Upload
vokien
View
223
Download
0
Embed Size (px)
Citation preview
Beld
enData CablesEuropean Edition
Belden Data CablesBelden Data Cables
1
Reliability, performance
Over the years, Belden has become an international byword for premium quality andreliability, an accolade for excellence earnedthrough decades of dedication to meetingthe highest industry standards. Our strategicobjective is to provide our customers withsuperior solutions for their present and futurewire and cable needs. Accordingly, every solution we devise is based on performance,innovation and reliability – the three corner-stones of Belden’s business strategy.
Reliable Performance through Innovation
A long history of innovationFor the past 100 years, Belden has been anacknowledged front-runner in the wire andcable industry, developing novel technolo-gies and processes for the manufacture ofinnovative wire and cable products. Productsthat keep our customers at the forefront ofnew developments in their chosen field.
Starting in 1902, when the company was founded in Chicago, Belden has consistentlypioneered breakthrough technologies andset new industry standards. This trend wasset with early successes like Beldenamel insulation (1905) and the introduction of thesoft rubber plug in 1927. Ever since, Beldenhas been an industry innovator, conceivingand developing special applications in ca-bling, shielding and jacketing. All focused on customer needs. All clearly establishingBelden’s leadership in wire and cable tech-nology.
Belden’s commitment to innovation has historically fuelled new growth for industryplayers. It has also earned Belden global innovation leadership that is constantly driven by the Belden Engineering Centres.For instance with Duobond®, Flamarrest®,
French Braid™, MediaTwist® and DataTwist®
600e. Another yardstick for measuring thesuccess of our novel products are the manypatents we hold. But the ultimate criterion isthe fitness for use of the products we supplyto our customers.
Global playerThe company’s successful growth strategy inthe 1990s led 1999 to the purchase of CableSystems International, the largest specialtytelecom cable facility in the world. Othercapabilities were created by acquisitions inAustria, Australia, Germany, Hungary, the USAand the Netherlands, where Belden has itsEuropean headquarters and a large R&D Centreand manufacturing facility. Apart from Europeand the US, Belden’s world-wide presence in-cludes marketing and sales organizations inAsia Pacific, Latin America and the Middle East.
Today, Belden is a global player in the wireand cable industry, designing, manufacturingand marketing specialty cable, such as copper,and optical fibre cable for electrical, electronicand communications equipment. Reliableproducts that help Belden’s customers keeppace with the shifting dynamics of thesefast-moving markets.
Table of ContentsReliable Performance through Innovation
Belden Quality
Cable Finder
Unshielded cablesUTP Category 5E
UTP Category 6
Shielded cables(S)FTP Category 5E
(S)FTP Category 6
ISTP Category 7
Ordering Information & DataTwist® Colour Code Table
1 – 2
3 – 4
5
6 – 7
8 – 10
11 – 12
13
14
14
Page
2
CHESTER,CHESHIRE
LYON
VENLO
MADRID
NYNÄSHAMN
VILLINGEN-SCHWENNINGEN
MOSCOW
MILANO
PRODUCTION
SALES OFFICES
The Netherlands
European manufacturing operationsAs Belden’s global business plans call for a commitment to local markets world-wide and a thorough understanding of local dynamics, Belden has establisheda very significant presence in core European markets. This ensures that appropriate solutions can always be found to meet the cable and wire needs of our European customers.
Belden has the largest range of cable products in all the marketswe serve. Dedicated products matched to local needs. These include over 10.000 products for computer networking and computer equipment; for telecommunications and industrial instrumentation and control; for broadcasting and entertainment;and for cable television and electrical equipment.
With European sales accounting for almost a quarter of Belden’s world-wide turnover, Belden has clearly demonstrated the successof its ‘Think global, act local’ approach. And with its 1000-strong workforce across Europe – and sales offices from Moscow to Madrid and from Stockholm to Dubai – Belden has a strong local capability to understand customers’ problems and to provide the answer.
Belden’s European headquarters and manufacturing base is in the Netherlands, where the company also has its European Engineering Centre.
● Digital telephony cables● Shielded and non-shielded cables● Multi-conductor cables● Optical fibre cables● Audio/video cables● Coaxial broadband cables● Electrical cables
To request detailed brochures and data-sheets on our product lines and the extensiveBelden Master Catalog, please contact your local Belden representative or send an e-mail to [email protected]
Addressing environmental issues correctly is recognized as a high priority, particularly in the industrialized world and not least atBelden. Accordingly, the company makesevery effort to minimize the environmentalimpact of its operations and products.
Recognizing ecological concerns shared by customers and consumers world-wide,from 1999-2001 a working group at Belden’sEuropean headquarters in Venlo completed
comprehensive preparations for ISO 14001EMS certification. This environmental man-agement and audit system was implementedand certified in 2001. The progress achievedin the practical implementation of Belden’senvironmental objectives will be publishedeach year. This will include the measurestaken by the company to minimize the envi-ronmental impact of Belden’s operations,also in respect of (energy) savings in produc-tion and novel materials and processes.
Detailed brochuresFull-colour brochures are available on theextensive range of Belden products:
ISO 14001 EMS – Environmental Management System
USA Germany
BUDAPEST
Reliable Performance through Innovation
Belden Data CablesBelden Data Cables
Monitoring & maintaining quality Before releasing any new products for production, all critical charac-teristics, such as dimensions, electricals, and physicals are targetedto meet a capability index (Cpk) ≥ 1.33, which corresponds to a99.997% passing rate. A Cpk is an index that quantifies the capabilityof a product’s design and manufacturing process. It takes the actualperformance of a product and compares it to a benchmark level ofperformance (e.g.: the industry standard).
The Cpk values are determined through capability studies, whichrepresent the final product design and manufacturing set-ups. Thisincludes statistically valid run times, sampling quantities and methods.The result is a Cpk value that corresponds to a predicted defect ratefor the product.
Based on these statistics (measuring 100% is simply not possible)99.997% of the Belden products will pass the applicable cable standards. If Belden specifies headroom above a cable standard this will always means in addition to the Cpk = 1.33 range (4�).
