N14023 Addendum Four Page 1 Member: American Institute of Architects Boynton Williams & Associates 900 36 th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwa architects.com ADDENDUM NUMBER FOUR TO THE PLANS AND SPECIFICATIONS FOR MOUNTAIN VIEW GOTEBO SCHOOLS NEW ELEMENTARY & HIGH SCHOOL MOUNTAIN VIEW, OKLAHOMA ARCHITECTS PROJECT NUMBER N14023 October 15, 2015 The following items, applicable to the work designated, shall be understood to be an Addendum, and as such, shall be included in the Contract Documents. General Contractors to inform all subcontractors and suppliers of the Addendum items as appropriate or applicable to their portion of the work. CLARIFICATIONS I. Bid Package 2C Bidders: It has been determined there will be between 4,000 and 6,000 cubic yards of debris dumped at the landfill. Your bid for Bid Package 2C must include covering this debris with a minimum if three (3) feet of soil. Approximately 40% in Phase I and 60% in Phase II. II. Exterior glazing is to be front set, Interior glazing is to be center set. III. Ship ladder to be as specified in Project Manual. IV. Clarification of previous clarification made in Addendum #2: Refer Section 11 6621 Basketball Backstops, Correct paragraph 2.2/A Model Number should be 950 (bent mast) for end goals and 949 (straight mast) for side goals. SPECIFICATIONS V. Refer Section 04 2204, Masonry Veneer, Paragraph 2.1/C needs to be: Exposed Face Texture: Split Face (Color Two). Disregard reference to burnished block, there is no burnished block in this project. VI. Refer Section 04 2204, Masonry Veneer, Paragraph 2.4/C remove this paragraph. Adjusto-Flex-Mesh AF-H will not be used. Refer to Paragraph 2.5/B for Masonry Veneer Ties at Concrete Masonry Units.

DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

N14023 Addendum Four Page 1

Member: American Institute of Architects

Boynton Wil l iams & Associates900 36 t h Ave NW l Su i te 100

Norman, OK 73072

P 405.329.0423F 405.364.1439

bwaarchitects.com

ADDENDUM NUMBER FOUR TO THE PLANS AND SPECIFICATIONS

FOR MOUNTAIN VIEW – GOTEBO SCHOOLS NEW ELEMENTARY & HIGH SCHOOL

MOUNTAIN VIEW, OKLAHOMA ARCHITECT’S PROJECT NUMBER N14023

October 15, 2015 The following items, applicable to the work designated, shall be understood to be an Addendum, and as such, shall be included in the Contract Documents. General Contractors to inform all subcontractors and suppliers of the Addendum items as appropriate or applicable to their portion of the work. CLARIFICATIONS I. Bid Package 2C Bidders: It has been determined there will

be between 4,000 and 6,000 cubic yards of debris dumped at the landfill. Your bid for Bid Package 2C must include covering this debris with a minimum if three (3) feet of soil. Approximately 40% in Phase I and 60% in Phase II. 

II. Exterior glazing is to be front set, Interior glazing is to be center set.

III. Ship ladder to be as specified in Project Manual. IV. Clarification of previous clarification made in Addendum #2:

Refer Section 11 6621 Basketball Backstops, Correct paragraph 2.2/A Model Number should be 950 (bent mast) for end goals and 949 (straight mast) for side goals.

SPECIFICATIONS V. Refer Section 04 2204, Masonry Veneer, Paragraph 2.1/C

needs to be: Exposed Face Texture: Split Face (Color Two). Disregard reference to burnished block, there is no burnished block in this project.

VI. Refer Section 04 2204, Masonry Veneer, Paragraph 2.4/C remove this paragraph. Adjusto-Flex-Mesh AF-H will not be used. Refer to Paragraph 2.5/B for Masonry Veneer Ties at Concrete Masonry Units.

Page 2: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

N14023 Addendum Four Page 2

Member: American Institute of Architects

Boynton Wil l iams & Associates900 36 t h Ave NW l Su i te 100

Norman, OK 73072

P 405.329.0423F 405.364.1439

bwaarchitects.com

VII. Refer Section 07 5400, Thermoplastic Membrane Roofing, Paragraph 3.4/A, Disregard all mention of thermal barrier, there is not one.

VIII. Refer Section 08 8800, Glazing, Paragraph 2.2, Add D. Laminated Safety Glass (At Basketball Court Area)

1. General: All laminated composition glass units, whether specifically shown or specified, shall conform to manufacturer’s standards as to the maximum size for each type of glass.

