12
CITY OF CROSWELL SANILAC COUNTY, MICHIGAN BID PACKAGE NO.3, WATER TREATMENT PLANT AUGUST 2019 834330 F&V PROJECT NO. DESIGN TEAM: DRAWING INFORMATION: CHECK BY: REVISION: 2125 Ridgewood Dr, Suite 101 P: 989.837.3280 F: 989.837.3290 Midland, MI 48642 DESIGN. BUILD. OPERATE. PROJ MNGR: DESIGNED BY: DRAWN BY: 1 Issued for Bids 08/05/19 DRS AIR INTAKE FILTER AIR INLET SILENCER AIR BACKWASH BLOWER AIR DISCHARGE SILENCER DRAIN 3/4" PRESSURE RELIEF VALVE 3" STL - BACKWASH AIR INLET DRAIN TO SUMP FILTER NO. 3 6" DIP - BACKWASH WASTE 2" AIR PRESSURE & VACUUM RELEASE DRAIN TO SUMP FILTER NO. 2 6" DIP - BACKWASH WASTE 2" AIR PRESSURE & VACUUM RELEASE FILTER NO. 1 6" DIP - BACKWASH WASTE 3" STL. - LOW PRESSURE AIR 8" DIP - RAW WATER 3" STL - LOW PRESSURE AIR 8" BLOWOFF 8" BLOWOFF 8" DIP - RAW WATER 10" DIP - FINISHED WATER TO EXISTING SANITARY SEWER SYSTEM 3" STL - BACKWASH AIR INLET SAMPLE 6" DIP - FILTER INLET 3" STL - BACKWASH AIR INLET CITY OF CROSWELL 8" DIP - RAW WATER 6" DIP - FILTER INLET 6" DIP - FILTER INLET CHLORINE FEED POINT CHLORINE & pH ANALYZER TO EXISTING DISTRIBUTION SYSTEM 6" DIP - FINISHED WATER 6" DIP - FINISHED WATER 6" DIP - FINISHED WATER 10" DIP - FINISHED WATER BACKWASH FLOWMETER 6" DIP - BACKWASH INLET PHOSPHATE FEED POINT BUILDING SUMP EXISTING ELEVATED STORAGE 250,000 GAL. SAMPLE FE 03 8" DIP - BACKWASH WASTE 8" DIP - BACKWASH WASTE 6" DIP - BACKWASH INLET NOTE: PIPING AND EQUIPMENT WITHIN THE DASHED LINE IS SUPPLIED BY THE FILTRATION EQUIPMENT SUPPLIER. FINISHED WATER FLOWMETER CHLORINE FEED POINT 1 3 2 4 23 24 5 30 31 32 32 6 9 8 7 19 10 13 12 11 22 FE 01 18 FE 05 RAW WATER FLOWMETER FE 06 RAW WATER FLOWMETER 8" DIP BYPASS BACKWASH SETTLING BASINS 8" BACKWASH TO SANITARY SEWER 12" BACKWASH WASTE (BY CONTRACTOR) 2" DIP - DRAIN 2" DIP - DRAIN 8" DIP - RAW WATER 8" DIP - RAW WATER WELL PUMP NO.5 SUBMERSIBLE w/PITLESS UNIT (700 GPM) F-01 F-02 F-03 B-01 P-05 STATIC EL. 700.4' 8" DIP - RAW WATER PUMP SETTING EL. 747.6' WELL PUMP NO.6 SUBMERSIBLE w/PITLESS UNIT (1,000 GPM) P-06 GRADE EL. 744.6' 21 20 HWL EL. 892 +/- LWL EL. 864 +/- FLANGE CONNECTION (TYP.) SCOPE OF FILTER MANUFACTURER SUPPLY 10x6 10x6 10x3 10x6 SAMPLE SAMPLE DRAIN TO SUMP 2" AIR PRESSURE & VACUUM RELEASE ELECTRIC ACTUATED BUTTERFLY VALVE (TYP.) ORIFICE PLATE FILTER TO WASTE CHLORINE FEED POINT 834330_P1 081519 davet PROCESS FLOW DIAGRAM P1 GOB MVP DCT SAMPLE 10x6 8x6 8x6 8x6 17 34 14 SAMPLE 2" DIP - DRAIN 16 15 BY CONTRACT 1 CONTRACTOR SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE 2 Addendum 1 08/15/19 DRS M:\Proj833001-835000\834330 Croswell ICE Grant 2018\Cad\Plns\834330_P1.dwg, 8/15/2019 2:42:33 PM, davet, DWG To PDF.pc3

DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

AIR INTAKE

FILTER

AIR INLET

SILENCER

AIR BACKWASH

BLOWER

AIR

DISCHARGE

SILENCER

DRAIN

3/4"

PRESSURE

RELIEF

VALVE

3" S

TL

- B

AC

KW

AS

H A

IR

IN

LE

T

DRAIN TO

SUMP

FILTER NO. 3

6" D

IP

- B

AC

KW

AS

H W

AS

TE

2" AIR PRESSURE &

VACUUM RELEASE

DRAIN TO

SUMP

FILTER NO. 2

6" D

IP

- B

AC

KW

AS

H W

AS

TE

2" AIR PRESSURE &

VACUUM RELEASE

FILTER NO. 1

6" D

IP

- B

AC

KW

AS

H W

AS

TE

3" STL. - LOW PRESSURE AIR

8" DIP - RAW WATER

3" STL - LOW PRESSURE AIR

8" BLOWOFF 8" BLOWOFF

8" D

IP

- R

AW

W

AT

ER

10" DIP - FINISHED WATER

TO EXISTING SANITARY

SEWER SYSTEM

3" S

TL

- B

AC

KW

AS

H A

IR

IN

LE

T

SAMPLE

6" D

IP

- F

IL

TE

R IN

LE

T

3" S

TL

- B

AC

KW

AS

H A

IR

IN

LE

T

CITY OF

CROSWELL

8" DIP - RAW WATER

6" D

IP

- F

IL

TE

R IN

LE

T

6" D

IP

- F

IL

TE

R IN

LE

T

CHLORINE

FEED POINT

CHLORINE & pH

ANALYZER

TO EXISTING

DISTRIBUTION SYSTEM

6" D

IP

- F

IN

IS

HE

D W

AT

ER

6" D

IP

- F

IN

IS

HE

D W

AT

ER

6" D

IP

- F

IN

IS

HE

D W

AT

ER

10" DIP - FINISHED WATER

BACKWASH

FLOWMETER

6" DIP - BACKWASH INLET

PHOSPHATE

FEED POINT

BUILDING

SUMP

EXISTING

ELEVATED STORAGE

250,000 GAL.

SAMPLE

FE

03

8" DIP - BACKWASH WASTE 8" DIP - BACKWASH WASTE

6" DIP - BACKWASH INLET

NOTE:

PIPING AND EQUIPMENT WITHIN THE DASHED LINE IS SUPPLIED BY

THE FILTRATION EQUIPMENT SUPPLIER.

FINISHED WATER

FLOWMETER

CHLORINE

FEED POINT

1

3

2

4

23 24

5

30

31

32 326

9

8

7

19

10

13

12

11

22

FE

01

18

FE

05

RAW WATER

FLOWMETER

FE

06

RAW WATER

FLOWMETER

8" DIP BYPASS

BACKWASH SETTLING BASINS

8" BACKWASH TO SANITARY SEWER

12

" B

AC

KW

AS

H W

AS

TE

(B

Y C

ON

TR

AC

TO

R)

2" DIP - DRAIN 2" DIP - DRAIN

8" D

IP

- R

AW

W

AT

ER

8" D

IP

- R

AW

W

AT

ER

WELL PUMP NO.5

SUBMERSIBLE w/PITLESS UNIT

(700 GPM)

F-01F-02F-03

B-01

P-05

STATIC EL. 700.4'

8" DIP - RAW WATER

PUMP SETTING

EL. 747.6'

WELL PUMP NO.6

SUBMERSIBLE w/PITLESS UNIT

(1,000 GPM)

P-06

GRADE EL. 744.6'

21

20

HWL EL. 892 +/-

LWL EL. 864 +/-

FLANGE CONNECTION (TYP.)

SCOPE OF FILTER MANUFACTURER SUPPLY

10x610x6

10x310x6

SAMPLE SAMPLE

DRAIN TO

SUMP

2" AIR PRESSURE &

VACUUM RELEASE

ELECTRIC ACTUATED

BUTTERFLY VALVE (TYP.)