Variation of a product characteristics that performs just within our specification.
Belden’s Cpk testing methods are actually more reliable than simple“pass/ fail” testing on cable as it comes off the manufacturing line.Rather than merely testing batches of cable, Cpk testing allowsBelden to monitor and control the long-term quality and performanceof the cable we produce. Cpk’s are tracked constantly through PlantQuality Assurance, using in-house developed Quality Data AcquisitionSystems. The generated Cpk values give us an accurate measurementof quality over time, and are used to drive continuous quality improve-ments.It enables us to adjust our manufacturing processes in ways that ensurethe production of high performance cable, day in day out.
3
Belden Quality
The Belden approach to cable quality
Belden’s commitment to quality begins even before its products leavethe product development phase. Not only does Belden design productsto achieve a given level of performance, it also ensures that theseproducts can be manufactured in a way that makes that performancepossible and consistent.
The keyword in the Belden approach is prevention. Prevention involvesthe use of key parameters of product performance and statistical methods to monitor the process and identify changes that affect the quality of the product and adjust the process accordingly. The responsibility for quality moves from the inspectors to the design and manufacturing departments.
Product quality at Belden begins long before we ever manufacture a single meter of cable. Here’s a look at how we do it:
Design for manufacturabilityDelivering a superior product means being sure you make a superiorproduct, day after day. Design for Manufacturability (DFM) seeks toidentify and account for the challenges inherent in any manufacturingprocess and address them up front. It takes into account every aspectof manufacturing: materials, machines, operations, environmental factors, and more.
The purpose of DFM is to design products that are robust enoughto stand up to the challenges of manufacturing to yield consistent,superior product quality. DFM is focused on the entire manufacturingprocess and how it can be monitored, controlled, and adjusted toachieve our quality goals.
The benefit to Belden customers is that our products achieve highperformance standards that are both consistent and measurable.
Test lab Belden Engineering
Centre
Headroom (average worst case margin from spec.)
3 x Standard deviationCpk =
99.7% of Product
Avg: 4.0 dB
7.0 dB1.0 dB
Lower Spec.
99.997% of Product
3� = 1.0 Cpk
� = 1.0
3� = 1.33 Cpk = Design Goal
+3� +4�
–10 – 5 0 5 10 15 20
– 3�– 4�
Bonded pairsInstalled performance is the performance of a channel in real worldinstallation conditions. Common real world conditions include the useof cable that have experienced severe flexing when pulled aroundbends and corners and cable coiled into service loops and/or stuffedinto outlet boxes. The Belden Bonded Pair cables provide betterinstallable performance™, due to its unique, patented design.
Better by design
For a twisted pair cable, a solid design begins with the individual con-ductors and their relationship to one another forming a pair.An ideal pair is comprised of two perfectly balanced insulated conductorsthat are mirror images of each other. The copper used in the two con-ductors is identical – with exactly the same dimensions – and is alsoperfectly centered, or concentric, within each insulated conductor.
The ideal twisted pair, with perfect centricity and concentricity.
To maintain this perfect balance, the center-to-center distance, orcentricity, between the copper conductors must remain fixed andshould never vary – not even in the slightest! In balanced signal trans-mission on an ideal pair, these concentricity and centricity factors helpensure that the signal does not radiate or bleed off the pair and thatthe pair cancels out all incoming noise.When the conductors of a twisted pair become separated, impedancemismatches, Return Loss (RL), and crosstalk problems arise. In orderto prevent this separation from occurring and to provide structuralstability, Belden has developed its patented Bonded Pair technology.As the picture illustrates, even when a Bonded Pair cable is bent, itsconductor-to-conductor spacing remains stable.
Only a Bonded Pair will not gap when the pair is bent around a corner.
4
Belden Quality
Design dictates performance
Belden Bonded Pair cables are designed to maintain their outstandingperformance after installation. To demonstrate this, an InstallationStress Test has been designed and implemented. To simulate pullingthe cable through and around cable trays, ceilings and walls, eachcable was run through a series of controlled bends and twists.Next, the end of the cable was placed into an outlet box, and a 3 meterlength of the cable was loosely coiled into a service loop at the workstations end. The cables were tested before and after the test to identify any changes in performance.
If we compare the RL values of the Cat5E Belden Bonded Pair cablevs. an industry leading Cat5E cable we find that the Unbonded Paircable’s RL value degraded by more than 12 dB, or more than 15 timestheir before-installation values.
Belden’s Bonded Pair cables exhibited little change in RL perform-ance. (For more detailed information, please refer to Belden TechnicalBulletin TB-66, The Impact of Typical Installation Stresses on cablePerformance.)
Performance reduces costs
To further document the after-installation performance of both BondedPair and Unbonded Pair cables, Belden surveyed a large number ofcontractors regarding their installation experiences.This survey showed a clear difference between the two cable typesafter installation was complete and field testing was conducted to verify compliance with industry standards, both proposed Category 6and Category 5E. It showed that the Belden Bonded Pair cables causesignificantly less test failures compared to Unbonded Pair cables.In fact, with Bonded Pair cables time savings of up to 1.5 minutes per drop (Cat 5E) and 2.5 minutes per drop (Cat 6) can be expectedbecause far less troubleshooting and re-work is required.(For more detailed information, please refer to Belden Technical Bulletin TB-67, Contractor Field-Testing Survey Reveals Performance-Related Cost savings Using Bonded Pair Cables.)
