AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
AIR INTAKE
FILTER
AIR INLET
SILENCER
AIR BACKWASH
BLOWER
AIR
DISCHARGE
SILENCER
DRAIN
3/4"
PRESSURE
RELIEF
VALVE
3" S
TL
- B
AC
KW
AS
H A
IR
IN
LE
T
DRAIN TO
SUMP
FILTER NO. 3
6" D
IP
- B
AC
KW
AS
H W
AS
TE
2" AIR PRESSURE &
VACUUM RELEASE
DRAIN TO
SUMP
FILTER NO. 2
6" D
IP
- B
AC
KW
AS
H W
AS
TE
2" AIR PRESSURE &
VACUUM RELEASE
FILTER NO. 1
6" D
IP
- B
AC
KW
AS
H W
AS
TE
3" STL. - LOW PRESSURE AIR
8" DIP - RAW WATER
3" STL - LOW PRESSURE AIR
8" BLOWOFF 8" BLOWOFF
8" D
IP
- R
AW
W
AT
ER
10" DIP - FINISHED WATER
TO EXISTING SANITARY
SEWER SYSTEM
3" S
TL
- B
AC
KW
AS
H A
IR
IN
LE
T
SAMPLE
6" D
IP
- F
IL
TE
R IN
LE
T
3" S
TL
- B
AC
KW
AS
H A
IR
IN
LE
T
CITY OF
CROSWELL
8" DIP - RAW WATER
6" D
IP
- F
IL
TE
R IN
LE
T
6" D
IP
- F
IL
TE
R IN
LE
T
CHLORINE
FEED POINT
CHLORINE & pH
ANALYZER
TO EXISTING
DISTRIBUTION SYSTEM
6" D
IP
- F
IN
IS
HE
D W
AT
ER
6" D
IP
- F
IN
IS
HE
D W
AT
ER
6" D
IP
- F
IN
IS
HE
D W
AT
ER
10" DIP - FINISHED WATER
BACKWASH
FLOWMETER
6" DIP - BACKWASH INLET
PHOSPHATE
FEED POINT
BUILDING
SUMP
EXISTING
ELEVATED STORAGE
250,000 GAL.
SAMPLE
FE
03
8" DIP - BACKWASH WASTE 8" DIP - BACKWASH WASTE
6" DIP - BACKWASH INLET
NOTE:
PIPING AND EQUIPMENT WITHIN THE DASHED LINE IS SUPPLIED BY
THE FILTRATION EQUIPMENT SUPPLIER.
FINISHED WATER
FLOWMETER
CHLORINE
FEED POINT
1
3
2
4
23 24
5
30
31
32 326
9
8
7
19
10
13
12
11
22
FE
01
18
FE
05
RAW WATER
FLOWMETER
FE
06
RAW WATER
FLOWMETER
8" DIP BYPASS
BACKWASH SETTLING BASINS
8" BACKWASH TO SANITARY SEWER
12
" B
AC
KW
AS
H W
AS
TE
(B
Y C
ON
TR
AC
TO
R)
2" DIP - DRAIN 2" DIP - DRAIN
8" D
IP
- R
AW
W
AT
ER
8" D
IP
- R
AW
W
AT
ER
WELL PUMP NO.5
SUBMERSIBLE w/PITLESS UNIT
(700 GPM)
F-01F-02F-03
B-01
P-05
STATIC EL. 700.4'
8" DIP - RAW WATER
PUMP SETTING
EL. 747.6'
WELL PUMP NO.6
SUBMERSIBLE w/PITLESS UNIT
(1,000 GPM)
P-06
GRADE EL. 744.6'
21
20
HWL EL. 892 +/-
LWL EL. 864 +/-
FLANGE CONNECTION (TYP.)
SCOPE OF FILTER MANUFACTURER SUPPLY
10x610x6
10x310x6
SAMPLE SAMPLE
DRAIN TO
SUMP
2" AIR PRESSURE &
VACUUM RELEASE
ELECTRIC ACTUATED
BUTTERFLY VALVE (TYP.)
ORIFICE PLATE
FIL
TE
R T
O W
AS
TE
CHLORINE
FEED POINT
834330_P1
081519 davet
PR
OC
ES
S F
LO
W D
IA
GR
AM
P1
GOB
MVP
DCT
SAMPLE
10x6
8x6 8x68x6
17
3414
SAMPLE
2" DIP - DRAIN
16
15
BY CONTRACT 1
CONTRACTOR
SAMPLE
SAMPLE
SAMPLE
SAMPLE
SAMPLE
SAMPLE
2
Ad
den
du
m 1
08/15/19
DR
S
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
P1
.d
wg
, 8
/1
5/2
01
9 2
:4
2:3
3 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3
, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
12345678
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
3/8" Ø POLYETHYLENE DISCHARGE
TUBING. 2'-0" MAX. LENGTH
30 GALLON DRUM
(FROM CHEMICAL SUPPLIER)
FOOT VALVE & STRAINER
DRUM SCALE WITH DIGITAL DISPLAY
1/2" POLYETHYLENE
SUCTION TUBING
PHOSPHATE (AND FUTURE KNM04) FEED SCHEMATIC
SCALE: NOT TO SCALE
TO CHEMICAL
INJECTION POINT
CHLORINE GAS FEED SCHEMATIC
SCALE: NOT TO SCALE
CHEMICAL METERING PUMP
(TYP. OF 2)
834330_P2
081519 mikev
CH
EM
IC
AL
F
LO
W D
IA
GR
AM
P2
GOB
MVP
DCT
4-20mA TO
CONTROL PANEL
3/8" CHLORINE GAS
WELL 5
PRE-FILTER
FEED POINT
(100 PPD)
WELL 6
PRE-FILTER
FEED POINT
(100 PPD)
WATER BOOSTER
PUMP
DRAIN
FINISHED
WATER
BALL VALVE
(TYP.)
UNION (TYP.)
2" SCH 80 PVC
CHLORINE
ROOM
PROCESS
ROOM
CHLORINE
ROOM
PROCESS
ROOM
AUTOMATIC SWITCHOVER
MODULE
200 PPD TANK MOUNTED
VACUUM REGULATOR (TYP. OF 2)
RATE SET VALVE AND CONTROLLER
(TYP. OF 2)
VACUUM GAUGE
(TYP. OF 3)
EJECTOR/CHECK ASSEMBLY
(TYP. OF 3)
PRESSURE GAUGE
w/ISOLATION VALVE
(TYP.)
CHECK VALVE (TYP.)
STRAINER
STATIC MIXER
SEAL ALL PENETRATIONS,
BETWEEN CHLORINE
ROOM AND PROCESS
ROOM GAS TIGHT (TYP.)
SEAL ALL PENETRATIONS,
GAS TIGHT (TYP.)
DUAL CHLORINE CYLINDER
SCALE (TYP. OF 2)
1/2" SCH 80 PVC
METERING PUMP SHELF
FOUR FUNCTION VALVE
FLOW MONITOR
1/2" SCH 80 PVC BALL VALVE
WATER BOOSTER
PUMP
PRESSURE REGULATING
VALVE (TYP.)
SOLENOID VALVE (TYP.)
1/2" CHLORINE GAS
1/2" CHLORINE GAS
4-20mA FROM
CONTROL PANEL
4-20mA FROM
CONTROL PANEL
150 LB CYLINDER (BY OWNER)
VENT TO OUTSIDE (TYP.)
