10
DAISY HILL SOLAR FARM HIL1A - DEVELOPMENT APPLICATION ADDRESS: CLIENT: ITP DEVELOPMENTS HILLSTON RACECOURSE RD NSW 2675 Sheet List Table SHEET NUMBER SHEET NAME G-010 MAIN TITLE G-040 LOCATION PLAN G-210 GENERAL ARRANGEMENT PLAN C-130 SITE ELEVATION C-430 INVERTER STATION FOOTING DETAIL C-530 TYPICAL FENCING DETAIL C-630 ACCESS ROAD DETAIL E-341 TYPICAL NEXTRACKER ARRAY DETAIL E-430 TYPICAL INVERTER STATION DETAIL E-530 TYPICAL BESS DETAIL

DAISY HILL SOLAR FARM - Carrathool Shire

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

E-530 TYPICAL BESS DETAILC-530 TYPICAL FENCING DETAIL
C-630 ACCESS ROAD DETAIL
E-530 TYPICAL BESS DETAIL
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\G-040 LOCATION PLAN.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:16 PM
DAISY HILL SOLAR FARM
PROPOSED CAR PARK SPACE
DURING CONSTRUCTION (STAGE 2)
16.5 m
22.3 m
13.4 m
1
C-130
1
C-130
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\G-210 GENERAL ARRANGEMENT PLAN.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:16 PM
DAISY HILL SOLAR FARM
LGA CARRATHOOL SHIRE COUNCIL
LAT / LONG -33.51501 / 145.53487
FENCED AREA 11.3 ha (STAGE 1) / 11.1 ha (STAGE 2)
DNSP ESSENTIAL ENERGY
AC CAPACITY 5.0 MW (STAGE 1) / 5.0 MW (STAGE 2)
INVERTERS 2 x 2.5 MW AC (STAGE 1)
2 x 2.5 MW AC (STAGE 2)
TRACKER 3 STRINGS, 85.2 m
TRACKER SPACING (N-S) 8 m
ARRAY PITCH 6 m
CONNECTION VOLTAGE 33 kV
CONNECTION SUBSTATION ESSENTIAL ENERGY HILLSTON 132/33
ZONE
ARRAY SETBACK 6 m FROM SECURITY FENCE
ACCESS ROAD WIDTH 8 m
2
2
ARRAY SECURITY FENCE
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\C-130 SITE ELEVATION.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
15.7 m 272.6 m
INVERTER STATION BASE
TO CONFIRMATION BY STRUCTURAL
BY STRUCTURAL ENGINEER
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\C - 430 INVERTER FOOTING STATION DETAIL.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
SUPPORT CABLES
1.0 AND 1.2kN TENSION
CORNER POST
TWISTED WIRED FIXED TO CRIMPED
POSTS AT 150mm CENTERS
2.50mm GALVANIZED WIRE
(W10Z)
SHALL BE BRACED AT NOT
MORE THAN 150m INTERVALS
°
FENCE AND GATES TO BE DESIGNED AND CONSTRUCTED TO AS 1725 PART 1
SCALE: 1:50
DIAGONAL TWIN 3.15mm
TWISTED CABLE WIRE
WITH 12mm GALVANIZED
SCALE: 1:50
-
1 0 0 0
PAD INSET WITH 2 OF DN25 KEEPERS FOR
DROP BOLTS
BOLTS WELDED TO GATE FRAME
1 8 0 0
2 3 1 0
-
GATE INNER FRAME
1 HORIZONTAL MEMBER AND
GATE POST
3 5 0
GATE OUTER FRAME
GATE INNER FRAME
1 HORIZONTAL MEMBER
TOP DIAGONAL BRACE
GATE POST
TOP CABLE POSITION
BOTTOM CABLE POSITION
NOM. 50 PITCH
NOM. 50 PITCH
2.50 HEAVILY GALV.
WIRE CODE W10Z
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\C-530 TYPICAL FENCING DETAIL.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
40mm MAX CLASS 3 CRUSHED ROCK
BASE COURSE MIN 150mm THICKNESS 55mm MAX
NATURAL GRAVELS, PIT MATERIALS OR QUARRY WASTE
NATURAL SUB-GRADE
SCALE: 1:50
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\C-630 ACCESS ROAD DETAIL.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
-
7221 8230 8230 8230 8230 8034 8034 8230 8234 8230 7221
FINISHED GRADE
SCALE: 1:500
E-341
E-341
48450
88660
40210
E-341
18 MODULES 38 MODULES
E-341
E-340
E-341
E-341
E-341
6
0
STRUCTURAL ENGINEER FOLLOWING
CONCRETE COLLAR MAY BE NECESSARY
1
9
5
9
9 0 0
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\E-341 TYPICAL NEXTRACKER ARRAY DETAIL.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
MEDIUM VOLTAGE
SWITCH GEAR
2
E-430
2
E-430
TRANSFORMER OIL CONTAINMENT
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\E-430 TYPICAL INVERTER STATION DETAIL.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
[email protected]
www.itpau.com.au
OTHERWISE STATED.
USED BY CLIENTS OF ITP OR THOSE
WHO HAVE RECEIVED EXPRESS
THIS DRAWING SHALL NOT EXTEND
BEYOND THE PURPOSE FOR WHICH
IT WAS ORIGINALLY PREPARED.
NOTES
g:\itp solar farm development\a5000 engineering team\6 site-specific work\hil1a hillston 1a\4 system design\4.01 cad\E-530 TYPICAL BESS DETAIL.dwg, PLOTTED BY ISHPREET S. CHAWLA AT 20/12/2019 3:17 PM
DAISY HILL SOLAR FARM
C-530 TYPICAL FENCING DETAIL
C-630 ACCESS ROAD DETAIL
E-530 TYPICAL BESS DETAIL