14
delivering tomorrow's technology today Nuclear Scintigraphy Supplies And Accessories Catalogue

delivering tomorrow's technology today - Bartec Technologies

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

delivering tomorrow'stechnology today

Nuclear Scintigraphy Supplies And AccessoriesCatalogue

Version 2.0

Bartec is Europe's leading supplier of Veterinary Nuclear Scintigraphy

Equipment. Bartec provide new and refurbished Gamma cameras, processing

computer systems software and all the necessary accessories. Bartec also

offer building and preparation consultancy, installation and full user training.

Bartec is a privately owned UK company with over thirty years of experience

in the Nuclear Medicine and Nuclear Scintigraphy fields. Bartec are also the

main UK distributor for Biodex accessories.

Bartec Technologies Ltd

Unit 8, Stanhope Gate

Stanhope Road

Camberley

Surrey, GU15 3DW, UK

���� +44 (0) 1276 20842

Fax +44 (0) 1276 20891

Email [email protected]

Website: www.bartectechnologies.com

Version 2.0

Index Page

Bartec Gamma Camera Systems 4

Micas X Plus® Processing Systems 5

Syringe Shields 6

Vial Shields 7

Table Top Shields 8

Hazard Warnings 9

Radiation Monitors 10

Radiation Monitors 11

Dose Calibrator 12

Decontamination 13

+44 (0) 1276 20842 3

Bartec are able to source many items not listed in this catalogue,

please contact us for your special requests

Index

Version 2.0

Bartec Gamma Camera System

4 [email protected]

The Bartec Gamma Camera System is based on a new digital

system or a factory refurbished GE gamma camera detector and

electronics. The detector is installed on a yoke and mounted

onto a variety of transport systems including overhead Jib crane

gantries , overhead gantry hoists and custom hydraulic Crane

arms and stacker systems. The interconnecting detector cables

are routed in such a way as to ensure that there are no trailing

cables on the ground.

The detector is completely sealed to ensure that no body fluids

or contamination can enter. All units are designed for silent

operation to ensure minimise distress for the horse.

Jib Crane mounted

Refurbished GE camera Overhead crane mounted

Refurbished GE camera

Overhead crane mounted

New Digital Rectangular Camera

Version 2.0

MICASXPlus® Processing System

+44 (0) 1276 20842 5

The Bartec MicasXPlus® Processor is an

advanced Nuclear Medicine post processing

system that has been developed in the UK for

human imaging and has users all over the

world . The system contains specific

functionality for Nuclear Scintigraphy such as

Horse motion correction as shown.

The MicasXPlus® system provides all of the

procedures and functionality required for

today's Nuclear Scintigraphy.

Bartec has extensive experience in the field of Nuclear Scintigraphy and

is able to provide advice and consultancy for new and existing

projects. Bartec can also provide a complete package of camera,

processor, accessories, installation and testing, full training for the Users,

including health and safety and service on radiation protection matters.

Automatic Motion Correction Software Before and After Motion Correction

Version 2.0

Syr inge Shields

6 sales@bar tectechnologies.com

The barrel of the shield is constructed of 2 mm thick

tungsten that will reduce rad iation exposure from Tc-

99m by 94%. A 4.2 density lead glass window provides

protection and visibility. The interior of the barrel be-

hind the glass has a white coating that improves the

view of the syringe and contents. A bevel around the

lead glass helps protect it from scratching or breaking.

The Safe-T-Lock design grips and secures the syringe

upon insertion and will release the syringe at the press

of a button. Disposing used syringes is easy; invert the

syringe shield over a Sharps container, press the re-

lease button and the syringe freely disengages.

Pro-Tec III® Syringe Shields:

Syringe Shield, 5 ml 007-736

Syringe Shield, 10 ml 007-738

Pro-Tec III Syringe Shield Pro-Tec II Syringe Shield

The Pro-Tec® II is thin, lightweight and easy to use.

The barrel of the shield is constructed of 1.5 mm thick

tungsten that will reduce rad iation exposure from Tc-

99m by 94%. A 4.2 density lead glass window provides

protection and visibility. The interior of the barrel be-

hind the glass has a white coating that improves the

view of the syringe and contents. A clip secures the

lead glass to the tungsten barrel and makes it easy to

replace scratched or broken glass. A stainless steel

thumb screw holds syringes firmly in place.