4-20mA FROM
CONTROL PANEL
1/2" CHLORINE GAS
3/8" CHLORINE GAS
1 1/2" P
VC
C
LS
1 1/2" P
VC
C
LS
1" P
VC
C
LS
CHLORINE SOLUTION
DIFFUSER
POST-FILTER
FEED POINT
(50 PPD)
1 1/2" P
VC
C
LS
1 1/2" P
VC
C
LS
1" P
VC
C
LS
1 1/2" SCH 80 PVC
1 " SCH 80 PVC
1 1/2" SCH 80 PVC
1/2" CHLORINE GAS
2
Ad
den
du
m 1
08/15/19
DR
S
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
P2
.d
wg
, 8
/1
5/2
01
9 2
:3
9:1
4 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3
, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
12345678
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
NORTH
UPPER PROCESS PLAN
SCALE: 1/4"=1'-0"
F-01 F-02 F-03
B-01
AIRWASH BLOWER PACKAGE MOUNTED
ON EQUIPMENT PAD. BLOWER FURNISHED
BY FILTER EQUIPMENT MANUFACTURER
1
SECTION
EQUIPMENT
ROOM
RESTROOM
SAFETY SHOWER / EYEWASH
CHLORINE
ROOM
CHLORINE BOOSTER PUMPS
MOUNTED ON EQUIPMENT PAD
(TYP. OF 2)
TO BACKWASH SETTLING BASINS
FROM
WELL #5
TO DISTRIBUTION SYSTEM
PHOSPHATE FEED EQUIPMENT.
SEE SCHEMATIC FOR DETAILS
1
ELECTRICAL
ROOM
2
FROM
WELL #6
CHLORINE FEED EQUIPMENT. SEE
SCHEMATIC SHEET P2 FOR DETAILS.
5'-5"'
4'-1"'
7'-4"'
1/2" SCH 80 PVC PIPING.
ROUTE ALONG CEILING TO
FEED POINT.
1 1/2" SCH 80 PVC CHLORINE SOLUTION.
ROUTE ALONG CEILING TO FEED POINT.
1 1/2" SCH 80 PVC FINISHED WATER TO CHLORINE
BOOSTER PUMPS. ROUTE ALONG CEILING .
8" FLOW METER
834330_P3
081519 mikev
WW
TP
P
LA
N &
S
EC
TIO
N
P3
GOB
MVP
DCT
2
SECTION
2" AIR RELEASE VALVE
SEE DETAIL SHEET P5.
8" TEE
8" MAGNETIC FLOW METER
1 1/2" PVC CHLORINE
SOLUTION
8" STATIC MIXER
48"x52" CONCRETE SUMP. GROUT
EDGES TO SLOPE TO DRAIN
ALUMINUM GRATING. FIELD CUT
OPENINGS FOR DISCHARGES
INTO THE SUMP
12" TO BACKWASH BASINS.
SEE SITE PLAN FOR
CONTINUATION.
3/4" CORP FOR FUTURE
CHEMICAL FEED CONNECTION
ORIFICE PLATE
8" STATIC MIXER
1/2" BALL VALVE FOR MANUAL
AIR RELEASE. ROUTE
DISCHARGE TO SUMP.
TAP TOP OF 8" RAW FOR
1/2" MANUAL AIR RELEASE
ANGLE CUT PIPE
DISCHARGING INTO
THE SUMP
FILTER FACE PIPING AND VALVES
BY FILTER EQUIPMENT
MANUFACTURER
FILTER FACE PIPING AND VALVES
FURNISHED BY OWNER
CHEMICAL FEED INJECTION QUILL.
SEE DETAIL ON SHEET P5
10" MAGNETIC FLOW METER
INLINE CHLORINE ANALYZER.
ROUTE DISCHARGE TO
EQUIPMENT DRAIN. CONNECT TO
WATER SYSTEM UPSTREAM OF
BFP. SEE SHEET M2.
FILTER CONTROL PANEL
8" TEE AND 45° BEND ROLLED TO
ALIGN RAW PIPING w/FINISHED
WATER PIPING FOR FILTER BYPASS.
ROUTE DISCHARGE OF AIR
RELEASE VALVES TO SUMP (TYP)
GENERAL NOTES:
1. THE CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT FOUNDATION, PAD AND CURB DIMENSIONS.
2. ALL PROCESS PIPING SHALL BE SUPPORTED FROM FLOOR INDEPENDENT OF TANKS AND EQUIPMENT
(SMALL DIAMETER AIR AND CHEMICAL FEED PIPING MAY BE SUPPORTED FROM CEILING). PIPING AT ALL
EQUIPMENT, VALVES, ETC. SHALL BE SUPPORTED SO THAT EQUIPMENT, VALVES, ETC. CAN BE REMOVED
WITHOUT FURTHER SUPPORTING THE PIPING OR REMOVING A SUPPORT. NOT ALL PIPE SUPPORTS ARE
SHOWN. DESIGN OF PIPE SUPPORTS SHALL BE THE CONTRACTOR'S RESPONSIBILITY.
1 2
2324
20
7 11 15
3 4
5
6
9
8
12
13
1013
17
22
18
16
19
21
2
5
4
24
20
21
3/4" SAMPLE FROM UPSTREAM OF
BFP. SEE SHEET M2.
2
Ad
den
du
m 1
08/15/19
DR
S
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
P3
.d
wg
, 8
/1
5/2
01
9 2
:5
0:4
9 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3
1/4" TEE
1/4" CLOSE NIPPLE
1/4" BALL VALVE
CARRIER PIPE (D.I.P.)
PRESSURE GAUGE
NO SCALE
PRESSURE GAUGE/SAMPLE TAP DETAIL
90° ELBOW
1/4" CLOSE
NIPPLE
1/4" BALL VALVE
NO SCALE
INTERIOR HOSE BIB
HOSE BIB
CLOSE NIPPLE
PIPE SUPPORT
3/4" WATER SUPPLY PIPE
WA
LL LIN
E
3'-6
"
FLOOR
8"
MA
X
SINK. SEE
SHEET A1
NO SCALE
WELL PUMP AIR/VACUUM VALVE DETAIL
FINISHED FLOOR
TAPPING SADDLE
AIR/VACUUM VALVE
GATE VALVE
STAINLESS STEEL SCREEN
SECURELY ATTACHED TO PIPE END
END WITH 24 MESH 304
GALVANIZED STEEL PIPE
CUT AT 45° ANGLE. COVER
6"
DOUBLE ACTING THROTTLING
DEVICE
STAINLESS STEEL PIPE
EQUIPMENT DRAIN.
SEE DETAIL THIS SHEET
EQUIPMENT DRAIN
NO SCALE
FINISHED FLOOR
PVC REDUCER: 8"xFLOOR DRAIN LEAD.
BUSHINGS AS NECESSARY
FLOOR DRAIN SYSTEM
FLOOR PENETRATION, SEE DETAIL,
THIS SHEET
NO SCALE
FLOOR PENETRATION DETAIL
1"
1" WITHOUT SEAL
CONCRETE
FLOOR
OF SLEEVE
FLUSH WITH TOP
AIR
AREAS)
EXCEPT IN CONTAINMENT
FROM AIR TO AIR
SEAL (NOT REQUIRED
IF PENETRATION IS
MODULAR MECHANICAL
OR WATER
AIR, SOIL
FLOOR SLEEVE
W/ WATER RING
CHEMICAL FEED INJECTION QUILL DETAIL (TYP.)
NO SCALE
T
U
B
E
S
O
L
U
T
I
O
N
"
D
"
D/3 TO D/2
4
5
°
'
BALL CHECK VALVE
SAFETY CHAIN
1" NPT TAP
1" BRASS CORPORATION STOP
SCH. 80 PVC FITTINGS
SECURE PIPE TO
PIPE TO BE
INJECTED
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3
, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
12345678
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
EQUIPMENT PAD TYPE A
SCALE: NOT TO SCALE
#4 BENT BARS DRILLED &
GROUTED INTO CONC. SLAB 2'-0"
O.C. W/3" EMBEDMENT FOR 4"
FLOORS AND 4 1/2" EMBEDMENT
FOR 6" FLOORS
ROUGHEN SURFACE OF CONC. SLAB
CLEAN AND APPLY BONDING AGENT
PRIOR TO POURING NEW CONCRETE
NOTES:
1. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF
3000 PSI
2. REINFORCING STEEL SHALL CONFORM TO ASTM 615, GRADE40
3. BONDING AGENT - TYPE AS RECOMMENDED FOR THIS APPLICATION, AS MFD
BY W.R. GRACE CO., SIKA CHEMICAL CORP. OR ADHESIVE ENG. CO.
