1
Visit www.panduit.com for more information.2
High-Speed Fiber Cabling SystemsPanduit provides high bandwidth and mission-critical physical infrastructures in data center, enterprise, and campus networks with
comprehensive fiber optic systems that deliver high performance, reliability, and scalability. The deployment of high-speed cabling
systems has been increasing rapidly as data centers enable their physical infrastructure with 10 Gb/s capacity to support server
virtualization, I/O consolidation, and convergence of backbone applications.
Structured Cabling InfrastructureA properly designed and implemented cabling infrastructure is a fundamental asset of every business. Carefully planning a
structured cabling solution facilitates the delivery of new services, lowers network maintenance costs, and increases productivity.
New high-bandwidth applications enable organizations to better fulfill their need for productivity and innovation in a rapidly
changing world.
Innovative Data Center Infrastructure SolutionsPanduit provides a comprehensive, intelligent data center offering that supports best practice methodologies. Our data center
solutions enable physical to logical architecture integration, and deliver robust, scalable physical infrastructures that address:
• Visibility and control for managing and automating real-time data processes and documentation
• Convergence of new technologies and high-speed data applications
• Operational efficiency through process improvement and IT initiatives, such as cooling conservation through energy efficient data cabinets
• Capacity management for greater real estate utilization
• Modular pods designed to support high-density applications and provide consistent, reliable deployments while lowering infrastructure risk and costs
Panduit’s intelligent data center solutions facilitate faster implementation and simple specification, streamlining the process of
designing, specifying, installing, and managing the increasingly complex physical infrastructure necessary to optimize your data
center. Panduit knows the data center space intimately. We help you discover tangible infrastructure and business process
improvements that increase functionality, interoperability, and manageability of mission-critical operations across your
entire organization.
High Speed Data Transport SolutionsHigh Speed Data Transport (HSDT) Solutions are a set of complementary copper and optical fiber technologies for mission critical
data center applications, spanning storage and compute requirements and leading edge architectures. Based on an understanding
of today’s vital business and technology challenges and how they impact data centers, Panduit has created best-in-class physical
infrastructure solutions for HSDT. Panduit provides the broadest offering of end-to-end HSDT solutions supporting all data center
architectures. Designed for high-density/high-speed applications, Panduit HSDT solutions are backed by comprehensive research
and development programs to ensure high network performance, systems reliability, energy efficiencies, and seamless integration.
PanNet ® System WarrantyAll Panduit channels are field tested by Panduit Certified Installers (PCI) using industry standard hand-held devices which provide
verified network performance, and ensures your network operates at optimal performance.
Panduit ® Opti-Core ® Fiber Optic Cable
3
Cable Fire Ratings Reference GuideCable fire ratings need to be considered when specifying cabling infrastructure to ensure local building codes are met. The below
rating guide provides the information needed to determine which rating is appropriate for different installation environments.
Plenum Rated Cable (OFNP)A Plenum Rating (OFNP) signifies cable that has passed stringent burn testing and is suitable for installation into air plenum
spaces. OFNP cables have fire-resistance and low smoke production characteristics. They can be installed in ducts, plenums, and
other spaces used for building airflow. This is the highest fire rating fiber cable and no other cable types can be used as substitutes.
Plenum Rated Cable (OFCP)A Plenum Rating (OFCP) differs from OFNP in that the cable contains metallic elements, typically armor, and therefore, conducts
electricity. All other aspects of this rating are the same as OFNP.
Riser Rated Cable (OFNR)A Riser Rating (OFNR) is commonly required when cables are run between floors through open vertical shafts. OFNR cables are
used in Riser areas which are building vertical shafts or runs from one floor to another floor. OFNR cables cannot be installed in
plenum areas since they do not have the required smoke rating as plenum rated cables. OFNP plenum cables can be used as
substitutes for OFNR Riser cables.
Riser Rated Cable (OFCR)A Riser Rating (OFCR) differs from OFNR in that the cable contains metallic elements, such as a layer of armor, and therefore,
conducts electricity. All other aspects of this rating are the same as OFNR.
Low Smoke Zero Halogen (LSZH) A Low Smoke Zero Halogen Rating (LSZH) is sometimes referred to as low toxicity cable. When burned, PVC-based cables
produce a cloud of toxic smoke containing corrosive compounds such as hydrochloric acid. The LSZH cables do not contain the
Halogen type compounds that form these toxic substances. Smoke emitted from burning LSZH cables do not produce the toxic
halogen-based gasses previously mentioned. LSZH ratings are expressed as OFN-LS or OFNR-LS if the cable also meets the
requirements of a OFNR rated cable.
