Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
TENANCY 2 FOODOUTLET
TENANCY 1SERVICE STATION
SERVICES
FUEL DISPENSING FORECOURT
ENTRY ENTRY
D/THRU ENTRYD/THRU
EXIT
MIDD
LE R
OAD
CREST ROAD
PROPOSED ENTRY/EXIT (LEFT IN / LEFT OUT ONLY)
PROPOSED ENTRY/EXIT
NEIGHBOURING SITE
NEIGHBOURING SITE
SERVICES
5400
9060
1956
054
0042
00
D/THRU ORDER POINT
FUEL VENTS
1500
D/THRU PAY POINT
D/THRU PAY POINT
AIR / WATER
1 7 8 11
12 26
SITE
BOU
NDAR
Y
SITE
BOU
NDAR
Y
REFUSE ENCLOSURE
PYLON SIGNAGE
BIORETENTION
DRIVE
THRU
QUE
UEING
FUEL FILL POINTS
4500 7200 7200 10000 45004955
13225
U/GROUND FUEL STORAGE TANKS
1000
029
160
18200
3190
2020
6875
5400
2595
10115
TYP
2600
13875
PYLON SIGNAGE
NEW 1500 WIDE FOOTPATH
NEW ENTRY FOOTPATH
SPEED HUMP
SPEED HUMP
PAINTED CHEVRON LINEMARKING
ACOUSTIC/AWNING STRUCTURE TO FULL EXTENT OF CAR PARKING BAYS. REFER ACOUSTIC REPORT
DELIVERY/REFUSE COLLECTION BAY
LINE OF CANOPY OVER
LINE OF CANOPY OVER
1062
5
4150 650 3200 1500 7200 1500
3200
ACOU
STIC B
ARRIER
ACOUSTIC BARRIER
ACOUSTIC BARRIER TO D/THRU. REFER ACOUSTIC REPORT
PAINTED CHEVRON LINEMARKING
RPD LOT 1 ON SP107492PARISH OF MITCHELLCOUNTY OF STANLEY
LOT AREA - 4,238m²
DEVELOPMENT ASSESSMENT
• TENANCY 1 - SERVICE STATION - 228m²• TENANCY 2 - FOOD & DRINK OUTLET - 162m²
• TOTAL CAR PARKING - 26• CAR REFUELLING POSITIONS - 8• D/THRU QUEUE CAPACITY - 12
BUILDING AREAS - GFA
• CAR DISPENSING FORECOURT - 325m²(UNENCLOSED BUILDING FOOTPRINT)
• REFUSE & SHARED SERVICES - 80m²
MISCELANEOUS STRUCTURES
CAR PARKING
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
Job Number - Drawing Number Revision
i m a g i n e
BUILDING DESIGNERS LICENCE No. 1002212OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011
PH. (07) 3857 0942E: [email protected]
CONSULTING ENGINEER
THIS DRAWING IS NOTDA ISSUE
FOR CONSTRUCTION
Scale @A1
Drawn
Date
Approved By
ALL SCHEDULES SHOULD BE CHECKED WITH THE REMAINDER OF THE DRAWING SET.SCHEDULED RATES AND AREAS ARE INTENDED FOR ASSISTANCE ONLY. NO RESPONSIBILITY IS TAKEN FOR THE ACCURACY OF QUANTITIES.ANY DISCREPANCIES IN SCHEDULES SHOULD BE IDENTIFIED TO THE AUTHOR NOTED.ALL AREAS ARE GROSS AREAS, UNLESS NOTED OTHERWISE
VERVE SCHEDULES DISCLAIMER:1.
2.
3.
4. c r e a t e d e l i v e r DAs indicated
DA01
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
PROPOSED SITE PLAN
16102JG
APR - 2017
GN
TRAFFIC SIGNAGE.GIVE WAY &
NO RIGHT TURN.
