GSM/EDGE BSS, Rel. RG10(BSS), Operating Documentation, Issue 07

Reference

Disturbance Printouts (1000-1999)

DN9813048

Issue 18-2Approval Date 2009-12-17

Confidential

Page 2: Descrption alarms - GSM NOKIA - 1000 à 1999

2 DN9813048Issue 18-2

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2011. All rights reserved

f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.

The safety information is provided in the Safety Information section in the “Legal, Safety and Environmental Information” part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.

Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.

Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal, Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-satzes.

Page 3: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 3

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

Table of contentsThis document has 241 pages.

Summary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2 Disturbance printout parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3 1001 UNIT RESTARTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4 1002 RAM FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

5 1003 PARITY ERROR IN RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

6 1004 COMMUNICATION ERROR BETWEEN PROGRAM BLOCKS. . 21

7 1005 PLUG-IN UNIT RESTARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

8 1007 RESTARTED PROGRAM BLOCK . . . . . . . . . . . . . . . . . . . . . . . . 23

9 1008 MML PROGRAM RESTARTED . . . . . . . . . . . . . . . . . . . . . . . . . . 24

10 1010 NO RESPONSE TO UNIT SUPERVISION MESSAGE . . . . . . . . 25

11 1012 EXCESSIVE RESTARTS OF UNIT . . . . . . . . . . . . . . . . . . . . . . . 26

12 1014 PROCESSOR LOAD RATE ALARM LIMIT EXCEEDED . . . . . . . 27

13 1015 OPERATING SYSTEM ERROR COUNTER INCREASED . . . . . 28

14 1016 MB INTERFACE FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

15 1018 PROGRAM BLOCK COMMUNICATION ERROR . . . . . . . . . . . . 30

16 1019 PROGRAM BLOCK ACTION FAILURE . . . . . . . . . . . . . . . . . . . . 31

17 1020 PROGRAM BLOCK START UP FAILURE . . . . . . . . . . . . . . . . . . 32

18 1021 PROGRAM BLOCK REWARMING STARTED. . . . . . . . . . . . . . . 34

19 1022 PROGRAM BLOCK WARMUP FAILURE. . . . . . . . . . . . . . . . . . . 35

20 1023 EXCESSIVE DISTURBANCES IN SUPERVISION . . . . . . . . . . . 36

21 1024 HAND PROCESS ERROR IN PROGRAM BLOCK . . . . . . . . . . . 37

22 1028 RESTARTED PROGRAM BLOCK IN PREPROCESSOR UNIT . 39

23 1029 SCCP STP MESSAGE PREVENTION. . . . . . . . . . . . . . . . . . . . . 40

24 1033 OSI CLNS CONFIGURATION FAILED . . . . . . . . . . . . . . . . . . . . 43

25 1034 MAXIMUM SEQUENCE NUMBER OF OSI CLNS EXCEEDED . 44

26 1035 UPU MESSAGE RECEIVED . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

27 1044 ERROR IN SWITCH COMPARE TEST . . . . . . . . . . . . . . . . . . . . 47

28 1045 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

29 1047 NO RESPONSE FROM CONTROLLER OF SWITCHING NET-WORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 4: Descrption alarms - GSM NOKIA - 1000 à 1999

4 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

30 1048 CONTROLLER OF SWITCHING NETWORK RESTARTED. . . . . 52

31 1049 SEMIPERMANENT MULTICHANNEL CONNECTION MISSING . 53

32 1055 TCAP TRANSACTION FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . 54

33 1056 MESSAGE FROM NETWORK TO UNKNOWN SUBSYSTEM . . . 56

34 1058 ERROR IN SMUX PLUG-IN UNIT . . . . . . . . . . . . . . . . . . . . . . . . . 58

35 1061 ERROR IN SWITCH COMPARE TEST. . . . . . . . . . . . . . . . . . . . . 59

36 1062 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

37 1064 UNIT UPDATE FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

38 1065 DISK UPDATE FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

39 1070 CCS7 PROGRAM BLOCK DATA ERROR . . . . . . . . . . . . . . . . . . 63

40 1071 PROCESSOR TIME SHORTAGE . . . . . . . . . . . . . . . . . . . . . . . . . 64

41 1072 SIGNALLING LINK OUT OF SERVICE . . . . . . . . . . . . . . . . . . . . . 66

42 1076 FORCED LIGHTWEIGHT SCHEDULING . . . . . . . . . . . . . . . . . . . 69

43 1077 FREE STACK SIZE BELOW LIMIT . . . . . . . . . . . . . . . . . . . . . . . . 70

44 1078 PROCESS EXCEPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

45 1080 PROCESS STOPPED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

46 1082 HAND USAGE LIMIT EXCEEDED . . . . . . . . . . . . . . . . . . . . . . . . 75

47 1083 SEMAPHORE USE ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

48 1089 DYNAMIC LDT SLOTS EXHAUSTED. . . . . . . . . . . . . . . . . . . . . . 77

49 1090 BUFFER HANDLE ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

50 1092 COMMUNICATION FAILURE IN FIELD REPORTING . . . . . . . . . 79

51 1093 OUTPUT FAILURE IN FIELD REPORTING . . . . . . . . . . . . . . . . . 80

52 1095 TRAFFIC MEASUREMENT OUTPUT FAILURE. . . . . . . . . . . . . . 82

53 1098 TOO LONG MESSAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

54 1103 SIGNALLING MEASUREMENT REPORT LOST . . . . . . . . . . . . . 85

55 1105 LINE SIGNALLING RECEIVE OVERLOAD. . . . . . . . . . . . . . . . . . 88

56 1125 TRIAL CONFIGURATION DELETED . . . . . . . . . . . . . . . . . . . . . . 89

57 1128 EXCESSIVE DISTURBANCES IN FILE LOADING . . . . . . . . . . . . 90

58 1136 SIGNALLING MESSAGE DISTRIBUTION ERROR . . . . . . . . . . . 91

59 1137 INCORRECT SIGNALLING MESSAGE FROM SIGNALLING TER-MINAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

60 1140 FREE LDT SLOT COUNT BELOW LIMIT . . . . . . . . . . . . . . . . . . . 94

61 1141 DELAY BUFFER OVERFLOW IN SIGNALLING TERMINAL . . . . 96

Page 5: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 5

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

62 1142 FAMILY MEMORY USAGE SUPERVISION LIMIT EXCEEDED . 97

63 1143 AMOUNT OF FREE MEMORY REDUCED . . . . . . . . . . . . . . . . . 99

64 1144 FREE BUFFER HEADERS EXHAUSTING . . . . . . . . . . . . . . . . 100

65 1147 MESSAGE QUEUE OVERFLOW. . . . . . . . . . . . . . . . . . . . . . . . 101

66 1148 EXCESSIVE TRAPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

67 1162 FILE SYSTEM COMMUNICATION ERROR . . . . . . . . . . . . . . . 104

68 1165 BUFFER ALLOCATION FAILED . . . . . . . . . . . . . . . . . . . . . . . . 105

69 1169 FREEZING PERIOD OF SS7 REPORTING LOST . . . . . . . . . . 107

70 1178 PREPROCESSOR UNIT DISTURBANCE . . . . . . . . . . . . . . . . . 109

71 1182 PREPROCESSOR UNIT RESTARTED . . . . . . . . . . . . . . . . . . . 110

72 1190 EXCESSIVE ERRORS IN SCP . . . . . . . . . . . . . . . . . . . . . . . . . 111

73 1200 ACTOR HAS FAILED TO REGISTER TO THE SUPERVISION 112

74 1204 WATCHDOG CAUSES UNIT RESTART . . . . . . . . . . . . . . . . . . 113

75 1207 UNITS WORKING STATE DATA CORRUPTED IN THE SYSTEM . 114

76 1210 PHASE ADVANCE OF TIMING SIGNAL CHANGED. . . . . . . . . 115

77 1220 HANDLING OF MEASUREMENT DEFINITION FILE FAILED. . 117

78 1221 STATISTICAL MEASUREMENT REPORT OUTPUT FAILED. . 119

79 1222 DATA WRITING VIA VDS DEVICE FAILED. . . . . . . . . . . . . . . . 121

80 1228 UNIT SUPERVISION NOT FUNCTIONING . . . . . . . . . . . . . . . . 122

81 1234 UPDATE OF PASSWORD VALIDITY TIME FAILED . . . . . . . . . 123

82 1240 SCCP DISTURBANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

83 1241 SCCP GLOBAL TITLE TRANSLATION ANALYSIS FILE ERROR . 127

84 1242 SCCP GLOBAL TITLE TRANSLATION RESULT FILE ERROR 132

85 1244 RUNNING OUT OF MESSAGE BUFFERS . . . . . . . . . . . . . . . . 136

86 1249 DATABASE DISK COPY HAS EXCEEDED MAXIMUM ALLOWED AGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138

87 1250 DATA LINK LAYER PROTOCOL MISMATCH . . . . . . . . . . . . . . 139

88 1251 EXCESSIVE RETRANSMISSIONS ON DATA LINK CONNECTION140

89 1252 EXCESSIVE ERROR RATE ON DATA LINK CONNECTION . . 142

90 1253 NO RESPONSE FROM PRIMARY RATE ACCESS TERMINAL 143

91 1254 UNSOLICITED DATA LINK RE-ESTABLISHMENT. . . . . . . . . . 144

92 1255 PRIMARY RATE ACCESS MESSAGE DISTRIBUTION ERROR145

Page 6: Descrption alarms - GSM NOKIA - 1000 à 1999

6 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

93 1256 INCORRECT PRD MESSAGE FROM PRIMARY RATE ACCESS TERMINAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

94 1260 X.25/ETHERNET DATA TERMINAL SPONTANEOUS RESTART . .147

95 1261 OSI CHANNEL GROUP UNREACHABLE . . . . . . . . . . . . . . . . . 148

96 1262 OSI SERVICE PROVIDER RESET . . . . . . . . . . . . . . . . . . . . . . . 149

97 1263 OSI SERVICE PROVIDER INTERFACE ERROR. . . . . . . . . . . . 150

98 1264 OSI INCOMING CALL DENIED. . . . . . . . . . . . . . . . . . . . . . . . . . 151

99 1273 ASP ACTIVATION FAILED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152

100 1280 INTERNAL COMMUNICATION CHANNEL FAILURE. . . . . . . . . 161

101 1282 ASSOCIATION PARAMETER FAILURE. . . . . . . . . . . . . . . . . . . 163

102 1293 SCCP GT SCREENING APPLIED . . . . . . . . . . . . . . . . . . . . . . . 165

103 1300 SUPERVISION CONNECTION TO UNIT LOST . . . . . . . . . . . . . 169

104 1301 PCU DIGITAL SIGNAL PROCESSOR RESTART . . . . . . . . . . . 170

105 1302 PAGING OVERLOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171

106 1339 ACTIVE FRAMER UNIT FAILURE . . . . . . . . . . . . . . . . . . . . . . . 172

107 1340 HOTLINK FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174

108 1347 CS PAGING COORDINATION ACTIVATION/DEACTIVATION FAILED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175

109 1400 AFS RESTARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177

110 1423 NO RESPONSE FROM MAIN CLOCK . . . . . . . . . . . . . . . . . . . . 178

111 1425 OVERFLOW IN ALARM BUFFERING. . . . . . . . . . . . . . . . . . . . . 179

112 1431 MMI SYSTEM OVERLOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180

113 1432 DISTURBANCE IN COMMAND CALENDAR . . . . . . . . . . . . . . . 181

114 1548 MTP CONFUSION MESSAGE RECEIVED. . . . . . . . . . . . . . . . . 188

115 1557 EVENT HANDLER CANNOT WORK PROPERLY DUE TO FILE SERVICE FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189

116 1569 CRITICAL LIMIT IN SECURITY REPORTING REACHED . . . . . 190

117 1570 SECURITY LOG ALARM LIMIT REACHED . . . . . . . . . . . . . . . . 191

118 1578 CONFUSION IN BSSMAP SIGNALING . . . . . . . . . . . . . . . . . . . 192

119 1580 GLOBAL RESET FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

120 1582 CONNECTION OR RELEASE ERROR. . . . . . . . . . . . . . . . . . . . 194

121 1583 LAPD MSG DISTRIBUTION PROBLEM . . . . . . . . . . . . . . . . . . . 196

122 1585 ABNORMAL A INTERFACE CIRCUIT RELEASE. . . . . . . . . . . . 197

123 1590 ALARM SYSTEM MESSAGE SENDING BUFFER FULL . . . . . . 199

Page 7: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 7

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

124 1597 I/O DEVICE FOUND FAULTY BY ALARM SYSTEM . . . . . . . . . 200

125 1598 UNIT FOUND FAULTY BY ALARM SYSTEM . . . . . . . . . . . . . . 201

126 1623 ERROR DURING SUPERVISION . . . . . . . . . . . . . . . . . . . . . . . 202

127 1630 RAM FAILURE IN SYNCHRONIZATION UNIT . . . . . . . . . . . . . 203

128 1660 UPDATE NUMBER MISMATCH. . . . . . . . . . . . . . . . . . . . . . . . . 204

129 1661 DATABASE MANAGER IN FATAL ERROR STATE . . . . . . . . . 205

130 1662 DATABASE LOADING ERROR . . . . . . . . . . . . . . . . . . . . . . . . . 206

131 1663 HAND RESERVATION ERROR IN DATABASE MANAGER. . . 208

132 1682 SCDFLE UPDATE FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . 209

133 1683 FAULTY UNIT SP-EX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210

134 1684 SPARE UNIT WARMUP FAILURE. . . . . . . . . . . . . . . . . . . . . . . 211

135 1685 UNIT RESTART FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212

136 1687 RECOVERY ACTION FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . 213

137 1688 FAILURE IN CALL CLEARING. . . . . . . . . . . . . . . . . . . . . . . . . . 214

138 1800 SCSI ADDRESS ILLEGAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215

139 1801 MASS MEMORY FILE BACKUP FAILURE . . . . . . . . . . . . . . . . 216

140 1802 BACKUP COPY LOG FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . 217

141 1804 IP ROUTING RESOURCE SHORTAGE . . . . . . . . . . . . . . . . . . 219

142 1806 PRINTER SPOOLER DISABLED. . . . . . . . . . . . . . . . . . . . . . . . 220

143 1809 IP CONFIGURATION INQUIRY SERVICE FAILED. . . . . . . . . . 221

144 1850 BTS TEST REPORT PRINTOUT FAILED . . . . . . . . . . . . . . . . . 223

145 1860 DISK DISTURBANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225

146 1881 TAPI FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226

147 1882 DMADI FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227

148 1884 LABEL PARAMETER FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . 228

149 1885 ERROR IN WRITING DATA TO MAGNETIC TAPE. . . . . . . . . . 229

150 1886 ERROR IN TAPE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . 230

151 1887 BLOCK COUNTER FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . . 231

152 1891 AS7 RESTARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232

153 1893 O&M CHANNEL SEND OVERLOAD . . . . . . . . . . . . . . . . . . . . . 233

154 1894 NO RESPONSE TO AS7 SUPERVISION MESSAGE . . . . . . . . 234

155 1895 DISTURBANCE IN O&M CHANNEL . . . . . . . . . . . . . . . . . . . . . 235

156 1900 DEGRADED SLIP FREQUENCY . . . . . . . . . . . . . . . . . . . . . . . . 236

Page 8: Descrption alarms - GSM NOKIA - 1000 à 1999

8 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941dConfidential

157 1901 ET RESTARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237

158 1910 COMMUNICATION FAILURE WITH TRX . . . . . . . . . . . . . . . . . . 238

159 1911 INVALID URGENCY LEVEL IN TRANSMISSION ALARM . . . . . 239

160 1915 TCSM CLOCK DISTURBANCE. . . . . . . . . . . . . . . . . . . . . . . . . . 241

Page 9: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 9

Disturbance Printouts (1000-1999) Summary of Changes

Id:0900d805806a941aConfidential

Summary of ChangesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

Changes made between issues 18-2 and 18-1New alarmsNew alarm 1347 CS PAGING COORDINATION ACTIVATION/DEACTIVATION FAILED has been added.

Changes made between issues 18-1 and 18-0Modified alarmsThe instructions of the alarm 1809 IP CONFIGURATION INQUIRY SERVICE FAILED have been modified.

Changes made between issues 18-0 and 17-1New alarmsNew alarm 1339 ACTIVE FRAMER UNIT FAILURE has been added.

Modified alarmsThe following alarms have been updated:

• 1071 PROCESSOR TIME SHORTAGE • 1080 PROCESS STOPPED • 1340 HOTLINK FAILURE • 1583 LAPD MSG DISTRIBUTION PROBLEM

Changes made between issues 17-1and 17-0Modified alarmsInformation on the typical causes for refusing the CONFUSION message has been updated in the Supplementary information fields of the printout 1578 CONFUSION IN BSSMAP SIGNALING.

Page 10: Descrption alarms - GSM NOKIA - 1000 à 1999

10 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

List of Alarms

1 List of Alarms1001 UNIT RESTARTED

1002 RAM FAILURE

1003 PARITY ERROR IN RAM

1004 COMMUNICATION ERROR BETWEEN PROGRAM BLOCKS

1005 PLUG-IN UNIT RESTARTED

1007 RESTARTED PROGRAM BLOCK

1008 MML PROGRAM RESTARTED

1010 NO RESPONSE TO UNIT SUPERVISION MESSAGE

1012 EXCESSIVE RESTARTS OF UNIT

1014 PROCESSOR LOAD RATE ALARM LIMIT EXCEEDED

1015 OPERATING SYSTEM ERROR COUNTER INCREASED

1016 MB INTERFACE FAILURE

1018 PROGRAM BLOCK COMMUNICATION ERROR

1019 PROGRAM BLOCK ACTION FAILURE

1020 PROGRAM BLOCK START UP FAILURE

1021 PROGRAM BLOCK REWARMING STARTED

1022 PROGRAM BLOCK WARMUP FAILURE

1023 EXCESSIVE DISTURBANCES IN SUPERVISION

1024 HAND PROCESS ERROR IN PROGRAM BLOCK

1028 RESTARTED PROGRAM BLOCK IN PREPROCESSOR UNIT

1029 SCCP STP MESSAGE PREVENTION

1033 OSI CLNS CONFIGURATION FAILED

1034 MAXIMUM SEQUENCE NUMBER OF OSI CLNS EXCEEDED

1035 UPU MESSAGE RECEIVED

1044 ERROR IN SWITCH COMPARE TEST

1045 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORY

1047 NO RESPONSE FROM CONTROLLER OF SWITCHING NETWORK

1048 CONTROLLER OF SWITCHING NETWORK RESTARTED

1049 SEMIPERMANENT MULTICHANNEL CONNECTION MISSING

1055 TCAP TRANSACTION FAILURE

1056 MESSAGE FROM NETWORK TO UNKNOWN SUBSYSTEM

1058 ERROR IN SMUX PLUG-IN UNIT

1061 ERROR IN SWITCH COMPARE TEST

1062 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORY

1064 UNIT UPDATE FAILURE

1065 DISK UPDATE FAILURE

Page 11: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 11

Disturbance Printouts (1000-1999) List of Alarms

Id:0900d805806a941aConfidential

1070 CCS7 PROGRAM BLOCK DATA ERROR

1071 PROCESSOR TIME SHORTAGE

1072 SIGNALLING LINK OUT OF SERVICE

1076 FORCED LIGHTWEIGHT SCHEDULING

1077 FREE STACK SIZE BELOW LIMIT

1078 PROCESS EXCEPTION

1080 PROCESS STOPPED

1082 HAND USAGE LIMIT EXCEEDED

1083 SEMAPHORE USE ERROR

1089 DYNAMIC LDT SLOTS EXHAUSTED

1090 BUFFER HANDLE ERROR

1092 COMMUNICATION FAILURE IN FIELD REPORTING

1093 OUTPUT FAILURE IN FIELD REPORTING

1095 TRAFFIC MEASUREMENT OUTPUT FAILURE

1098 TOO LONG MESSAGE

1103 SIGNALLING MEASUREMENT REPORT LOST

1105 LINE SIGNALLING RECEIVE OVERLOAD

1125 TRIAL CONFIGURATION DELETED

1128 EXCESSIVE DISTURBANCES IN FILE LOADING

1136 SIGNALLING MESSAGE DISTRIBUTION ERROR

1137 INCORRECT SIGNALLING MESSAGE FROM SIGNALLING TERMINAL

1140 FREE LDT SLOT COUNT BELOW LIMIT

1141 DELAY BUFFER OVERFLOW IN SIGNALLING TERMINAL

1142 FAMILY MEMORY USAGE SUPERVISION LIMIT EXCEEDED

1143 AMOUNT OF FREE MEMORY REDUCED

1144 FREE BUFFER HEADERS EXHAUSTING

1147 MESSAGE QUEUE OVERFLOW

1148 EXCESSIVE TRAPS

1162 FILE SYSTEM COMMUNICATION ERROR

1165 BUFFER ALLOCATION FAILED

1169 FREEZING PERIOD OF SS7 REPORTING LOST

1178 PREPROCESSOR UNIT DISTURBANCE

1182 PREPROCESSOR UNIT RESTARTED

1190 EXCESSIVE ERRORS IN SCP

1200 ACTOR HAS FAILED TO REGISTER TO THE SUPERVISION

1204 WATCHDOG CAUSES UNIT RESTART

1207 UNITS WORKING STATE DATA CORRUPTED IN THE SYSTEM

1210 PHASE ADVANCE OF TIMING SIGNAL CHANGED

Page 12: Descrption alarms - GSM NOKIA - 1000 à 1999

12 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

List of Alarms

1220 HANDLING OF MEASUREMENT DEFINITION FILE FAILED

1221 STATISTICAL MEASUREMENT REPORT OUTPUT FAILED

1222 DATA WRITING VIA VDS DEVICE FAILED

1228 UNIT SUPERVISION NOT FUNCTIONING

1234 UPDATE OF PASSWORD VALIDITY TIME FAILED

1240 SCCP DISTURBANCE

1241 SCCP GLOBAL TITLE TRANSLATION ANALYSIS FILE ERROR

1242 SCCP GLOBAL TITLE TRANSLATION RESULT FILE ERROR

1244 RUNNING OUT OF MESSAGE BUFFERS

1249 DATABASE DISK COPY HAS EXCEEDED MAXIMUM ALLOWED AGE

1250 DATA LINK LAYER PROTOCOL MISMATCH

1251 EXCESSIVE RETRANSMISSIONS ON DATA LINK CONNECTION

1252 EXCESSIVE ERROR RATE ON DATA LINK CONNECTION

1253 NO RESPONSE FROM PRIMARY RATE ACCESS TERMINAL

1254 UNSOLICITED DATA LINK RE-ESTABLISHMENT

1255 PRIMARY RATE ACCESS MESSAGE DISTRIBUTION ERROR

1256 INCORRECT PRD MESSAGE FROM PRIMARY RATE ACCESS TERMINAL

1260 X.25/ETHERNET DATA TERMINAL SPONTANEOUS RESTART

1261 OSI CHANNEL GROUP UNREACHABLE

1262 OSI SERVICE PROVIDER RESET

1263 OSI SERVICE PROVIDER INTERFACE ERROR

1264 OSI INCOMING CALL DENIED

1273 ASP ACTIVATION FAILED

1280 INTERNAL COMMUNICATION CHANNEL FAILURE

1282 ASSOCIATION PARAMETER FAILURE

1293 SCCP GT SCREENING APPLIED

1300 SUPERVISION CONNECTION TO UNIT LOST

1301 PCU DIGITAL SIGNAL PROCESSOR RESTART

1302 PAGING OVERLOAD

1339 ACTIVE FRAMER UNIT FAILURE

1340 HOTLINK FAILURE

1347 CS PAGING COORDINATION ACTIVATION/DEACTIVATION FAILED

1400 AFS RESTARTED

1423 NO RESPONSE FROM MAIN CLOCK

1425 OVERFLOW IN ALARM BUFFERING

1431 MMI SYSTEM OVERLOAD

1432 DISTURBANCE IN COMMAND CALENDAR

Page 13: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 13

Disturbance Printouts (1000-1999) List of Alarms

Id:0900d805806a941aConfidential

1548 MTP CONFUSION MESSAGE RECEIVED

1557 EVENT HANDLER CANNOT WORK PROPERLY DUE TO FILE SERVICE FAILURE

1569 CRITICAL LIMIT IN SECURITY REPORTING REACHED

1570 SECURITY LOG ALARM LIMIT REACHED

1578 CONFUSION IN BSSMAP SIGNALING

1580 GLOBAL RESET FAILURE

1582 CONNECTION OR RELEASE ERROR

1583 LAPD MSG DISTRIBUTION PROBLEM

1585 ABNORMAL A INTERFACE CIRCUIT RELEASE

1590 ALARM SYSTEM MESSAGE SENDING BUFFER FULL

1597 I/O DEVICE FOUND FAULTY BY ALARM SYSTEM

1598 UNIT FOUND FAULTY BY ALARM SYSTEM

1623 ERROR DURING SUPERVISION

1630 RAM FAILURE IN SYNCHRONIZATION UNIT

1660 UPDATE NUMBER MISMATCH

1661 DATABASE MANAGER IN FATAL ERROR STATE

1662 DATABASE LOADING ERROR

1663 HAND RESERVATION ERROR IN DATABASE MANAGER

1682 SCDFLE UPDATE FAILURE

1683 FAULTY UNIT SP-EX

1684 SPARE UNIT WARMUP FAILURE

1685 UNIT RESTART FAILURE

1687 RECOVERY ACTION FAILURE

1688 FAILURE IN CALL CLEARING

1800 SCSI ADDRESS ILLEGAL

1801 MASS MEMORY FILE BACKUP FAILURE

1802 BACKUP COPY LOG FAILURE

1804 IP ROUTING RESOURCE SHORTAGE

1806 PRINTER SPOOLER DISABLED

1809 IP CONFIGURATION INQUIRY SERVICE FAILED

1850 BTS TEST REPORT PRINTOUT FAILED

1860 DISK DISTURBANCE

1881 TAPI FAILURE

1882 DMADI FAILURE

1884 LABEL PARAMETER FAILURE

1885 ERROR IN WRITING DATA TO MAGNETIC TAPE

1886 ERROR IN TAPE OPERATION

1887 BLOCK COUNTER FAILURE

Page 14: Descrption alarms - GSM NOKIA - 1000 à 1999

14 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

List of Alarms

1891 AS7 RESTARTED

1893 O&M CHANNEL SEND OVERLOAD

1894 NO RESPONSE TO AS7 SUPERVISION MESSAGE

1895 DISTURBANCE IN O&M CHANNEL

1900 DEGRADED SLIP FREQUENCY

1901 ET RESTARTED

1910 COMMUNICATION FAILURE WITH TRX

1911 INVALID URGENCY LEVEL IN TRANSMISSION ALARM

1915 TCSM CLOCK DISTURBANCE

Page 15: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 15

Disturbance Printouts (1000-1999) Disturbance printout parameters

Id:0900d805806a941aConfidential

2 Disturbance printout parameters1200 DISTUR NONE 00:00 00:00 00:00 00:01:00 1204 DISTUR NONE 00:00 00:00 00:00 00:00:15 1207 DISTUR NONE 00:00 00:00 00:00 00:00:50 1210 DISTUR NONE 00:00 00:00 00:00 00:00:15 1220 DISTUR NONE 00:00 00:00 00:00 00:00:15 1221 DISTUR NONE 00:00 00:00 00:00 00:00:15 1222 DISTUR NONE 00:00 00:00 00:00 00:00:15 1228 DISTUR NONE 00:00 00:00 00:00 00:00:50 1234 DISTUR NONE 00:00 00:00 00:00 00:00:15 1240 DISTUR NONE 00:00 00:00 00:00 00:00:15 1241 DISTUR NONE 00:00 00:00 00:00 00:00:15 1242 DISTUR NONE 00:00 00:00 00:00 00:00:15 1244 DISTUR NONE 00:00 00:00 00:00 00:00:15 1249 DISTUR NONE 00:00 00:00 00:00 00:00:15 1250 DISTUR NONE 00:00 00:00 00:00 00:05:00 1251 DISTUR NONE 00:00 00:00 00:00 00:05:00 1252 DISTUR NONE 00:00 00:00 00:00 00:05:00 1253 DISTUR NONE 00:00 00:00 00:00 00:00:15 1254 DISTUR NONE 00:00 00:00 00:00 00:05:00 1255 DISTUR NONE 00:00 00:00 00:00 00:00:15 1256 DISTUR NONE 00:00 00:00 00:00 00:00:15 1260 DISTUR NONE 00:00 00:00 00:00 00:00:15 1261 DISTUR NONE 00:00 00:00 00:00 00:00:15 1262 DISTUR NONE 00:00 00:00 00:00 00:00:15 1263 DISTUR NONE 00:00 00:00 00:00 00:00:15 1264 DISTUR NONE 00:00 00:00 00:00 00:05:00 1273 DISTUR NONE 00:00 00:00 00:00 00:00:15 1280 DISTUR NONE 00:00 00:00 00:00 00:04:00 1282 DISTUR NONE 00:00 00:00 00:00 00:00:15 1293 DISTUR NONE 00:00 00:00 00:00 00:00:15 1300 DISTUR NONE 00:00 00:00 00:00 00:00:15 1301 DISTUR NONE 00:00 00:00 00:00 00:00:15 1302 DISTUR NONE 00:00 00:00 00:00 00:00:15 1339 DISTUR NONE 00:00 00:00 00:00 00:00:15 1340 DISTUR NONE 00:00 00:00 00:00 00:00:15 1347 DISTUR NONE 00:00 00:00 00:00 00:00:15 1400 DISTUR NONE 00:00 00:00 00:00 00:00:15 1423 DISTUR NONE 00:00 00:00 00:00 00:00:15 1425 DISTUR NONE 00:00 00:00 00:00 00:00:15 1431 DISTUR NONE 00:00 00:00 00:00 00:00:15 1432 DISTUR NONE 00:00 00:00 00:00 00:00:15 1548 DISTUR NONE 00:00 00:00 00:00 00:00:15 1557 DISTUR NONE 00:00 00:00 00:00 00:10:00 1569 DISTUR NONE 00:00 00:00 00:00 00:00:15 1570 DISTUR NONE 00:00 00:00 00:00 00:00:15 1578 DISTUR NONE 00:00 00:00 00:00 00:03:00 1580 DISTUR NONE 00:00 00:00 00:00 00:00:15 1582 DISTUR NONE 00:00 00:00 00:00 00:00:15 1583 DISTUR NONE 00:00 00:00 00:00 00:01:00

Page 16: Descrption alarms - GSM NOKIA - 1000 à 1999

16 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

Disturbance printout parameters

1585 DISTUR NONE 00:00 00:00 00:00 00:05:00 1590 DISTUR NONE 00:00 00:00 00:00 00:00:15 1597 DISTUR NONE 00:00 00:00 00:00 00:00:15 1598 DISTUR NONE 00:00 00:00 00:00 00:00:15 1623 DISTUR NONE 00:00 00:00 00:00 00:02:00 1630 DISTUR NONE 00:00 00:00 00:00 00:00:15 1660 DISTUR NONE 00:00 00:00 00:00 00:00:15 1661 DISTUR NONE 00:00 00:00 00:00 00:00:15 1662 DISTUR NONE 00:00 00:00 00:00 00:00:15 1663 DISTUR NONE 00:00 00:00 00:00 00:00:15 1682 DISTUR NONE 00:00 00:00 00:00 00:00:15 1683 DISTUR NONE 00:00 00:00 00:00 00:00:15 1684 DISTUR NONE 00:00 00:00 00:00 00:10:10 1685 DISTUR NONE 00:00 00:00 00:00 00:00:15 1687 DISTUR NONE 00:00 00:00 00:00 00:01:15 1688 DISTUR NONE 00:00 00:00 00:00 00:00:15 1800 DISTUR NONE 00:00 00:00 00:00 00:00:15 1801 DISTUR NONE 00:00 00:00 00:00 00:00:15 1802 DISTUR NONE 00:00 00:00 00:00 00:00:15 1804 DISTUR NONE 00:00 00:00 00:00 00:00:15 1806 DISTUR NONE 00:00 00:00 00:00 00:00:15 1809 DISTUR NONE 00:00 00:00 00:00 00:00:15 1850 DISTUR NONE 00:00 00:00 00:00 00:05:00 1860 DISTUR NONE 00:00 00:00 00:00 00:01:15 1881 DISTUR NONE 00:00 00:00 00:00 00:01:30 1882 DISTUR NONE 00:00 00:00 00:00 00:00:15 1884 DISTUR NONE 00:00 00:00 00:00 00:00:15 1885 DISTUR NONE 00:00 00:00 00:00 00:01:05 1886 DISTUR NONE 00:00 00:00 00:00 00:00:15 1887 DISTUR NONE 00:00 00:00 00:00 00:00:15 1891 DISTUR NONE 00:00 00:00 00:00 00:00:15 1893 DISTUR NONE 00:00 00:00 00:00 00:00:15 1894 DISTUR NONE 00:00 00:00 00:00 00:03:00 1895 DISTUR NONE 00:00 00:00 00:00 00:01:30 1900 DISTUR NONE 00:00 00:00 00:00 00:00:15 1901 DISTUR NONE 00:00 00:00 00:00 00:00:15 1910 NOTICE NONE 00:00 00:00 00:00 00:00:15 1911 DISTUR NONE 00:00 00:00 00:00 00:00:15 1915 DISTUR NONE 00:00 00:00 00:00 00:00:15

Page 17: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 17

Disturbance Printouts (1000-1999) 1001 UNIT RESTARTED

Id:0900d805806a941aConfidential

3 1001 UNIT RESTARTEDMeaning

The unit has restarted.

