Upload
jamesmarkchan
View
752
Download
73
Embed Size (px)
DESCRIPTION
DAIKIN SPLIT SYSTEM
Citation preview
1
Series
Ceiling MountedCassete Type
Ceiling Suspended Type
Floor Standing Type
Wall Mounted Type
Capacity Class24 30
Indoor unit
FHC24PEVJ
R24PEVJ
FH24PEVJ
FT30HEVJ
R30HEVJ
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
PRODUCT LINE UP
R24PEVJ
2
36 48 54 60
FHC36PEVJ
R36PEVJ
FH36PEVJ FH60PEVJ
FV54PEVL
R54PBETL
FV36PEVJ
R36PBEVJ
FHC48PEVJ
R48PETJ / R48PEYL
R36PEVJ R60PETJ
Min. 280 mm
All models feature a decoration panel with the same compact size and simple design for easier planning of lighting systems and harmonising of interior décor.
The indoor units weight only 30 kg and require an installation space height of just 280 mm.* For FHC24PEVJ
Standard wireless remote controller
FHC24/36/48PEVJ
R24PEVJ
R36PEVJ R48PETJR48PEYL
3
Specially designed for shallow ceilings - for a smooth, modern interior finish
Ceiling Mounted Cassette Type
Unit ON/OFF
Temperature Setting
Fan Speed Setting(AUTO/LOW/MID/HIGH)
Operation Mode Setting(COOL/DRY/FAN)
Swing Function
Timer Function
Sleep Function
Ceiling Suspended Type
FH24/36/60PEVJ
Slim and sophisticated casing
Auto-swing distributes air across a space
Easy-clean panel
Model lineup from 24,600 to 58,000 Btu/h is available
Standard wireless remote controller
Unit ON/OFF
Temperature Setting
Fan Speed Setting(AUTO/LOW/MID/HIGH)
Operation Mode Setting(COOL/DRY/FAN)
Swing Function
Timer Function
Sleep Function
Slim casing harmonised with your space
R24PEVJ
R36PEVJ R60PETJ
4
Auto swing delivers comfort cooling to the corner of the room.
With wireless remote controller, operation like the LCD panel of the unit is also possible.
FV36PEVJ R36PBEVJ R54PBETLFV54PEVL
• Operation mode• Temperature setting
• Timer setting
• Auto swing
• Fan speed
Easy-to-operate LCD control panel. The LCD displays text, numbers and graphics to indicate the following :
5
WirelessRemote Controller
Floor Standing TypeEasy to install and maintain for shops and offices
Manual setting of vertical airflow louvers
Vertical airflow adjustment is possible with hands.
Auto-swing
R30HEVJWireless
remote controllerFT30HEVJ
6
Wall Mounted TypeThe next step in stylish design
Vertical Auto-Swing (up and down) function automatically moves the flaps up and down to distribute air across a room.
New Powerful Operation boosts airflow to maximum volume. This function is activated by pushing the TURBO button on the remote controller.
The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
The flat panel can be cleaned with only the single pass of a cloth across their smooth surface.
The microprocessor automatically controls fan speed to adjust room temperature to the set temperature. (AUTO / LOW / MIDDLE / HIGH)
24-hour on/off timer can be preset to start and stop at any time within a 24-hour period.
7
Ceiling Mounted Cassette Type
Indoor unit side Outdoor unit sidePower intake
Model name
Power supply
Cooling capacity
Power consumption
Running current
EER
Indoor unit
Dimensions (H x W x D)
Machine weight
Airflow rate
Sound level (H / M / L)
Dimensions (H x W x D)
Machine weight
Sound level
Compressor type
Refrigerant charge (R-22)
Operation range
790 x 980 x 427 1,100 x 1,107 x 440
109
61
Scroll
1,100 x 1,107 x 440
109
61
Scroll
695 x 1,018 x 412
55 68
ø19.1
ø12.7
50
30
ø19.1
ø12.7
50
30
ø19.1
ø12.7
50
30
ø15.9
ø9.5
30
15
BYC48PE
60 x 950 x 950
6.5
56
Outdoor unit
Piping connections
Max. piping length
Max. height difference
Panel
Model name
Dimensions (H x W x D)
Weight
Indoor unit FHC24PEVJ FHC36PEVJ
Outdoor unit R24PEVJ R36PEVJ R48PETJ R48PEYL
FHC48PEVJ
FHC24PEVJ FHC36PEVJ
R24PEVJ R36PEVJ R48PETJ R48PEYL
FHC48PEVJ
VJ: 1 phase, 230V, 60Hz TJ: 3 phase, 230V, 60Hz YL: 3 phase, 380V, 60Hz
24,000
7.0
2.50
12.3
9.60
34,100
10.0
3.45
16.8
9.88
44,700
13.1
5.17
8.65
17.0 9.0
Gas
Liquid
58
Rotary Rotary
2.1 3.4 4.3 4.2
18 to 5218 to 52 18 to 5218 to 52
320 x 840 x 840
34
27.5
52/50/47
240 x 840 x 840
30
20.8
49/47/45
320 x 840 x 840
34
27.5
52/50/47
Btu/h
kW
kW
A
Btu/hW
mm
kg
dB(A)
mm
kg
kg
dB(A)
mm
mm
m
m
mm
kg
˚CDB
m3/min
NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.