4. EQUIPMENT BASE SHALL BE INSTALLED LEVEL
5. PAD SIZE SHALL BE AS INDICATED OR SHOWN ON THE DRAWINGS. WHERE
SIZE IS NOT INDICATED OR SHOWN, PAD SIZE SHALL BE 4" LARGER THAN
EQUIPMENT FRAME EACH SIDE
6. 3/4"x3/4" CHAMFER ALL EDGES (TYP.)
CONC. FLOOR
EQUIPMENT PAD
#4 BARS @ 13" E.W., 1" CLR. FOR
SLABS LESS THAN 4" THICK.
#4 BARS @ 12" E.W., 1 1/2" CLR.
FOR SLABS THICKER THAN 4"
FLOOR
D/2, 8" MIN. 12" MAX.
D+4"
8" MIN.
D/4
C/L PIPE
2 #6 BARS, MIN. 6"
EMBEDMENT
w/EPOXY ANCHORS
CONCRETE PIPE SUPPORT
SCALE: NOT TO SCALE
3 LAYERS OF 30# FELT BETWEEN
PIPE AND CONC. SUPPORT
834330_P5
mikev
PR
OC
ES
S D
ET
AIL
S
P5
GOB
MVP
DCT
VALVE SCHEDULE
1
6
7
8
4
5
2
3
TAG ACTUATOR
CHECK
SIZE TYPE COMMENTS
8"
(3" & LARGER)
10
11
12
13
14
15
9
16
18
19
20
17
22
23
24
30
31
21
32
33
34
LEVER SEE SPECIFICATION 40 05 23
CHECK8" LEVER SEE SPECIFICATION 40 05 23
GATE8" HANDWHEEL SEE SPECIFICATION 40 05 23
GATE8" HANDWHEEL SEE SPECIFICATION 40 05 23
GATE8" HANDWHEEL SEE SPECIFICATION 40 05 23
BUTTERFLY8" HANDWHEEL SEE SPECIFICATION 40 05 23
BUTTERFLY8" HANDWHEEL SEE SPECIFICATION 40 05 23
USE
WELL #5 ISOLATION
WELL #6 ISOLATION
WELL #5 ISOLATION
WELL #6 ISOLATION
FITLER BYPASS
WELL #5 BLOWOFF
WELL #6 BLOWOFF
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 RAW WATER INFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 FILTERED WATER EFFLUENT
BACKWASH HIGH RATE SET
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 BACKWASH INFLUENT
BUTTERFLY8" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 BACKWASH EFFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 RAW WATER INFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 FILTERED WATER EFFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 BACKWASH INFLUENT
BUTTERFLY8" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 BACKWASH EFFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 RAW WATER INFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 FILTERED WATER EFFLUENT
BUTTERFLY6" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 BACKWASH INFLUENT
BUTTERFLY8" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 BACKWASH EFFLUENT
BUTTERFLY6" ELECTRIC
BUTTERFLY3" ELECTRIC BACKWASH HIGH RATE SET
FURNISHED BY FILTER SYSTEM MANUFACTURER
FURNISHED BY FILTER SYSTEM MANUFACTURER
BUTTERFLY10" ELECTRIC FILTER-TO-WASTE FURNISHED BY FILTER SYSTEM MANUFACTURER
BUTTERFLY10" ELECTRIC COMMON FILTER EFFLUENT FURNISHED BY FILTER SYSTEM MANUFACTURER
GATE10" HANDWHEEL SEE SPECIFICATION 40 05 23 ISOLATION
CHECK VALVE3" LEVER SEE SPECIFICATION 40 05 23 AIRWASH BLOWER
BUTTERFLY3" LEVER SEE SPECIFICATION 40 05 23 AIRWASH BLOWER
BUTTERFLY3" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-01 AIRWASH INFLUENT
BUTTERFLY3" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-02 AIRWASH INFLUENT
BUTTERFLY3" ELECTRIC FURNISHED BY FILTER SYSTEM MANUFACTURERF-03 AIRWASH INFLUENT
2
Ad
den
du
m 1
08/15/19
DR
S
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
P5
.d
wg
, 8
/1
5/2
01
9 2
:5
5:2
0 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3
HMI
PLC INPUT/OUTPUT LIST
SHEET NOTES:
1 ALL EQUIPMENT ON THIS SHEET FURNISHED BY BID PACKAGE 4,
INSTALLED BY ELECTRICAL CONTRACTOR.
RTU-1
WATER STORAGE TANK
CONTROL PANEL (CP-180)
MTU
WATER TREATMENT PLANT
CONTROL PANEL (CP-1)
CPU
I/O
I/O
I/O
I/O
ENET
SWITCH
PLC
HMI
FILTER CONTROL PANEL
(CP-2)
CPU
I/O
I/O
I/O
I/O
PLC
CPU
I/O
I/O
I/O
I/O
PLC
PLC INPUT/OUTPUT LIST
NOTES:
DO - DIGITAL OUTPUT 120 VAC POWERED OR 24VDC
DI - DIGITAL INPUT. 24VDC SOURCE INPUT CARD
AI - ANALOG INPUT. 4-20 MA, 24 VDC CARD
AO - ANALOG OUTPUT. 4-20 MA, 24 VDC CARD
COM - COMMUNICATIONS FAIL
WATER STORAGE TANK (RTU 1)
LEVEL TRANSMITTER (AI)
SECURITY
OCCUPANCY SENSOR (DI)
INTRUSION ARM/DISARM (DI)
LOW TEMPERATURE (DI)
LOW PRESSURE (DI)
HIGH PRESSURE (DI)
INTRUSTION ARMED (DO)
OIT AT WWTP LAB (RTU 2)
PLC (COM)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
UNDEFINED TO DIALER (DO)
TEMPERATURE SWITCH
NORMALLY OPEN
TEMPERATURE SWITCH
NORMALLY CLOSED
CONTROL TRANSFORMER
TERMINAL BLOCK
RELAY CONTACT, NORMALLY CLOSED
RELAY CONTACT, NORMALLY OPEN
NORMALLY CLOSED
OFF-DELAY TIMING CONTACT,
NORMALLY OPEN
OFF-DELAY TIMING CONTACT,
NORMALLY CLOSED
ON-DELAY TIMING CONTACT,
NORMALLY OPEN
ON-DELAY TIMING CONTACT,
FLOW SWITCH, NORMALLY CLOSED
FLOW SWITCH, NORMALLY OPEN
PUSHBUTTON, NORMALLY CLOSED
PUSHBUTTON, NORMALLY OPEN
PUSH-TO-TEST PILOT LIGHT
3-POSITION SELECTOR SWITCH
R
HAND
OFF
AUTO
x
x
ELECTRICAL CONNECTION
FIELD WIRING
BELOW GRADE WIRING
OVERHEAD ELECTRICAL w/ POLES
GROUND ROD (SINGLE LINE DIAGRAM)
POWER TRANSFORMER
REMOVE
5
1
2SINGLE-PHASE MOTOR
THREE-PHASE MOTOR
THERMOSTAT, WALL MOUNTED, 5'-0" A.F.F.
T
FUSE
OCCUPANCY SENSOR..
JUNCTION BOX.
