12
PCPPHK1105 R-22 Packaged Air Conditioners Cooling Only [60 Hz]

Daikin Split System

Embed Size (px)

DESCRIPTION

DAIKIN SPLIT SYSTEM

Citation preview

PCPPHK1105

R-22

PackagedAir Conditioners

Cooling Only [60 Hz]

1

Series

Ceiling MountedCassete Type

Ceiling Suspended Type

Floor Standing Type

Wall Mounted Type

Capacity Class24 30

Indoor unit

FHC24PEVJ

R24PEVJ

FH24PEVJ

FT30HEVJ

R30HEVJ

Outdoor unit

Indoor unit

Outdoor unit

Indoor unit

Outdoor unit

Indoor unit

Outdoor unit

PRODUCT LINE UP

R24PEVJ

2

36 48 54 60

FHC36PEVJ

R36PEVJ

FH36PEVJ FH60PEVJ

FV54PEVL

R54PBETL

FV36PEVJ

R36PBEVJ

FHC48PEVJ

R48PETJ / R48PEYL

R36PEVJ R60PETJ

Min. 280 mm

All models feature a decoration panel with the same compact size and simple design for easier planning of lighting systems and harmonising of interior décor.

The indoor units weight only 30 kg and require an installation space height of just 280 mm.* For FHC24PEVJ

Standard wireless remote controller

FHC24/36/48PEVJ

R24PEVJ

R36PEVJ R48PETJR48PEYL

3

Specially designed for shallow ceilings - for a smooth, modern interior finish

Ceiling Mounted Cassette Type

Unit ON/OFF

Temperature Setting

Fan Speed Setting(AUTO/LOW/MID/HIGH)

Operation Mode Setting(COOL/DRY/FAN)

Swing Function

Timer Function

Sleep Function

Ceiling Suspended Type

FH24/36/60PEVJ

Slim and sophisticated casing

Auto-swing distributes air across a space

Easy-clean panel

Model lineup from 24,600 to 58,000 Btu/h is available

Standard wireless remote controller

Unit ON/OFF

Temperature Setting

Fan Speed Setting(AUTO/LOW/MID/HIGH)

Operation Mode Setting(COOL/DRY/FAN)

Swing Function

Timer Function

Sleep Function

Slim casing harmonised with your space

R24PEVJ

R36PEVJ R60PETJ

4

Auto swing delivers comfort cooling to the corner of the room.

With wireless remote controller, operation like the LCD panel of the unit is also possible.

FV36PEVJ R36PBEVJ R54PBETLFV54PEVL

• Operation mode• Temperature setting

• Timer setting

• Auto swing

• Fan speed

Easy-to-operate LCD control panel. The LCD displays text, numbers and graphics to indicate the following :

5

WirelessRemote Controller

Floor Standing TypeEasy to install and maintain for shops and offices

Manual setting of vertical airflow louvers

Vertical airflow adjustment is possible with hands.

Auto-swing

R30HEVJWireless

remote controllerFT30HEVJ

6

Wall Mounted TypeThe next step in stylish design

Vertical Auto-Swing (up and down) function automatically moves the flaps up and down to distribute air across a room.

New Powerful Operation boosts airflow to maximum volume. This function is activated by pushing the TURBO button on the remote controller.

The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.

The flat panel can be cleaned with only the single pass of a cloth across their smooth surface.

The microprocessor automatically controls fan speed to adjust room temperature to the set temperature. (AUTO / LOW / MIDDLE / HIGH)

24-hour on/off timer can be preset to start and stop at any time within a 24-hour period.

7

Ceiling Mounted Cassette Type

Indoor unit side Outdoor unit sidePower intake

Model name

Power supply

Cooling capacity

Power consumption

Running current

EER

Indoor unit

Dimensions (H x W x D)

Machine weight

Airflow rate

Sound level (H / M / L)

Dimensions (H x W x D)

Machine weight

Sound level

Compressor type

Refrigerant charge (R-22)

Operation range

790 x 980 x 427 1,100 x 1,107 x 440

109

61

Scroll

1,100 x 1,107 x 440

109

61

Scroll

695 x 1,018 x 412

55 68

ø19.1

ø12.7

50

30

ø19.1

ø12.7

50

30

ø19.1

ø12.7

50

30

ø15.9

ø9.5

30

15

BYC48PE

60 x 950 x 950

6.5

56

Outdoor unit

Piping connections

Max. piping length

Max. height difference

Panel

Model name

Dimensions (H x W x D)

Weight

Indoor unit FHC24PEVJ FHC36PEVJ

Outdoor unit R24PEVJ R36PEVJ R48PETJ R48PEYL

FHC48PEVJ

FHC24PEVJ FHC36PEVJ

R24PEVJ R36PEVJ R48PETJ R48PEYL

FHC48PEVJ

VJ: 1 phase, 230V, 60Hz TJ: 3 phase, 230V, 60Hz YL: 3 phase, 380V, 60Hz

24,000

7.0

2.50

12.3

9.60

34,100

10.0

3.45

16.8

9.88

44,700

13.1

5.17

8.65

17.0 9.0

Gas

Liquid

58

Rotary Rotary

2.1 3.4 4.3 4.2

18 to 5218 to 52 18 to 5218 to 52

320 x 840 x 840

34

27.5

52/50/47

240 x 840 x 840

30

20.8

49/47/45

320 x 840 x 840

34

27.5

52/50/47

Btu/h

kW

kW

A

Btu/hW

mm

kg

dB(A)

mm

kg

kg

dB(A)

mm

mm

m

m

mm

kg

˚CDB

m3/min

NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.

