve. Further mitigation is not proposed. See othersections of this form for detail regarding limitations on achieving the standard or incorporating additional mitigation measures.
Improvement is compatible with future plans.
A fifth travel lane is being added to the existing mainline roadway in this area. The current proposed right shoulder width is confined by addition of that lane and theNorthbound VWE existing pavement edges. The existing mainline in this area is newly constructed under a recent Kew Gardens Interchange (KGI) contract. Proposeddesign is intended to provide VWE modifications with minimal disruption/impact to the new construction. Changing this curve to accommodate a 60mph sight linewould impact the existing retaining wall running adjacent to the right shoulder; the retaining wall is not intended to be modified or replaced by this project.
Construct curve with a minimum sight line of 495 feet. Maintain the current posted speed of 50mph.
MLHSSD1
NHS Non-NHS
Urban Interstate
Rolling
495 ft (based on the right travel lane) 55 mph
-73.806546 40.715403 -73.825852
acc/mvm acc/mev
9.5% (NB); 10.1% (SB)
01/01/2014 12/31/2016
National Network/Qualifying Highway Access Highway
Urban Principal Arterial Interstate
VWE Stopping Sight Distance (Horizontal)
Justification Number
Rev. 04/24/17
PIN: Route No. and Name:
Project Type:
Functional Class: Design Classification (AASHTO Class):
ADT: % Trucks: Terrain:
Type of Feature:
Statewide Accident Rate:
Cost to fully meet standards:
e.g., social, economic, and environmental
1 Use accidents per million vehicle miles (acc/mvm) for linear highway segments; use accidents per million entering vehicles (acc/meh) for intersections.
Is the Nonstandard Feature a contributing factor? From to
Proposed Value:
Existing Value:
Standard Value:
Exhibit 2-15Nonstandard Feature Justification- VWE Mainline
Latitude and Longitude (Linear Feature) FROM Lat: Long: TO Lat: Long:
Latitude and Longitude (Point Feature) Lat: Long:
2. Accident Analysis
Location:
1. Description of Nonstandard Feature
Design Speed:
Recommended Speed - Existing:
Current Accident Rate1:
Recommended Speed - Proposed:
Anticipated accident rates, severity, and costs:
5. Compatibility with Adjacent Segments and Future Plans
e.g., increased superelevation and speed change lane length for a non-standard ramp radius
6. Other Factors
7. Proposed Treatment (i.e., recommendation)
3. Cost Estimates
4. Mitigation
Cost(s) for incremental improvements:
I-678 – Van Wyck Expressway (Btwn Kew Gardens Interchange and JFK Airport)
Reconstruction
N/A
X735.82
NB 222+46.47 to NB 213+69.38
40.659545
570 ft 60 mph
515 ft 55 mph
1.09 acc/mvm acc/mev 1.1
Yes No
The current accident rate is approximately the statewide accident rate. 9 crashes were reported in this segment during the three-year period. 44% of these crasheswere rear-end crashes. Improvement of the roadway by the addition of a fifth lane is expected to reduce congestion-related crashes like rear-end crashes. It is thusunlikely that the proposed horizontal stopping sight distance will significantly impact the future accident rate.
$18 Million N/A
The left shoulder width and subsequently the sight distance vary along the length of this curve. The value of 430 ft reflects the minimum sight line within these limitsand meets the distance required for a 50mph speed. The left shoulder width is being optimized within the space available to accommodate improvements. Furthermitigation is not proposed. See other sections of this form for detail regarding limitations on achieving the standard or incorporating additional mitigation measures.
Improvement is compatible with future plans.
A fifth travel lane is being added to the existing mainline roadway in this area. The current proposed left shoulder width is confined by addition of that lane and theNorthbound VWE existing pavement edges. The existing mainline in this area is newly constructed under a recent Kew Gardens Interchange (KGI) contract. Proposeddesign is intended to provide VWE modifications with minimal disruption/impact to the new construction. Changing this curve to accommodate a 60mph sight linewould impact the existing Queens Boulevard Bridge; the bridge structure is not intended to be modified or replaced by this project.
Construct curve with a minimum sight line of 430 feet. Maintain the current posted speed of 50mph.