J
3P
30A
(1)
(2)
COMBINATION MOTOR STARTER, NEMA SIZE 1
DISCONNECT SWITCH, NON - FUSED
MOTOR STARTER, NEMA SIZE 2
LPA1
F
DISCONNECT SWITCH, "F" - FUSED
ELECTRICAL LEGEND
a,b
MANUAL MOTOR STARTING SWITCH, 42" A.F.F.
MS
S
A1,3
OCCUPANCY SENSOR W/MANUAL OVERRIDE
OS
DUPLEX RECEPTACLE, 16" AFF.
UNLESS OTHERWISE NOTED. NUMBER
INDICATES CIRCUIT FROM LPA W/2 #12
& 1 #12 GND IN
3
4
" C.
SINGLE-POLE SWITCH, 42" AFF. "ab"
INDICATES ONE SWITCH FOR EACH
CIRCUIT.
CIRCUIT BREAKER IN PANELBOARD, 30
AMP, 3 POLE
O
HOMERUN TO LIGHTINGPANEL LPA,
CIRCUIT 1. HASHMARKS INDICATE QTY.
OF #12 CONDUCTORS PLUS #12 GND. IF
NO HASH MARKS OR WIRES ARE
INDICATED CONDUIT IS SPARE
3
3
SURFACE OR RECESSED MOUNTED
FIXTURE , 3 INDICATES FIXTURE TYPE
FROM SCHEDULE
1
PHOTO NUMBER 1 AND
DIRECTION OF PHOTO
WATER
TREATMENT
PLANT
OC
MTU
SYMBOLS
OC - OCCUPANCY SENSOR
PB - ARM/DISARM PUSHBUTTON
YI - INTRUSION ALARM ARMED INDICATOR
TSL - TEMPERATURE SWITCH LOW
RTU 1
WATER
STORAGE
TANK
WATER TREATMENT PLANT AND TANK ACCESS SYSTEM
DETAIL NOTES:
1.) INTRUSION ALARM IS A HIDDEN ARM/DISARM PUSHBUTTON (HS) ON THE BOTTOM OF THE MTU AND RTU-1 IN TANK BASE ALONG WITH AN PASSIVE
INFARED/ULTRASONIC MOTION DETECTOR (OC) ON THE SIDE OF THE MTU, RTU-1 FACING THE ENTRY DOOR. WHEN THE OPERATOR ENTERS THE
WATER TREATMENT PLANT OR TANK BASE THEY WILL HAVE 30 SECONDS TO PRESS THE HIDDEN ARM/DISARM PUSHBUTTON TO DISABLE THE
INTRUSION ALARM. WHEN THE OPERATOR LEAVES THE WATER TREATMENT PLANT OR TANK BASE THEY WILL PRESS THE HIDDEN ARM/DISARM
PUSHBUTTON TWO TIMES IN SUCCESSION TO ARM THE INTRUSION ALARM AND THEY WILL HAVE 30 SECONDS TO DEPART THE BUILDING OR TANK
BASE. PROVIDE A RED INDICATOR (YI) LIGHT "INTRUSION ALARM ARMED" ON THE FRONT OF THE MTU OR RTU-1 OR TANK BASE TO INDICATE
STATUS.
PB
YI
OC PB
YI
WATER TREATMENT PLANT - MTU
WELL PUMP 1
PUMP ON (DI)
PUMP RUN (DO)
VFD FAULT (DI)
VFD REMOTE SPEED REFERENCE (AO)
VFD IN REMOTE (DI)
PUMP MOTOR AMPS (AI)
FLOW RATE (AI)
FLOW TOTAL (DI)
WELL PUMP 2
PUMP ON (DI)
PUMP RUN (DO)
VFD FAULT (DI)
VFD REMOTE SPEED REFERENCE (AO)
VFD IN REMOTE
PUMP MOTOR AMPS (AI)
FLOW RATE (AI)
FLOW TOTAL (DI)
BOOSTER PUMP 5
PUMP ON (DI)
BOOSTER PUMP 6
PUMP ON (DI)
FINISHED WATER
FLOW RATE (AI)
FLOW TOTAL (DI)
SYSTEM PRESSURE
PRESSURE TRANSMITTER (AI)
AIRWASH BLOWER
BLOWER ON (DI)
BLOWER RUN (DO)
BLOWER FAULT (DI)
HOA IN REMOTE (DI)
BLOWER AMPS (AI)
CHEMICAL FEED
WELL 5 PRE-CHLORINE FLOW PACING (AO)
WELL 6 PRE-CHLORINE FLOW PACING (AO)
FLUORIDE PUMP FLOW PACING (AO)
FLUORIDE PUMP FLOW PACING (AO)
FLUORIDE WEIGHT (AI)
FLUORIDE WEIGHT (AI)
CHLORINE WEIGHT (AI)
CHLORINE WEIGHT (AI)
ELECTRIC POWER SYSTEM
GENERATOR TROUBLE (DI)
GENERATOR RUN CONFIRM (DI)
ATS ON GENERATOR POWER (DI)
ATS ON NORMAL POWER (DI)
SECURITY
OCCUPANCY SENSOR (DI)
INTRUSION ARM/DISARM (DI)
INTRUSION ARMED (DO)
LOW TEMPERATURE (DI)
BUILDING FLOODED (DI)
NL
NL = NIGHT LIGHT
EM = EMERGENCY
TSL TSL
HMIHMI
7
6
5
3
FILTER CONTROL PANEL COMMON ALARM1
RECOGNITION TIMECHANNEL PROGRAMED VOICE MESSAGE
DIALER ALARM CONDITONS
4
2
COMMUNICATIONS FAILURE
GENERATOR FAULT ALARM
WELL OR HIGH SERVICE PUMP FAULT
TANK LOW LEVEL ALARM
8
30 SECONDS
30 SECONDS
30 SECONDS
30 SECONDS
30 SECONDS
WATER TREATMENT PLANT CONTROL PANEL COMMON ALARM
WATER TREATMENT PLANT LOW PRESSURE
PHASE FAILURE ALARM
30 SECONDS
30 SECONDS
180 SECONDS
14
13
12
10
11
9
15
30 SECONDS
TANK HIGH LEVEL ALARM
16
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3
, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
W W W
SCADA NETWORK DIAGRAM
W W W
OWNER SYSTEMS
INTEGRATOR
REMOTE
MAINTENANCE
CABLE
MODEM
PDA/
SMARTPHONE.
EXISTING
OWNER
EQUIPMENT
FIREWALL
SCADA NETWORK DIAGRAM
PDA/
SMARTPHONE.
EXISTING
OWNER
EQUIPMENT
NEW WORK - DARK
FO
PATCH
ENET
SWITCH
FO
PATCH
6 STRAND FO CABLE
BY OWNER
MONITOR
PRINTER
PC
OIT
MAIN COMPUTER
IN LAB
834330_E1
davet
EL
EC
TR
IC
AL
L
EG
EN
D &
S
CA
DA
N
ET
WO
RK
D
IA
GR
AM
E1
GOB
EEH
DCT
2
Ad
den
du
m 1
08/15/19
DR
S
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
E1
.d
wg
, 8
/1
5/2
01
9 1
2:1
3:2
3 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
ST
M
ST
M
ST
M
ST
M
ST
M
ST
M
S
T
M
S
T
M
SA
N
SAN
SAN
SAN
SAN
W
W
W
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
WA
TE
R
TR
EA
TM
EN
T
PL
AN
T
WELL #6
WELL #5
100 AMP NEMA 4 STAINLESS
STEEL FUSIBLE DISCONNECT
SWITCH
WELL PUMP DISCONNECT DETAIL
(TYPICAL OF WELL 5 AND 6)
1-5/8"x1-5/8" 12" GAUGE
STEEL STRUT, HOT DIPPED GALV.
ASTM A526-71; B-LINE OR
SUPER-STRUT
3'-0
"3
'-6
"
SURGE ARRESTOR. SQUARE D
SDSA 3650 OR EQUAL.
RIGID GALV. CONDUIT RISERS
CONNECT TO PVC UNDERGROUND
AFTER 90 DEGREE BEND
(TYP).
3000 psi CONCRETE
5-8% AIR ENTRAINMENT
(TYP.)
1'-0"
GRADE
WELL CONNECTION DETAIL
(TYPICAL OF WELL 5 AND 6)
WELLHEAD COVER
GRADE
WELL CASING
RIGID METAL
CONDUIT
PVC SCH 40 CONDUIT
TRANSITION FROM PVC TO RIGID
METAL CONDUIT.
TO WELLHEAD
TO WATER TREATMENT PLANT
SHEET NOTES:
1. SEE SINGLE LINE DIAGRAM SHEET E3 FOR FEEDER AND BRANCH CIRCUIT CONDUCTOR
AND CONDUIT SIZES NOT SHOWN ON THIS SHEET.
2. ALL ELECTRICAL CONDUIT, WIRE, DISCONNECTS, FILTERS SHOWN BETWEEN WELL AND
VFDS PROVIDED BY BIRKMEIER.
3. PARKING LOT LIGHTING AND LIGHTING CONTACTOR AND PHOTO CELL BY OWNER.
NEW GENERATOR
J
6 #12 & 1 #12 GND-1"C FOR
GENERATOR CALL TO RUN, RUNNING &
FAULT SIGNAL
GENERATOR
CONTROL PANEL
NORTH
ELECTRICAL SITE PLAN
SCALE: 1'=20'-0"
GENERATOR FOUNDATION
SECTION
3'-6"
VARIES
ALL SIDES
MAINTAIN 3" CLEAR
AS RECOMMENDED BY MANUFACTURER.
GENERATOR SHALL BE ANCHORED TO FOUNDATION
#5@12" O.C.
TOP & BOTTOM
@ 18" O.C. W/
#4 BENT BARS
IF NOT NOTED.
ADJACENT SIDEWALK OR FINISHED GRADE
BE AS NOTED ON SITE PLAN OR 6" ABOVE
TOP OF GENERATOR FOUNDATION SHALL
CHAMFER EXPOSED
EDGES 3/4"x3/4"
24" LAP
PER GENERATOR MANUFACTURER. BASE BID ON 14'-0".
PE
R G
EN
ER
AT
OR
MA
NU
FA
CT
UR
ER
BA
SE
B
ID
O
N 5'-0"
PLAN
#4 STIRRUPS
@ 18" O.C.
TOP & BOTTOM
#5@12" O.C.
PROVIDE HANDHOLES USING QUANTITIES AND DIMENSIONS SHOWN. BOXES SHALL
BE PRECAST POLYMER/CONCRETE WITH COVERS HAVING A 22,500 LB. DESIGN LOAD.
DESIGN BASED ON QUAZITE BOX AND COVER. ENGINEER APPROVED EQUAL
PERFORMANCE BY ARMOR CAST PRODUCTS OR NORDIC PRODUCTS ACCEPTABLE.
E
1 #4 ALL SIDES
QUAZITE PG1730CA00 COVER
ENGRAVED "ELECTRIC"
3000 psi CONCRETE, 5-8%
AIR ENTRAINMENT
AROUND BOX PERIMETER
QUAZITE PG1730BA12 BOX
INCOMING/OUTGOING CONDUIT
SLOPE TO DRAIN IN BOX.
SAWCUT HOLES AS REQUIRED
1/4" PEA STONE
(INCLUDED IN
HANHOLE)
DO NOT SPLICE
CONDUCTORS.
PULL BOX ONLY!
SEE NOTE.
1'-8
" o
r 2
'-2
"1
2"
6"
12"
MIN.
IN-GROUND HANDHOLE
SCALE: NOT TO SCALE
QUAZITE PG1730EA08 EXTENSION
COORDINATE WITH GENERATOR
ELECTRICAL AND FUEL LINES.
OPENING AS REQUIRED FOR
MANUFACTURER.
PROVIDE ONE EXTRA BAR EACH SIDE
OF OPENING FOR EACH BAR CUT.
2 #12 & 1 #12 GND-3/4"C
TO LIGHTING CONTRACTOR
1
1
2 #12 & 1 #12 GND-3/4"C
TO LIGHTING CONTRACTOR
WELL PUMP DISCONNECT
2 #12 & 1 #12 GND-3/4"C
TO VFD CONTROL CIRCUIT
WELL PUMP DISCONNECT
2 #12 & 1 #12 GND-3/4"C
TO VFD CONTROL CIRCUIT
E
J
3
3
3
3
A9,10,11
ATS
2
2
834330_E2
081519 davet
EL
EC
TR
IC
AL
S
IT
E P
LA
N &
D
ET
AIL
S
E2
EEH
DCT
DRS
SCALE: NOT TO SCALE
FREE STANDING GAS METER SUPPORT DETAIL
18"
MIN.
24"
SEE NOTE 4
24"
MIN
.
60"
MIN
.
72"
MIN
.
2"
SEE NOTE 5
NOTES:
1. USE FREESTANDING SUPPORT WHERE BUILDING WALL WILL NOT SUPPORT
THE METER INSTALLATION.
2. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL RECEIVE PRE-APPROVAL
THAT THIS METER PEDESTAL MEETS THE CONSTRUCTION REQUIREMENTS OF
THE SERVICE PROVIDER.
3. CUSTOMER TO PROVIDE AND INSTALL ITEMS "A" AND "B". FENCE POSTS ARE
NOT ACCEPTABLE.
· FOR 11 M TO 16 M ROTARY METERS - USE TWO 3-INCH ID (INTERNAL
DIAMETER) GALVANIZED STEEL PIPE (SCHEDULE 40) A MINIMUM OF 11 FEET
LONG.
· A 6" (OR LARGER) AUGER IS RECOMMENDED FOR THE POSTHOLES. THE
STEEL PIPES MUST BE PLUMB.
4. THIS METER PEDESTAL CAN ALSO ACCOMODATE THE FOLOWING SIZES:
MULTIPLE 175 RMs, 250 METRIS AND 425, 800, 1000 AND UP TO 11 M COMPACT
ROTARY METERS. 36" BETWEEN POSTS WILL ACCOMODATE MULTIPLES OF UP TO THREE
5. HEIGHT IS FIELD ADJUSTABLE BASED ON SELECTED METER STAND.
ITEM QUANTITY DESCRIPTION MATERIAL No.
A 2 GALVANIZED STEEL PIPE (11 FEET), SEE NOTE 3 CUSTOMER
B - CONCRETE CUSTOMER
C AS REQ'D UNISTRUT CHANNEL - 1 5/8"x3/16" 10097422
D 4 2" STD. UNISTRUT PIPE CLAMP 10090216
CU No. CU102230
A
B
D
A
C
A
B
250 RMM METRIS METERS. UP TO A 60" SPAN IS ACCEPTABLE FOR MULTIPLIES OF GREATER
THAN THREE 250 RMM METRIS METERS.
2
2
2
3
3
3
3
G
G
G
G
G
G
NEW GAS SERVICE PEDESTAL AND 2" GAS
LINE TO GENERATOR BY CONTRACTOR.
SEE DETAIL THIS SHEET.
GAS SERVICE
PROVIDED BY CITY
6 #10 & 1 #10 GND FOR
GENERATOR BATTERY
CHARGER, BLOCK HEATER AND
CONVENIENCE RECEPTACLE
3
3
GFI
NEMA 4 RLC FILTER
2
Ad
den
du
m 1
08/15/19
DR
S
SHEET NOTES:
1 METER BASE PROVIDED BY CROSWELL LIGHT AND POWER, INSTALLED BY
CONTRACTOR.
