16
Modular Cabinet Solutions | 1 Custom Telecom Cabinet Solutions Whatever you want to say here.

Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 1

Custom Telecom Cabinet Solutions

Whatever you want to say here.

Page 2: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s
Page 3: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 3

Raycap is a privately-held technology solu-tions provider offering products and services that support and protect the world’s critical telecommunications, energy, transportation and other infrastructure.

Since 1987 Raycap has built a worldwide organization with offices and production facilities throughout Europe and in North America. The company combines advanced engineering, superior product design, sys-tems integration and manufacturing capabil-ity with a deep understanding of the needs of the customer to create unique technologi-cal solutions for mission-critical applications. It also offers engineering services such as custom product design and site surveys, as well as warehousing, logistics, customer training, and much more.

About Raycap

The company’s comprehensive understand-ing of customer needs and the industries in which they operate is crucial to its ability to develop effective products and solutions that integrate the latest technology with the highest quality of service.

The Raycap team of talented, highly expe-rienced staff works together with customers to find the best-fit solutions. As a result, more than half of the products delivered are custom-built for unique customer ap-plications and to their specifications. From rigorous internal and independent testing to a consultative customer-focused approach, Raycap is determined to deliver the high-est quality products with responsiveness, innovation and agility.

M o d u l a r C a b i n e t S o l u t i o n s | 3

Page 4: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

4 | M o d u l a r C a b i n e t S o l u t i o n s

RCAB-OD-9367 Outdoor Cabinet for Active Equipment

M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y

The RCAB-OD-9367 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations over existing cross connect cabinets in parallel with the hosting of active and passive telecom equipment.

Dual wall aluminum Robust design Modular design Easy installation

process Solid profile technology Excellent heat

dissipation 19” technology with

moving frames Cooling capacity by

using heat exchanger Customer specific

integrations Left and Right Type

available, depending on the installation site

1595

1652

1690

AA

126

1 9

0

480

575

80

539,5

EnvironmentalProtection Class IP55

Impact Protection IK10

Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

Earthquake Zone 4

MechanicalConstruction Aluminum alloy

Surface Powder coated, RAL 7035

Dimensions 1430mm (H) x 1652mm (W) x 540mm (D)

Reserved for PSU with DC Distribution 1U 19" (extra 1U for DC terminals)

Reserved for ODF 1U

Reserved for AC PDU 3U

Free User Space 10U 19"

Locking Mechanism 3-point system

Cable Entry Point Bottom

Temperature ControlCooling System Heat exchanger 60W/K

Heater Included

SensorsDoor Alarm Contact Included

Smoke Sensor Included

Temperature Included

Flood Sensor Included

* Modifications according to customer's requests are possible.

Environmental & Mechanical Specifications*

Page 5: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 5

RCAB-OD-6849 Outdoor Cabinet for Active Equipment

The RCAB-OD-6849 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. Due to its small dimensions, the cabinet is the ideal solution for installations in residential areas.

Dual wall aluminum Robust design Modular design Easy installation

process Solid profile technology Excellent heat

dissipation 19” technology with

moving frames Cooling capacity by

using heat exchanger Customer specific

integrations 1198,2

1188

BB

AA

444

180

1

333

8,7

429,5

Environmental & Mechanical Specifications*

EnvironmentalProtection Class IP55

Impact Protection IK10

Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

Earthquake Zone 4

MechanicalConstruction Aluminum alloy

Surface Powder coated, RAL 7035

Dimensions 1520mm (H) x 1188mm (W) x 430mm (D)

Reserved for PSU with DC Distribution 1U 19" (extra 1U for DC terminals)

Reserved for ODF 1U

Reserved for AC PDU 3U

Free User Space 10U 19"

Locking Mechanism 3-point system

Cable Entry Point Bottom

Temperature ControlCooling System Heat exchanger 60W/K

Heater Included

SensorsDoor Alarm Contact Included

Smoke Sensor Included

Temperature Included

Flood Sensor Included

* Modifications according to customer's requests are possible.

Page 6: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

6 | M o d u l a r C a b i n e t S o l u t i o n s

RCAB-OD-7474 MFG 12 Outdoor Cabinet for Active & Passive Equipment

RCAB-OD-7474 is a modular double-wall multifunctional cabinet that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet with cooling technology is installed outdoors and due to its small dimensions the cabinet is the ideal solution for installations in residential areas.