Industry 350 MHz Cat 5e Cable Return Loss Margins(20 – 100 MHz)
Belden DataTwist 350 Cat 5e Return Loss Margins(20 – 100 MHz)
Data Pairs Blue Orange Green Brown
Hig
her
is b
ette
r
Mar
gin
(d
B)
Mar
gin
(d
B)
Installed
Initial Installed
Initial
Fai
lH
igh
er is
bet
ter
Spec.Limit
Spec.Limit
Centricity
Centricity
Unbonded Pair Bonded Pair
Shielded Cables
(S)FTP Category 5E
ISTP Category 7
(S)FTP Category 6
UTP Category 6
UTP Category 5E
Belden Data CablesBelden Data Cables
5
Cable Finder
1583E1583ENH1667E1667ENH1700E1700ENH1702E1702ENH1592A1592ANH1752A1752ANH
7965E7965ENH7812E7812ENH1872A1872ANH1875GB1875GBNH7851A7851ANH
1633E1633ENH1668E1668ENH1730A1730ANH1633E+1633ENH+1668E+1668ENH+1868E1868ENH
7860E7860ENH7860E+7860ENH+
1885ENH1887ENH
Belden partnumber
XXXX
XXXXXX
XX
USproduct
● All specification limits according to FCD ISO/IEC 11801 2nd. Edition (October 2001), unless otherwise stated. Attenuation values at frequencies below 4 MHz in this brochure are for reference only, in accordance with ISO/ IEC 11801.
● Typical values represent values from multiple tests of our products. These numbers are not guaranteed but are designed to give the user an idea of the products typical capabilities. The minimum/maximum values are guaranteed values.
● For ordering information see page 14.
XXXXXXXX
XXXX
XXXX
XXXXXX
XXXX
XX
Europeproduct
Twin 1583ETwin 1583ENHDataTwist® 350DataTwist® 350
Twin 1700ETwin 1700ENH
DataTwist® PatchDataTwist® Patch
DataTwist® 350 PatchDataTwist® 350 Patch
MediaTwist®
MediaTwist®
MediaTwist® PatchMediaTwist® PatchDataTwist® 600eDataTwist® 600e
Twin 1633ETwin 1633ENH
Braided 1633EBraided 1633ENH
Twin 1633E+Twin 1633ENH+
PatchPatch
Braided 7860EBraided 7860ENH
Twin 1885ENH
Description
100100100100350350350350350350350350
250250250250350350350350600600
100100100100100100100100100100100100
250250250250
600600
Tested tofrequency
(MHz)
NH jacket
NH jacketbonded pairs
bonded pairs, NH jacketbonded pairs
bonded pairs, NH jacket
NH jacketbonded pairs
bonded pairs, NH jacket
NH jacketbonded pairs
bonded pairs, NH jacketbonded pairs
bonded pairs, NH jacketbonded pairs
bonded pairs, NH jacketbonded pairs
bonded pairs, NH jacket
NH jacket
NH jacketbonded pairs
bonded pairs, NH jacket
NH jacket
NH jacket
NH jacket
bonded pairsbonded pairs, NH jacket
bonded pairsbonded pairs, NH jacket
NH jacketNH jacket
Remarks
XXXXXXXX
XXXX
XXXX
XXXXXX
XXXX
XX
EN50173
2nd ed.
XXXXXXXXXXXX
XXXXXXXXXX
XXXX
XXXXXX
XXXX
TIA/EIA568-B2
XXXXXXXXXXXX
XXXXXXXX
XXXXXXXXXXXX
XXXX
XX
ISO/IEC11801
2nd ed.
666666667777
88889999
1010
111111111111121212121212
13131313
1414
Page
Origin Industry standards
Notes:● Plenum versions and various multipair cables
available upon request.● Please check for available outdoor cables.
Unshielded Cables
UTP Category 5E
6
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 94Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 0.90
Nominal overall diameter (mm): 5.0Impedance (Ohm): 100 Ohm ± 15 %Energy of flame (kJ/m):
Single TwinE 305 610ENH 298 596
Belden 1583ENH Halogen-free version
Belden 1667E Twin version of 1583E
Belden 1667ENH Twin version of 1583ENH
Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 24. Solid bare copper conductors, polyolefine insulation. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 5E)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.9607357716171
56.071
53.069
20.031
4.03.9566453624959
52.361
49.358
23.033
5.75.6525949574353
46.154
43.151
24.541
6.36.2505847564151
44.052
41.050
25.042
8.07.9475544533746
39.248
36.245
25.041
9.08.9465443523543
36.845
33.843
25.041
10.19.9445341513342
34.242
31.241
24.339
11.411.2435140493139
31.540
28.538
23.636
16.516.0384735452533
21.831
18.829
21.534
21.319.8354432422128
14.024
11.022
20.132
1 4 8 10 16 20 25 31.25 62.5 100
Standard lengths (put-ups): Standard weight:U 1000 ft. U 305 m 8.5 kg
1000 ft. 305 m 8.5 kg1640 ft. 500 m 14.0 kg3280 ft. 1000 m 28.0 kg
Belden 1583E Cat. 5E
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 94Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 0.95
Nominal overall diameter (mm): 5.0Impedance (Ohm): 100 Ohm ± 15 %Energy of flame (kJ/m):
Single TwinE 305 610ENH 298 596
Belden 1700ENH Halogen-free version
Belden 1702E Twin version of 1700E
Belden 1702ENH Twin version of 1700ENH
Product description
Unshielded Twisted Pair Cable, 4 bonded pairs x AWG 24, ripcord. Solid bare copper conductors, polyolefine insulation. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 5E)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.9607357716171
56.071
53.069
20.031
4.03.9566453624959
52.360
49.358
23.033
6.36.2505847564151
44.052
41.050
25.040
8.07.9475544533746
39.247
36.245
25.042
9.08.9465443523543
36.845
33.843
25.042
11.411.2435140493139
31.540
28.538
23.642
16.516.0384735452533
21.831
18.829
21.541
21.319.8354432422128
14.024
11.022
20.141
–25.0
–40–
38–
25–
15–
13–
37
–28.5
–38–
36–
23–
10–8–
37
1 4 10 16 20 31.25 62.5 100 155 200–
35.9–
36–
34–
19–––––
35
310–
38.5–
35–
33–
18–––––
34
350
Standard lengths (put-ups): Standard weight:U 1000 ft. U 305 m 8.5 kg
