20
DAO 35 Lugod, Cyril Benedict V.

DAO 35

Embed Size (px)

DESCRIPTION

DENR 35

Citation preview

DAO 35

DAO 35Lugod, Cyril Benedict V.DAO 35DENR Administrative Order No. 35pursuant to provisions of Sec. 6 of PD 984 (Pollution Control Decree of 1976)revised effluent regulations of 1990revision and amendments of the effluent regulations of 1982it concerns all industrial and municipal wastewater effluents

DefinitionsBOD- measure of approximate quantity of dissolved oxygen needed by bacteria to stabilize organic matter in the wastewaterCoastal Water- open body of water along the coastline up to the 200-m isobath or 3-km distance, whichever is fartherEffluent- any wastewater in its natural state issuing from a plant

DefinitionsMixing Zone- place where effluent discharge from a source mixes with the receiving body of waterStrong Water- wastewater whose initial BOD value before treatment is equal or greater than 3000mg/L

Heavy Metals and Toxic Substancesclassified as Class A, B, C, D, SA, SB, SC, and SD depending on the values of the following parameters

Conventional and Other Pollutants Affecting Aesthetics and Oxygen Demandclassified as Class A, B, C, D, SA, SB, SC, and SD depending on the values of the following parameters

Effluent Standards for BOD for Strong Industrial Wastesfor strong industrial wastewaters with high BOD and where the receiving body of water is Class C, D, SC, and SD, these rules and regulations apply

Mixing Zone Requirementsthe designated uses of the receiving body of water shall not be significantly impairedit shall not include an existing drinking water intakeit shall not create a barrier of migration of aquatic life

Mixing Zone Requirementsit shall not include a nursery area of indigenous aquatic life, shellfish farm, tourist zone, and national marine parkslength should be as short as possible and its width shall preferably be not more than half the width of the waterwayMixing Zone Requirementsin discharging hot effluents from power plants, ore milling, and similar generators of large volume of liquid wastes, the permissible size of the mixing zone shall be determined through modelling taking into consideration the size, hydraulic and hydrological data of the receiving body, and the design of the wastewater outfallit must not be used as a substitute for wastewater treatment facility

Prohibitionsno industrial or domestic sewage effluents shall be discharged into Class AA and SA watersno new industrial plant with high waste load potential shall discharge into a body of water where dilution capacity during dry weather is insufficient to maintain prescribed water qualityProhibitionsno person shall discharge wholly or partially untreated industrial effluents into bodies of water

Sourcehttp://www.emb.gov.ph/portal/Portals/0/Cache/DAO%201990-35.pdf