Supplementary information fields1 working state of the unit

2 type of unit restart indicated by the initial loading program block (e.g. BOLERO):

FF cold restart 00 warm restart 01 hot restart 02 diagnostic restart

type of unit restart indicated by the state administration:

AA not defined

3 information on the unit restart:

00 spontaneous 01 executed by the user 02 executed by the recovery program block 03 executed by the recovery program block, the package identifier of the unit differs from that in the active maintenance computer 04 spontaneous repeated 05 executed with the service terminal command ZAU 06 the recovery program block has restarted the unit as a result of the alarm 1023 07 IWMANA has restarted the unit at the request of routine testing 08 the recovery program block has restarted the unit as a result of the alarm 1128 09 the recovery program block has restarted the unit in connection with a state change, because virtual loading was still in process in the unit

4 type of restart in the Working State and Configuration File (SCDFLE) when the unit is restarting:

00 warm restart 01 hot restart 55 mini restart

If the active maintenance computer (normally the OMU)

Page 18: Descrption alarms - GSM NOKIA - 1000 à 1999

18 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1001 UNIT RESTARTED

was restarted with the MML command USU and R=HOT was given as the restart type, the value of the field is 00. The type of restart was, however, a hot restart, if the value of supplementary information field 2 is 01 hot restart.

5 code loading type when the unit is restarting:

00 optimal loading 01 total loading 02 total loading from disk

If the active maintenance computer (normally the OMU) was restarted with the MML command USU and C=TOT or C=DISK was given as the code loading type, the value of the field is 01. Nevertheless, the loading was performed from disk.

6 file loading type when the unit is restarting:

00 unknown/not defined 01 virtual loading 02 immediate loading

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 19: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 19

Disturbance Printouts (1000-1999) 1002 RAM FAILURE

Id:0900d805806a941aConfidential

4 1002 RAM FAILUREMeaning

The RAM test program of the computer has observed a malfunctionin the RAM memory.

Supplementary information fields1 address of the faulty memory location 0...FFFFFFFF

InstructionsIf the alarm recurs, the CPU is probably faulty and needs to be replaced.The alarm supports the activation of the automatic recovery forthe object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 20: Descrption alarms - GSM NOKIA - 1000 à 1999

20 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1003 PARITY ERROR IN RAM

5 1003 PARITY ERROR IN RAMMeaning

Parity error in the RAM of the computer. The parity supervisioncircuit of the CPU has detected the error.

Supplementary information fields1 address of location where the RAM test was being carried out when the error was detected

InstructionsIf the alarm recurs, the CPU is probably faulty and needs to be replaced.The alarm supports the activation of the automatic recovery forthe object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 21: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 21

Disturbance Printouts (1000-1999) 1004 COMMUNICATION ERROR BETWEEN PRO-GRAM BLOCKS

Id:0900d805806a941aConfidential

6 1004 COMMUNICATION ERROR BETWEEN PROGRAM BLOCKSMeaning

The partner program block does not reply to the message sent to itwithin the specified time limit, or the received reply is erroneous.

Supplementary information fields1 error code 01 no reply 02 identification of reply is erroneous 03 status of reply is erroneous 04 sequence number of reply is erroneous

2 family identifier of program block setting the alarm

3 unit message bus address of the partner program block

4 family identifier of the partner program block

5 identifier of the message sent to the partner program block

6 subidentifier of the message sent to the partner program block

7 case-specific additional information

8 case-specific additional information

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 22: Descrption alarms - GSM NOKIA - 1000 à 1999

22 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1005 PLUG-IN UNIT RESTARTED

7 1005 PLUG-IN UNIT RESTARTEDMeaning

A plug-in unit has restarted.

Supplementary information fields1 type of plug-in unit See Diagnostics and Testing, Appendices

2 index of plug-in unit

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recovery forthe object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 23: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 23

Disturbance Printouts (1000-1999) 1007 RESTARTED PROGRAM BLOCK

Id:0900d805806a941aConfidential

8 1007 RESTARTED PROGRAM BLOCKMeaning

The program block has been restarted.

Supplementary information fields1 family identifier of the program block

2 error code 131d: program block was not found 132d: another program block of the same kind already exists 133d: program block deletion error 287d: program block has been deleted, or its creation failed 302d: program block has made a memory protection error 770d: program block did not answer the supervision message 771d: program block has acknowledged the supervision message with a wrong state, i.e the program block is in wrong state in relation to the working state of the unit 781d: state transition of the program block did not succeed

You can check its meaning in General Error Messages of System

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 24: Descrption alarms - GSM NOKIA - 1000 à 1999

24 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1008 MML PROGRAM RESTARTED

9 1008 MML PROGRAM RESTARTEDMeaning

The MMI Manager (MMIMAN) has restarted an MML program.

Supplementary information fields1 family identifier of the restarted MML program

InstructionsThe alarm requires no actions.The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 25: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 25

Disturbance Printouts (1000-1999) 1010 NO RESPONSE TO UNIT SUPERVISION MES-SAGE

Id:0900d805806a941aConfidential

10 1010 NO RESPONSE TO UNIT SUPERVISION MESSAGEMeaning

The unit has not responded in the allotted time to a supervisionmessage sent by the supervisory unit.

Supplementary information fields

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 26: Descrption alarms - GSM NOKIA - 1000 à 1999

26 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1012 EXCESSIVE RESTARTS OF UNIT

11 1012 EXCESSIVE RESTARTS OF UNITMeaning

The maximum number of restarts set for a unit has been exceeded.

Supplementary information fields

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 27: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 27

Disturbance Printouts (1000-1999) 1014 PROCESSOR LOAD RATE ALARM LIMIT EX-CEEDED

Id:0900d805806a941aConfidential

12 1014 PROCESSOR LOAD RATE ALARM LIMIT EXCEEDEDMeaning

The processor load rate exceeds the alarm limit defined for the unit atintervals of time defined for the unit. The alarm limit and the intervalare defined in BSPARA file.

Supplementary information fields1 processor load rate percentage

2 interval in hundredths of a second

InstructionsCheck the validity of the value set for the parameterCPU LOAD SUPERVISION LIMIT of BSPARA with the MML command:ZDOT:<unit type>;or find out the possible cause of overload.

This alarm may be given during the system reset because reset causesload. In those cases, no actions are required from the user.

To change processor load supervision limit, give the MML command:ZDOM:<unit type>:PROLL=<new supervision limit>;

CancellingNo cancelling.

Page 28: Descrption alarms - GSM NOKIA - 1000 à 1999

28 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1015 OPERATING SYSTEM ERROR COUNTER IN-CREASED

13 1015 OPERATING SYSTEM ERROR COUNTER INCREASEDMeaning

The alarm informs that the value of the error counter maintainedby the operating system has increased.

Supplementary information fields1 error code: identifies the fault that increased the counter thus causing the alarm. You can check its meaning in General Error Messages of System

2 program block that increased the counter

3 value of the counter, i.e. number of errors

InstructionsAscertain the reason for counter incrementation.

CancellingNo cancelling.

Page 29: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 29

Disturbance Printouts (1000-1999) 1016 MB INTERFACE FAILURE

Id:0900d805806a941aConfidential

14 1016 MB INTERFACE FAILUREMeaning

In the test, the message bus interface (MBIF) has been detectedfaulty. In the test, the unit sends a message to itself both on theactive and passive bus. It also checks the error counters of themessage buses, maintained by the operating system.

Supplementary information fields1 message bus test identifier:

1 message sending does not succeed despite several attempts 2 time supervision of message receiving has expired 3 received test message differs from the one sent 4 the transmission error counter of the MB has been incremented 5 the reception error counter of the MB has been incremented 6 time supervision of message sent with a group address has expired 7 time supervision of message sent with a pair address has expired 8 the supervision error counter of the MB has been incremented

2 message bus index

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recovery forthe object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 30: Descrption alarms - GSM NOKIA - 1000 à 1999

30 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1018 PROGRAM BLOCK COMMUNICATION ERROR

15 1018 PROGRAM BLOCK COMMUNICATION ERRORMeaning

The partner program block does not respond within thespecified time to the message sent to it, or the replyis faulty.

Supplementary information fields1 family identifier of program block giving the alarm

2 number of the message sent to the partner program block or number of the received message

3 error code 01 no reply 02 identification of reply is faulty 03 status of reply is faulty 04 sequence number of reply is faulty

4 number of missing reply messages

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 31: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 31

Disturbance Printouts (1000-1999) 1019 PROGRAM BLOCK ACTION FAILURE

Id:0900d805806a941aConfidential

16 1019 PROGRAM BLOCK ACTION FAILUREMeaning

Errors detected in the state administration procedures of aprogram block.

Supplementary information fields1 family identifier of program block

2 program block type in the family table of DXPARA 0 : normal program block <> 0 : program block is essential for unit functioning

3 error code of the recovery block 770d: program block did not answer the supervision message 771d: program block has acknowledged the supervision message with a wrong state. The program block is in wrong state in relation to the working state of the unit

You can check the meaning of other error codes in General Error Messages of System

InstructionsThe alarm requires no actions.The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supportingamount of the alarm with the MML command ARO.

CancellingNo cancelling.

Page 32: Descrption alarms - GSM NOKIA - 1000 à 1999

32 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1020 PROGRAM BLOCK START UP FAILURE

17 1020 PROGRAM BLOCK START UP FAILUREMeaning

When activating a program block an error has been detected whichoccurred either when creating or activating the program block.The fault may cause disturbances in the system, particularly if aprogram block creation error is in question.

Supplementary information fields1 family identifier of the detector of the error

2 the error code returned by the detector of the error, presented according to the general error code. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System

3 the message bus address of the unit where the error occurred

4 the family identification of the error-committing program block

InstructionsAdditional information: Printouts of Starting Phases.

Check the meaning of the DX error code.

If the error code is: 770d: The program block has failed to respond within the time limit to the activation message sent by the unit state administration program block (USAPRO). Possible causes are: - The program block has made a memory protection error. Check the log with the service terminal command ZSL. Check the program block's check sum, service terminal command ZSS. Check the program block's version, service terminal command ZSXP. - The initialisation time allotted to the program block is too short. Check whether the program block acknowledges USAPRO at all. Service terminal command ZOQ. - The program block has detected an error in its initialisation. Check the error log with the service terminal command ZGD.

771d: The program block has acknowledged negatively the activation message sent by USAPRO. Possible causes are: - The program block has detected an error in its

Page 33: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 33

Disturbance Printouts (1000-1999) 1020 PROGRAM BLOCK START UP FAILURE

Id:0900d805806a941aConfidential

initialisation. Check the version of the program block. Check the error log with the service terminal command ZGD. - The program block has been activated into a wrong state with regard to the unit's operating state. Check the supervision messages between the program block and USAPRO (message numbers 0001 and 0002). If the program block is constantly in a wrong state, USAPRO restarts the program block. See the RESTARTED PROGRAM BLOCK alarms, if any (alarm number 1007).

819d: The starting up of a library manager has failed. Possible causes are: - A fault in the initialisation of one of the libraries that the manager is responsible for. Check the versions of the manager and the library, service terminal commands ZSXP and ZSK. Check the error log with the service terminal command ZGD. - In the starting up of the library manager itself. Check the previous sections (770d, 771d).

All other error codes indicate a program block creation error.Probable causes are: a fault in the DXPARA family table, a faultyloading module, a discrepancy between the parameters of the familytable and the loading module, a storage area sufficiently large andfree cannot be found.

CancellingNo cancelling.

Page 34: Descrption alarms - GSM NOKIA - 1000 à 1999

34 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1021 PROGRAM BLOCK REWARMING STARTED

18 1021 PROGRAM BLOCK REWARMING STARTEDMeaning

The warming of the program block has been restarted. The rewarmingmay have been caused by one of the following: the thermometer (THERMO)has detected synchronization errors in the program block, the programblock has been reactivated, or its warming failed on the previousoccasion.

Supplementary information fields1 family identifier of the detector of the error USAPRO (A0): the detector of the error is the state supervision THERMO (16B): the detector of the error is the thermometer If THERMO is the detector, a program block synchronization error is in question.

2 identifier of the family to be warmed

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 35: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 35

Disturbance Printouts (1000-1999) 1022 PROGRAM BLOCK WARMUP FAILURE

Id:0900d805806a941aConfidential

19 1022 PROGRAM BLOCK WARMUP FAILUREMeaning

The warming up of a program block has failed. The program block hasnot acknowledged the warmup command sent by the unit stateadministration program block (USAPRO), or has acknowledged itnegatively. The fault can lie in either the active or the spare unit.The warming-up manager (WUPMAN) can also be the detector of the fault.

Supplementary information fields1 family identifier of the detector of the error USAPRO (A0): the detector is the state administration WUPMAN (108): the detector is the warming-up manager

2 error code returned by the detector of the error. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System

3 message bus address of the unit where the error occurred

4 family identifier of the program block that made the error

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 36: Descrption alarms - GSM NOKIA - 1000 à 1999

36 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1023 EXCESSIVE DISTURBANCES IN SUPERVI-SION

20 1023 EXCESSIVE DISTURBANCES IN SUPERVISIONMeaning

The unit state administration program block (USAPRO) has detected aserious error when supervising the functioning of the program blocksof the unit. The alarm may have been caused by one of the following:several program blocks have been restarted; or some critical programblock does not respond to the supervision, or refuses to respond to astate transition command.

In addition, the alarm may result from repeated rewarmings ofprogram blocks or from synchronisation errors. The situationleads to a restart of the unit.

Supplementary information fields1 type of error 00: error in program block supervision 01: error in the warmup or synchronisation of program blocks

2 family identifier of the detector of the error. USAPRO (A0): detector is state administration THERMO (16B): detector is the thermometer. If THERMO is the detector, a synchronisation fault of a critical program block is in question

error code returned by the detector of the error, presented according to the general error code 65535d: no significance You can check the meaning of error codes with a command of the service terminal extension MRS or in General Error Messages of System

message bus address of the unit where the error occurred FFFF: no significance family identifier of the program block that made the error FFFF: no significance

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 37: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 37

Disturbance Printouts (1000-1999) 1024 HAND PROCESS ERROR IN PROGRAMBLOCK

Id:0900d805806a941aConfidential

21 1024 HAND PROCESS ERROR IN PROGRAM BLOCKMeaning

The requested service could not be carried out due to thefailure of process family resource (hands) management.

Supplementary information fields1 ID of the system library service primitive that returned the error code. The field may have the following values:

0: creation of hands 1: creation of additional hands 2: reservation of hand 3: renewal of hand reservation 4: expiry of hand reservation 5: restart of hand 6: deletion of hand group

2 error code returned by system library service primitive. See General Error Messages of System for error code explanations

3 type of reserved hand/hand to be reserved. 0 if not known

4 number of reserved hand/hand to be reserved

5 life focus of the hand

6 computer address of the customer

7 family ID of the customer

8 process ID of the customer

9 life focus of the customer

InstructionsReservation of a hand fails typically in situation where allavailable hands have already been reserved (e.g. overloadsituations). If the fault situation (supplementary field 1value = 02) occurs only occasionally, the disturbance requiresno actions from the user.

In other cases, fill in a Problem Report and send it to yourlocal Nokia Siemens Networks representative. Enclose theprintouts obtained with the service terminal commands ZSCFE,ZGSC, ZSL, and with the F, D, H, and G commands of the FAM family

Page 38: Descrption alarms - GSM NOKIA - 1000 à 1999

38 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1024 HAND PROCESS ERROR IN PROGRAM BLOCK

extension.

CancellingNo cancelling.

Page 39: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 39

Disturbance Printouts (1000-1999) 1028 RESTARTED PROGRAM BLOCK IN PREPRO-CESSOR UNIT

Id:0900d805806a941aConfidential

22 1028 RESTARTED PROGRAM BLOCK IN PREPROCESSOR UNITMeaning

A program block has been restarted.

Supplementary information fields1 plug-in unit index:

.. : control plug-in unit other values: line terminal plug-in unit

2 program block ID

3 error code:

770d : program block has not responded to supervision message 771d : program block has acknowledged supervision message with wrong state, i.e. the program block is in the wrong state in relation to the unit's working state 781d : failure in changing state of program block 287d : program block has been deleted, or its creation has failed 302d : memory protection error by program block 131d : program block not found 132d : an identical program block already exists 133d : error in deleting program block

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 40: Descrption alarms - GSM NOKIA - 1000 à 1999

40 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1029 SCCP STP MESSAGE PREVENTION

23 1029 SCCP STP MESSAGE PREVENTIONMeaning

SCCP has detected at the signalling transfer point a signalling messagewhose transit is wanted to be prevented or of which an alarm needs to beissued.

If the transit message is destroyed, it may cause disturbancein the function of the user parts of the signalling point that sentthe message. Usage restrictions for transit messages are usually seton exchanges that function on another operator's interface.

Supplementary information fields1 type of access right violation of the STP function (cause code)

01 the source point in question should not send signalling messages to the destination point (the message has been transmitted) 02 the source point in question is not allowed to send signalling messages to the destination point (the message has been destroyed or sent back) 03 the incoming link set in question should not be used to send signalling messages to the destination point (the message has been transmitted) 04 the incoming link set in question is not to be used to send signalling messages to the destination point (the message has been destroyed or sent back) 05 the pointer of the global title in the calling party address global title is not permitted (the message has been destroyed or sent back) 06 no analysis can be found for the root of the calling party address global title (the message has been destroyed or sent back)

2 destination point signalling network, which can get the following values:

00 international network 0, IN0 04 international network 1, IN1 08 national network 0, NA0 0C national network 1, NA1

3 destination point code value of the processed signalling message

4 originating point signalling network, which can get the following values:

00 international network 0, IN0 04 international network 1, IN1

Page 41: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 41

Disturbance Printouts (1000-1999) 1029 SCCP STP MESSAGE PREVENTION

Id:0900d805806a941aConfidential

08 national network 0, NA0 0C national network 1, NA1

5 originating point code value of the processed signalling message

6-10 if Supplementary information field 1 has the value 01, 02, 03 or 04, the value (5 sequential bytes) indicates the signalling point code of the signalling point and the signalling network, from which the signalling message was received. The field is coded so that the first byte indicates the signalling network and the next four indicate the signalling point code. E.g. the signalling point 260 of the NA0 network would be coded as follows: 08 00 00 02 60

If Supplementary information field 1 has the value 05 or 06, the value indicates the root parameter values of the calling party address global title in the following order: - the standard of the global title - global title indicator (GTI) - translation type (TT) - numbering plan + encoding type (NP+ENC) - nature of address indicator (NAI)

If a field has the value FF, the root parameter in question is not defined on the value of that global title indicator (GTI)

InstructionsProcedures on the basis of the value of Supplementary informationfield 1 (cause code):

Cause codes 01 and 02:

SCCP screening information says that messages originating from thesignalling point mentioned in Supplementary information field 5should not be transferred to the destination point. Check if thisrestriction is justified and remove the blocking with the MMLcommand ODM if necessary. In other case the operator who owns thesignalling point mentioned in Supplementary information fields 4and 5 should be notified about an access right violation.

Cause codes 03 and 04:

SCCP screening information says that messages originating fromthe signalling network and the adjacent signalling point (channelsystem) mentioned in Supplementary information field 6 should notbe transferred to the destination point. Check if this restrictionis justified and remove the blocking with the MML command ODM, ifnecessary. In other case the operator who owns the adjacentsignalling point mentioned in Supplementary information field 6

Page 42: Descrption alarms - GSM NOKIA - 1000 à 1999

42 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1029 SCCP STP MESSAGE PREVENTION

should be notified about an access right violation.

Cause code 05:

The calling party address of the received SCCP STP message uses aglobal title indicator value that is prohibited in the parameterset of the destination point mentioned in Supplementary informationfields 2 and 3. Check if this restriction is justified and removethe restriction with the MML command OCM, if necessary. In othercase the operator who owns the signalling point mentioned inSupplementary information fields 4 and 5 should be notified aboutan access right violation.

Cause code 06:

The calling party address of the received SCCP STP message usesa global title with root parameters that do not have a matchinganalysis in the SCCP analysis information. Check if the rootparameters need to be analysed and remove the analysis with theMML command OCM, if necessary. If the root parameters need to beanalysed, check if there should exist an analysis for the globaltitle in question, and create it with the MML command NBC, ifnecessary. In other case the operator who owns the signallingpoint mentioned in Supplementary information fields 4 and 5 shouldbe notified about an access right violation.

CancellingNo cancelling.

Page 43: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 43

Disturbance Printouts (1000-1999) 1033 OSI CLNS CONFIGURATION FAILED

Id:0900d805806a941aConfidential

24 1033 OSI CLNS CONFIGURATION FAILEDMeaning

The configuration of the connectionless OSI network service (CLNS)has failed. This can be caused by either the time-out of the timerthat controls the approval of the configuration, or errors in theconfiguration data. After a configuration failure, the system usesthe default value attributes for connectionless network services.

Supplementary information fields1 the name of the CLNS used in the configuration

2 the type of the disturbance observation 0 type data is not available 1 time-out of the timer 2 an error during the configuration phase 3 an error during the attribute setting phase

3 a general error code which tells why the configuration of the CLNS of the OSI failed. You can check its meaning in General Error Messages of System

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 44: Descrption alarms - GSM NOKIA - 1000 à 1999

44 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1034 MAXIMUM SEQUENCE NUMBER OF OSI CLNS EXCEEDED

25 1034 MAXIMUM SEQUENCE NUMBER OF OSI CLNS EXCEEDEDMeaning

The number of a connectionless OSI network service (CLNS) has exceededthe maximum value. This is probably due to a malfunction in the OSInetwork IS routing equipment. Connectionless network service can notbe used for 20 minutes, during which time it is not possible totransfer routing data or user data. This is to ensure that theclearing of the number does not cause disturbances in other nodes,but it is possible that there will be some interruptions in the OSIservices.

Supplementary information fields

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 45: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 45

Disturbance Printouts (1000-1999) 1035 UPU MESSAGE RECEIVED

Id:0900d805806a941aConfidential

26 1035 UPU MESSAGE RECEIVEDMeaning

The exchange has received a User Part Unavailable message (UPU).This message informs the sending end of a signalling message thatthe user part of the destination address is not available.Depending on the unavailable user part (TUP and ISUP) the telephonetraffic and signalling traffic fail. In the case of SCCP, usedservices fail.

Supplementary information fields1 network from which the UPU message came:

network code network ------------ ------ 00 national network 0 04 national network 1 08 international network 0 0C international network 1

2 header code of message

3 destination point code received in message, indicating the destination point of the unavailable user part

4 user part identifier received in the user_part_info of the message, indicating the unavailable user part in the destination point (3rd supplementary information, DPC)

identifier user part ---------- --------- 00 spare 01 spare 02 spare 03 SCCP 04 TUP 05 ISUP 06 DUP 07 ) spare ... ) spare 0F MTP test user part

5 reason for the unavailability of the user part (4th supplementary information), obtained from the user_part_info of the message

Page 46: Descrption alarms - GSM NOKIA - 1000 à 1999

46 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1035 UPU MESSAGE RECEIVED

code reason for unavailability ---- ------------------------- 00 user part unknown in the DPC 01 user part has not been created, or no service has been created for it 02 user part cannot be reached in the DPC

InstructionsIf the message traffic of the user part concerned should be possibleto the destination point, check from the operator of the destinationpoint whether the user part has been created and whether it isavailable.

CancellingNo cancelling.

Page 47: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 47

Disturbance Printouts (1000-1999) 1044 ERROR IN SWITCH COMPARE TEST

Id:0900d805806a941aConfidential

27 1044 ERROR IN SWITCH COMPARE TESTMeaning

The comparison test of the switching network has observed an error.The comparison test compares the incoming bit patterns withthe outgoing bit patterns in the connections of the switching network.

The problem can be caused by- defective cabling- faulty power supply of the exchange- faulty plug-in unit of the switching network (SWSPS, SWCSM)- faulty control processor of switching network (SWCOP)

Supplementary information fields1 PCM line of the outgoing circuit

2 time slot of the outgoing circuit

3 PCM line of the incoming circuit

4 time slot of the incoming circuit

5 incoming bit pattern

6 outgoing bit pattern

InstructionsThe alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount ofthe alarm with the MML command ARO.

To determine what has caused the alarm, proceed inthe following way:

1. Run the diagnosis for the unit that is the object unit of the alarm. Bring the unit in the test state (TE) using the USC command and run the diagnosis using the UDU command. If the diagnosis cannot locate the fault, proceed to the next step.

2. Check the cabling. Check the physical connections of the SWCSM, SWCOP, SWSPS plug-in units. Check that the cables are correctly in place and that correct cable type has been used. If the problem is not in the cabling, proceed to the next step.

3. Replace the SWSPS plug-in unit. See Instructions for Replacing Plug-in Units. If replacing the plug-in unit does not help, proceed to the next step.

Page 48: Descrption alarms - GSM NOKIA - 1000 à 1999

48 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1044 ERROR IN SWITCH COMPARE TEST

4. Replace the SWCOP plug-in unit. See Instructions for Replacing Plug-in Units. If replacing the plug-in unit does not help, proceed to the next step.

5. The cause of the alarm can be external disturbances conducted trough power supply. In this case the problem can be solved only by removing the source of the disturbances.

CancellingNo cancelling.

Page 49: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 49

Disturbance Printouts (1000-1999) 1045 ERROR BETWEEN MARKER TABLES ANDSWITCH CONTROL MEMORY

Id:0900d805806a941aConfidential

28 1045 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORYMeaning

This alarm indicates a temporary defect in the switch controlmemory. There is a difference between the data of the switchcontrol memory and the data of the switching file.

The problem can be caused by- defective cabling- faulty power supply of the exchange- faulty plug-in unit of the switching network (SWCSM)- faulty control processor of switching network (SWCOP)

Supplementary information fields1 PCM line of the outgoing circuit

2 time slot of the outgoing circuit

3 PCM line of the incoming circuit in the control memory

4 time slot of the incoming circuit in the control memory

5 PCM line of the incoming circuit in the reserve table

6 time slot of the incoming circuit in the reserve table

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

To determine what has caused the alarm, proceed inthe following way:

1. Run the diagnosis for the unit that is the object unit of the alarm. Bring the unit in the test state (TE) using the USC command and run the diagnosis using the UDU command. If the diagnosis cannot locate the fault, proceed to the next step.

2. Check the cabling. Check the physical connections of the SWCSM, SWCOP plug-in units. Check that the cables are correctly in place and that correct cable type has been used. If the problem is not in the cabling, proceed to the next step.

3. Replace the SWCSM plug-in unit. See Instructions for Replacing

Page 50: Descrption alarms - GSM NOKIA - 1000 à 1999

50 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1045 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORY

Plug-in Units. If replacing the plug-in unit does not help, proceed to the next step.

4. Replace the SWCOP plug-in unit. See Instructions for Replacing Plug-in Units. If replacing the plug-in unit does not help, proceed to the next step.

5. The cause of the alarm can be external disturbances conducted trough power supply. In this case the problem can be solved only by removing the source of the disturbances.

CancellingNo cancelling.

Page 51: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 51

Disturbance Printouts (1000-1999) 1047 NO RESPONSE FROM CONTROLLER OFSWITCHING NETWORK

Id:0900d805806a941aConfidential

29 1047 NO RESPONSE FROM CONTROLLER OF SWITCHING NETWORKMeaning

The switch control processor (SWPRO or SWCOP) has not acknowledged thesupervision message sent by the supervising unit within the specifiedtime limit.

Supplementary information fields1 type of the controller of GSW. received.

2 index of the controller of GSW.

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 52: Descrption alarms - GSM NOKIA - 1000 à 1999

52 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1048 CONTROLLER OF SWITCHING NETWORK RE-STARTED

30 1048 CONTROLLER OF SWITCHING NETWORK RESTARTEDMeaning

The alarm informs of an erroneous switch control processor (SWCOP orSWPRO) restart.

Supplementary information fields1 type of the controller of GSW restarted

2 index of the controller of GSW

InstructionsThe alarm requires no actions. The alarm supports the activation ofthe automatic recovery for the object unit. You can check the supportingamount of the alarm with the MML command ARO.

CancellingNo cancelling.

Page 53: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 53

Disturbance Printouts (1000-1999) 1049 SEMIPERMANENT MULTICHANNEL CONNEC-TION MISSING

Id:0900d805806a941aConfidential

31 1049 SEMIPERMANENT MULTICHANNEL CONNECTION MISSINGMeaning

The switching data of a semipermanent multichannel connection iserroneous. The data in the files (SMWIBA/SMMUPO - HNCONN/LICONF) isinconsistent.

Supplementary information fields1 type of connection (point-to-point connection PTP/point-to-multipoint connection PTM)

00 multichannel connection between two external PCM circuits 01 multichannel multipoint connection between external PCM circuits

2 the connection's incoming PCM circuit, from SMWIBA/SMMUPO

3 the connection's incoming time slot, from SMWIBA/SMMUPO

4 the incorrect information, in the HNCONN/LICONF files, of the connection's incoming PCM circuit

5 the incorrect information, in the HNCONN/LICONF files, of the connection's incoming time slot

6 the connection's outgoing PCM circuit

7 the connection's outgoing time slot

8 error code:

01 connection is missing from HNCONN 02 connection is missing from LICONF

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 54: Descrption alarms - GSM NOKIA - 1000 à 1999

54 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1055 TCAP TRANSACTION FAILURE

32 1055 TCAP TRANSACTION FAILUREMeaning

The Transaction Capabilities Application Part (TCAP)of the common channel signalling system has detected an errorin the management of a transaction. The transaction has beeninterrupted due to this error.The disturbance has no effect on other transactions.