1000 ft. 305 m 8.5 kg1640 ft. 500 m 14.0 kg3280 ft. 1000 m 28.0 kg
Belden 1700E DataTwist ® 350 Bonded pairs Cat. 5E
Belden Data CablesBelden Data Cables
7
UTP Category 5E
Frequency (MHz)Attenuation (dB/100 m)
PS-NEXT (dB)
PS-ELFEXT (dB)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, Blue, Red, Green, Yellow, Orange, Violet, White, BlackVelocity of propagation (%): 69Typ. DCR (Ohm/100 m): 7.9Nominal capacitance (pF/ ft.): 15Diameter of insulated conductor (mm): 0.99
Nominal overall diameter (mm): 8.0Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 25 %
Belden 1592ANH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 24. Stranded bare copper conductors, polyolefine insulated singles, PVC jacket. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: TIA/EIA 568-B2 , ISO/ IEC 11801
Flame test: UL CM UL 1581 Vertical Tray, CSA FT1
guaranteed max.typical
guaranteed min.typical
guaranteed min.typical
guaranteed min.typical
guaranteed min.typical
2.51.962.373
60.869
59.871
20.025
1
Standard lengths (put-ups): Standard weight:U 1000 ft. U 305 m 9.5 kg
1000 ft. 305 m 9.5 kg
Belden 1592A DataTwist® Patch Cat. 5E
4.94.153.363
48.751
48.459
23.028
47.86.647.357
40.848
39.550
25.033
109.98.444.354
36.746
34.446
25.033
1611.19.342.853
34.743
31.744
25.033
2012.510.541.351
32.841
28.841
24.332
2514.111.839.950
30.939
25.838
23.631
31.2520.416.735.445
24.833
15.028
21.529
62.526.421.432.342
20.8295.921
20.128
10033.726.929.540
16.925––
15.827
15538.931.727.839
15.023–8
15.026
200–
36.7–
31–––––
24
25045.338.5
–29–––––
22
350
Frequency (MHz)Attenuation (dB/100 m)
PS-NEXT (dB)
PS-ELFEXT (dB)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, Blue, Red, Green, Yellow, Orange, Violet, White, BlackVelocity of propagation (%): 70Typ. DCR (Ohm/100 m): 8.6Nominal capacitance (pF/ ft.): 15Diameter of insulated conductor (mm): 0.99
Nominal overall diameter (mm): 8.0Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 25 %
guaranteed max.typical
guaranteed min.typical
guaranteed min.typical
guaranteed min.typical
guaranteed min.typical
2.41.965.376
69.873
62.972
20.029
1
Standard lengths (put-ups): Standard weight:U 1000 ft. U 305 m 11.3 kg
1000 ft. 305 m 11.3 kg
4.83.956.372
48.771
51.566
23.031
47.76.250.363
40.863
42.655
25.034
109.87.947.361
36.748
37.551
25.034
1611.09.045.860
34.745
34.849
25.035
2012.410.245.357
32.843
32.045
24.335
2513.911.042.955
30.941
29.042
23.635
31.2520.115.938.453
24.835
18.235
21.535
62.526.120.735.350
20.8319.327
20.133
10033.326.232.547
16.928–
1920.033
15538.430.830.845
15.025–
1219.031
20043.735.829.343–––7
18.0*30*
25053.245.327.242––––
17.030
350
Belden 1752ANH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 24. Stranded tinned copper conductors, polyolefine insulated singles with bonded pairs, PVC jacket. Colour code: see DataTwist® colour code table onpage 14.
Applicable industry standards: TIA/EIA 568-B2 , ISO/ IEC 11801
Flame test: UL CM UL 1581 Vertical Tray, CSA FT1
Belden 1752A DataTwist ® 350 Bonded pairs Patch Cat. 5E
* values at 310 MHz
8
UTP Category 6
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 70Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 1.01
Nominal overall diameter (mm): 6.2Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 22 %Energy of flame (kJ/m):
SingleE 490ENH 478
Belden 7965ENH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 23. Solid bare copper conductors, polyolefine insulation, spline. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 6)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.7697667746570
65.074
63.072
20.033
4.03.5657363715364
61.370
59.368
23.036
6.05.6596657644557
53.360
51.358
25.044
7.67.1566454624151
48.657
46.655
25.042
8.58.0556353613949
46.355
44.353
25.040
9.69.0536151593747
43.852
41.850
24.337
10.710.1525650543545
41.146
39.144
23.638
15.514.4475545532939
31.941
29.939
21.536
19.918.6445242502535
24.433
22.431
20.131
25.323.6414939472131
16.125
14.123
18.827
1 4 10 16 20 25 31.25 62.5 100 15529.127.0404838461929
10.6218.619
18.025
20033.030.73845364317275.3143.312
17.324
250
Standard lengths (put-ups): Standard weight:1640 ft. 500 m 21.5 kg3280 ft. 1000 m 43.0 kg
Belden 7965E Cat. 6
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 70Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 1.05
Nominal overall diameter (mm): 6.5Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 22 %Energy of flame (kJ/m):
SingleE 555ENH 535
Belden 7812ENH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 bonded pairs x AWG 23. Solid bare copper conductors, polyolefine insulation, spline. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 6)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.8698067786570
65.078
63.076
20.034
4.03.5657663745364
61.373
59.371
23.034
6.05.7597057684557
53.364
51.362
25.041
7.67.3566754654151
48.660
46.658
25.042
8.58.2556653643949
46.358
44.356
25.044
9.69.3536451623747
43.855
41.853
24.345
10.710.4526350613545
41.153
39.151
23.646
15.515.1475845562939
31.943
29.941
21.545
19.918.1445542532535
24.437