Pro-Tec® II Syringe Shields:

Syringe Shield, 5 ml 007-900

Syringe Shield, 10 ml 007-909

Syringe Shield 20 ml 007-917

Replacement Glass for Pro-Tec® II Syringe Shields:

Syringe Shield Replacement Glass, 5 ml 127-789

Syringe Shield Replacement Glass, 10 ml 127-999

Syringe Shield, 5 cc

Syringe Shield 20 cc

Shielded Syringe Carriers

Safely stores and transports syringes, on site, with ei-

ther ⅛” or ¼” lead lining.

Syringe Carrier, Large, 3.2mm lead 001-179

Syringe Carrier, Small, 3.2mm lead 001-181

Version 2.0

Vial Shields

+44 (0) 1276 20842 7

• Virtually unbreakable

• Safe hand ling of rad ioactive liquids

The Tungsten Vial Shield is designed to greatly reduce

exposure to vials containing liquid radioisotopes. The

shield is constructed of .19" (.48 cm) thick tungsten,

equivalent to .38" (1 cm) lead at 150 keV.

Vials can be loaded from the top or bottom of the shield .

A loss-proof slide injection port on the top allows easy

access to the vial septum.

The tough tungsten will retain its shape under the

roughest hand ling and is virtually unbreakable.

Specifications

Dimensions: 3.7 x 7 cm

Inside Diameter: 2.5 cm

Lead Equivalency: .1 cm

Vial Shield, Tungsten, .38" lead equiv 053-805

Tungsten Vial Shield Colour Coded Vial Shields

Colour coding is the easiest way to avoid a mix up.

These vial shield colours match the C.I.S. kits and are

compatible with most rad iopharmaceutical vials. The

body of the vial is constructed of .31" thick lead covered

with a coloured acrylic collar.

A 4.2 density lead glass window provides protection

and visibility.

Vials can be loaded from the top or bottom of the shield .

The top features an attached slid ing lid for easy access

to the vial septum.

Specifications

Dimensions: 4.3 x 7.8 cm

I.D.: 2.7 cm

Lead Shielding: .0.8 cm

Weight: 0.9 kg

Color-Coded Vial Shields without glass:

Vial Shield, (Glucoscan), Red 053-601

Vial Shield, (Osteolite,) Purple 053-602

Vial Shield, (Pulmolite), Light orange 053-603

Vial Shield, (Pyrolite), Blue 053-604

Vial Shield, (Hepatolite), Brown 053-605

Vial Shield, (Microlite), Yellow 053-606

Colour-Coded Vial Shields with glass:

Vial Shield, (Glucoscan), Red 053-701

Vial Shield, (Osteolite), Purple 053-702

Vial Shield, (Pulmolite), Light orange 053-703

Vial Shield, (Pyrolite), Blue 053-704

Vial Shield, (Hepatolite), Brown 053-705

Vial Shield, (Microlite), Yellow 053-706

Version 2.0

Table Top Shields

8 sales@bar tectechnologies.com

• Constructed of lead and lead glass

• Integral stainless steel tray with spill proof lip

• Optional bottom and side shields available

Specifications

Table Top Shields

Lead Shielding: 0.64 cm thick

Dimensions: See d rawings featured .

Viewing Panel: 2.0 mm or 4.0 mm lead glass window

Side Shields

Lead Shielding: 0.64 cm thick

Tabletop Shields:

Shield, Table Top, Standard, .5" lead 042-216

With 2.0 mm lead glass

Tabletop Shield Lead Glass Panels:

Lead Glass Panels can be paired to achieve 4.0 mm lead

equivalency.

Lead Glass Plate, 2.0 mm, Standard 017-121

Side Shield, Standard, .25" lead 042-220

Bottom Shield, Standard, .125" lead 042-218

Standard Table Top Shield Mini Table Top Shield

• Constructed of lead and lead glass

• Integral stainless steel tray with spill proof lip

• Optional bottom and side shields available

Specifications

Table Top Shields

Lead Shielding: 0.64 cm thick

Viewing Panel: 2.0 mm or 4.0 mm lead glass window

Shield, Table Top, Mini, .5" lead 042-016

With 2.0 mm lead glass

Lead Glass Plate, 2.0 mm, Mini 017-810

Side Shield, Mini, .25" lead 042-221

Bottom Shield, Mini, .125" lead 042-018

Version 2.0

Hazard Warnings

Hazard Tape

Hazard tape is a highly visible Magenta and Yellow

warning tape that’s perfect for identifying physical

hazard areas. Constructed of 6ml vinyl, the tape is du-

rable to withstand long term placement.

