23
Summary Data For PIQ-2G18G-360-16-CD-1 11 Power Supply +12 to +15V @ 100 mA -12 to -15V @ 100 mA +15 @ 52 mA -15 @ 76 mA QA/QC Approval: Date: 9 Control Slopes Linear Verified 10 Switching Speed 500 nSec MAX. 416nSec 7 Phase vs. Frequency (Flatness) ±20.0° TYP. ±16.24° @ 0 dB Attenuation ±21.26° @ 8 dB Attenuation ±37.61° @ 16 dB Attenuation 8 Control Logic 2 x 12 BITs (I and Q) TTL compatible. Verified 5 VSWR 2.2:1 MAX 2.07:1 6 Attenuation vs. Frequency ±3.5 dB TYP. ±1.75 dB @ 0 dB Attenuation ±3.03 dB @ 8 dB Attenuation ±7.37 dB @ 16 dB Attenuation 3 Dynamic Range 16 dB 16 dB 4 Insertion Loss 16 dB MAX 15.78 dB 1 Frequency Range 2.0 GHz to 18.0 GHz 2.0 GHz to 18.0 GHz 2 Phase Range 360° 360° Serial No: PL21997/1802 Drawing No: 27327882 Rev: 1 TEST ITEM NO PARAMETERS SPECIFIED VALUE TEST RESULTS QA QC Customer: Tested By: K. Mansfield SO No: Temperature: +25°C Model No: PIQ-2G18G-360-16-CD-1 Date 1/9/2018 7311F Grove Road Frederick, MD 21704 USA Phone: (301)6625019 Fax: (301)6621731 Website: www.pmirf.com Email: sales@pmirf.com Page 1 of 23

Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1

11 Power Supply+12 to +15V @ 100 mA -12 to -15V @ 100 mA

+15 @ 52 mA-15 @ 76 mA

QA/QC Approval: Date:

9 Control Slopes Linear Verified

10 Switching Speed 500 nSec MAX. 416nSec

7Phase vs. Frequency

(Flatness)±20.0° TYP.

±16.24° @ 0 dB Attenuation±21.26° @ 8 dB Attenuation

±37.61° @ 16 dB Attenuation

8 Control Logic2 x 12 BITs (I and Q) TTL

compatible. Verified

5 VSWR 2.2:1 MAX 2.07:1

6Attenuation vs.

Frequency±3.5 dB TYP.

±1.75 dB @ 0 dB Attenuation±3.03 dB @ 8 dB Attenuation

±7.37 dB @ 16 dB Attenuation

3 Dynamic Range 16 dB 16 dB

4 Insertion Loss 16 dB MAX 15.78 dB

1 Frequency Range 2.0 GHz to 18.0 GHz 2.0 GHz to 18.0 GHz

2 Phase Range 360° 360°

Serial No: PL21997/1802 Drawing No: 27327882 Rev: 1

TEST ITEM NO

PARAMETERS SPECIFIED VALUE TEST RESULTS QA QC

Customer: Tested By: K. Mansfield

SO No: Temperature: +25°C

Model No: PIQ-2G18G-360-16-CD-1 Date 1/9/2018

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 1 of 23

Page 2: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23. Insertion Loss Vs. Phase @ 16 dB Attenuation (PM/AM): ········································

Attenuation Vs. Frequency @ 0 dB Attenuation (PM/AM): ······································

Page 5 Attenuation Vs. Frequency @ 4 dB Attenuation (PM/AM): ······································

Page 6

Summary Data: ···········································································································

Page 3 Inserstion Loss Vs. Frequency: ···················································································

Page 4

Attenuation Vs. Frequency @ 16 dB Attenuation (PM/AM): ····································

Page 9 Input/Output Return Loss Vs. Frequency @ 0 dB Attenuation: ·································

Page 10

Attenuation Vs. Frequency @ 8 dB Attenuation (PM/AM): ······································