Non-Flame Rated Outside Plant (OSP) cables are intended for outdoor use only. Typically, these cables are constructed using varying densities of
Polyethylene, (PE) in the outer jacket, and perhaps in other OSP cable components. Because cables without flame ratings do not
contain flame suppressants and emit noxious gasses when burned, building codes often restrict the distance installers are
permitted to route inside buildings before termination.
Panduit® Opti-Core® Fiber Optic Cable
Visit www.panduit.com for more information.4
Fiber Cable for Americas(North America and Latin America)
Opti-Core ® Interconnect CableUsed in interconnect, horizontal installations, routing in tight spaces such as panels, cable trays, and fiber-to-the-desk (FTTD) applications.
1
F
2
S
3
I
4
P
5
5
6
0
7
2
8
Y
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM43 – Cable Construction I = Interconnect cable
4 – Flame Rating P = Plenum R = Riser
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 6.25//125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber8 – RoHS Y = RoHs compliant
Character
Example
Strength members
Outer jacket
Optical fiber
900µm buffer
Strength members
Optical fiber
900µm buffer
Outer jacket
Opti-Core ® Indoor Distribution CableFor indoor use in intra-building backbone and horizontal installations.
1
F
2
S
3
D
4
P
5
5
6
0
7
6
8
Y
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM43 – Cable Construction D = Distribution cable
4 – Flame/Smoke Rating R = Riser (OFNR) P = Plenum (OFNP)5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 06 = 6-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber 48 = 48-fiber 72 = 72-fiber
8 – RoHS Y = RoHS compliant
Character
Example
5
Fiber Cable for Americas(North America and Latin America)
Opti-Core ® Indoor/Outdoor All-Dielectric Cable with Tight Buffered FibersThese cables provide an effective solution for inter-building and building transition applications.
1
F
2
S
3
K
4
R
5
5
6
1
7
2
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM43 – Cable Construction K = Indoor/outdoor tight buffered unarmored4 – Flame/Smoke Rating R = Riser P = Plenum
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 6.25//125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber 24 = 24-fiber
36 = 36-fiber48 = 48-fiber72 = 72-fiber96 = 96-fiber1A = 144-fiber (Riser only)
Character
Example
Outer jacket
Aramidstrength members
Optical fiber
Buffer
Opti-Core ® Indoor/Outdoor All-Dielectric Cable Allows installation using loose tube cable methods within buildings and outdoor environments for transitional aerial, duct applications, and entrance facilities.
1
F
2
S
3
C
4
P
5
5
6
0
7
6
8
Y
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM43 – Cable Construction C = Indoor/outdoor central tube (up to 12 fibers) N = Indoor/outdoor stranded tube (24 fibers and greater)
4 – Flame Rating R = Riser P = Plenum5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 06 = 6-fiber 12 = 12-fiber 24 = 24 fiber 36 = 36 fiber 48 = 48 fiber 72 =72 fiber 96 = 96 fiber 1A = 144 fiber
8 – RoHS Y = RoHS compliant
Character
Example
Water-blockingstrength members
Dry-blocked buffer tube
Outer strengthmembers
Flameretardantouter jacket
Rip cord
250µm optical fibers(up to 12)
Visit www.panduit.com for more information.6
Cable outer jacket
Strength members
Optical fiber
Buffer
Overlaid jacket
Opti-Core ® Indoor/Outdoor Interlocking Armored Cable with Tight Buffered FibersFor use indoors and outdoors. Interlocking aluminum armor eliminates the need for inner duct or conduit.
Fiber Cable for Americas(North America and Latin America)
Aluminum interlockingarmor
Opti-Core ® Indoor Interlocking Armored Cable
Opti-Core ® Interlocking Armored Cable Offering
Used in intrabuilding backbone, building backbone, and horizontal installations and harsh environments.
Cable outer jacket
Strength members
Optical fiber
900µm buffer
Overlaid jacket
Aluminum interlocking armor
7
Outer jacket
Rip cord
Flame retardant jacket
Overlaidjacket
Opti-Core ® Indoor/Outdoor Interlocking Armored CableFor use indoor and outdoors. Central loose tube constructions. Interlocking aluminum armor eliminates the need for inner duct or conduit.