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIANFOOTPATHS, COVERED & RELOCATED CARPARKING, FULLSITE SHOWN, ACOUSTIC PANELS AND FENCING PERACOUSTIC REPORT
C 04.08.2017 CWS RESPONSE TO COUNCIL IR
D 18.10.2017 CWS RESPONSE TO COUNCIL IR
TENANCY 2 FOOD
OUTLET
TENANCY 1
SERVICE STATION
SERVICES
REFUSE
ENCLOSURE
FUEL DISPENSING FORECOURT
LINE OF CANOPY OVER
LINE OF CANOPY OVER
LINE OF AWNING OVER
LINE OF AWNING OVERLINE OF AWNING OVER
LINE OF AWNING OVER
OFFICE STORE
PWD
DRIVE THRU
PICKUP POINT
DRIVE THRU
PAY POINT
DRIVE THRU
ORDER POINT
PYLON SIGN
PYLON SIGN
13570 21500 4325 13875
1405
054
00
AMB
CLR
COLD ROOMFRZSTORE
CONSOLE
SITE BOUNDARY
SITE
BOU
NDARY
SITE
BOUNDARY
VARIED HEIGHT ACOUSTIC
BARRIER PANELLING
VARIED HEIGHT ACOUSTIC
BARRIER PANELLING
CLEAR PERSPEX PANELS TO
D/THRU ACOUSTIC BARRIER
CLEAR PERSPEX PANELS TO
D/THRU ACOUSTIC BARRIER
SPEED HUMP
SPEED HUMP
ACO
USTIC B
ARRIER
AIR/
WATER
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
Job Number - Drawing Number Revision
i m a g i n e
BUILDING DESIGNERS LICENCE No. 1002212OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011
PH. (07) 3857 0942E: [email protected]
CONSULTING ENGINEER
THIS DRAWING IS NOTDA ISSUE
FOR CONSTRUCTION
Scale @A1
Drawn
Date
Approved By
ALL SCHEDULES SHOULD BE CHECKED WITH THE REMAINDER OF THE DRAWING
SET.
SCHEDULED RATES AND AREAS ARE INTENDED FOR ASSISTANCE ONLY. NO
RESPONSIBILITY IS TAKEN FOR THE ACCURACY OF QUANTITIES.
ANY DISCREPANCIES IN SCHEDULES SHOULD BE IDENTIFIED TO THE AUTHOR
NOTED.
ALL AREAS ARE GROSS AREAS, UNLESS NOTED OTHERWISE
VERVE SCHEDULES DISCLAIMER:
1.
2.
3.
4. c r e a t e d e l i v e r C 1 : 100
DA02
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
PROP. FLOOR PLAN
16102JG
APR - 2017
GN
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 04.08.2017 CWS RESPONSE TO COUNCIL IR
C 18.10.2017 CWS RESPONSE TO COUNCIL IR
SERVICE STATION TENANCY TENANCY 2
DRIVE THRU
HORIZONTAL TIMBER LOOK CLADDING SIGNAGE BLADE BEYOND
LOUVRE SCREENINGENTRYSHOP ENTRY
CONCRETE PANEL EXTERNAL WALLS -
TO FUEL RETAILERS STANDARDSPORTAL TREATMENT & SIGNAGE TO
FUEL RETAILER'S SPECIFICATIONS
CREST STREET
ENTRY / EXIT
ALUM. FRAMED ENERGY EFFICIENT
SHOPFRONT GLAZING SYSTEM
LOW LEVEL
LANDSCAPING
SIGNAGE TO TENANT
SPECIFICATIONS
POWDERCOAT ALUMINIUM
BATTEN TO REFUSE ENCLOSURE
SITE
BOU
NDARY
4560
3300
DELIVERY/ REFUSE
COLLECTION BAY
SIGNAGE TO TENANT
SPECIFICATIONS
2.0m(H) ACOUSTIC FENCE
SERVICE STATION TENANCY FOOD & DRINK OUTLET
PYLON SIGNAGE
FUEL FORECOURT CANOPY BEYONDILLUMINATED SIGNAGE TO BUILDING BLADE. NOT
PART OF THIS APPLICATION
EXPRESSED JOINT EXTERNAL CLADDING. FINAL
FINISH TO FOOD RETAILER'S STANDARDS
TEXTURE/PAINT FINISH TO
ACOUSTIC BARRIER PANELLING
D/THRU ORDER POINT
SITE PYLON SIGN
ORDER PICKUP
BEYOND
CLEAR PERSPEX PANELS TO
D/THRU ACOUSTIC BARRIER
POWDERCOAT ALUMINIUM BATTEN
SCREENING TO REFUSE ENCLOSURE
FOOD & DRINK OUTLET SERVICE STATION TENANCY
MIDDLE ROADACCESS DRIVEWAY
FROM CREST ROAD
SITE
BOU
NDARY
VARIED HEIGHTS TO
ACOUSTIC SCREENING.