Page 7 Attenuation Vs. Frequency @ 12 dB Attenuation (PM/AM): ····································

Page 8

Table of Contents: ······································································································· Page 2

Input/Output Return Loss Vs. Frequency @ 12 dB Attenuation: ·······························

Page 13 Input/Output Return Loss Vs. Frequency @ 16 dB Attenuation: ·······························

Page 23

Insertion Loss Vs. Phase @ 4 dB Attenuation (PM/AM): ··········································

Page 21 Insertion Loss Vs. Phase @ 8 dB Attenuation (PM/AM): ··········································

Page 22

Phase @ 16 dB Attenuation: ·······················································································

Page 19 Insertion Loss Vs. Phase @ 0 dB Attenuation (PM/AM): ··········································

Page 20

Table Of Contents

Page 14

Input/Output Return Loss Vs. Frequency @ 4 dB Attenuation: ·································

Page 11 Input/Output Return Loss Vs. Frequency @ 8 dB Attenuation: ·································

Page 12

Phase @ 8 dB Attenuation: ·························································································

Page 17 Phase @ 12 dB Attenuation: ·······················································································

Page 18

Phase @ 0 dB Attenuation: ·························································································

Page 15 Phase @ 4 dB Attenuation: ·························································································

Page 16

Page 1

Insertion Loss Vs. Phase @ 12 dB Attenuation (PM/AM): ········································

Phase State Legend

Phase 1 (11.25 °) Phase 2 (22.5 °) Phase 3 (33.75 °) Phase 4 (45 °)

Phase 5 (56.25 °) Phase 6 (67.5 °) Phase 7 (78.75 °) Phase 8 (90 °)

Phase 9 (101.25 °) Phase 10 (112.5 °) Phase 11 (123.75 °) Phase 12 (135 °)

Phase 13 (146.25 °) Phase 14 (157.5 °) Phase 15 (168.75 °) Phase 16 (180 °)

Phase 17 (191.25 °) Phase 18 (202.5 °) Phase 19 (213.75 °) Phase 20 (225 °)

Phase 21 (236.25 °) Phase 22 (247.5 °) Phase 23 (258.75 °) Phase 24 (270 °)

Phase 25 (281.25 °) Phase 26 (292.5 °) Phase 27 (303.75 °) Phase 28 (315 °)

Phase 29 (326.25 °) Phase 30 (337.5 °) Phase 31 (348.75 °) Phase 32 (360 °)

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 2 of 23

Page 3: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐18

‐17

‐16

‐15

‐14

‐13

‐12

‐11

‐10

‐9

‐8

‐7

‐6

2 4 6 8 10 12 14 16 18

Insertion Loss (dB)

Frequency (GHz)

Inserstion Loss Vs. Frequency

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 3 of 23

Page 4: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐3.5

‐2.5

‐1.5

‐0.5

0.5

1.5

2.5

3.5

2 4 6 8 10 12 14 16 18

Atten

uation (dB)

Frequency (GHz)

Attenuation Vs. Frequency @ 0 dB Attenuation (PM/AM)

0

1

2

3

2 4 6 8 10 12 14 16 18

Amplitude Variation (±d

B)

Frequency (GHz)

Maximum Amplitude Variation From Center Vs. Frequency @ 0 dB Attenuation (PM/AM)

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 4 of 23

Page 5: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐8

‐7

‐6

‐5

‐4

‐3

‐2

‐1

0

2 4 6 8 10 12 14 16 18

Atten

uation (dB)

Frequency (GHz)

Attenuation Vs. Frequency @ 4 dB Attenuation (PM/AM)

0

1

2

3

2 4 6 8 10 12 14 16 18

Amplitude Variation (±d

B)

Frequency (GHz)

Maximum Amplitude Variation From Center Vs. Frequency @ 4 dB Attenuation (PM/AM)

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 5 of 23

Page 6: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐12

‐11

‐10

‐9

‐8

‐7

‐6

‐5

‐4

2 4 6 8 10 12 14 16 18

Atten

uation (dB)