1
F
2
S
3
G
4
P
5
5
6
0
7
6
8
Y
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM4
3 – Cable Construction G = Indoor/outdoor interlocking armored central tube (up to 12 fibers) M = Indoor/outdoor interlocking armored stranded tube (24 fibers and greater) L = Indoor/outdoor tight buffered P = Indoor interlocking armored
4 – Flame Rating R = Riser P = Plenum
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber 48 = 48-fiber 72 = 72 fiber 96 = 96-fiber 1A = 144-fiber
8 – RoHS Y = RoHS compliant
Character
Example
Fiber Cable for Americas(North America and Latin America)
Optical fiber
Water-blockingstrength member
Dry-blocked buffer tube containing up to(12) 250µm fibers
Visit www.panduit.com for more information.8
Fiber Cable for Americas(North America and Latin America)
1
F
2
S
3
A
4
D
5
5
6
1
7
2
8
–
9
B
10
L
1 and 2 – Fiber Product FS = OM1, OM2, OS2 FO = OM3, OM43 – Cable Construction A = Dielectric Conduited Distribution (indoor4 – Flame/Smoke Rating D = Dual rated riser (OFNR) and low smoke zero halogen
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 6.25/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber
8 – Dash9 and 10 – Jacket color BL = Black
Character
Example
Cable outer jacket
Aramidstrength members
Optical fiber
Buffer
Dielectricconduit
Opti-Core ® Dielectric Conduited Fiber (DCF) Optic CableFor indoor use in intra-building backbone and horizontal installations.
Dry-blocked buffer tube containing6 or 12 fibers
Rip cord
Outer jacket Water-blocking tape
Central strengthmember
Opti-Core ® Gel-Free All-Dielectric Outside Plant CableFor use outdoors in aerial and duct applications.
1
F
2
O
3
T
4
N
5
X
6
0
7
6
Character
Example
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM4
3 – Cable Construction T = Outside plant stranded cable (all fiber counts)4 – Flame Rating N = Non-rated
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 6.25//125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 06 = 6-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber 48 = 48-fiber 72 = 72-fiber 96 = 96-fiber 1A = 144-fiber
Filler tube
Outer strengthmembers
9
Fiber Cable for Americas(North America and Latin America)
Opti-Core ® Gel-Free Armored Outside Plant CableCorrugated steel armor provides superior crush resistance for extended durability in direct burial applications.
1
F
2
O
3
W
4
N
5
X
6
0
7
6
1 and 2 – Fiber Product FS = Fiber – OM1, OM2, OS2 FO = Fiber – OM3, OM4
3 – Cable Construction W = Outside plant armored stranded cable (all fiber counts)4 – Flame/Smoke Rating N = Non-rated
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 6.25/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 06 = 6-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber 48 = 48-fiber 72 = 72-fiber 96 = 96-fiber 1A = 144-fiber
Character
Example
Dry-blocked buffer tube containing6 or 12 fibers
Rip cord
Outer jacket
Corrugatedsteel armor
Water-blockingtape
Outerstrength members
Filler tube
Centralstrength member
Visit www.panduit.com for more information.10
Opti-Core ® Indoor Distribution CableFor indoor use in intrabuilding backbone and horizontal installations.
Fibre Cable for EMEA(Europe, Middle East, and Africa)
1
F
2
P
3
D
4
L
5
9
6
2
7
4
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM4
3 – Cable Construction D = Distribution cable4 – Flame/Smoke Rating L = Low smoke zero halogen (LSZH)
5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 04 = 4-fibre 08 = 8-fibre 12 = 12-fibre 24 = 24-fibre 36 = 36-fibre 72 = 72-fibre
Character
Example
Strength members
Outer jacket
Optical fibre
900µm Buffer
1
F
2
P
3
I
4
L
5
5
6
0
7
2
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM43 – Cable Construction I = Interconnect zip-cord cable
4 – Flame Rating L = Low smoke zero halogen (LSZH)
5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 02 = 2-fibre
Character
Example
Opti-Core ® Interconnect Cable Used in interconnect, horizontal installations, and for routing in tight spaces such as panels, cable trays, and fibre-to-the-desk (FTTD) applications.
Cable print legend
900µm Buffer
Outerjacket
Optical fibre
900µm Buffer Strengthmembers
11
Opti-Core ® Indoor/Outdoor All-Dielectric Cable with Tight Buffered FibresFor indoor and outdoor use.
1
F
2
P
3
K
4
L
5
5
6
1
7
2
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM43 – Cable Construction K = Indoor/outdoor tight buffered unarmored4 – Flame Rating L – Low smoke zero halogen
5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 02 = 2-fibre 04 = 4-fibre 06 = 6-fibre 08 = 8-fibre 12 = 12-fibre 24 = 24-fibre
36 = 36-fibre48 = 48-fibre72 = 72-fibre96 = 96-fibre
Character
Example
Fibre Cable for EMEA (Europe, Middle East, and Africa)
Strength members
Outer jacket
Optical fibre900µm Buffer
1
F
2
P
3
N
4
L
5
5
6
3
7
6
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM4
3 – Cable Construction C = Indoor/outdoor central tube (up to 24 fibres) N = Indoor/outdoor stranded tube (36 fibres and greater)4 – Flame Rating L = Low smoke zero halogen (LSZH)
5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 04 = 4-fibre 08 = 8-fibre 12 = 12-fibre 24 = 24-fibre 36 = 36-fibre 48 = 48-fibre 72 = 72-fibre 96 = 96-fibre
Character
Example
Water-blocking tape
Outer strength members
Rip cord
4, 8, or 12Fibre, gel-filled, buffer tube sub-unit
1 to 5 Filler tubes
Opti-Core ® Indoor/Outdoor All-Dielectric CableFor use indoor or outdoors. Central and stranded loose tube constructions are all-dielectric.
Central strength member
Flameretardant tape
Flame retardant outer jacket
Visit www.panduit.com for more information.12
Fibre Cable for EMEA(Europe, Middle East, and Africa)
Opti-Core ® Dielectric Conduited (DCF) Fibre Optic CableFor indoor use in intrabuilding backbone and horizontal installations. Cable outer
jacketAramidstrength members
Optical fibre
Buffer
Dielectricconduit
1
F
2
S
3
A
4
D
5
5
6
1
7
2
8
–
9
B
10
L
1 and 2 – Fibre FS= OM1, OM2, OS2 FO= OM3, OM43 – Cable Construction A = Dielectric conduited distribution (indoor)
4 – Flame/Smoke Rating D = Dual rated riser (OFNR) and low smoke zero halogen (LSZH) 5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 6.25/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 02 = 2-fibre 04 = 4-fibre 06 = 6-fibre 08 = 8-fibre 12 = 12-fibre
8 – Dash9 and 10 – Jacket color BL = Black
Character
Example
1
F
2
P
3
T
4
N
5
5
6
1
7
2
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM4
3 – Cable Construction U = Indoor/outdoor central tube (up to 24 fibres) T = Indoor/outdoor stranded tube (all fibre counts)4 – Flame Rating N = Non-rated
5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 06 = 6-fibre 08 = 8-fibre 12 = 12-fibre 24 = 24-fibre 36 = 36-fibre 48 = 48-fibre 72 = 72-fibre 96 = 96-fibre 1A = 144-fibre
Character
Example
Gel-filled tube containingup to 12 fibre Rip cord
Outer jacket Water-blocking tape
Central strength member
Opti-Core ® Gel-Filled All-Dielectric Outside Plant Cable For use outdoors in aerial or duct applications. Stranded loose tube constructions are all-dielectric. No need to ground or bond.
Strengthmember
Filler tube
13
Fibre Cable for EMEA (Europe, Middle East, and Africa)
1
F
2
P
3
S
4
N
5
5
6
1
7
2
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM4
3 – Cable Construction S = Gel-filled single armor single jacket outside plant cable4 – Flame Rating N = Non-rated
5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 04 = 4-fibre 06 = 6-fibre 08 = 8-fibre 12 = 12-fibre 24 = 24-fibre
Character
Example
Rip cord
Water blocking strength member
Opti-Core ® Gel-Filled Single Armor Single Jacket Outside Plant Cable For use outdoors in direct burial applications. Central loose tube constructions are armored with corrugated steel tape for greater crush resistance.
Flame retardantjacket
Gel-filled tube containing 24 –250µm fibers
Corrugatedsteel armor
1
F
2
P
3
Q
4
N
5
5
6
1
7
2
8
B
1 and 2 – Fibre Product FP = Fibre – OM1, OM2, OS2 FQ = Fibre – OM3, OM43 – Cable Construction Q = Gel-filled single armor double jacket outside plant cable
4 – Flame Rating N = Non rated 5 – Fibre Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fibre Count 02 = 2-fibre 04 = 4-fibre 06 = 6-fibre 08 = 8-fibre 12 = 12-fibre 24 = 24-fibre 36 = 36-fibre
48 = 48-fibre 72 = 72-fibre 96 = 96-fibre 1A = 144-fibre8 – Fibre Cable B = single armor double jacket stranded tube
Character
Example
Gel-filled tube containing up to 12 fibres
Rip cord
Outer jacketCorrugatedsteel armor
Inner jacket
Opti-Core ® Gel-Filled Single Armor Double Jacket Outside Plant CableFor use outdoors in direct burial applications. Stranded loose tube constructions are armored with corrugated steel tape for greater crush resistance.
Filler tube
Strength member
Central strengthmember
Visit www.panduit.com for more information.14
Fiber Cable for APAC(Asia Pacific)
1
F
2
L
3
D
4
L
5
5
6
0
7
6
8
Y
1 and 2 – Fiber Product FL = Fiber – OS2, OM1, OM2, OM3, OM43 – Cable Construction D = Distribution cable4 – Flame/Smoke Rating L = Low smoke zero halogen (LSZH) R = Riser
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber 48 = 48-fiber
8 – RoHS Y = RoHS compliant
Character
Example
Strength members
Optical fiber
Outer jacket
900µm buffer
Opti-Core ® Indoor Distribution CableFor indoor use in intrabuilding backbone and horizontal installations.
Opti-Core ® Interconnect CableUsed in interconnect, horizontal installations, routing in tight spaces such as panels, cable trays, and fiber-to-the-desk (FTTD) applications.
1
F
2
L
3
I
4
L
5
X
6
0
7
2
8
Y
1 and 2 – Fiber Product FL = Fiber – OS2, OM1, OM2, OM3, OM43 – Cable construction I = Interconnect zipcord
4 – Flame/Smoke Rating L = Low smoke zero halogen (LSZH) R = Riser
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 6.25/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber8 –RoHS Y = RoHs compliant
Character
Example
Strength members
Outer jacket
Optical fiber
900µm buffer
15
Fiber Cable for APAC (Asia Pacific)
1
F
2
L
3
K
4
R
5
5
6
1
7
2
1 and 2 – Fiber Product FL = Fiber – OM1, OM2, OS2, OM3, OM43 – Product Type K = Indoor/outdoor tight buffered unarmored
4 – Flame/Smoke Rating R = Riser (ONFR) L = Low Smoke Zero halogen (LSZH)
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber 16 = 16-fiber 24 = 24-fiber 48 = 48-fiber 72 = 72-fiber
Character
Example
Strength members
Outer jacket
Optical fiber
Opti-Core ® Indoor/Outdoor All-Dielectric Cable with Tight Buffered FibersFor use indoor and outdoors.
900µm Buffer
Water-blocking gelCentral loose tube
Outer jacket
Rip cord
250µm coated optical fiber
Opti-Core ® Indoor/Outdoor All-Dielectric CableFor use indoor or outdoors. Central loose tube and stranded loose tube constructions are all-dielectric.
1
F
2
L
3
C
4
L
5
5
6
0
7
2
8
Y
Character
Example
1 and 2 – Fiber Product FL = Fiber – OM1, OM2, OS2, OM3, OM43 – Product Type C = Indoor/outdoor central tube (up to 12 fibers) N = Indoor/outdoor stranded tube (24 fibers and greater)
4 – Flame/Smoke Rating R = Riser (OFNR) L = Low smoke zero halogen (LSZH)
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 08 = 8-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber 48 = 48-fiber
Water-blocking glass yarn
Visit www.panduit.com for more information.16
1
F
2
L
3
T
4
N
5
5
6
1
7
2
1 and 2 – Fiber FL = Fiber – OS2, OM1, OM2, OM3, OM43 – Cable Construction T = Outside plant stranded cable (all fiber counts)4 – Flame/Smoke Rating N = Non-rated
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber
48 = 48-fiber 72 = 72-fiber 96 = 96-fiber 1A = 144-fiber
Character
Example
Opti-Core ® Gel-Filled All-Dielectric Outside Plant CableFor use outdoors in aerial or duct applications. Stranded constructions are all-dielectric. Gel-filled. Non-rated PE outer jacket.
