L E N M 0DA
+DB
L E N M 0DA
+DB
*No Maintained output
CMS (DBC905C) WIELAND (DBC905W) WAGO (DBC905WA)*
NL NL
L E N 0DA
+DB
NL
X 9 X 9 X 9
www.lighting.philips.com/dynalite
DBC905
X 4
X 9
X 4
416 mm (16.38 in)
35
mm
(1.
38
in)
189 mm (7.44 in)
397 mm (15.63 in)
96
mm
(3
.78
in)
Signal Dimmer Controller
Installation Instructions
Instructions d’installation
Installationsanweisungen
Instrucciones de instalación
Istruzioni per l’installazione
Installatie-instructies
インストール手順安装指示
50° C (122° F)
0° C (32° F)
≤95%
Devices must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Les appareils doivent être installés par un électricien diplômé conformément à tous les codes et réglementations électriques et de construction nationaux et locaux.
Die Geräte sind von einem qualifizierten Elektriker in Übereinstimmung mit allen geltenden Vorschriften zu installieren.
Los dispositivos deben ser instalados por un electricista calificado y cumpliendo todas las normas y regulaciones, tanto nacionales como locales, sobre instalaciones eléctricas y obras.
I dispositivi devono essere installati da un elettricista qualificato in conformità con le norme locali e nazionali vigenti in materia di costruzioni edilizie e installazione di impianti elettrici.
De apparaten moeten worden aangebracht door een gekwalificeerde elektricien en in overeenstemming met alle nationale en plaatselijke elektriciteits- en bouwvoorschriften.
装置を取り付ける際は、資格のある電気技師に依頼し、 国および地域の電気および建設に関するすべての法令に 従ってください。
根据国家/地区及当地的电气与建筑规范和法规,该设备必须由有资质的电工进行安装。
.
2
2
2 A 2 A
5 A
2 A 2 A 2 A
5 A
2 A 2 A 2 A
5 A 15 A
2 A
Output Ratings/Channel (CH)
General Use
Load Type CH1-CH9
5 A, 230 V
2 A, 230 V
100 A
Maintained
5 A, 230 V
Electronic Ballast
Inrush Current
DALIAddress-able andBroadcast
Control Channel Ratings
DSI
1-10 V
≤ 5/CH
12.5 V
Guaranteed 15 mAMaximum 250 mA
Insulation: basic
Sink 10 mA
Source 10 mA
Driver dependent
≤ 45
≤ 5/CH ≤ 45
Output Ratings/GroupCH1-CH3 ≤ 5 ACH4-CH6 ≤ 5 ACH7-CH9 + Maintained output ≤ 5 ADBC905 ≤ 15 A
IEC Pollution Degree II
1 A
1 B
3
230 V 20 A
µP
ENL Switch 1 Switch 2 Switch 3 Switch 41 2 3 4G
ND
SH
LD
GN
DD
+D
-+
12 V
AU
X
D+
D-
RS-485RJ12Local DyNet
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9
T 6.3 A H
FloorDyNet RS-485
SELV/Class 2230 V 16 A
12 V 400 mA
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
DA
LI D
SI 1
-10
V
Ma
inta
ine
d
IEC Overvoltage Category III
3
5
4
230 V
T6-3 AH
Floor DyNet RS-485
CH
1
CO
M
CH
2
CH
3
CO
M
CH
4
CH
5
CO
M
CH
6
CH
7
CO
M
CH
8
SH
LD D+
D-
SH
LD
GN
D D+
D-
+12V
AU
X
+12V
RJ12
+12V D
-D
+G
ND
GN
D
GND AUX
< 20 m
LOCAL DyNet
≤ 2 A ≤ 2 A
Floor DyNet RS-485
DyNet RS-485
0.56 Nm5.1 Lb-in
≤ 2.5 mm2
12+ AWG
≤ 2 A
6
9
This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.
AZZ 368 0519 R13
© 2019 Signify Holding. All rights reserved. Specifications are subject to change without notice. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners.