13
D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. * ,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers University Flow Dynamics in Left-Main Bifurcation

D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

  • Upload
    job-lee

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Page 1: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD **

L. CHRISTAENS M.D. * ,J MERGY MD *, P. BRAUD PhD **

*Poitiers University Hospital. **CNRS-Poitiers University

Flow Dynamics in Left-Main Bifurcation

Page 2: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

WSS and endothelium

From Chatzisisis JACC 2006

WSS is determined from velocity gradient and viscosityA negative correlation was found between intimal thickness and WSSLow WSS is strongly correlated to atherogenesisThe low WSS values distribution is in accordance with the frequent localization of atherosclerosis lesion

Page 3: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Atherosclerotic plaque distribution in LMCT Scan study

• LM bifurcation:

L Christiaens study :

• “Distribution of atherosclerotic plaques in the left main coronary artery bifurcation: influence of anatomic variations of the proximal left coronary artery segments. A multi-slice computed tomography study over 300 cases. ”

Page 4: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Atherosclerotic plaque distribution in LMCT Scan study

Atherosclerotic plaque distribution in LMCT Scan study

More than 70% of plaques are located close to low WSS zones

Page 5: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

French TAXUS registry• Impact of bifurcation angle ??. T Shape vs Y Shape

EBC 2007Valencia

T LefebvreY Louvard

Page 6: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

• Objective :

-Effect of the bifurcation angle on flow dynamic in case of provisional stenting of LM bifurcation

-Trajectography , Langragian approach

Page 7: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

• Experimental setup :

Oscilloscope

Pulsatil pump

Centrifugal Pump

by-pass

BifurcationUnstead

y Flowmet

er

Laser sheet

CCD Camera

Page 8: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

• Experimental setup :

Modelisation :

Synthetic flow : Arbitrary Wave Generator . + pulsatil pump

Bifurcation models in glass (90°,60°)

Ultra-fast PIV measurements (3 kHz – 1024x1024 – 50 periods )

Standard PIV (50 pts/period – 50 periods – 2Hz )

Scale 1, Reynolds analogy (Water+glycerin)

Silver Hollow glass (15micron diameter)

-1

-0.5

0

0.5

1

1.5

-0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6

Time (=>N=2Hz)

Vol

tage

(mV

)

Page 9: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

• Experimental device :

For 60° and 90° bifurcation angles

Normal bifurcation Without stent

With stent before Kissing procedure

With stent lateral struts openProvisional stenting , proximal crossing

Page 10: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

• Provisional stenting

Page 11: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

• Natural bifurcation :• 60° Bifurcation : • 90° Bifurcation :

Low velocity gradient zones/ Low WSS

Page 12: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.Stent before kissing procedure

• 60° Bifurcation : • 90° Bifurcation :

RecirculationShadow area3D phenomenon

Page 13: D. COISNE M.D. Ph.D *, E. FOUCAULT PhD**, S HUBERSON PhD ** L. CHRISTAENS M.D. *,J MERGY MD *, P. BRAUD PhD ** *Poitiers University Hospital. **CNRS-Poitiers

Flow dynamics in LM Bifurcation.

Stent provisional stenting • 60° Bifurcation : • 90° Bifurcation :

RecirculationShadow area3D phenomenon