SPECIFICATIONS
8
Indoor unit side Outdoor unit sidePower intake
Ceiling Suspended Type
Model name
Power consumption
Running current
EER
Dimensions (H x W x D)
Machine weight
Airflow rate
Sound level (H / M / L)
Dimensions (H x W x D)
Machine weight
Sound level
Compressor type
Refrigerant charge (R-22)
Operation range
Max. piping length
Max. height difference
Chargeless
Indoor unit
RotaryRotary Scroll
18 to 52 18 to 52 18 to 52
Outdoor unit
Piping connections
Indoor unit
Outdoor unit
FH36PEVJ
R36PEVJ
FH60PEVJ
VJ: 1 phase, 230V, 60Hz TJ: 3 phase, 230V, 60Hz
Btu/h
kW
kW
A
Btu/hW
mm
kg
m3/min
dB(A)
mm
kg
dB(A)
kg
˚CDB
mm
mm
m
m
m
Gas
Liquid
FH24PEVJ
R24PEVJ
R36PEVJR24PEVJ
FH36PEVJ FH60PEVJFH24PEVJ
Power supply
NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.
R60PETJ
R60PETJ
24,600
7.2
2.59
12.8
9.52
35,000
10.3
3.57
16.8
9.82
58,000
17.0
6.11
18.7
9.50
245 x1,700 x 700
65
40
59/56/53
245 x1,420 x 700
50
26
49/47/44
245 x1,420 x 700
54
32
55/50/46
695 x1,018 x 412 1,350 x1,150 x 460790 x 980 x 427
6855
55 58 60
134
2.1 3.4 5.6
ø15.9
ø9.5
30
15
7.5
ø19.1
ø12.7
50
30
7.5
ø19.1
ø12.7
50
30
7.5
Cooling capacity
9
Floor Standing Type
Power intake Outdoor unit side
Model name
Power consumption
Running current
EER
Dimensions (H x W x D)
Machine weight
Airflow rate
Sound level (H / M / L)
Dimensions (H x W x D)
Machine weight
Sound level
Compressor type
Refrigerant charge (R-22)
Operation range
Max. piping length
Max. height difference
Chargeless
Indoor unit
Scroll
21 to 43
Scroll
21 to 43
Outdoor unit
Piping connections
Indoor unit
Outdoor unit
FV54PEVL
R54PBETL
R54PBETL
FV54PEVL
VJ: 1 phase, 230V, 60Hz VL: 1 phase, 220V, 60Hz TL: 3 phase, 220V, 60Hz
48,800
14.3
5.80
18.0
8.41
1,850 x 580 x 390
54
34.0
55 / 52 / 48
1,250 x 1,030 x 412
114
61
5.50
ø19.1
ø12.7
30
20
5
Btu/h
kW
kW
A
Btu/hW
mm
kg
m3/min
dB(A)
mm
kg
dB(A)
kg
˚CDB
mm
mm
m
m
m
36,000
10.6
4.10
21.0
8.78
1,750 x 540 x 390
48
27.0
56 / 53 / 51
840 x 1,030 x 410
88
57
3.25
ø19.1
ø12.7
30
20
5
Gas
Liquid
FV36PEVJ
R36PBEVJ
FV36PEVJ
R36PBEVJ
Power supply
NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.
Cooling capacity
SPECIFICATIONS
10
Wall Mounted Type
Model name
Power consumption
Running current
EER
Power supply
Dimensions (H x W x D)
Machine weight
Airflow rate (H)
Sound level (H / M / L )
Factory charge
Gas
Liquid
Dimensions (H x W x D)
Machine weight
Sound level
Compressor type
Refrigerant charge (R-22)
Operation range
Piping connections
Max. piping length
Max. height difference
Chargeless
Outdoor unit
Indoor unit
Outdoor unit
FT30HEVJ
R30HEVJ
Indoor unit FT30HEVJ
R30HEVJ
1 phase, 230V, 60Hz
31,250
8.68
3.35
16.0
9.33
326 x 1,178 x 253
17.5
18.3
49 / 47 / 44
840 x 1,018 x 412
90
57
Rotary
2.50
18 to 43
ø15.9
ø9.5
30
15
7.5
kJ/h
kW
kW
A
kJ/hW
mm
kg
m3/min
dB(A)
mm
kg
dB(A)
kg
˚CDB
m
m
mm
mm
m
Cooling capacity
NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.
All rights reservedPrinted in Japan 02/11/002 AKc
DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of February 2011 but subject to change without notice.