38
DAQ/FLES Summary DAQ/FLES Summary Walter F.J. Müller, GSI, Darmstadt CBM Collaboration Meeting 16 April 2010

DAQ/FLES Summary

  • Upload
    corbin

  • View
    70

  • Download
    0

Embed Size (px)

DESCRIPTION

DAQ/FLES Summary. Walter F.J. Müller , GSI, Darmstadt CBM Collaboration Meeting 16 April 2010. Scope of Summary. Joint summary of DAQ aspects of FEE/DAQ Workshop, 22/23 February at GSI DAQ/FLES Working Group this CBM week. FEE/DAQ WS. DAQ/FLES WG. The CBM Generic Read-out Chain. - PowerPoint PPT Presentation

Citation preview

Page 1: DAQ/FLES Summary

DAQ/FLES SummaryDAQ/FLES Summary

Walter F.J. Müller, GSI, Darmstadt

CBM Collaboration Meeting16 April 2010

Page 2: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 2

Scope of SummaryScope of Summary

Joint summary of DAQ aspects of

FEE/DAQ Workshop, 22/23 February at GSI

DAQ/FLES Working Group this CBM week

FEE/DAQ WSFEE/DAQ WS

DAQ/FLES WGDAQ/FLES WG

Page 3: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 3

The CBM Generic Read-out The CBM Generic Read-out ChainChainDetectorFront-End

BoardRead-OutController

Active BufferBoard

FEB ROC ABB

Data CombinerBoard

DCB

First LevelEvent Selector

FLES

TNet

Data

Control

Data &Control

Sync

Data

DigitizationCustom ASIC

FEE DAQInterfaceLocal Pre-Processing

BufferingSystem

Synchronization

DAQFLESInterface

FPGA Coprocessor

Event SelectionCPU Farm

DAQDetector Sub-System FLES

Page 4: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 4

Mission Statement FEE/DAQ Mission Statement FEE/DAQ WorkshopWorkshop

Focus is on system aspects of the final system Interim solutions, like n-XYTER, should only be covered

in a 'lessons learned from' context.

FEE/DAQ WSFEE/DAQ WS

Page 5: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 5

Agenda FEE/DAQ WorkshopAgenda FEE/DAQ Workshop

Monday morning: TOF (PADI/GET4 readout) afternoon: TRD/MUCH ('Gas'-XYTER readout)

Tuesday morning: STS ('Si'-XYTER readout) afternoon: MVD/RICH

DAQ/FLES

Full program and presentations seehttp://cbm-wiki.gsi.de/cgi-bin/view/DAQ/Workshop-2010-02

FEE/DAQ WSFEE/DAQ WS

Page 6: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 6

FLESFLES

Page 7: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 7

Options for CBM FLES LocationOptions for CBM FLES Location

CBM CBM ServiceServiceBuildingBuilding

~350m

linear dist.

Distance is Distance is preliminary!!preliminary!!

'Green Cube''Green Cube'

Page 8: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 8Slide: J. de CuvelandSlide: J. de Cuveland

DAQ/FLES WGDAQ/FLES WG

Page 9: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 9Slide: J. de CuvelandSlide: J. de Cuveland

DAQ/FLES WGDAQ/FLES WG

Page 10: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 10Slide: J. de CuvelandSlide: J. de Cuveland

DAQ/FLES WGDAQ/FLES WG

Page 11: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 11Slide: J. de CuvelandSlide: J. de Cuveland

DAQ/FLES WGDAQ/FLES WG

Page 12: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 12Slide: J. de CuvelandSlide: J. de Cuveland

DAQ/FLES WGDAQ/FLES WG

Page 13: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 13Slide: J. de CuvelandSlide: J. de Cuveland

DAQ/FLES WGDAQ/FLES WG

Page 14: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 14

DABCInfiniBand performance tests (2006-2007)

Slide: S. Linev Slide: S. Linev

DAQ/FLES WGDAQ/FLES WG

Page 15: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 15

CBM RadiationCBM RadiationEnvironmentEnvironment

Page 16: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 16

STS Plane 1 (30cm) – TID STS Plane 1 (30cm) – TID

FEE

Aux

no MUCH

at FEE: ~200krad/yrat Aux: ~50krad/yr

ProvisoProviso: preliminaryFLUKA calculations !

FEE/DAQ WSFEE/DAQ WS

Page 17: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 17

STS Plane 8 (100cm) – fast STS Plane 8 (100cm) – fast hadron fluxhadron flux

FEE

with MUCH

2·103 h/cm2/s

2·104 h/cm2/s

2·105 h/cm2/s

at FEE: ~105 h/cm2/s

ProvisoProviso: preliminaryFLUKA calculations !