Dual wall aluminum Robust design 100% Modular design Cabinet parts are

replaceable without service interruption

Excellent passive heat conductivity

Cooling system including heat exchanger

Customer specific integrations

500

M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y

Environmental & Mechanical Specifications*

EnvironmentalProtection Class IP54

Operating Temperature -33ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 )

Storage Temperature -33ºC to +45ºC (according to ETSI 300 019-1-1, Class 1.3)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

Resistance Class EN 1627:2011,RC2

MechanicalConstruction Aluminum

Surface Powder coated, RAL 7035

Dimensions 1400mm (H) x 1450mm (W) x 500mm (D)

Racks 2xETSI Racks 38SU, 3-bay system mountable in ETSI Rack

Locking Mechanism 3-point system

Cable Entry 1x splitted cable entry plate with 12 grommets

Doors 2 with door stopper

1x Swivel handle**

Plinth Magnelis, 4 adjustable leveling feet

Plastics High recyclable, halogen free

Specification TS0273/96

Temperature ControlCooling System Heat exchanger

SensorsTemperature Included

* Modifications according to customer's requests are possible.

** Locking mechanism available upon request.

Page 7: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 7

RCAB-OD-8040 MFG 15Outdoor Cabinet for Active & Passive Equipment

1700

145

0

500

Environmental & Mechanical Specifications*

EnvironmentalProtection Class IP54

Resistance Class RC2

Operating Temperature -33ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1)

Storage Temperature -33ºC to +45ºC (according to ETSI 300 019-1-1, Class 1.3)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

MechanicalConstruction Aluminum

Surface Powder coated, RAL 7035

Racks 1x19"/ETSI 38 SU, 1xTelecom rack

Locking Mechanism 3-point locking system

Doors 2 with door stopper

1x Swivel handle**

Cable Entry 1x Universal foam in MDF area,

1x Splitted cable entry plate with grommet in ETSI rack area

Dimensions 1700mm (H) x 1450mm (W) x 500mm (D)

Plinth Stainless steel, 4 adjustable leveling feet

Plastics High recyclable, halogen free

Temperature ControlCooling System Heat exchanger

SensorsTemperature Sensor Included

* Modifications according to customer's requests are possible.

** Locking mechanism available upon request.

RCAB-OD-8040 is a modular double-wall multifunctional cabinet that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet with cooling technology is the ideal solution for installations over existing cross connect cabinets in parallel with the hosting of active and passive telecom equipment.

Double wall aluminum Robust design 100% modular design Cabinet parts are

replaceable without service interrruption

Excellent passive heat conductivity

Cooling system including heat exchanger

Customer specific integrations

Left and right type available

Page 8: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

8 | M o d u l a r C a b i n e t S o l u t i o n s

RCAB-OD-5306 MFG 18Outdoor Cabinet for Active & Passive Equipment

2000

160

0

500

Environmental & Mechanical Specifications*

EnvironmentalProtection Class IP54

Resistance Class EN 1627:2011, RC2

Operating Temperature -33ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1)

Storage Temperature -33ºC to +45ºC (according to ETSI 300 019-1-1, Class 1.3)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

MechanicalConstruction Aluminum

Surface Powder coated, RAL 7035

Racks MFG10 18 : 3xETSI 38SU, 3-bay system mountable in ETSI Rack

MFG10 18Ü : 1xETSI 38SU, 1x triple telecom rack

Locking Mechanism 3-point locking system

Doors 2 with door stopper

1x Swivel handle**

Cable Entry MFG10 18 : 1xSplitted cable entry plate with 18 grommets

MFG10 18Ü : 1xUniversal foam in the MDF area, 1xSplitted cable

entry plate with grommets in the ETSI rack area, 1xSplitted cable

entry plate with grommets in the telecom rack area

Dimensions 2000mm (H) x 1600mm (W) x 500mm (D)

Plinth Magnelis, 4 adjustable leveling feet

Plastics High recyclable, halogen free

Specification TS0273/96

Temperature ControlCooling System 2xHeat exchanger

SensorsTemperature Sensor Included

* Modifications according to customer's requests are possible.

** Locking mechanism available upon request.

RCAB-OD-5306 is a modular double-wall multifunctional cabinet that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet with cooling technology is installed outdoors and is the ideal solution for hosting demanding and sensitive active and passive equipment.

