M o d u l a r C a b i n e t S o l u t i o n s | 1
Custom Telecom Cabinet Solutions
Whatever you want to say here.
M o d u l a r C a b i n e t S o l u t i o n s | 3
Raycap is a privately-held technology solu-tions provider offering products and services that support and protect the world’s critical telecommunications, energy, transportation and other infrastructure.
Since 1987 Raycap has built a worldwide organization with offices and production facilities throughout Europe and in North America. The company combines advanced engineering, superior product design, sys-tems integration and manufacturing capabil-ity with a deep understanding of the needs of the customer to create unique technologi-cal solutions for mission-critical applications. It also offers engineering services such as custom product design and site surveys, as well as warehousing, logistics, customer training, and much more.
About Raycap
The company’s comprehensive understand-ing of customer needs and the industries in which they operate is crucial to its ability to develop effective products and solutions that integrate the latest technology with the highest quality of service.
The Raycap team of talented, highly expe-rienced staff works together with customers to find the best-fit solutions. As a result, more than half of the products delivered are custom-built for unique customer ap-plications and to their specifications. From rigorous internal and independent testing to a consultative customer-focused approach, Raycap is determined to deliver the high-est quality products with responsiveness, innovation and agility.
M o d u l a r C a b i n e t S o l u t i o n s | 3
4 | M o d u l a r C a b i n e t S o l u t i o n s
RCAB-OD-9367 Outdoor Cabinet for Active Equipment
M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y
The RCAB-OD-9367 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations over existing cross connect cabinets in parallel with the hosting of active and passive telecom equipment.
Dual wall aluminum Robust design Modular design Easy installation
process Solid profile technology Excellent heat
dissipation 19” technology with
moving frames Cooling capacity by
using heat exchanger Customer specific
integrations Left and Right Type
available, depending on the installation site
1595
1652
1690
AA
126
1 9
0
480
575
80
539,5
EnvironmentalProtection Class IP55
Impact Protection IK10
Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)
Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
Earthquake Zone 4
MechanicalConstruction Aluminum alloy
Surface Powder coated, RAL 7035
Dimensions 1430mm (H) x 1652mm (W) x 540mm (D)
Reserved for PSU with DC Distribution 1U 19" (extra 1U for DC terminals)
Reserved for ODF 1U
Reserved for AC PDU 3U
Free User Space 10U 19"
Locking Mechanism 3-point system
Cable Entry Point Bottom
Temperature ControlCooling System Heat exchanger 60W/K
Heater Included
SensorsDoor Alarm Contact Included
Smoke Sensor Included
Temperature Included
Flood Sensor Included
* Modifications according to customer's requests are possible.
Environmental & Mechanical Specifications*
M o d u l a r C a b i n e t S o l u t i o n s | 5
RCAB-OD-6849 Outdoor Cabinet for Active Equipment
The RCAB-OD-6849 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. Due to its small dimensions, the cabinet is the ideal solution for installations in residential areas.
Dual wall aluminum Robust design Modular design Easy installation
process Solid profile technology Excellent heat
dissipation 19” technology with
moving frames Cooling capacity by
using heat exchanger Customer specific
integrations 1198,2
1188
BB
AA
444
180
1
333
8,7
429,5
Environmental & Mechanical Specifications*
EnvironmentalProtection Class IP55
Impact Protection IK10
Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)
Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
Earthquake Zone 4
MechanicalConstruction Aluminum alloy
Surface Powder coated, RAL 7035
Dimensions 1520mm (H) x 1188mm (W) x 430mm (D)
Reserved for PSU with DC Distribution 1U 19" (extra 1U for DC terminals)
Reserved for ODF 1U
Reserved for AC PDU 3U
Free User Space 10U 19"
Locking Mechanism 3-point system
Cable Entry Point Bottom
Temperature ControlCooling System Heat exchanger 60W/K
Heater Included
SensorsDoor Alarm Contact Included
Smoke Sensor Included
Temperature Included
Flood Sensor Included
* Modifications according to customer's requests are possible.
6 | M o d u l a r C a b i n e t S o l u t i o n s
RCAB-OD-7474 MFG 12 Outdoor Cabinet for Active & Passive Equipment
RCAB-OD-7474 is a modular double-wall multifunctional cabinet that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet with cooling technology is installed outdoors and due to its small dimensions the cabinet is the ideal solution for installations in residential areas.
Dual wall aluminum Robust design 100% Modular design Cabinet parts are
replaceable without service interruption
Excellent passive heat conductivity
Cooling system including heat exchanger
Customer specific integrations
500
M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y
Environmental & Mechanical Specifications*
EnvironmentalProtection Class IP54
Operating Temperature -33ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 )
Storage Temperature -33ºC to +45ºC (according to ETSI 300 019-1-1, Class 1.3)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
Resistance Class EN 1627:2011,RC2
MechanicalConstruction Aluminum
Surface Powder coated, RAL 7035
Dimensions 1400mm (H) x 1450mm (W) x 500mm (D)
Racks 2xETSI Racks 38SU, 3-bay system mountable in ETSI Rack
Locking Mechanism 3-point system
Cable Entry 1x splitted cable entry plate with 12 grommets
Doors 2 with door stopper
1x Swivel handle**
Plinth Magnelis, 4 adjustable leveling feet
Plastics High recyclable, halogen free
Specification TS0273/96
Temperature ControlCooling System Heat exchanger
SensorsTemperature Included
* Modifications according to customer's requests are possible.