Supplementary information fields1 type of the error. It can have the following values:

01 beginning the transaction has failed in the user's end, TCAP has not located the SCCP computer unit 02 beginning the transaction has failed in the network because the TCAP user has not stated the version of TCAP to be used 03 beginning of the transaction has failed in the network for unknown reasons 04 transaction has ended abnormally with the hand's time-out 05 transaction has ended abnormally for unknown reasons 06 sending a message to the user has failed 07 sending a message to the SCCP has failed 08 operation automatons have been used up

2 computer address of the party that requested the service

3 family identifier of the party that requested the service

4 process identifier of the party that requested the service

5 life focus of the party that requested the service

6 reference number in the DX log. The log contains additional information on the error. If the reference number is not used in the log, the value of the field is zero

InstructionsIf the error in the first supplementary information fieldis a type 4 error, and the alarm is given occasionally,the alarm requires no actions.

In other cases, fill in a Problem Report and send it toyour local Nokia Siemens Networks representative. Include theprintouts obtained during the error situation from the messagemonitoring process family 114 (TCAP), and with the serviceterminal commands ZSCFE, ZGSC and ZSL as well as the FAM

Page 55: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 55

Disturbance Printouts (1000-1999) 1055 TCAP TRANSACTION FAILURE

Id:0900d805806a941aConfidential

family extension commands F, D, H and G.

CancellingNo cancelling.

Page 56: Descrption alarms - GSM NOKIA - 1000 à 1999

56 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1056 MESSAGE FROM NETWORK TO UNKNOWN SUBSYSTEM

33 1056 MESSAGE FROM NETWORK TO UNKNOWN SUBSYSTEMMeaning

SCCP has received a message from the network. The message'sdestination is an unknown subsystem.

Supplementary information fields1 type of the SCCP message that has an unknown subsystem as its destination. It can have the following values:

01 CR Connection Request 02 CC Connection Confirm 03 CREF Connection Refused 04 RLSD Released 05 RLC Release Complete 06 DT1 Data Form 1 07 DT2 Data Form 2 08 AK Data Acknowledgement 09 UDT Unitdata 0A UDTS Unitdata Service 0B ED Expedited Data 0C EA Expedited Data Acknowledgement 0D RSR Reset Request 0E RSC Reset Confirm 0F ERR Protocol Data Unit Error 10 IT Inactivity Test 11 XUDT Extended Unitdata 12 XUDTS Extended Unitdata Service 13 LUDT Long Unitdata 14 LUDTS Long Unitdata Service

2 network indicator. It can have the following values:

00 international network 0 04 international network 1 08 national network 0 0C national network 1

3 destination point code

4 number of the destination subsystem unknown to SCCP. If the message that is to be routed does not contain a subsystem number, the field's value is FF

5 originating point code

6 number of the originating subsystem. If the message that is to be routed does not contain a subsystem number, the field's

Page 57: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 57

Disturbance Printouts (1000-1999) 1056 MESSAGE FROM NETWORK TO UNKNOWNSUBSYSTEM

Id:0900d805806a941aConfidential

value is FF

7 reference number in the DX log. The log contains the incorrect message. If the reference number is not used in the log, the field's value is 0

InstructionsIf the error occurs repeatedly, do the following:

If the value of Supplementary information field 4 is something otherthan FF, check if the subsystem given in Supplementary informationfield 4 has been created in the relevant signalling point of thesignalling network by using the signalling point's SCCP Data HandlingMML commands. The signalling point is given Supplementary informationfield 3 and the signalling network in Supplementary information field2.

If the subsystem has not been created, check if it should be createdin the system and, if necessary, create it with the MML commands ofthe previously mentioned command group.

If the subsystem does not belong in the system, contact the networkoperator of the signalling point mentioned in Supplementary informationfield 5 to find out why they are trying to send messages to thesubsystem mentioned Supplementary information field 4.

If the value of Supplementary information field 4 is FF, the subsystemnumber is missing from the destination data of the received message inSupplementary information field 5 signalling point. The subsystem numbercannot be obtained through global title translation.

In other cases, fill in a Problem report and send it to your localNokia Siemens Networks representative. Include the printouts ofservice terminal commands ZSCFE, ZGSC and ZSL in the report.

CancellingNo cancelling.

Page 58: Descrption alarms - GSM NOKIA - 1000 à 1999

58 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1058 ERROR IN SMUX PLUG-IN UNIT

34 1058 ERROR IN SMUX PLUG-IN UNITMeaning

The SMUX plug-in unit test has detected a fault in the plug-inunit. The test is to check that the SMUX plug-in unit multiplexesthe 16 kbit/s channels correctly to the 64 kbit/s channel.

The test is carried out in the switching network by branchingtime slots, coming to and leaving from the SMUX, to the SWCOP,and by checking that the bit pattern contained in the time slots iscorrect.

Supplementary information fields1 index of SMUX plug-in unit

2 PCM circuit coming to SMUX plug-in unit

3 incoming time slot

4 PCM circuit outgoing from SMUX plug-in unit

5 outgoing time slot

6-9 four consecutive samples of bit patterns coming to SMUX plug-in unit.

10-13four consecutive samples of bit patterns departing from SMUX plug-in unit.

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 59: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 59

Disturbance Printouts (1000-1999) 1061 ERROR IN SWITCH COMPARE TEST

Id:0900d805806a941aConfidential

35 1061 ERROR IN SWITCH COMPARE TESTMeaning

The comparing test of the switching network (GSWB) has detected anerror. The comparing test compares the bit pattern created in theswitching network by the switchings in the network to thebit pattern leaving the switching network.

Supplementary information fields1 outgoing PCM circuit (corresponds to a 4 Mbit/s circuit group)

2 outgoing PCM circuit's 8 kbit/s channel

3 incoming PCM circuit (corresponds to a 4 Mbit/s circuit group)

4 incoming PCM circuit's 8 kbit/s channel

5 incoming bit pattern

6 outgoing bit pattern

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 60: Descrption alarms - GSM NOKIA - 1000 à 1999

60 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1062 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORY

36 1062 ERROR BETWEEN MARKER TABLES AND SWITCH CONTROL MEMORYMeaning

The switching data of the switching network control memory and theincoming connections file is different.

Supplementary information fields1 outgoing PCM circuit (corresponds to a 4 Mbit/s circuit group)

2 outgoing PCM circuit's 8 kbit/s channel

3 incoming PCM circuit in the control memory

4 incoming PCM circuit channel in the control memory

5 incoming PCM circuit in the incoming connections file

6 incoming PCM circuit channel in the incoming connections file

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 61: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 61

Disturbance Printouts (1000-1999) 1064 UNIT UPDATE FAILURE

Id:0900d805806a941aConfidential

37 1064 UNIT UPDATE FAILUREMeaning

Failure in the updating of the partner unit or another unit to beupdated (M, SSU). The file has not been updated in the unit whichreceived the updating input, either.

Supplementary information fields1 family identifier of the program block that detected the failure

2 number of the message which caused the updating

3 unit to be updated

4 error code returned by the unit to be updated 16d REQMAN does not reply to the disk update inquiry before time-out 106d file error

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of thealarm with the MML command ARO.

CancellingNo cancelling.

Page 62: Descrption alarms - GSM NOKIA - 1000 à 1999

62 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1065 DISK UPDATE FAILURE

38 1065 DISK UPDATE FAILUREMeaning

A file modification made in the Central Memory has not beenupdated onto disk. The data of the file on the disk does notcorrespond to the data in the Central Memory.

Supplementary information fields1 number of the message that caused the updating

2 error code returned by the file update (general error message of the system). See General Error Messages of System for error code explanations

3 file number

4 offset from the beginning of the file

Instructions1. Check the alarms set by the File Updating Request Manager Program Block (REQMAN).

2. Move the file shown in the additional information field 3 from the Central Memory to disk with the MML command DFC.

If moving the file to the disk fails, it is possible thatthe operation of the switch suffers disturbances after thenext disk loading in so far as the operation has to do withthe file in question.

CancellingNo cancelling.

Page 63: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 63

Disturbance Printouts (1000-1999) 1070 CCS7 PROGRAM BLOCK DATA ERROR

Id:0900d805806a941aConfidential

39 1070 CCS7 PROGRAM BLOCK DATA ERRORMeaning

A program block of the common channel signalling system has detectedan error in the working file of the MTP routing.

Supplementary information fields1 error code 01 value of data exceeds the accepted range 02 record data are in conflict 03 value of stored data is in conflict with new value received for that data

2 file number

3 record number

4 subrecord number

InstructionsIn N+1 protected units the warming up of the files may havealready corrected the error detected. If the fault situationis over, futher actions are not needed.

Examine the other alarms given by the unit using the MML command AHO.If necessary, examine also the alarm history of the unit using theMML command AHP. If the alarm occurs repeatedly, the files of theCCS7 level 3 are likely to contain an error.

If the alarm still continues to occur, save the defective fileon disk for later examination for errors and contact the customersupport service. Check also the log print-outs of the unit.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 64: Descrption alarms - GSM NOKIA - 1000 à 1999

64 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1071 PROCESSOR TIME SHORTAGE

40 1071 PROCESSOR TIME SHORTAGEMeaning

There is not enough processor time for all processes fit for running.The operating system kernel has temporarily increased the priority ofthose processes that have not received running time for some time.The processor has a 100 utilization rate.

The situation results from a computer overload or a fault in someprocesses.

Supplementary information fields1 id number of the processor whose load was disturbingly high

2 number of processes whose priority was increased by the operating system during the last inspection of the queue for processes fit for running

3 the identifier of the family that preceded the process with highest priority among the processes whose priority was increased in the queue for processes fit for running. Fields 2 and 3 contain the identifier of the family in full

4 process identifier, see description in field 2

5 priority of the process identified in fields 2 and 3

6 identifier of a family that was fit for running during the whole of the inspection period, although it received processor time during the period. If the disturbance occurred because of a looped process, this process is the probable cause of the disturbance.

Fields 5 and 6 contain the family identifier in full.

If there is no such process in the queue for processes fit for running, the identifier is FFFF FFFF

7 process identifier, see description in field 5

8 priority of the process identified in fields 5 and 6. If there is no such process (that is the process identifier is FFFF FFFF) the value is 0

InstructionsThe disturbance may result from a computer overload. Check if thereis an overload in the network element or a local overload in somecomputer unit of the network element.

Page 65: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 65

Disturbance Printouts (1000-1999) 1071 PROCESSOR TIME SHORTAGE

Id:0900d805806a941aConfidential

If the fault lies elsewhere, the maintenance of the exchange startsactions to correct the fault situation. In this case it is alsorecommended to inform the supplier of the software package onthe fault so that they can investigate the reason for the fault.

CancellingNo cancelling.

Page 66: Descrption alarms - GSM NOKIA - 1000 à 1999

66 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1072 SIGNALLING LINK OUT OF SERVICE

41 1072 SIGNALLING LINK OUT OF SERVICEMeaning

A signalling link has failed and changed state from IN SERVICE toOUT OF SERVICE, or its initial alignment attempt has failed. If thissignalling link is the only one in the signalling link set, the systemsets also alarm 2070, LINK SET UNAVAILABLE. If there is an alternativesignalling link available in the link set, the system performs achangeover. In this case the signal transmission capacity is alsodecreased.

Supplementary information fields1 signalling link number

2 signalling link error code

01 stop command received 02 erroneous BSN received repeatedly 03 erroneous FIB received repeatedly 04 error ratio too high 05 acknowledgement delay too long 06 initial alignment unsuccessful 07 congestion too long 08 SIO received when one is not expected 09 SIN received when one is not expected 0A SIE received when one is not expected 0B SIOS received when one is not expected 0C SIPO received when one is not expected 0D SIB received when one is not expected

3 number of the signalling link terminal

4 number of the logical signalling link terminal

5 number of the internal PCM circuit

6 number of the external PCM circuit

7 previous working state of signalling link terminal:

00 IDLE 01 OUT OF SERVICE 02 MONITORING 03 WAIT FOR FISU 04 NOT ALIGNED 05 ALIGNED 06 PROVING 07 LOOP CHECK 08 ALIGNED/NOT READY

Page 67: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 67

Disturbance Printouts (1000-1999) 1072 SIGNALLING LINK OUT OF SERVICE

Id:0900d805806a941aConfidential

09 ALIGNED/READY 0A IN SERVICE 0B EMPTYING 0C UPPER LEVEL OUTAGE 0D LOCAL PROCESSOR OUTAGE 0E REMOTE PROCESSOR OUTAGE 0F BOTH PROCESSORS OUTAGE 10 INTERNAL LOOP TEST 11 EXTERNAL LOOP TEST

InstructionsIf the value of 7th supplementary information is 0A (IN SERVICE).it means that the signalling link given in the 1st supplementaryinformation has failed and its state has changed from IN SERVICEto OUT OF SERVICE. The system automatically tries to reactivatethe signalling link.

1. If the value of the 2nd supplementary information is 04, check data transmission. This error code is typically given when there is a PCM cutoff. If the exchange terminal does not indicate PCM cutoff, the bit error ratio is too high for some other reason, or there are problems in synchronization. If the signalling link stays unavailable for a long time and does not realign automatically, monitor the link with a protocol analyzer in order to solve the problem.

2. If the value of the 2nd supplementary information is 0B, the remote signalling link terminal has for some reason detected the link faulty. If this happens repeatedly, ask the remote end operator what is the reason for this. If the alarm is caused by a PCM circuit with a high bit error ratio, the link typically gives error codes 04 and 0B alternatingly, depending on which end first detects the error ratio.

3. If the value of the 2nd supplementary information is 02, 03, 05, 08, 09, 0A, 0C or 0D, there is a problem in the operation of the remote end signalling link terminal. In these cases, no actions are required from the user. These fault situations are not common; if these error codes are often given in this alarm, monitor the link with a protocol analyzer to analyze the fault situation.

Check that the level 2 error correction method is the same in both ends of the signalling link: either the basic method or the preventive cyclic retransmission (PCR). You can check the error correction method with the MML command NOI: ZNOI:<parameter set number>; You can find out the parameter set number with the MML command NCI: ZNCI:<link number>;

Page 68: Descrption alarms - GSM NOKIA - 1000 à 1999

68 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1072 SIGNALLING LINK OUT OF SERVICE

4. The value 0E of the 2nd supplementary information is used only in ANSI network, and it means that the signalling link has been restarted as it has been congested for the period of T111 T31. If this happens repeatedly, there is serious overload in the signalling network, and increase the capacity or rerouting should be seriously considered.

5. If the value of the 2nd supplementary information is 01, the CCNETM has stopped the link. This can happen if, for example, the test procedure of the signalling link fails. The most common reason for this is that the signalling link code (SLC) is not same in both ends.

If the value of the 2nd supplementary information is 06, the link is out of service and realignment fails. In this case the value of the 7th supplementary information indicates the phase of the initial alignment procedure in which errors were detected. Usually the alignment fails because the bit error ratio is too high. Analyze the fault with a protocol analyzer.

6. Check that the signalling link bit rate is the same in both ends: either 64kbit/s or 56kbit/s. You can check the signalling link bit rate with the MML command NOI: ZNOI:<parameter set number>; You can find out the parameter set number with the MML command NCI: ZNCI:<link number>;

CancellingNo cancelling.

Page 69: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 69

Disturbance Printouts (1000-1999) 1076 FORCED LIGHTWEIGHT SCHEDULING

Id:0900d805806a941aConfidential

42 1076 FORCED LIGHTWEIGHT SCHEDULINGMeaning

A lightweight hand within a process family has been running fora period of time that exceeds the limit defined in the parameterfile. The other hands in the family have been waiting for theirturn to run. The running of the hand identified in the supplementaryinformation of the alarm is stopped and the next hand is allowed torun, so as not to disturb the functioning of the other hands in thefamily.

The situation usually results from a fault in the functioning ofa hand.

Supplementary information fields1 identifier of the family where forced scheduling was executed

2 process identifier of the hand whose running was stopped

3 focus of the process identifier of the hand whose running was stopped

4 length of the period, in seconds, that the hand was running

InstructionsThere is a temporary disturbance in the functioning of the family.Since the reason is usually a fault in the application, it isrecommended that you inform your local Nokia Siemens Networksrepresentative about the fault, in order to investigate the reasonfor the fault.

The alarm requires no other actions.

CancellingNo cancelling.

Page 70: Descrption alarms - GSM NOKIA - 1000 à 1999

70 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1077 FREE STACK SIZE BELOW LIMIT

43 1077 FREE STACK SIZE BELOW LIMITMeaning

The free stack size of the process mentioned in thesupplementary information of this alarm is below the thresholdof 128 bytes. If it continues, the situation may disturb thefunctioning of the computer.

Supplementary information fields1 family identifier of the process whose free stack size is below the limit. Fields 1, 2 and 3 consist of the complete identifier of the process in question

2 identifier of the process which set the disturbance, see description in field 1

3 focus of the process, see field 1

4 free stack size

5 decrease in free stack size was detected because:

1 ESP value was below the threshold 2 values other than zero were detected in the lowest 128 bytes of the stack

InstructionsThe alarm indicates a temporary disturbance in the functioningof the process. The disturbance may have been caused by an errorin the software or the packaging, so it is recommended that youinform your local Nokia Siemens Networks representative in orderto detect the possible fault.

CancellingNo cancelling.

Page 71: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 71

Disturbance Printouts (1000-1999) 1078 PROCESS EXCEPTION

Id:0900d805806a941aConfidential

44 1078 PROCESS EXCEPTIONMeaning

A process, specified in the supplementary information of thisalarm, has caused an exception and, as a result, the process hasbeen frozen. The exception may result from a software orhardware fault.

The recovery from the freezing of a process may requiremaintenance actions, for instance a process restart or acomputer switchover.

Supplementary information fields1 family identifier of the process that caused an exception

2 process identifier of the process that caused an exception

3 type of exception. Possible values are:

00 division by zero 04 overflow 05 segmentation fault 06 invalid operation code 07 parallel processor missing 08 double fault 09 faulty segment reference in parallel processor 0A invalid Task State Segment 0B segment not present 0C stack exception 0D general protection error 0E page fault 10 error in parallel processor FF exception not found in the log

4 selector of the exception address. If the value of field 3 is FF, this field has no significance

5 offset of the exception address. If the value of field 3 is FF, this field has no significance

InstructionsIf the computer has not set alarms on hardware fault,the reason for the exception is probably a fault in software.To correct the fault, contact your local Nokia Siemens Networksrepresentative.

Page 72: Descrption alarms - GSM NOKIA - 1000 à 1999

72 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1078 PROCESS EXCEPTION

The alarm requires no further actions.

CancellingNo cancelling.

Page 73: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 73

Disturbance Printouts (1000-1999) 1080 PROCESS STOPPED

Id:0900d805806a941aConfidential

45 1080 PROCESS STOPPEDMeaning

A process, defined in the supplementary information fields of thisalarm, is in a situation where it is impossible to continueexecution. The process is stopped on purpose. The fault situationis usually a result of erroneous packaging or functioning.

Stopping the process may require maintenance, for example, aprocess restart.

Supplementary information fields1 family identifier of the process that was stopped

2 process identifier of the process that was stopped

3 the fault was noticed by:

01 LIBGEN library 02 code produced by the TNSDL translator 03 Launcher (i.e. the Program starter and supervisor in Linux computer units)

4 cause of the failure. Values set by system program library:

01 master calling for stopping 02 FAMILY_SERVICES_IN_USE attribute missing 03 error in buffered message reception 04 incorrect family generation 05 no more LDT slots 06 saving the message failed 07 numbers of hand types not valid 08 hand initialization failed 09 incorrect user for the routine lib_TNSDL_stop_r 0A incorrect user for the routine lib_TNSDL_create_r 0B incorrect user for the routine lib_receive_msg_r 0C parameter error, MIN_FREE_TIME 0D parameter error, START_PTR 0E parameter error, TRANSITION_PTR 0F internal error in reserving data area for lightweight hand 10 internal error in saving the stack

Values set by Launcher:

20 no response to supervision messages

Values set by the TNSDL translator:

80 master called for STOP statement

Page 74: Descrption alarms - GSM NOKIA - 1000 à 1999

74 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1080 PROCESS STOPPED

81 overflow in user's encode routine 82 overflow in system's encode routine 83 error in user's decode routine, FPAR of hand 84 error in user's decode routine, internal INPUT 85 internal message queue full 86 internal message queue empty 87 error in user's decode routine 88 message too short 89 table indexed beyond the index area

5 additional information on the fault. The field is only in use if field 4 has one of the below-mentioned values. The meaning of the field is also explained below.

01 lower word of the return address offset 81 number of message being handled at the time of the error 82 number of message being handled at the time of the error 87 number of message being handled at the time of the error 88 number of message being handled at the time of the error 89 identifier of the source code file where the erroneous reference is made (internal identifier of the translator)

6 additional information on the fault. The field is only in use if field 4 has one of the below-mentioned values. The meaning of the field is also explained below.

01 upper word of the return address offset 89 row number of the source code file where the erroneous reference is made

7 additional information on the fault. The field is only in use if field 4 has one of the below-mentioned values. The meaning of the field is also explained below.

01 return address selector 89 index used in erroneous indexing

InstructionsThe fault usually lies in the software or the packaging, so it isrecommended that you inform local technical support.

The alarm requires no further actions.

CancellingNo cancelling.

Page 75: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 75

Disturbance Printouts (1000-1999) 1082 HAND USAGE LIMIT EXCEEDED

Id:0900d805806a941aConfidential

46 1082 HAND USAGE LIMIT EXCEEDEDMeaning

The number of free hands of a hand type in a process family(indicated in the supplementary information fields of thisalarm) has dropped below the supervision threshold duringthe measurement period.

If there are no free hands of a certain hand type, that typeof hands cannot be reserved, and this may thus disturb thefunctioning of the computer.

Supplementary information fields1 family identifier

2 hand type identifier

3 minimum percentage of free hands in a given hand type during the supervision period

4 supervision limit percentage

5 minimum number of free hands in a given hand type during the supervision period

6 number of free hands in a given hand type at the end of the supervision period

InstructionsThe cause of the disturbance may be a fault or an overloadsituation, or an insufficient number of hands in a given handtype. Also, the supervision parameter values may be too low.

If the number of free hands in a given hand type has in factbeen small, increase the number of hands in the DXPARA fileused in the computer. The number of hands can be increased bypackaging a new file or by modifying the number of hands inthe file used in the exchange by means of the STYMIE serviceterminal extension. The modified number of hands will bevalid after the next loading restart of the computer.

CancellingNo cancelling.

Page 76: Descrption alarms - GSM NOKIA - 1000 à 1999

76 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1083 SEMAPHORE USE ERROR

47 1083 SEMAPHORE USE ERRORMeaning

The system has detected an error in a semaphore handling routine ofthe operating system kernel. The error may disturb the functioningof the erroneous application or the co-operation of applications.

Supplementary information fields1 family identifier of the process that called the routine where an error was detected

2 process identifier of the process that called the routine where an error was detected

3 error code describing the error detected. The possible values are:

257d error in semaphore name 258d attempt to use the semaphore in a way not allowed by protection 259d illegal attempt to initialize the semaphore 260d ENTER_REGION routine call in a critical area 261d EXIT_REGION routine call outside a critical area

4 selector part of the call return address

5 offset part of the call return address

InstructionsThere is a fault in the software or the packaging, so it isrecommended that you inform your local Nokia Siemens Networksrepresentative in order to find out the reason for the faultsituation.

The alarm requires no further actions.

CancellingNo cancelling.

Page 77: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 77

Disturbance Printouts (1000-1999) 1089 DYNAMIC LDT SLOTS EXHAUSTED

Id:0900d805806a941aConfidential

48 1089 DYNAMIC LDT SLOTS EXHAUSTEDMeaning

All the local descriptor table slots for the process family'sdynamic use are reserved and the reservation of a new slothas failed. The error disturbs the functioning of the processfamily and thus possibly the functioning of the whole computer.

The fault may be in packaging, that is, an insufficient number ofdynamic local descriptor table slots in comparison with thenumber of hand processes are reserved for a family. The faultmay also be in software, that is, too many slots are reserved.

The process family indicated in the supplementary informationfields of this alarm is not always the one whose descriptortable is full, because some operating system routines handletables other than the process family's own local descriptor table.This is especially the case when the family identifier is 108.

Supplementary information fields1 family identifier of the process that called the routine where an error was detected

2 process identifier of the process that called the routine where an error was detected

3 selector part of the call return address

4 offset part of the call return address

Instructions1. Output the resource information of the process family indicated in the alarm by using the DOI command. This will help to determine the fault. Useful information can also be obtained from the operating system log or the computer log.

2. Inform your local Nokia Siemens Networks representative about the fault.

CancellingNo cancelling.

Page 78: Descrption alarms - GSM NOKIA - 1000 à 1999

78 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1090 BUFFER HANDLE ERROR

49 1090 BUFFER HANDLE ERRORMeaning

A process has called a buffer handling routine with an incorrectbuffer handle. A typical situation is a failure in the release ofthe buffer, so that the buffer remains occupied by the process.

Supplementary information fields1 family identifier of the process that called the routine where an error was detected

2 process identifier of the process that called the routine where an error was detected

3 selector part of the call return address

4 offset part of the call return address

InstructionsThe fault is in the software, therefore, it is recommended that youinform your local Nokia Siemens Networks representative.

CancellingNo cancelling.

Page 79: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 79

Disturbance Printouts (1000-1999) 1092 COMMUNICATION FAILURE IN FIELD RE-PORTING

Id:0900d805806a941aConfidential

50 1092 COMMUNICATION FAILURE IN FIELD REPORTINGMeaning

Reading of traffic data from the statistical unit, or back-upcopying of field reporting files, has temporarily failed due toa fault, or overloading of statistics or the I/O system.The next regular or intermediate report may therefore containinformation that is inexact.

Supplementary information fields1 file number:

5C0000 = FACILI = subscriber facilities 4B0000 = SERLEV = service grade counters 5940000 = NORELC = service grade clear code counters 5930000 = DERELC = service grade counters by clear code group 6500000 = ACGAPP = service number counters

2 error code:

1d reading of traffic data failed 2d back-up copying failed

You can check the meaning of other error codes in General Error Messages of System

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 80: Descrption alarms - GSM NOKIA - 1000 à 1999

80 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1093 OUTPUT FAILURE IN FIELD REPORTING

51 1093 OUTPUT FAILURE IN FIELD REPORT-INGMeaning

The output of the regular field report has failed because the I/Osystem is overloaded, the I/O device is not in order, the logicaloutput file used to print the report is not properly connectedto the I/O device, buffer memory for making the report cannot bereserved, or a field reporting file cannot be opened.

Supplementary information fields1 error code given by I/O system.

General error message of the system. You can check its meaning in the General Error Messages of System

2 observation type:

00 subscriber facilities (FAC) 01 restarts (RES) 02 all grade of service data (SER) 03 intelligent network (IN) services (ACG) 04 number of calls in the exchange (TRF) 05 clear codes of all calls (CLR) 06 clear codes of one outgoing number destination (CLS) 07 clear code groups by number destinations (DES) 08 signalling specific clear codes of specified circuits (SSC) 09 data call clear code groups by number destination (DAT) 0A data call clear codes (DCL) 0B signalling specific clear codes of all circuits (SSCA)

InstructionsCheck that the I/O device used to print reports is in order andin correct working state (MML command ISI), and that the followinglogical output files have been connected to the said device:

Logical file Measurement type=======================================================================ascii bin xml

FIELFACA FIELFACB FIELFACX Field Reporting of facility usageFIELRESA FIELRESB FIELRESX Field Reporting of unit restartsFIELTRFA FIELTRFB FIELTRFX Field Reporting on trafficability performanceFIELCLRA FIELCLRB FIELCLRX Field Reporting on clear codesFIELCLSA FIELCLSB FIELCLSX Field Reporting on clear codes of one destinationFIELDESA FIELDESB FIELDESX Field Reporting on destination-specific

Page 81: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 81

Disturbance Printouts (1000-1999) 1093 OUTPUT FAILURE IN FIELD REPORTING

Id:0900d805806a941aConfidential

clear code groupsFIELACGA FIELACGB FIELACGX IN service gapping reportFIELASSA FIELASSB FIELASSX Signalling-specific clear code measurement report, part 2FIELSSCA FIELSSCB FIELSSCX Signalling-specific clear code measurement report, part 1FIELDATA FIELDATB FIELDATX Data call clear code group by number destination measurementFIELDCLA FIELDCLB FIELDCLX Data call clear code measurement

CancellingNo cancelling.

Page 82: Descrption alarms - GSM NOKIA - 1000 à 1999

82 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1095 TRAFFIC MEASUREMENT OUTPUT FAILURE

52 1095 TRAFFIC MEASUREMENT OUTPUT FAILUREMeaning

The traffic measurement report output on the I/O device used forprinting the report has failed.

Supplementary information fields1 measurement type

CGR CIRCUIT GROUPS DEST DESTINATIONS CNTL CONTROL UNITS SUBS SUBSCRIBERS TCAT TRAFFIC CATEGORIES BS CELLS SMO SUBSCRIBER MODULES ANN ANNOUNCEMENT CHANNELS CTD CIRCUIT GROUP TO DESTINATION DTD DESTINATION TO DESTINATION VAN VOICE ANNOUNCEMENT RSS REMOTE SUBSCRIBER STAGE BCH BEARER CHANNELS

2 error code 154d is output to this field, if no reply to the report output request is received from the RFGPRB program block. Otherwise, any of the error codes returned by the said program block is output. You can check their meaning in General Error Messages of System

InstructionsCheck that the operation and maintenace unit (OMU) is in state WO-EX.Check also that the output device connected to the logical file ofthe measurement in question is in order.

Logical file Measurement type=========================================================ascii bin xml

TRACGRA TRACGRB TRACGRX CIRCUIT GROUPSTRADESTA TRADESTB TRADESTX DESTINATIONSTRACNTLA TRACNTLB TRACNTLX CONTROL UNITSTRASUBSA TRASUBSB - SUBSCRIBERSTRATCATA TRATCATB TRATCATX TRAFFIC CATEGORIESTRASMOA TRASMOB - SUBSCRIBER MODULESTRABSA TRABSB TRABSX CELLSTRAANNA TRAANNB TRAANNX ANNOUNCEMENT CHANNELSTRACTDA TRACTDB TRACTDX CIRCUIT GROUP TO DESTINATION

Page 83: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 83

Disturbance Printouts (1000-1999) 1095 TRAFFIC MEASUREMENT OUTPUT FAILURE

Id:0900d805806a941aConfidential

TRADTDA TRADTDB TRADTDX DESTINATION TO DESTINATIONTRAVANA TRAVANB TRAVANX VOICE ANNOUNCEMENTTRARSSA TRARSSB - REMOTE SUBSCRIBER STAGETRABCHA TRABCHB - BEARER CHANNELS

CancellingNo cancelling.

Page 84: Descrption alarms - GSM NOKIA - 1000 à 1999

84 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1098 TOO LONG MESSAGE

53 1098 TOO LONG MESSAGEMeaning

A message to be received is longer than the area reserved formessage reception, therefore, receiving the message to theprocess data area was only partially successful.

If the process does not check whether message reception wassuccessful, the process may erroneously read information in thedata area outside the reception area as the end part of the message,and interpret that data according to message structure.

Supplementary information fields1 family identifier of the process that received a message to an insufficient reception area

2 process identifier of the process that received a message to an insufficient reception area

3 message length

4 message sender's computer

5 message sender's family identifier

6 message sender's process identifier

7 message number

InstructionsThe fault is in software or packaging, therefore, it is recommendedthat you inform your local Nokia Siemens Networks representative,in order to correct the fault situation.

The alarm requires no further actions.

CancellingNo cancelling.

