6
DATA SHEET Elegant Net 19inch Free Standing Rack Cabinet H:42U W:600 x D:600 Removable and lockable side panels Optional fan-unit into the roof or 19inch rack mount type fan unit Flat-packed construction Vertical mounting rails are adjustable throughout the entire depth of the cabinet. High load carrying capacity ( standard 800kg & Modified structure 1500kg ) With 1.5mm thickness silk-screen mounting rails. Temprered safety glass front door, t:4mm Sheet steel rear door Perforated front and rear doors are avaliable upon the request Günko Endüstriyel Sistemler San.Tic.Ltd.Şti. www.gunko.com.tr [email protected] / [email protected] Technical Data H:1955mm W:600mm D:600mm (Check 2nd page for different height options ) 42U RAL 9005 Black color = ELGN 42U 6060 BL 111 or RAL 7035 L.gray color = ELGN 42U 6060 LG 111 In accordance with the standard EN 61587-1: 2012 / EN 61010-1 / IEC 60917- IEC 60297 ISO9001-2015 TS EN 61587-1 :2012, 5.2.1 and 5.2.2 CE According the IEC/ISO 17050 EN 62208:2011 & EN 60335-1 Dimensions HxWxD in mm Height in U Color Grounding countinuity Standards List Code : ELGN 42U 6060 CC 111 Mechanical Characteristics Sheet Steel, DIN EN 10130-99 / DC-01 6112 / DC-7122 1870,10 1955 800kg / 1763lbs (Modified structure up to 1500kg / 3306.93Ibs) IP20 Material Inside height in mm Outside height in mm Load Carrying Capacity IP rating We are responding the needs of users with choice of 10 different height dimensions. Height : 12U - 16U20U22U26U32U36U42U45U-47U Width : 600mm Depth : 600mm

DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

DATA SHEET

Elegant Net 19inch Free Standing Rack Cabinet

H:42U W:600 x D:600

• Removable and lockable side panels

• Optional fan-unit into the roof or 19inch rack mount type fan unit

• Flat-packed construction

• Vertical mounting rails are adjustable throughout the entire depth of the

cabinet.

• High load carrying capacity ( standard 800kg & Modified structure 1500kg )

• With 1.5mm thickness silk-screen mounting rails.

• Temprered safety glass front door, t:4mm

• Sheet steel rear door• Perforated front and rear doors are avaliable upon the request

Günko Endüstriyel Sistemler San.Tic.Ltd.Şti.www.gunko.com.tr

[email protected] / [email protected]

Technical Data

H:1955mm W:600mm D:600mm (Check 2nd page for different height options )

42URAL 9005 Black color = ELGN 42U 6060 BL 111 or RAL 7035 L.gray color = ELGN 42U 6060 LG 111 In accordance with the standard EN 61587-1: 2012 / EN 61010-1 / IEC 60917- IEC 60297

ISO9001-2015

TS EN 61587-1 :2012, 5.2.1 and 5.2.2

CE According the IEC/ISO 17050 – EN 62208:2011 & EN 60335-1

Dimensions HxWxD in mm

Height in U

Color

Grounding countinuity

Standards

List Code : ELGN 42U 6060 CC 111

Mechanical Characteristics

Sheet Steel, DIN EN 10130-99 / DC-01 6112 / DC-7122

1870,10

1955

800kg / 1763lbs (Modified structure up to 1500kg / 3306.93Ibs)

IP20

Material

Inside height in mm

Outside height in mm

Load Carrying Capacity

IP rating

We are responding the needs of users with choice of 10 different height dimensions.

Height : 12U - 16U–20U–22U–26U–32U–36U–42U–45U-47U

Width : 600mm

Depth : 600mm

Page 2: DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

DATA SHEET

Günko Endüstriyel Sistemler San.Tic.Ltd.Şti.www.gunko.com.tr

[email protected] / [email protected]

Page 3: DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

DATA SHEET

Günko Endüstriyel Sistemler San.Tic.Ltd.Şti.www.gunko.com.tr

[email protected] / [email protected]

Explode View

Page 4: DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

DATA SHEET

Günko Endüstriyel Sistemler San.Tic.Ltd.Şti.www.gunko.com.tr

[email protected] / [email protected]

VENTILATION OPTIONS

Quick-change fan trays that can be accessed without removing the cabling or the device from the rack

Elegant-Net ; Roof panel has been designed for ventilation module which can be detached by removing 4 pcs screws from the top in

case of maintenance or replacement needs.