2 TERMINATE NEUTRAL IN MAIN DISCONNECT (MD).
3 SIZE PER SURGE ARRESTOR MFR. RECOMMENDATIONS. BASE BID ON BREAKER SIZE
SHOWN.
4 NOT USED
5 REFER TO SPECIFICATION SECTION 26 60 00 FOR ADDITIONAL REQUIREMENTS.
6 SIZE TO VFD INPUT, BASE BID ON SIZE SHOWN.
7 SIZE TO MOTOR HP.
8 CONTRACTOR MAY ELECT TO PROVIDE A STAND ALONE SURGE ARRESTOR OR
INSTALL ONE IN THE MDP.
9 - INDICATES FURNISHED WITH EQUIPMENT PACKAGE, INSTALLED BY CONTRACTOR.
10 BREAKER SIZED BY GENERATOR SUPPLIER.
11 LOAD SIDE FILTER PROVIDED BY WELL PUMP SUPPLIER IN ACCORDANCE w/
SPECIFICATION 33 21 10.
12 WORK SHOWN PROVIDED BY BIRKMEIER.
13 GENERATOR AND ATS FURNISHED BY OWNER, INSTALLED BY CONTRACTOR.
SINGLE LINE DIAGRAM
CB5
30A
3P
MDP 480 VOLT - 400AMP BUS - 42 CKT
CB3
20A
3P
G
CB2
20A
3P
480 VOLT 3 PHASE, 4W UNDERGROUND
BY CROSWELL LIGHT AND POWER
G
N
L
E
3 - 4/0 & 1 #4 GND, 2-1/2" C.
4 - 500KCMIL & 1 #1/0 GND 4" C.
CROSWELL LIGHT AND POWER
METER BASE OR CT ENCLOSURE
400A AUTOMATIC
TRANSFER SWITCH
(ATS)
M
10
3 - 500KCMIL & 1 #1/0 GND 3" C.
3 - 500KCMIL & 1 #1/0 GND 3" C.
3
WATER
BOOSTER
PUMP 5
L
L
3
WATER
BOOSTER
PUMP 6
L
10
Q
AIR BACKWASH
BLOWER
CONTROL PANEL
(AWBCP)
AIR WASH
BLOWER
100
WELL PUMP
NO.6
VFD
100
WELL PUMP
NO.5
S
VFD
CB7
200A
3P
LP-A
XFA
480-120/208
THREE
PHASE
15 KVA
BB
PUMP
MOTOR
MLO
150 KW PERMENANT
GENERATOR
CB6
200A
3P
CB1
20A
3P
SECONDARY
SURGE
ARRESTOR
6 6
Q
SC-5 SC-6
CONDUIT AND WIRE SCHEDULE
CONDUCTORCONDUIT CONDUIT
NOTES
REF. QTY.QTY.
SIZE
A
(6) #14 & 1 #14 GND
1 3/4"
B
(1) 18/2 SH/TW/PR
1 3/4"
C MFR. STANDARD CORD 1 AS SHOWN AS REQUIRED
D
(2) 18/2 SH/TW/PR
1 3/4"
E
(2) #14 & (1) #14 GND
1 3/4"
F
(3) #14 & (1) #14 GND
1 3/4"
G
(4) #14 & (1) #14 GND
1 3/4"
H
(6) #14 & (1) #14 GND
1 3/4"
I
(7) #14 & (1) #14 GND
1 3/4"
J
(1) #12 & (1) #12 GND
1 3/4"
K
(2) #12 & (1) #12 GND
1 3/4"
L
(3) #12 & (1) #12 GND
1 3/4"
M
(4) #12 & (1) #12 GND
1 3/4"
N
(3) #4 & (1) #8 GND
1 1-1/2"
O
(3) #18/2 SH/TW/PR
1 1-1/2"
P
(3) #1 & 1 #6 GND
11-1/2"
Q
(3) #10 & (1) #10 GND
1 3/4"
R
(3) #8 & (1) 10 GND
1 1"
S
(3) #1 & (1) #6 GND
1 1-1/2"
T
(4) #10 & (1) #10 GND
1 3/4"
U
(6) #10 & (1) #10 GND
1 1"
V
(2) #8, (2) #10 & (1) #8 GND
1 1"
W
(2) #10 & (1) 10 GND
1 3/4"
X
(8) #14 & 1 #14 GND
1 3/4"
Y
(1) CAT 6 CABLE
1 3/4"
Z
(3) 1/0 & 1 #6 GND
1 3/4"
AA
(12) #14 & 1 # 14 GND
1 3/4"
BB
(4) #6 & (1) #6 GND
1 1-1/4"
CC
(6) #12 & (1) 12 GND
1 3/4"
DD PULL STRING 1 2" SPARE
EE PULL STRING 1 1" SLEEVE FOR WISP
100%
SPEED C
x
START
VFD
x
HAND
OFF
REMOTE
x
x
KEYPAD ON VFD CABINET DOOR
RUN
INPUT
4-20 MA
VFDVFD
FAULT
FROM CP-1
FROM CP-1 TO CP-1TO CP-1
TO CP-1
480V, 3Ø
FROM MDP
VFD CONTROL CIRCUIT DIAGRAM
L1
L3
CURRENT
MONITOR
TO CP-1
REACTOR
3% LINE
(TYPICAL OF WELL PUMPS 5 AND 6)
WELLHEAD
MOTOR
L2
G
N
2
(2) GROUNDING
ELECTRODES
(1) STEEL WATER MAIN
8
400AFS
3-FRSR-400
MAIN DISCONNECT (MD)
PM
**
Q
NEMA 1 ENCLOSURE
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3
, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
CB4
20A
3P
Q
F
RLC
FILTER
11
RLC
FILTER
11
F
100AFS
NEMA 4
100AFS
NEMA 4
(3)
FRS-R175
RLC FILTER
HAND AUTO
120V
480V
M OL
M
OL OL OL
OFF
G RUN PILOT
WATER BOOSTER PUMP
FROM CFCP M
M
TO CP-1
FVNR MOTOR
STARTER
7
480V, 3Ø
FROM MDP
(TYPICAL OF WATER BOOSTER PUMP 5 AND 6)
**
S
CB8
20A
3P
UH-1
EAST
5KW
(3)
FRS-R175
C1
CB9
20A
3P
UH-1
WEST
5KW
CB10
20A
3P
F
30AFS
NEMA 1
UH-1
SOUTH
5KW
12
S S
(3)
FRS-R10
L L L
SPACE
13
13
834330_E3
davet
SIN
GL
E L
IN
E D
IA
GR
AM
E3
GOB
EEH
DCT
x
x
FROM EPCP
PROVIDE NAMEPLATE "DO NOT OPERATE BOTH PUMPS ON GENERATOR POWER"
C1
30AFS
NEMA 1
(3)
FRS-R10
30AFS
NEMA 1
(3)
FRS-R10
CB11
20A
3P
DWH-1
12KW
CB12
20A
3P
F
30AFS
NEMA 1
UH-2
3KW
(3)
FRS-R10
L L
30AFS
NEMA 1
(3)
FRS-R20
HAND AUTO
120V
480V
M OL
M
OL OL OL
FVNR MOTOR
STARTER
BLOWER
OFF
ETMELAPSED TIME METER
G
RUN PILOT
AIR WASH BLOWER WIRING DIAGRAM
FCP-RUN M
M
TO FCP
M
BLOWER SOLENOID
SV-1
x
x
480V, 3Ø
FROM MDP
2
Ad
den
du
m 1
08/15/19
DR
S
SPACE SPACE
F
**
M
TO SV 5 OR 6
M5
TO SV-7
M6
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
E3
.d
wg
, 8
/1
5/2
01
9 7
:5
5:5
2 A
M, d
ave
t, D
WG
T
o P
DF
.p
c3
S
5
5
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
POWER & INSTRUMENTATION PLAN
SCALE: 1/4"=1'-0"
SHEET NOTES:
1 MOUNT PHASE MONITOR IN NEMA 1 ENCLOSURE ON WALL ABOVE MDP.
2 MOUNT XFA ON WALL ABOVE LP-A.
3 SEE SINGLE LINE DIAGRAM E3 FOR CONDUIT AND CONDUCTOR SIZES.
4 INSTRUMENTATION CONDUIT HOME RUNS MAY BE COMBINED INTO THE FOLLOWING GROUPS:
ANALOG - 4-20mA
DIGITAL - DRY CONTACT 24VDC
CONTROL - 120VAC POWERED
DO NOT INTERMIX GROUPS IN SAME CONDUIT
5 PROVIDE PRE SCH 80 CONDUIT AND OUTLET BOXES IN CHEMICAL ROOM.
6 INDICATES FURNISHED WITH EQUIPMENT PACKAGE, INSTALLED BY ELECTRICAL CONTRACTOR.
7 SUSPEND FLOAT FROM JUNCTION BOX ON WALL. REST FLOAT ON FLOOR SO IT TRIPS IF LIQUID LEVEL
EXCEEDS 1" ON FLOOR.
8 CONSTRUCT EQUIPMENT RACK USING 1-5/8" GALVANIZED STEEL (FIBERGLASS IN CHEMICAL ROOM)
CHANNEL AND SUPPORT EQUIPMENT SHOWN FROM FLOOR AND CEILING.
9 FURNISHED BY BID PACKAGE 4. INSTALLED BY ELECTRICAL CONTRACTOR.
10 PARKING LOT LIGHTING, CONDUIT, WIRING, PHOTO CELL AND CONTACTOR BY OWNER.
11 BID PACKAGE 4 MAY ELECT TO FURNISH COMPONENTS SHOWN AS PART OF CP-1 OR AS A STAND
ALONE CONTROL PANEL.
**
SC-5
AIRWASH BLOWER
CONTROL PANEL
PROVIDE 8" SQUARE DUCT
(TYP.)
CP-1 WATER TREATMENT
CONTROL PANEL
(WTCP)
BOOSTER PUMPS 5 & 6
CP-2 FILTER CONTROL
PANEL (FCP)
J
JJ
J
3
3
A22
A5
WTCP
A2
FCP
FCP
FCP
FCP
WTCP
WTCP
A20
A4
MDP
MDP
A3
K
A23
B
E
X
X
X
X
W
K
SC-6
MD
ATSMDP
1
2
E
E
D
8
9
C
B
E
B
3
3
834330_E4
081519 davet
PO
WE
R &
IN
ST
RU
ME
NT
AT
IO
N P
LA
N
E4
GOB
EEH
DCT
PANEL (CFCP) SCHEMATIC
FS-5
120 VAC FROM LPA-13
CHEMICAL FEED CONTROL
PHOSPHATE PUMP 1
FS-6
120V
480V
CPT
C5
C1
EH-1 CONTACTOR
5 KW
EH-1
ER1
ELECTRIC HEATER UH-1 SCHEMATIC
WELL 5 GENERATOR INTERLOCK
R2
ER1
SC-5 ON RELAY
EQUIPMENT PERMISSIVE CONTROL PANEL (EPCP) SCHEMATIC
ATS ON GENERATOR POWER
R1
SC 5 RUN AUX
GENERATOR RELAY
SC 6 RUN AUX
R3
R4
ER1 R4
R3
SC-6 ON RELAY
WELL 6 GENERATOR INTERLOCK
R2
TO
CFCP
R1
TO
CFCP
TO
CFCP
R3
TO VFD
SC-5
R4
TO VFD
SC-6
EPCP R1
WELL PUMP 5 OR 6 RUNNING
R1
R2
R4
R3
R1
R2
EPCP R2R2
R1
ER1
TO UH-1 EAST
CONTACTOR
120 VAC FROM LPA
1
DETAIL NOTES:
DEDICATED RECEPTACLES FOR METERING PUMPS. PROVIDE
LABEL "TOP OUTLET UNSWITCHED".
1
1
HAND AUTO
OFF
x
x
480V, 3Ø
FROM MDP
(TYPICAL FOR EAST AND WEST EH-1, NOT REQUIRED FOR SOUTH EH-1)
ER1
TO UH-1 WEST
CONTACTOR
PHOSPHATE PUMP 2
R3
R4
PCR
(20A)
NL
AUTOHAND
x
OFF
x
LC
PCR
LIGHTING CONTACTOR 6PST (2 SPARE)
MOUNT LIGHTING CONTACTOR IN
SECONDARY CONTROL BUILDING
PARKING LOT LIGHTING WIRING DIAGRAMS
LC
INDIVIDUALLY FUSED
LIGHTING UNITS (TYP)
BRANCH CIRCUIT BREAKER (TYP.)
L N
(20A)
TO LIGHTING
CONTACTOR
BELOW
PHOTO CELL. MOUNT PHOTO CELL
ON SECONDARY CONTROL
BUILDING EXTERIOR
120 VAC
120 VAC
10
J
FCP
X
2
Ad
den
du
m 1
08/15/19
DR
S
N
N
L
L
NORTH
LPA
**
******
** ** **
CFCP
G
E
BOOSTER PUMPS 5 & 6 STARTERS
(BP5S) & (BP6S)
WTCP
A17
**
A24
EPCP
K
BP5S
BP6S
E
BP6S
E
BP5S
E
CP-1
B
FILTER EFFLUENT
RATE CONTROLLER
CP-1
B
B
CP-1
FCP
AA
FCP
3
**
H
WTCP
A29
B
E
**
J
FCP
X
K
CHEMICAL FEED
CONTROL PANEL
(CFCP)
A26
CP-1
D
J
11
11
CP-1
Y
E
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
E4
.d
wg
, 8
/1
5/2
01
9 2
:2
0:1
1 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3
2 2 2
2
2
2
22
2
2
2
2 2 22
2
2
2
2
2
2 22 2
1
11
S
S
S
S
S
S S
1
S
SS
S
S
4
4
CIT
Y O
F C
RO
SW
EL
L
SA
NIL
AC
C
OU
NT
Y, M
IC
HIG
AN
BID
P
AC
KA
GE
N
O.3, W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
AUGUST 2019
834330
F&V PROJECT NO.
DESIGN
TEAM:
DRAWING INFORMATION:
CHECK BY:
REVISION:
2125 Ridgewood Dr, Suite 101
P: 989.837.3280
F: 989.837.3290
Midland, MI 48642
DESIGN. BUILD. OPERATE.