ORIFICE PLATE

FIL

TE

R T

O W

AS

TE

CHLORINE

FEED POINT

834330_P1

081519 davet

PR

OC

ES

S F

LO

W D

IA

GR

AM

P1

GOB

MVP

DCT

SAMPLE

10x6

8x6 8x68x6

17

3414

SAMPLE

2" DIP - DRAIN

16

15

BY CONTRACT 1

CONTRACTOR

SAMPLE

SAMPLE

SAMPLE

SAMPLE

SAMPLE

SAMPLE

2

Ad

den

du

m 1

08/15/19

DR

S

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

P1

.d

wg

, 8

/1

5/2

01

9 2

:4

2:3

3 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3

AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
AIT
AutoCAD SHX Text
01
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
PI
AutoCAD SHX Text
03
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
PI
AutoCAD SHX Text
02
AutoCAD SHX Text
PI
AutoCAD SHX Text
01
AutoCAD SHX Text
FS
AutoCAD SHX Text
6
AutoCAD SHX Text
FS
AutoCAD SHX Text
5
Page 2: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3

, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

12345678

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

3/8" Ø POLYETHYLENE DISCHARGE

TUBING. 2'-0" MAX. LENGTH

30 GALLON DRUM

(FROM CHEMICAL SUPPLIER)

FOOT VALVE & STRAINER

DRUM SCALE WITH DIGITAL DISPLAY

1/2" POLYETHYLENE

SUCTION TUBING

PHOSPHATE (AND FUTURE KNM04) FEED SCHEMATIC

SCALE: NOT TO SCALE

TO CHEMICAL

INJECTION POINT

CHLORINE GAS FEED SCHEMATIC

SCALE: NOT TO SCALE

CHEMICAL METERING PUMP

(TYP. OF 2)

834330_P2

081519 mikev

CH

EM

IC

AL

F

LO

W D

IA

GR

AM

P2

GOB

MVP

DCT

4-20mA TO

CONTROL PANEL

3/8" CHLORINE GAS

WELL 5

PRE-FILTER

FEED POINT

(100 PPD)

WELL 6

PRE-FILTER

FEED POINT

(100 PPD)

WATER BOOSTER

PUMP

DRAIN

FINISHED

WATER

BALL VALVE

(TYP.)

UNION (TYP.)

2" SCH 80 PVC

CHLORINE

ROOM

PROCESS

ROOM

CHLORINE

ROOM

PROCESS

ROOM

AUTOMATIC SWITCHOVER

MODULE

200 PPD TANK MOUNTED

VACUUM REGULATOR (TYP. OF 2)

RATE SET VALVE AND CONTROLLER

(TYP. OF 2)

VACUUM GAUGE

(TYP. OF 3)

EJECTOR/CHECK ASSEMBLY

(TYP. OF 3)

PRESSURE GAUGE

w/ISOLATION VALVE

(TYP.)

CHECK VALVE (TYP.)

STRAINER

STATIC MIXER

SEAL ALL PENETRATIONS,

BETWEEN CHLORINE

ROOM AND PROCESS

ROOM GAS TIGHT (TYP.)

SEAL ALL PENETRATIONS,

GAS TIGHT (TYP.)

DUAL CHLORINE CYLINDER

SCALE (TYP. OF 2)

1/2" SCH 80 PVC

METERING PUMP SHELF

FOUR FUNCTION VALVE

FLOW MONITOR

1/2" SCH 80 PVC BALL VALVE

WATER BOOSTER

PUMP

PRESSURE REGULATING

VALVE (TYP.)

SOLENOID VALVE (TYP.)

1/2" CHLORINE GAS

1/2" CHLORINE GAS

4-20mA FROM

CONTROL PANEL

4-20mA FROM

CONTROL PANEL

150 LB CYLINDER (BY OWNER)

VENT TO OUTSIDE (TYP.)

4-20mA FROM

CONTROL PANEL

1/2" CHLORINE GAS

3/8" CHLORINE GAS

1 1/2" P

VC

C

LS

1 1/2" P

VC

C

LS

1" P

VC

C

LS

CHLORINE SOLUTION

DIFFUSER

POST-FILTER

FEED POINT

(50 PPD)

1 1/2" P

VC

C

LS

1 1/2" P

VC

C

LS

1" P

VC

C

LS

1 1/2" SCH 80 PVC

1 " SCH 80 PVC

1 1/2" SCH 80 PVC

1/2" CHLORINE GAS

2

Ad

den

du

m 1

08/15/19

DR

S

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

P2

.d

wg

, 8

/1

5/2

01

9 2

:3

9:1

4 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3

AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
Page 3: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3

, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

12345678

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

NORTH

UPPER PROCESS PLAN

SCALE: 1/4"=1'-0"

F-01 F-02 F-03

B-01

AIRWASH BLOWER PACKAGE MOUNTED

ON EQUIPMENT PAD. BLOWER FURNISHED

BY FILTER EQUIPMENT MANUFACTURER

1

SECTION

EQUIPMENT

ROOM

RESTROOM

SAFETY SHOWER / EYEWASH

CHLORINE

ROOM

CHLORINE BOOSTER PUMPS

MOUNTED ON EQUIPMENT PAD

(TYP. OF 2)

TO BACKWASH SETTLING BASINS

FROM

WELL #5

TO DISTRIBUTION SYSTEM

PHOSPHATE FEED EQUIPMENT.

SEE SCHEMATIC FOR DETAILS

1

ELECTRICAL

ROOM

2

FROM

WELL #6

CHLORINE FEED EQUIPMENT. SEE

SCHEMATIC SHEET P2 FOR DETAILS.

5'-5"'

4'-1"'

7'-4"'

1/2" SCH 80 PVC PIPING.

ROUTE ALONG CEILING TO

FEED POINT.

1 1/2" SCH 80 PVC CHLORINE SOLUTION.

ROUTE ALONG CEILING TO FEED POINT.

1 1/2" SCH 80 PVC FINISHED WATER TO CHLORINE

BOOSTER PUMPS. ROUTE ALONG CEILING .

8" FLOW METER

834330_P3

081519 mikev

WW

TP

P

LA

N &

S

EC

TIO

N

P3

GOB

MVP

DCT

2

SECTION

2" AIR RELEASE VALVE

SEE DETAIL SHEET P5.

8" TEE

8" MAGNETIC FLOW METER

1 1/2" PVC CHLORINE

SOLUTION

8" STATIC MIXER

48"x52" CONCRETE SUMP. GROUT

EDGES TO SLOPE TO DRAIN

ALUMINUM GRATING. FIELD CUT

OPENINGS FOR DISCHARGES

INTO THE SUMP

12" TO BACKWASH BASINS.

SEE SITE PLAN FOR

CONTINUATION.

3/4" CORP FOR FUTURE

CHEMICAL FEED CONNECTION

ORIFICE PLATE

8" STATIC MIXER

1/2" BALL VALVE FOR MANUAL

AIR RELEASE. ROUTE

DISCHARGE TO SUMP.

TAP TOP OF 8" RAW FOR

1/2" MANUAL AIR RELEASE

ANGLE CUT PIPE

DISCHARGING INTO

THE SUMP

FILTER FACE PIPING AND VALVES

BY FILTER EQUIPMENT

MANUFACTURER

FILTER FACE PIPING AND VALVES

FURNISHED BY OWNER

CHEMICAL FEED INJECTION QUILL.

SEE DETAIL ON SHEET P5

10" MAGNETIC FLOW METER

INLINE CHLORINE ANALYZER.

ROUTE DISCHARGE TO

EQUIPMENT DRAIN. CONNECT TO

WATER SYSTEM UPSTREAM OF

BFP. SEE SHEET M2.

FILTER CONTROL PANEL

8" TEE AND 45° BEND ROLLED TO

ALIGN RAW PIPING w/FINISHED

WATER PIPING FOR FILTER BYPASS.

ROUTE DISCHARGE OF AIR

RELEASE VALVES TO SUMP (TYP)

GENERAL NOTES:

1. THE CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT FOUNDATION, PAD AND CURB DIMENSIONS.

2. ALL PROCESS PIPING SHALL BE SUPPORTED FROM FLOOR INDEPENDENT OF TANKS AND EQUIPMENT

(SMALL DIAMETER AIR AND CHEMICAL FEED PIPING MAY BE SUPPORTED FROM CEILING). PIPING AT ALL

EQUIPMENT, VALVES, ETC. SHALL BE SUPPORTED SO THAT EQUIPMENT, VALVES, ETC. CAN BE REMOVED

WITHOUT FURTHER SUPPORTING THE PIPING OR REMOVING A SUPPORT. NOT ALL PIPE SUPPORTS ARE

SHOWN. DESIGN OF PIPE SUPPORTS SHALL BE THE CONTRACTOR'S RESPONSIBILITY.