Fiber Cable for APAC(Asia Pacific)
Tube containingup to 12 fibers Rip cord
Filler tubes
Central strengthmember
Outer strengthmember
Outer jacket
1
F
2
S
3
A
4
D
5
5
6
1
7
2
8
–
9
B
10
L
1 and 2 – Fiber Product FS= OM1, OM2, OS2 FO= OM3, OM43 – Cable Construction A = Dielectric conduited distribution (indoor)
4 – Flame/Smoke Rating D = Dual rated riser (OFNR) and low smoke zero halogen (LSZH) 5 – Fiber Type 9 = OS2 9/125 µm 6 = OM1 6.25/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber
8 – Dash9 and 10 – Jacket color BL = Black
Character
Example
Cable outer jacket
Aramid strength members
Optical fiber
900µm Buffer
Dielectricconduit
Opti-Core ® Dielectric Conduited (DCF) Fiber Optic CableFor indoor use in intrabuilding backbone and horizontal installations.
17
1
F
2
L
3
W
4
N
5
5
6
1
7
2
1 and 2 – Fiber Product FL = Fiber – OS2, OM1, OM2, OM3, OM43 – Cable Construction W = Outside plant armored stranded cable (all fiber counts)4 – Flame/Smoke Rating N = Non-rated
5 – Fiber Type 9 = OS2 9/125µm 6 = OM1 62.5/125µm 5 = OM2 50/125µm X = OM3 10G 50/125µm Z = OM4 10G 50/125µm
6 and 7 – Fiber Count 02 = 2-fiber 04 = 4-fiber 06 = 6-fiber 08 = 8-fiber 12 = 12-fiber 24 = 24-fiber 36 = 36-fiber
48 = 48-fiber 72 = 72-fiber 96 = 96-fiber 1A = 144-fiber
Character
Example
Gel-filled tube containingup to 12 fibers
Rip cord
Optical fiber
Filler tube
Central strengthmember
Opti-Core ® Gel-Filled Armored Outside Plant CableFor use outdoors in direct burial applications. Stranded loose tube constructions are armored with corrugated steel tape for greater crush resistance. Gel-filled. Non-rated PE outer jacket.
Outer strengthmember
Water-blocking tape
Corrugated steel armor
Fiber Cable for APAC (Asia Pacific)
Visit www.panduit.com for more information.18
Pre-Polished Fiber Optic Kit & Connectors
OptiCam® Pre-Polished Cam Fiber Optic Termination Kit• For termination of all Panduit OptiCam® Pre-Polished and Field Polish Connectors
• OptiCam® Termination Tool simplifies tooling and termination, and virtually eliminates operator error by providing
visual indication of proper termination after the cam step has been completed
• No adhesive or electricity required for pre-polished termination
• Include installation instructions and stripping templates for all Panduit® OptiCam® Pre-Polished Connectors;
also available on www.panduit.com
Field Polish Fiber Optic Termination Kit• Fast acting adhesive; no long curing epoxy required for field polish termination
• FIELDKIT provides consumable for terminating up to 200 field polish connectors
• Include installation instructions and stripping templates for all Panduit Field Polish Connectors;
also available on www.panduit.com
OptiCam® Pre-Polished Cam Fiber Optic Termination Kit• For termination of all Panduit OptiCam® Pre-Polished and Field Polish Connectors
• OptiCam® Termination Tool simplifies tooling and termination, and virtually eliminates operator error by providing
visual indication of proper termination after the cam step has been completed
• No adhesive or electricity required for pre-polished termination
• Include installation instructions and stripping templates for all Panduit® OptiCam® Pre-Polished Connectors;
also available on www.panduit.com
OptiCam® Pre-Polished and Field Polish Fiber Optic Connectors• TIA/EIA-604 FOCIS compatible connectors
• Exceed TIA/EIA-568-B.3 requirements
• Connector housing and boot colors follow TIA/EIA-568-C.3 suggested color identification scheme
• Non-optical disconnect maintains data transmission under tensile loads for jacketed cable
• Quick installation; provide field termination in less than half the time of field polish connectors
• Patented re-termination capability provides yield rates approaching 100%
• Factory pre-polished fiber endface eliminates time-consuming field polishing to reduce installation costs, labor, scrap
and the number of tools required
• Cam activated fiber and buffer clamp mechanisms provide superior fiber and buffer retention – less sensitivity to fiber
tensile loading
FCAMKIT for use with Pre-Polished Fiber Optic Connectors
FIELDKIT for use with Field Polished Fiber Optic Connectors
19
Pre-Polished Fiber Optic Kit & Connectors
LC OptiCam® Pre-Polished Fiber Optic Connectors
SC OptiCam® Pre-Polished Fiber Optic Connectors
Quick installation - provides field termination in less than half the time of field polish connectors. Patented re-termination capability.