D/THRU PAY POINT
Top of Canopy6.45
Canopy Soffit5.45
FUEL DISPENSING FORECOURTFUEL SALES BUILDING
CREST STREET
ENTRY / EXIT
FUEL FORECOURT CANOPY TO
FUEL RETAILER'S STANDARDS
MIDDLE ROAD
ENTRY / EXIT
LOW LEVEL PLANTING
AWNING TO DRIVE THRU MENUBOARD ORDER POINT
CONCRETE PANEL EXTERNAL WALLS. PAINT
FINISH TO FUEL RETAILERS STANDARDS
REFUSE ENCLOSURE
SIGNAGE BLADE BEYOND
LINE OF SIGNAGE PYLON BEYOND
4560 5060
1000
5450
SITE PYLON SIGN
SITE
BOU
NDARY
TEXTURE/PAINT FINISH TO VARIED
HEIGHT ACOUSTIC BARRIER PANELLING
POWDERCOAT ALUMINIUM BATTEN
SCREENING TO REFUSE ENCLOSURE
Top of Canopy6.45
Canopy Soffit5.45
1000
5450
FUEL DISPENSING FORECOURT FUEL SALES BUILDING
FUEL FORECOURT CANOPY TO
FUEL RETAILER'S STANDARDS
LOW LEVEL PLANTING
CONCRETE PANEL EXTERNAL WALLS.
PAINT FINISH TO FUEL RETAILERS STANDARDS
SIGNAGE BLADE
6500
SIGNAGE PYLON SIGN EXPRESSED JOINT EXTERNAL CLADDING. PAINT
FINISH TO FOOD RETAILERS STANDARDS.
SITE
BOU
NDARY
HORIZONTAL TIMBER LOOK CLADDING.
TEXTURE/PAINT FINISH TO VARIED HEIGHT ACOUSTIC BARRIER PANELLING
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
Job Number - Drawing Number Revision
i m a g i n e
BUILDING DESIGNERS LICENCE No. 1002212OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011
PH. (07) 3857 0942E: [email protected]
CONSULTING ENGINEER
THIS DRAWING IS NOTDA ISSUE
FOR CONSTRUCTION
Scale @A1
Drawn
Date
Approved Byc r e a t e d e l i v e r C
1 : 100
DA03
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
BUILDING ELEVATIONS &
PERSPECTIVES
16102JG
APR - 2017
GN
1 : 100
1 NORTH ELEVATION
1 : 100
2 SOUTH ELEVATION
1 : 100
3 EAST ELEVATION
1 : 100
4 WEST ELEVATION
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIAN
FOOTPATHS, COVERED & RELOCATED CARPARKING, FULL
SITE SHOWN, ACOUSTIC PANELS AND FENCING PER
ACOUSTIC REPORT
C 04.08.2017 CWS RESPONSE TO COUNCIL IR
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
Job Number - Drawing Number Revision
i m a g i n e
BUILDING DESIGNERS LICENCE No. 1002212OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011
PH. (07) 3857 0942E: [email protected]
CONSULTING ENGINEER
THIS DRAWING IS NOTDA ISSUE
FOR CONSTRUCTION
Scale @A1
Drawn
Date
Approved By
ALL SCHEDULES SHOULD BE CHECKED WITH THE REMAINDER OF THE DRAWING
SET.