Frequency (GHz)

Attenuation Vs. Frequency @ 8 dB Attenuation (PM/AM)

0

1

2

3

2 4 6 8 10 12 14 16 18

Amplitude Variation (±d

B)

Frequency (GHz)

Maximum Amplitude Variation From Center Vs. Frequency @ 8 dB Attenuation (PM/AM)

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 6 of 23

Page 7: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐16

‐15

‐14

‐13

‐12

‐11

‐10

‐9

‐8

2 4 6 8 10 12 14 16 18

Atten

uation (dB)

Frequency (GHz)

Attenuation Vs. Frequency @ 12 dB Attenuation (PM/AM)

0

1

2

3

2 4 6 8 10 12 14 16 18

Amplitude Variation (±d

B)

Frequency (GHz)

Maximum Amplitude Variation From Center Vs. Frequency @ 12 dB Attenuation (PM/AM)

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 7 of 23

Page 8: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐28

‐26

‐24

‐22

‐20

‐18

‐16

‐14

‐12

2 4 6 8 10 12 14 16 18

Atten

uation (dB)

Frequency (GHz)

Attenuation Vs. Frequency @ 16 dB Attenuation (PM/AM)

0

1

2

3

2 4 6 8 10 12 14 16 18

Amplitude Variation (±d

B)

Frequency (GHz)

Maximum Amplitude Variation From Center Vs. Frequency @ 16 dB Attenuation (PM/AM)

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 8 of 23

Page 9: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Input Return Loss Vs. Frequency @ 0 dB Attenuation

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Output Return Loss Vs. Frequency @ 0 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 9 of 23

Page 10: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Input Return Loss Vs. Frequency @ 4 dB Attenuation

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Output Return Loss Vs. Frequency @ 4 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 10 of 23

Page 11: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Input Return Loss Vs. Frequency @ 8 dB Attenuation

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Output Return Loss Vs. Frequency @ 8 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 11 of 23

Page 12: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Input Return Loss Vs. Frequency @ 12 dB Attenuation

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Output Return Loss Vs. Frequency @ 12 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 12 of 23

Page 13: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Input Return Loss Vs. Frequency @ 16 dB Attenuation

‐50

‐45

‐40

‐35

‐30

‐25

‐20

‐15

‐10

‐5

2 4 6 8 10 12 14 16 18

Return Loss (dB)

Frequency (GHz)

Output Return Loss Vs. Frequency @ 16 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 13 of 23

Page 14: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐20

10

40

70

100

130

160

190

220

250

280

310

340

370

2 4 6 8 10 12 14 16 18

Phase (°)

Frequency (GHz)

Phase @ 0 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 14 of 23

Page 15: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐20

10

40

70

100

130

160

190

220

250

280

310

340

370

2 4 6 8 10 12 14 16 18

Phase (°)

Frequency (GHz)

Phase @ 4 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 15 of 23

Page 16: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐20

10

40

70

100

130

160

190

220

250

280

310

340

370

2 4 6 8 10 12 14 16 18

Phase (°)

Frequency (GHz)

Phase @ 8 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 16 of 23

Page 17: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐20

10

40

70

100

130

160

190

220

250

280

310

340

370

2 4 6 8 10 12 14 16 18

Phase (°)

Frequency (GHz)

Phase @ 12 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 17 of 23

Page 18: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐20

10

40

70

100

130

160

190

220

250

280

310

340

370

2 4 6 8 10 12 14 16 18

Phase (°)

Frequency (GHz)

Phase @ 16 dB Attenuation

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 18 of 23

Page 19: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐20

‐15

‐10

‐5

0

5

10

15

20

‐20 ‐15 ‐10 ‐5 0 5 10 15 20

Y‐Axis (dB)

X‐Axis (dB)