1 2

2324

20

7 11 15

3 4

5

6

9

8

12

13

1013

17

22

18

16

19

21

2

5

4

24

20

21

3/4" SAMPLE FROM UPSTREAM OF

BFP. SEE SHEET M2.

2

Ad

den

du

m 1

08/15/19

DR

S

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

P3

.d

wg

, 8

/1

5/2

01

9 2

:5

0:4

9 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3

AutoCAD SHX Text
P3
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
FILTER ROOM LOOKING NORTH
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
P3
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
FILTER ROOM LOOKING EAST
AutoCAD SHX Text
P3
AutoCAD SHX Text
WELL #5 PIPING SIMILAR
Page 4: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

1/4" TEE

1/4" CLOSE NIPPLE

1/4" BALL VALVE

CARRIER PIPE (D.I.P.)

PRESSURE GAUGE

NO SCALE

PRESSURE GAUGE/SAMPLE TAP DETAIL

90° ELBOW

1/4" CLOSE

NIPPLE

1/4" BALL VALVE

NO SCALE

INTERIOR HOSE BIB

HOSE BIB

CLOSE NIPPLE

PIPE SUPPORT

3/4" WATER SUPPLY PIPE

WA

LL LIN

E

3'-6

"

FLOOR

8"

MA

X

SINK. SEE

SHEET A1

NO SCALE

WELL PUMP AIR/VACUUM VALVE DETAIL

FINISHED FLOOR

TAPPING SADDLE

AIR/VACUUM VALVE

GATE VALVE

STAINLESS STEEL SCREEN

SECURELY ATTACHED TO PIPE END

END WITH 24 MESH 304

GALVANIZED STEEL PIPE

CUT AT 45° ANGLE. COVER

6"

DOUBLE ACTING THROTTLING

DEVICE

STAINLESS STEEL PIPE

EQUIPMENT DRAIN.

SEE DETAIL THIS SHEET

EQUIPMENT DRAIN

NO SCALE

FINISHED FLOOR

PVC REDUCER: 8"xFLOOR DRAIN LEAD.

BUSHINGS AS NECESSARY

FLOOR DRAIN SYSTEM

FLOOR PENETRATION, SEE DETAIL,

THIS SHEET

NO SCALE

FLOOR PENETRATION DETAIL

1"

1" WITHOUT SEAL

CONCRETE

FLOOR

OF SLEEVE

FLUSH WITH TOP

AIR

AREAS)

EXCEPT IN CONTAINMENT

FROM AIR TO AIR

SEAL (NOT REQUIRED

IF PENETRATION IS

MODULAR MECHANICAL

OR WATER

AIR, SOIL

FLOOR SLEEVE

W/ WATER RING

CHEMICAL FEED INJECTION QUILL DETAIL (TYP.)

NO SCALE

T

U

B

E

S

O

L

U

T

I

O

N

"

D

"

D/3 TO D/2

4

5

°

'

BALL CHECK VALVE

SAFETY CHAIN

1" NPT TAP

1" BRASS CORPORATION STOP

SCH. 80 PVC FITTINGS

SECURE PIPE TO

PIPE TO BE

INJECTED

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3

, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

12345678

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

EQUIPMENT PAD TYPE A

SCALE: NOT TO SCALE

#4 BENT BARS DRILLED &

GROUTED INTO CONC. SLAB 2'-0"

O.C. W/3" EMBEDMENT FOR 4"

FLOORS AND 4 1/2" EMBEDMENT

FOR 6" FLOORS

ROUGHEN SURFACE OF CONC. SLAB

CLEAN AND APPLY BONDING AGENT

PRIOR TO POURING NEW CONCRETE

NOTES:

1. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF

3000 PSI

2. REINFORCING STEEL SHALL CONFORM TO ASTM 615, GRADE40

3. BONDING AGENT - TYPE AS RECOMMENDED FOR THIS APPLICATION, AS MFD

BY W.R. GRACE CO., SIKA CHEMICAL CORP. OR ADHESIVE ENG. CO.

4. EQUIPMENT BASE SHALL BE INSTALLED LEVEL

5. PAD SIZE SHALL BE AS INDICATED OR SHOWN ON THE DRAWINGS. WHERE

SIZE IS NOT INDICATED OR SHOWN, PAD SIZE SHALL BE 4" LARGER THAN

EQUIPMENT FRAME EACH SIDE

6. 3/4"x3/4" CHAMFER ALL EDGES (TYP.)

CONC. FLOOR

EQUIPMENT PAD

#4 BARS @ 13" E.W., 1" CLR. FOR

SLABS LESS THAN 4" THICK.

#4 BARS @ 12" E.W., 1 1/2" CLR.

FOR SLABS THICKER THAN 4"

FLOOR

D/2, 8" MIN. 12" MAX.

D+4"

8" MIN.

D/4

C/L PIPE

2 #6 BARS, MIN. 6"

EMBEDMENT

w/EPOXY ANCHORS

CONCRETE PIPE SUPPORT

SCALE: NOT TO SCALE

3 LAYERS OF 30# FELT BETWEEN

PIPE AND CONC. SUPPORT

834330_P5

mikev

PR

OC

ES

S D

ET

AIL

S

P5

GOB

MVP

DCT

VALVE SCHEDULE

1

6

7

8

4

5

2

3

TAG ACTUATOR

CHECK

SIZE TYPE COMMENTS

8"

(3" & LARGER)

10

11

12

13

14

15

9

16

18

19

20

17

22

23

24

30

31

21

32

33

34

LEVER SEE SPECIFICATION 40 05 23

CHECK8" LEVER SEE SPECIFICATION 40 05 23

GATE8" HANDWHEEL SEE SPECIFICATION 40 05 23

GATE8" HANDWHEEL SEE SPECIFICATION 40 05 23

GATE8" HANDWHEEL SEE SPECIFICATION 40 05 23

BUTTERFLY8" HANDWHEEL SEE SPECIFICATION 40 05 23

BUTTERFLY8" HANDWHEEL SEE SPECIFICATION 40 05 23

USE

WELL #5 ISOLATION

WELL #6 ISOLATION

WELL #5 ISOLATION

WELL #6 ISOLATION

FITLER BYPASS

WELL #5 BLOWOFF

WELL #6 BLOWOFF

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 RAW WATER INFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 FILTERED WATER EFFLUENT

BACKWASH HIGH RATE SET

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 BACKWASH INFLUENT

BUTTERFLY8" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 BACKWASH EFFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 RAW WATER INFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 FILTERED WATER EFFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 BACKWASH INFLUENT

BUTTERFLY8" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 BACKWASH EFFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 RAW WATER INFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 FILTERED WATER EFFLUENT

BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 BACKWASH INFLUENT

BUTTERFLY8" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 BACKWASH EFFLUENT

BUTTERFLY6" ELECTRIC

BUTTERFLY3" ELECTRIC BACKWASH HIGH RATE SET

FURNISHED BY FILTER SYSTEM MANUFACTURER

FURNISHED BY FILTER SYSTEM MANUFACTURER

BUTTERFLY10" ELECTRIC FILTER-TO-WASTE FURNISHED BY FILTER SYSTEM MANUFACTURER

BUTTERFLY10" ELECTRIC COMMON FILTER EFFLUENT FURNISHED BY FILTER SYSTEM MANUFACTURER

GATE10" HANDWHEEL SEE SPECIFICATION 40 05 23 ISOLATION

CHECK VALVE3" LEVER SEE SPECIFICATION 40 05 23 AIRWASH BLOWER

BUTTERFLY3" LEVER SEE SPECIFICATION 40 05 23 AIRWASH BLOWER

BUTTERFLY3" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 AIRWASH INFLUENT

BUTTERFLY3" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 AIRWASH INFLUENT

BUTTERFLY3" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 AIRWASH INFLUENT

2

Ad

den

du

m 1

08/15/19

DR

S

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

P5

.d

wg

, 8

/1

5/2

01

9 2

:5

5:2

0 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3

Page 5: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17
Page 6: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17
Page 7: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17
Page 8: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

HMI

PLC INPUT/OUTPUT LIST

SHEET NOTES:

1 ALL EQUIPMENT ON THIS SHEET FURNISHED BY BID PACKAGE 4,

INSTALLED BY ELECTRICAL CONTRACTOR.