Page 85: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 85

Disturbance Printouts (1000-1999) 1103 SIGNALLING MEASUREMENT REPORT LOST

Id:0900d805806a941aConfidential

54 1103 SIGNALLING MEASUREMENT REPORT LOSTMeaning

The forming or outputting of signalling measurement reportin the defined device has failed. The reason may be in thedefinition of the logical file used in the outputting of thereport, or in the switching, or the reason may be the wrongoperating state or overload of one of the I/O-devices whichthe logical file in question is linked with.

Supplementary information fields1 the lost report:

01 SIGNALLING LINK AVAILABILITY 02 SIGNALLING LINK PERFORMANCE 03 SIGNALLING LINK UTILIZATION 04 SIGNALLING POINT STATUS 05 SIGNALLING LINK SET AND ROUTE SET AVAILABILITY 06 SIF AND SIO OCTETS HANDLED WITH SIGNALLING POINT 07 SIF AND SIO OCTETS HANDLED WITH SIO 08 SIF AND SIO OCTETS HANDLED WITH OPC, DPC AND SIO 09 SCCP SIGNALLING POINT METERS 0A SCCP SUBSYSTEM METERS 0B SCCP LOCAL SUBSYSTEM AVAILABILITY 0C SCCP SINGLE METERS 0D TC PERFORMANCE AND UTILIZATION 0E TRANSMITTED AND RECEIVED FRAMES AND OCTETS ON D-CHANNEL 0F D-CHANNEL MISCELLANEOUS STATISTICAL METERS 10 Q.921 ERROR METERS 11 TC TRANSACTION METERS 20 SIGNALLING LINK INTERVAL LOG 21 MTP SIGNALLING POINT INTERVAL LOG 22 SCCP SIGNALLING POINT INTERVAL LOG 23 SCCP SEGMENTATION AND REASSEMBLY ERRORS INTERVAL LOG 24 TC INTERVAL LOG 25 SCCP GT TRANSLATION ERRORS LOG

2 the value 154d will be output in the field if RFGPRB program block gives no answer to the output request of the report. Otherwise some other general error code will be output. You can check the meaning of error codes in General Error Messages of System.

InstructionsMake sure that the operation and maintenance unit (OMU) is inthe WO-EX state. Make sure that the connection of the logical

Page 86: Descrption alarms - GSM NOKIA - 1000 à 1999

86 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1103 SIGNALLING MEASUREMENT REPORT LOST

file of the measurement in question is in order, i.e. thatthe logical file is further connected to another logical file(e.g. binary report file to the MEAFIL) or to a workingI/O-device.If the logical files of binary reports are connected to theMEAFIL file, make sure that the MEAFIL is connected to thevirtual data storing device (VDS).

Logical file Measurement type.............................................ascii bin

MTP measurement reports:MTPSLAVAIA MTPSLAVAIB SIGNALLING LINK AVAILABILITYMTPSLPERFA MTPSLPERFB SIGNALLING LINK PERFORMANCEMTPSLUTILA MTPSLUTILB SIGNALLING LINK UTILIZATIONMTPSPSTATA MTPSPSTATB SIGNALLING POINT STATUSMTPSLSAVAA MTPSLSAVAB SIGNALLING LINK SET AND ROUTE SET AVAILABILITYMTPOCTHSPA MTPOCTHSPB SIF AND SIO OCTETS HANDLED WITH SIGNALLING POINTMTPOCTSIOA MTPOCTSIOB SIF AND SIO OCTETS HANDLED WITH SIOMTPOCTMATA MTPOCTMATB SIF AND SIO OCTETS HANDLED WITH OPC, DPC AND SIO

SCCP/TC measurement reports:SCCPSPA SCCPSPB SCCP SIGNALLING POINT METERSSCCPSSA SCCPSSB SCCP SUBSYSTEM METERSSCCPLSSAVA SCCPLSSAVB SCCP LOCAL SUBSYSTEM AVAILABILITYSCCPSINGLA SCCPSINGLB SCCP SINGLE METERSTCAPPUA TCAPPUB TCAP PERFORMANCE AND UTILIZATIONTCAPTRANSA TCAPTRANSB TC TRANSACTION METERS

LAPD measurement reports:LAPDFROCA LAPDFROCB TRANSMITTED AND RECEIVED FRAMES AND OCTETS ON D-CHANNELLAPDMISCCA LAPDMISCCB D-CHANNEL MISCELLANEOUS STATISTICAL METERSLAPDQ921EA LAPDQ921EB Q.921 ERROR METERS

MTP interval log reports:MTPSLLOGA SIGNALLING LINK INTERVAL LOG REPORTMTPSPLOGA SIGNALLING POINT INTERVAL LOG REPORT

SCCP/TC interval log reports:SCCPSPLOGA SCCP SIGNALLING POINT INTERVAL LOG REPORTSCCPSGLOGA SCCP SEGMENTATION AND REASSEMBLY ERRORS INTERVAL

Page 87: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 87

Disturbance Printouts (1000-1999) 1103 SIGNALLING MEASUREMENT REPORT LOST

Id:0900d805806a941aConfidential

LOG REPORTTCLOGA TC INTERVAL LOG REPORTSCCPGTLOGA SCCP GT TRANSLATION ERRORS LOG REPORT

CancellingNo cancelling.

Page 88: Descrption alarms - GSM NOKIA - 1000 à 1999

88 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1105 LINE SIGNALLING RECEIVE OVERLOAD

55 1105 LINE SIGNALLING RECEIVE OVERLOADMeaning

The receiving of line signals is overloaded.

Supplementary information fields1 plug-in unit type

2 plug-in unit index

3 error code 0 the buffer of the signal receiver in the LST plug-in unit is full

1 the LSPPGM message buffer for received signals is full

2 the LSPPGM message buffer for supervision messages is full

3 the message buffer between the modules (RTC85-LSPREC) of the LSPPGM is full

4 all the filtering time counters of LSPPGM are in use

5 the message buffer for received signals in the AS7_U plug-in unit is full

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 89: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 89

Disturbance Printouts (1000-1999) 1125 TRIAL CONFIGURATION DELETED

Id:0900d805806a941aConfidential

56 1125 TRIAL CONFIGURATION DELETEDMeaning

The recovery system has deleted the trial configuration, becausea) in connection with the latest OMU restart, automatic returnchanged the software build to another because of a fault situationorb) a system restart occurred in a situation where the OMU (non-redundant)was not in the trial

Supplementary information fields1 error code which indicates the reason for deleting the trial configuration. You can check its meaning in General Error Messages of System.

InstructionsCheck the OMU BLACKBOX for the reason whya) the software build was changed during the latest restartorb) the OMU and the whole system was restarted.

CancellingNo cancelling.

Page 90: Descrption alarms - GSM NOKIA - 1000 à 1999

90 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1128 EXCESSIVE DISTURBANCES IN FILE LOAD-ING

57 1128 EXCESSIVE DISTURBANCES IN FILE LOADINGMeaning

File loading has been interrupted due to recurring errors.The unit is restarted to recover from the errors.

Supplementary information fields1 general error message of the system. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System

2 identifier of the family that detected the error USAPRO (A0): error detected by unit state administration FEMSER (2A3): error detected by file server for memory files lnx-dxfile-loader (705): error detected by Linux file loader The error may also be detected by a database manager

3 message bus address of the computer where the failed loading was executed

4 load group source 01 memory 02 disk

5 load type 01 virtual loading 02 immediate loading

6 load group

7 identifier of the file whose loading failed

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 91: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 91

Disturbance Printouts (1000-1999) 1136 SIGNALLING MESSAGE DISTRIBUTION ER-ROR

Id:0900d805806a941aConfidential

58 1136 SIGNALLING MESSAGE DISTRIBUTION ERRORMeaning

The alarm is issued when CCRECE receives from a signalling linka message which it cannot distribute to the user part concerned.

Supplementary information fields1 error code:

01 PCMCON file access error 02 COSPPC file access error 03 CIINTA file access error

2 value of service information octet (SIO) of received signalling message

3 value of destination point code of received signalling message

4 value of originating point code of received signalling message

5 value of signalling link selection field of received signalling message

6 the value of the circuit identification code field of such a received signalling message that contains the field, e.g. the signalling messages of the TUP and ISUP user parts

7-9 next three bytes after the user label in the signalling message received from the signalling link

InstructionsCheck whether the error is caused by the files or by a faultymessage.

CancellingNo cancelling.

Page 92: Descrption alarms - GSM NOKIA - 1000 à 1999

92 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1137 INCORRECT SIGNALLING MESSAGE FROM SIGNALLING TERMINAL

59 1137 INCORRECT SIGNALLING MESSAGE FROM SIGNALLING TERMINALMeaning

An erroneous signalling message has been received from a plug-in unit.There is a failure or a disturbance in the plug-in unit, or thecontent of the signalling message sent by the partner exchange isfaulty. The incoming signalling message is deleted, and if thedisturbance is caused by a faulty signalling terminal, the callsetup or call termination of a single call can be affected.

Supplementary information fields1 error detected in signalling message

01 signalling message is too long 02 service information octet is faulty

2 type of plug-in unit

3 index of plug-in unit

4 logical number of signalling terminal

5 value of service information octet (SIO) of received signalling message

6 value of destination point code of received signalling message

7 value of originating point code of received signalling message

8 value of signalling link selection field of received signalling message

InstructionsCheck with the MML command AHO if the alarm 2075(COMMUNICATION FAILURE BETWEEN SIGNALLING TERMINAL AND CCNETM)has been issued. If it is and the alarm 1137 has been givenonly once or very occasionally, act according to the instructionsof the alarm 2075.

The plug-in unit identified in supplementary information 2 and 3may be faulty. Perform a switchover of the alarm's target unitwith the MML command USC. Change into testing state the unitwhere the plug-in unit that is suspected faulty is located.Run diagnostics for the unit to find out whether the plug-in unitis faulty, see instructions on Diagnostics and Testing.

Page 93: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 93

Disturbance Printouts (1000-1999) 1137 INCORRECT SIGNALLING MESSAGE FROMSIGNALLING TERMINAL

Id:0900d805806a941aConfidential

Replace the plug-in unit, if diagnostics detects that it isfaulty. See Instructions for Replacing Plug-in Units.

Check also with the MML command AHP whether the alarm 2224(ERROR IN MSU HANDLING) has been issued. If it is, act accordingto its instructions.

If the cause of the disturbance was not discovered with theseactions, check out the log of the unit that issued the alarm withthe service terminal command ZGD. If the log text "INCORRECT MSGFROM TERM TYPE x" is found, store the contents of the terminalcontrol mailbox identified in the message's data for laterexamination. Store also the alarm history before and afterthe alarm 1137 was given and, if necessary, contact your localNokia Siemens Networks representative.

CancellingNo cancelling.

Page 94: Descrption alarms - GSM NOKIA - 1000 à 1999

94 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1140 FREE LDT SLOT COUNT BELOW LIMIT

60 1140 FREE LDT SLOT COUNT BELOW LIMITMeaning

The free dynamic LDT slot count of a process indicated in thesupplementary information fields of this alarm is below thesupervision limit indicated by the process.

The fault may be in packaging, that is, an insufficient number ofdynamic local descriptor table slots in comparison with thenumber of hand processes are reserved for a family. The faultmay also be in software, that is, too many slots are reserved orthe supervision limit is set to be unnecessarily high. In suchcase the slot count may fall below the limit even in normal operation.

In case the dynamic LTD slot count falls below the supervision limit,it is highly probable that the number of slots has been significantlyreduced, and the reason for this should be clarifiedimmediately.

When the family has no more dynamic LDT slots the family is restarted,which may interfere with the functioning of the computer. Disturbanceobservation 1089 is set when there are no more dynamic LDT slots.

Supplementary information fields1 family identifier of the process whose free dynamic LDT slot count is below the limit

2 number of family's free dynamic LDT slots

3 supervision limit

4 supervision interval in seconds

Instructions1. Display the resource status of the process family indicated in the additional information field of the alarm by using the MML command DOI.

2. Create a long-term family resource status measurement using the MML command DOF and start the measurement by giving the MML command DOG. The measurements are displayed to the logical file OSSTATREP. Connect the logical file OSSTATREP to I/O terminal using the MML command IIS.

3. Contact your local Nokia Siemens Networks representative. Displaying the resource status and providing these results speeds up the correction of the fault.

Page 95: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 95

Disturbance Printouts (1000-1999) 1140 FREE LDT SLOT COUNT BELOW LIMIT

Id:0900d805806a941aConfidential

CancellingNo cancelling.

Page 96: Descrption alarms - GSM NOKIA - 1000 à 1999

96 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1141 DELAY BUFFER OVERFLOW IN SIGNALLING TERMINAL

61 1141 DELAY BUFFER OVERFLOW IN SIG-NALLING TERMINALMeaning

The delay buffer of a plug-in unit is full. Messages are deletedwhen the delay buffer is in use, so that the signalling traffic isdisturbed. The overflow situation may be caused by overload or afailure in the plug-in unit. The alarm is issued when thereis a changeover or controlled rerouting.

Supplementary information fields1 plug-in unit type

2 plug-in unit index

3 logical number of signalling terminal

InstructionsCheck the amount of traffic on the channel concerned with theMML commands of statistics handling. You can obtain the amountof traffic on the channel, either for the last half hour orcumulatively, with the MML command OLU. If traffic is low,the plug-in unit might be faulty.

Perform a changeover for the target unit of the alarm with theMML command USC. Change into testing state the unit where theplug-in unit that is suspected faulty is located. Run diagnosticsfor the unit to find out whether the plug-in unit is faulty, seeinstructions on Diagnostics and Testing.

Replace the plug-in unit, if diagnostics detects that it is faulty.See Instructions for Replacing Plug-in Units.

Check also with the MML command AHP whether the alarm 2224,ERROR IN MSU HANDLING, has been issued. If it is, act according to itsinstructions.

CancellingNo cancelling.

Page 97: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 97

Disturbance Printouts (1000-1999) 1142 FAMILY MEMORY USAGE SUPERVISION LIM-IT EXCEEDED

Id:0900d805806a941aConfidential

62 1142 FAMILY MEMORY USAGE SUPERVI-SION LIMIT EXCEEDEDMeaning

The family indicated in the supplementary information fields of thisalarm has exceeded the supervision limit set to its memory use.During start up, the system allocates memory areas to the familybased on maximum memory use rate in normal functions.The system also supervises that this limit is not exceeded.the limit is exceeded, this alarm is set off.

Memory use of process families is supervised because a faulty familymay reserve a lot of memory and thus prevent otherprocesses from reserving memory. The failure to reserve memorydisturbs the functioning of the processes and the computer.Depending on the functions of the computer, traffic capacity orcharging may be disturbed.

Supplementary information fields1 family identifier

2 family's memory use percentage observed by supervision

3 supervision limit percentage

4 memory, in kilo bytes, allocated to the family at the time of the supervision. If it exceeds 64 MB, the value is FFFF

5 free memory, in kilo bytes, at the time of the supervision. If it exceeds 64 MB, the value is FFFF

6 memory, in kilo bytes, allocated to the family at the end of the supervision period. If it exceeds 64 MB, the value is FFFF

7 free memory, in kilo bytes, at the end of the supervision period. If it exceeds 64 MB, the value is FFFF

Instructions1. Check whether the disturbance is caused by an overload situation. In an overload situation an increased number of reserved hands and unhandled messages for a certain process family can result in unexpected memory exhaust.

2. Display the resource status of the process family indicated in the additional information field of the alarm by using the MML command DOI. This speeds up the diagnosis and correction of the fault.

Page 98: Descrption alarms - GSM NOKIA - 1000 à 1999

98 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1142 FAMILY MEMORY USAGE SUPERVISION LIM-IT EXCEEDED

3. If there is no overload, contact your local Nokia Siemens Networks representative to detect a possible fault in software. Displaying information on memory use and providing these results speeds up the correction of the fault.

CancellingNo cancelling.

Page 99: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 99

Disturbance Printouts (1000-1999) 1143 AMOUNT OF FREE MEMORY REDUCED

Id:0900d805806a941aConfidential

63 1143 AMOUNT OF FREE MEMORY REDUCEDMeaning

The amount of free memory in the computer is below the alarm limitused in supervision.

If the computer runs out of free memory, memory allocation failsand may disturb the functioning of the computer.

The size of the largest unified memory area is used as the freememory amount, as its size is more in accordance with the availablefree memory amount than the total free memory amount.

Supplementary information fields1 size of the biggest free buffer

2 alarm limit used in supervision

3 total free memory amount

4 total memory amount in memory administration

InstructionsThe reduction in free memory may result from an error in softwareor from a computer whose memory is too small for the software package.Use the MML command DOI to investigate the computer's memory use fordifferent purposes.

To find out the nature and cause of the situation, send the informationon memory use to your local Nokia Siemens Networks representative.

The alarm limit used in supervision can be modified with the MML commandDOM, parameter MEML.

CancellingNo cancelling.

Page 100: Descrption alarms - GSM NOKIA - 1000 à 1999

100 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1144 FREE BUFFER HEADERS EXHAUSTING

64 1144 FREE BUFFER HEADERS EXHAUSTINGMeaning

The number of free buffer headers is below the alarm limit usedin supervision. This indicates an increased risk of running outof free buffer headers. When there are no more free buffer headersthe computer must be restarted.

The fault may be in packaging or software, resulting in an insufficientoverall number of buffer headers or one of the process familiesreserving too many headers. It is also possiblethat the supervision limit has been set to be unnecessarily high,in which case an alarm is set too early.

Supplementary information fields1 number of free buffer headers

2 alarm limit used in supervision

3 total number of buffer headers

Instructions1. Check the current value of the parameter BUFFER HEADER SUPERVISION LIMIT by using the MMl command DOT. If the value is unnecessarily high, decrease it by giving the MML command DOM according to the instructions of the Nokia Siemens Networks representative.

2. If the value of this parameter is 100 or below, contact your local Nokia Siemens Networks representative to detect a possible fault in packaging or software.

CancellingNo cancelling.

Page 101: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 101

Disturbance Printouts (1000-1999) 1147 MESSAGE QUEUE OVERFLOW

Id:0900d805806a941aConfidential

65 1147 MESSAGE QUEUE OVERFLOWMeaning

The message queue of the process has reached its defined maximumlength and the message sent to the process is deleted.

Supplementary information fields1 family identifier of the process whose message queue is full

2 process identifier of the process whose message queue is full

3 sender computer of the deleted message

4 sender family identifier of the deleted message

5 sender process identifier of the deleted message

6 deleted message number

InstructionsThe fault lies in software or packaging, therefore, it is recommendedthat you inform your local Nokia Siemens Networks representative,in order to detect the reason for the fault.

The alarm requires no further actions.

CancellingNo cancelling.

Page 102: Descrption alarms - GSM NOKIA - 1000 à 1999

102 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1148 EXCESSIVE TRAPS

66 1148 EXCESSIVE TRAPSMeaning

The number of traps exceeds the alarm limit duringthe supervision interval.

Traps are produced when the program uses an insufficient or faulty memoryor, for example, a faulty addtional plug-in unit.Traps do not usually disturb the functioning of the program producingthem, but they indicate a disturbance either in the hardware, software orin the data that the program uses. If the fault is related to hardware,the system normally gives other alarms as well.

The address formed by CS and EIP is an address where the programexecution was when the trap was detected, that is, the addressdescribes the program's general execution area rather than aspecific memory addressing execution area.

Supplementary information fields1 number of traps during supervision interval

2 alarm limit used in supervision

3 identifier of the family that caused the latest trap

4 identifier of the process that caused the latest trap

5 register's CS value at the moment of the latest trap detection

6 register's EIP value at the moment of the latest trap detection

Instructions1. If the system has not given alarms on hardware faults, check the equipment data with the MML commands of WT command group. If the equipment data is correct or if you do not succeed in correcting the fault, contact your local Nokia Siemens Networks representative.

2. Operating system logs have been written in the OSSUPREP logical file and studying those can help you in locating the fault. Check with the MML command ZDOP whether parameter SENDING OF REPORTS is allowed. If the parameter is not allowed, allow it with the MML command ZDOM. Connect the OSSUPREP logical file to the I/O terminal available with the MML command ZIIS.

3. If the fault is a hardware fault, you can temporarily prevent the alarm from rising repeatidly by modifying the alarm limit of the object unit with the MML command ZDOM, or,

Page 103: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 103

Disturbance Printouts (1000-1999) 1148 EXCESSIVE TRAPS

Id:0900d805806a941aConfidential

you can disable the supervision in all the units that are of the same unit type as the object unit with the MML command ZDOM. After the fault has been repaired, change the alarm limit back to normal and re-enable the supervision.

CancellingNo cancelling.

Page 104: Descrption alarms - GSM NOKIA - 1000 à 1999

104 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1162 FILE SYSTEM COMMUNICATION ERROR

67 1162 FILE SYSTEM COMMUNICATION ERRORMeaning

The file system program block is not responding to a message withinthe allowed time limit or its answer is erroneous. If the programblock has not answered the message within the allowed time limit,there may be discrepancies between files in the units.

Supplementary information fields1 location unit type of the partner program block

2 location unit index of the partner program block

3 family identifier of the partner program block

4 number of the message sent to the partner program block

5 number of the file in connection to which the error was detected. If the value is FFFFFFFF, the file number cannot be identified

6 error code returned by the partner program block. You can check its meaning in the General Error Messages of System.

InstructionsUse the MML command AHO to check whether there are other active alarmsconcerning the file system. Check also possible logs connected tothe file system in the unit identified by the first and secondsupplementary fields with the S command of the service terminalextension LOGUTI. Locate and correct the fault with the help of thelogs and the error code given in the final supplementary field of thisalarm.

CancellingNo cancelling.

Page 105: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 105

Disturbance Printouts (1000-1999) 1165 BUFFER ALLOCATION FAILED

Id:0900d805806a941aConfidential

68 1165 BUFFER ALLOCATION FAILEDMeaning

A process failed to reserve a buffer because the buffer sizerequested by the process is larger than the largest freebuffer.

Buffer reservation failure may prevent the execution of atask or make it slower.

Supplementary information fields1 family identifier of the process whose buffer reservation failed

2 process identifier of the process whose buffer reservation failed

3 requested buffer size

4 largest free buffer

5 total amount of free memory

InstructionsThe fault may be in software or in a computer unit whosememory is too small for the software and functions requiredof it. A software fault is probable, if the requested buffersize indicated in the supplementary information field islarge in comparison with the computer memory.

If the total amount of free memory indicated in thesupplementary information field seems adequate but also thelargest free buffer (indicated in the supplementaryinformation field) is small, the memory is fragmented. Even ahot restart of a computer would cause the rearranging of freeand reserved buffers, so that the largest free buffer wouldprobably become larger.

If a buffer reservation fails in connection with a criticaltask, the maintenance system restarts the computer, andusually the memory state also returns to normal.

If the total amount of free memory is small, the computerprobably has an insufficient memory capacity and should bereplaced with one that has more capacity.

In any case, it is recommended to inform your local NokiaSiemens Networks representative on the fault. Include information on

Page 106: Descrption alarms - GSM NOKIA - 1000 à 1999

106 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1165 BUFFER ALLOCATION FAILED

the memory, i.e. on the division of free memory and theprocess families that have reserved memory the most.

CancellingNo cancelling.

Page 107: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 107

Disturbance Printouts (1000-1999) 1169 FREEZING PERIOD OF SS7 REPORTINGLOST

Id:0900d805806a941aConfidential

69 1169 FREEZING PERIOD OF SS7 REPORT-ING LOSTMeaning

Some of the counters or logs of the SS7 statistics are not reported,because the counters or log events in question are lost from thefiles.

If the alarm concerns counter reporting, the following two 30-minutefreezing periods have passed during the report outputting, and thusthe counters of the first reporting period are lost. The counters ofthe freezing period in question will not be included to the followingreporting period.

If the alarm concerns reporting of interval logs,the 5-minute freezing period has finished before the log events of theprevious 5-minute period are reported. In this case, the log events inquestion are not reported, but they are available with MML commands.

Supplementary information fields1 type of counters or logs lost:

01 MTP counters 02 SCCP/TC counters 03 MTP interval logs 04 SCCP/TC interval logs

2 file number of the counter or log file whose counters or logs were not reported. If the file number is not available, the value of the field is FFFFFFFF

InstructionsCheck that the operation and maintenance computer (OMU) is in workingstate WO-EX with the MML command USI.

Check that the connections of the logical files of the SS7 reportingare in order with the MML command IID, that is, that the logical filesare connected onwards to another logical file (for example binaryreports' files to MEAFIL file) or to a functioning I/O device(for more information, see instructions on I/O System).

If the binary reports' logical files are connected to MEAFIL file,also check that MEAFIL is connected to a virtual data storage (VDS).

The reason for the alarm may also be the overload of reporting, inwhich case, reports are not outputted fast enough. In this case,decrease the report load by removing unnecessary signalling channels,signalling points and/or SCCP subsystems from the statistics with

Page 108: Descrption alarms - GSM NOKIA - 1000 à 1999

108 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1169 FREEZING PERIOD OF SS7 REPORTING LOST

the MML commands OSL, OSN OSE, and possibly unnecesary reportingtypes with the MML commands OSM and OSG.

Logical file Measurement type======================================================ascii bin

MTP counters:MTPSLAVAIA MTPSLAVAIB SIGNALLING LINK AVAILABILITYMTPSLPERFA MTPSLPERFB SIGNALLING LINK PERFORMANCEMTPSLUTILA MTPSLUTILB SIGNALLING LINK UTILIZATIONMTPSPSTATA MTPSPSTATB SIGNALLING POINT STATUSMTPSLSAVAA MTPSLSAVAB SIGNALLING LINK SET AND ROUTE SET AVAILABILITYMTPOCTHSPA MTPOCTHSPB SIF AND SIO OCTETS HANDLED WITH SIGNALLING POINTMTPOCTSIOA MTPOCTSIOB SIF AND SIO OCTETS HANDLED WITH SIOMTPOCTMATA MTPOCTMATB SIF AND SIO OCTETS HANDLED WITH OPC, DPC AND SIO

SCCP/TC counters:SCCPSPA SCCPSPB SCCP SIGNALLING POINT METERSSCCPSSA SCCPSSB SCCP SUBSYSTEM METERSSCCPLSSAVA SCCPLSSAVB SCCP LOCAL SUBSYSTEM AVAILABILITYSCCPSINGLA SCCPSINGLB SCCP SINGLE METERSTCAPPUA TCAPPUB TCAP PERFORMANCE AND UTILIZATIONTCAPTRANSA TCAPTRANSB TC TRANSACTION METERS

MTP interval logs:MTPSLLOGA SIGNALLING LINK INTERVAL LOG REPORTMTPSPLOGA SIGNALLING POINT INTERVAL LOG REPORT

SCCP interval logs:SCCPSPLOGA SCCP SIGNALLING POINT INTERVAL LOG REPORTSCCPSGLOGA SCCP SEGMENTATION AND REASSEMBLY ERRORS INTERVAL LOG REPORTTCLOGA TC INTERVAL LOG REPORTSCCPGTLOGA SCCP GT TRANSLATION ERRORS LOG REPORT

CancellingNo cancelling.

Page 109: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 109

Disturbance Printouts (1000-1999) 1178 PREPROCESSOR UNIT DISTURBANCE

Id:0900d805806a941aConfidential

70 1178 PREPROCESSOR UNIT DISTURBANCEMeaning

Functioning of a program block in a preprocessor is not normal.Either start-up of the program block has failed or the programblock does not send an answer to the supervision message.

Supplementary information fields1 type of the preprocessor plug-in unit

2 index of the preprocessor plug-in unit

3 general error message of the system telling the reason for the alarm. You can check its meaning in the General Error Messages of System.

4 family identifier of the program block that the alarm concerns

InstructionsThe alarm requires no immediate actions. However, if the alarm occursrepeatedly, fill in a Problem Report and send it to your local NokiaSiemens Networks representative.

CancellingNo cancelling.

Page 110: Descrption alarms - GSM NOKIA - 1000 à 1999

110 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1182 PREPROCESSOR UNIT RESTARTED

71 1182 PREPROCESSOR UNIT RESTARTEDMeaning

A preprocessor has restarted spontaneously. If the preprocessor isequipped into a unit which working state is WO-EX, the restart causesdisturbance to the function of the unit.

Supplementary information fields1 type of the restarted preprocessor plug-in unit

2 index of the restarted preprocessor plug-in unit

InstructionsThe alarm requires no actions. It supports the activation of theautomatic recovery for the object unit. You can check the supportingamount of the alarm with the MML command ARO.

CancellingNo cancelling.

Page 111: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 111

Disturbance Printouts (1000-1999) 1190 EXCESSIVE ERRORS IN SCP

Id:0900d805806a941aConfidential

72 1190 EXCESSIVE ERRORS IN SCPMeaning

Statistics measure the ratio between failed transactions and alltransactions between the SCP and the SSP. The measurement is performedon the global titles of the SCP with the MML command TDC.

If the ratio between failed transactions and the total number oftransactions exceeds a given limit at the end of a period, and thetotal number of transactions does not exceed a given limit, then thisdisturbance for the global title defined is printed.

This function has, in the class 9 of the parameter file, the parametersobservation period (15), error ratio alarm limit (14), and limit forthe total number of transactions (13).

Supplementary information fields1-8 SCP global title: there are two digits in each byte. If there is an odd number of digits, the meaningless digit is FH and the rest FFH (e.g. the global title 123 is printed 12 3F FF FF FF FF FF FF).

9 the number of all transactions in SCP during the observation period

10 the value of the error ratio that caused the alarm

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 112: Descrption alarms - GSM NOKIA - 1000 à 1999

112 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1200 ACTOR HAS FAILED TO REGISTER TO THE SUPERVISION

73 1200 ACTOR HAS FAILED TO REGISTER TO THE SUPERVISIONMeaning

An actor has failed to register to the active supervision.

It is possible that the supervision data table has filled up. Thismeans that the actor supervisor (SVATOR) cannot take more actorsunder the active supervision. The problem has no effect on theactor supervision already activated.

Apart from the active supervision, all actors are supervisedpassively, i.e. exceptions made by the actors are always noticed.

If the actor is not supervised actively, the erroneous behaving(e.g. infinite loops) or the total stopping of the actor is notdetected and the recovery actions are not activated. However, ifthe actor runs without problems the lack of active supervision isnot a serious problem.

Supplementary information fields1 the DMX family identifier of an actor that has failed to register to the supervision

InstructionsIf the alarm occurs, the supervision data table is full.Fill in a Failure Report and send it to your localNokia Siemens Networks representative.

List the content of the supervision data table with service terminalcommand: supervise -a all and attach it to the Failure Report.

CancellingNo cancelling.

Page 113: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 113

Disturbance Printouts (1000-1999) 1204 WATCHDOG CAUSES UNIT RESTART

Id:0900d805806a941aConfidential

74 1204 WATCHDOG CAUSES UNIT RESTARTMeaning

A critical actor for the functioning of the unit has failed.This kind of actors are e.g. QXFPRB, which activates the recoveryfunctions and DAQTOR, which takes care of starting other actors.

Actor Supervisor (SVATOR) stops feeding the watchdog feeder actorand this will cause a unit restart.

Supplementary information fields

InstructionsThe alarm requires no actions because the coming unit restartsolves the problem.

CancellingNo cancelling.

Page 114: Descrption alarms - GSM NOKIA - 1000 à 1999

114 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1207 UNITS WORKING STATE DATA CORRUPTED IN THE SYSTEM

75 1207 UNITS WORKING STATE DATA COR-RUPTED IN THE SYSTEMMeaning

Working state data in the memory of the supervised unit is differentfrom the working state data of the supervised unit in the memory ofthe supervising unit. The system detects this divergence by itselfand begins the actions in order to correct the problem.

This data divergence can be caused by message transfer errors duringthe distribution of the working states to functional units. It maycause malfunctioning of the system, and it slows down or may evenprevent the automatic recovery actions in the system.