The tape will adhere to any clean smooth surface.

Tape, Hazard 026-020

Warning Rope

• Brightly coloured—magenta and yellow

• Triple– strand strength

Made of high quality polypropylene, this triple strand

rope assues high visibility and strength.

Rope, Warning (price per foot) 121-072

Diameter 0.8 cm

Minimum order is 100’.

Metal Signs

Metal signs finished in heavy-duty baked enamel on

30-gauge steel with holes for convenient attachment to

inner or outer doors.

Caution radioactive materials 024-999

Caution radiation Area 024-900

Shipping Labels

Pressure sensitive with peel off backing.

Comply with fed eral Regulations, Title 49-

Transportation of Hazard ous Materials Regulations,

Dept. of Transportation, 49CFT, Part 173 as to wording,

symbols.

Label, Radioactive 1 white 20/pkg 030-001

Label, Radioactive 2 Yellow 20/pkg 030-002

Label, Radioactive 3 Yellow 20/pkg 030-003

9 +44 (0) 1276 20842

Version 2.0

Radiation Monitors

10

Personal Dosimeter DKG-21

Stand-alone use or use within the automated PC based system for personal dosimetry control.

Dose accumulation history storage in the non volatile memory with refer-ence to real time.

Dose accumulation history transfer to a PC computer through the integrated infrared port.

Power down prevention mode until all accumulated data has been read from the dosimeter.

Gamma radiation EDR and ED threshold levels programming using on-line to a computer, control keys, or manually.

The blocking of certain indication modes using computer commands on line.

Light and audio alarm of exceeded programmed threshold level of gamma radiation EDR and ED.

Automatic digital display switch off if current gamma background is lower than the preset threshold level and Instant switch on when: - any control key pressed; - the gamma background increases above the preset threshold level; - when the alarm clock rings. Periodic self testing (batteries, detector).

Energy compensated Geiger-Muller counter.

Measurement ranges and basic relative errors: Personal gamma radiation equivalent dose rate HP(10)

µSv/h 0.1…1 000 000; ±15%

Personal gamma radiation equivalent dose HP(10)

mSv 0.001…9 999; ±15%

Energy range of detected gamma and X-ray radiation and energy dependence

MeV 0.05…6.0; (0.05…1.25; ±25%)

Recording resolution of dose accumulation history in the non volatile memory

minutes 5…255

Time of data storage in the non volatile memory

years not less than 10

Data exchange rate through infrared port bit/s 38 400 Positive data exchange distance between the dosimeter and infrared port adapter

m not more than 0.3

Lithium battery (CR2450) life hours 2 200 Operating temperature range °C -10…+50 Weight kg 0.08 Dimensions mm 86×54×9

Radiation Monitor Terra

Five independent measuring channels with alternate indication of data on the single liquid crystal display. Built-in gamma, beta sensitive Geiger-Muller counter.

Prompt evaluation of gamma background within 10 seconds. Automatic subtraction of gamma background at measurement of beta contamination. Measurement results averaging, manually and automatically. Automatic setting of measurement intervals and ranges.

Audio indication of each detected gamma-quantum and beta-particle (with switch off option). Two-tone audio alarm of exceeded programmed threshold levels. Digital display backlight.

Two AAA size batteries. Power supply discharge indication.

Shock resistant frame.

Small weight and dimension parameters.

Features Features

Measurement ranges and basic relative errors:

Gamma and X-ray radiation equivalent dose rate (137Cs):

µSv/h 0.1…9 999; ±15%

Gamma and X-ray radiation equivalent dose (137Cs):

mSv 0.001…9 999; ±15%

Beta-particles flux density (90Sr+90Y):

1/(cm²·min) 10…100 000; ±20%

Equivalent dose accumulation time and accuracy of measurement:

1 min … 100 h; ±0.1 s per 24 h

Energy ranges of measurement and energy dependence:

Gamma and X-ray radiation MeV 0.05…3.0; ±25%

Beta radiation MeV 0.5…3.0; Threshold level programming reso-lution for: - dose rate - dose - flux density