RTU-1

WATER STORAGE TANK

CONTROL PANEL (CP-180)

MTU

WATER TREATMENT PLANT

CONTROL PANEL (CP-1)

CPU

I/O

I/O

I/O

I/O

ENET

SWITCH

PLC

HMI

FILTER CONTROL PANEL

(CP-2)

CPU

I/O

I/O

I/O

I/O

PLC

CPU

I/O

I/O

I/O

I/O

PLC

PLC INPUT/OUTPUT LIST

NOTES:

DO - DIGITAL OUTPUT 120 VAC POWERED OR 24VDC

DI - DIGITAL INPUT. 24VDC SOURCE INPUT CARD

AI - ANALOG INPUT. 4-20 MA, 24 VDC CARD

AO - ANALOG OUTPUT. 4-20 MA, 24 VDC CARD

COM - COMMUNICATIONS FAIL

WATER STORAGE TANK (RTU 1)

LEVEL TRANSMITTER (AI)

SECURITY

OCCUPANCY SENSOR (DI)

INTRUSION ARM/DISARM (DI)

LOW TEMPERATURE (DI)

LOW PRESSURE (DI)

HIGH PRESSURE (DI)

INTRUSTION ARMED (DO)

OIT AT WWTP LAB (RTU 2)

PLC (COM)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

UNDEFINED TO DIALER (DO)

TEMPERATURE SWITCH

NORMALLY OPEN

TEMPERATURE SWITCH

NORMALLY CLOSED

CONTROL TRANSFORMER

TERMINAL BLOCK

RELAY CONTACT, NORMALLY CLOSED

RELAY CONTACT, NORMALLY OPEN

NORMALLY CLOSED

OFF-DELAY TIMING CONTACT,

NORMALLY OPEN

OFF-DELAY TIMING CONTACT,

NORMALLY CLOSED

ON-DELAY TIMING CONTACT,

NORMALLY OPEN

ON-DELAY TIMING CONTACT,

FLOW SWITCH, NORMALLY CLOSED

FLOW SWITCH, NORMALLY OPEN

PUSHBUTTON, NORMALLY CLOSED

PUSHBUTTON, NORMALLY OPEN

PUSH-TO-TEST PILOT LIGHT

3-POSITION SELECTOR SWITCH

R

HAND

OFF

AUTO

x

x

ELECTRICAL CONNECTION

FIELD WIRING

BELOW GRADE WIRING

OVERHEAD ELECTRICAL w/ POLES

GROUND ROD (SINGLE LINE DIAGRAM)

POWER TRANSFORMER

REMOVE

5

1

2SINGLE-PHASE MOTOR

THREE-PHASE MOTOR

THERMOSTAT, WALL MOUNTED, 5'-0" A.F.F.

T

FUSE

OCCUPANCY SENSOR..

JUNCTION BOX.

J

3P

30A

(1)

(2)

COMBINATION MOTOR STARTER, NEMA SIZE 1

DISCONNECT SWITCH, NON - FUSED

MOTOR STARTER, NEMA SIZE 2

LPA1

F

DISCONNECT SWITCH, "F" - FUSED

ELECTRICAL LEGEND

a,b

MANUAL MOTOR STARTING SWITCH, 42" A.F.F.

MS

S

A1,3

OCCUPANCY SENSOR W/MANUAL OVERRIDE

OS

DUPLEX RECEPTACLE, 16" AFF.

UNLESS OTHERWISE NOTED. NUMBER

INDICATES CIRCUIT FROM LPA W/2 #12

& 1 #12 GND IN

3

4

" C.

SINGLE-POLE SWITCH, 42" AFF. "ab"

INDICATES ONE SWITCH FOR EACH

CIRCUIT.

CIRCUIT BREAKER IN PANELBOARD, 30

AMP, 3 POLE

O

HOMERUN TO LIGHTINGPANEL LPA,

CIRCUIT 1. HASHMARKS INDICATE QTY.

OF #12 CONDUCTORS PLUS #12 GND. IF

NO HASH MARKS OR WIRES ARE

INDICATED CONDUIT IS SPARE

3

3

SURFACE OR RECESSED MOUNTED

FIXTURE , 3 INDICATES FIXTURE TYPE

FROM SCHEDULE

1

PHOTO NUMBER 1 AND

DIRECTION OF PHOTO

WATER

TREATMENT

PLANT

OC

MTU

SYMBOLS

OC - OCCUPANCY SENSOR

PB - ARM/DISARM PUSHBUTTON

YI - INTRUSION ALARM ARMED INDICATOR

TSL - TEMPERATURE SWITCH LOW

RTU 1

WATER

STORAGE

TANK

WATER TREATMENT PLANT AND TANK ACCESS SYSTEM

DETAIL NOTES:

1.) INTRUSION ALARM IS A HIDDEN ARM/DISARM PUSHBUTTON (HS) ON THE BOTTOM OF THE MTU AND RTU-1 IN TANK BASE ALONG WITH AN PASSIVE

INFARED/ULTRASONIC MOTION DETECTOR (OC) ON THE SIDE OF THE MTU, RTU-1 FACING THE ENTRY DOOR. WHEN THE OPERATOR ENTERS THE

WATER TREATMENT PLANT OR TANK BASE THEY WILL HAVE 30 SECONDS TO PRESS THE HIDDEN ARM/DISARM PUSHBUTTON TO DISABLE THE

INTRUSION ALARM. WHEN THE OPERATOR LEAVES THE WATER TREATMENT PLANT OR TANK BASE THEY WILL PRESS THE HIDDEN ARM/DISARM

PUSHBUTTON TWO TIMES IN SUCCESSION TO ARM THE INTRUSION ALARM AND THEY WILL HAVE 30 SECONDS TO DEPART THE BUILDING OR TANK

BASE. PROVIDE A RED INDICATOR (YI) LIGHT "INTRUSION ALARM ARMED" ON THE FRONT OF THE MTU OR RTU-1 OR TANK BASE TO INDICATE

STATUS.

PB

YI

OC PB

YI

WATER TREATMENT PLANT - MTU

WELL PUMP 1

PUMP ON (DI)

PUMP RUN (DO)

VFD FAULT (DI)

VFD REMOTE SPEED REFERENCE (AO)

VFD IN REMOTE (DI)

PUMP MOTOR AMPS (AI)

FLOW RATE (AI)

FLOW TOTAL (DI)

WELL PUMP 2

PUMP ON (DI)

PUMP RUN (DO)

VFD FAULT (DI)

VFD REMOTE SPEED REFERENCE (AO)

VFD IN REMOTE

PUMP MOTOR AMPS (AI)

FLOW RATE (AI)

FLOW TOTAL (DI)

BOOSTER PUMP 5

PUMP ON (DI)

BOOSTER PUMP 6

PUMP ON (DI)

FINISHED WATER

FLOW RATE (AI)

FLOW TOTAL (DI)

SYSTEM PRESSURE

PRESSURE TRANSMITTER (AI)

AIRWASH BLOWER

BLOWER ON (DI)

BLOWER RUN (DO)

BLOWER FAULT (DI)

HOA IN REMOTE (DI)

BLOWER AMPS (AI)

CHEMICAL FEED

WELL 5 PRE-CHLORINE FLOW PACING (AO)

WELL 6 PRE-CHLORINE FLOW PACING (AO)

FLUORIDE PUMP FLOW PACING (AO)

FLUORIDE PUMP FLOW PACING (AO)

FLUORIDE WEIGHT (AI)

FLUORIDE WEIGHT (AI)

CHLORINE WEIGHT (AI)

CHLORINE WEIGHT (AI)

ELECTRIC POWER SYSTEM

GENERATOR TROUBLE (DI)

GENERATOR RUN CONFIRM (DI)

ATS ON GENERATOR POWER (DI)

ATS ON NORMAL POWER (DI)

SECURITY

OCCUPANCY SENSOR (DI)

INTRUSION ARM/DISARM (DI)

INTRUSION ARMED (DO)

LOW TEMPERATURE (DI)

BUILDING FLOODED (DI)

NL

NL = NIGHT LIGHT

EM = EMERGENCY

TSL TSL

HMIHMI

7

6

5

3

FILTER CONTROL PANEL COMMON ALARM1

RECOGNITION TIMECHANNEL PROGRAMED VOICE MESSAGE

DIALER ALARM CONDITONS

4

2

COMMUNICATIONS FAILURE

GENERATOR FAULT ALARM

WELL OR HIGH SERVICE PUMP FAULT

TANK LOW LEVEL ALARM

8

30 SECONDS

30 SECONDS

30 SECONDS

30 SECONDS

30 SECONDS

WATER TREATMENT PLANT CONTROL PANEL COMMON ALARM

WATER TREATMENT PLANT LOW PRESSURE

PHASE FAILURE ALARM

30 SECONDS

30 SECONDS

180 SECONDS

14

13

12

10

11

9

15

30 SECONDS

TANK HIGH LEVEL ALARM

16

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3

, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

W W W

SCADA NETWORK DIAGRAM

W W W

OWNER SYSTEMS

INTEGRATOR

REMOTE

MAINTENANCE

CABLE

MODEM

PDA/

SMARTPHONE.