2. Product Composition. a) Lite Layer 1: ¼ inch clear fully tempered glass

as specified herein. b) Interlayer: 0.06 inch PVB c) Lite Layer 2: ¼ inch clear fully tempered glass

as specified herein. 3. Compliance Standards:

a) ASTM F 1233 - Standard Test Methods for Security Glazing Materials and Systems, Class 1

b) Consumer Products Safety Commission, Title16- Code of Federal Regulations- Chapter II- Part 1201, Safety Standard for Architectural Glazing Materials, Section 1201.4, Test Procedures: Category II, 400 foot pound impact rating.

c) UL 972 – Burglary Resistive Glazing Material 4. Edges: Polish edges exposed to view. 5. Compression as required

IX. Refer Section 08 8800, Glazing, Paragraph 2.2, Add E. Low-E Insulating Glass

1. Product: “Solarban 60 (2) + Clear” glass, by PPG Industries, Inc. a) Exterior Pane: 1/4 inch (6mm) “Clear” glass, b) Air Space: 1/2 inch (13mm) air space c) Interior Pane: 1/4 inch (6mm) “Clear” glass

2. Performance Value: a) Visible Light Transmission: 70 Percent b) SHGC: 0.39 c) Shading Coefficient: 0.45 d) Outdoor Visible Light Reflectance: 11 Percent

3. Heat Transfer Coefficient: a) U-Value Winter – 0.29 b) U-Value Summer – 0.27

4. PPG Certified Fabricator only X. Refer Section 11 6123, Folding and Portable Stages,

Paragraph 2.2/A Portable Stage Units should have Gray Carpet surface.

Page 3: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

N14023 Addendum Four Page 3

Member: American Institute of Architects

Boynton Wil l iams & Associates900 36 t h Ave NW l Su i te 100

Norman, OK 73072

P 405.329.0423F 405.364.1439

bwaarchitects.com

XI. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/B, Seating Capacity: 425 home seats + 6 ADA spaces, & 378 away seats + 4 ADA spaces for a Total of 813 seats.

XII. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/C, Updated Dimensions West Side: Closed Depth = 5’-7”.

XIII. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/D, Updated Dimensions West Side: Closed Depth = 4’-11”.

XIV. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/F chair operation to be Semi-Manual.

XV. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/F/4. Chair material is intended to be All Polymer

XVI. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/J, Updated Dimensions Photography Platforms: provide two nominal 4’-0” x 6’-0” platforms with railings and steps, one on each side at positions indicated on drawings.

ARCHITECTURAL XVII. Reference Sheet 2A1a, Updated Ship Ladder to reflect

model 520 as written in specifications. Updated Construction Note #35 to reflect corrected bleacher seat numbers.

XVIII. Reference Sheet 5A1a, updated detail C/5A1a to show corrected bleacher closed depth dimensions and media platform relationship to bleachers.

XIX. Reference Sheet 5A1b, updated detail A/5A1b to show corrected bleacher closed depth dimensions and media platform relationship to bleachers.

ELECTRICAL XX. Reference Attachment D, Revised Sheet 2E2, additional

circuitry indicated. XXI. Reference Attachment E for Electrical Clarifications and

Substitutions.

END OF ADDENDUM Attachments, five: A – 1 Page B – 1 Page C – 1 Page D – 1 Page E – 5 Pages Totaling: 12 Pages

Page 4: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

ATTACHMENT A

Page 5: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

ATTACHMENT B

Page 6: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

ATTACHMENT C

Page 7: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

ATTACHMENT D

Page 8: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

Attachment E 

15-14 Mountainview-Gotebo Addendum #4 Electrical Items- Revised sheet 2E2 attached. Clarifications:

1. Specification Section 275116 – Sound Reinforcement: Requirements in this section apply only to A/V system indicated for the Gymnasium and associated equipment.

2. Sheet 2E2 - See attached revised sheet 2E2. Additional circuitry indicated.

3. Sheet 2E3 - Revised clerestory lighting circuits to “L2A-24” and “L2A-25”. (No drawing issued)

4. Sheet 2E3 - Light Fixture Schedule – Fixture Type ‘C3’ shall be the same as type ‘C3E’ without

emergency ballast.

5. Sheet 3E1 - Deleted A/V system subwoofer near southeast corner of gymnasium. (No drawing issued).

6. Sheet 4E1 - Detail ‘A’, Electrical Line Diagram – Breaker “MDP-9” shall be 3P-200A. (No drawing issued).

7. Sheet 4E2 - Panel “L2A” schedule - Added circuits for lighting changes on revised sheet 2E2 for circuits 28, 30, and 32. (No drawing issued).

Light Fixture Prior Approvals: Note: Fixtures submitted for review and not specifically noted as approved shall be considered disapproved. Where fixture series have been approved, final approval shall be obtained in the submittal process. E.C. will be responsible for meeting or exceeding requirements of the fixture utilized as the “basis of design”. The following fixtures are approved for bid as noted: Fixture Type Manufacturer Part # A LSI GA24-LED-HO-WW-UE-P12.125 Lithonia 2GTL Series Troffer Cooper 24GR-LD4-56-A125-UNV-L835-CD1-U AE LSI GA24-LED-HO-WW-UE-P12.125-EM Lithonia 2GTL Series Troffer Cooper 24GR-LD4-56-A125-UNV-EL14-L835-CD1-U AD LSI GA24-LED-HO-WW-UE-P12.125-SD50 Lithonia 2GTL Series Troffer Cooper 24GR-LD4-56-A125-UNV-L835-SD1-U ADE LSI GA24-LED-HO-WW-UE-P12.125-SD50-EM