µSv/h mSv

10³/cm²·min

0.01 0.01 0.01

Measurement time intervals seconds 1…70 Battery life hours 2 000 Operating temperature range °C -20…+50 Weight kg 0.15 Dimensions mm 120×52×26

sales@bar tectechnologies.com

Version 2.0

11 +44 (0) 1276 20842

Radiation Monitors

Thermo Scientific Mini 900 Survey Monitor

The Mini-monitor serves as a portable or bench top style radiation counter available with a variety of different

probes to accommodate radiation detection needs. Bartec offer this product with the Type 44A Scintillation

Probe for accurate detection of Tc-99m contamination in Veterinary Practices and Hospitals. The unit is packaged

in durable, lightweight aluminium case, powered either from it’s internal battery pack or from mains power. The unit

contains an internal constant current charger for its rechargeable batteries. Radiation Measurement read-out is on

a large easy to view logarithmically scaled meter. An alarm can be set to trigger at any User selected level on the

scale.

Specifications: Weight: 1 kg (2.2 lbs) Size: 180 x 110 x 165 mm (7” x 4.5” x 6.5”) Batteries: 6 type AA cells, alkaline (IEC LR6) or rechargeable (IEC KR 15/51) Battery Life: Approximately 300 hours at 4hours/day Paralysis Time: Scale corrected to give true reading Meter Integration Time: 1 to 4 seconds set to match counting rate Radiation detector: Type 44A Sodium iodide crystal (32 mm dia. by 2.5 mm thick) mounted on the front surface of the probe to facilitate monitoring of large contaminated areas. Suitable for a range of energies from approximately 15 keV to 250 keV. It is also beta sensitive for energies above 500 keV. Diameter 50 mm Length 180 mm. Aluminum window weight

14 mg cm-2. Radiation Detected: Gamma and X-Rays only Overload Protection: No meter “fallback” with intensities at least 100 times full scale reading Main Power: 12-18 VDC from mains converter unit

Version 2.0

Dose Calibrator

sales@bar tectechnologies.com

Atomlab 400 Dose Calibrator

Designed for facilities receiving unit

doses

Features at a glance:

• Large, easy to read backlit LCD

• Automatic range selection; ranges up to 40 curies of

Tc-99m

• Pre-programmed for 88 most commonly used

radionuclides

• Displays in curies or becquerels

• Small footprint for an economic workspace

• Ultra-fast response

• Self Diagnostic Software

• Remote Ionisation Chamber

• RS-232 bi-directional serial communications port

The RS-232 port enables the Atomlab 400 Dose Calibrator to communicate with most commercially available nuclear medicine management systems. The Atomlab™ 400 provides fast, accurate radionuclide activity measurements with performance that easily complies with the most stringent regulatory requirements. The unit is simple to operate. There is a routine list of ten pre-programmed isotopes plus another seven that can be user defined. Any four isotopes will be displayed at a time. The Atomlab™ 400 display can be mounted on a wall or placed on a desktop. In addition, there is a library containing 88 isotopes listed alphabetically, including Y-90 and Sr-89. Activity is displayed on an LCD panel in either Curie or Becquerel units. Background correction is performed at the touch of a button. Range selection is automatic. Activity measurements are performed by a microprocessor-controlled electrometer located within the detector assembly of the ionisation chamber. The chamber is shielded with .25" (6.3 mm) lead. It can be located up to eight feet away from the display unit. Chamber bias is generated within the display unit by an electronic high voltage supply, eliminating the need for

Dose Calibrator, Atomlab 400 , 230V 086-335

Includes Vial/Syringe Dipper and Well Insert

Optional Items

086-423 Moly Shield, Vial 0.3” lead

086-435 Moly Shield, Syringe 0.3” lead

086-509 Lineator

086-242 Vial/Syringe Dipper

086-241 Well Insert

12

SPECIFICATIONS Isotope Selection Keys: Ten pre-programmed – Tc-99m,

Co-57, Cs-137, I-131, In-111, Ga-67, Xe-133, I-123, Tl-201, and Mo-99; seven additional keys for user-set isotopes; two new isotope keys and a full alphabetical list of 88 isotopes Activity Range: 0.1 µCi to 40Ci (.001 mBq to 1500 GBq) of Tc-99m Energy Range: 25 keV to 3 MeV photons Response Time: One to two seconds for doses greater than 200 uCi; three seconds for doses greater than 20 uCi; 50-100 seconds below 20 uCi of Tc-99m with default threshold, threshold adjustable to reduce counting time Detector Linearity: ±1% or 0.2 µCi, whichever is greater Electrometer Linearity: ±1% or 0.2 µCi, whichever is greater Electrometer Accuracy: ±1% or 0.2 µCi, whichever is greater Overall Accuracy: ±3% or 0.3 µCi, whichever is greater; over-all accuracy is affected by such factors as the accuracy of the specific source calibration, geometric variations due to sample volume or configuration, detector linearity, electrometer accuracy and readout accuracy Repeatability: ±0.3% above 1 mCi short term (24 hr); 1% long term (one yr); exclusive of background Digital Calibration Dial: Four-digit LED dial display with increment/decrement keys to change the value; range is from 0.0 to 999.9 Detector: Well-type pressurized ionization chamber, with Argon fill gas; well opening 2.75" (7 cm), well depth 10.25" (26 cm)