EXISTING

OWNER

EQUIPMENT

FIREWALL

SCADA NETWORK DIAGRAM

PDA/

SMARTPHONE.

EXISTING

OWNER

EQUIPMENT

NEW WORK - DARK

FO

PATCH

ENET

SWITCH

FO

PATCH

6 STRAND FO CABLE

BY OWNER

MONITOR

PRINTER

PC

OIT

MAIN COMPUTER

IN LAB

834330_E1

davet

EL

EC

TR

IC

AL

L

EG

EN

D &

S

CA

DA

N

ET

WO

RK

D

IA

GR

AM

E1

GOB

EEH

DCT

2

Ad

den

du

m 1

08/15/19

DR

S

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

E1

.d

wg

, 8

/1

5/2

01

9 1

2:1

3:2

3 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3

Page 9: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

ST

M

ST

M

ST

M

ST

M

ST

M

ST

M

S

T

M

S

T

M

SA

N

SAN

SAN

SAN

SAN

W

W

W

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

WA

TE

R

TR

EA

TM

EN

T

PL

AN

T

WELL #6

WELL #5

100 AMP NEMA 4 STAINLESS

STEEL FUSIBLE DISCONNECT

SWITCH

WELL PUMP DISCONNECT DETAIL

(TYPICAL OF WELL 5 AND 6)

1-5/8"x1-5/8" 12" GAUGE

STEEL STRUT, HOT DIPPED GALV.

ASTM A526-71; B-LINE OR

SUPER-STRUT

3'-0

"3

'-6

"

SURGE ARRESTOR. SQUARE D

SDSA 3650 OR EQUAL.

RIGID GALV. CONDUIT RISERS

CONNECT TO PVC UNDERGROUND

AFTER 90 DEGREE BEND

(TYP).

3000 psi CONCRETE

5-8% AIR ENTRAINMENT

(TYP.)

1'-0"

GRADE

WELL CONNECTION DETAIL

(TYPICAL OF WELL 5 AND 6)

WELLHEAD COVER

GRADE

WELL CASING

RIGID METAL

CONDUIT

PVC SCH 40 CONDUIT

TRANSITION FROM PVC TO RIGID

METAL CONDUIT.

TO WELLHEAD

TO WATER TREATMENT PLANT

SHEET NOTES:

1. SEE SINGLE LINE DIAGRAM SHEET E3 FOR FEEDER AND BRANCH CIRCUIT CONDUCTOR

AND CONDUIT SIZES NOT SHOWN ON THIS SHEET.

2. ALL ELECTRICAL CONDUIT, WIRE, DISCONNECTS, FILTERS SHOWN BETWEEN WELL AND

VFDS PROVIDED BY BIRKMEIER.

3. PARKING LOT LIGHTING AND LIGHTING CONTACTOR AND PHOTO CELL BY OWNER.

NEW GENERATOR

J

6 #12 & 1 #12 GND-1"C FOR

GENERATOR CALL TO RUN, RUNNING &

FAULT SIGNAL

GENERATOR

CONTROL PANEL

NORTH

ELECTRICAL SITE PLAN

SCALE: 1'=20'-0"

GENERATOR FOUNDATION

SECTION

3'-6"

VARIES

ALL SIDES

MAINTAIN 3" CLEAR

AS RECOMMENDED BY MANUFACTURER.

GENERATOR SHALL BE ANCHORED TO FOUNDATION

#5@12" O.C.

TOP & BOTTOM

@ 18" O.C. W/

#4 BENT BARS

IF NOT NOTED.

ADJACENT SIDEWALK OR FINISHED GRADE

BE AS NOTED ON SITE PLAN OR 6" ABOVE

TOP OF GENERATOR FOUNDATION SHALL

CHAMFER EXPOSED

EDGES 3/4"x3/4"

24" LAP

PER GENERATOR MANUFACTURER. BASE BID ON 14'-0".

PE

R G

EN

ER

AT

OR

MA

NU

FA

CT

UR

ER

BA

SE

B

ID

O

N 5'-0"

PLAN

#4 STIRRUPS

@ 18" O.C.

TOP & BOTTOM

#5@12" O.C.

PROVIDE HANDHOLES USING QUANTITIES AND DIMENSIONS SHOWN. BOXES SHALL

BE PRECAST POLYMER/CONCRETE WITH COVERS HAVING A 22,500 LB. DESIGN LOAD.

DESIGN BASED ON QUAZITE BOX AND COVER. ENGINEER APPROVED EQUAL

PERFORMANCE BY ARMOR CAST PRODUCTS OR NORDIC PRODUCTS ACCEPTABLE.

E

1 #4 ALL SIDES

QUAZITE PG1730CA00 COVER

ENGRAVED "ELECTRIC"

3000 psi CONCRETE, 5-8%

AIR ENTRAINMENT

AROUND BOX PERIMETER

QUAZITE PG1730BA12 BOX

INCOMING/OUTGOING CONDUIT

SLOPE TO DRAIN IN BOX.

SAWCUT HOLES AS REQUIRED

1/4" PEA STONE

(INCLUDED IN

HANHOLE)

DO NOT SPLICE

CONDUCTORS.

PULL BOX ONLY!

SEE NOTE.

1'-8

" o

r 2

'-2

"1

2"

6"

12"

MIN.

IN-GROUND HANDHOLE

SCALE: NOT TO SCALE

QUAZITE PG1730EA08 EXTENSION

COORDINATE WITH GENERATOR

ELECTRICAL AND FUEL LINES.

OPENING AS REQUIRED FOR

MANUFACTURER.

PROVIDE ONE EXTRA BAR EACH SIDE

OF OPENING FOR EACH BAR CUT.

2 #12 & 1 #12 GND-3/4"C

TO LIGHTING CONTRACTOR

1

1

2 #12 & 1 #12 GND-3/4"C

TO LIGHTING CONTRACTOR

WELL PUMP DISCONNECT

2 #12 & 1 #12 GND-3/4"C

TO VFD CONTROL CIRCUIT

WELL PUMP DISCONNECT

2 #12 & 1 #12 GND-3/4"C

TO VFD CONTROL CIRCUIT

E

J

3

3

3

3

A9,10,11

ATS

2

2

834330_E2

081519 davet

EL

EC

TR

IC

AL

S

IT

E P

LA

N &

D

ET

AIL

S

E2

EEH

DCT

DRS

SCALE: NOT TO SCALE

FREE STANDING GAS METER SUPPORT DETAIL

18"

MIN.

24"

SEE NOTE 4

24"

MIN

.

60"

MIN

.

72"

MIN

.

2"

SEE NOTE 5

NOTES:

1. USE FREESTANDING SUPPORT WHERE BUILDING WALL WILL NOT SUPPORT

THE METER INSTALLATION.

2. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL RECEIVE PRE-APPROVAL

THAT THIS METER PEDESTAL MEETS THE CONSTRUCTION REQUIREMENTS OF

THE SERVICE PROVIDER.

3. CUSTOMER TO PROVIDE AND INSTALL ITEMS "A" AND "B". FENCE POSTS ARE

NOT ACCEPTABLE.

· FOR 11 M TO 16 M ROTARY METERS - USE TWO 3-INCH ID (INTERNAL

DIAMETER) GALVANIZED STEEL PIPE (SCHEDULE 40) A MINIMUM OF 11 FEET

LONG.

· A 6" (OR LARGER) AUGER IS RECOMMENDED FOR THE POSTHOLES. THE

STEEL PIPES MUST BE PLUMB.

4. THIS METER PEDESTAL CAN ALSO ACCOMODATE THE FOLOWING SIZES:

MULTIPLE 175 RMs, 250 METRIS AND 425, 800, 1000 AND UP TO 11 M COMPACT

ROTARY METERS. 36" BETWEEN POSTS WILL ACCOMODATE MULTIPLES OF UP TO THREE

5. HEIGHT IS FIELD ADJUSTABLE BASED ON SELECTED METER STAND.

ITEM QUANTITY DESCRIPTION MATERIAL No.

A 2 GALVANIZED STEEL PIPE (11 FEET), SEE NOTE 3 CUSTOMER

B - CONCRETE CUSTOMER

C AS REQ'D UNISTRUT CHANNEL - 1 5/8"x3/16" 10097422

D 4 2" STD. UNISTRUT PIPE CLAMP 10090216

CU No. CU102230

A

B

D

A

C

A

B

250 RMM METRIS METERS. UP TO A 60" SPAN IS ACCEPTABLE FOR MULTIPLIES OF GREATER

THAN THREE 250 RMM METRIS METERS.