Double wall aluminum Robust design 100% modular design Cabinet parts are

replaceable without service interrruption

Excellent passive heat conductivity

Cooling system including heat exchanger

Customer specific integrations

Left and right type available

M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y

Page 9: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 9

RCAB-OD-1657 Outdoor Cabinet for Active Equipment

Environmental & Mechanical Specifications*

The RCAB-OD-1657 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations hosting active and passive telecom equipment.

Dual wall aluminum Robust design Modular design Easy installation

process Solid profile technology Excellent heat

dissipation 19" technology with

moving frames Cooling capacity by

using heat exchanger Customer specific

integrations

732

790

592

650

8095

1120

EnvironmentalProtection Class IP55

Impact Protection IK10

Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

Earthquake Zone 4

MechanicalConstruction Double Aluminum alloy

Surface Powder coated, RAL 7035

Dimensions 1295mm (H) x 790mm (W) x 650mm (D)

Reserved for PSU with DC Distribution 1U 19"

DC to AC Inverter 400W Included

AC PDU Included

MDF Space for 20x10 LSA PLUS, 2x64 Splitter Modules

Free User Space 6U 19"

Locking Mechanism 3-point system

Cable Entry Point Bottom

Temperature ControlCooling System Heat exchanger

Heater Included

SensorsDoor Alarm Contact Included

Smoke Sensor Included

Temperature Included

Flood Sensor Included

* Modifications according to customer's requests are possible.

Page 10: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

10 | M o d u l a r C a b i n e t S o l u t i o n s

RCAB-OD-1171Outdoor Cabinet for Active Equipment

Environmental & Mechanical Specifications*

The RCAB-OD-1171 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations of active & passive telecom equipment.

Dual wall aluminum Robust design Modular design Easy installation

process Solid profile technology Excellent heat

dissipation ETSI technology with

moving frames Cooling capacity by

using heat exchanger Customer specific

integrations Left and Right Type

available, depending on the installation site

EnvironmentalProtection Class IP55

Impact Protection IK10

Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

Earthquake Zone 4

MechanicalConstruction Double Aluminum alloy

Surface Powder coated, RAL 7035

Dimensions 1503mm (H) x 1720mm (W) x 637mm (D)

Reserved for PSU with DC Distribution 5U

Reserved for ODF 1U

Reserved for AC PDU 3U

Free User Space 2x24U ETSI Rack

Locking Mechanism 3-point system

Cable Entry Point Bottom

Temperature ControlCooling System Heat exchanger

Heater Included

SensorsDoor Alarm Contact Included

Smoke Sensor Included

Temperature Included

Flood Sensor Included

* Modifications according to customer's requests are possible.

1677

1720

1770

916

.5

637

80

132

3 1

00

594

637

80

637

142

3

594

637

406

.5

M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y

Page 11: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 11

RCAB-OD-2027 Outdoor Cabinet for Active Equipment

Environmental & Mechanical Specifications*

EnvironmentalProtection Class IP55

Impact Protection IK10

Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)

Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)

Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)

Earthquake Zone 4

MechanicalConstruction Double Aluminum alloy

Surface Powder coated, RAL 7035

Dimensions 1640mm (H) x 1480mm (W) x 546mm (D)

Reserved for PSU with DC Distribution 2U 19"

Reserved for ODF 1U

Reserved for AC PDU 3U

Free User Space 10U 19"

Locking Mechanism 3-point system

Cable Entry Point Bottom

Temperature ControlCooling System Heat exchanger

Heater Included

SensorsDoor Alarm Contact Included

Smoke Sensor Included

Temperature Included

Flood Sensor Included

* Modifications according to customer’s requests are possible.

The RCAB-OD-2027 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations of active and passive telecom equipment.

Dual wall aluminum Robust design Modular design Easy installation

process Solid profile technology Excellent heat

dissipation 19” technology with

moving frames Cooling capacity by

using heat exchanger Customer specific

integrations Left and Right Type

available, depending on the installation site

1641

80

1481

1383 1440,77

546

638,63

448 507,74

Page 12: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

12 | M o d u l a r C o o l i n g S o l u t i o n s

886

292 146

380

965

103,50

roof-mounteddoor-mounted

RHEX-9790Heat Exchanger for Outdoor Cabinet

Technical Specifications*

Heat ExchangerSupply Voltage Nominal -48 VDC

Power Consumption (max) 77W

Current (max) 1.6A

Operating Temperature Range -33ºC to +60ºC

Cooling Capacity 40W/K

IP Rating (Cabinet Installation) IP 55

Speed 3050 min-1

Technical Features Control input 0-10 VDC/PWM, tach output

Housing Material Aluminum 1.5mm

Mounting Position Roof / Door

Fan Speed ControllerMounting Position Cabinet / Heat Exchanger housing

Programmable Fan Speed Control Included

Fan Alarm Included

* Modifications according to customer's requests are possible.