Insertion Loss Vs. Phase @ 0 dB AttenuationInsertion Loss = ((X^2)+(Y^2))^0.5

‐5‐4‐3‐2‐1012345

0 50 100 150 200 250 300 350

Variation dB

Phase (°)

Amplitude Linearity Vs. Phase @ 0 dB Attenuation (PM/AM)

2 GHz 4 GHz 6 GHz 8 GHz 10 GHz 12 GHz 14 GHz 16 GHz 18 GHz

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 19 of 23

Page 20: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐25

‐20

‐15

‐10

‐5

0

5

10

15

20

25

‐25 ‐20 ‐15 ‐10 ‐5 0 5 10 15 20 25

Y‐Axis (dB)

X‐Axis (dB)

Insertion Loss Vs. Phase @ 4 dB AttenuationInsertion Loss = ((X^2)+(Y^2))^0.5

‐5‐4‐3‐2‐1012345

0 50 100 150 200 250 300 350

Variation dB

Phase (°)

Amplitude Linearity Vs. Phase @ 4 dB Attenuation (PM/AM)

2 GHz 4 GHz 6 GHz 8 GHz 10 GHz 12 GHz 14 GHz 16 GHz 18 GHz

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 20 of 23

Page 21: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐25

‐20

‐15

‐10

‐5

0

5

10

15

20

25

‐25 ‐20 ‐15 ‐10 ‐5 0 5 10 15 20 25

Y‐Axis (dB)

X‐Axis (dB)

Insertion Loss Vs. Phase @ 8 dB AttenuationInsertion Loss = ((X^2)+(Y^2))^0.5

‐5‐4‐3‐2‐1012345

0 50 100 150 200 250 300 350

Variation dB

Phase (°)

Amplitude Linearity Vs. Phase @ 8 dB Attenuation (PM/AM)

2 GHz 4 GHz 6 GHz 8 GHz 10 GHz 12 GHz 14 GHz 16 GHz 18 GHz

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 21 of 23

Page 22: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐30

‐25

‐20

‐15

‐10

‐5

0

5

10

15

20

25

30

‐30 ‐25 ‐20 ‐15 ‐10 ‐5 0 5 10 15 20 25 30

Y‐Axis (dB)

X‐Axis (dB)

Insertion Loss Vs. Phase @ 12 dB AttenuationInsertion Loss = ((X^2)+(Y^2))^0.5

‐5‐4‐3‐2‐1012345

0 50 100 150 200 250 300 350

Variation dB

Phase (°)

Amplitude Linearity Vs. Phase @ 12 dB Attenuation (PM/AM)

2 GHz 4 GHz 6 GHz 8 GHz 10 GHz 12 GHz 14 GHz 16 GHz 18 GHz

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 22 of 23

Page 23: Customer: Tested By: K. Mansfield SO No: Temperature: +25 ... · PL21997/1802 ‐3.5 ‐2.5 ‐1.5 ‐0.5 0.5 1.5 2.5 3.5 2 4 6 8 10 12 14 16 18 Attenuation

Summary DataFor

PIQ-2G18G-360-16-CD-1PL21997/1802

‐35

‐30

‐25

‐20

‐15

‐10

‐5

0

5

10

15

20

25

30

35

‐35 ‐30 ‐25 ‐20 ‐15 ‐10 ‐5 0 5 10 15 20 25 30 35

Y‐Axis (dB)

X‐Axis (dB)

Insertion Loss Vs. Phase @ 16 dB AttenuationInsertion Loss = ((X^2)+(Y^2))^0.5

‐5‐4‐3‐2‐1012345

0 50 100 150 200 250 300 350

Variation dB

Phase (°)

Amplitude Linearity Vs. Phase @ 16 dB Attenuation (PM/AM)

2 GHz 4 GHz 6 GHz 8 GHz 10 GHz 12 GHz 14 GHz 16 GHz 18 GHz

 7311‐F Grove Road Frederick, MD 21704 USA

Phone: (301)662‐5019  Fax: (301)662‐1731

Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 23 of 23