Upload
tariq-mehmood
View
36
Download
7
Embed Size (px)
Citation preview
CURRENT ADDRESS:
Asset Maintenance Department Dammam Saudi Arabia.
PERMANENT ADDRESS:
Village and post office Mughal Chak Kalan Tehsil & District Gujranwala, Punjab, Pakistan.
EMAIL: [email protected]
CELL: +92-307-6190327, +92-335-1408001, +966-544831272
CAREER OBJECTIVE:
Seeking a Position as Associate Electrical Engineer with a Progressive Company that Provides Opportunity for Career Growth and Job Satisfaction, as a Productive Team Member
PROFESSIONAL EXPERIENCE (10 YEARS)
Since Aug-2003 In Gujranwala Electric Power Company (GEPCO). www.gepco.gov.pk Having Experience with the Various Departments like , Grid Station maintenance and protection, of the substation equipments.
PROFESSIONAL EXPERIENCE (1 + YEAR)
SINCE NOV-2013 INSAUDI ELECTRICITY COMPANY (SEC) Having Experience with the Various Departments like , GIS Grid Station maintenance and protection, of the substation equipments.
TRAININGS:
I attended 32 weeks training of P&I at GSO Training Centre Tarbela and TSG Training Centre NKLP Lahore.
I attended 2 weaks training of GIS Installation and Maintenace from HYUNDAI COMPANY.
I atended 2 Days training of AC and DC wiring trouble shooting and Maintenance from ABB COMPANY.
I attended 1 weak training of SAFETY from Saudi Electricity Company.
I attended 1 day training of FIRST AID from SEC MEDICAL CENTRE. .
Duties & Responsibilities:
Power Transformer Augmentation & Replacement of Power Transformers 40 MVA & below. Commissioning & Testing of New Power Transformers 40 MVA & below. Scheduled & Emergency Testing of Power Transformer
1 | P a g e
TARIQ MEHMOOD11 + Years Experience (Associate Electrical Engineer)
Testing of Power Transformer Winding Insulation Resistance, T.T.R.(Transformer Turn Ration), C&DF(Capacitance & Dissipation Factor), Winding Resistance, Open & Short Circuit, , DES of Oil
Commissioning/Testing of 380, 230, 115/13.8 kv C.B Commissioning /Testing of 380, 230, 115/13.8 kv C.B Troubleshooting /emergencies of 380, 230, 115/13.8 kv C.B Open/Close Timing of 380, 230, 115/13.8 kv C.B Contact Resistance of 380, 230, 115/13.8 kv C.B Magger/hi pot insulation test of 380, 230, 115/13.8 kv C.B
Relays Testing of Differential Relay for Power Transformer Testing of Distance Relays for 132 KV & 66 KV Transmission Lines Testing , Programming/Setting of Over Current & Earth Fault Relays for Power Transformer, 132 KV &
66 KV Transmission Lines. Testing, Programming/Setting of Over & Under Voltage Relays, Unbalanced Relay for 11 KV Capacitors Installation & Testing Auxiliary Relays like VAJ(Tripping Relays), VAX(Supervision Relays), DC
Supervision Relay, PT Supervision Relay etc Testing & Wiring of Main Buchholz Relay , OLTC Protective Relay of Power Transformer
Others Protection Over Current & Earth Fault Protection of 11 KV Feeders Installation, Testing & Setting of Oil & Winding Temperature Protection Gauges Annunciations of Power Transformers & Transmission Lines
Metering Installation of New KWh & KVarh Meters, Ampere Meters, KV Meters, Power Factor Meters, Frequency
Meters, Watt Meters etc Testing & Calibration of All Meters installed on Grid Stations
Other Sub Station Equipments Commissioning & Testing of 132/66/11 KV CTs, PTs, Lighting Arrestors Testing of Earth Mesh Commissioning & Testing of 11 KV Panels, Capacitor Panels, AC/DC Panels, Control Panels, Relay Panels,
Auxiliary Panels etc Commissioning & Testing of 11 KV Capacitor Banks Installation & Testing of Various AC/DC Alarms/Hooters and Annunciations
Having Skill/Ability of Using Testing Sets:
Transformer Turn Ratio (TTR): Phenix Technologies USAPATTR – 03 Auto Transformer Turn Ratio tester USA
Winding Resistance Of P/T: DIGITAL OHMMETER, PME 10 SMC, 25 VAWinding Insulation Resistance Of P/T: MEGGER, 10KV DCC&DF Of P/T, CTs & PTs: MULTIAMP CB-100, USACircuit Breaker Timing: TM 1600 ProgramaCircuit Breaker Contact Resistance: MICROMETER, MOM 600A PROGRAMAInsulation Resistance: DC Hi POT 80 KV & DC Megger 10KVEarth Resistance: FOSO Electric, F-362, JapanSF6 Ananlyzer Die Electric Strength of P/T Oil: FOSTER MEGGER 80KVPrimary Injection: PROGRAMASecondary Injection: PROGRAMA
REWARD AND ACHEIVEMNTS
Got 1st Division in DAE.(Electrical) Got 1st Division in Matric.(Science)
EDUCATION
2007: 03 YearsDiploma ; Associate Engineer . (Electrical )Punjab Board of Technical Education Lahore Pakistand 1st Division
2 | P a g e
2000Govt High School Qila Mian Singh Tehsil & District Gujranwala, Pakistan
1st Division
COMPUTER SKILLS
MS Windows (98…2002…XP), MS Office (97...2007…XP), Typing, , Internet, Emailing, etc
LANGUAGES
English: Good Conversational and Very Good Technical & Professional English. I am Improving my English all time. Punjabi: NativeUrdu: Excellent
PERSONAL INFORMATION
Father’s Name: Muhammad AshiqueBirth Date: 5th Nov 1981Gender: MaleNationality: PakistaniResidence Location: Gujranwala, PakistanMarital Status: Married
3 | P a g e