DESIGN AND IMPLEMENTATION OF THE DIGITAL CONTROLLER FOR A FUEL CELL DC-DC POWER CONVERTER SYSTEM

O.A. AHMED, J.A.M. BLEIJS

Page 2: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

presentation Outline

IntroductionDynamic Performance of PEMFCFC Converter FeaturesController DesignSimulation ResultsControl Algorithm ImplementationConverter System ImplementationConclusions

2

Page 3: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Introduction

Back-up diesel generator PV system Wind Turbine

H2

Battery - +

Battery or Ultra-capacitor

DC =

AC ~ Critical

AC load

Single or three-phase AC load

DC =

DC =

AC =

DC =

AC ~

DC = AC

link

bus

DC ~

DC =

AC =

DC =

Fuel Cell system

DC =

DC =

DC link bus, voltage between 600V ~800V

DC Microgrid Power System

3

Page 4: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Introduction

DC Microgrid may comprise of :A dispatchable power generator, such as the fuel cell (FC) or a back-up diesel generator.Non-dispatchable sources, such as solar PV and wind turbines. Energy storage, such as ultra-capacitor or battery.The overall efficiency of the distributed system depends on efficiency of power electronic converters. To obtain a cost-effective converter solution:High efficiency.Low cost.Robust control system

4

Page 5: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

objective

Development of a Two-Loop Controller for

a High Efficiency

FBCFC for a FC generator

Dynamic Response

Analysis and Modeling of a Ballard Nexa 1.2kW PEMFC

Digital Controller

Design Based on a

TMS320F2812 DSP

5

Page 6: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Dynamic Performance of PEMFC

Experimental Dynamic Response Set-up for

PEMFC

Nexa data acquisition system is inadequate to show actual response.

Fast-acting switches and high speed transducers are used.

The gross stack current is 1.3 of the nominal current.

6

Page 7: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Dynamic Performance of PEMFCAccurate transient response

using experimenta

l set-up

Data log file

7

Page 8: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Dynamic Performance of PEMFC

Rp

RLoad

Continuous

pow ergui

current

f uel f low rate

Air f low rate

fuel flow rate regulator1

v

+

-simout2

To Workspace2

simout1

To Workspace1

simout

To Workspace

Scope3

Scope2

Scope1

g m

1 2

Ideal Switch

[I]

Goto3

[Pulse]

Goto2

[V]

Goto1

[A]

GotoFuelFr

AirFr

m

+

-

Fuel Cell Stack1

[I]

From3

[Pulse]

From2

[V]

From1

[A]

From

i

+

-

Breaker Control

<Voltage><Voltage>

<Current>

<Stack Ef f iciency (%)>

<Stack consumption (Standard lpm) [Air(Yellow); Fuel(Magenta)]>

<Flow Rate (lpm) [Air(Yellow); Fuel(Magenta)]>

<Stack consumption (lpm) [Air(Yellow); Fuel(Magenta)]>

<Utilization (%) [O2(Yellow); H2(Magenta)]>

<Slope of Taf el curv e>

<Exchange current i0 (A)>

<Nerst v oltage En (V)><Nerst v oltage En (V)>

<Open circuit v oltage Eoc (V)>

DC bus current

DC bus v oltage

Fuel cell model of test with resistive load

8

Page 9: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Dynamic Performance of PEMFC

Simulated Transient Response of FC model

4 5 6 7 8 9 10 11 12 13 140

10

20

30

40

50

60

70

Time (s)

Sta

ck V

olta

ge (V

), S

tack

Cur

rent

(A)

Stack Current

Stack Voltage

9

Page 10: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

FC Converter Features

The clamp switch gives zero voltage switching (ZVS) for all switches at turn on and alleviates the usual voltage ringing across the bridge switches (S1~S4);

At turn off the voltage across all switching devices is clamped to the capacitor voltage.

The output rectifier diodes operate with zero current switching (ZCS).

Full bridge with voltage doubler technique results in reduced voltage across output capacitors and diode rectifier. Minimizes the voltage rating of the semiconductor devices. Reduces the turn ratio of high frequency transformer to half that of the conventional FBCFC.

FBCFC for FC system

S4

S3

S2

Lb=475µH iLb

vfc =50-26V

C1

HF Tr.

5:37

D2

io

vo

+

-

Ro

LLK=2µH D1

S1

C2

Cp1 Cp3

Cp2 Cp4

Cpc

A

B

iLk vpri

Ca

Sc

iCa

vSc

vCa

ic1

ic2

10µF Cp1~ Cp4=16nF

C1= C2=400µF

9nF

S1~S4=SKM120B020

Sc=IXFK73N30

D1= D2= C2D05120A

Untapped secondary winding transformer simplifies the transformer construction, improves window utilization, and results in lower leakage inductance.