SPECIFICATIONS

8

Indoor unit side Outdoor unit sidePower intake

Ceiling Suspended Type

Model name

Power consumption

Running current

EER

Dimensions (H x W x D)

Machine weight

Airflow rate

Sound level (H / M / L)

Dimensions (H x W x D)

Machine weight

Sound level

Compressor type

Refrigerant charge (R-22)

Operation range

Max. piping length

Max. height difference

Chargeless

Indoor unit

RotaryRotary Scroll

18 to 52 18 to 52 18 to 52

Outdoor unit

Piping connections

Indoor unit

Outdoor unit

FH36PEVJ

R36PEVJ

FH60PEVJ

VJ: 1 phase, 230V, 60Hz TJ: 3 phase, 230V, 60Hz

Btu/h

kW

kW

A

Btu/hW

mm

kg

m3/min

dB(A)

mm

kg

dB(A)

kg

˚CDB

mm

mm

m

m

m

Gas

Liquid

FH24PEVJ

R24PEVJ

R36PEVJR24PEVJ

FH36PEVJ FH60PEVJFH24PEVJ

Power supply

NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.

R60PETJ

R60PETJ

24,600

7.2

2.59

12.8

9.52

35,000

10.3

3.57

16.8

9.82

58,000

17.0

6.11

18.7

9.50

245 x1,700 x 700

65

40

59/56/53

245 x1,420 x 700

50

26

49/47/44

245 x1,420 x 700

54

32

55/50/46

695 x1,018 x 412 1,350 x1,150 x 460790 x 980 x 427

6855

55 58 60

134

2.1 3.4 5.6

ø15.9

ø9.5

30

15

7.5

ø19.1

ø12.7

50

30

7.5

ø19.1

ø12.7

50

30

7.5

Cooling capacity

9

Floor Standing Type

Power intake Outdoor unit side

Model name

Power consumption

Running current

EER

Dimensions (H x W x D)

Machine weight

Airflow rate

Sound level (H / M / L)

Dimensions (H x W x D)

Machine weight

Sound level

Compressor type

Refrigerant charge (R-22)

Operation range

Max. piping length

Max. height difference

Chargeless

Indoor unit

Scroll

21 to 43

Scroll

21 to 43

Outdoor unit

Piping connections

Indoor unit

Outdoor unit

FV54PEVL

R54PBETL

R54PBETL

FV54PEVL

VJ: 1 phase, 230V, 60Hz VL: 1 phase, 220V, 60Hz TL: 3 phase, 220V, 60Hz

48,800

14.3

5.80

18.0

8.41

1,850 x 580 x 390

54

34.0

55 / 52 / 48

1,250 x 1,030 x 412

114

61

5.50

ø19.1

ø12.7

30

20

5

Btu/h

kW

kW

A

Btu/hW

mm

kg

m3/min

dB(A)

mm

kg

dB(A)

kg

˚CDB

mm

mm

m

m

m

36,000

10.6

4.10

21.0

8.78

1,750 x 540 x 390

48

27.0

56 / 53 / 51

840 x 1,030 x 410

88

57

3.25

ø19.1

ø12.7

30

20

5

Gas

Liquid

FV36PEVJ

R36PBEVJ

FV36PEVJ

R36PBEVJ

Power supply

NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.

Cooling capacity

SPECIFICATIONS

10

Wall Mounted Type

Model name

Power consumption

Running current

EER

Power supply

Dimensions (H x W x D)

Machine weight

Airflow rate (H)

Sound level (H / M / L )

Factory charge

Gas

Liquid

Dimensions (H x W x D)

Machine weight

Sound level

Compressor type

Refrigerant charge (R-22)

Operation range

Piping connections

Max. piping length

Max. height difference

Chargeless

Outdoor unit

Indoor unit

Outdoor unit

FT30HEVJ

R30HEVJ

Indoor unit FT30HEVJ

R30HEVJ

1 phase, 230V, 60Hz

31,250

8.68

3.35

16.0

9.33

326 x 1,178 x 253

17.5

18.3

49 / 47 / 44

840 x 1,018 x 412

90

57

Rotary

2.50

18 to 43

ø15.9

ø9.5

30

15

7.5

kJ/h

kW

kW

A

kJ/hW

mm

kg

m3/min

dB(A)

mm

kg

dB(A)

kg

˚CDB

m

m

mm

mm

m

Cooling capacity

NoteCooling capacity is based on: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB; piping length 5m.

All rights reservedPrinted in Japan 02/11/002 AKc

DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Specifications, designs and other content appearing in this brochure are current as of February 2011 but subject to change without notice.