22.435
20.143
25.323.6415139492131
16.127
14.125
18.840
1 4 10 16 20 25 31.25 62.5 100 15529.127.5404938471929
10.6228.620
18.040
20033.030.83845364317275.3143.312
17.336
250
Standard lengths (put-ups): Standard weight:U 1000 ft. U 305 m 13.1 kg
1640 ft. 500 m 21.5 kg3280 ft. 1000 m 43.0 kg
Belden 7812E Bonded pairs Cat. 6
Belden Data CablesBelden Data Cables
9
UTP Category 6
Frequency (MHz)Attenuation (dB/100 m)
PS-NEXT (dB)
PS-ELFEXT (dB)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, Gold, Brown, Blue, Red,Green, Yellow, Orange, VioletVelocity of propagation (%): 70Typ. DCR (Ohm/100 m): 7.4Nominal capacitance (pF/ ft.): 15Diameter of insulated conductor (mm): 0.96
Nominal overall diameter (mm): 8.0Impedance (Ohm): 1 – 20 MHz: 100 ± 12 %
20 – 200 MHz: 100 ± 15 %200 – 310 MHz: 100 ± 20 %310 – 350 MHz: 100 ± 22 %
max. (TIA /EIA Cat. 6)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
2.01.772.386
64.882
70.384
20.029
1
Standard lengths (put-ups): Standard weight:328 ft. 100 m 4.3 kg
A 1000 ft. A 305 m 13.2 kg
3.83.463.376
52.872
59.573
23.031
46.05.557.370
44.866
51.365
25.034
107.67.054.269
40.762
46.762
25.034
168.57.952.868
38.860
44.360
25.035
209.58.851.366
36.857
41.859
24.335
2510.710.049.965
34.955
39.255
23.635
31.2515.414.145.460
28.950
30.046
21.533
62.519.818.542.354
24.845
22.535
21.033
10025.223.339.452
21.040
14.329
21.033
15529.027.837.850
18.8388.822
21.031
20037.136.034.947–––
1118.030
31039.838.534.146–––8
17.030
350
Belden 1872ANH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 23. Solid bare copper conductors, polyolefine insulated singles with bonded pairs, ripcord, PVC jacket. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: TIA/EIA 568-B2 , ISO/ IEC 11801
Flame test: UL type CMR, CMG, CM, UL 1666 riser, UL 1581 Vertical Tray, CSA FT4
Belden 1872A MediaTwist ® Bonded pairs Cat. 6
Frequency (MHz)Attenuation (dB/100 m)
PS-NEXT (dB)
PS-ELFEXT (dB)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, Blue, Red, Green,Yellow, Violet, White, BlackVelocity of propagation (%): 70Typ. DCR (Ohm/100 m): 8.2Nominal capacitance (pF/ ft.): 15Diameter of insulated conductor (mm): 0.99
Nominal overall diameter (mm): 8.0Impedance (Ohm): 1 – 20 MHz: 100 ± 12 %
20 – 200 MHz: 100 ± 15 %200 – 250 MHz: 100 ± 20 %250 – 350 MHz: 100 ± 22 %
guaranteed max.typical
guaranteed min.typical
guaranteed min.typical
guaranteed min.typical
guaranteed min.typical
2.01.872.386
64.882
72.384
20.029
1
Standard lengths (put-ups): Standard weight:1000 ft. 305 m 13.2 kg
A 1000 ft. A 305 m 13.2 kg
4.13.663.376
52.772
61.273
23.031
46.55.857.370
44.866
52.865
25.034
108.27.454.369
40.762
48.062
25.034
169.38.452.868
38.760
45.559
25.035
2010.49.451.366
36.857
42.957
24.335
2511.710.749.965
34.955
40.253
23.635
31.2517.015.645.460
28.850
30.444
21.535
62.522.020.842.354
24.845
22.333
21.033
10030.425.739.552
20.940
11.127
21.033
15535.031.337.850
18.7384.820
21.031
20039.637.136.348–––
1518.030
25051.146.234.246–––1
17.030
350
Belden 1875GBNH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 24. Stranded tinned copper conductors, polyolefine insulated singles with bonded pairs, PVC jacket. Colour code: see DataTwist® colour code table onpage 14.
Applicable industry standards: TIA/EIA 568-B2 , ISO/ IEC 11801
Flame test: UL CM UL1581 Vertical Tray, CSA FT4
Belden 1875GB MediaTwist ® Bonded pairs Patch Cat. 6
Standard lengths (put-ups): Standard weight:1000 ft. 305 m 14.2 kg
U 1000 ft. U 305 m 14.2 kgA 1000 ft. A 305 m 14.2 kg
Colour code:Pair no. 1 White/Green & GreenPair no. 2 White/Orange & OrangePair no. 3 White/Blue & BluePair no. 4 White/Brown & Brown
10
UTP Category 6
Frequency (MHz)Attenuation (dB/100 m)
PS-NEXT (dB)
PS-ELFEXT (dB)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, Blue, WhiteVelocity of propagation (%): 67Max. DCR (Ohm/100 m): 8.2Nominal capacitance (pF/ ft.): 15.5Diameter of insulated conductor (mm): 1.05
Nominal overall diameter (mm): 8.0Impedance (Ohm): 1 – 25 MHz: 100 ± 12 %
25 – 250 MHz: 100 ± 15 %250 – 350 MHz: 100 ± 20 %350 – 600 MHz: 100 ± 22 %
max. (TIA /EIA Cat. 6)guaranteed max.
min.guaranteed min.
min.guaranteed min.
min.guaranteed min.
min.guaranteed min.
2.01.972.380.364.870.870.378.420.020.0
13.83.663.371.352.858.859.567.723.023.0
46.05.757.365.344.850.851.359.625.025.0
107.67.254.262.340.746.746.755.125.025.0
168.58.152.860.838.844.844.352.725.025.0
209.59.151.359.336.842.841.850.224.325.0
2510.710.249.957.934.940.939.247.723.625.0
31.2515.414.745.453.428.934.930.038.721.525.0
62.519.818.942.350.324.830.822.531.420.125.0
10025.223.939.447.521.027.014.323.618.822.8
15529.027.537.845.818.824.88.818.318.021.6
20032.831.236.344.316.822.83.513.117.320.5
25039.837.734.140.213.919.9
–4.516.319.8
35043.040.633.339.312.818.8
–0.615.919.5
40048.946.231.837.810.816.8
––
15.218.4
50054.551.430.636.69.215.2
––
14.717.6
600
Belden 7851ANH Halogen-free version Product description
Unshielded Twisted Pair Cable, 4 pairs x AWG 23. Solid bare copper conductors, polyolefine insulated singles with bonded pairs, e-Spline, ripcord, PVC jacket.