*All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
s e l e c t i o n i n f o r m a t i o n
s e l e c t i o n i n f o r m a t i o n
Part NumberConnector
TypeFerruleMaterial
FiberFerrule Finish
BackboneColor
BootColor
AverageInsertion Loss**
ReturnLoss
FLCSMCXAQY Simplex ZirconiaCeramic
10 GbE 50/125μm (laser optimized) OM3/OM4
SPC Aqua Aqua 0.3dB >26dBFLCDMCXAQY Duplex
FLCSMC5BLY Simplex ZirconiaCeramic
50/125μm OM2 SPC Black Black 0.3dB >20dBFLCDMC5BLY Duplex
FLCSMC6BLY Simplex ZirconiaCeramic
62.5/125μm OM1 SPCElectric
IvoryBlack 0.3dB >20dB
FLCDMC6BLY Duplex
FLCSSCBUY Simplex ZirconiaCeramic 9/125μm OS1/OS2 UPC Blue Blue 0.3dB >50dB
FLCDSCBUY Duplex
Part NumberConnector
TypeFerruleMaterial
FiberFerrule Finish
Housing Color
BackboneColor
BootColor
AverageInsertion Loss**
ReturnLoss
FSCMCXAQ Simplex ZirconiaCeramic
10 GbE 50/125μm (laser optimized) OM3/OM4
SPC Black Aqua Aqua 0.3dB >26dBFSCDMCXAQ Duplex
FSCMC5BL Simplex ZirconiaCeramic 50/125μm OM2 SPC Black Black Black 0.3dB >20dBFSCDMC5BL Duplex
FSCMPC5BL Simplex Composite
FSCMC6BL Simplex ZirconiaCeramic 62.5/125μm OM1 SPC
ElectricIvory
ElectricIvory
Black 0.3dB >20dBFSCDMC6BL Duplex
FSCMPC6BL Simplex Composite
FSCSCBU SimplexZirconiaCeramic 9/125μm OS1/OS2 UPC Blue Blue Blue 0.3dB >50dB
**All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
Opti-Cam® Pre-Polished Fiber Optic Connectors
Visit www.panduit.com for more information.20
Field Polished Fiber Optic Kit & Connectors
LC OptiCam® Field Polish Fiber Optic ConnectorsNon-optical disconnect maintains data transmission under tensile loads for jacketed cable. Tight buffered fiber cable type recommended.
s e l e c t i o n i n f o r m a t i o nPart Number
Connector Type
Cable Type Fiber FerruleHousing
ColorBoot Color
Average Insertion Loss*
Return Loss
FLCSMEIY Simplex900μm buffered fiber and
1.6mm – 2.0mm jacketed cable
OM1Multimode
Zirconia Ceramic
Electric Ivory
Electric Ivory
0.1dB >20FLCSM3.0EI Simplex 3.0mm jacketed cable
FLCDMEIY Duplex 1.6mm – 2.0mm jacketed cable
FLCDM900EIY Duplex 900μm buffered fiber
FLCDM3.0EI Duplex 3.0mm jacketed cable
FLCSMBLY Simplex900μm buffered fiber and
1.6mm – 2.0mm jacketed cable
OM2, OM3, OM4 Multimode
Zirconia Ceramic
Black Black 0.1dB >20FLCSM3.0BL Simplex 3.0mm jacketed cable
FLCDMBLY Duplex 1.6mm – 2.0mm jacketed cable
FLCDM900BLY Duplex 900μm buffered fiber
FLCDM3.0BL Duplex 3.0mm jacketed cable
*All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
ST OptiCam® Pre-Polished Fiber Optic Connectors
**All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
s e l e c t i o n i n f o r m a t i o n
Part NumberConnector
TypeFerruleMaterial
FiberFerrule Finish
BackboneColor
BootColor
AverageInsertion Loss**
ReturnLoss
FSTMCXAQ SimplexZirconiaCeramic
10 GbE 50/125μm (laseroptimized) OM3/OM4
SPC
Aqua Aqua 0.3dB >26dB
FSTMC5BL SimplexZirconiaCeramic
50/125μm OM2 Black Black 0.3dB >20dB
FSTMC6BL SimplexZirconiaCeramic
62.5/125μm OM1 Black Black 0.3dB >20dB
FSTSCBU SimplexZirconiaCeramic
9/125μm OS1/OS2 UPC Blue Blue 0.3dB >50dB
Field Polish Fiber Optic Connectors
21
Field Polished Fiber Optic Kit & Connectors