Supplementary information fields1 working state of the supervised unit in the memory of the system maintenance unit

2 working state of the supervised unit in the unit's own memory

InstructionsIf the disturbance occurs frequently, fill in a Problem Report andsend it to your local Nokia Siemens Networks representative.Otherwise, no action is required.

CancellingNo cancelling.

Page 115: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 115

Disturbance Printouts (1000-1999) 1210 PHASE ADVANCE OF TIMING SIGNALCHANGED

Id:0900d805806a941aConfidential

76 1210 PHASE ADVANCE OF TIMING SIGNAL CHANGEDMeaning

The phase advance setting of a rack has either been changedto the default value or updated according to the phase advancemeasurement result.

If the default phase advance value was taken into use, thefunctional units of the rack which are located far enoughfrom the main clock may have synchronisation problems withthe basic timing signals.

If the phase advance value of the rack was updated when somefunctional units had synchronisation problems, thesynchronisation after the updating should work better. Thisis the case especially when the difference of the old andnew phase advance value is big enough. If the difference wasonly a few measurement units, the updating may have noeffects on the basic timing distribution of functional unitsin the rack.

Supplementary information fields1 reason for phase update made:

00 the default phase advance was taken into use because the phase advance setting according to the automatic phase advance measurement is not possible due to the measurement result changing all the time. The reason for a measurement failure is typically the last rack where the timing bus is terminated. If the CLAB units of the last rack are without power supply or plug-in units of the CLAB are removed, the automatic phase advance measurement fails

01 the phase advance was updated. The difference between the phase advance value used and the measurement value was too big and updating was needed. The phase advance is updated typically after maintenance concerning the timing signals or when the default phase advance was in use due to the automatic phase advance measurement problems

2 old phase advance value

3 new phase advance value

Page 116: Descrption alarms - GSM NOKIA - 1000 à 1999

116 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1210 PHASE ADVANCE OF TIMING SIGNAL CHANGED

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 117: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 117

Disturbance Printouts (1000-1999) 1220 HANDLING OF MEASUREMENT DEFINITIONFILE FAILED

Id:0900d805806a941aConfidential

77 1220 HANDLING OF MEASUREMENT DEFINI-TION FILE FAILEDMeaning

Handling of measurement definition file has failed. There may be atemporary overload in the I/O-system. The changes, which have possiblybeen made have not been updated to the file. The measurement continuesusing the changed parameters, but in a possible restart situationthe system will continue the measurement using the old parameters.This means that the schedule of the measurement may not be correct.

The third and fourth supplementary information fields showthe reason for the failure.

Supplementary information fields1 measurement identifier. You can check its meaning by using the MML command T2C.

2 measurements object list identifier (from 1 to 999). You can check its meaning by using the MML command T2C.

3 failed task: 01 Writing of measurement definition file failed 02 Passifying of measurement definition file failed

4 specified reason for the error case shown in the third supplementary information field. This is a general error message of the system. You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document the General Error Messages of System, Supplementary References

InstructionsIf the third supplementary information field has the value 01, themeasurement is continued, but the parameters have not been updated to disk.The wrong parameters are shown when interrogating the measurementparameters (T2I MML-command). This may be due to a temporary overloadin the I/O-system. Check the I/O-system's active alarms and follow thosealarm instructions. You can try to write on the disk again when theI/O-system has recovered by modifying the measurement schedule(T2M MML-command), or the schedule is also updated to the disk every night at01.00 am, so these updates could correct the problem.If not, (the disturbance still occurs), contact your localNokia Siemens Networks representative. Send the unit's logs, operatingsystem logs and active alarms to your Nokia Siemens Networks representative.The logs can be output by using the service terminal commands ZGDand ZSL. The active alarms can be output by using the MML command ZAHO.

Page 118: Descrption alarms - GSM NOKIA - 1000 à 1999

118 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1220 HANDLING OF MEASUREMENT DEFINITION FILE FAILED

If the third supplementary information field has value 02, remove themeasurement definition file (T2D MML-command) which could not bepassified by the system. This may be due to a temporary overloadin the I/O-system. The name of the file is AMEASxxx.yyy,where xxx refers to the MID value (first supplementary information field)in the alarm, and yyy refers to the OID (second supplementary informationfield) value in the alarm.

CancellingNo cancelling.

Page 119: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 119

Disturbance Printouts (1000-1999) 1221 STATISTICAL MEASUREMENT REPORT OUT-PUT FAILED

Id:0900d805806a941aConfidential

78 1221 STATISTICAL MEASUREMENT REPORT OUTPUT FAILEDMeaning

Outputting the statistical measurement report has failed. The report ofthe measurement, which has caused the alarm may disappear or, if themeasurement report is output, the data in it may be faulty. The thirdand fourth supplementary information fields show the reason for thefailure.

Supplementary information fields1 measurement identifier of the report. You can check its meaning by using the MML command T2C.

2 measurements object list identifier (from 1 to 999). You can check its meaning by using the MML command T2C.

ERROR_CASE:

the reason for outputting of report failed: 01 Buffer allocation failed 02 No data writing service provider 03 Error with data writing service provider

3 specified reason when the third supplementary information field has value 03. This is a general error message of the system. You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document the General Error Messages of System, Supplementary References.

InstructionsIf the third supplementary information field has the value 01, there is anerror situation, which probably cannot be corrected without a softwareupdate. Contact your local Nokia Siemens Networks representative. Send theunit's logs, operating system logs and active alarms to your Nokia SiemensNetworks representative. The logs can be output by using the serviceterminal commands ZGD and ZSL. The active alarms can be output by usingthe MML command ZAHO.

If the third supplementary information field has the value 02, the servicemay be temporarily unobtainable. If this is continuous, there is an errorsituation which probably cannot be corrected without a software update.Contact your local Nokia Siemens Networks representative. Send the unit'slogs, operating system logs and active alarms to your Nokia Siemens Networksrepresentative. The logs can be output by using the service terminal commandZGD and ZSL. The active alarms can be output by using the MML command ZAHO.

Page 120: Descrption alarms - GSM NOKIA - 1000 à 1999

120 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1221 STATISTICAL MEASUREMENT REPORT OUT-PUT FAILED

If the third supplementary information field has the value 03, check thatthe I/O device used in the outputting of the report is in working order andin the correct working state (MML command ISI) and that the logical outputfile is connected to the device in question (MML command IID). Moreinformation on the administration of I/O devices can be found in I/OConfiguration Handling, Command Reference Manual.

CancellingNo cancelling.

Page 121: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 121

Disturbance Printouts (1000-1999) 1222 DATA WRITING VIA VDS DEVICE FAILED

Id:0900d805806a941aConfidential

79 1222 DATA WRITING VIA VDS DEVICE FAILEDMeaning

Data writing via the VDS device has failed. The report of the measurementthat has caused the alarm may disappear. The second and third supplementaryinformation fields show the reason for the failure.

Supplementary information fields1 measurement identifier of the report. You can check its meaning by using the MML command T2C.

2 the reason for data writing to fail: 01 Error in I/O system. 02 No response from I/O system 03 Memory allocation failed

3 specified reason for the error case shown in the second supplementary information field. This is a general error message of the system. You can check its meaning with a command of the service terminal extension MRS (see Service Terminal Essentials, Maintenance Manual) or from the document the General Error Messages of System, Supplementary References.

InstructionsIf the second supplemetary information field has the value 01 or 02,The I/O-system may be overloaded, and thus the report output fails.The situation may be temporary and the system will correct it.Check the I/O-system's active alarms and follow those alarm instructions.If the disturbance occurs constantly, contact your local Nokia SiemensNetworks representative. Send the unit's logs, operating system logs andactive alarms to the Nokia Siemens Networks representative.The logs can be output by using the service terminal command ZGD and ZSL.The active alarms can be output by using the MML command ZAAP.

If the second supplemetary information field has the value 03, there is anerror situation which probably cannot be corrected without a softwareupdate. Contact your local Nokia Siemens Networks representative.Send the unit's logs, operating system logs and active alarms to theNokia Siemens Networks representative. The logs can be output by usingthe service terminal command ZGD and ZSL. The active alarms can be outputby using the MML command ZAAP.

CancellingNo cancelling.

Page 122: Descrption alarms - GSM NOKIA - 1000 à 1999

122 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1228 UNIT SUPERVISION NOT FUNCTIONING

80 1228 UNIT SUPERVISION NOT FUNCTION-INGMeaning

The supervision of the functional unit(s) is not functioning because ofa technical problem, or the supervision is stopped by the userfor a special reason. If the supervision is stopped by the user,the system starts it automatically after a while (in less than one hour).

The lack of supervision does not prevent normal operation of the system,but it slows down or may even prevent the automatic recovery actions ofthe unsupervised unit.

Supplementary information fields1 failure reason:

01 User has stopped the unit supervision 02 Unit supervision has been stopped because of a technical problem

2 functional unit whose supervision has been stopped:

0xFFFF Supervision of all units stopped

phys_address_t Physical address of the unit whose supervision has been stopped or technical problem prevents the supervision to this unit.

InstructionsIf the supervision has not been stopped by user and if the disturbanceoccurs frequently, fill in a Problem Report and send it to your localNokia Siemens Networks representative. Otherwise, no action isrequired.

CancellingNo cancelling.

Page 123: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 123

Disturbance Printouts (1000-1999) 1234 UPDATE OF PASSWORD VALIDITY TIMEFAILED

Id:0900d805806a941aConfidential

81 1234 UPDATE OF PASSWORD VALIDITY TIME FAILEDMeaning

The program block of the user management (URMANA) has failedupdating the validity times of the MMI users' passwords.The validity times of the passwords remain unchanged.

Supplementary information fields1 reason for failure of the password validity time updating 01 error in writing of the memory file 02 error in writing of the disk file 03 creation of hand failed

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 124: Descrption alarms - GSM NOKIA - 1000 à 1999

124 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1240 SCCP DISTURBANCE

82 1240 SCCP DISTURBANCEMeaning

Report on SCCP disturbances.

Supplementary information fields1 identifier of disturbance. Possible values are:

01 releasing connection failed, as no acknowledgement has been received 02 abnormal release of connection, the time supervision of the passive receiving time (IAR) has expired 03 abnormal release of connection, erroneous IT message 04 abnormal release of connection, time supervision of the hand has expired 05 establishing connection failed, the time supervision of the connection establishment (CONN_EST) has expired 06 establishing connection failed, as the local subsystem has not responded to the connection request 07 subsystem does not respond to local sending 08 local subsystem has no counterpart 09 sending a signalling message to the subsystem fails, as the subsystem has not enrolled for the service 0A sending message to user has failed 0B sending message to MTP has failed 0C SCCP management could not locate the signalling unit being distributed 0D sending signalling message to a subsystem fails, as the standard of the TCAP message is different from the TCAP version used by the subsystem 0E message is rejected because its priority is lower than the overload level of the MTP

2 network indicator. Possible values are:

00 international network 0 04 international network 1 08 national network 0 0C national network 1

3 local signalling point code. The signalling point code is interpreted, depending on the value of the first supplementary information field, in the following manner:

01-06 own signalling point where the error was detected 07-08 own signalling point to whose subsystem the local sending was attempted 09-0E own signalling point

Page 125: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 125

Disturbance Printouts (1000-1999) 1240 SCCP DISTURBANCE

Id:0900d805806a941aConfidential

4 local subsystem number. If the local subsystem is not known, the value in the field is FF. The subsystem number is interpreted, depending on the value of the first supplementary information field, in the following manner:

01-06 local subsystem, releasing or establishing connection to which failed 07-08 local subsystem to which local sending was attempted (important subsystem) 09-0A local subsystem to which local sending was attempted 0B local subsystem from which the message was received 0C SCCP management subsystem 0D local subsystem to which sending a TCAP message was attempted 0E local subsystem from which a message was received

5 remote signalling point code. The signalling point code is interpreted, depending on the value of the first supplementary information field, in the following manner:

01-06 signalling point of the remote end signalling connection part 07-08 object signalling point of local sending, whose data is being distributed 09-0A signalling point from which the message came 0B local subsystem to which sending a message was attempted 0C local subsystem to which sending an SCCP management message was attempted 0D signalling point from which a TCAP message was received 0E signalling point to which sending a TCAP message was attempted

6 remote subsystem number. If the subsystem number is not known, the value in the field is FF. The subsystem number is interpreted, depending on the value of the first supplementary information field, in the following manner:

01-06 remote end subsystem of the signalling connection 07-08 object subsystem of local sending, whose data is being distributed 09-0A subsystem which send the message 0B remote end subsystem, sending the message to which was attempted 0C SCCP management subsystem, sending the SCCP management message to which was attempted 0D subsystem which has send a TCAP message 0E remote end subsystem to which sending a message was attempted

7 reference number in the DX log. The log contains more information on the error. If the reference number is not

Page 126: Descrption alarms - GSM NOKIA - 1000 à 1999

126 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1240 SCCP DISTURBANCE

used in the log, the value of the field is 0.

InstructionsIf the alarm is given infrequently and the value of the error codegiven in the first supplementary information field is 1-6, noactions are required from the user.

Otherwise fill in a Problem report and send it to your local NokiaSiemens Networks representative. Enclose the printouts output with theservice terminal commands ZSCFE, ZGSC and ZSL in the Problem report.

CancellingNo cancelling.

Page 127: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 127

Disturbance Printouts (1000-1999) 1241 SCCP GLOBAL TITLE TRANSLATION ANALY-SIS FILE ERROR

Id:0900d805806a941aConfidential

83 1241 SCCP GLOBAL TITLE TRANSLATION ANALYSIS FILE ERRORMeaning

Report on the analysis disturbances of the SCCP global titletranslation. The global title analysis was not completed becausethe analysed number was not found in the analysis data. The alarmmay have some effect on the traffic capacity of the system.A message that contains the global title in question will not getto its destination.

Supplementary information fields1 error code. Possible values are:

01 unknown nature of address indicator. There is no analysis for this nature of address indicator in the GANFIL

02 unknown numbering plan. There is no analysis for this numbering plan in the GANFIL

03 unknown translation type. There is no analysis for this translation type in the GANFIL

04 unknown encoding scheme. There is no analysis for this encoding scheme in the GANFIL

05 unknown global title indicator. There is no analysis for this global title indicator in the GANFIL

06 unknown global title standard. There is no analysis for this global title indicator in the GANFIL

11 GANFIL contains no analysis for the first digit of the address

12 GANFIL contains no analysis for the second digit of the address

13 GANFIL contains no analysis for the third digit of the address

14 GANFIL contains no analysis for the fourth digit of the address

15 GANFIL contains no analysis for the fifth digit of the address

16 GANFIL contains no analysis for the sixth digit of the address

Page 128: Descrption alarms - GSM NOKIA - 1000 à 1999

128 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1241 SCCP GLOBAL TITLE TRANSLATION ANALY-SIS FILE ERROR

17 GANFIL contains no analysis for the seventh digit of the address

18 GANFIL contains no analysis for the eighth digit of the address

19 GANFIL contains no analysis for the ninth digit of the address

1A GANFIL contains no analysis for the tenth digit of the address

1B GANFIL contains no analysis for the 11th digit of the address

1C GANFIL contains no analysis for the 12th digit of the address

1D GANFIL contains no analysis for the 13th digit of the address

1E GANFIL contains no analysis for the 14th digit of the address

1F GANFIL contains no analysis for the 15th digit of the address

20 GANFIL contains no analysis for the 16th digit of the address

21 GANFIL contains no analysis for the 17th digit of the address

22 GANFIL contains no analysis for the 18th digit of the address

23 GANFIL contains no analysis for the 19th digit of the address

24 GANFIL contains no analysis for the 20th digit of the address

25 GANFIL contains no analysis for the 21st digit of the address

26 GANFIL contains no analysis for the 22nd digit of the address

27 GANFIL contains no analysis for the 23rd digit of the address

Page 129: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 129

Disturbance Printouts (1000-1999) 1241 SCCP GLOBAL TITLE TRANSLATION ANALY-SIS FILE ERROR

Id:0900d805806a941aConfidential

28 GANFIL contains no analysis for the 24th digit of the address

2 record number of the GANFIL

3 global title standard, possible values are:

01 ITU-T 02 ANSI

4 global title indicator in the global title of an SCCP message. The global title indicator is interpreted in following manner when the value in the third supplementary field is 01 (ITU-T):

01 global title contains only the nature of address indicator 02 global title contains only the translation type 03 global title contains the translation type, the numbering plan and the encoding scheme 04 global title contains the translation type, the numbering plan, the encoding scheme and the nature of address indicator 05-15 global title does not contain the translation type, the numbering plan, the encoding scheme or the nature of address indicator. These global title indicator values have not been defined in the ITU-T recommendations

The global title indicator is interpreted in following manner when the value in the third supplementary field is 02 (ANSI):

01 global title contains the translation type, the numbering plan and the encoding scheme 02 global title contains only the translation type 03-15 global title does not contain the translation type, the numbering plan, the encoding scheme or the nature of address indicator. These global title indicator values have not been defined in the ANSI recommendations

5 translation type from the global title of the SCCP message. The translation type is interpreted in the following manner when the value in the third supplementary field is 01 (ITU-T):

00 translation type not in use FF global title does not include translation type

In the national specification ANSI T1.112-1992 there are values defined for the translation type with the third supplementary field value 02 (ANSI) and with the fourth supplementary field value 02. These values of the translation

Page 130: Descrption alarms - GSM NOKIA - 1000 à 1999

130 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1241 SCCP GLOBAL TITLE TRANSLATION ANALY-SIS FILE ERROR

type can be analysed in the normal way, but they do not cause special procedures in the system

6 numbering plan and encoding scheme from the global title of the SCCP message. The encoding scheme is encoded with the least meaningful bits 1-4 in the following manner:

0000 unknown 0001 BCD, odd number of digits 0010 BCD, even number of digits 0011 reserved for future use : 1110 reserved for future use 1111 encoding scheme not included in global title

The numbering plan is encoded with the most meaningful bits 5-8 in the following manner:

0000 unknown 0001 ISDN/telephone network numbering plan (E.164,E.163) 0010 reserved for future use 0011 data network numbering plan (X.121) 0100 telex network numbering plan (F.69) 0101 ship telephone network numbering plan (E.210,E.211) 0110 mobile telephone network numbering plan (E.212) 0111 ISDN/mobile telephone network numbering plan (E.214) 1000 reserved for future use : 1110 reserved for future use 1111 numbering plan not included in global title

7 nature of address indicator from the global title of the SCCP message. Possible values are:

01 subscriber number 02 reserved for national use 03 national meaningful number 04 international number 05 reserved for future use : FE reserved for future use FF nature of address indicator not included in global title

8-15 address information from the global title of the SCCP message so that, for example, the number 12345 is encoded 12 34 5F FF ...

Instructions1. Check whether there should be a global title analysis created for the global title indicated in the disturbance. You can check the

Page 131: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 131

Disturbance Printouts (1000-1999) 1241 SCCP GLOBAL TITLE TRANSLATION ANALY-SIS FILE ERROR

Id:0900d805806a941aConfidential

existing analyses with the NBI command of the Global Title Analysis Handling MML (GTAHAN). Note that in the MML command the given root parameters must be the same as in the alarm.

2. If there is no analysis, you can create it with the MML command NBC, if necessary. Before creating the analysis, find out the correct analysis result to which the new analysis will be connected. You can check the analysis result records with the MML command NAI. If a suitable result record is not found, you can create it with the MML command NAC.

3. If the analysis has already been created, the error may be a file error. It may be possible to correct the error by loading the GANFIL file from disk with the MML command DFM in the unit that set the alarm.

4. As in the short message service the subscriber gives the title, a wrong title can cause the alarm in question. If there is a disturbingly high number of alarms in a situation like this, this alarm can be blocked with the MML command ABB. Note that if the alarm is blocked, it will not be set in the genuine fault situation either.

5. If these actions do not help, fill in a Problem report and send it to your local Nokia Siemens Networks representative.

CancellingNo cancelling.

Page 132: Descrption alarms - GSM NOKIA - 1000 à 1999

132 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1242 SCCP GLOBAL TITLE TRANSLATION RESULT FILE ERROR

84 1242 SCCP GLOBAL TITLE TRANSLATION RESULT FILE ERRORMeaning

Report on the output disturbances of the SCCP global titletranslation. The results output record of the global title translationcontains incorrect information or global title modification cannot bedone to the existing global title number. The alarm may have an effectto the traffic capacity of the system. A message that contains theglobal title in question will not get to its destination.

Supplementary information fields1 error code. Possible values are:

01 record number formed as a result of global title translation causes a file access error when trying to form an address to the Global Title Translation Result File (GTRFIL)

02 translation of global title contains an unknown destination point code

03 translation of global title contains an unknown subsystem number

04 translation of global title contains a reference to a record of the Global Title Modification File (GTMFIL). When modifying the global title using the values of this record, the result is an erroneous global title (e.g. too many digits are added or removed)

2 record number of GTRFIL

3 global title standard, possible values are:

01 ITU-T 02 ANSI

4 global title indicator in the global title of an SCCP message. The global title indicator is interpreted in following manner when the value in the third supplementary field is 01 (ITU-T):

01 global title contains only the nature of address indicator 02 global title contains only the translation type 03 global title contains the translation type, the numbering plan and the encoding scheme 04 global title contains the translation type, the numbering plan, the encoding scheme and the nature of address indicator

Page 133: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 133

Disturbance Printouts (1000-1999) 1242 SCCP GLOBAL TITLE TRANSLATION RESULTFILE ERROR

Id:0900d805806a941aConfidential

05-15 global title does not contain the translation type, the numbering plan, the encoding scheme or the nature of address indicator. These global title indicator values have not been defined in the ITU-T recommendations

The global title indicator is interpreted in following manner when the value in the third supplementary field is 02 (ANSI):

01 global title contains the translation type, the numbering plan and the encoding scheme 02 global title contains only the translation type 03-15 global title does not contain the translation type, the numbering plan, the encoding scheme or the nature of the address indicator. These global title indicator values have not been defined in the ANSI recommendations

5 translation type from the global title of the SCCP message. The translation type is interpreted in the following manner when the value in the third supplementary field is 01 (ITU-T):

00 translation type not in use FF global title does not include translation type

In the national specification ANSI T1.112-1992 there are values defined for the translation type with the third supplementary field value 02 (ANSI) and with the fourth supplementary field value 02. These values of the translation type can be analysed in the normal way, but they do not cause special procedures in the system

6 numbering plan and encoding scheme from the global title of the SCCP message. The encoding scheme is encoded with the least meaningful bits 1-4 in the following manner:

0000 unknown 0001 BCD, odd number of digits 0010 BCD, even number of digits 0011 reserved for future use : 1110 reserved for future use 1111 encoding scheme not included in global title

The numbering plan is encoded with the most meaningful bits 5-8 in the following manner:

0000 unknown 0001 ISDN/telephone network numbering plan (E.164,E.163) 0010 reserved for future use 0011 data network numbering plan (X.121)

Page 134: Descrption alarms - GSM NOKIA - 1000 à 1999

134 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1242 SCCP GLOBAL TITLE TRANSLATION RESULT FILE ERROR

0100 telex network numbering plan (F.69) 0101 ship telephone network numbering plan (E.210,E.211) 0110 mobile telephone network numbering plan (E.212) 0111 ISDN/mobile telephone network numbering plan (E.214) 1000 reserved for future use : 1110 reserved for future use 1111 numbering plan not included in global title

7 nature of address indicator from the global title of the SCCP message. Possible values are:

01 subscriber number 02 reserved for national use 03 national meaningful number 04 international number 05 reserved for future use : FE reserved for future use FF nature of address indicator not included in global title

8-15 address information from the global title of the SCCP message so that, for example, the number 12345 is encoded 12 34 5F FF ...

Instructions1. If the value of the first supplementary field is 01, use the NBI command of the Global Title Analysis Handling MML (GTAHAN) to check to which result the analysis in question should lead. You may be able to correct the error by loading the GANFIL and GAIFIL files from disk with the MML command DFM to the unit that set the alarm. If the alarm is set only in one computer unit, a unit restart or switchover may correct the situation. If loading the files does not help, remove the analysis in question and the result with the MML commands NBD and NAD. Then recreate them with the MML commands NAC and NBC. Note that removing the result may cause an outage in the traffic.

2. If the value of the first supplementary field is 02, the disturbance may be caused by a file error. It may be possible to correct the error by loading the GTRFIL file from disk with the MML command DFM to the unit that set the alarm. If loading the file does not correct the situation, find out to which signalling point the analysis in question should lead and use the MML command NAM to correct the signalling point code.

3. If the value of the first supplementary field is 03, the disturbance may be caused by a file error. It may be possible to correct the error by loading the GTRFIL file from disk with

Page 135: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 135

Disturbance Printouts (1000-1999) 1242 SCCP GLOBAL TITLE TRANSLATION RESULTFILE ERROR

Id:0900d805806a941aConfidential

the MML command DFM to the unit that set the alarm. If loading the file does not correct the situation, find out which subsystem should be in the result and correct it with the MML command NAM.

4. If the value of the first supplementary field is 04, use the commands NAI and NAX of the Global Title Result Handling MML (GREHAN) to check the global title information and, if necessary, make corrections with the NAM and NAS commands.

CancellingNo cancelling.

Page 136: Descrption alarms - GSM NOKIA - 1000 à 1999

136 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1244 RUNNING OUT OF MESSAGE BUFFERS

85 1244 RUNNING OUT OF MESSAGE BUFFERSMeaning

The amount of free message buffer memory in one message size class inthe computer is below the alarm limit used in supervision. The alarmlimit is usually set so low that the alarm indicates a criticalreduction in the amount of free message buffers.

When there are no free message buffers, reservation of a message failsand this may disturb the functioning of the computer.

This alarm does not necessarily mean a fault. The alarm can also bean indication of a temporary shortage of free message buffers causedby a high processor load.

Supplementary information fields1 size of message buffers in the message size class which is running out of message buffers

2 number of messages allocated in the message size class

3 number of free messages in the message size class

InstructionsThe reduction in the number of free message buffers may result from asoftware fault or from an insufficient number of free message buffersin the computer as opposed to the software build.The latter one means a wrong dimensioning of the parameters.

As a precautionary act it is advisable to collect some information incase the computer goes to a faulty state or gets restarted.If the situation recurs, it is recommended to inform your local NokiaSiemens Networks representative on the message usage data inorder to find out the nature and cause of the situation. In thiscase, please attach the printouts of the commands mentioned below.

To get the message buffer usage information, start a telnet session forthe computer that is given as the object unit of the alarm, or givethe dmxshow command on the console of the computer.A remote session to the computer (established with the service terminalcommand ZRS or with the MML command ZDDS) should be avoided, because ituses messages and it could even worsen the situation.

1. To get the information on the usage of message buffers, give the service terminal commands

dmxshow -s and

Page 137: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 137

Disturbance Printouts (1000-1999) 1244 RUNNING OUT OF MESSAGE BUFFERS

Id:0900d805806a941aConfidential

dmxshow -m

Command dmxshow -a or dmxshow -A should not be used because it heavily consumes the resources of the computer.

2. To display the computer log, give the service terminal command

clog -s -a

3. To display alarm history of the current date concerning the computer, give the MML command

ZAHP:<unit_type>,<unit_index>;

CancellingNo cancelling.

Page 138: Descrption alarms - GSM NOKIA - 1000 à 1999

138 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1249 DATABASE DISK COPY HAS EXCEEDED MAX-IMUM ALLOWED AGE

86 1249 DATABASE DISK COPY HAS EXCEEDED MAXIMUM ALLOWED AGEMeaning

Database dumping has not been successful for a long time due toa high transaction load and the age of the disk copy has reachedits maximum limit. The dumping is now started with an option toprevent transactions when overloading occurs. This strategy isfollowed until the dumping is completed successfully.

Supplementary information fields1 database index; this is still required in some database applications even though the current trend is that the database is identified by the values entered in the two following supplementary information fields, i.e. database name and database occurrence

2 database name

3 number of database occurrence

4 how much late the disk copy is from the state in memory. The format of the value is hh:mm

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 139: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 139

Disturbance Printouts (1000-1999) 1250 DATA LINK LAYER PROTOCOL MISMATCH

Id:0900d805806a941aConfidential

87 1250 DATA LINK LAYER PROTOCOL MISMATCHMeaning

The second layer protocol (LAPD) of the D-channel of the primary rateaccess has detected protocol errors. The cause may be a malfunction inthe unit or the equipment functioning as the terminal equipment, or afaulty connection (loop) in the switching network or at some other pointof the PCM connection.

Supplementary information fields1 number of the channel link set (D-channel)

2 D-channel index within the channel link set:

00 primary channel 01 back-up channel (in primary rate access only, not in use)

3 type of the channel link set:

00 primary rate access channel link set 01 subscriber module (SUB) channel link set 02 exchange terminal (ET) channel link set 03 functional unit channel link set

4 number of the D-channel's PCM

InstructionsThe alarm usually appears when the transmitting directionin the data link connection is connected to the receiving directionwithin the network element or outside it.

The network element may also have been configured so that it isfunctioning as the incorrect end of the connection from the point ofview of the LAPD protocol. Also, the LAPD protocol itself maybe faulty.

The instantaneous values of the counters that set the alarm canbe examined in real time, see instructions on LAPD statistics.The incrementing of the counter RECEIPT OF NON-IMPLEMENTED FRAMEindicates a loop or incorrect configuration in the opposing end,RECEIPT OF UNSOLICITED UA, RECEIPT OF FRAME WITH WRONG SIZE andN201 ERROR indicate a malfunction in the opposing end.

CancellingNo cancelling.

Page 140: Descrption alarms - GSM NOKIA - 1000 à 1999

140 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1251 EXCESSIVE RETRANSMISSIONS ON DATA LINK CONNECTION

88 1251 EXCESSIVE RETRANSMISSIONS ON DATA LINK CONNECTIONMeaning

The second layer of the primary rate access D-channel does notreceive any answers to the command frames it has sent. The missinganswers may be due to a partial or total inoperation of the remote end,or breaks in the data link connection.

The alarm usually appears in connection with short-term or permanentbreaks in the data link connection. The alarm may also indicate problemswith protocol in the data link connection layer. In other words, theremote end does not, in some situations, respond according to therecommendations.

Supplementary information fields1 number of the channel link set (D-channel)

2 D-channel index within the channel link set:

00 primary channel 01 backup channel (in primary rate access only, not in use)

3 type of the channel link set:

00 primary rate access channel link set 01 subscriber module (SUB) channel link set 02 exchange terminal (ET) channel link set 03 functional unit channel link set

4 number of the D-channel's PCM

InstructionsThe fault disturbing the D-channel may lie in the hardware of thenetwork elements, more probably, however, in the data link connectionor the synchronization between the network elements.

The working order of the data link connection can be monitoredwith an MML command, see instructions on PCM statistics.Synchronization may be handled with MML commands, see instructions onsynchronization.In addition to possible breaks and external disturbances, it isespecially important to check in the data link connection, thatthe PCM circuit signals and the protective sheath are connectedcorrectly in the connection points (ET, distribution frames).

The instantaneous values of the counters UNSUCCESSFUL RETRANSMISSION OFSABME and RR/RNR/REJ which cause the alarm may be monitored in real

Page 141: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 141

Disturbance Printouts (1000-1999) 1251 EXCESSIVE RETRANSMISSIONS ON DATALINK CONNECTION

Id:0900d805806a941aConfidential

time, see instructions on LAPD statistics.The RR frame's failure to answer indicates breaks of data linklayer lasting a few seconds, while the SABME frame's failure to answerindicates a break longer than that.

CancellingNo cancelling.