MLHSSD2
NHS Non-NHS
Urban Interstate
Rolling
430 ft (based on the left travel lane) 50 mph
-73.806546 40.715403 -73.825852
acc/mvm acc/mev
N/A
01/01/2014 12/31/2016
National Network/Qualifying Highway Access Highway
Principal Arterial Interstate
VWE Stopping Sight Distance (Horizontal)
Justification Number
Rev. 04/24/17
PIN: Route No. and Name:
Project Type:
Functional Class: Design Classification (AASHTO Class):
ADT: % Trucks: Terrain:
Type of Feature:
Statewide Accident Rate:
Cost to fully meet standards:
e.g., social, economic, and environmental
1 Use accidents per million vehicle miles (acc/mvm) for linear highway segments; use accidents per million entering vehicles (acc/meh) for intersections.
Anticipated accident rates, severity, and costs:
5. Compatibility with Adjacent Segments and Future Plans
e.g., increased superelevation and speed change lane length for a non-standard ramp radius
6. Other Factors
7. Proposed Treatment (i.e., recommendation)
3. Cost Estimates
4. Mitigation
Cost(s) for incremental improvements:
Is the Nonstandard Feature a contributing factor? From to
Proposed Value:
Existing Value:
Standard Value:
Exhibit 2-15Nonstandard Feature Justification- VWE Mainline
Latitude and Longitude (Linear Feature) FROM Lat: Long: TO Lat: Long:
Latitude and Longitude (Point Feature) Lat: Long:
2. Accident Analysis
Location:
1. Description of Nonstandard Feature
Design Speed:
Recommended Speed - Existing:
Current Accident Rate1:
Recommended Speed - Proposed:
I-678 – Van Wyck Expressway (Btwn Kew Gardens Interchange and JFK Airport)
Reconstruction
119790 (NB); 122210 (SB)
X735.82
NB 27+38.45 to NB 23+66.38
40.659545
570 ft 60 mph
335 ft 40 mph
0.41 acc/mvm acc/mev 1.1
Yes No
The Nonstandard Feature lies within a SDL (Reference Marker 1001-1005), but only one accident was recorded in the area of the Nonstandard Feature. A 40 mphadvisory speed limit will be proposed for this curve. The improvement of the roadway by the addition of a fourth lane is expected to reduce congestion-relatedcrashes.
$13 Million N/A
A 40 mph advisory speed is proposed for this curve. The right shoulder width and the sight distance are being optimized within the space available to accommodateimprovements. See other sections of this form for detail regarding limitations on achieving the standard or incorporating additional mitigation measures.
Improvement is compatible with future plans.
The proximity of several existing PANYNJ AirTrain piers limits the geometry between Federal Circle and Belt Parkway. The proposed horizontal alignmentaccommodates an increased roadway width through this area without impact to the AirTrain structures. Changing this curve to accommodate a 60mph sight line wouldresult in significant impacts to the PANYNJ AirTrain piers.
Construct curve with a minimum sight line of 305 feet. This proposed design corresponds to the same recommended speed as existing in this area.Maintain the current posted speed of 50mph. A 40 mph advisory speed is proposed for this curve.
MLHSSD3
NHS Non-NHS
Urban Interstate
Rolling
305 ft (based on the auxiliary lane) 40 mph
-73.806546 40.715403 -73.825852
acc/mvm acc/mev
9.5% (NB); 10.1% (SB)
01/01/2014 12/31/2016
National Network/Qualifying Highway Access Highway
Urban Principal Arterial Interstate
VWE Stopping Sight Distance (Horizontal)
Justification Number
Rev. 04/24/17
PIN: Route No. and Name:
Project Type:
Functional Class: Design Classification (AASHTO Class):
ADT: % Trucks: Terrain:
Type of Feature:
Statewide Accident Rate:
Cost to fully meet standards:
e.g., social, economic, and environmental
1 Use accidents per million vehicle miles (acc/mvm) for linear highway segments; use accidents per million entering vehicles (acc/meh) for intersections.
Anticipated accident rates, severity, and costs:
5. Compatibility with Adjacent Segments and Future Plans
e.g., increased superelevation and speed change lane length for a non-standard ramp radius
6. Other Factors
7. Proposed Treatment (i.e., recommendation)
3. Cost Estimates
4. Mitigation
Cost(s) for incremental improvements:
Is the Nonstandard Feature a contributing factor? From to
Proposed Value:
Existing Value:
Standard Value:
Exhibit 2-15Nonstandard Feature Justification- VWE Mainline
Latitude and Longitude (Linear Feature) FROM Lat: Long: TO Lat: Long:
Latitude and Longitude (Point Featur