FEE/DAQ WSFEE/DAQ WS

Page 18: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 18

Physical Location View – Feb Physical Location View – Feb 2222ndnd

FEB ROC/DCS ABBDCB FLES

TNet

Data

Control

Data &Control

Sync

Data

Cu

optical

Data

Control

ST

S,..

..T

OF

, ...?

ROC

ECS

on/near Detector CBM Service Bldg. GSI/FAIR IT Bldg.

Data

~50m~50m ~500m~500m

??

FEE/DAQ WSFEE/DAQ WS

Page 19: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 19

Closer lookCloser lookat STS readoutat STS readout

Page 20: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 20

STS Hit Rates per 128 Channel STS Hit Rates per 128 Channel ChipChip

Hit rate [MHz]

Sta0

Sta 1

Sta 2

Sta 3

Sta 4

Sta 5

Sta 6

Sta 7

Total

32-64 21 14 9 1 0 0 0 0 45

16-32 67 72 157 116 73 60 1 1 547

8-16 208 357 477 555 325 430 157 189 2698

4-8 494 521 250 440 964 785 1048

753 5255

2-4 441 376 51 24 219 294 693 1079

3177

1-2 104 51 0 0 3 5 21 90 274

0.5-1 1 1 0 0 0 4 0 0 6

Total 1336 1392 944 1136 1584 1578

1920

2112

12002

Very few chip in inner region have hit rate > 32 MHz >90% of chips have hit rates in 2...16 MHz range

Hit rate per chip StatisticsHit rate per chip StatisticsAu+Au @ 25 AGevAu+Au @ 25 AGev

101077 evt/sec evt/sec

FEE/DAQ WSFEE/DAQ WS

SIM-Data: A. KotyniaSIM-Data: A. Kotynia

Page 21: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 21

STS QuadrantSTS Quadrant

6 cm6 cm5 cm5 cm

STS-FEBs

Is this enough space for: - 117 copper links - 10 opto converters - 10 ribbon fiber cablesplus other services like - power distribution - control & monitoring - ,,,,,,,

size of asize of a

post cardpost card

FEE/DAQ WSFEE/DAQ WS

CAD: S. Belogurov et alCAD: S. Belogurov et al

Page 22: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 22

Compact electro-optics Converts Compact electro-optics Converts II

Optically enabled ASIC

Use MT connector:12 x TX

or 12 x RX or 4xTX and 4xRX

Optically enabled FPGA

Extracted from ReflexPhotonicsWhite Papers and Presentations

Claim for 12 channels:

4 cm2 footprint3 mm height

LightABLE from ReflexPhotonicsLightABLE from ReflexPhotonics

FEE/DAQ WSFEE/DAQ WS

Page 23: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 23

Some Data on Fiber Ribbon Some Data on Fiber Ribbon CableCable Assume 12 fiber ribbon cable

very compact, 20 mil pitch cable cross section: 2.3 x 5.1 mm

Assume MPO/MPT connector

2.3

mm

5.1 mm

Pictures from GORE

FEE/DAQ WSFEE/DAQ WS

Page 24: DAQ/FLES Summary

24Ulrich Brüning

STS Interface Converter STS Interface Converter BoardBoard

Proposal for STS interfacing2m copper twinax x1, x2, x4 or

x8copper => optical on Postcard

12.7cm x 8.9cmConversion to optical signals

with AOCs

Does electrical and AOC connector fit on one Postcard ?

Connector density analysis

AOCconnectors

twinaxconnectors

twinaxconnectors

Passive BoardPostcard

miniHTconnector

Slide: U. BrueningSlide: U. Bruening

FEE/DAQ WSFEE/DAQ WS

Page 25: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 25

ProvisoProviso:link counts likely to go up to

account for more background,

overhead, head room,....

All STS data can be transported by ~280 ribbon cables Corresponds to 34 cm2 cable cross section

STS Link & Ribbon Cable STS Link & Ribbon Cable DistributionDistribution

Sta0

Sta 1

Sta 2

Sta 3

Sta 4

Sta 5

Sta 6

Sta 7

total

FEBs 168 176 120 144 200 200 240 264 1512

links 361 417 443 459 425 426 347 336 3214

cables/quadrant 8 9 10 10 9 9 8 7

cables tot 32 36 40 40 36 36 32 28 280

FEB&Cable StatisticsFEB&Cable StatisticsAu+Au @ 25 AGevAu+Au @ 25 AGev

101077 evt/sec evt/sec48 bit message48 bit message

FEE/DAQ WSFEE/DAQ WS

Page 26: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 26

Where to locateWhere to locatefast serializers fast serializers

andandopto-converters ?opto-converters ?