Page 142: Descrption alarms - GSM NOKIA - 1000 à 1999

142 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1252 EXCESSIVE ERROR RATE ON DATA LINK CONNECTION

89 1252 EXCESSIVE ERROR RATE ON DATA LINK CONNECTIONMeaning

There are transmission errors in the data link connection of theprimary rate access D-channel. The errors manifest themselves incheck sum errors of the second layer frames, and/or in overlongframes due to the disappearance of frame signals.

Supplementary information fields1 number of the channel link set (D-channel)

2 D-channel index within the channel link set:

00 primary channel 01 backup channel (in primary rate access only, not in use)

3 type of the channel link set:

00 primary rate access channel link set 01 subscriber module (SUB) channel link set 02 exchange terminal (ET) channel link set 03 functional unit channel link set

4 number of the D-channel's PCM

InstructionsThe fault disturbing the D-channel may lie in the hardware of thenetwork elements, more probably, however, in the data link connectionor the synchronization between the network elements.

The working order of the data link connection can be monitoredwith an MML command, see instructions on PCM Statistics.Synchronization may be handled with MML commands, see instructionson Synchronization. In addition to possible breaks and externaldisturbances, it is especially important to check in the data linkconnection, that the PCM circuit signals and the protective sheathare connected correctly in the connection points(ET, distribution frames).

The instantaneous values of the counter CRC ERRORS (check sum error)which causes the alarm may be monitored in realtime, see instructions on LAPD Statistics.

CancellingNo cancelling.

Page 143: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 143

Disturbance Printouts (1000-1999) 1253 NO RESPONSE FROM PRIMARY RATE AC-CESS TERMINAL

Id:0900d805806a941aConfidential

90 1253 NO RESPONSE FROM PRIMARY RATE ACCESS TERMINALMeaning

The primary rate access terminal has not answered to the inquiries orrequests sent to it.

Supplementary information fields1 index of the primary rate access terminal

2 channel link set number

3 D-channel index within the channel link set

4 type of the channel link set:

00 primary rate access channel link set 01 subscriber module (SUB) channel link set 02 exchange terminal (ET) channel link set 03 functional unit channel link set

5 message that was expected or a message to which response was expected

6 internal state of D-channel

7 identifier of D-channel time supervision

InstructionsIf the situation keeps occurring, check the existence and conditionof the primary rate access terminal.

CancellingNo cancelling.

Page 144: Descrption alarms - GSM NOKIA - 1000 à 1999

144 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1254 UNSOLICITED DATA LINK RE-ESTABLISH-MENT

91 1254 UNSOLICITED DATA LINK RE-ESTAB-LISHMENTMeaning

A connection has been re-established on the D-channel, during whichsome information may have been lost. The alarm usually occurs inconnection with unit restarts, but it can also occur in datatransmission connections of poor quality.

Supplementary information fields1 number of the channel link set (D-channel)

2 D-channel index within the channel link set:

00 primary channel 01 backup channel (in primary rate access only, not in use)

3 type of the channel link set:

00 primary rate access channel link set 01 subscriber module (SUB) channel link set 02 exchange terminal (ET) channel link set 03 functional unit channel link set

4 number of the D-channel's PCM

InstructionsThe alarm requires no actions. If the alarm keeps recurring, check thequality of the connection, and the condition of the equipment.

CancellingNo cancelling.

Page 145: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 145

Disturbance Printouts (1000-1999) 1255 PRIMARY RATE ACCESS MESSAGE DISTRI-BUTION ERROR

Id:0900d805806a941aConfidential

92 1255 PRIMARY RATE ACCESS MESSAGE DISTRIBUTION ERRORMeaning

The PXRECE has received a message which it cannot distribute tothe receiver.

Supplementary information fields1 error code 1d erroneous protocol discriminator. You can check its meaning in General Error Messages of System

2 number of the primary rate access terminal

3 indicates the protocol discriminator of the message received

4-9 indicates the next six fields of the message

InstructionsThere is an erroneous protocol discriminator in the message received.The operation of the counterpart must be checked. See also the logprintouts of the PXRECE. The log contains the heading of the erroneousmessage.

CancellingNo cancelling.

Page 146: Descrption alarms - GSM NOKIA - 1000 à 1999

146 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1256 INCORRECT PRD MESSAGE FROM PRIMARY RATE ACCESS TERMINAL

93 1256 INCORRECT PRD MESSAGE FROM PRIMARY RATE ACCESS TERMINALMeaning

An incorrect message has been received from the primary rate accessterminal. This may be due to a fault or disturbance in the terminalitself, or to the incorrect contents of the message sent by theremote end.

Supplementary information fields1 an error has been detected in the message 1d the message is too long You can check the meaning of other error codes in General Error Messages of System

2 number of the primary rate access terminal

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 147: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 147

Disturbance Printouts (1000-1999) 1260 X.25/ETHERNET DATA TERMINAL SPONTA-NEOUS RESTART

Id:0900d805806a941aConfidential

94 1260 X.25/ETHERNET DATA TERMINAL SPONTANEOUS RESTARTMeaning

The AC25-S/AC25-A/AS7-U/AS7-V/AS7-A/COCEN plug-in unit has restarted.As a result of the restart of the plug-in unit AC25-S/AS7-U, the OSIadministration releases all X.25 connections via that plug-in unit.The plug-in unit is reinitialized after the connections have beenreleased.

The restart of the COCEN plug-in unit does not result in the releaseof OSI or TCP/IP connections via that plug-in unit, but the levelof service is temporarily decreased.

Supplementary information fields1 the index of the reinitialized plug-in unit

InstructionsIf this alarm is preceded by a notice informing that thecomputer unit hosting the plug-in unit has restarted, thenthere is no error. When this alarm is received, the possibleeffects of the restart on the OSI connections should be checked.

CancellingNo cancelling.

Page 148: Descrption alarms - GSM NOKIA - 1000 à 1999

148 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1261 OSI CHANNEL GROUP UNREACHABLE

95 1261 OSI CHANNEL GROUP UNREACHABLEMeaning

The channel group becomes unavailable and this means that remoteapplications all of whose labels use unavailable channel groupsbecome unreachable. The channel group becoming unavailable is causedby the fact that the group contains no available channels.

Supplementary information fields1 the name of the channel group that has become unavailable

InstructionsNormally, when a channel group has become unavailable it is becauseplug-in units have been restarted, and no error is involved. Theavailability of a channel group can be checked, when necessary, bymeans of the QGI MML command and its GROUP STATE column. The valueUA means an unavailable channel group, and AV an available one.

CancellingNo cancelling.

Page 149: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 149

Disturbance Printouts (1000-1999) 1262 OSI SERVICE PROVIDER RESET

Id:0900d805806a941aConfidential

96 1262 OSI SERVICE PROVIDER RESETMeaning

An OSI program block restart is caused by an internal faultsituation, e.g. when the memory space allocated to the programblock has been exceeded.The disconnection of the OSI connections maintained by theprogram block results in the program block being restarted.The memory allocation situation of the program block priorto the restart is written into the log of the unit where thecentralised part of the OSI administration is located.

Supplementary information fields1 the family identifier indicates which program block has been restarted. Possible values are 0000 - FFFF

2 the diagnostics field indicates the reason why the program block is restarted. Possible values are:

01 : memory space request too large 02 : memory space exceeded 03 : erroneous interface table 04 : ASN.1 decoding error

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 150: Descrption alarms - GSM NOKIA - 1000 à 1999

150 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1263 OSI SERVICE PROVIDER INTERFACE ERROR

97 1263 OSI SERVICE PROVIDER INTERFACE ERRORMeaning

An OSI program block has received a message that has not been specifiedin its interface. The sender of the message is written into the log ofthe unit that accomodates the centralized part of the OSI administration.

Supplementary information fields1 identifies the program block in question. Possible values are 0000 - FFFF

2 the interface field identifies the interface where the fault occurred. Possible values are

00 : administration interface 01 : upper interface 02 : lower interface

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 151: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 151

Disturbance Printouts (1000-1999) 1264 OSI INCOMING CALL DENIED

Id:0900d805806a941aConfidential

98 1264 OSI INCOMING CALL DENIEDMeaning

A call has been received from the network to a local application withincoming call denial.

Supplementary information fields1 the first part (max. 7 digits) of the address of the calling remote end

2 the remaining part (8 digits) of the address of the calling remote end

3 number of digits in the address of the calling remote end. The value is between 0x00 and 0x0F

4 OADFIL file record containing the called local address

5 plug-in unit from where the call arrived

InstructionsIf several disturbance notices are received, check the filesrelated to the coding of the address fields of the message, atboth ends of the trunk circuit.

CancellingNo cancelling.

Page 152: Descrption alarms - GSM NOKIA - 1000 à 1999

152 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1273 ASP ACTIVATION FAILED

99 1273 ASP ACTIVATION FAILEDMeaning

The activation of the ASP (Application Server Process) orSGP (Signalling Gateway Process) has not succeeded. The alarm is forASP if the network element is working as a Signalling Gateway or forSGP if the network element is working as an Application Server.The ASP/SGP is activated by the exchange of ASPSM (ASP StateMaintenance), RKM (Routing Key Management) and ASPTM (ASP TrafficMaintenance) messages between the two M3UA endpoints. So when this alarmis set by the S3CMAN (SCTP association manager) program block, somethinghas probably gone wrong during that ASP message exchanging. The 2nd and3rd supplementary information fields show the ASP message at which theASP activation failed. Other reason for the alarm is the insufficientresources, such as, an insufficient amount of records in work fileswhich prevents a new ASP to be activated. If none of the ASPs in thespecified association set in the 4th supplementary information fieldbecome active, it means that the whole Application Server or SignallingGateway is not available to this network element. Otherwise the signaltransmission capacity may only be somewhat decreased.

Supplementary information fields1 type of the ASP activation failure. Possible values are:

01 Unsupported M3UA version in M3UA message header 02 M3UA draft version used in message differs from configured 03 The traffic handling mode in M3UA message does not match with the configured one 04 The routing context value in M3UA message does not match with the stored one 05 No matching configured routing key was found for the routing key found in REGREQ message. 06 An unsupported parameter was found inside the routing key parameter in REGREQ message. 07 Registration status in REGRSP is not 0 08 The local routing key identifier in REGRSP differs from that one that was sent in REGREQ 09 There is no space for the new ASP in SGWFIL file 0A There is no space for the new ASP in S3WORK file 0B A mandatory parameter is missing in M3UA message 0C A M3UA message is received that is not in accordance with the role specified in the association set, shown by ZOYI MML command, such as, the receiving of ASPUP, ASPAC, REGREQ at the ASP even if only the SG is prepared to receive them. 0D A communication up notification was received at the server side with unconfigured IP address or the unit from which the communication up was received is not the configured unit shown by ZOYI MML command 0E ASPAC (ASP Active) message was received for the ASP in wrong

Page 153: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 153

Disturbance Printouts (1000-1999) 1273 ASP ACTIVATION FAILED

Id:0900d805806a941aConfidential

state, i.e., for ASP the state of which is not inactive. 0F The outbound stream count in the communication up notification is less than was ordered in the associate primitive

2 message class of M3UA message. Possible values are:

03 ASP State Maintenance (ASPSM) messages 04 ASP Traffic Maintenance (ASPTM) Messages 09 Routing Key Management (RKM) Messages

3 message type of M3UA message. Possible values are dependent on the preceding supplementary information field:

When the 2nd supplementary information field is 03, the possible values are:

01 ASP Up (ASPUP) 04 ASP Up Acknowledgement (ASPUP ACK)

When 2nd supplementary information field is 04, the possible values are:

01 ASP Active (ASPAC) 03 ASP Active Acknowledgement (ASPAC ACK)

When 2nd supplementary information field is 09, the possible values are:

01 Registration Request (REG REG) 02 Registration Response (REG RSP)

4 association set to which the ASP belongs, 0FFFF if not known

5 when an inconsistent parameter value is included in the M3UA message, this supplementary information field shows that inconsistent parameter value. The parameter, which has the inconsistent value is deduced from the value of the 1st supplementary information field: 01 means m3ua version, 02 means m3ua draft version, 03 means traffic handling mode, 04 means routing context. Value 0FFFFFFFF means that this field is not applicable for the alarm.

6 the value of the parameter, with which the preceding information field is inconsistent. In practice this field shows the value that is configured and shown also by the ZOYI MML command. Value 0FFFFFFFF means that this field is not applicable for the alarm.

7 the parameter tag of the missing parameter. Possible values are:

Page 154: Descrption alarms - GSM NOKIA - 1000 à 1999

154 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1273 ASP ACTIVATION FAILED

06 Routing Context 0207 Routing Key 020A Local_Routing Key Identifier 020B Destination Point Code 0200 Network Appearance 0208 Registration Result 0212 Registration Status 0FFFF There is no missing parameter, i.e., the field is not applicable with the alarm

8 the identifier that unambiguously identifies the ASP, the value shows the SGWFIL record number.

InstructionsIf the value of the 1st supplementary information field is 01:

The peer M3UA is using M3UA RFC version that is newer than supported. Check whether it is possible to configure the peer M3UA to use the supported version. The version that the peer M3UA is using is specified by the 5th supplementary information field. The version that is supported is specified by the 6th supplementary information field.

If the value of the 1st supplementary information field is 02:

The peer M3UA is using M3UA draft version, which is different than the one configured at this network element in the association set specified in the 4th supplementary information field. The configured M3UA draft version is also specified in the 6th supplementary information field, possible values are 07 or 09. The M3UA draft version that the peer M3UA is using is specified in the 5th supplementary information field. The M3UA message, in which the M3UA draft version was found is specified in the 2nd and 3rd supplementary fields. If the configured M3UA draft version needs to be modified in this network element, use ZOYM MML command and give the association set and the M3UA draft version as the parameters.

If the value of the 1st supplementary information field is 03:

The traffic handling mode value that is included in the M3UA message is different from the one that is configured in the association set specified in the 4th supplementary information field. The configured traffic handling mode value is also specified in the 6th supplementary information field. The value of the traffic handling mode included in the M3UA message is specified by the 5th supplementary information field. The M3UA message, in which the traffic handling mode was included is specified in the 2nd and 3rd supplementary fields. Check which traffic-handling mode is correct and change the configuration at either this network element or at the peer M3UA. If the value needs to be modified at

Page 155: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 155

Disturbance Printouts (1000-1999) 1273 ASP ACTIVATION FAILED

Id:0900d805806a941aConfidential

this network element, use the ZOYM MML command and give the association set and the correct traffic handling mode as the parameters.

If the value of the 1st supplementary information field is 04:

The routing context value that is included in the M3UA message differs from the one stored at this network element and was determined automatically by this network element during the routing key registration, i.e., when handling the REGREQ message. It is also possible that there is no routing context value stored in this network element, which means that the routing key registration was not done. The routing context value stored at this network element is specified in the 6th supplementary information field. The value of the routing context included in the M3UA message is specified in the 5th supplementary information field. The M3UA message, in which the routing context was included is specified in the 2nd and 3rd supplementary fields. Try to find out why the peer M3UA does not use the correct routing context value, or if the routing context is not stored at this network element (the 6th supplementary information field is 0FFFFFFFF)and if it is possible to configure the peer M3UA so that the routing context parameter is not used in the message. If that peer M3UA is operating in the Nokia Siemens Networks network element, fill in a Problem Report and send it to your local Nokia Siemens Networks representative. In the problem report include this alarm And printouts of following MML commands ("CM,0" in the following commands refer to active central memory): 1) ZOYI::A; 2) ZDFD:CM,0:A79,,N,; 3) ZDFD:CM,0:AF3,,N,;

If the value of the 1st supplementary information field is 05:

No matching configured routing key was found for the routing key found in REGREQ message. The routing key here refers to the network appearance and the destination point code (DPC). The network appearance value included in REGREQ message is specified in the 5th supplementary information field and the DPC included in REGREQ message is specified in the 6th supplementary information field. Check that the network appearance value is correct in the association set where the ASP is about to be added by the routing key registration procedure. If the value needs to be modified at this network element, use ZOYM MML command and give the association set and the correct network appearance value as the parameters. If the network appearance value is correct, check that the M3UA based link set is configured to the right signalling point at this network element. If not you have to delete the signalling link set and route set and then recreate them so that the signalling point code is correct.

Page 156: Descrption alarms - GSM NOKIA - 1000 à 1999

156 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1273 ASP ACTIVATION FAILED

If the value of the 1st supplementary information field is 06:

The peer M3UA is using an unsupported parameter inside the routing key parameter of REGREQ message. Only network appearance and destination point code are supported parameters inside a routing key. The unsupported parameter tag inside the routing key parameter is specified in the 5th supplementary information field and the value of that unsupported parameter in the 6th supplementary information field. Check whether it is possible to configure the peer M3UA to use only network appearance and DPC as a routing key. If not do not use routing key registration at both ends if possible, and at this network element modify the registration_request parameter to value "NO" in the association set, in which the ASP is about to be added by the routing key registration procedure as follows: 1) Change the state of the corresponding M3UA based link to UA-INU, with ZNLC MML command. 2) Change the registration_request parameter giving the association set and the new value for registration_request parameter as the parameters in ZOYM MML command. 3) Change the state of the corresponding M3UA based link to AV-EX, with ZNLC MML command. If the routing key registration is turned off, you have to add the ASPs in the corresponding association set (the role of the association set is server) by giving the destination IP addresses of the ASPs.

If the value of the 1st supplementary information field is 07:

The peer M3UA does not answer with success status to the routing key registration request sent by this network element. The status value that is returned by the peer M3UA is specified by the 5th supplementary information field.

When the 5th supplementary information field is 03 (invalid network appearance):

Check that the network appearance value configured in the association set specified by the 4th supplementary information field is correct. If the value needs to be modified at this network element, use ZOYM MML command and give the association set and the correct network appearance value as the parameters to the ZOYM MML command.

When the 5th supplementary information field is 02 (invalid DPC) or 04 (invalid routing key):

Check whether the peer M3UA supports network appearance and DPC as a routing key. If so check that the network appearance value configured in the association set specified by the 4th supplementary information field is correct. If the value needs to be modified at this network element, use ZOYM MML

Page 157: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 157

Disturbance Printouts (1000-1999) 1273 ASP ACTIVATION FAILED

Id:0900d805806a941aConfidential

command and give the association set and the correct network appearance value as the parameters to the ZOYM MML command. If the peer M3UA does not currently support network appearance and DPC as a routing key, check whether it is possible to configure the peer M3UA as such. If not, do not use routing key registration at both ends if possible, and at this network element modify the registration_request parameter to value "NO", as follows: 1) Change the state of the corresponding M3UA based link to UA-INU, with ZNLC MML command. 2) Change the registration_request parameter giving the

associationset specified in the 4th supplementary information field and the new value for registration_request parameter as the parameters in ZOYM MML command. 3) Change the state of the corresponding M3UA based link to AV-EX, with ZNLC MML command.

When the 5th supplementary information field is 01 (error-unknown), 05 (permission denied), 06 (cannot support unique routing), 07 (routing key not currently provisioned), 08 (insufficient resources):

Do not use routing key registration at both ends if possible, and at this network element modify the registration_request parameter to value "NO", as follows: 1) Change the state of the corresponding M3UA based link to UA-INU, with ZNLC MML command. 2) Change the registration_request parameter giving the association set specified in the 4th supplementary information field and the new value for registration_request parameter as the parameters in ZOYM MML command. 3) Change the state of the corresponding M3UA based link to AV-EX, with ZNLC MML command.

When the 5th supplementary information field is 09 (unsupported RK parameter field):

Check whether the peer M3UA supports network appearance and DPC as a routing key. If the peer M3UA does not currently support network appearance and DPC as a routing key, check if it is possible to configure the peer M3UA such.

Page 158: Descrption alarms - GSM NOKIA - 1000 à 1999

158 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1273 ASP ACTIVATION FAILED

If not, do not use routing key registration at both ends if possible, and in this network element modify the registration_request parameter to value "NO", as follows: 1) Change the state of the corresponding M3UA based link to UA-INU, with ZNLC MML command. 2) Change the registration_request parameter giving the association set specified in the 4th supplementary information field and the new value for registration_request parameter as the parameters in ZOYM MML command. 3) Change the state of the corresponding M3UA based link to AV-EX, with ZNLC MML command.

When the 5th supplementary information field is 0A (unsupported/ invalid Traffic handling mode):

Check that the value of the traffic handling mode configured at this network element in the association set specified by the 4th supplementary information field is correct. If the value needs to be modified at this network element, use the ZOYM MML command and give the association set and the correct traffic handling mode value as the parameters to the ZOYM MML command.

If the value of the 1st supplementary information field is 08:

The local routing key identifier value in the received REGRSP was not the same as it was in the REGREQ sent by this network element (REGRSP is a response message to REGREQ message). The local RK-identifier value that was included in the REGREQ is specified by the 5th supplementary information field and the local RK-identifier value that was included in the REGRSP is specified by the 6th supplementary information field. Try to find out why the peer M3UA does not answer with the correct local RK-identifier value in the REGRSP. If the peer M3UA is operating in the Nokia Siemens Networks network element, fill in a Problem Report and send it to your local Nokia Siemens Networks representative. In the problem report include this alarm and printouts of following MML commands ("CM,0" in the following commands refers to active central memory): 1) ZOYI::A; 2) ZDFD:CM,0:A79,,N,; 3) ZDFD:CM,0:AF3,,N,;

If the value of the 1st supplementary information field is 09 or 0A:

Fill in a Problem Report and send it to your local Nokia Siemens Networks representative. In the problem report include this alarm and printouts of following MML commands ("CM,0" in the following commands refer to active central memory): 1) ZOYI::A; 2) ZDFD:CM,0:A79,,N,;

Page 159: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 159

Disturbance Printouts (1000-1999) 1273 ASP ACTIVATION FAILED

Id:0900d805806a941aConfidential

3) ZDFD:CM,0:AF3,,N,;

If the value of the 1st supplementary information field is 0B:

A mandatory parameter is missing in a M3UA message. The parameter tag of the missing parameter is specified in the 7th supplementary information field. Try to find out why the peer M3UA does not use that parameter in the M3UA message specified in the 2nd and 3rd supplementary information field. If the peer M3UA is operating in the Nokia Siemens Networks network element, fill in the Problem Report from this network element and send it to your local Nokia Siemens Networks representative. In the problem report include this alarm and printouts of following MML commands ("CM,0" in the following commands refer to active central memory): 1) ZOYI::A; 2) ZDFD:CM,0:A79,,N,; 3) ZDFD:CM,0:AF3,,N,;

If the value of the 1st supplementary information field is 0C:

Check whether the role specified in the 4th supplementary information field is correct. If not, you have to change the role as follows: 1) Change the state of the corresponding M3UA based link to UA-INU, with ZNLC MML command. 2) Change the role parameter giving the association set specified in the 4th supplementary information field and the new value for the role parameter as the parameters in ZOYM MML command. 3) Change the state of the corresponding M3UA based link to AV-EX, with the ZNLC MML command.

If the value of the 1st supplementary information field is 0D:

The 5th supplementary information field shows the log reference. The 6th supplementary information field shows the unit, from which the communication up was received. At the same time as the alarm two logs are written: first with the same log reference as in the alarm, second with the IP address that was not configured. In the second log the first byte shows the IP address version, 0 means IPv4 and 1 means IPv6. Check whether the IP address written to the log should be configured to some association set, which has the role of server. If so, add the IP address to the desired association set with ZOYA MML command.

If the value of the 1st supplementary information field is 0E:

The reason for the alarm may be that the "registration request" parameter has value YES even if it should have value NO. Change the value of the parameter to NO, as follows: 1) Change the state of the corresponding M3UA based link to UA-INU, with the ZNLC MML command. 2) Change the registration_request parameter giving the association

Page 160: Descrption alarms - GSM NOKIA - 1000 à 1999

160 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1273 ASP ACTIVATION FAILED

set specified in the 4th supplementary information field and the new value = NO for registration_request parameter as the parameters in ZOYM MML command. 3) Change the state of the corresponding M3UA based link to AV-EX, with the ZNLC MML command.

If the value of the 1st supplementary information field is 0F:

SCTP could not establish the association with the configured amount of outbound streams. The amount of streams is configured in the association set basis. Use ZOYI::A; command to see the configured amount of streams that is further specified as the sum of parameters "first data stream number" and "data stream count". This SCTP user adjusted to use the lower amount of outbound streams that was returned in the communication up notification. The amount of SCTP streams that are returned in the communication up notification are shown in the 5th supplementary information field. The amount of configured streams is shown in the 6th supplementary information field.

CancellingNo cancelling.

Page 161: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 161

Disturbance Printouts (1000-1999) 1280 INTERNAL COMMUNICATION CHANNEL FAIL-URE

Id:0900d805806a941aConfidential

100 1280 INTERNAL COMMUNICATION CHANNEL FAILUREMeaning

A failure has been detected in the communication between thepreprocessors of the system, or between a preprocessor unit andits host computer. The failure hampers communication.

Supplementary information fields1 type of the preprocessor unit generating the alarm or suspected faulty.

See instructions on Diagnostics and Testing

2 index of the unit generating the alarm or suspected faulty; if .. the index is not known

3 channel identifier within the unit:

SBCN: FFFF host computer 0000 RSCN (SUB 0) VXCN: FFFF host computer 0000 RSCN (SUB 0) RSCN: FFFF host computer 1...7 index of SBCN unit (SUB 1-7) 8 CLxTG-0 (CLSS) or CLET-0 (CLES) 9 CLxTG-1 (CLSS) or CLET-1 (CLES) CLxTG: FFFF host computer or RSCN 0 CLxTG CLET: FFFF RSCN 0 CLET ATMX: FFFF host computer TRCO: FFFF host computer 1...4 index of ET2x HWAT 0 HWAT

4 type of the failure:

01 connection establishment failed 02 connection re-establishment 03 message queue overflow 04 CRC or some other error ratio limit of the frame level has been exceeded 05 protocol error 06 loop test failed 07 error ratio limit of the time supervision has been exceeded FF other failure

Page 162: Descrption alarms - GSM NOKIA - 1000 à 1999

162 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1280 INTERNAL COMMUNICATION CHANNEL FAIL-URE

InstructionsIf the connection establishment fails, check the wirings to the serialcommunication of the unit (clock system, serial communication bus) andthe functioning of the unit of the connection's remote end.

A successful re-establishment of the connection is notified aftera temporary disturbance. Some messages of the applications mayhave disappeared, in which case the operations related to the unitshould be observed.

The overflow of the unit's message queue is caused either by theinability of the data transmission connection to transmit messagesat a speed corresponding to the speed of message requestes(an overload situation in the remote end or disturbances in thedata transmission connection) or by an internal overload in theunit. The consequences are the same as in the re-establishmentof the connection.

If the failure type is "protocol error", check especially thewirings or strappings indicating the unit index of the units,as well as the PCM cabling and possible transmission equipment,including the ET.

If the loop test has failed, you have to check and possiblyreplace the plug-in unit that caused the alarm. The clock system,i.e. the clock units or the cabling, may also be faulty.

CancellingNo cancelling.

Page 163: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 163

Disturbance Printouts (1000-1999) 1282 ASSOCIATION PARAMETER FAILURE

Id:0900d805806a941aConfidential

101 1282 ASSOCIATION PARAMETER FAILUREMeaning

Parameter setting has failed concerning Signalling System No. 7 (SS7)signalling over Internet Protocol (IP).

The MTP3 User Adaptation Layer (M3UA) protocol has failed in setting atleast one of the Stream Control Transmission Protocol (SCTP) parametersin the context of the SCTP association establishment.

This means that the value(s) of the SCTP association parameter(s)do not change and so the value(s) of the parameter(s) are notnecessarily the values that the user has configured. When the parametersetting fails, SCTP operates with the old value of the parameter.

Supplementary information fields1 SCTP Payload Protocol Identifier 1 - IUA RFC3057 2 - M2UA RFC3331 3 - M3UA RFC3332 4 - SUA RFC2960 5 - M2PA RFC2960 6 - V5UA RFC2960 7 - H.248 H.248 8 - BICC/Q.2150.3 Q.1902.1/Q.2150.3 9 - TALI RFC3094 10 - DUA <draft-ietf-sigtran-dua-03.txt> Ong 11 - ASAP <draft-ietf-rserpool-asap-03.txt> Ong 12 - ENRP <draft-ietf-rserpool-enrp-03.txt> Ong 13 - H.323 H.323 14-Q.IPC/Q.2150.3 Q.2631.1/Q.2150.3

2 IUA: association number

M3UA: association set, to which the association belongs

3 IUA: Not applicable

M3UA: index of the association inside the association set. The value is between 0-31

4 identifier of the SCTP association within the computer unit

5 number of the socket corresponding the association

Page 164: Descrption alarms - GSM NOKIA - 1000 à 1999

164 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1282 ASSOCIATION PARAMETER FAILURE

6 status of the socket option setting corresponding the parameters. Value of the field is one of the following values or a combination (sum) of some of the following values.

0001 SCTP Retransmission Timeout parameter setting failed. Corresponding parameter names are RTI.INIT, RTO.MIN and RTO.MAX.

0002 SCTP Peer Address parameter setting failed. Corresponding parameter names are HB.INTERVAL and PATH.MAX.RETRANS.

0004 SCTP Association parameter setting failed. Corresponding parameter name is ASSOCIATION.MAX.RETRANS.

0008 SCTP Checksum algorithm selection parameter setting failed.

0010 SCTP Bundling parameter setting failed.

0020 SCTP SACK parameter setting failed.

InstructionsFill in a Problem Report and send it to your local Nokia SiemensNetworks representative.

Enclose the printout outputs with the MML commands ZOYI::A; andZOYO; in the failure report. The ZOYI command shows the informationof the SCTP associations and ZOYO shows the SCTP association parametervalues. Enclose also the log writings of the S3ZOCK program block in thecomputer log of the signalling unit identified in the first two fields.Computer log writings can be obtained with service terminal commandsZGD and ZGS.

CancellingNo cancelling

Page 165: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 165

Disturbance Printouts (1000-1999) 1293 SCCP GT SCREENING APPLIED

Id:0900d805806a941aConfidential

102 1293 SCCP GT SCREENING APPLIEDMeaning

SCCP has detected at the signalling transfer point a signalling messagefor which this alarm must be set. Additionally, also the transit of thesignalling message is to be prevented.This conclusion is based on the calling and the called globaltitles included in the message.

If the transit message is destroyed, it may cause disturbancein the function of the user parts of the signalling point that sentthe message. Usage restrictions for transit messages are usually seton exchanges that function on another operator's interface.

Supplementary information fields1 type of access right violation of the STP function (cause code)

01 the source point behind the calling GTT result should not send signalling messages with the called GT, the translation of which leads to the called GTT result in question (the message has been transmitted) 02 the source point behind the calling GTT result is not allowed to send signalling messages with the called GT, the translation of which leads to the called GTT result in question (the message has been destroyed or sent back)

2 signalling network of the adjacent point from which the processed signalling message was received. Signalling network can get the following values:

00 international network 0, IN0 04 international network 1, IN1 08 national network 0, NA0 0C national network 1, NA1

3 point code value of the adjacent point from which the processed signalling message was received. This and the 2nd supplementary information field together indicate the signalling point from which the message was received, that is, the linkset from which the message was received.

4 the calling GTT result into which the analysis of the calling GT has led. The calling GTT result and the calling GT analysis that lead to that result can be checked with the MML commands ZODL and ZODJ respectively.

5 the called GTT result into which the analysis of the called GT has led. The called GTT result and the called GT analysis that lead to that result can be checked with the MML commands ZNAI and ZNBI

Page 166: Descrption alarms - GSM NOKIA - 1000 à 1999

166 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1293 SCCP GT SCREENING APPLIED

respectively.