Chamber Gas Pressure: 149KPa gauge (21.6 psig) at 20 degrees C or 250KPa absolute (36.3 psia) at 20 degrees C. IATA regulation 3.2.2.4 Exempts Gases of Division 2.2 from Dangerous Goods Regulations when transported at pressure less than 200KPa gauge (29 psig) at 20 degrees C. Device is shipped standard goods. Detector Shielding: .25" (6.3 mm) lead on all sides except top well opening; supplementary shielding available Chamber Bias: 355 ± 5 volts Environmental Operating Conditions: Temperature: 0-40° C Humidity: 0-90% rh, non-condensing Power Requirements: 100 to 240 VAC, 0.6 – 0.3 amps, auto switching; APS Power Supply (APS22ES-150160), for medical use Line Frequency: 50/60 Hz; detachable line cord; built-in EMI filter and transient suppression Detector and Interface Cables: 8' (243 cm) long, six conductor cables (two carry power, two for chassis ground, two carry serial data for digital I/O)

Display Unit: Dimensions: 6.75" w x 6" depth x 5" h (17.1 x 15.3 x 12.7 cm) Weight: 3.6 lb (1.64 kg); desktop or wall mountable Detector Unit: Dimensions: 6" dia x 15.5" h (15.24 x 39.37 cm) Well I.D.: 2.75" dia x 10.5" h (7 x 26.7 cm) Well I.D. with Liner: 2.5" dia x 10.25" h (6.35 x 26 cm) Lead Shielding: .25" thick (6.3 mm) Weight: 35 lb (16 kg)

Version 2.0

Decontamination

+44 (0) 1276 20842 13

Radiacwash has been in use since 1951 it is the most

popular general-purpose decontamination solution

specifically created for the fast and safe removal of

liquid rad ioactive contaminants. Firstly, it sequesters

metallic ions, which contaminate surfaces. Secondly, it

lifts up and firmly suspends contaminating particles.

Allowing contamination to be absorbed and then

rinsed away with water.

Radicawash, Spray Mist, 1 L bottle 005-400

Radiacwash, Bottle 1 gal* 005-100

Radiacwash, carboy w/spigot, 5 gal* 005-105

Radiacwash, drum, 55 gal* 005-155

*US gallon

Radiacwash

Radiacwash Towelettes

Radiacwash Towelettes are the most efficient and safest

way to remove rad ioactive contamination from hands

and small objects. Simply remove the towelette from the

foli packet, scrub hands thoroughly and wash the con-

tamination away with running water.

Radicawash, Towelettes 100/box 005-300

Decontamination kit

The Atomlab Decontamination Kit contains all the

equipment needed to cope with a rad ioactive spill or

routine decontamination problem in the laboratory.

The d rum serves as a container for the kit components

and as waste transfer/storage vessel.

Contents of Kit

Quantity Cat No Item

1 - 30 gallon fibre d rum

2 prs 118-125 Large coverall

2 prs 119-200 Shoe covers

2 120-530 Respirators

4 120-750 Filters

2 prs 034-005 Gloves

1 gal 005-100 Radiacwash

1 box 005-300 Radiacwash Towelettes

1 bottle 005-400 Radiacwash spray Mist, 1 Litre

10 040-108 Poly Bags

1 001-012 12” Niptong

1 ea Sponge, mop,scrub brush, pail,

rope,assorted signs

Decontamination Kit 121-180

Bartec Technologies Limited, Unit 8, Stanhope Gate, Stanhope Road, Camberley, Surrey, GU15 3DW, UK.

Tel: 01276 20842 • Fax: 01276 20891 • [email protected] • www.bartectechnologies.com

Bartec Technologies Ltd, Avenue des Mouettes 14, Bruxelles 1150, Belgium.