SCHEDULED RATES AND AREAS ARE INTENDED FOR ASSISTANCE ONLY. NO
RESPONSIBILITY IS TAKEN FOR THE ACCURACY OF QUANTITIES.
ANY DISCREPANCIES IN SCHEDULES SHOULD BE IDENTIFIED TO THE AUTHOR
NOTED.
ALL AREAS ARE GROSS AREAS, UNLESS NOTED OTHERWISE
VERVE SCHEDULES DISCLAIMER:
1.
2.
3.
4. c r e a t e d e l i v e r CDA06
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
BUILDING ELEVATIONS &
PERSPECTIVES
16102JG
APR - 2017
GN
1 PERSPECTIVE 5
2 PERSPECTIVE 6
FUEL SALES BUILDINGFUEL DISPENSING FORECOURTCONCRETE PANEL EXTERNAL WALLS.
PAINT FINISH TO FUEL RETAILERS STANDARDS
ENTRY / EXIT TO CREST ST
HORIZONTAL TIMBER LOOK CLADDING
ILLUMINATED SIGNAGE TO BUILDING BLADE.
NOT PART OF THIS APPLICATION
PYLON SIGNAGE
LOW LEVEL PLANTING
POWDERCOAT ALUMINIUM BATTEN
SCREENING TO REFUSE ENCLOSURE
ACCESS GATE TO MECHANICAL
PLANT SERVICE AREA
EXPRESS JOINT EXTERNAL CLADDING. PAINT
FINISH TO FOOD RETAILER'S STANDARDS
ORDER PICKUP POINT ORDER PAY POINT
PYLON SIGNAGE
LOW LEVEL PLANTING
SIGNAGE BLADE BEYOND
TEXTURE/ PAINT FINISH TO
SERVICE ENCLOSURE PANELLING
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIAN
FOOTPATHS, COVERED & RELOCATED CARPARKING, FULL
SITE SHOWN, ACOUSTIC PANELS AND FENCING PER
ACOUSTIC REPORT
C 04.08.2017 CWS RESPONSE TO COUNCIL IR
2.0m(H) ACOUSTIC FENCE
PEDESTRIAN FOOTPATH
AWNING OVER CARPARKING
2.0m(H) ACOUSTIC FENCE BEYOND
AWNING OVER CARPARKING
TEXTURE/PAINT FINISH TO VARIED
HEIGHT ACOUSTIC BARRIER PANELLING
TEXTURE/PAINT FINISH TO VARIED
HEIGHT ACOUSTIC BARRIER PANELLING
CLEAR PERSPEX PANELS TO D/THRU
ACOUSTIC BARRIER
CLEAR PERSPEX PANELS TO
D/THRU ACOUSTIC BARRIER
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
Job Number - Drawing Number Revision
i m a g i n e
BUILDING DESIGNERS LICENCE No. 1002212OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011
PH. (07) 3857 0942E: [email protected]
CONSULTING ENGINEER
THIS DRAWING IS NOTDA ISSUE
FOR CONSTRUCTION
Scale @A1
Drawn
Date
Approved Byc r e a t e d e l i v e r CDA04
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
BUILDING ELEVATIONS &
PERSPECTIVES
16102JG
APR - 2017
GN
1 PERSPECTIVE 1
FUEL DISPENSING FORECOURT
TENANCY 2
FUEL SALES BUILDING
FUEL FORECOURT CANOPY TO
FUEL RETAILERS STANDARDS
CONCRETE PANEL EXTERNAL WALLS. PAINT
FINISH TO FUEL RETAILERS STANDARDS
HORIZONTAL TIMBER LOOK CLADDING
SIGNAGE BLADE
PORTAL TREATMENT TO FUEL
RETAILERS STANDARDS
PYLON SIGNAGE
LOW LEVEL PLANTING
CARPARKING
2 PERSPECTIVE 2
FUEL DISPENSING FORECOURT
LOW LEVEL PLANTING
FUEL FORECOURT CANOPY TO
FUEL RETAILERS STANDARDS
ENTRY / EXIT TO CREST ST
FUEL SALES BUILDING
PORTAL TREATMENT TO FUEL
RETAILERS STANDARDS
CARPARKING
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIAN
FOOTPATHS, COVERED & RELOCATED CARPARKING, FULL
SITE SHOWN, ACOUSTIC PANELS AND FENCING PER
ACOUSTIC REPORT
C 04.08.2017 CWS RESPONSE TO COUNCIL IR
2.0m(H) ACOUSTIC FENCE
2.0m(H) ACOUSTIC FENCE
POWDERCOAT ALUMINIUM BATTEN
SCREENING TO REFUSE ENCLOSURE
Revision and approvals
This drawing is the c copyright & property of VERVE BUILDING DESIGN and must not be used or duplicated without authorisation.
Do not scale this drawing.
Check all dimensions on site prior commencement of works
c 2011 copyright, all rights reserved.
f a s t f o o d r e s t a u r a n t d e s i g n
t r a v e l c e n t r e / s e r v i c e s t a t i o ns
p r o j e c t c o n c e p t t o c o m p l e t i o n
c o m m e r c i a l / i n d u s t r i a l / r e t a i lProject Description Drawing Title
Job Number - Drawing Number Revision
i m a g i n e
BUILDING DESIGNERS LICENCE No. 1002212OFFICE 1, LEVEL 1, 318 JUNCTION RD, CLAYFIELD 4011
PH. (07) 3857 0942E: [email protected]
CONSULTING ENGINEER
THIS DRAWING IS NOTDA ISSUE
FOR CONSTRUCTION
Scale @A1
Drawn
Date
Approved Byc r e a t e d e l i v e r CDA05
PROPOSED MIXED USE DEVELOPMENT
356 MIDDLE ROAD, GREENBANK
BUILDING ELEVATIONS &
PERSPECTIVES
16102JG
APR - 2017
GN
2 PERSPECTIVE 4
FUEL SALES BUILDING
FUEL FORECOURT CANOPY TO
FUEL RETAILERS STANDARDS
CONCRETE PANEL EXTERNAL WALLS.
PAINT FINISH TO FUEL RETAILERS STANDARDS
HORIZONTAL TIMBER
LOOK CLADDING
PORTAL TREATMENT TO FUEL
RETAILERS STANDARDS
ORDER STATION
DRIVE THRU EXIT
AWNING TO DRIVE
THRU PICK UP WINDOW
CARPARKINGALUM. ENERGY EFFICIENT
SHOPFRONT GLAZING SYSTEM
FUEL SALES BUILDING
CONCRETE PANEL EXTERNAL
WALLS. PAINT FINISH TO FOOD
RETAILERS STANDARDS
1 PERSPECTIVE 3
TENANCY 2
SIGNAGE TO TENANT
SPECIFICATIONS
ILLUMINATED SIGNAGE TO BUILDING
BLADE. NOT PART OF THIS APPLICATION
SCREENING & LOW LEVEL PLANTINGCLEAR PERSPEX PANELS TO D/THRU
ACOUSTIC BARRIER
Rev Date Drn Description Appr
A 19.05.17 JG ISSUE FOR D.A.
B 31.07.2017 CWS REVISED ISSUE FOR D.A. - NEW PEDESTRIAN
FOOTPATHS, COVERED & RELOCATED CARPARKING, FULL
SITE SHOWN, ACOUSTIC PANELS AND FENCING PER
ACOUSTIC REPORT
C 04.08.2017 CWS RESPONSE TO COUNCIL IR
2.0m(H) ACOUSTIC FENCE
TEXTURE/PAINT FINISH TO VARIED
HEIGHT ACOUSTIC BARRIER PANELLING
2.0m(H) ACOUSTIC FENCE
DRIVE THRU PAY POINT