10

Page 11: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Controller Design

Initially an analogue PI was designed for the FBCFC based on its small signal transfer functions .

Digital average current (DAC) mode control and predictive current control (PCC) techniques can be used for the system.

Since FC takes 0.24 second to respond after a sudden load application from no-load DAC is selected without need for a complex control algorithm.

Two-loop PI digital controller

11

Page 12: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Controller Design

The designed digital controller takes into account the sampling delay (Hsmp) and the computation delay (Hc).

Two PI controllers with anti-windup protection were designed and their optimal parameters obtained using the Control Design Toolbox in Matlab.

Based on the designed digital controller loop for the FBCFC, the transfer function for the current, voltage and overall open loop response of the system are obtained .

12

Page 13: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Controller Design

Bode Plot of Current Controller Open Loop

The plot indicate that inner loop Cid(z) gain has a desired crossover frequency at 5kHz with a phase margin of 590.

Digital PI parameters for Cid(z) are: Kpc= 0.1147, and Kic= 506.66.

13

Page 14: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Controller Design

Bode Plot of Voltage Controller Open Loop

To accommodate the slow FC response, low bandwidth is used for voltage loop Cvi(z).

The voltage loop has a crossover frequency of 149Hz and a phase margin of 58.70.

Digital PI parameters for Cvi(z) are: Kpv = 1.08625,Kiv = 100.748

14

Page 15: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

Controller Design

Bode Plot of Overall Open Loop System

Due to the active clamp the resonance is absence.

The plots show that the bandwidth and phase margin of the controller system are designed as desired.

15

Page 16: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

simulation results

Output voltage waveform during load changes

The simulated dynamic response of the converter at sudden load changes shows that the voltage recovers to its steady-state value within 15m sec.

Designed PI digital controller has been implemented in a DSP; the on-chip ADC converter, PWM “compare function” and other functions were emulated in Simulink.

16

Page 17: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

control algorithm implementation

NO

NO

YES

Update Duty Cycle of PWM

DE =5%

DE < 5%?

YES DE > 42%?

END

Receiving Data from the Host Setting the RTDX in non-blocking

mode

Update Compare Register 2 CMPR2 =TPR-CMPR1

NO

YES

DE =42%

0.506*T1PR > CMPR1 > 0.725*T1PR

Initialization of DSP Event manager (EVA) initialization Enabling PIE peripheral interrupts Setting ACTR register, setting

PWM1&PWM3 active high and PWM2&PWM4 active low

Setting DPTCONx Register

Start

IQ math library in CCS is used for the PI compensators, ADC results and ADC and PWM scaling factors.

The number of GP timers in a DSP is limited to four. The PWM signals for all switches are generated using only one GP timer with dead-band zone. Flow chart of the overlap PWM

algorithm for FBCFC

17

Page 18: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

control algorithm implementation

Software block diagram of 32-bit PI digital control for voltage and current

loop

IQ_Nmpy IQN×IQN

Kp

IQ_Nmpy IQN×IQN

Ki IQ_Nmpy IQN×IQN

Kcorr

max

min

1/Z +

+

+ + + + + -

Ref

FDB Saturation

Anti-windup

-

32-bit PI controller

Fbk

18

Page 19: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

converter system implementation

FBCFC with voltage doubler but without clamp circuit:

secondary voltage (ch3), drain-source voltage across S1 (ch4)

The sampling frequencies are chosen 20 kHz for the current-loop and 2.5 kHz for the voltage-loop controllers.

The FBCFC without clamp circuit shows high voltage overshoots across the MOSFETs resulting in increase switching and conduction losses and reducing the converter’s efficiency.

Proposed FBCFC: primary voltage (ch3), FC current

(ch4), clamp switch voltage (ch2)

19

Page 20: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

converter system implementation

Simulated and Experimental Converter

Efficiency

20

Page 21: D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS

conclusions

FC experiments showed that the number of measurement points using Nexa log file is not sufficient to plot the accurate transient response characteristics of the FC stack. It is observed that the modelled FC matches very well with the real FC system results

A two-loop digital controller with anti-windup protection has been developed for a 1.2kW active clamp FBCFC topology with a voltage doubler.

The experimental results have validated the accurate modelling for the FC converter system.

Simulation and practical measurements of the proposed converter and other configurations at different loads have shown that the proposed configuration has the highest efficiency.