PROJ MNGR:
DESIGNED BY:
DRAWN BY:
1Issu
ed
fo
r B
id
s08/05/19
DR
S
LIGHTING & HVAC PLAN
SCALE: 1/4"=1'-0"
LIGHTING/HVAC FIXTURE SCHEDULE
TYPE DESCRIPTION
TOTAL
W
LAMP
MOUNTING
NO W TYPE
1
HOLOPHONE HLW
PC2-P10-40K-AS-T3M-B2SDP-80CRI-PE-EM
50 2 25
120V LED WAL PAK
w/PHOTOCELL AND COLD
WEATHER BATTERY
BACKUP
EXTERIOR - MOUNT AS
SHOWN ON PLANS
2
HOLOPHONE HZL
1N-L48-7000LM-FST-MVOLT-40K-80CRI-E7W-WH
67 1 67
120V LED w/BATTERY
BACKUP FOR FIXTURES
MARKED "EM" ON PLANS
NC INDICATES WIRE AS
NIGHT LIGHT
CEILING MOUNT 4'-0" STRIP
LED
3
LITHONIA
DSXO-LED-20-C-700-40K-T4M-MVOLT-SPA-PER-DDBXD-D
LL12-1.5
POLE LITHONIA SSA 30-DM19AS
91 1 91 120V LED
SITE LIGHTS 30' BRONZE
ALUMINUM POLE
4 SURELITES LPX 5 1 5 RED LED OVER DOORWAY
SHEET NOTES:
1 SEE SINGLE LINE DIAGRAM, SHEET E3 FOR CONDUCTOR AND CONDUIT SIZES.
2 INSTRUMENTATION CONDUIT HOME RUNS MAY BE COMBINED INTO THE FOLLOWING GROUPS:
ANALOG - 4-20mA
DIGITAL - DRY CONTACT 24VDC
CONTROL - 120VAC POWERED
DO NOT INTERMIX GROUPS IN SAME CONDUIT
3 POWER NEW LIGHTING FIXTURES FROM EXISTING CONDUIT. PROVIDE NEW CONDUCTORS.
4 ADJUST LIGHTING FIXTURE LOCATIONS AS NECESSARY TO ACCOMMODATE PROCESS PIPING.
5 PROVIDE NEW GFI, 20 AMP RECEPTACLES AND CONDUCTORS USING EXISTING CONDUIT AND OUTLET
BOXES IN PUMP ROOM.
6 REUSE EXISTING RECEPTACLE PVC OUTLET BOXES, LIGHT SWITCH OUTLET BOXES AND ASSOCIATED
CONDUIT. PROVIDE NEW CONDUCTORS, SWITCHES AND RECEPTACLES AS SHOWN ON PLANS. CLEAN
CONDUITS w/MANDREL AND CLOTH PRIOR TO PULLING NEW CONDUCTORS.
7 PROVIDE PVC SCH. 80 CONDUIT AND OUTLET BOXES IN CHEMICAL ROOM.
8 REUSE EXISTING HVAC CONDUIT AND OUTLET BOXES WHERE CONCEALED. PROVIDE NEW CONDUIT
AND OUTLET BOXES WHERE EXPOSED. PROVIDE NEW SWITCHES AND CONDUCTORS AS SHOWN ON
PLANS.
9 REFER TO SHEET M1 FOR HVAC ELECTRICAL REQUIREMENTS. PROVIDE CONDUITS, CONDUCTORS
AND DISCONNECT SWITCHES FOR GAS UNIT HEATERS, EXHAUST FANS, MOTORIZED DAMPERS AND
THERMOSTATS.
10 CONDUIT AND WIRE MUST BE RUN ABOVE REMOVABLE PANELS.
11 PARKING LOT LIGHTING, CONDUIT, WIRE PHOTOCELL AND CONTACTOR BY OWNER.
LIGHTING PANEL LP-A VOLTAGE 120/208 3Ø, 4W .
LOCATION WATER TREATMENT PLANT MAIN C.B. 50A .
SURFACE ENCLOSURE BUS SIZE 100A .
CIRCUIT LOADS
DESCRIPTION
VOLT AMP. DESCRIPTION LOADS CIRCUIT
NO. AMPS POLE VA LTS. REC. OTH. ØA ØB ØC LTS. REC. OTH. VA POLE AMPS NO
1 15 1 50 1 AIT-02 100 FIT-02 1 50 1 15 2
3 20 1 100 1 WTCP 150 FIT-06 1 50 1 15 4
5 30 1 1000 1 FCP 1000 LAB RECEPTACLES 2 180 1 20 6
7 15 1 180 1 GEN RECEPTACLE 480 20 8
9 20 1 100 1 GEN BATTERY CHARGER 1600 GEN BLOCK HEATER 1 1500 1 20 10
11 20 1 52 7 FILTER ROOM LIGHTS 728 INDIVIDUAL ROOM LIGHTS 7 52 1 20 12
13 20 1 52 10 FILTER ROOM LIGHTS 880 EXTERIOR RECEPTACLES 1 180 1 20 14
15 20 1 91 4 EXTERIOR LIGHTS/LIGHTING CONTROL 1164 FILTER ROOM RECEPTACLES 5 180 1 20 16*
17 20 1 50 1 AIT-01 950 FILTER ROOM RECEPTACLES 5 1 180 1 20 18*
19 20 1 500 1 DEHUMIDIFIER 550 FIT-05 1 50 1 15 20
21 20 1 200 2 EF-1/EF-2 250 AIT-03 1 50 1 15 22
23 20 2 1000 1 UH-3 1100 EPCP 1 100 1 20 24
25 20 1000 1 1100 CFCP 1 100 1 20 26
27 20 6 180 LAB/BATH/MEC REC 380 EF-5 2 200 1 20 28
29 15 1 50 1 FIT-01 50 30
31 20 1 5 2 EXIT LIGHTS 10 32
33 34
35 36
37 38
39 40
41 42
* PROVIDE GFI BREAKER ** LOCKOUT ATTACHMENT TOTALS 3120 3544 3828 * PROVIDE GFI BREAKER **LOCAKOUT ATTACHMENT
A15
A27
A14
A27
A27
A16
A16
A16
A15
A18A14
WP
GFI
A15
A18
A18
A18
A12
A15
A13
WP
GFI
GFI
A27
EF-3
A12
A16
A12
GFI
A26
A26
A12
A28
A28
GFI
WP
EM
NL
EM
NL
3
834330_E5
081519 davet
LIG
HT
IN
G &
H
VA
C P
LA
N
E5
GOB
EEH
DCT
3
NL
L w/MOTORIZED DAMPER
MANUAL MOTOR STARTER
1P
20A
120 VAC FROM "LP-A"
FC
1
NOTES:
SEE M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.
EXHAUST FAN EF-2 WIRING DIAGRAM
1
NL
1P
20A
120 VAC FROM "LP-A"
EXHAUST FAN EF-4 WIRING DIAGRAM
1
EF
1
NOTES:
REFER TO M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.
CHLORINE ALARM
R
FC
R
NL
L w/MOTORIZED DAMPER
EF MANUAL MOTOR STARTER
1P
20A
120 VAC FROM "LP-A"
FC
1
FC
EXHAUST FAN EF-1 WIRING DIAGRAM
L w/MOTORIZED DAMPER
1
NOTES:
SEE M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.
1
EF-2
CONTROLS
L2
EF-4 EF-5
A29/31
WH-1
UH-1
C1
UH-1
1
A21/EF-2
CONTROLS
A21/EF-1
CONTROLS
m
m
mm
A32
MDP
1
EF-1
FUSED DISCONNECT
FUSED DISCONNECT
FUSED DISCONNECT
MDP
1
UH-3
UH-2
FUSED DISCONNECT
A23/25
A21
EF-1
A28
m
MDP
C1L1
EF-1
CONTROLS
1
A19
EF-1
CONTROLS
MDP
A18
EM
NL
A11
NORTH
10 10 10
DOOR SWITCH
EF MANUAL MOTOR STARTER
NL
1P
20A
120 VAC FROM "LP-A"
EXHAUST FAN EF-4 WIRING DIAGRAM
1
EF
1
NOTES:
REFER TO M SHEETS FOR CONTROL POINTS AND EQUIPMENT LOCATIONS.
1
1
L1
MDP
1
2
Ad
den
du
m 1
08/15/19
DR
S
LIGHTING CONTACTOR (LC)
11
A15
K
A31
A31
L w/MOTORIZED DAMPER
EF
M:\P
ro
j8
33
00
1-8
35
00
0\8
34
33
0 C
ro
sw
ell IC
E G
ra
nt 2
01
8\C
ad
\P
ln
s\8
34
33
0_
E5
.d
wg
, 8
/1
5/2
01
9 1
2:2
4:5
0 P
M, d
ave
t, D
WG
T
o P
DF
.p
c3