Applicable industry standards: TIA/EIA 568-B2
Flame test: UL type CMR, UL1666 riser listed, CSA FT4
Belden 7851A DataTwist ® 600e Bonded pairs Cat. 6
The DataTwist ® 600e cable is a revolutionary UTP cable engineeredspecifically to perform well beyond proposed Category 6 standards.While proposed Category 6 cable is specified only to 250 MHz,DataTwist ® 600e is the only UTP cable in the industry fully char-acterized with guaranteed performance to 600 MHz. So usershave far more headroom to compensate for unforeseen factorsthat can inhibit the performance of a cabling system today... andprotection of their technology investment for the future.
The Cable Preparation Tool is packed with every spool of Belden DataTwist 600e data cable. The Belden Cable Preparation Tool (1797B) now makes it faster and easier than ever to prepare cables for connector termination. This tool is ideal for use with Belden’s Bonded Pair cables, providing special features that help separate twisted pairs. It can also be used to prepare any unbonded pair cablefor installation.
Pair Separation Techniques:Belden’s Cable Preparation Tool features both the new Pick tech-nique and the traditional Blade Slot technique to better facilitate pairuntwisting. The Pick technique utilizes a steel awl that is incorporatedinto the tip of the tool that is surrounded on both sides with guards
to assist in pair alignment during thepair separation step. The Pick
technique allows for a simple“pick-n-pull” motion to
easily separate the con-ductors of a twistedpair cable. The BladeSlot Technique pro-vides the technicianan alternate methodfor separating theconductors quicklyand easily. SeeTB177 for detailed
instructions for eithertechnique.
Belden Data CablesBelden Data Cables
11
(S)FTP Category 5E
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 94Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 1.05
Nominal overall diameter (mm): 6.0Impedance (Ohm): 100 Ohm ± 15 %Energy of flame (kJ/m):
Single TwinE 515 1030ENH 500 1000
Belden 1633ENH Halogen-free version
Belden 1668E Twin version of 1633E
Belden 1668ENH Twin version of 1633ENH
Product description
Shielded Twisted Pair Cable, 4 pairs x AWG 24. Solid bare copper conductors, polyolefine insulation,overall foil shield, tinned copper drain wire. Colour code: see DataTwist® colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 5E)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.02.0607057686173
56.068
53.066
20.033
4.03.8566253604961
52.358
49.356
23.034
5.75.5525849564355
46.153
43.151
24.540
6.36.0505747554153
44.051
41.049
25.042
8.07.6475444523747
39.246
36.244
25.042
9.08.5465243503545
36.844
33.842
25.041
10.19.5445041483343
34.241
31.239
24.338
11.410.8434940473141
31.538
28.536
23.635
16.515.0384535432537
21.830
18.828
21.532
21.319.3354332412133
14.024
11.022
20.129
1 4 8 10 16 20 25 31.25 62.5 100
Standard lengths (put-ups): Standard weight:1000 ft. 305 m 13.0 kg1640 ft. 500 m 21.5 kg3280 ft. 1000 m 43.0 kg
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 66Max. DCR (Ohm/km): 82Nominal capacitance (pF/m): 14Diameter of insulated conductor (mm): 1.06
Nominal overall diameter (mm): 6.7Impedance (Ohm): 100 Ohm ± 15 %
Standard lengths (put-ups): Standard weight:U 1000 ft. U 305 m 14.3 kg
1000 ft. 305 m 16.2 kg3280 ft. 1000 m 53.2 kg
Belden 1633E Cat. 5E
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
RL (dB)
Belden 1730ANH Halogen-free version Product description
Shielded Twisted Pair Cable, 4 bonded pairs x AWG 24. Solid bare copper conductors, polyolefine insulation, lateral foil shield, spiral tinned copper drain wire, Nylon ripcord, PVC jacket. Colour code:see DataTwist® colour code table on page 14.
Applicable industry standards: ISO/ IEC 11801
max. (Cat. 5E)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.960706173
56.068
20.023
1
Belden 1730A Bonded pairs Cat. 5E
4.03.756614961
52.357
23.023
45.75.252564355
46.151
24.523
86.35.850554153
44.049
25.023
108.07.447523747
39.245
25.023
169.08.346503545
36.842
25.023
2011.410.443483141
31.538
23.621
31.2516.514.738432537
21.828
21.518
62.521.319.535402133
14.021
20.116
100
12
(S)FTP Category 5E
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 94Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 1.05
Nominal overall diameter (mm): 6.3Impedance (Ohm): 100 Ohm ± 15 %Energy of flame (kJ/m):
Single TwinE 525 1050ENH 505 1010
Belden 1633ENH+ Halogen-free version
Belden 1668E+ Twin version of 1633E+
Belden 1668ENH+ Twin version of 1633ENH+
Product description
Shielded Twisted Pair Cable. 4 pairs x AWG 24. Solid bare copper conductors, polyolefine insulation,overall foil shield, tinned copper drain wire and tinned copper braid. Colour code: see DataTwist®
colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 5E)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.02.0607057686173
56.068
53.066
20.033
4.03.8566253604961
52.358
49.356
23.034
5.75.5525849564355
46.153
43.151
24.540
6.36.0505747554153
44.051
41.049
25.042
8.07.6475444523747
39.246
36.244
25.042
9.08.5465243503545
36.844
33.842
25.041
10.19.5445041483343
34.241
31.239
