This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Data Sheet DMM-4026-B-R
Microphone Specifications
Parameters Condition Values Units
Directivity Omnidirectional
Sensitivity
1 kHz @ 50cm with 94 dB source
0 dB=1V/Pa -26±1 dB
Data Format 1/2 Cycle PDM
Rated Voltage - 1.8 VDC
Operating Voltage Range - 1.5 to 3.6 VDC
Current Draw Full Power Mode 820 ~ 1000 µA
Low Power Mode 400 ~ 450 µA
Signal-to-Noise Ratio (1kHz, 94 dB input, A-weighted)
Full Power Mode 63 dB
Low Power Mode 61 dB
Frequency Range 20~18,000 Hz
Total Harmonic Distortion (typical) 94 dB @ 50cm, 1 kHz acoustic source 0.5% -
Soldering Methods Reflow Solder See page 6
Acoustic Overload Point (AOP)
Full Power Mode SPL @ 50cm with 10% THD @ 1 kHz
123 dB
Low Power Mode SPL @ 50cm with 10% THD @ 1 kHz
120 dB
Environmental Compliances RoHS/Halogen Free
Power Supply Rejection 100 mVpp Square Wave @ 217 Hz, A-weighted -86 dBFS
Weight <0.3 Grams
Load Capacitance 140 pF
Max Voltage on any Pin 4 VDC
Maximum SPL Before Damage (Source 50cm from microphone) 160 dB
Max Mechanical Shock 10,000 Gs
Max Vibration Pre-MIL-STD-883 Method 2007, Test Condition B
Operating Temperature (VDD <3.0V) -40 ~ +100 °C
Operating Temperature (VDD >3.0V) -40 ~ +70 °C
Storage Temperature -40 ~ +125 °C
MSL (Moisture Sensitivity Level)* 1 -
*MSL level dependent on product remaining in sealed packaging until use
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Operational Settings
Parameters Condition Values Units
Clock Frequency
Sleep Mode 0 ~ 250 kHz
Low Power Mode 351 ~ 800 kHz
Full Power Mode 1.03 ~ 4.80 MHz
Duty Cycle For fCLK ≤ 2.4 MHz the duty cycle must be
in the range of 40 ~ 60% and for fCLK > 2.4 MHz the duty cycle must be 50% 40 ~ 60 %
Logic Input High - 0.75*VDD ~ VDD + 0.3V
Logic Input Low - -0.3 ~ 0.25*VDD
Logic Output High - 0.75*VDD ~ VDD + 0.3V
Logic Output Low - -0.3 ~ 0.25*VDD
Timing Characteristics
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Measurement Method
Measurement Interface Circuit
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Typical Frequency Response
Frequency Response Mask (100% Pass/Fail Test for Microphones)
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Total Harmonic Distortion + Noise versus SPL Input (with acoustic source at 50cm)
Microphone Output versus SPL Input (with acoustic source at 50cm)
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Recommended Soldering Procedure
Reliability Testing Type of Test Test Specifications
Simulated Reflow (Without Solder)
Samples for qualification testing require 3 passes 260±5 ℃ reflow solder profiles. 2 hours of setting time is required between each reflow profile test.
Static Humidity
Precondition at +25℃ for 1 hour. Expose to +85℃ with 85% relative humidity for 1000 hours. Dry at room ambient for 3±1 hour before taking final measurement.
Temperature Shock
Each cycle shall consist of 30 minutes at -40℃, 30 minutes at +125℃ with 5 minutes transition time. Test duration is for 30 cycles, starting from cold to hot temperature.
ESD Sensitivity
Perform ESD sensitivity threshold measurements for each contact according to MIL-STD-883G, Method 3015.7 for Human Body Model. Identify the ESD threshold levels indicating passage of 8000V Human Body Model.
Vibration Test
Vibrate randomly along three perpendicular directions for 30 minutes in each direction, 4 cycles from 20~2000 Hz with a peak acceleration of 20 Gs.
Shock Test Subject samples to half-sine shock pulses (3000±15% Gs for 0.3ms) in each direction, for a total of 18 shocks.
Drop Test Drop samples from 1.5m height onto a steel surface, total 18 times and inspected for mechanical damage.
Operation Life Subject samples to +125℃ for 168 hours under full maximum rated voltage.
Microphone frequency response and sensitivity shall not deviate more than ±3 dB.
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Dimensions
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Suggested Pickup Tool Location and Land Pattern*
*This land pattern is advisory only and its use or adaptation is entirely voluntary. PUI Audio disclaims all liability of any kind associated with the use, application, or
adaptation of this land pattern.
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Packaging
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Packaging (continued)
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Packaging (continued)
This document contains data proprietary to PUI Audio Inc. Any use or reproduction, in any form, without prior written permission of PUI Audio Inc. is prohibited.
©2019, PUI Audio Inc.
PUI Audio, Inc., 3541 Stop Eight Road, Dayton, OH 45414 Tel: (937) 415-5901 Fax: (937) 415-5925
Specifications Revisions
Revision Description Date
- Released from Engineering 10/31/2019
Note:
1. Unless otherwise specified: A. All dimensions are in millimeters. B. Default tolerances are ±0.5mm and angles are ±3°.
2. Specifications subject to change or withdrawal without notice.