6 the global title standard and the global title indicator used in the calling global title of the SCCP message. The standard is encoded with the most meaningful bits 5-8 in the following manner:

01 ITU-T 02 ANSI

The global title indicator is encoded with the least meaningful bits 1-4. The global title indicator is interpreted in the following manner when the value in the most meaningful bits 5-8 is 01 (ITU-T):

01 global title contains only the nature of address indicator 02 global title contains only the translation type 03 global title contains the translation type, the numbering plan, and the encoding scheme 04 global title contains the translation type, the numbering plan, the encoding scheme, and the nature of address indicator 05-15 global title does not contain the translation type, the numbering plan, the encoding scheme or the nature of address indicator. These global title indicator values have not been defined in the ITU-T recommendations

The global title indicator is interpreted in the following manner when the value in the most meaningful bits 5-8 is 02 (ANSI):

01 global title contains the translation type, the numbering plan and the encoding scheme 02 global title contains only the translation type 03-15 global title does not contain the translation type, the numbering plan, the encoding scheme or the nature of address indicator. These global title indicator values have not been defined in the ANSI recommendations

7 translation type from the global title included in the calling party address of the processed SCCP message. The translation type values 0 and FF are interpreted in the following manner when the value in the least significant bits 1-4 in the sixth supplementary field is 01 (ITU-T):

00 translation type not in use FF global title does not include translation type

For the case the standard is ANSI and the global title indicator is 02, there are values defined for the translation type in the

Page 167: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 167

Disturbance Printouts (1000-1999) 1293 SCCP GT SCREENING APPLIED

Id:0900d805806a941aConfidential

national specification ANSI T1.112-1992. These values of the translation type can be analysed in the normal way, but they do not cause special procedures in the system

8 numbering plan and the four least meaningful bits of the nature of address indicator from the global title included in the calling party address of the processed SCCP message. The numbering plan is encoded with the most meaningful bits 5-8 in the following manner:

0000 unknown 0001 ISDN/telephone network numbering plan (E.164,E.163) 0010 reserved for future use 0011 data network numbering plan (X.121) 0100 telex network numbering plan (F.69) 0101 ship telephone network numbering plan (E.210,E.211) 0110 mobile telephone network numbering plan (E.212) 0111 ISDN/mobile telephone network numbering plan (E.214) 1000 reserved for future use : 1110 reserved for future use 1111 numbering plan not included in global title

The four least meaningful bits of the nature of address indicator is encoded with the least meaningful bits 1-4 in the following manner:

0001 subscriber number 0010 reserved for national use 0011 national meaningful number 0100 international number 0101 reserved for future use : 1110 reserved for future use 1111 nature of address indicator not included in global title

9-11 address information from the global title included in the calling party address of the processed SCCP message so that, for example, the number 12345 is encoded 12 34 5F. If the address information includes more than 6 digits, the address information includes the first 6 digits.

InstructionsSCCP global title screening information says that messages with thecalling global title and the called global title combination in questionshould not be transmitted. The analysis of the calling global title leads

Page 168: Descrption alarms - GSM NOKIA - 1000 à 1999

168 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1293 SCCP GT SCREENING APPLIED

to the calling GTT result as mentioned in the Supplementary informationfield 4. The analysis of the called global title leads to the called GTTresult as mentioned in the Supplementary information field 5.If the value of the Supplementary information field 1 (cause code) was 1,the message was transmitted. If the value of the Supplementaryinformation field 1 (cause code) was 2, the message has been destroyed orsent back. Check if this restriction is justified and remove the blockingwith the MML command ODN if necessary. Otherwise the operator whoowns the signalling point from which the message has been originated,or alternatively the operator who owns the adjacent signalling pointfrom which the message was received, should be notified about an accessright violation.For tracing the operator of the originating signalling point, theinformation supplied in the Supplementary information fields 2, 3, 4, 6,7, 8 and 9 could be used: the Supplementary information fields 2 and 3show the adjacent point from which the message was received;the Supplementary information fields 6, 7, 8 and 9 can be used to getthe calling global title from which the message was originated. TheSupplementary information field 4 (calling GTT result) can also be usedto find out the calling GT via calling GT analysis data, so that thecalling GT analysis is sought using the MML command ZODJ, which leads tothat calling GTT result record.

CancellingNo cancelling.

Page 169: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 169

Disturbance Printouts (1000-1999) 1300 SUPERVISION CONNECTION TO UNIT LOST

Id:0900d805806a941aConfidential

103 1300 SUPERVISION CONNECTION TO UNIT LOSTMeaning

The unit has not responded in the allotted time to a supervisionmessage sent by the supervisory unit. The supervisor has lost theconnection to the unit and waits if the unit has restarted or failed.

Recovery actions have been started at once and after a short periodthere will be another alarm, which tells the reason for the recovery:1001 UNIT RESTARTED or1010 NO RESPONSE TO UNIT SUPERVISION MESSAGE

Supplementary information fields

InstructionsThe alarm requires no actions.

The alarm does not have the supporting rule because the recovery actionshave been started and activated by the supervisor.

CancellingNo cancelling.

Page 170: Descrption alarms - GSM NOKIA - 1000 à 1999

170 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1301 PCU DIGITAL SIGNAL PROCESSOR RESTART

104 1301 PCU DIGITAL SIGNAL PROCESSOR RESTARTMeaning

The PCU digital signal processor (DSP) has not answered to a supervisionmessage sent from the PCU Power Quicc processor, or the DSP has reportedthat a critical process running on it has died.

Due to the failure, the signal processor and the data channelshandled by it are temporarily out of use.The PCU Power Quicc processor tries to reload and restart the DSP.

Supplementary information fields1 slot position number of the plug-in unit in the cartridge. 0xFF means that the slot position number is not available

2 plug-in unit index of the plug-in unit in the cartridge

3 number of the restarted DSP (0...7)

4 01 Periodic Supervision of DSP failed. The PQ2 does not get an answer to a periodic request sent to the DSP for a preconfigured maximum number of times_

02 Failure reported by DSP itself. The Component Manager of the DSP has reported that a critical process running on the DSP has died_

InstructionsThe alarm requires no actions.

CancellingDo not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 171: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 171

Disturbance Printouts (1000-1999) 1302 PAGING OVERLOAD

Id:0900d805806a941aConfidential

105 1302 PAGING OVERLOADMeaning

The BSC sends an overload message to the MSC in overload situationsinside the BSC. At the arrival of this message, the MSC will decreasethe amount of paging by a certain percentage. This will help the BSCto cope with the unusually high amount of paging messages.

The BSC sets the alarm when a predefined threshold of discardedpaging messages has been exceeded.

Supplementary information fields1 the count of Overload message that BSC has been sent to MSC in overload situations

2 the count of rejected ps-paging messages (gb-interface) inside the BCSU

3 the count of rejected cs-paging messages (gb-interface) inside the BCSU

4 the count of rejected paging messages (A-interface) inside the BCSU

InstructionsThe alarm requires no actions.

The alarm informs which BCSU unit has overload.

CancellingDo not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 172: Descrption alarms - GSM NOKIA - 1000 à 1999

172 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1339 ACTIVE FRAMER UNIT FAILURE

106 1339 ACTIVE FRAMER UNIT FAILUREMeaning

The system has detected a failure in the active framer STM-1/OC-3interface unit. The failure was detected in the counterpart unit eitherby the switchover logic circuit or because of consecutive failures inthe active framer unit supervision. The counterpart unit has taken therole of the active framer unit and recovery actions have been started forthe failed unit.

Supplementary information fields1 00 unknown reason

01 failure is detected by means of heartbeating

02 failure is detected by switchover logic circuit

InstructionsThe alarm supports the activation of the automatic recovery for theobject unit. You can check the supporting amount of the alarm withthe MML command ARO.

The automatic recovery starts a fault diagnosis program which givesa diagnosis report indicating the possible hardware fault. If necessary,replace the defective plug-in unit.

If the automatic recovery and fault diagnosis was not started after thealarm occurred, or if the automatic fault diagnosis did not find anyhardware faults, do the following:1. Use the MML command UDU to run a fault diagnosis for the object unit of the alarm in order to find possible hardware faults. If necessary, replace the defective plug-in unit.2. Use the service terminal command clog to check in the error log of the Chorus plug-in unit that no major software defects have occurred in the functional unit.3. If you find defects in the functioning of the software, fill in a Failure Report and send it to your local Nokia Siemens Networks representative. Attach the contents of the Chorus computer log to the Failure Report.4. If you could not find any defects in the plug-in unit and restarting the functional unit did not solve the problem, contact your local Nokia Siemens Networks representative.

CancellingDo not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 173: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 173

Disturbance Printouts (1000-1999) 1339 ACTIVE FRAMER UNIT FAILURE

Id:0900d805806a941aConfidential

The system supervises the object unit of the alarm and cancels thealarm automatically also if the defective hardware block passes twoconsecutive tests.

Page 174: Descrption alarms - GSM NOKIA - 1000 à 1999

174 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1340 HOTLINK FAILURE

107 1340 HOTLINK FAILUREMeaning

Plug-in unit HOTLink cable or transmission fault detected.

Supplementary information fields1 type of the plug-in unit causing the alarm

FFFF means that the plug-in unit type cannot be given

2 index of the plug-in unit causing the alarm

FFFF means that the plug-in unit index cannot be given

3 index of the HOTLink interface

4 the exact error code of the HOTLink test. Possible reasons are:

0040 HOTLink sfp module unplugged 0080 HOTLink fault 0100 HOTLink CRC transmission fault

InstructionsChange the faulty HOTLink cable indicated in the additional informationof the alarm.

The traffic is automatically changed from faulty HOTLink cable toexisting redundant HOTLink by the system.

CancellingNo cancelling

Page 175: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 175

Disturbance Printouts (1000-1999) 1347 CS PAGING COORDINATION ACTIVA-TION/DEACTIVATION FAILED

Id:0900d805806a941aConfidential

108 1347 CS PAGING COORDINATION ACTIVA-TION/DEACTIVATION FAILEDMeaning

Activation or deactivation of the feature paging coordination in BSC has failed.

Supplementary information fields1 error type: The reason why activation/deactivation has failed

13028 NO SYSTEM INFORMATION ACKNOWLEDGEMENT MESSAGES RECEIVED FROM LAYER 2

14269 ILLEGAL BTS CONFIGURATION

14270 NOT ALL MANDATORY SYSTEM INFORMATION MESSAGES ARE RECEIVED BY TRX

14277 ILLEGAL INITIALIZATION VALUE FOR CCCH_CONF IN SYTEM INFORMATION MESSAGE TYPE 3

14282 ILLEGAL INITIALIZATION VALUE FOR DRX_TIMER_MAX FIELD IN SYSTEM INFORMATION TYPE 13

14283 ILLEGAL INITIALIZATION VALUE FOR ACC_BURST_TYPE IN SYSTEM INFORMATION TYPE 13

14284 THE VALUE OF BS_AG_BLKS_RES CANNOT BE CHANGED

14285 THE VALUE OF BS_PA_MFRMS CANNOT BE CHANGED

14286 THE VALUE OF CCCH_CONF CANNOT BE CHANGED AT RUNTIME

14287 SI13_PBCCH_LOCATION CANNOT BE CHANGED IN SYSTEM INFORMATION TYPE 3 AND 4

14288 BCCH-EXT CANNOT BE CREATED

14289 BCCH-EXT CANNOT BE RELEASED

14290 THE VALUE OF DRX_TIMER_MAX CANNOT BE CHANGED

14291 THE VALUE ACC_BURST_TYPE CANNOT BE CHANGED

14396 NO SI_END_ACK/NACK MESSAGE FROM TRX

16116 OPTIONAL FEATURE OF CONNECTSITE IS NOT ALLOWED BY BTS

InstructionsThe alarm informs which BCSU unit paging coordination feature activation/deactivation has failed. Activation/deactivation of the paging

Page 176: Descrption alarms - GSM NOKIA - 1000 à 1999

176 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1347 CS PAGING COORDINATION ACTIVA-TION/DEACTIVATION FAILED

coordination feature should be tried again by modifying NMO parameter or the state of the licence.

CancellingDo not cancel the alarm. The alarm is cancelled automatically by the system.

Page 177: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 177

Disturbance Printouts (1000-1999) 1400 AFS RESTARTED

Id:0900d805806a941aConfidential

109 1400 AFS RESTARTEDMeaning

An internal restart has occurred in the AFS plug-in unit.

Supplementary information fields1 type of AFS plug-in unit

2 index of AFS plug-in unit

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 178: Descrption alarms - GSM NOKIA - 1000 à 1999

178 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1423 NO RESPONSE FROM MAIN CLOCK

110 1423 NO RESPONSE FROM MAIN CLOCKMeaning

No response is obtained from the active unit maintaining the main clock.

Supplementary information fields

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 179: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 179

Disturbance Printouts (1000-1999) 1425 OVERFLOW IN ALARM BUFFERING

Id:0900d805806a941aConfidential

111 1425 OVERFLOW IN ALARM BUFFERINGMeaning

The alarm system has received more alarm output tasks than it is ableto buffer for outputting or for sending to the Q3 core system. However,the alarms that are not output or sent to the Q3 core system aresaved normally in the alarm system log file (ALHIST), from which they canbe output with an MML command. The alarm is set after all buffered alarmoutput tasks have been processed and sent forward from the alarm systemafter a buffer overflow.

Supplementary information fields1 0 buffer used for buffering the alarms to be output has overflown

1 buffer used for buffering the alarms to be formatted for sending to the Q3 core system has overflown

2 number of alarms not output or sent to the Q3 core system

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 180: Descrption alarms - GSM NOKIA - 1000 à 1999

180 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1431 MMI SYSTEM OVERLOAD

112 1431 MMI SYSTEM OVERLOADMeaning

The MMI system is overloaded.

Supplementary information fields

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 181: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 181

Disturbance Printouts (1000-1999) 1432 DISTURBANCE IN COMMAND CALENDAR

Id:0900d805806a941aConfidential

113 1432 DISTURBANCE IN COMMAND CALENDARMeaning

A temporary disturbance has been detected in the commandcalendar operation.

The command calendar interrupts the execution of the calendartask that was being executed and blocks the task. An exceptionis made with those command files that are supposed to be executedmore than once and of which execution is not interrupted althoughsome of the commands in the file fail (marked as NOINT in theCFTYPE column of the execution printout of the MML command ICL):these calendar tasks are not blocked.The blocked tasks are not executed before the fault has beencorrected and the blocking is removed.

If the fault is permanent, then also the alarm 2430, ERROR INCOMMAND CALENDAR, is set.

Supplementary information fields1 error specification

MML error: 01 creation of MML session has failed 02 interruption in session

error in execution: 03 syntax error 04 semantics error 05 command has failed 06 password check error 07 loading error 08 data transmission error 09 insufficient authority 0A OMU in working state TE or SE 0B contradictory MML program running

COFFER error: 0C command not blocked 0D command not deleted 0E either command or control parameters not available 0F command not transferred to execution queue

IOMANA error: 10 opening of logical file has failed 11 connection of logical file has failed

message exchange error:

Page 182: Descrption alarms - GSM NOKIA - 1000 à 1999

182 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1432 DISTURBANCE IN COMMAND CALENDAR

12 time-out

2 identifier of the task in the command calendar. This identifier can be seen in the ID column of the execution printout of the MML command ICL and points out the command calendar task which was been executed when the disturbance occurred

3 name of the command file been executed without the extension .CMD

4 index of the command in command file

InstructionsYou can check which calendar task execution has failed from theMML session log/MML command log (with the MML command IGO), fromthe command calendar queues (with the MML command ICL) or fromthe execution printouts.

For more information, see instructions on MML commands andcommand calendar.

NOTE! If the command calendar has blocked the calendar task, the blocking must be removed in all cases mentioned below after the fault has been corrected: otherwise the task cannot be executed again.

You can check whether the calendar task is blocked with the MML command ICL: the blocked commands are marked with the identifier BLC in the QUE column of the output. For example, ICL; outputs data of all tasks. You can remove the blocking with the MML command ICB. For example, ICB:11:UNBLOCK; removes the blocking from the calendar task 11.

If the value of the supplementary information field 1 is 01,the calendar task cannot be executed, because:

a) all MML sessions are busy. Do the following:

1. Ask a user to close his/her MML session, so that a command calendar can start an MML session.

2. Check if the alarm 2427, MMI SYSTEM FILE ERROR, is set. If the alarm is set, act according to its instructions.

3. If the calendar task is blocked, remove the blocking with the MML command ICB.

b) the calendar task has been created by using a username that

Page 183: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 183

Disturbance Printouts (1000-1999) 1432 DISTURBANCE IN COMMAND CALENDAR

Id:0900d805806a941aConfidential

has been deleted. Do the following:

1. Remove the task from the calendar with the MML command ICD.

2. Add the same task to the calendar again with the MML command ICI. Note that ICD does not delete the command file from the disk, only from the calendar: you can add the same command file to the calendar again, if it is not deleted from the disk.

3. If the calendar task is blocked, remove the blocking with the MML command ICB.

If the value of the supplementary information is 02, the MMLcommand has made a memory protection error. Check if the alarm1078, PROCESS EXCEPTION, is set. If the alarm is set, actaccording to its instructions.

If the value of the supplementary information is 03, the commandin the calendar (including the commands of the command files inthe calendar) cannot be executed, because its syntactic structureis faulty. Correct the command with the MML command ICM so thatit conforms to the syntactic rules of the command.

If the value of the supplementary information is 04, the commandin the calendar (including the commands of the command files inthe calendar) cannot be executed, because its semantic structureis faulty. Correct the command with the MML command ICM so thatit conforms to the semantic rules of the command.

If the value of the supplementary information is 05, do thefollowing:

a) If the execution printouts of the calendar tasks are directed to the printer (you can check with the command IID::COMCAL; where the printout are directed to):

1. Check with the MML command ISI, whether the printer is working. The following command outputs information about the printer LPT-0:

ZISI::LPT,0;

2. If the printer does not work, correct the fault (eg. add paper).

3. Remove the blocking from the command with the MML command ICB.

RECOMMENDATION: Direct the printouts also to the BBU-0, if you want that the command calendar is working even when the printer

Page 184: Descrption alarms - GSM NOKIA - 1000 à 1999

184 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1432 DISTURBANCE IN COMMAND CALENDAR

is not working. Direct the printouts through the semipermanent logical file (see the instructions given on the supplementary information value 10 at the end of the description).

b) If the execution outputs are directed to the disk file (you can check with the command IID::COMCAL; where the printouts are directed to):

1. Check with the MML command ISI that the disk is not damaged. The following command outputs information about the disk:

ZISI::WDU;

2. If the disk is damaged, change the disk.

3. If the disk is not damaged, check with the MML command IWX, if there is space in the file for the printouts. The following command outputs data from the file CCALENDAR, whose name ends with LOG.

ZIWX::WS::MMDIRE:CCALENDAR,LOG;

If there is no space in the file, direct the printouts to another file. It is recommended that the printouts are directed to a ring file.

4. If the calendar task is blocked, remove the blocking with the MML command ICB.

RECOMMENDATION: Direct the printouts also to the BBU-0, if you want that the command calendar is working even when the printer is not. Direct the printouts through the semipermanent logical file (see the instructions given on the supplementary information value 10 at the end of the description).

c) If the calendar task is a command file:

1. Check with the MML command IDL that the command file is not faulty. If the file is faulty, an error message is output.

2. If the file is faulty , edit it with the MML command IEE. Check eg. that the file structure is correct (the commands are one below the another in the right order and comments are within the comment characters).

3. If the calendar task is blocked, remove the blocking with the MML command ICB.

Page 185: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 185

Disturbance Printouts (1000-1999) 1432 DISTURBANCE IN COMMAND CALENDAR

Id:0900d805806a941aConfidential

d) If the alarm 2427, MMI SYSTEM FILE ERROR, is also set, act according to its instructions.

If the value of the supplementary information is 06, there hasbeen a password check error. Fill in a Problem report and sendit to your local Nokia Siemens Networks representative.

If the value of the supplementary information is 07, loading theMML program that executes the command to memory has failed.Do the following:

1. Check whether the alarm 2427 is set. If 2427 is set, act according to its instructions.

2. If the calendar task has been blocked, remove the blocking with the MML command ICB.

If the value of the supplementary information is 08, there hasbeen a data transmission error. Fill in a Problem report andsend it to your local Nokia Siemens Networks representative.

If the value of the supplementary information field is 09,the calendar task cannot be executed, because:

a) the command calendar has no authority to execute the command or because the user who has added the command into the command calendar has no authority to execute the command.

1. If you want to execute the task from the command calendar, you can change, with the MML command IAA, either the command calendar authorities or the authorities of that user who has added the task into the command calendar. You can use the command IAA only if you have the authority to use it.

2. If the task is blocked, remove the blocking with the MML command ICB.

b) you cannot execute the command from the command calendar. These commands include the interactive commands, that is, those commands that output questions which the user needs to answer before the command can be executed. For example, ICI is an interactive command. Those commands that require the user only to confirm the execution of the command (Y/N) can be executed from the command calendar.

Execute the command normally without using the command calendar.

If the value of the supplementary information is 0A, the calendartask cannot be executed because the OMU is at state TE or SE andan attempt has been made to execute an MML command that must notbe executed at TE and SE states. Do the following:

Page 186: Descrption alarms - GSM NOKIA - 1000 à 1999

186 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1432 DISTURBANCE IN COMMAND CALENDAR

1. Change the state of the OMU into WO with the MML command USC.

2. If the calendar task has been blocked, remove the blocking with the MML command ICB.

If the value of the supplementary information is 0B, the calendartask cannot be executed because at the same time that the commandcalendar is executing a specific command, another user is usingsome command that must not be used at the same time with thecommand in question. If, for example, another user is executingthecommandUSU,thecommandcalendarcannotatthe same timeexecute the commands of the command group WR.If the command task has been blocked, remove the blocking withthe MML command ICB.

If the value of the supplementary information is 0C, 0D, 0E, 0F,act according to the instructions of the alarm 2430, ERROR INCOMMAND CALENDAR.

If the value of the supplementary information is 10, the logicalfile COMCAL needed in the execution of the calendar tasks has notbeen created.

1. Check with the MML command IID, whether the logical file COMCAL has been created:

ZIID::COMCAL;

2. If the logical file COMCAL has not been created, create it and connect the printer that you want to it. It is recommended that the printer LPT-0 and BBU-0 are connected to the COMCAL: in this case, the execution printouts of the calendar tasks are output to the printer and the BBU-0 ensures the functioning of the command calendar even when the printer is not functioning. Do the following:

a) Create a logical file COMCAL and connect a printer LPT-0 with the MML command IIF:

ZIIF::COMCAL,S:DEV=LPT-0

b) Connect the BBU-0 to the logical file COMCAL.

Page 187: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 187

Disturbance Printouts (1000-1999) 1432 DISTURBANCE IN COMMAND CALENDAR

Id:0900d805806a941aConfidential

First, create the semipermanent logical file and connect it to BBU-0 with the MML command IIF. The following command creates the file BYTEBASKET:

ZIIF::BYTEBASKET,S:DEV=BBU-0;

Then add the semipermanent logical file you have created as one of the targets of the COMCAL with the MML command IIS:

ZIIS::COMCAL::LF=BYTEBASKET;

3. Find out why the logical file COMCAL has not been created. Check whether the COMCAL is in the PLFILEG2 file. The PLFILEG2 file is in the LFILES directory. Output the contents of the file in the following way:

a) Define the directory where you output a file from with the MML command IWX:

ZIWY:S:UNIT=OMU:PATH=LFILES;

b) Output the contents of the file with the MML command IBT:

ZIBT:WDU,S,PLFILEG2,IMG;

If the COMCAL is not found in the PLFILEG2 file, the software build contains the wrong version of the PLFILEG2 file. Contact the local Nokia Siemens Networks representative.

If the COMCAL is in the PLFILEG2 file, there has been an error. Find out the error with the help of alarms and logs.

If the value of the supplementary information is 11, the logical file COMCAL needed in the execution of the calendar tasks is reserved for the execution of another calendar task or some user is changing its connections.

Wait until the other calendar task is finished or that the connections of the COMCAL have been changed.

CancellingNo cancelling.

Page 188: Descrption alarms - GSM NOKIA - 1000 à 1999

188 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1548 MTP CONFUSION MESSAGE RECEIVED

114 1548 MTP CONFUSION MESSAGE RECEIVEDMeaning

An MTP confusion message has been received in the exchange.The signalling point indicated by the originating pointcode given in the 3rd supplementary information field has notidentified the signalling network management message. Theheading code of the signalling network management messageis given in the 6th supplementary information field.

Supplementary information fields1 SIO in MTP confusion message

2 destination point code in MTP CONFUSION message

3 originating point code in MTP CONFUSION message

4 heading code of MTP CONFUSION message

5 implementation level indicator in MTP CONFUSION message

6 confusion_msg_id in MTP CONFUSION message, i.e. a heading code that was not identified

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 189: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 189

Disturbance Printouts (1000-1999) 1557 EVENT HANDLER CANNOT WORK PROPER-LY DUE TO FILE SERVICE FAILURE

Id:0900d805806a941aConfidential

115 1557 EVENT HANDLER CANNOT WORK PROPERLY DUE TO FILE SERVICE FAILUREMeaning

Event handler cannot save its own attributes in the disk file orthe file services for saving and reading the events have failed.If the file services are not functioning, they prevent or disturbthe functioning of the event handler.

Supplementary information fields1 error code You can check its meaning in General Error Messages of System

2 disk file identifier Disk file where attributes cannot be saved. Value zero indicates that the file services for saving and reading the events have failed

3 family identifier Family which fails to provide the requested file service

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 190: Descrption alarms - GSM NOKIA - 1000 à 1999

190 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1569 CRITICAL LIMIT IN SECURITY REPORTING REACHED

116 1569 CRITICAL LIMIT IN SECURITY REPORT-ING REACHEDMeaning

The critical limit of a security reporting counter has been reached.

Supplementary information fields1 the security reporting counter that has reached its critical limit:

02 - counter for unauthorised users of service terminal 04 - counter for unauthorised users of the network 05 - counter for use of network: unauthorised commands 07 - counter for unauthorised MML users 08 - counter for unauthorised MML commands 10 - counter for unsuccessful saves in MML log file 11 - counter for unsuccessful MML command checks 12 - counter for unsuccessful subscriber identifications 13 - counter for unidentified IMSI numbers 14 - counter for IMEI IDs on black list 15 - counter for unidentified IMEI IDs

InstructionsUse the MML command IRO:<report type> to output a detailed securityreport. Check, against the report, if anything out of the ordinaryhas occurred, and modify, if necessary, the limit value of the counterin question so that it reflects more accurately what is considered anormal situation. However, if the counter's value was normal, find outwhy the critical limit was exceeded.

CancellingNo cancelling.

Page 191: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 191

Disturbance Printouts (1000-1999) 1570 SECURITY LOG ALARM LIMIT REACHED

Id:0900d805806a941aConfidential

117 1570 SECURITY LOG ALARM LIMIT REACHEDMeaning

The number of events written in the Security Reporting Transaction DataFile (LETTER) during a monitoring period has reached the preset alarmlimit.

Supplementary information fields1 alarm limit of LETTER as a percentage

2 length of monitoring period in days

3 starting date of monitoring period

4 number of records in LETTER

InstructionsA certain number (indicated by the alarm limit and given as apercentage of all records) of events have been entered in the fileduring a monitoring period. A back-up copy of the file should be made,otherwise data will be lost as new records are written over old ones.

CancellingNo cancelling.

Page 192: Descrption alarms - GSM NOKIA - 1000 à 1999

192 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1578 CONFUSION IN BSSMAP SIGNALING

118 1578 CONFUSION IN BSSMAP SIGNALINGMeaning

This alarm is issued if a faulty message or a CONFUSION message isreceived from the partner exchange.

Supplementary information fields1 layer 3 BSSMAP message type The message type values can be found in 3GPP 48.008, chapter 3.2.2.1 Message Type

2 typical causes of refusing the message: 51H = invalid message contents 52H = information element or field missing 53H = incorrect value 54H = unknown message type 55H = unknown information element 60H = protocol error between the BSC and the MSC

If the direction is 0, that is, if the partner exchange has sent the CONFUSION message, the cause for the refusal can be any of the Cause values defined in 3GPP 48.008 (chapter 3.2.2.5)

3 direction of the message that caused the alarm 0 = self-sent message (the partner exchange has sent the CONFUSION message) 1 = message sent by the partner exchange

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 193: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 193

Disturbance Printouts (1000-1999) 1580 GLOBAL RESET FAILURE

Id:0900d805806a941aConfidential

119 1580 GLOBAL RESET FAILUREMeaning

The BSC cannot send an acknowledgment to the Global resetmessage. The BSC does not transmit traffic.

Supplementary information fields1 signalling point code of the MSC

2 program family found to be faulty. FFFF : program family unknown

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recovery forthe object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 194: Descrption alarms - GSM NOKIA - 1000 à 1999

194 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1582 CONNECTION OR RELEASE ERROR

120 1582 CONNECTION OR RELEASE ERRORMeaning

The establishment or release of the connection has failed.The call fails or a connection may be left in the marker.

Supplementary information fields1 number of the A interface PCM circuit

This is a PCMCON record index

2 time slot of the A interface PCM circuit

3 number of the external PCM circuit In combined BSC3i/TCSM3i ET_PCM means Ater PCM between GSW2KB and TR3E/A

4 number of the transcoder PCM circuit

5 time slot of the transcoder PCM circuit

6 number of Abis interface PCM circuit

This is a PCMCON record index

7 time slot of Abis interface PCM circuit

8 number of external PCM circuit

9 time slot of the external PCM circuit

10 sub-time slot of the external PCM circuit

11 error code 61 : unkown message identification 62 : unused PCM 63 : unused circuit 6A : test word test error 6B : test word swtst status error 6D : connection status error 6E : connection parity error 6F : connection read error 70 : HWILIB function call fails (virtual circuit conversions) 71 : data from HWILIB is erroneous (virtual circuit conversions)

12 failed connection or release 02 : connection failed

Page 195: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 195

Disturbance Printouts (1000-1999) 1582 CONNECTION OR RELEASE ERROR

Id:0900d805806a941aConfidential

05 : release failed 03 : marker does not answer to the connection or release message

InstructionsCheck in the alarm history if there are several alarms concerninga certain A interface or Abis interface circuits. Solve the possibleconfiguration problems on these circuits. You can interrogate the circuitgroup information with the MML command RCI.

The alarm supports the activation of the automatic recovery forthe object unit. You can check the supporting amount of the alarm withthe MML command ARO.

Check if there are other alarms related to this alarm. Follow theinstructions given for them.

CancellingDo not cancel the alarm. The system cancels the alarmautomatically when the fault has been corrected.

Page 196: Descrption alarms - GSM NOKIA - 1000 à 1999

196 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1583 LAPD MSG DISTRIBUTION PROBLEM

121 1583 LAPD MSG DISTRIBUTION PROBLEMMeaning

The PXRECE (Primary Rate Access Receiving Program Block) hasreceived messages from the D-channel, but it has not been ableto route the messages forward. The reason for this can be thatthe message received from the LAPD link is erroneous. The errorsituation is not a serious one, but if there are several consecutivealarms with the same D-channel system identifier, there may be anerror in the PXRECE distribution table or a disturbance in theLAPD link.

Supplementary information fields1 identification of the D-channel system (hexadecimal number)

2 identification of the D-channel system (name)

InstructionsUse the MML command AHP to check other alarms concerning the sameunit for a period of approximately one hour before this alarmoccurred. If the other alarms do not indicate a link fault andif there are BCF/TRX links created under the link identificationmentioned in this alarm, the fault is in the PXRECE distributiontable. To correct the situation, you can perform a switchover inthe unit that set the alarm by using the MML command USC.The switchover updates the PXRECE distribution table.

CancellingNo cancelling.