2

2

2

3

3

3

3

G

G

G

G

G

G

NEW GAS SERVICE PEDESTAL AND 2" GAS

LINE TO GENERATOR BY CONTRACTOR.

SEE DETAIL THIS SHEET.

GAS SERVICE

PROVIDED BY CITY

6 #10 & 1 #10 GND FOR

GENERATOR BATTERY

CHARGER, BLOCK HEATER AND

CONVENIENCE RECEPTACLE

3

3

GFI

NEMA 4 RLC FILTER

2

Ad

den

du

m 1

08/15/19

DR

S

AutoCAD SHX Text
EX.36"STM
AutoCAD SHX Text
UG FIBER MRKER
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
M:\Proj833001-835000\834330 Croswell ICE Grant 2018\Cad\Plns\834330_E2.dwg - plotted on 8/15/2019 2:21 PM - plotted on 8/15/2019 2:21 PM8/15/2019 2:21 PM
Page 10: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

SHEET NOTES:

1 METER BASE PROVIDED BY CROSWELL LIGHT AND POWER, INSTALLED BY

CONTRACTOR.

2 TERMINATE NEUTRAL IN MAIN DISCONNECT (MD).

3 SIZE PER SURGE ARRESTOR MFR. RECOMMENDATIONS. BASE BID ON BREAKER SIZE

SHOWN.

4 NOT USED

5 REFER TO SPECIFICATION SECTION 26 60 00 FOR ADDITIONAL REQUIREMENTS.

6 SIZE TO VFD INPUT, BASE BID ON SIZE SHOWN.

7 SIZE TO MOTOR HP.

8 CONTRACTOR MAY ELECT TO PROVIDE A STAND ALONE SURGE ARRESTOR OR

INSTALL ONE IN THE MDP.

9 - INDICATES FURNISHED WITH EQUIPMENT PACKAGE, INSTALLED BY CONTRACTOR.

10 BREAKER SIZED BY GENERATOR SUPPLIER.

11 LOAD SIDE FILTER PROVIDED BY WELL PUMP SUPPLIER IN ACCORDANCE w/

SPECIFICATION 33 21 10.

12 WORK SHOWN PROVIDED BY BIRKMEIER.

13 GENERATOR AND ATS FURNISHED BY OWNER, INSTALLED BY CONTRACTOR.

SINGLE LINE DIAGRAM

CB5

30A

3P

MDP 480 VOLT - 400AMP BUS - 42 CKT

CB3

20A

3P

G

CB2

20A

3P

480 VOLT 3 PHASE, 4W UNDERGROUND

BY CROSWELL LIGHT AND POWER

G

N

L

E

3 - 4/0 & 1 #4 GND, 2-1/2" C.

4 - 500KCMIL & 1 #1/0 GND 4" C.

CROSWELL LIGHT AND POWER

METER BASE OR CT ENCLOSURE

400A AUTOMATIC

TRANSFER SWITCH

(ATS)

M

10

3 - 500KCMIL & 1 #1/0 GND 3" C.

3 - 500KCMIL & 1 #1/0 GND 3" C.

3

WATER

BOOSTER

PUMP 5

L

L

3

WATER

BOOSTER

PUMP 6

L

10

Q

AIR BACKWASH

BLOWER

CONTROL PANEL

(AWBCP)

AIR WASH

BLOWER

100

WELL PUMP

NO.6

VFD

100

WELL PUMP

NO.5

S

VFD

CB7

200A

3P

LP-A

XFA

480-120/208

THREE

PHASE

15 KVA

BB

PUMP

MOTOR

MLO

150 KW PERMENANT

GENERATOR

CB6

200A

3P

CB1

20A

3P

SECONDARY

SURGE

ARRESTOR

6 6

Q

SC-5 SC-6

CONDUIT AND WIRE SCHEDULE

CONDUCTORCONDUIT CONDUIT

NOTES

REF. QTY.QTY.

SIZE

A

(6) #14 & 1 #14 GND

1 3/4"

B

(1) 18/2 SH/TW/PR

1 3/4"

C MFR. STANDARD CORD 1 AS SHOWN AS REQUIRED

D

(2) 18/2 SH/TW/PR

1 3/4"

E

(2) #14 & (1) #14 GND

1 3/4"

F

(3) #14 & (1) #14 GND

1 3/4"

G

(4) #14 & (1) #14 GND

1 3/4"

H

(6) #14 & (1) #14 GND

1 3/4"

I

(7) #14 & (1) #14 GND

1 3/4"

J

(1) #12 & (1) #12 GND

1 3/4"

K

(2) #12 & (1) #12 GND

1 3/4"

L

(3) #12 & (1) #12 GND

1 3/4"

M

(4) #12 & (1) #12 GND

1 3/4"

N

(3) #4 & (1) #8 GND

1 1-1/2"

O

(3) #18/2 SH/TW/PR

1 1-1/2"

P

(3) #1 & 1 #6 GND

11-1/2"

Q

(3) #10 & (1) #10 GND

1 3/4"

R

(3) #8 & (1) 10 GND

1 1"

S

(3) #1 & (1) #6 GND

1 1-1/2"

T

(4) #10 & (1) #10 GND

1 3/4"

U

(6) #10 & (1) #10 GND

1 1"

V

(2) #8, (2) #10 & (1) #8 GND

1 1"

W

(2) #10 & (1) 10 GND

1 3/4"

X

(8) #14 & 1 #14 GND

1 3/4"

Y

(1) CAT 6 CABLE

1 3/4"

Z

(3) 1/0 & 1 #6 GND

1 3/4"

AA

(12) #14 & 1 # 14 GND

1 3/4"

BB

(4) #6 & (1) #6 GND

1 1-1/4"

CC

(6) #12 & (1) 12 GND

1 3/4"

DD PULL STRING 1 2" SPARE

EE PULL STRING 1 1" SLEEVE FOR WISP

100%

SPEED C

x

START

VFD

x

HAND

OFF

REMOTE

x

x

KEYPAD ON VFD CABINET DOOR

RUN

INPUT

4-20 MA

VFDVFD

FAULT

FROM CP-1

FROM CP-1 TO CP-1TO CP-1

TO CP-1

480V, 3Ø

FROM MDP

VFD CONTROL CIRCUIT DIAGRAM

L1

L3

CURRENT

MONITOR

TO CP-1

REACTOR

3% LINE

(TYPICAL OF WELL PUMPS 5 AND 6)

WELLHEAD

MOTOR

L2

G

N

2

(2) GROUNDING

ELECTRODES

(1) STEEL WATER MAIN

8

400AFS

3-FRSR-400

MAIN DISCONNECT (MD)

PM

**

Q

NEMA 1 ENCLOSURE

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3

, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

CB4

20A

3P

Q

F

RLC

FILTER

11

RLC

FILTER

11

F

100AFS

NEMA 4

100AFS

NEMA 4

(3)

FRS-R175

RLC FILTER

HAND AUTO

120V

480V

M OL

M

OL OL OL

OFF

G RUN PILOT

WATER BOOSTER PUMP

FROM CFCP M

M

TO CP-1

FVNR MOTOR

STARTER

7

480V, 3Ø

FROM MDP

(TYPICAL OF WATER BOOSTER PUMP 5 AND 6)

**

S

CB8

20A

3P

UH-1

EAST

5KW

(3)

FRS-R175

C1

CB9

20A

3P

UH-1

WEST

5KW

CB10

20A

3P

F

30AFS

NEMA 1

UH-1

SOUTH

5KW

12

S S

(3)

FRS-R10

L L L

SPACE

13

13

834330_E3

davet

SIN

GL

E L

IN

E D

IA

GR

AM

E3

GOB

EEH

DCT

x

x

FROM EPCP

PROVIDE NAMEPLATE "DO NOT OPERATE BOTH PUMPS ON GENERATOR POWER"

C1

30AFS

NEMA 1

(3)

FRS-R10

30AFS

NEMA 1

(3)

FRS-R10

CB11

20A

3P

DWH-1

12KW

CB12

20A

3P

F

30AFS

NEMA 1

UH-2

3KW

(3)

FRS-R10

L L

30AFS

NEMA 1

(3)

FRS-R20

HAND AUTO

120V

480V

M OL

M

OL OL OL

FVNR MOTOR

STARTER

BLOWER

OFF

ETMELAPSED TIME METER

G

RUN PILOT

AIR WASH BLOWER WIRING DIAGRAM

FCP-RUN M

M

TO FCP

M

BLOWER SOLENOID

SV-1

x

x

480V, 3Ø

FROM MDP

2

Ad

den

du

m 1

08/15/19

DR

S

SPACE SPACE

F

**

M

TO SV 5 OR 6

M5

TO SV-7

M6

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

E3

.d

wg

, 8

/1

5/2

01

9 7

:5

5:5

2 A

M, d

ave

t, D

WG

T

o P

DF

.p

c3

Page 11: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

S

5

5

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

POWER & INSTRUMENTATION PLAN

SCALE: 1/4"=1'-0"

SHEET NOTES:

1 MOUNT PHASE MONITOR IN NEMA 1 ENCLOSURE ON WALL ABOVE MDP.

2 MOUNT XFA ON WALL ABOVE LP-A.

3 SEE SINGLE LINE DIAGRAM E3 FOR CONDUIT AND CONDUCTOR SIZES.

4 INSTRUMENTATION CONDUIT HOME RUNS MAY BE COMBINED INTO THE FOLLOWING GROUPS:

ANALOG - 4-20mA

DIGITAL - DRY CONTACT 24VDC

CONTROL - 120VAC POWERED

DO NOT INTERMIX GROUPS IN SAME CONDUIT

5 PROVIDE PRE SCH 80 CONDUIT AND OUTLET BOXES IN CHEMICAL ROOM.

6 INDICATES FURNISHED WITH EQUIPMENT PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR.

7 SUSPEND FLOAT FROM JUNCTION BOX ON WALL. REST FLOAT ON FLOOR SO IT TRIPS IF LIQUID LEVEL

EXCEEDS 1" ON FLOOR.

8 CONSTRUCT EQUIPMENT RACK USING 1-5/8" GALVANIZED STEEL (FIBERGLASS IN CHEMICAL ROOM)

CHANNEL AND SUPPORT EQUIPMENT SHOWN FROM FLOOR AND CEILING.

9 FURNISHED BY BID PACKAGE 4. INSTALLED BY ELECTRICAL CONTRACTOR.

10 PARKING LOT LIGHTING, CONDUIT, WIRING, PHOTO CELL AND CONTACTOR BY OWNER.

11 BID PACKAGE 4 MAY ELECT TO FURNISH COMPONENTS SHOWN AS PART OF CP-1 OR AS A STAND

ALONE CONTROL PANEL.

**

SC-5

AIRWASH BLOWER

CONTROL PANEL

PROVIDE 8" SQUARE DUCT

(TYP.)

CP-1 WATER TREATMENT

CONTROL PANEL

(WTCP)

BOOSTER PUMPS 5 & 6

CP-2 FILTER CONTROL

PANEL (FCP)

J

JJ

J

3

3

A22

A5

WTCP

A2

FCP

FCP

FCP

FCP

WTCP

WTCP

A20

A4

MDP

MDP

A3

K

A23

B

E

X

X

X

X

W

K

SC-6

MD

ATSMDP

1

2

E

E

D

8

9

C

B

E

B

3

3

834330_E4

081519 davet

PO

WE

R &

IN

ST

RU

ME

NT

AT

IO

N P

LA

N

E4

GOB

EEH

DCT

PANEL (CFCP) SCHEMATIC

FS-5

120 VAC FROM LPA-13

CHEMICAL FEED CONTROL

PHOSPHATE PUMP 1

FS-6

120V

480V

CPT

C5

C1

EH-1 CONTACTOR

5 KW

EH-1

ER1

ELECTRIC HEATER UH-1 SCHEMATIC

WELL 5 GENERATOR INTERLOCK

R2

ER1

SC-5 ON RELAY

EQUIPMENT PERMISSIVE CONTROL PANEL (EPCP) SCHEMATIC

ATS ON GENERATOR POWER

R1

SC 5 RUN AUX

GENERATOR RELAY

SC 6 RUN AUX

R3

R4

ER1 R4

R3

SC-6 ON RELAY

WELL 6 GENERATOR INTERLOCK

R2

TO

CFCP

R1

TO

CFCP

TO

CFCP

R3

TO VFD

SC-5

R4

TO VFD

SC-6

EPCP R1

WELL PUMP 5 OR 6 RUNNING

R1

R2

R4

R3

R1

R2

EPCP R2R2

R1

ER1

TO UH-1 EAST

CONTACTOR

120 VAC FROM LPA

1

DETAIL NOTES:

DEDICATED RECEPTACLES FOR METERING PUMPS. PROVIDE

LABEL "TOP OUTLET UNSWITCHED".

1

1

HAND AUTO

OFF

x

x

480V, 3Ø

FROM MDP

(TYPICAL FOR EAST AND WEST EH-1, NOT REQUIRED FOR SOUTH EH-1)

ER1

TO UH-1 WEST

CONTACTOR

PHOSPHATE PUMP 2

R3

R4

PCR

(20A)

NL

AUTOHAND

x

OFF

x

LC

PCR

LIGHTING CONTACTOR 6PST (2 SPARE)

MOUNT LIGHTING CONTACTOR IN

SECONDARY CONTROL BUILDING

PARKING LOT LIGHTING WIRING DIAGRAMS

LC

INDIVIDUALLY FUSED

LIGHTING UNITS (TYP)

BRANCH CIRCUIT BREAKER (TYP.)

L N

(20A)

TO LIGHTING

CONTACTOR

BELOW

PHOTO CELL. MOUNT PHOTO CELL

ON SECONDARY CONTROL

BUILDING EXTERIOR

120 VAC

120 VAC

10

J

FCP

X

2

Ad

den

du

m 1

08/15/19

DR

S

N

N

L

L

NORTH

LPA

**

******

** ** **

CFCP

G

E

BOOSTER PUMPS 5 & 6 STARTERS

(BP5S) & (BP6S)

WTCP

A17

**

A24

EPCP

K

BP5S

BP6S

E

BP6S

E

BP5S

E

CP-1

B

FILTER EFFLUENT

RATE CONTROLLER

CP-1

B

B

CP-1

FCP

AA

FCP

3

**

H

WTCP

A29

B

E

**

J

FCP

X

K

CHEMICAL FEED

CONTROL PANEL

(CFCP)

A26

CP-1

D

J

11

11

CP-1

Y

E

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

E4

.d

wg

, 8

/1

5/2

01

9 2

:2

0:1

1 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3

AutoCAD SHX Text
FIT
AutoCAD SHX Text
02
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
FIT
AutoCAD SHX Text
06
AutoCAD SHX Text
FIT
AutoCAD SHX Text
05
AutoCAD SHX Text
FS
AutoCAD SHX Text
6
AutoCAD SHX Text
AIT
AutoCAD SHX Text
01
AutoCAD SHX Text
AIT
AutoCAD SHX Text
03
AutoCAD SHX Text
AE
AutoCAD SHX Text
03
AutoCAD SHX Text
LSH
AutoCAD SHX Text
01
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
CV
AutoCAD SHX Text
FS
AutoCAD SHX Text
5
AutoCAD SHX Text
TSH
AutoCAD SHX Text
PSH
AutoCAD SHX Text
PSL
AutoCAD SHX Text
FIT
AutoCAD SHX Text
01
AutoCAD SHX Text
SV
AutoCAD SHX Text
6
AutoCAD SHX Text
SV
AutoCAD SHX Text
5
AutoCAD SHX Text
SV
AutoCAD SHX Text
7
Page 12: DESIGN. BUILD. OPERATE. · 2020. 6. 4. · orifice plate filter to waste chlorine feed point 834330_p1 081519 davet process flow diagram p1 gob mvp dct sample 10x6 8x6 8x6 8x6 17

2 2 2

2

2

2

22

2

2

2

2 2 22

2

2

2

2

2

2 22 2

1

11

S

S

S

S

S

S S

1

S

SS

S

S

4

4

CIT

Y O

F C

RO

SW

EL

L

SA

NIL

AC

C

OU

NT

Y, M

IC

HIG

AN

BID

P

AC

KA

GE

N

O.3, W

AT

ER

T

RE

AT

ME

NT

P

LA

NT

AUGUST 2019

834330

F&V PROJECT NO.

DESIGN

TEAM:

DRAWING INFORMATION:

CHECK BY:

REVISION:

2125 Ridgewood Dr, Suite 101

P: 989.837.3280

F: 989.837.3290

Midland, MI 48642

DESIGN. BUILD. OPERATE.