24.338
11.410.8434940473141
31.538
28.536
23.635
16.515.0384535432537
21.830
18.828
21.532
21.319.3354332412133
14.024
11.022
20.129
1 4 8 10 16 20 25 31.25 62.5 100
Standard lengths (put-ups): Standard weight:1000 ft. 305 m 14.6 kg1640 ft. 500 m 24.0 kg3280 ft. 1000 m 48.0 kg
Belden 1633E+ Braided Cat. 5E
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, Blue, Red, Green, YellowTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 135Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 0.95
Nominal overall diameter (mm): 5.2Impedance (Ohm): 100 Ohm ± 15 %Energy of flame (kJ/m):
SingleE 370ENH 355
Belden 1868ENH Halogen-free version Product description
Shielded Twisted Pair Cable, 4 pairs x AWG 26. Stranded bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain. Colour code: see DataTwist® colour code tableon page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 5E)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.02.5606957676177
56.067
53.065
20.032
6.05.0566053584965
50.355
47.353
23.033
8.57.0525649544359
43.349
40.347
24.541
9.57.9505447524157
40.846
37.844
25.042
12.19.9475144493753
35.241
32.239
25.041
13.611.1465043483551
32.239
29.237
25.040
15.212.5444841463349
29.136
26.134
24.337
17.114.0434740453147
25.833
22.831
23.633
24.820.5384235402540
13.622
10.620
21.530
32.026.33539323721363.3130.311
20.127
1 4 8 10 16 20 25 31.25 62.5 100
Standard lengths (put-ups): Standard weight:1000 ft. 305 m 8.3 kg1640 ft. 500 m 13.5 kg3280 ft. 1000 m 27.0 kg
Belden 1868E Patch Cat. 5E
Belden Data CablesBelden Data Cables
13
(S)FTP Category 6
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 91Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 1.17
Nominal overall diameter (mm): 7.2Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 22 %Energy of flame (kJ/m):
SingleE 560ENH 540
Belden 7860ENH Halogen-free version Product description
Shielded twisted pair cable, 4 bonded pairs x AWG 23. Solid bare copper conductors, polyolefine insulation, overall foil shield and tinned copper drain wire. Colour code: see DataTwist® colour codetable on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 6)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.9698067786570
65.078
63.076
20.030
4.03.5657663745364
61.373
59.371
23.035
6.05.5597057684557
53.365
51.363
25.040
7.66.9566754654151
48.660
46.658
25.044
8.57.6556653643949
46.358
44.356
25.044
9.68.6536451623747
43.855
41.853
24.344
10.79.7526350613545
41.153
39.151
23.644
15.513.8475845562939
31.944
29.942
21.534
19.917.7445542532535
24.437
22.435
20.130
25.322.4415139492131
16.129
14.127
18.825
1 4 10 16 20 25 31.25 62.5 100 15529.125.1404938471929
10.6248.622
18.024
20033.028.23845364317275.3173.315
17.324
250
Standard lengths (put-ups): Standard weight:1640 ft. 500 m 24.9 kg3280 ft. 1000 m 50.0 kg
Belden 7860E Bonded pairs Cat. 6
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: Grey, BlueTypical velocity of propagation (%): 70Max. DCR (Ohm/km): 91Nominal capacitance (pF/m): 50Diameter of insulated conductor (mm): 1.17
Nominal overall diameter (mm): 7.5Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 22 %Energy of flame (kJ/m):
SingleE 560ENH 540
Belden 7860ENH+ Halogen-free version Product description
Shielded twisted pair cable, 4 bonded pairs x AWG 23. Solid bare copper conductors, polyolefine insulation, overall foil shield and tinned copper drain wire and tinned copper braid. Colour code:see DataTwist® colour code table on page 14.
Applicable industry standards: EN 50173, ISO/ IEC 11801, TIA/EIA 568-B2
max. (Cat. 6)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
4.01.9698067786570
65.078
63.076
20.030
4.03.5657663745364
61.373
59.371
23.035
6.05.5597057684557
53.365
51.363
25.040
7.66.9566754654151
48.660
46.658
25.044
8.57.6556653643949
46.358
44.356
25.044
9.68.6536451623747
43.855
41.853
24.344
10.79.7526350613545
41.153
39.151
23.644
15.513.8475845562939
31.944
29.942
21.534
19.917.7445542532535
24.437
22.435
20.130
25.322.4415139492131
16.129
14.127
18.825
1 4 10 16 20 25 31.25 62.5 100 15529.125.1404938471929
10.6248.622
18.024
20033.028.23845364317275.3173.315
17.324
250
Standard lengths (put-ups): Standard weight:1640 ft. 500 m 28.5 kg3280 ft. 1000 m 56.9 kg
Belden 7860E+ Bonded pairs Braided Cat. 6
Page6666778899101011111112121213131414
ISTP Category 7
14
Frequency (MHz)Attenuation (dB/100 m)
NEXT (dB)
PS-NEXT (dB)
PS-ELFEXT (dB)
ACR (dB/100 m)
PS-ACR (dB/100 m)
RL (dB)
Number of pairs: 4Standard colour: GreyVelocity of propagation (%): 75Max. DCR (Ohm/km): 75Nominal capacitance (pF/m): 48Diameter of insulated conductor (mm): 1.45
Nominal overall diameter (mm): 8.0Impedance (Ohm): 1 – 100 MHz: 100 ± 15 %
100 – 250 MHz: 100 ± 22 %250 – 600 MHz: 100 ± 25 %
Energy of flame (kJ/m):Single Twin
ENH 500 1000
Belden 1887ENH Twin version of 1885ENH Product description
Shielded Twisted Pair Cable, 4 pairs x AWG 23. Solid bare copper, foam skin polyolefin insulated,pairs individually shielded with Aluminum/Polyester foil, overall tinned copper braid, ripcord, flameretardant NH jacket. Colour code: see DataTwist® colour code table below.