Page 197: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 197

Disturbance Printouts (1000-1999) 1585 ABNORMAL A INTERFACE CIRCUIT RELEASE

Id:0900d805806a941aConfidential

122 1585 ABNORMAL A INTERFACE CIRCUIT RELEASEMeaning

The GSM speech circuit of the A interface is released in an abnormalmanner, which causes the call to be cleared from the speechcircuit in question.

Supplementary information fields1 number of the PCM circuit

this is: - number of the external PCM circuit, if GSW and unsubmultiplexed A interface are used

- number of the SMUX PCM, if GSW and submultiplexed A interface are used

- PCMCON record index, if GSWB is used

2 time slot of the PCM circuit in question

3 circuit Identification Code (CIC)

4 PCM circuit part of Circuit Identification Code. This is 65535d , if the environment is T1 (ANSI 1.544 Mbit/s)

5 time slot part of Circuit Identification Code. This is 255d, if the environment is T1 (ANSI 1.544 Mbit/s)

6 number of the external PCM circuit. This is 65535d, if GSW is used in TCSM3i for combined BSC3i/TCSM3i installation ET_PCM means Ater PCM between GSW2KB and TR3E/A

7 time slot of the external PCM circuit. This is 255d, if GSW is used

8 sub-time slot of the external PCM circuit. This is 255d, if GSW is used

9 number of the transcoder PCM circuit. This is 0xFF, if GSW is used

10 time slot of the transcoder PCM circuit. This is 255d, if GSW is used

11 cause of abnormal release:

Page 198: Descrption alarms - GSM NOKIA - 1000 à 1999

198 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1585 ABNORMAL A INTERFACE CIRCUIT RELEASE

1 = abnormal release of SCCP connection 2 = "Reset circuit" message to a circuit in speech state

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 199: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 199

Disturbance Printouts (1000-1999) 1590 ALARM SYSTEM MESSAGE SENDING BUF-FER FULL

Id:0900d805806a941aConfidential

123 1590 ALARM SYSTEM MESSAGE SENDING BUFFER FULLMeaning

A buffer that is used to supervise the alarm system's messagetraffic requiring acknowledgements is full. Such buffers areused for the collection of history data of both the alarm system'sdistributed and centralised part, as well as for communicationbetween the distributed and centralised parts.

The saturation of the buffer that collects history data maycause the loss of some such data.

The saturation of the buffer that is used for communicationbetween the two parts (distributed and centralised) may causean imbalance between the centralised part of the alarm systemand the distributed part that is sending. This may lead to theloss of some of the set values and cancellations of the alarms.

Supplementary information fields1 type of buffer 01 communication buffer 02 history buffer

2 family identifier of the sender

3 process identifier of the sender

4 type of the receiver's computer unit See Recovery and Unit Working State Administration.

5 index of the receiver's computer unit

6 family identifier of the receiver

7 process identifier of the receiver

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 200: Descrption alarms - GSM NOKIA - 1000 à 1999

200 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1597 I/O DEVICE FOUND FAULTY BY ALARM SYS-TEM

124 1597 I/O DEVICE FOUND FAULTY BY ALARM SYSTEMMeaning

The alarm system has found, having received severaldifferent observations to that effect, that the I/Odevice is defective.

The I/O system has been informed of the fault in the device.

Supplementary information fields1 type of subobject (of the I/O device) suspected faulty FFFF, subobject not specified

2 index of subobject (of the I/O device) suspected faulty FFFF, subobject not specified

3-8 the alarm manual numbers (in BCD format) of the observations that first supported the fault hypothesis

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 201: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 201

Disturbance Printouts (1000-1999) 1598 UNIT FOUND FAULTY BY ALARM SYSTEM

Id:0900d805806a941aConfidential

125 1598 UNIT FOUND FAULTY BY ALARM SYSTEMMeaning

The alarm system has found, having received several differentobservations to that effect, that a functional unit(not the I/O device) is defective.

The recovery system has been informed of the faulty unit.

Supplementary information fields1 type of subobject (of a functional unit) suspected faulty FFFF, subobject not specified

2 index of subobject (of a functional unit) suspected faulty FFFF, subobject not specified

3-8 the alarm manual numbers (in BCD format) of the observations that first supported the fault hypothesis

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 202: Descrption alarms - GSM NOKIA - 1000 à 1999

202 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1623 ERROR DURING SUPERVISION

126 1623 ERROR DURING SUPERVISIONMeaning

Unit type supervision has been interrupted because the SubscriberModule Testing Program Block (SBTSTP) or the Time Slot Based Unit TestProgram Block (TSUPRO) is constantly reserved, or the Message Transferand Switching Service Program Block (MTSWIS) cannot seize the unitto be tested, or the Test Line Management Program Block (LTMANA) isunable to reserve the SUB-E minimeter. The supervision of the unit isinterrupted because the requested task is incorrect, or because no testresult is obtained for the requested test.

Supplementary information fields1 program block:

0060 LTMANA_P 0064 TSUPRO_P 0065 SBTSTP_P 0067 MTSWIS_P

2 error specification:

01 unit type supervision is interrupted 02 supervision of single unit is interrupted

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 203: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 203

Disturbance Printouts (1000-1999) 1630 RAM FAILURE IN SYNCHRONIZATION UNIT

Id:0900d805806a941aConfidential

127 1630 RAM FAILURE IN SYNCHRONIZATION UNITMeaning

A failure has been detected in the RAM memory of the synchronizationunit.

Supplementary information fields

InstructionsSet the unit into test state. Run the diagnostics and replacethe plug-in unit if necessary.

CancellingNo cancelling.

Page 204: Descrption alarms - GSM NOKIA - 1000 à 1999

204 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1660 UPDATE NUMBER MISMATCH

128 1660 UPDATE NUMBER MISMATCHMeaning

The LOGSAV, a hand of the database management system, has sentthe DBSMAN an update, the number of which (update_seq_number) isinconsistent with the DBSMAN's view of what that number should be.One or the other of the processes has failed and may have lost logbuffers. The DBSMAN will now no longer receive log buffers from thedatabase in question, and the database will be dumped, i.e. it iscopied from RAM to the disk, thus correcting the failure automatically.

Supplementary information fields1 database index (some database applications still need this information, although nowadays the database is usually identified based on the values of the following two supplementary information fields, i.e. database name and database occurrence)

2 database name

3 number of database occurence

4 database location

5 family ID of the program block handling the database

InstructionsThe system corrects the fault automatically. If the disturbance keepsrecurring, save the log files of the database unit and the diskupdating system unit and the alarms, and contact your local NokiaSiemens Networks representative.

CancellingNo cancelling.

Page 205: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 205

Disturbance Printouts (1000-1999) 1661 DATABASE MANAGER IN FATAL ERRORSTATE

Id:0900d805806a941aConfidential

129 1661 DATABASE MANAGER IN FATAL ERROR STATEMeaning

An error occurred in the database management system, and thesystem has been set to the "fatal error" state. In the "fatalerror" state, the management system program block acknowledgessupervision messages negatively. As the program block is a criticalone, the system resets the database unit.

Supplementary information fields1 database index (some database applications still need this information, although nowadays the database is usually identified based on the values of the following two supplementary information fields, i.e. database name and database occurrence)

2 database name

3 number of database occurrence

4 error code indicating the reason why the fatal error state was entered. You can check its meaning in General Error Messages of System

InstructionsSave the log of the database unit, or, alternatively, save the blackbox of the unit after the reset for further investigation.

CancellingNo cancelling.

Page 206: Descrption alarms - GSM NOKIA - 1000 à 1999

206 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1662 DATABASE LOADING ERROR

130 1662 DATABASE LOADING ERRORMeaning

Loading of the database fails. If several load attempts fail,the management system is set to "fatal error" state. Becauseof this, the system resets the database unit.

Supplementary information fields1 database index (some database applications still need this information, although the database is usually identified based on the database name and database occurrence)

2 database name

3 number of database occurrence

4 reason for load failure

01 the disk updating system (DBSMAN program block) does not answer when the DBMANA on the WO side asks for permission to load 02 the DBMANA on the WO side does not answer when the DBMANA on the SP side asks for permission to load 03 time supervision expires on the WO side of the database unit during the first load attempt 04 time supervision expires on the SP side of the database unit during the first load attempt

InstructionsReason = 01: Check with the DBD command the state of the diskupdating system serving the database.

Reason = 02: Check with the DBS command the state of themanagement system in the database unit's WO side.

Reason = 03: Check with the DBD command the state of the diskupdating system serving the database. Check with the DBS commandthe state of the management system on the database unit's WO side.Save the log of the database unit's WO side, or,alternatively, save the unit's black box after a reset. Savethe log of the disk update system.

Reason = 04: Check with the DBS command the state of themanagement system on the database unit's WO and SP side.Save the log of the database unit's SP side, or, alternatively,save the unit's black box after the reset. Save the log of the

Page 207: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 207

Disturbance Printouts (1000-1999) 1662 DATABASE LOADING ERROR

Id:0900d805806a941aConfidential

database unit's WO side.

CancellingNo cancelling.

Page 208: Descrption alarms - GSM NOKIA - 1000 à 1999

208 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1663 HAND RESERVATION ERROR IN DATABASE MANAGER

131 1663 HAND RESERVATION ERROR IN DATABASE MANAGERMeaning

The reservation of a transaction or fastread hand fails inthe database management system.

Supplementary information fields1 database index (some database applications still need this information, although nowadays the database is usually identified based on the values of the following two supplementary information fields, i.e. database name and database occurrence)

2 database name

3 number of database occurrence

4 error code indicating why the hand reservation failed. You can check its meaning in General Error Messages of System

5 number of the transaction or fastread hand to be reserved: 00 if on WO side > 03 if on SP side (the number of the hand to be reserved is known)

InstructionsCheck the states of the database management system's hands by means ofthe service terminal extension Family Utilities (FAMUTI).

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 209: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 209

Disturbance Printouts (1000-1999) 1682 SCDFLE UPDATE FAILURE

Id:0900d805806a941aConfidential

132 1682 SCDFLE UPDATE FAILUREMeaning

The distribution or updating of the Working State and ConfigurationFile (SCDFLE) has failed.

Supplementary information fields1 error code presented as a common error code. You can check its meaning with a command of the service terminal extension MRS or in the General Error Messages of System

2 consecutive number of distribution

3 recovery action

4 type of the unit whose data was changed

5 index of the unit whose data was changed

6 number of SCDFLE record

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 210: Descrption alarms - GSM NOKIA - 1000 à 1999

210 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1683 FAULTY UNIT SP-EX

133 1683 FAULTY UNIT SP-EXMeaning

A faulty unit is spare.

Supplementary information fields

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 211: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 211

Disturbance Printouts (1000-1999) 1684 SPARE UNIT WARMUP FAILURE

Id:0900d805806a941aConfidential

134 1684 SPARE UNIT WARMUP FAILUREMeaning

The warm-up of the spare unit fails. The reason may be a faultin the active or in the passive unit. The alarm is issued fromboth units.

Supplementary information fields1 family identifier of the alarm detector

2 error code returned by the alarm detector. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System

3 message bus address of the unit where the error occurred

4 family identifier of the program block that made the error

5 load group where the warming failed

6 file where the warming failed

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of thealarm with the MML command ARO.

CancellingNo cancelling.

Page 212: Descrption alarms - GSM NOKIA - 1000 à 1999

212 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1685 UNIT RESTART FAILURE

135 1685 UNIT RESTART FAILUREMeaning

The restarting of the computer unit fails.

Supplementary information fields1 family identifier of the error detector

2 error code returned by the error detector. You can check its meaning with a commands of the service terminal extension MRS or in General Error Messages of System

3 message bus address of the unit where the error occurred

4 family identifier of the program block that made the error

5 load group where the loading failed

6 file where the loading failed

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 213: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 213

Disturbance Printouts (1000-1999) 1687 RECOVERY ACTION FAILURE

Id:0900d805806a941aConfidential

136 1687 RECOVERY ACTION FAILUREMeaning

The recovery actions in the unit have been interrupted or a subfunctionof a recovery action has failed. The partner program block in theobject unit has not responded, or it has returned an error status.

Supplementary information fields1 error code of recovery action. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System

2 interrupted recovery action

3 family identifier of the error detector

4 error code returned by the error detector. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System

5 message bus address of the unit where the error occurred

6 family identifier of the program block that made the error

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 214: Descrption alarms - GSM NOKIA - 1000 à 1999

214 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1688 FAILURE IN CALL CLEARING

137 1688 FAILURE IN CALL CLEARINGMeaning

A clear request sent to release the calls of the time-slot-basedunit such as the SUB, CNFC, ET, etc. has not been acknowledged.

Supplementary information fields1 type of time-slot-based unit See Recovery and Unit Working State Administration.

2 unit index

3 partner program block

InstructionsCheck if the above-mentioned units have made seizures for calls.If so, release them.

CancellingNo cancelling.

Page 215: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 215

Disturbance Printouts (1000-1999) 1800 SCSI ADDRESS ILLEGAL

Id:0900d805806a941aConfidential

138 1800 SCSI ADDRESS ILLEGALMeaning

There was an attempt to install an I/O device at an SCSI addressthat was already reserved.

Supplementary information fields1 number of SCSI bus 0...1

2 address of device on bus identified in field 1 0...7

3 logical unit number (= LUN) 0...7

the LUN of the master tape drive is always 0, numbers 1...7 are slave tape drivers

InstructionsCheck the SCSI bus addresses of the I/O devices on the SCSI bus.If the alarm occurs in connection with the configuration of the tapeunits, check the parameters of the ISK command.

CancellingNo cancelling.

Page 216: Descrption alarms - GSM NOKIA - 1000 à 1999

216 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1801 MASS MEMORY FILE BACKUP FAILURE

139 1801 MASS MEMORY FILE BACKUP FAILUREMeaning

A copy task has failed. The I/O system has used backgroung processingto carry out the task but copying some of the files failed.

If alarm 1802, BACKUP COPY LOG FAILURE, is set simultaneously withthis alarm, the system has failed to save all the information on thecopy task to the copy log. The copy task execution has been interrupted.

This alarm has no effect on the operation of the rest of the system.

Supplementary information fields1 name identification of the failed copy task. The name is an ASCII string

2 number identification of the failed copy task. The number is a hexadecimal number generated by the I/O system. The name and the number of the task form an explicit identifier

InstructionsCheck the backup copy log to see which copy task failed. Usethe MML commands IPI and IPP to interrogate the log of the copytask in question. Give the copy task name and identification number(shown in Supplementary information fields 1 and 2) as parameters.

For example, if the name of the task is COPY_1998 and theidentification number is 40020010, the following command outputsthe general copy task information:

IPI:NAME=COPY_1998,HANDLE=40020010;

The IPP command displays detailed information on the copied filesand directories. If copying a file failed, the printout shows ageneral error message after the file or directory in question.

IPP:NAME=COPY_1998,HANDLE=40020010;

CancellingNo cancelling.

Page 217: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 217

Disturbance Printouts (1000-1999) 1802 BACKUP COPY LOG FAILURE

Id:0900d805806a941aConfidential

140 1802 BACKUP COPY LOG FAILUREMeaning

Saving the copy task information in the disk's copy log has failedat least partly.

The fault may have been caused, for example, by a disturbance in theI/O system, a fault in an I/O device, or a load peak of the unit,because of which information could not be recorded within thedefined time period.

If alarm 1801, MASS MEMORY FILE BACKUP FAILURE, is set simultaneouslywith this alarm, the background processing of the backup copy taskhas been interrupted. Otherwise, the copy task itself has succeededbut the system was not able to record all the information connectedto the copy task to the copy log.

This alarm has no effect on the operation of the rest of the system.

If disk alarms are set simultaneously with this alarm, a disturbanceor a fault has been detected in the disk system and it has preventedthe normal use of the copy log. The following alarms are disk alarms:0860 DISK NOTICE, 1860 DISK DISTURBANCE, 2860 DISK FAILURE,2861 NO ACCESS TO DISK, and 2862 DISK CHECKSUM ERROR.

Supplementary information fields1 general error message of the system. You can check its meaning in General Error Messages of System

2 name identifier of the copy task whose recording in the copy log failed. The name is an ASCII string

InstructionsIt may be possible to interrogate information on the copy taskmentioned in Supplementary information field 2 with the MML commandsIPI and IPP. The I/O system has however failed to record some (orpossibly all) information.

You may find more information in the system log, which you caninterrogate with the service terminal command ZGD.

If alarm 1801, MASS MEMORY FILE BACKUP FAILURE, is not setsimultaneously with this alarm for the same copy task, the copytask was successful, even though information on it is not availablein the log.

If alarm 1801 is also set, you should start the copy task again.

Page 218: Descrption alarms - GSM NOKIA - 1000 à 1999

218 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1802 BACKUP COPY LOG FAILURE

CancellingNo cancelling.

Page 219: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 219

Disturbance Printouts (1000-1999) 1804 IP ROUTING RESOURCE SHORTAGE

Id:0900d805806a941aConfidential

141 1804 IP ROUTING RESOURCE SHORTAGEMeaning

The IP Routing feature is experiencing an unexpected resourceshortage.

The IP routing capability of the system is temporarily reduceduntil the routing database has been reconstructed from neighboringrouters.

The telephony capabilities of the switch are not affected.

Supplementary information fields

InstructionsFill in a Problem Report and send it to your local technicalsupport.

CancellingNo cancelling.

Page 220: Descrption alarms - GSM NOKIA - 1000 à 1999

220 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1806 PRINTER SPOOLER DISABLED

142 1806 PRINTER SPOOLER DISABLEDMeaning

Printing system cannot use the spooler. This happens, for example,when the SCSI-bus or hard disks go to TEST-state. The failure doesnot disable the printing system, but new printing tasks are handledin non-spoolered mode. Handling printing tasks in non-spoolered mode ismore unreliable than in spoolered mode.

The tasks that are in spooler when failure occurs, are executedwhen the spooler is in use again. The system changes automatically fromthe non-spoolered mode to the spoolered mode when the spooler isagain in use and all non-spoolered tasks are completed.

Supplementary information fields

InstructionsTo find out the reason for SCSI-bus's or hard disk's wrong operatingstate, check whether there are other alarms active using the AHO MMLcommand. Follow the instructions given in these alarm descriptions.

Set the SCSI-bus and hard disks to WO-state using the ISC MML command, ifpossible.

CancellingNo cancelling.

Page 221: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 221

Disturbance Printouts (1000-1999) 1809 IP CONFIGURATION INQUIRY SERVICEFAILED

Id:0900d805806a941aConfidential

143 1809 IP CONFIGURATION INQUIRY SERVICE FAILEDMeaning

The alarm is set if IP management shared library (YANLIB) cannotprovide IP configuration inquiry services for applications.Under this situation, the applications will get "no service" returncode when calling the library routines. If the application has failedto receive IP configuration data, it might make the Network Elementunable to provide IP calls services.

Supplementary information fields

InstructionsCheck the computer log to find out the possible cause of the alarm.Fill in a Problem Report and send it to your local Nokia SiemensNetworks representative.

Here are the possible problems:

1. IP configuration files are missing or corrupted. IPv4 configuration is stored to the /etc/if.dat file of RAM disk of POSIX subsystem and the same information is stored to the /LFILES/POCIFCZZ.IMG file on the hard disk of OMU unit. IPv6 configuration is stored to the /LFILES/YEMIP6GX.XML file. VLAN configuration is stored to the /LFILES/VLNRRRGX.XML file.

Get configuration files from the W0 disk and attach them to the problem report and if those files do not exist, report that in the problem report.

2. Read/write disk files failed:

Add both operating and user logs to the problem report.

3. Allocate common buffer failed:

Add both operating and user logs to the problem report.

4. Event Forwarder problem:

Add user logs to the problem report.

5. Name Server problem:

Add user logs to the problem report.

Page 222: Descrption alarms - GSM NOKIA - 1000 à 1999

222 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1809 IP CONFIGURATION INQUIRY SERVICE FAILED

CancellingNo cancelling.

Page 223: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 223

Disturbance Printouts (1000-1999) 1850 BTS TEST REPORT PRINTOUT FAILED

Id:0900d805806a941aConfidential

144 1850 BTS TEST REPORT PRINTOUT FAILEDMeaning

Printing the BTS test report has failed in the reportingsystem of the BSC.

Supplementary information fields1 BCF identifier

2 BTS identifier

3 TRX identifier

4 type of main test

0 = single TRX test with MML 1 = single RAX test with MML 2 = single STM test with MML 3 = single TRX test via Q3 interface 4 = single RAX test via Q3 interface 5 = single STM test via Q3 interface 6 = scheduled TRX test with MML 7 = scheduled STM test with MML 8 = scheduled TRX test via Q3 interface 9 = scheduled STM test via Q3 interface

5 type of STM test

1 = BCCH measurement 2 = originating test call 3 = BCCH carrier wave setting 4 = call information request 5 = transceiver sensitivity measurement 6 = STM test cancellation request 7 = TRX test 8 = TRX loop test 9 = antenna test 0A = antenna loop test 0B = TRX test for MetroSite and UltraSite BTSs 0C = Abis loop test 0xff = not stm test

6 reason for failure (DX error code)

Page 224: Descrption alarms - GSM NOKIA - 1000 à 1999

224 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1850 BTS TEST REPORT PRINTOUT FAILED

DX error code: see General Error Messages of System

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 225: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 225

Disturbance Printouts (1000-1999) 1860 DISK DISTURBANCE

Id:0900d805806a941aConfidential

145 1860 DISK DISTURBANCEMeaning

A disturbance has been detected in the Winchester or floppy disksystem. The disturbance may be caused by a DMADI, DMASI, or SCSIFplug-in unit, the connecting cable, disk controller, disk drive,or by a command that is incorrect, insufficient or unnecessary.

Supplementary information fields1 general error message of the system. You can check its meaning in General Error Messages of System

2 address of the damaged sector of the disk drive, if 1FFFFFH, the sector address is not valid

3 first 8 characters of file name

InstructionsCheck the command. Remove write protection from the floppy disk.Check and replace, if needed, the DMADI, DMASI, or SCSIF plug-inunits, connecting cable, disk controller and disk drive or floppydisk.

CancellingNo cancelling.

Page 226: Descrption alarms - GSM NOKIA - 1000 à 1999

226 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1881 TAPI FAILURE

146 1881 TAPI FAILUREMeaning

Before giving a command concerning the magnetic tape drive,or when making a state inquiry, TAPEDR checks the functioningof the TAPI plug-in unit. If an error is detected, this alarmis issued.

Supplementary information fields

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 227: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 227

Disturbance Printouts (1000-1999) 1882 DMADI FAILURE

Id:0900d805806a941aConfidential

147 1882 DMADI FAILUREMeaning

Before read or write operations TAPEDR checks the functioning ofthe address and byte counters of the DMA channel it uses. If afailure is detected in the operation, this alarm is issued.

Supplementary information fields

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 228: Descrption alarms - GSM NOKIA - 1000 à 1999

228 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1884 LABEL PARAMETER FAILURE

148 1884 LABEL PARAMETER FAILUREMeaning

If no label parameters have been defined for TAPEDR in connectionwith the preformatting or opening command, TAPEDR tries to use theold parameters stored in the data area. This always entails acorrectness test based on the check sum. If an error is detected,TAPEDR fetches the constant values and uses them. At the same time,the system issues this alarm.

Supplementary information fields1 number of the magnetic tape unit

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 229: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 229

Disturbance Printouts (1000-1999) 1885 ERROR IN WRITING DATA TO MAGNETICTAPE

Id:0900d805806a941aConfidential

149 1885 ERROR IN WRITING DATA TO MAGNETIC TAPEMeaning

The error message is a consequence of a failure in the magnetic tapeunit, very poor condition of the tape, a serious malfunction inthe controlling plug-in units (TAPI, DMADI, SCSIF), or erroneoustask parameters sent by the application.

Supplementary information fields1 number of the magnetic tape unit

2 general error message of the system. You can check its meaning in General Error Messages of System

3 block number

InstructionsDetermine (from the error code) whether the cause of the disturbanceis poor tape quality, equipment failure or an erroneous task parameter.

The alarm supports the activation of the automatic recovery for theobject unit. You can check the supporting amount of the alarm withthe MML command ARO.

If the magnetic tape unit has been changed into test state for recovery,find out the cause of the failure and remove the cause before returningthe magnetic tape unit into normal working state (WO-BU). The state canbe changed with the MML command ISC.

CancellingNo cancelling.

Page 230: Descrption alarms - GSM NOKIA - 1000 à 1999

230 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1886 ERROR IN TAPE OPERATION

150 1886 ERROR IN TAPE OPERATIONMeaning

This is an error acknowledgement to some other command than thewrite command. The fault is in the equipment or in the storage medium.

Supplementary information fields1 number of the magnetic tape unit

2 general error code. You can check its meaning in General Error Messages of System

InstructionsIf the error code does not clearly indicate that the fault isin the equipment, change the storage medium. If this does notsolve the problem, an inspection of the equipment is required.

CancellingNo cancelling.

Page 231: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 231

Disturbance Printouts (1000-1999) 1887 BLOCK COUNTER FAILURE

Id:0900d805806a941aConfidential

151 1887 BLOCK COUNTER FAILUREMeaning

TAPEDR contains a duplicated block number counter for each of themagnetic tape units. The contents of one counter are continuouslybehind the other. If the test indicates that the relationshipbetween the two contents has changed, the block numbering isstarted from the beginning, and the system issues this alarm.

Supplementary information fields1 number of the magnetic tape unit

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 232: Descrption alarms - GSM NOKIA - 1000 à 1999

232 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1891 AS7 RESTARTED

152 1891 AS7 RESTARTEDMeaning

The processor of the AS7 plug-in unit has restarted.

Supplementary information fields1 number of AS7 (0..n)

2 state data of AS7:

00 out of service 01 working 02 testing

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 233: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 233

Disturbance Printouts (1000-1999) 1893 O&M CHANNEL SEND OVERLOAD

Id:0900d805806a941aConfidential

153 1893 O&M CHANNEL SEND OVERLOADMeaning

The send buffer of the data transmission connection of the operationand maintenance network is full, or the X.25 network layer has notgranted permission to transmit.

Supplementary information fields1 number of OMI channel (0...n)

2 number of AS7 or AC25 plug-in unit (0...n)

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 234: Descrption alarms - GSM NOKIA - 1000 à 1999

234 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1894 NO RESPONSE TO AS7 SUPERVISION MES-SAGE

154 1894 NO RESPONSE TO AS7 SUPERVISION MESSAGEMeaning

The program controlling the AS7 plug-in unit has not responded to thesupervision message within the specified time.

Supplementary information fields1 number of the AS7 (0...n)

2 state data of the AS7:

00 out of service 01 working 02 testing FF supervision software does not know the state of the AS7

InstructionsThe alarm requires no actions.

The alarm supports the activation of the automatic recoveryfor the object unit. You can check the supporting amount of the alarmwith the MML command ARO.

CancellingNo cancelling.

Page 235: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 235

Disturbance Printouts (1000-1999) 1895 DISTURBANCE IN O&M CHANNEL

Id:0900d805806a941aConfidential

155 1895 DISTURBANCE IN O&M CHANNELMeaning

A disturbance has been detected on the data transmission connectionof the operation and maintenance network.

Supplementary information fields1 number of OMI channel (0...n)

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 236: Descrption alarms - GSM NOKIA - 1000 à 1999

236 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1900 DEGRADED SLIP FREQUENCY

156 1900 DEGRADED SLIP FREQUENCYMeaning

The ET has observed that the clock frequency slips on the incoming E1or T1 circuit exceed the alarm limit defined for the ET. The slips aremonitored for a 24-hour period.

Supplementary information fields1 unit type

2 E1 or T1 circuit number if the unit type is ET

TCSM's internal PCM circuit number (0d..7d) if the unit type is TCSM and the transcoder type is TCSM2

E1 or T1 circuit number on the A interface (0d..15d) or on the Ater interface (16d..31d) if the unit type is TCSM and the transcoder type is TCSM3i

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 237: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 237

Disturbance Printouts (1000-1999) 1901 ET RESTARTED

Id:0900d805806a941aConfidential

157 1901 ET RESTARTEDMeaning

An internal restart has taken place on an exchange terminal.

Supplementary information fields1 unit type

2 index of the internal PCM circuit of TCSM, 0..7d

3 number of ET restarts

InstructionsThe alarm requires no actions.

CancellingNo cancelling.

Page 238: Descrption alarms - GSM NOKIA - 1000 à 1999

238 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1910 COMMUNICATION FAILURE WITH TRX

158 1910 COMMUNICATION FAILURE WITH TRXMeaning

Time supervision has elapsed, or the TRX has sent a negativeacknowledgement to the BSC, which has interrupted the ongoing messageexchange scenario.

Supplementary information fields1 ID number of the BTS site

2 ID number of the base transceiver station

3 ID number of the transceiver

4 general error message of the system. You can check its meaning with a command of the service terminal extension MRS or in General Error Messages of System.

InstructionsCorrect the possible transmission error in the Abis interface, orcorrect the error already indicated by an alarm generated in the TRX.

CancellingDo not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.

Page 239: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 239

Disturbance Printouts (1000-1999) 1911 INVALID URGENCY LEVEL IN TRANSMISSIONALARM

Id:0900d805806a941aConfidential

159 1911 INVALID URGENCY LEVEL IN TRANS-MISSION ALARMMeaning

Transmission equipment has set an alarm with a different urgency levelthan the one defined in the BSC alarm system. There is an erroneous alarmurgency level definition either in the transmission equipment or inthe BSC, or there is disturbance in the Q1 service channel.

This alarm may affect the performance of the BSC transmission equipmentfault management.

Supplementary information fields1 Q1 address of the piece of transmission equipment

2 the functional entity number specifies a physical unit of the transmission equipment, for example a plug-in unit or a daughter board. The number can be 0...254

3 the supervision block number specifies the faulty part of the functional entity, for example a certain line interface or component

4 number of the Q1 service channel in the BSC, 0...27

5 name of the piece of transmission equipment. Not included if the name is in the alarm object field of the alarm printout. See Alarm Structure, Alarm Reference Manual

6 number of the piece of transmission equipment. Not included if the index is in the alarm object field of the alarm printout. See Alarm Structure, Alarm Reference Manual

7 original Q1 fault code received from transmission device

InstructionsUse the MML commands Axx for alarm administration.

To clarify the reason for the fault, see the transmission equipmentoperating manual to check how fault code is classified in the equipment.

If the fault code classification in the equipment is the same as inthe BSC alarm system, there is probably some kind of disturbance inthe Q1 service channel. Otherwise contact your local Nokia SiemensNetworks representative.

Page 240: Descrption alarms - GSM NOKIA - 1000 à 1999

240 DN9813048

Disturbance Printouts (1000-1999)

Id:0900d805806a941aConfidential

1911 INVALID URGENCY LEVEL IN TRANSMISSION ALARM

CancellingNo cancelling.

Page 241: Descrption alarms - GSM NOKIA - 1000 à 1999

DN9813048 241

Disturbance Printouts (1000-1999) 1915 TCSM CLOCK DISTURBANCE

Id:0900d805806a941aConfidential

160 1915 TCSM CLOCK DISTURBANCEMeaning

One of the external synchronisation plug-in units of a TCSM3i cabinethas detected a fault and has set an alarm to the supervising transcoderunit.

Supplementary information fields1 index of the external synchronisation plug-in unit 0d...1d

2 alarm number of the alarm set by the external synchronisation plug-in unit

alarm number can be one of the following

0630 1630

3-9 alarm data related to the alarm set by the external synchronisation plug-in unit

InstructionsThis alarm encapsulates the alarm set by the external synchronisationplug-in unit. For instructions, see the alarm description of the alarmdefined in the second field.

CancellingFor instructions on how to cancel the alarm, see the alarm descriptionof the alarm defined in the second field.