Upload
others
View
8
Download
0
Embed Size (px)
Citation preview
Data sheet
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 1© Danfoss | DCS (MWA) | 2017.10
Spare parts and accessories Solenoid valves, types EVRA, EVRAT, EVRS and EVRST Pilot valves, types EVM (NC) and EVM (NO)
Valve type Size See details on page # Code no.
Inspection kitsEVRA 25 2 032F2326
EVRA 32/40 3 032F2327
Repair kitsEVRA / EVRS 3 4 032F2329
EVRA / EVRS 10 5 032F2330
EVRA / EVRS 15 6 032F2331
EVRA / EVRS 20 7 032F2332
EVRA / EVRS 25 8 032F2333
EVRA / EVRS 32 9 032F2334
EVRA / EVRS 40 10 032F2335
EVRAT / EVRST 10 11 032F2343
EVRAT / EVRST 15 12 032F2344
EVRAT / EVRST 20 13 032F2345
EVM NC 14 032F2324
EVM NO 15 032F2325
Overhaul kits (Previous valve design)EVRA 10 16 032F2202
EVRA 15 17 032F2209
EVRA 20 18 032F2210
EVRA 25 19 032F2218
EVRAT 10 20 032F2321
EVRAT 15 21 032F2322
EVRAT 20 22 032F2323
Valve type Size See details on page # Code no.
Overhaul kits (Current valve design)EVRA / EVRS 3 23 032F2336
EVRA / EVRS 10 24 032F2337
EVRA / EVRS 15 25 032F2338
EVRA / EVRS 20 26 032F2339
EVRA / EVRS 25 27 032F2340
EVRA / EVRS 32 28 032F2341
EVRA / EVRS 40 29 032F2342
EVRAT / EVRST 10 30 032F2346
EVRAT / EVRST 15 31 032F2347
EVRAT / EVRST 20 32 032F2348
EVRA/EVRAT EVRS/EVRST EVM (NC/NO)
Inspection kits:Contain all gaskets, O-rings and aluminium rings belonging to 1 valve size.For detailed content, see specific pages mentioned above.
Repair kits:Contain all gaskets, O-rings and aluminium rings belonging to 1 valve size, armature, diaphram, piston and piston ring.For detailed content, see specific pages mentioned above.
Overhaul kits:Contain all gaskets, O-rings and aluminium rings belonging to 1 valve size and parts that could be damaged or worn out.For detailed content, see specific pages mentioned above.
* Also applicable for AKVA 20
*
Inspection kit | Code number 032F2326Solenoid valve, type EVRA, size 25
1 2 3 4 6
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
5= Rubber
Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
” Ø10
mm
Ø0.40
” Ø6.07
mm
Ø0.25
ӯ6
6 mm
Ø2.60
”
Ø39 m
m
Ø1.53
”
= Alu. = Fibre= Alu.
7
Total no. = 1
Ø5.28
mm
Ø0.21
”
32F517_I_2_2012Danfoss
6
1
2
3
4
65
7
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 2© Danfoss | DCS (MWA) | 2017.10
Inspection kit | Code number 032F2327Solenoid valve, type EVRA, size 32/40
032F2327 can also be used for electric expansion valve, type AKVA 20
1
Total no. = 1 Total no. = 2 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
” Ø66
mm
Ø2.60
”
= Alu.= Alu.2 3 4 5
Total no. = 2 Total no. = 1
Ø42 m
m
Ø1.66
”
6
Total no. = 1
Ø4 mm
Ø0.2”
42H45_I_2014Danfoss
1
2
3
4
5
4
2
6
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 3© Danfoss | DCS (MWA) | 2017.10
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 4© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2329Solenoid valves, types EVRA and EVRS, size 3
1 2 3 4 6
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
5
Total no. = 1
Ø14 m
m
Ø0.56
”
= Alu.
Ø27 m
m
Ø1.04
”
= Fibre
Ø32 m
m
Ø1.26
”
Ø2.6 m
m
Ø0.10
”
= Alu.
Ø10 m
m
Ø0.4”
For AC / DC
42.5
mm
1.65
”
EVRS
32F6
89_R
_201
2D
anfo
ss
6
1
2
3
4
5
6
EVRA
1
2
3
5
4
32F4
17_R
_201
2D
anfo
ss
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 5© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2330Solenoid valves, types EVRA and EVRS, size 10
1 2 3 4
Total no. = 1 Total no. = 1 Total no. = 2
5= Alu.
Total no. = 1Ø0
.56”
= Fibre
Ø32 m
m
Ø1.26
”
6
Total no. = 1 Total no. = 1
Ø27 m
m
Ø1.04
” Ø31 m
m
Ø1.22
”
= Rubber
Ø49 m
m
Ø1.92
”
Ø14 m
m44.
9 m
m1.
71”
For AC / DC
32F362_R_2012Danfoss
4
6
1
3
2
56
EVRSEVRAA32F463_R_2012Danfoss
3
1
5
2
4
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 6© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2331Solenoid valves, types EVRA and EVRS, size 15
1 2 3 4
Total no. = 1 Total no. = 1 Total no. = 2
5= Alu.
Total no. = 1
Ø14 m
m
Ø0.56
”
= Fibre
Ø32 m
m
Ø1.26
”
6
Total no. = 1 Total no. = 1
Ø27 m
m
Ø1.04
” Ø31 m
m
Ø1.22
”
= Rubber
Ø49 m
m
Ø1.92
”44.9
mm
1.71
”
For AC / DC
32F516_R_2012Danfoss
4
6
1
3
2
5
6
EVRSEVRAA32F463_R_2012Danfoss
3
1
5
2
4
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 7© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2332EVRA and EVRS, size 20
EVRSEVRA32F516_R_2012Danfoss
4
6
1
3
2
5
6
A32F463_R_2012Danfoss
3
1
5
2
4
1 2 3 4
Total no. = 1 Total no. = 1 Total no. = 2
5= Alu.
Total no. = 1
Ø14 m
m
Ø0.56
”
= Fibre
Ø39 m
m
Ø1.54
”
6
Total no. = 1 Total no. = 1
Ø27 m
m
Ø1.04
” Ø38 m
m
Ø1.5”
= Rubber
Ø64 m
m
Ø2.52
”44.9
mm
1.71
”
For AC / DC
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 8© Danfoss | DCS (MWA) | 2017.10
1
Total no. = 1 Total no. = 1 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
”
= Alu.= Alu.2 3 4 5
Total no. = 1 Total no. = 1
Ø5 mm
Ø0.21
”
= Rubber
Ø66 m
m
Ø2.60
”
6 7 8 9 10
Total no. = 2 Total no. = 1 Total no. = 1 Total no. = 1Ø3
9 mm
Ø1.53
”
= Fibre
42.5
mm
1.67
”
Ø3.3 m
m
Ø0.13”
Ø44 mm
Ø1.73”
= Steel
Total no. = 1
32F517_R_2012Danfoss
6
1
2
3
4
6
5
7
8
9
10
Repair kit | Code number 032F2333Solenoid valve, type EVRA, size 25
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 9© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2334Solenoid valve, type EVRA, size 32
1
Total no. = 1 Total no. = 2 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
”
= Alu.= Alu.2 3 4 5
Total no. = 2 Total no. = 1
Ø66 m
m
Ø2.60
”
7 8 9 10
Total no. = 1 Total no. = 1 Total no. = 1
42.5
mm
1.67
”
Ø3.3 m
m
Ø0.13”
Ø44 mm
Ø1.73”
= Steel
Ø42 m
m
Ø1.66
”
11
Total no. = 1
Ø4 mm
Ø0.2”
Total no. = 1
42H45_R_2014Danfoss
1
2
3
4
5
4
2
7
8
109
11
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 10© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2335Solenoid valve, type EVRA, size 40
1
Total no. = 1 Total no. = 2 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
”
= Alu.= Alu.2 3 4 5
Total no. = 2 Total no. = 1
Ø66 m
m
Ø2.60
”
7 8 9 10
Total no. = 1 Total no. = 1 Total no. = 1
42.5
mm
1.67
”
Ø3.3 m
m
Ø0.13”
Ø44 mm
Ø1.73”
= Steel
Ø42 m
m
Ø1.66
”
11
Total no. = 1
Ø4 mm
Ø0.2”
Total no. = 1
42H45_R2_2014Danfoss
1
2
3
4
5
4
2
7
8
109
11
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 11© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F234335Solenoid valves, types EVRAT and EVRST, size 10
Ø14 m
m
Ø0.56
”
= Fibre
Ø32 m
m
Ø1.26
”
= Rubber
Ø49 m
m
Ø1.92
”
1
Total no. = 1
Ø31 mmØ1.22”
2
Total no. = 1
3
Total no. = 1
= Alu.
Ø27 m
m
Ø1.04
”
4
Total no. = 1
5
Total no. = 2
6
Ø5 mm
Ø0.2”
Total no. = 1
32F142_R_2014Danfoss
3
5
1
4
2
5
6
EVRSTEVRAT
1
3
2
4
A32F419_R_2014Danfoss
6
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 12© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2344Solenoid valves, types EVRAT and EVRST, size 15
Ø14 m
m
Ø0.56
”
= Fibre
Ø32 m
m
Ø1.26
”
= Rubber
Ø49 m
m
Ø1.92
”
1
Total no. = 1
2
Total no. = 1
3
Total no. = 1
= Alu.
Ø27 m
m
Ø1.04
”
4
Total no. = 1
5
Total no. = 2
Ø31 mmØ1.22”
6
Ø5 mm
Ø0.2”
Total no. = 1
32F508_R_2014Danfoss
3
5
1
4
2
5
6
EVRSTEVRAT
1
3
2
4
A32F419_R_2014Danfoss
6
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 13© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2345Solenoid valves, types EVRAT and EVRST, size 20
Ø14 m
m
Ø0.56
”
= Fibre
Ø39 m
m
Ø1.54
”
= Rubber
Ø64 m
m
Ø2.52
”
1
Total no. = 1
2
Total no. = 1
3
Total no. = 1
= Alu.
Ø27 m
m
Ø1.04
”
4
Total no. = 1
5
Total no. = 2
Ø38 mmØ1.5”
6
Ø5 mm
Ø0.2”
Total no. = 1
32F514_R_2014Danfoss
3
5
1
4
2
5
6
EVRSTEVRAT
1
3
2
4
A32F419_R_2014Danfoss
6
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 14© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2324Pilot valves, types EVM (NC)
1 2 3 4 6
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1
7
Total no. = 1
5
Total no. = 1
Ø14 m
m
Ø0.56
”
= Alu.
Ø27 m
m
Ø1.04
”
= Fibre
Ø33 m
m
Ø1.3”
Ø3.3 m
m
Ø0.13
”
= Alu.
Ø10 m
m
Ø0.4”
Ø9 mm
Ø0.35
”
42.4
5 m
m1.
71”
27B2
87_R
_201
2D
anfo
ss
2
1
3
6
4
5
7EVM NC
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 15© Danfoss | DCS (MWA) | 2017.10
Repair kit | Code number 032F2325Pilot valves, types EVM (NO)
1 2 3 4 6
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
7
Total no. = 1
5
Total no. = 1
Ø14 m
m
Ø0.56
”
= Alu.
Ø27 m
m
Ø1.04
”
= Fibre
Ø33 m
m
Ø1.3”
Ø1.8 m
m
Ø0.07
”
= Alu.
Ø10 m
m
Ø0.4”
Ø9 mm
Ø0.35
”
A27
B288
_R_2
012
Dan
foss
2
1
3
6
4
5
7EVM NO
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 16© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2202Solenoide valve, type EVRA, size 10 (previous design)
1 2 3 4 6
9 11
Total no. = 1
For AC/DC
Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2
12
Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
44.9
mm
1.71
”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø24 m
m
Ø0.94
”
= Rubber
Ø41 m
m
Ø1.6”
= Fibre
Ø32 m
m
Ø1.26
”
73 m
m2.
87"
Total no. = 1Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
32F361_O_2011Danfoss
6
5
7
10
12
11
4
2
9
1
8
9
3
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 17© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2209Solenoide valve, type EVRA, size 15 (previous design)
1 2 3 4 6
9 11
Total no. = 1
For AC/DC
Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2
12
Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
44.9
mm
1.71
”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø31 m
m
Ø1.22
”
= Rubber
Ø49 m
m
Ø1.93
”
= Fibre
Ø32 m
m
Ø1.26
”
73 m
m2.
87"
Total no. = 1Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
32F378_O_2011Danfoss
7
11
9
10
12
1
2
4
5
6
8
9
3
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 18© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2210Solenoide valve, type EVRA, size 20 (previous design)
1 2 3 4 6
9 11
Total no. = 1
For AC/DC
Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2
12
Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
44.9
mm
1.71
”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø38 m
m
Ø1.5”
= Rubber
Ø64 m
m
Ø2.52
”
= Fibre
Ø39 m
m
Ø1.53
”
73 m
m2.
87"
Total no. = 1Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
32F378_O_2011Danfoss
7
11
9
10
12
1
2
4
5
6
8
9
3
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 19© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2218Solenoide valve, type EVRA, size 25 (previous design)
1 2 3 4 6
9 11
Total no. = 1
For AC/DC
Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2
13
Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø2.6 m
m
Ø0.1”
Ø75 mm
Ø2.94”
= Fibre
Ø39 m
m
Ø1.53
”
Total no. = 1Total no. = 1
NV32
mm
NV
1.26
”
35 m
m1.
39”
= Fibre
67 m
m2.
64"
32F364_O_2011Danfoss
6
5
8
10
11
4
2
1
13
99
3
7
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 20© Danfoss | DCS (MWA) | 2017.10
1 2 3 4 6
9 11
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2
12
Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
35 m
m1.
38”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø24 m
m
Ø0.94
”
= Rubber
Ø41 m
m
Ø1.6”
= Fibre
Ø32 m
m
Ø1.26
”
73 m
m2.
87"
Total no. = 1Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
32F143_O_2011Danfoss
6
5
7
10
12
11
4
2
1
8
99
3
Overhaul kit | Code number 032F2321Solenoide valve, type EVRAT, size 10 (previous design)
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 21© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2322Solenoide valve, type EVRAT, size 15 (previous design)
1 2 3 4 6
9 11
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2
12
Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
35 m
m1.
38”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø31 m
m
Ø1.22
”
= Rubber
Ø49 m
m
Ø1.93
”
= Fibre
Ø32 m
m
Ø1.26
”
73 m
m2.
87"
Total no. = 1Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
32F376_O_2011Danfoss
3
7
11
9
10
12
1
2
4
5
6
8
9
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 22© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2323Solenoide valve, type EVRAT, size 20 (previous design)
1 2 3 4 6
9 11
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 4 Total no. = 4
Total no. = 2 Total no. = 1
10
Total no. = 1
87
Total no. = 1
5= Rubber
Total no. = 1
51 m
m2.
01”
35 m
m1.
38”
Ø14 m
m
Ø0.56
”
6 m
m0.
24"
Ø22 m
m
Ø0.87
” 20
mm
0.79
"
Ø38 m
m
Ø1.5”
= Rubber
Ø64 m
m
Ø2.52
”
= Fibre
Ø39 m
m
Ø1.53
”
70.5
mm
2.78
"
Total no. = 1
NV32
mm
NV
1.26
”
Total no. = 1
12
Ø5 mm
Ø0.2”Ø
5 mm
7
1
2
45
6
8
3
11
9
10
32F385_O10_2014Danfoss
9
12
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 23© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2336Solenoide valves, types EVRA and EVRS, size 3
7
Total no. = 1
1 2 3 4 6
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
5
Total no. = 1
Ø14 m
m
Ø0.56
”
= Alu.
Ø27 m
m
Ø1.04
”
= Fibre
Ø32 m
m
Ø1.26
”
Ø2.6 m
m
Ø0.10
”
= Alu.
Ø10 m
m
Ø0.4”
8
Total no. = 1
51 m
m2.
01”
42.5
mm
1.71
”
For AC / DC
EVRS
32F6
89_O
_201
2D
anfo
ss1
2
3
4
5
6
8
6
7
EVRA
1
2
3
5
4
32F4
17_O
_201
2D
anfo
ss
6
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 24© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2337Solenoide valves, types EVRA and EVRS, size 10
1 2 3 4 6
9 11
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
Total no. = 1 Total no. = 1
10
Total no. = 4
87
Total no. = 1
5= Rubber
Total no. = 1
Ø14 m
m
Ø0.56
”
20 m
m
0.79
"
73 m
m2.
87"
Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
= Alu.
Ø27 m
m
Ø1.04
” Ø31 m
m
Ø1.22
”
Ø49 m
m
Ø1.92
”
= Fibre
Ø32 m
m
Ø1.26
”
51 m
m2.
01”
44.9
mm
1.71
”
For AC / DC
32F362_O_2012Danfoss
4
7
6
9
10
1
8 3
11
2
56
EVRSEVRA
A32F463_O_2012Danfoss
3
1
5
2
4
11
7
8
10
9
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 25© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2338Solenoide valves, types EVRA and EVRS, size 15
1 2 3 4 6
9 11
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
Total no. = 1 Total no. = 1
10
Total no. = 4
87
Total no. = 1
5= Rubber
Total no. = 1
Ø14 m
m
Ø0.56
”
20 m
m
0.79
"
73 m
m2.
87"
Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
= Alu.
Ø27 m
m
Ø1.04
” Ø31 m
m
Ø1.22
”
Ø49 m
m
Ø1.92
”
= Fibre
Ø32 m
m
Ø1.26
”
51 m
m2.
01”
44.9
mm
1.71
”
For AC / DC
32F516_O_2012Danfoss
4
7
6
9
10
1
8
3
11
2
5
6
EVRSEVRA
A32F463_O_2012Danfoss
3
1
5
2
4
11
7
8
10
9
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 26© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2339Solenoide valves, types EVRA and EVRS, size 20
1 2 3 4 6
9 11
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 2
Total no. = 1 Total no. = 1
10
Total no. = 4
87
Total no. = 1
5= Rubber
Total no. = 1
Ø14 m
m
Ø0.56
”
25 m
m
0.98
"
73 m
m2.
87"
Total no. = 1
NV32
mm
NV
1.26
”
Ø5 mm
Ø0.2”
= Alu.
Ø27 m
m
Ø1.04
” Ø38 m
m
Ø1.5”
Ø64 m
m
Ø2.52
”
= Fibre
Ø39 m
m
Ø1.54
”
51 m
m2.
01”
44.9
mm
1.71
”
For AC / DC
32F516_O_2012Danfoss
4
7
6
9
10
1
8
3
11
2
5
6
EVRSEVRA
A32F463_O_2012Danfoss
3
1
5
2
4
11
7
8
10
9
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 27© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2340Solenoide valve, type EVRA, size 25
1
Total no. = 1 Total no. = 1 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
”
= Alu.= Alu.2 3 4 5
Total no. = 1 Total no. = 1
6 7 8 10
Total no. = 2 Total no. = 1 Total no. = 1
42.5
mm
1.67
”
Ø3.3 m
m
Ø0.13” Ø
44 mm
Ø1.73”
= Steel9
11 12 13 1514
Total no. = 1
Ø5 mm
Ø0.21
”
Ø66 mm
Ø2.60”
= Rubber
Ø39 m
m
Ø1.53
”
= Fibre
Ø38 mm
Ø1.48”
Ø17 m
m
Ø0.67
Total no. = 1Total no. = 1 Total no. = 1
51 m
m2.
01”
70 m
m
2.74
”
Total no. = 1
NV 3
2 m
mNV
1.2
6”
Total no. = 1
Total no. = 1
32F517_O_2012Danfoss
6
1
2
3
4
6
5
7
89
10
11
13
12
14
15
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 28© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2341EVRA, size 32
1
Total no. = 1 Total no. = 2 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
”
= Alu.= Alu.2 3 4 5
Total no. = 2 Total no. = 1
7 8 10
Total no. = 1 Total no. = 1
42.5
mm
1.67
”
Ø3.3 m
m
Ø0.13” Ø
44 mm
Ø1.73”
= Steel9 11
12 13
Total no. = 1
Ø38 mm
Ø1.48”
Ø17 m
m
Ø0.67
Total no. = 1
Total no. = 1
Total no. = 1
51 m
m2.
01”
Ø66 m
m
Ø2.61
”
Ø42 m
m
Ø1.66
”
14
Total no. = 1
Ø4 mm
Ø0.2”
15
Total no. = 1
Total no. = 1
42H45_O_2014Danfoss
1
2
3
4
5
4
2
7
8
119 1012
13
1415
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 29© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2342Solenoide valve, type EVRA, size 40
1
Total no. = 1 Total no. = 2 Total no. = 1
Ø14 m
m
Ø0.56
” Ø27 m
m
Ø1.04
ӯ1
0 mm
Ø0.40
”
= Alu.= Alu.2 3 4 5
Total no. = 2 Total no. = 1
7 8 10
Total no. = 1 Total no. = 1
42.5
mm
1.67
”
Ø3.3 m
m
Ø0.13” Ø
44 mm
Ø1.73”
= Steel9 11
12 13
Total no. = 1
Ø38 mm
Ø1.48”
Ø17 m
m
Ø0.67
Total no. = 1
Total no. = 1
Total no. = 1
51 m
m2.
01”
Ø66 m
m
Ø2.61
”
Ø42 m
m
Ø1.66
”
14
Total no. = 1
Ø4 mm
Ø0.2”
15
Total no. = 1
Total no. = 1
42H45_O_2014Danfoss
1
2
3
4
5
4
2
7
8
119 1012
13
1415
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 30© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2346Solenoide valves, types EVRAT and EVRST, size 10
EVRAT EVRST
1 2 3 6
9
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1
Total no. = 1 Total no. = 1
10
Total no. = 1
87
Total no. = 4
4
Total no. = 1
Ø14 m
m
Ø0.56
”
20 m
m
0.79
"
= Rubber
Ø49 m
m
Ø1.92
”
Ø5 mm
Ø0.2”
= Alu.
Ø27 m
m
Ø1.04
”
51 m
m2.
01"
Ø31mmØ1.22"
5
Total no. = 2
= Fibre
Ø32 m
m
Ø1.26
”
73m
m2.
87"
NV 3
2 m
m
Ø5 mm
NV 1
.26”
A32F419_O_2012Danfoss
1
3
2
4
10
6
7
9
8
32F142_O_2012Danfoss
3
5
10
1
4
2
5
6
7
9
8
Data sheet | Spare parts and accessories for EVRA, EVRAT, EVRS, EVRST and EVM
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 31© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2347Solenoide valves, types EVRAT and EVRST, size 15
1 2 3 6
9
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1
Total no. = 1 Total no. = 1
10
Total no. = 1
87
Total no. = 4
4
Total no. = 1
Ø14 m
m
Ø0.56
”
20 m
m
0.79
"
= Rubber
Ø49 m
m
Ø1.92
”
Ø5 mm
Ø0.2”
= Alu.
Ø27 m
m
Ø1.04
”
51 m
m2.
01"
Ø31mmØ1.22"
5
Total no. = 2
= Fibre
Ø32 m
m
Ø1.26
”
73m
m2.
87"
NV 3
2 m
m
Ø5 mm
NV 1
.26”
32F508_O_2012Danfoss
3
5
1
4
2
5
10
6
7
9
8
A32F419_O_2012Danfoss
1
3
2
4
10
6
7
9
8
EVRAT EVRST
DKRCI.PY.BM0.C9.02 → DKRCI.PY.BM0.D1.02 | 520H6840 | 32© Danfoss | DCS (MWA) | 2017.10
Overhaul kit | Code number 032F2348Solenoide valves, types EVRAT and EVRST, size 20
1 2 3 6
9
Total no. = 1 Total no. = 1 Total no. = 1 Total no. = 1
Total no. = 1 Total no. = 1
10
Total no. = 1
87
Total no. = 4
4
Total no. = 1
Ø14 m
m
Ø0.56
”
25 m
m
0.98
"
= Rubber
Ø64 m
m
Ø2.52
”
Ø5 mm
Ø0.2”
= Alu.
Ø27 m
m
Ø1.04
”
51 m
m2.
01"
Ø31mmØ1.22"
5
Total no. = 2
= Fibre
Ø39 m
m
Ø1.54
”
NV 3
2 m
m
Ø5 mm
NV 1
.26”70
.5 m
m2.
78"
3
1
4
2
5
6
7
5
32F514_O10_2014Danfoss
10
9
8
1
3
2
4
6
7
A32F419_O10_2014Danfoss
10
9
8
EVRAT EVRST