Applicable industry standards: EN 50173, ISO/ IEC 11801
max. (Cat. 7)typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typicalmin.
typical
2.01.980
10077987595
76.098
73.096
20.026
3.73.580
10077987595
76.097
73.095
23.030
5.95.48010077987195
74.195
71.193
25.035
7.46.98010077986790
72.693
69.691
25.035
8.57.68010077986587
71.592
68.590
25.035
10.49.68010077986184
69.690
66.688
23.734
14.913.67510072985580
60.186
57.184
21.532
19.017.4729569935176
53.078
50.076
20.131
24.021.7709567934772
46.073
43.071
18.829
27.524.7689565934570
40.570
37.568
17.329
1 4 10 16 20 31.2 62.5 100 155 20034.230.5659062884165
30.860
27.858
17.328
30050.144.6619058883550
10.9457.943
17.328
600
Standard lengths (put-ups): Standard weight:1640 ft. 500 m 30.0 kg3280 ft. 1000 m 60.0 kg
Belden 1885ENH Halogen-free Cat. 7
1583E, 1583ENH1667E, 1667ENH1700E, 1700ENH1702E, 1702ENH1592A*1752A*7965E, 7965ENH7812E, 7812ENH1872A, 1872ANH1875GB*7851A, 7851ANH1797B1633E, 1633ENH1668E, 1668ENH1730A, 1730ANH1633E+, 1633ENH+1668E+, 1668ENH+1868E, 1868ENH7860E, 7860ENH7860E+, 7860ENH+1885ENH1887ENH
Belden part numberU-305 m, 305 m, 500 m, 1000 m305 m, 500 m, 1000 mU-305 m, 305 m, 500 m, 1000 m305 m, 500 m, 1000 mU-305 m, 305 m U-305 m, 305 m 500 m, 1000 mU-305 m, 500 m, 1000 m100 m, A-305 mA-305 m, 305 mA-305 m, U-305 m, 305 m
305 m, 500 m, 1000 m305 m, 500 m, 1000 mU-305 m, 305 m, 1000 m305 m, 500 m, 1000 m305 m, 500 m, 1000 m305 m, 500 m, 1000 m500 m, 1000 m500 m, 1000 m500 m, 1000 m500 m, 1000 m
Standard lengths (put-ups)Grey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032)Grey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032)Grey, Blue, Red, Green, Yellow, Orange, Violet, White, BlackGrey, Blue, Red, Green, Yellow, Orange, Violet, White, BlackGrey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032), Blue (RAL 5015)Grey, Gold, Brown, Blue, Red, Green, Yellow, Orange, VioletGrey, Blue, Red, Green, Yellow, Violet, White, BlackGrey, Blue, WhiteCable preparation tool (White)Grey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032)Grey, BlueGrey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032)Grey, Blue, Red, Green, YellowGrey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032), Blue (RAL 5015)Grey (RAL 7032)Grey (RAL 7032)
Colour
DataTwist ® colour code table:Pair no. 1 White/Blue & BluePair no. 2 White/Orange & OrangePair no. 3 White/Green & GreenPair no. 4 White/Brown & Brown
Notes:● Special put-ups available upon request.● Packaging on non-returnable reels, unreel
box (U-305 m) or reel in box (A-305 m).
Ordering Information & DataTwist ® Colour Code Table
* Halogen-free version available upon request.
Belden across the globe
05
.02
.5
00
0
Cop
yrig
ht©
Bel
den
Inc.
Rep
rintin
g an
d r
epro
duc
tion,
in w
hole
or
in p
art,
pro
hib
ited
.
HungaryBelden – Dunakabel Kft.Hengermalom Str. 431116 BudapestHungaryPhone: +36 1206 1987Fax: +36 1206 1986
ItalyBelden International Inc.Via Paracelso 26Centro Direzionale Colleoni Palazzo Cassiopea Ingr. 320041 Agrate Brianza (MI)ItalyPhone: +39 039 6560911Fax: +39 039 6560929
RussiaBelden Office MoscowUL. Gubkina, 8 117333 Moscow RussiaPhone/Fax: +7 095 938 2754
SpainBelden ElectronicsTorreon, 34P.O. Box 1028260 Galapagar (Madrid)SpainPhone: +34 91 858 7620Fax: +34 91 858 7621
SwedenBelden Wire & Cable B.V.Stadshusplatsen 214930 NynäshamnSwedenPhone: +46 8 52010275Fax: +46 8 52010276
Europe:The NetherlandsBelden Wire & Cable B.V.Edisonstraat 95928 PG VenloThe Netherlands(Headquarters)Phone: +31 77 3878555Fax: +31 77 3878448
AustriaBelden Wire & Cable B.V.Zweigniederlassung ÖsterreichInkustraße 1 – 7/83400 KlosterneuburgAustriaPhone: +43 2243 22993Fax: +43 2243 2299340
GermanyBelden – EIW GmbHAm Krebsgraben 1– 378048 Villingen-SchwenningenGermany
Belden InfolinePhone: +49 2137 929010Fax: +49 2137 929012
FranceBelden Electronics S.A.R.L.Immeuble Le César20, Place Louis Pradel69001 LyonFrancePhone: +33 472 109990Fax: +33 478 298409
Great BritainBelden UK Top Office10, Watergate RowWatergate StreetChester, CheshireCH1 2LDGreat BritainPhone: +44 1244 350535Fax: +44 1244 350635
World-wide:Africa /Middle EastBelden Wire & CableDubai Internet CityBuilding One, Suite 216P.O. Box 500158DubaiUnited Arab EmiratesPhone: +971 4 391 0490Fax: +971 4 391 8775
AustraliaBelden Australia Pty. Ltd.Olympia StreetTottenham, Victoria 3012AustraliaPhone: +61 3 9224 2800Fax: +61 3 9314 8515
CanadaBelden Canada Inc.130 Willmott StreetCobourg, OntarioCanada K9A 4M3Phone: +905 372 8713Fax: +905 372 6291
SingaporeBelden International, Inc.101 Thompson Road, #07-02United SquareSingapore 307591Phone: +01165 251 8211Fax: +01165 251 5010
USABelden Wire & Cable Co.P.O. Box 1980Richmond, IN 47375United StatesPhone: +1 765 983 5200Fax: +1 765 983 5294
All sales of Belden products are subject to Belden’s terms and conditions of sale.All printing errors are subject to correction.Technical specifications are subject to change without notice.
The author reserves the right not to be responsible for the topicality, correctness, comple-teness or quality of the information provided. Liability claims regarding damage caused bythe use of any information provided, including any kind of information which is incompleteor incorrect, will therefore be rejected.
Internet: www.belden.comE-mail: [email protected]
Distributed by:
ITALY ✗ UK