Raycap’s Heat Exchanger solutions ensure that active electronic equipment installed in outdoor cabinets are cooled properly, are isolated from dust and dirt and keep the noise level low.They provide excellent thermal performance, optimized controlling and have low maintenance requirements.

Hot Air

Hot Air

Cold Air

Cold Air

Exte

rnal

Air

Flow

door-mounted con�guration

roof-mounted con�guration

External Air Flow

Internal Air Flow

Internal Air Flow

HexCore

HexCore

M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y

Page 13: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C o o l i n g S o l u t i o n s | 13

RHEX-2868Heat Exchanger for Outdoor Cabinet

Heat ExchangerSupply voltage nominal -48 VDC

Power consumption (max) 115W

Current (max) 2A

Operating Temperature range -25ºC to +70ºC

Cooling capacity max 61W/K (90% fan speed)

IP Rating (cabinet installation) IP54

Speed 3050 min-1

Noise Level min 35dB (A) - max 60 dB (A) @1m

Number of fans 2

Technical features Control input 0-10 VDC/PWM, tach output

EMC Interface Immunity EN 61000-4-1/4-2/4-3/4-4/4-5/4-6/4-8

EMC Interface Emission EN 55022

Housing Material Aluminum 2mm

Safety EN 60950

Specification TA Lärm

Mounting Position Roof / Door

Dimensions 854mm (H) x 140mm (W) x 347mm (D)

Fan Speed ControllerMounting position Cabinet / Heat Exchanger housing

Programmable fan speed control Included

Fan Failure Alarm Included

Temperature Alarm Included

* Modifications according to customer’s requests are possible

.

Technical Specifications*

Active equipment is very sensitive and needs to be protected against external

environmental influences especially when installed outdoors. The Heat Exchangers are the perfect solutions to control the internal temperature of the cabinets and protect the active equipment from extreme external conditions.

The Heat Exchangers incorporate two fans creating separate internal and external air circuits. The outside air cannot infiltrate inside the cabinet and vice versa. The Heat Exchanger provides a lot of features such as reliability, excellent thermal performance, optimized controlling and low maintenance requirements.

Hot Air

Hot Air

Cold Air

Cold Air

Exte

rnal

Air

Flow

door-mounted con�guration

roof-mounted con�guration

External Air Flow

Internal Air Flow

Internal Air Flow

HexCore

HexCore

854

347

312

842

180

4x6

40

2

140

800

TOLERANCES DESCRIPTION

THIRD ANGLE PROJECTION

Heat Exchanger, Rooftop, DT street cab.

Page 14: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s
Page 15: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

M o d u l a r C a b i n e t S o l u t i o n s | 15

Page 16: Custom Telecom Cabinet Solutions · 2019-04-05 · custom product design and site surveys, as well as warehousing, logistics, customer training, and much more. About Raycap The company’s

© 2017 Raycap All rights reserved.G09-00-105 170515raycap.com � [email protected]

Raycap Worldwide Locations

Raycap GmbH Parkring 11 85748 Garching Munich Germany

Raycap S.A. Telou & Petroutsou 14 15124 Maroussi Athens Greece

Raycap S.A. Manufacturing Industrial Area of Drama 66100 Drama Greece

Raycap Inc. 806 South Clearwater Loop Post Falls, ID 83854 United States of America

Raycap Corporation SRL Soseaua de Centura 27-28 077040 Chiajna Ilfov Romania

Raycap Cyprus Ltd. 46 Lefkosias Street Industrial Area of Dali 2540 Nicosia Cyprus

Iskra Zaščite d.o.o. Stegne 23 A 1000 Ljubljana Slovenia

Raycap (Suzhou) Co. Ltd. Block B, Phase II of New Sea Union No. 58 Heshun Road SIP, Suzhou 215122 Jiangsu Province China