STANDARDS : EMC EN55032:2015 & LVD IEC 62368-1 :2018

Power Characteristics

Voltage range

Freq Hz

Current (A)

Power W

Speed RPM

Noise level in (dB)

Air flow M3/Hr & CFM

Compatible Fan Units

PA CC ELG FN 02

PA CC ELG FN 04

PA CC ELG FN T2

PA CC ELG FN T4

PA CC ELG FN DT2

PA CC ELG FN DT4

Ventilation unit with 2 Fans+with On/Off switch control

Ventilation unit with 4 Fans+with On/Off switch control

Ventilation unit with 2 Fans+Analog Thermostat

Ventilation unit with 4 Fans+Analog Thermostat

Ventilation unit with 2 Fans+Digital Thermostat

Ventilation unit with 4 Fans+Digital Thermostat

SHALVES

Front view

Fixed & Sliding shelf

installation

Rear view

Fixed & Sliding shelf

installation

FIXED /SLIDING SHELVES

LOAD CARRYING

CAPACITIES • Fixed shelf : 50kg / 110lbs

• Sliding shelf : 25kg / 55 lbs

Compatible Shalves

PA CC RK SR 60

PA CC RK HR 60

1/2U Fixed Shelf - 600 mm Depth Cabinets

Sliding Shelf - 600 mm Depth Cabinets

Note: compatible with all 19inch rack mount Fan units

Note: compatible with all cantilever shalves

220/240

50/60

0,14A

22

2700/3000

40/47dB

133/162 & 82/95

Page 5: DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

DATA SHEET

Günko Endüstriyel Sistemler San.Tic.Ltd.Şti.www.gunko.com.tr

[email protected] / [email protected]

TECHNICAL SPECIFICATIONS

PROTECTION INDEX

• IP20 According to EN 61587-1 / IEC 60529

• IP20 :Rigid test rod diameter of 2.5 mm, 100 mm long (as specified by the standard) is pushed against any openings of the

enclosure with the force of 3N

MECHANICAL PERFORAMANCE

• EN 61587-1 5.2.1 / 5.2.3

• Stiffness test (Performance level SL6)

• Dynamic mechanical load test (Performance level DL4)

• Resonance point detection test IEC 60068-2-6

• Vibration test (Sinus-IEC 60068-2-6)

• Shock test IEC 60068-2-27)

• Impact test IEC 60068-2-75 (Performance level K2)

• Permissible load carrying capacity : 800kg

CLIMATIC TESTS (Performance level C2)

• Cold (IEC 60068-2-1) Temperature of the exposure: -25°C +/-3°C

• Dry heat (IEC 60068-2-2) Temperature of the exposure: +70°C +/-2°C

• Damp heat cyclic (IEC 60068-2-30)

INDUSTRIAL ATMOSPHERE (Performance level A3)

• Salt mist test (IEC 60068-2-11

• Sulphur dioxide test and hydrogen sulphide test IEC 60068-2-42, IEC 60068-2-43, IEC 60068-2-49

GROUNDING CONTINUITY

EN 61587-1 / EN 61010-1

• The continuity of the protection circuit is in accordance with the standard regulations. The measured resistance was less

than 0.1 Ohm.

STANDARDS

1. ISO9001-2008 Quality management system must be used in the production of 19” Rack cabinets

2. 19” Rack Cabinets must have a TSE Certificate EN-61587-1 , IEC60917 – IEC 60297 standards

3. In addition, all of the main and auxiliary materials used in the manufacturing process must comply with the following

standards

SHEET METAL: TS EN ISO 9001:2008; TS EN 10130 :2006; DIN EN 1030- EQV; BS EN 1030-EQV; NF A36-401.

