    CV8312: Steel-skinned Composite Structural Systems K.M. Anwar Hossain, PhD, PEng

    1

    ASSIGNMENT 1

    Plain steel plated shear panels

    (To be submitted after two weeks)

    Fig. 1 shows plan and elevation of a seven-storey steel framed shear wall building with steel-platedin-fill walls acting as shear panels. The shear panels are made of flat steel plates. Assume the

    following data:

    Width of the building, b = 5.0m + Student Serial No.Storey height, h = 3.5 m

    Distance between the frame, B = 10.0 m + Student Serial No.

    Yield stress of steel plate, fy = 350 MPaPoissons ration of steel plate, s = 0.25

    Modulus of elasticity of steel plate, Es = 200 kN/mm2

    Fig. 1: Plain steel plated shear wall building

    i. Assuming rigid pin-ended boundary frames, find the shear resistance of the steel platedshear panels if the thickness of the steel plate varies from 1 mm, 10 mm, 20 mm and 50

    mm using various analytical models described in the class. Identify whether the shearresistance of the steel plated shear panels will be governed by pure tension field,

    incomplete tension field or pure shear, for each of the steel plate thickness.

    With the help of graphs and charts, discuss the influence of steel plate thickness on

    buckling stress, buckling load, pre-buckling stiffness, ultimate shear resistance and

    stiffness, and failure modes of shear panels.

    If a steel plate of thickness 10 mm is used in the building (as shown in Fig. 1), find out

    whether the shear resistance of the steel plated shear panels will be adequate or not in

    B

    h

    b

    Wind load, w

    Shear

    panel

    Buildingframe

    Elevation

    Plan

    Frame

  • 8/7/2019 CV 8312- Assignment 1

    2/2

    CV8312: Steel-skinned Composite Structural Systems K.M. Anwar Hossain, PhD, PEng

    2

    resisting a wind load (w) of 1 kN/m2. Find the minimum thickness of the steel plate,

    necessary to resist a wind load (w) of 1 kN/mm2.

    ii. Assuming beam-column frame to be flexible and beam-column frame connections are

    fixed and plastic hinges to form in the beams (Fig. 1):

    Determine the ultimate shear resistance of in-fill shear panels made of 1, 5, 10 and 20

    mm thick steel plates with beams having variable flexibility (consider beam plastic

    moment, Mp varying from 0 to 400 kN.m at an increment of 100 kN.m) using Basler,Rocky & Skaloud, Cardiff and Hossain models.

    Discuss the influence of variable steel plate thickness and Mp on location of plastichinges (c) and ultimate shear resistance with graphs and charts. Also compare the

    performance of various models in predicting the shear resistance of the panels.