Page 27: DAQ/FLES Summary

1212thth – 16 – 16thth April, 2010 April, 2010 1515thth CBM Collaboration Meeting CBM Collaboration Meeting 27

Data Aggregation on separate chip - Data Aggregation on separate chip - Communication hubCommunication hub Motivation:

Data Aggregation: In most cases 2,4, or 8 CBM-XYTER chips (FEBa2, FEBa4, FEBa8, resp.) can be aggregated to fill a 2.5 Gbps link

Increase the bandwidth available per link Reduce the number of Optical Links

Schemes: Embedded (aggregation integrated in CBM-XYTER)

Data aggregation and Traffic Management with a separate Communication Controller Asic

Communication ‘hub’

Clock Distribution Slow control traffic Data Readout traffic

6

DAQ/FLES WGDAQ/FLES WG

Slide: P. BanerjeeSlide: P. Banerjee

Page 28: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 28

All Combined – Detector & All Combined – Detector & Service Bldg.Service Bldg.

Data

Clock &Control

CBM Service Bldg.

DCB

DCS

on/near Detector

Clock &Sync

febfeb hubhub optoopto

TNetCntlNet

Con

trol

Data

DAQ/FLES WGDAQ/FLES WG

Page 29: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 29

STS Quadrant – A possible STS Quadrant – A possible arrangementarrangement

6 cm6 cm5 cm5 cm

STS-FEBs

STS-'hub' STS-'opto'

DAQ/FLES WGDAQ/FLES WG

Page 30: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 30

DCSDCS

DCB

DCS

DCB

DCS

Physical Location View – April Physical Location View – April 1313thth

FEB ABB

DCB

FLES

Data

Control

Clock &Data &Control

Clock &

Sync

Data

ST

S,..

..T

OF

, ...?

ROC

ECS

Cu

optical

on/near Detector CBM Service Bldg. 'Green Cube'

Data

~50m~50m ~500m~500m

Data

Control

'hub' 'opto'Data

Clock & Control

DCB

DCS

CLOSY

DCS

TNet

CntlNet

Clock & Sync

Contro

l

Con

trol

DAQ/FLES WGDAQ/FLES WG

Page 31: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 31

DCSDCS

DCSDCS

Physical Location View – April Physical Location View – April 1515thth

FEB ABB

DCB

FLES

Data

Control

Clock &Data &Control

Clock &

Sync

Data

ST

S,..

..T

OF

, ...?

ROC

ECS

Cu

optical

on/near Detector CBM Service Bldg. 'Green Cube'

Data

~50m~50m ~500m~500m

Data& Control

clock

'hub' 'opto'

CLOSY

DCS

TNet

CntlNet

Clock & Sync

Contro

l

Con

trol

DPB?

DCS

Clock &Data &Control

DAQ/FLES WGDAQ/FLES WG

Page 32: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 32

ROC next GenROC next Gen

Page 33: DAQ/FLES Summary

33

Basic Components on FPGA Module

Xilinx FPGA (Spartan, Virtex)

RAM

Actel Configuration Controller

Flash EEPROM

Voltage Regulators (1.2, 1.5, ...) driven by 3.3 V or 5V

RS232 Interface

1 or 2 SFPs

Jitter Cleaner

FMC-HPC (Vita57) connector with (160 or) 400 pins

Slide: D. GottschalkSlide: D. Gottschalk

FEE/DAQ WSFEE/DAQ WS

Page 34: DAQ/FLES Summary

34

SysCore 3 Base Board Example

32 RJ45 Connectorswith LVDS

48Volt Power Input

Isolated JTAG forHigh Voltage Applications

External Ref. ClockInputs (LVDS??)

Gigabit LinksSFPs or electrically

USB + GBit Ethernet

Slide: D. GottschalkSlide: D. Gottschalk

FEE/DAQ WSFEE/DAQ WS

Page 35: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 35

ControlsControls

Page 36: DAQ/FLES Summary

13.04.201013.04.2010 Burkhard Kolb GSIBurkhard Kolb GSI 3636

Test beam time exampleTest beam time example

Burkhard Kolb GSIBurkhard Kolb GSI 3636

DAQ/FLES WGDAQ/FLES WG

Slide: B. KolbSlide: B. Kolb

Page 37: DAQ/FLES Summary

13.04.201013.04.2010 Burkhard Kolb GSIBurkhard Kolb GSI 3737Burkhard Kolb GSIBurkhard Kolb GSI 3737

Requirements DBRequirements DB

In collaboration with PANDA we have set up a database with web access

http://nuclear.gla.ac.uk/CBM-DCS/RegisterThen enter requirements:

Process variablesCommon hardware…

In collaboration with PANDA we have set up a database with web access

http://nuclear.gla.ac.uk/CBM-DCS/RegisterThen enter requirements:

Process variablesCommon hardware…

DAQ/FLES WGDAQ/FLES WG

Slide: B. KolbSlide: B. Kolb

Page 38: DAQ/FLES Summary

16 Apr 2010 CBM Collaboration Meeting -- Walter F.J. Müller, GSI 38

The EndThe End

Thanks for Thanks for your attentionyour attention