Page 9: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

Attachment E 

Lithonia 2GTL Series Troffer Cooper 24GR-LD4-56-A125-UNV-EL14-L835-SD1-U AK LSI GA24-LED-HO-WW-UE-P12.125 Lithonia 2GTL Series Troffer Cooper 24GR-LD4-56-A125/INV-UNV- L835-CD1-U AKE LSI GA24-LED-HO-WW-UE-P12.125-EM Lithonia 2GTL Series Troffer Cooper 24GR-LD4-56-A125/INV-UNV-EL14-L835-CD1-U B LSI GA24-LED-SS-WW-UE-P12.125 Lithonia 2GTL Series Troffer Cooper 24GR-LD4-48-A125-L835-CD1-U BE LSI GA24-LED-SS-WW-UE-P12.125-EM Lithonia 2GTL Series Troffer Cooper 24GR-LD4-48-A125-EL14-L835-CD1-U C1 Vantage A6VOPLED-1-11-35K-L6060-SGC Lithonia LDN6 Series Halo PD610ED101-PDM6A835-61VCWF C2 Vantage A6VOPLED-1-15-35K-L6060-WHT Lithonia LDN6 Series Halo PD615ED101-PDM6A835-61VWB C3 PMC 6LE-MX2-013-R-40M-1-L-1-H-SOL-WL LF 5811-1SA-T-20L-8040-M-LD-US-SS C3E PMC 6LE-MX2-013-R-40M-1-L-1-H-SOL-WL with: ISI ABC-100-120 (Inverter) LF 5811-1SA-T-20L-8040-M-LD-US-SS-EM FL1 Elliptipar Style S102 Series iO Lighting 05.E.4K.90ASYM.101.1.54.X G1 ILP HB-200WLED-UNIV-4000K-FRL-WC/HB-XX-18Y-PAD

(Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets)

 

LUXdynamics LED-GYM-8-2’-UNV-0-10VDIM-850 (Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets)

Page 10: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

Attachment E 

 

      Lithonia    IBL Series 

G1E ILP HB-200WLED-UNIV-4000K-FRL-WC/HB-XX-18Y-PAD

(Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets) LUXdynamics LED-GYM-8-2’-UNV-0-10VDIM-850 (Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets)

Lithonia IBL Series  

S1      LSI      SDL‐4‐LED‐VHO‐WW‐UE 

      Lithonia    ZL2N Series   

      Cooper      4SNLED‐LD4‐50SL‐LW‐UNV‐L835‐CD1‐U 

 

S1E      Cooper      4SNLED‐LD4‐50SL‐LW‐UNV‐EL14W‐L835‐CD1‐U   

 

UC4      Rayon      RULA‐29‐10‐30K‐WH 

      FeelUX      TUNELight2 Series 

      Halo      HU1036D930P 

 

V1      Bartco      BSS205 Series 

      Shaper      600‐36‐W‐L3/835‐UNV‐NA 

 

WP1 Lithonia WSR LED Series McGraw Edison ISC-F02-LED-E1-BL4-BK  

WP1E Lithonia WSR LED Series McGraw Edison ISC-F02-LED-E1-BL4-BK-BBB-XX  

WP2 Mule EOE-BB-15L3-BLACK-LT

Signtex MOE Series

Page 11: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

Attachment E 

WS PMC SS3075-LED-D-W/X-3500K-L-X-WOA-WHT-20V

Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (PMC)

LumenWerx V3PERD-HLO-LED-80-500-N/A-35-4-NA-UNV-NDM-1-XX-W

Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (LUMENWERX)

Focal Point Trace FTRL Series

WW LSI S-4-LED-VHO-WW-UE-SD50

Focal Point Trace FTRL Series

Cooper 4SNLED-LD4-64HL-UNV-L835-SD1-U

WW2 Forum SAUD-43-65LED35/65LED35-OU/SAT-WBX4-UNV-XX

Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (Forum)

Focal Point Seem 2 LED Series – FSM2LW

Gammalux GB35B2-1/SOLED35-UNIV-DVR-4IN-WM-APL/ASLMD-CCM-2CKT

WW2E Forum SAUD-43-65LED35/65LED35-OU/SAT-WBX4-UNV-XX

Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (Forum)

Focal Point Seem 2 LED Series – FSM2LW

Gammalux GB35B2-1/SOLED35-UNIV-DVR-4IN-WM-APL/ASLMD-CCM-2CKT-EMERG

X1 Mule ELX-X-B-RC-U-BA

Lithonia EDG/EDGR Series

Surelites EUX7R

X2 Mule MXBRU-SD-WG2

Lithonia LXC Series w/ Wire guard

Page 12: DDENDUM UMBER OUR TO THE PLANS AND SPECIFICATIONS … Addendum Four... · 900 36th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com ADDENDUM NUMBER

Attachment E 

Surelites LPX7SD

EM Mule MRD-HO-6-54-LED3W-SD

Lithonia ELM Series

Surelites LEMSD