ST OptiCam® Field Polish Fiber Optic Connectors
SC OptiCam® Field Polish Fiber Optic Connectors
s e l e c t i o n i n f o r m a t i o n
Part NumberConnector
TypeFerrule Material
FiberFerrule Finish
Housing Color
Backbone Color
Boot Color
Average Insertion Loss*
Return Loss
FSTMABL SimplexZirconia Ceramic
Multimode UPC BlackNickel
Plated ZincBlack 0.15dB (multimode) >20dB (multimode)
FSTMARD SimplexZirconia Ceramic
Multimode UPC RedNickel
Plated ZincRed 0.15dB (multimode) >20dB (multimode)
FSTSABU SimplexZirconia Ceramic
Singlemode UPC BlueNickel
Plated ZincBlue
0.20dB (single-mode)
>40dB (singlemode)
*All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
Part NumberConnector
TypeCable Type Fiber Ferrule
Housing Color
Boot ColorAverage
Insertion Loss*Return Loss
FSCM5BL Simplex900μm buffered fiber and
3.0mm jacketed cable
MultimodeZirconiaCeramic
BlackBlack
0.1dB >20
FSCM2.05BL Simplex900 micron buffered fiber and1.6 – 2.0mm jacketed cable
FSCDM5BL Duplex 3.0mm jacketed cable
FSCMBL Simplex900μm buffered fiber and
3.0mm jacketed cable
ElectricIvory
FSCMRD Simplex900μm buffered fiber and
3.0mm jacketed cable Red
FSCM2.0BL Simplex900μm buffered fiber and
1.6mm – 2.0mm jacketed cable Black
FSCM2.0RD Simplex900μm buffered fiber and
1.6mm – 2.0mm jacketed cable Red
FSCDM Duplex 3.0mm jacketed cable Red and Black
FSCSBU Simplex900μm buffered fiber and
3.0mm jacketed cableSinglemode
ZirconiaCeramic
Blue Blue 0.15dB >40FSCS2.0BU Simplex
900μm buffered fiber and1.6mm – 2.0mm jacketed cable
*All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171.
Visit www.panduit.com for more information.22
1 Blue 13 Blue with black tracer
2 Orange 14 Orange with black tracer
3 Green 15 Green with black tracer
4 Brown 16 Brown with black tracer
5 Slate 17 Slate with black tracer
6 White 18 White with black tracer
7 Red 19 Red with black tracer
8 Black 20 Black with black tracer
9 Yellow 21 Yellow with black tracer
10 Violet 22 Violet with black tracer
11 Rose 23 Rose with black tracer
12 Aqua 24 Aqua with black tracer
Contact Customer Service for fiber cable minimum order quantities, lead times, and stocked availability.
TIA-598-C Fiber Color Code Chart
TIA 598-CThe Telecommunications Industry Association's TIA-598-C Optical Fiber Cable Color Coding, is an American National
Standard, that provides all necessary information for color-coding optical fiber cables in a uniform manner. It defines
identification schemes for fibers, buffered fibers, fiber units, and groups of fiber units within outside plant and premises optical
fiber cables. This standard allows for fiber units to be identified by means of a printed legend. The legend will contain a
corresponding printed numerical position number and/or color for use in identification.
Optical Fiber Color Coding
©2016 Panduit Corp. ALL RIGHTS RESERVED. Printed in the U.S.A. FBLC01--SA-ENG 9/2016
Panduit Corp.World Headquarters
Tinley Park, IL 60487
[email protected] and Canada: 800.777.3300
Europe, Middle East, and Africa: 44.20.8601.7200
Latin America: 52.33.3777.6000Asia Pacific: 65.6305.7575
www.panduit.com