PROJ MNGR:

DESIGNED BY:

DRAWN BY:

1Issu

ed

fo

r B

id

s08/05/19

DR

S

LIGHTING & HVAC PLAN

SCALE: 1/4"=1'-0"

LIGHTING/HVAC FIXTURE SCHEDULE

TYPE DESCRIPTION

TOTAL

W

LAMP

MOUNTING

NO W TYPE

1

HOLOPHONE HLW

PC2-P10-40K-AS-T3M-B2SDP-80CRI-PE-EM

50 2 25

120V LED WAL PAK

w/PHOTOCELL AND COLD

WEATHER BATTERY

BACKUP

EXTERIOR - MOUNT AS

SHOWN ON PLANS

2

HOLOPHONE HZL

1N-L48-7000LM-FST-MVOLT-40K-80CRI-E7W-WH

67 1 67

120V LED w/BATTERY

BACKUP FOR FIXTURES

MARKED "EM" ON PLANS

NC INDICATES WIRE AS

NIGHT LIGHT

CEILING MOUNT 4'-0" STRIP

LED

3

LITHONIA

DSXO-LED-20-C-700-40K-T4M-MVOLT-SPA-PER-DDBXD-D

LL12-1.5

POLE LITHONIA SSA 30-DM19AS

91 1 91 120V LED

SITE LIGHTS 30' BRONZE

ALUMINUM POLE

4 SURELITES LPX 5 1 5 RED LED OVER DOORWAY

SHEET NOTES:

1 SEE SINGLE LINE DIAGRAM, SHEET E3 FOR CONDUCTOR AND CONDUIT SIZES.

2 INSTRUMENTATION CONDUIT HOME RUNS MAY BE COMBINED INTO THE FOLLOWING GROUPS:

ANALOG - 4-20mA

DIGITAL - DRY CONTACT 24VDC

CONTROL - 120VAC POWERED

DO NOT INTERMIX GROUPS IN SAME CONDUIT

3 POWER NEW LIGHTING FIXTURES FROM EXISTING CONDUIT. PROVIDE NEW CONDUCTORS.

4 ADJUST LIGHTING FIXTURE LOCATIONS AS NECESSARY TO ACCOMMODATE PROCESS PIPING.

5 PROVIDE NEW GFI, 20 AMP RECEPTACLES AND CONDUCTORS USING EXISTING CONDUIT AND OUTLET

BOXES IN PUMP ROOM.

6 REUSE EXISTING RECEPTACLE PVC OUTLET BOXES, LIGHT SWITCH OUTLET BOXES AND ASSOCIATED

CONDUIT. PROVIDE NEW CONDUCTORS, SWITCHES AND RECEPTACLES AS SHOWN ON PLANS. CLEAN

CONDUITS w/MANDREL AND CLOTH PRIOR TO PULLING NEW CONDUCTORS.

7 PROVIDE PVC SCH. 80 CONDUIT AND OUTLET BOXES IN CHEMICAL ROOM.

8 REUSE EXISTING HVAC CONDUIT AND OUTLET BOXES WHERE CONCEALED. PROVIDE NEW CONDUIT

AND OUTLET BOXES WHERE EXPOSED. PROVIDE NEW SWITCHES AND CONDUCTORS AS SHOWN ON

PLANS.

9 REFER TO SHEET M1 FOR HVAC ELECTRICAL REQUIREMENTS. PROVIDE CONDUITS, CONDUCTORS

AND DISCONNECT SWITCHES FOR GAS UNIT HEATERS, EXHAUST FANS, MOTORIZED DAMPERS AND

THERMOSTATS.

10 CONDUIT AND WIRE MUST BE RUN ABOVE REMOVABLE PANELS.

11 PARKING LOT LIGHTING, CONDUIT, WIRE PHOTOCELL AND CONTACTOR BY OWNER.

LIGHTING PANEL LP-A VOLTAGE 120/208 3Ø, 4W .

LOCATION WATER TREATMENT PLANT MAIN C.B. 50A .

SURFACE ENCLOSURE BUS SIZE 100A .

CIRCUIT LOADS

DESCRIPTION

VOLT AMP. DESCRIPTION LOADS CIRCUIT

NO. AMPS POLE VA LTS. REC. OTH. ØA ØB ØC LTS. REC. OTH. VA POLE AMPS NO

1 15 1 50 1 AIT-02 100 FIT-02 1 50 1 15 2

3 20 1 100 1 WTCP 150 FIT-06 1 50 1 15 4

5 30 1 1000 1 FCP 1000 LAB RECEPTACLES 2 180 1 20 6

7 15 1 180 1 GEN RECEPTACLE 480 20 8

9 20 1 100 1 GEN BATTERY CHARGER 1600 GEN BLOCK HEATER 1 1500 1 20 10

11 20 1 52 7 FILTER ROOM LIGHTS 728 INDIVIDUAL ROOM LIGHTS 7 52 1 20 12

13 20 1 52 10 FILTER ROOM LIGHTS 880 EXTERIOR RECEPTACLES 1 180 1 20 14

15 20 1 91 4 EXTERIOR LIGHTS/LIGHTING CONTROL 1164 FILTER ROOM RECEPTACLES 5 180 1 20 16*

17 20 1 50 1 AIT-01 950 FILTER ROOM RECEPTACLES 5 1 180 1 20 18*

19 20 1 500 1 DEHUMIDIFIER 550 FIT-05 1 50 1 15 20

21 20 1 200 2 EF-1/EF-2 250 AIT-03 1 50 1 15 22

23 20 2 1000 1 UH-3 1100 EPCP 1 100 1 20 24

25 20 1000 1 1100 CFCP 1 100 1 20 26

27 20 6 180 LAB/BATH/MEC REC 380 EF-5 2 200 1 20 28

29 15 1 50 1 FIT-01 50 30

31 20 1 5 2 EXIT LIGHTS 10 32

33 34

35 36

37 38

39 40

41 42

* PROVIDE GFI BREAKER ** LOCKOUT ATTACHMENT TOTALS 3120 3544 3828 * PROVIDE GFI BREAKER **LOCAKOUT ATTACHMENT

A15

A27

A14

A27

A27

A16

A16

A16

A15

A18A14

WP

GFI

A15

A18

A18

A18

A12

A15

A13

WP

GFI

GFI

A27

EF-3

A12

A16

A12

GFI

A26

A26

A12

A28

A28

GFI

WP

EM

NL

EM

NL

3

834330_E5

081519 davet

LIG

HT

IN

G &

H

VA

C P

LA

N

E5

GOB

EEH

DCT

3

NL

L w/MOTORIZED DAMPER

MANUAL MOTOR STARTER

1P

20A

120 VAC FROM "LP-A"

FC

1

NOTES:

SEE M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.

EXHAUST FAN EF-2 WIRING DIAGRAM

1

NL

1P

20A

120 VAC FROM "LP-A"

EXHAUST FAN EF-4 WIRING DIAGRAM

1

EF

1

NOTES:

REFER TO M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.

CHLORINE ALARM

R

FC

R

NL

L w/MOTORIZED DAMPER

EF MANUAL MOTOR STARTER

1P

20A

120 VAC FROM "LP-A"

FC

1

FC

EXHAUST FAN EF-1 WIRING DIAGRAM

L w/MOTORIZED DAMPER

1

NOTES:

SEE M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.

1

EF-2

CONTROLS

L2

EF-4 EF-5

A29/31

WH-1

UH-1

C1

UH-1

1

A21/EF-2

CONTROLS

A21/EF-1

CONTROLS

m

m

mm

A32

MDP

1

EF-1

FUSED DISCONNECT

FUSED DISCONNECT

FUSED DISCONNECT

MDP

1

UH-3

UH-2

FUSED DISCONNECT

A23/25

A21

EF-1

A28

m

MDP

C1L1

EF-1

CONTROLS

1

A19

EF-1

CONTROLS

MDP

A18

EM

NL

A11

NORTH

10 10 10

DOOR SWITCH

EF MANUAL MOTOR STARTER

NL

1P

20A

120 VAC FROM "LP-A"

EXHAUST FAN EF-4 WIRING DIAGRAM

1

EF

1

NOTES:

REFER TO M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.

1

1

L1

MDP

1

2

Ad

den

du

m 1

08/15/19

DR

S

LIGHTING CONTACTOR (LC)

11

A15

K

A31

A31

L w/MOTORIZED DAMPER

EF

M:\P

ro

j8

33

00

1-8

35

00

0\8

34

33

0 C

ro

sw

ell IC

E G

ra

nt 2

01

8\C

ad

\P

ln

s\8

34

33

0_

E5

.d

wg

, 8

/1

5/2

01

9 1

2:2

4:5

0 P

M, d

ave

t, D

WG

T

o P

DF

.p

c3