ELECTROSTATIC POWDER PAINT: ISO 9001:2015 ASTM D523; ASTM D2794; DIN EN ISO 2811-1; ASTM D1186/D1400;

Ral:9005 or Ral:7035.

VENTILATION UNITS ( Fan Unit ) “EMC EN55032:2015 & LVD IEC 62368-1 :2018

TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 – 2 : Glass, Tempered, secure ” Mechanical strength test result: Bending

strength minimum 120 N/ mm²

CONNECTION COMPONENTS (screw, nut, washer etc.)“ TS EN ISO 7045; TS EN ISO 4032; RoHS IEC 62321 ”

WHEEL SET “ TS EN 12532 , TS EN 12533 , RoHS IEC 62321:2008”

LOCKS SYSTEMS “DIN-EN ISO 1043-1 PA6 GFR 30; DIN-EN 1774-ZnAl4Cu1.

Page 6: DATA SHEET · 2021. 3. 12. · TEMPERED SAFETY GLASS “ ISO 9001 , EN 12150 –2 : Glass, Tempered, secure ”Mechanical strength test result: Bending strength minimum 120 N/ mm²

DATA SHEET

Günko Endüstriyel Sistemler San.Tic.Ltd.Şti.www.gunko.com.tr

[email protected] / [email protected]

1. Dimensions must comply with IEC60297 standards. Cabinet must be height (12U,16U,20U,22U,26U,32U,36U,42U,45U,47U )

• Width : 600mm

• Depth : 600mm

2. Main frame and profile structures must be manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 /

5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Dynamic load, vibration and mechanical impact (IEC

60068-2-6 , IEC 60068-2-27) test results must be certified by TSE.

3. Main profile structure must be a structure that would increase mechanical resistance with aesthetic appearance, folded with an

angle of 45 degree and must consist of 6 bending. 2 front and rear frames must be with welded and framed monoblock structure.

4. Bottom plate must have cable access that would block dust inlet. Bottom case must have sliding cable entry paths with

dimensions 300x125mm ( 1pcs for 600x600mm )

5. Rear door must be full lenght solid metal with single Barrel lock mechanism, Standard rear door configuration; single opening

door for widht:600mm rack cabinet

6. Side panels must have a structure that can be openable and and removable by 2 sliding latch locks and one barrel lock with key

7. Front door glass structure must be tempered,anti-static,secure glass with 4mm thickness according to EN 12150-1:2008

standard. front door must have left and right metal frames structure with high density silicone and screws and nuts , structure that

open 135 degrees , removable by spring hinge , lockable with swing handle lock.

8. To provide high resistance to impacts, cabinets must be coated by RAL 9005 or RAL 7035 Electrostatic powder coat to meet ISO

8130 and ASTM D 523 / 2794 standards and test result reports must be certificated. On flat metal surfaces, there must be 85±5

micron paint thickness and must be tested according to ASTM D2794; DIN EN ISO 2811-1; ASTM D1186/D1400 Ral:9005 or

Ral:7035.

9. 4pcs Lateral extension parts must have a structure that would increase resistance and strength of cabinet between front and

rear monoblock frames.

10.Roof panel must be compatible with 2 & 4 way cooling unit installation, + 1 pcs M-joint type cable entry with dimensions

300x56mm

11. Vertical mounting rails are adjustable throughout the entire depth of the cabinet and thickness must be 1.5mm, Silk-screened

mounting rails must be provide ability to count U- Marking from top to down & down to up for easy device installation

12.Cabinet locks: all locks used in cabinets must have the same coded-key and all covers of cabinets must have a lockable

structure

13. Fan units must be with the standards ISO 9001 :2015 , CE ( 89/336/EEC EMC EN55032:2015 LVD IEC 62368-1 :2018 ) , RoHS

” , Noise 40/47dB , Air Flow M3/Hr 133/162 CFM 82/95.

14. All metal components in cabinets must be connected to one another electrically and grounding resistance must be maximum

0,1 ohm according to IEC 61010-1 / 6.5.1.3 standard. All proposed products must be tested to meet this standard and their results

must be certificated by TSE.

TECHNICAL SPECIFICATIONS