** Locking mechanism available upon request.
M o d u l a r C a b i n e t S o l u t i o n s | 7
RCAB-OD-8040 MFG 15Outdoor Cabinet for Active & Passive Equipment
1700
145
0
500
Environmental & Mechanical Specifications*
EnvironmentalProtection Class IP54
Resistance Class RC2
Operating Temperature -33ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1)
Storage Temperature -33ºC to +45ºC (according to ETSI 300 019-1-1, Class 1.3)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
MechanicalConstruction Aluminum
Surface Powder coated, RAL 7035
Racks 1x19"/ETSI 38 SU, 1xTelecom rack
Locking Mechanism 3-point locking system
Doors 2 with door stopper
1x Swivel handle**
Cable Entry 1x Universal foam in MDF area,
1x Splitted cable entry plate with grommet in ETSI rack area
Dimensions 1700mm (H) x 1450mm (W) x 500mm (D)
Plinth Stainless steel, 4 adjustable leveling feet
Plastics High recyclable, halogen free
Temperature ControlCooling System Heat exchanger
SensorsTemperature Sensor Included
* Modifications according to customer's requests are possible.
** Locking mechanism available upon request.
RCAB-OD-8040 is a modular double-wall multifunctional cabinet that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet with cooling technology is the ideal solution for installations over existing cross connect cabinets in parallel with the hosting of active and passive telecom equipment.
Double wall aluminum Robust design 100% modular design Cabinet parts are
replaceable without service interrruption
Excellent passive heat conductivity
Cooling system including heat exchanger
Customer specific integrations
Left and right type available
8 | M o d u l a r C a b i n e t S o l u t i o n s
RCAB-OD-5306 MFG 18Outdoor Cabinet for Active & Passive Equipment
2000
160
0
500
Environmental & Mechanical Specifications*
EnvironmentalProtection Class IP54
Resistance Class EN 1627:2011, RC2
Operating Temperature -33ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1)
Storage Temperature -33ºC to +45ºC (according to ETSI 300 019-1-1, Class 1.3)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
MechanicalConstruction Aluminum
Surface Powder coated, RAL 7035
Racks MFG10 18 : 3xETSI 38SU, 3-bay system mountable in ETSI Rack
MFG10 18Ü : 1xETSI 38SU, 1x triple telecom rack
Locking Mechanism 3-point locking system
Doors 2 with door stopper
1x Swivel handle**
Cable Entry MFG10 18 : 1xSplitted cable entry plate with 18 grommets
MFG10 18Ü : 1xUniversal foam in the MDF area, 1xSplitted cable
entry plate with grommets in the ETSI rack area, 1xSplitted cable
entry plate with grommets in the telecom rack area
Dimensions 2000mm (H) x 1600mm (W) x 500mm (D)
Plinth Magnelis, 4 adjustable leveling feet
Plastics High recyclable, halogen free
Specification TS0273/96
Temperature ControlCooling System 2xHeat exchanger
SensorsTemperature Sensor Included
* Modifications according to customer's requests are possible.
** Locking mechanism available upon request.
RCAB-OD-5306 is a modular double-wall multifunctional cabinet that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet with cooling technology is installed outdoors and is the ideal solution for hosting demanding and sensitive active and passive equipment.
Double wall aluminum Robust design 100% modular design Cabinet parts are
replaceable without service interrruption
Excellent passive heat conductivity
Cooling system including heat exchanger
Customer specific integrations
Left and right type available
M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y
M o d u l a r C a b i n e t S o l u t i o n s | 9
RCAB-OD-1657 Outdoor Cabinet for Active Equipment
Environmental & Mechanical Specifications*
The RCAB-OD-1657 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations hosting active and passive telecom equipment.
Dual wall aluminum Robust design Modular design Easy installation
process Solid profile technology Excellent heat
dissipation 19" technology with
moving frames Cooling capacity by
using heat exchanger Customer specific
integrations
732
790
592
650
8095
1120
EnvironmentalProtection Class IP55
Impact Protection IK10
Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)
Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
Earthquake Zone 4
MechanicalConstruction Double Aluminum alloy
Surface Powder coated, RAL 7035
Dimensions 1295mm (H) x 790mm (W) x 650mm (D)
Reserved for PSU with DC Distribution 1U 19"
DC to AC Inverter 400W Included
AC PDU Included
MDF Space for 20x10 LSA PLUS, 2x64 Splitter Modules
Free User Space 6U 19"
Locking Mechanism 3-point system
Cable Entry Point Bottom
Temperature ControlCooling System Heat exchanger
Heater Included
SensorsDoor Alarm Contact Included
Smoke Sensor Included
Temperature Included
Flood Sensor Included
* Modifications according to customer's requests are possible.
10 | M o d u l a r C a b i n e t S o l u t i o n s
RCAB-OD-1171Outdoor Cabinet for Active Equipment
Environmental & Mechanical Specifications*
The RCAB-OD-1171 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations of active & passive telecom equipment.
Dual wall aluminum Robust design Modular design Easy installation
process Solid profile technology Excellent heat
dissipation ETSI technology with
moving frames Cooling capacity by
using heat exchanger Customer specific
integrations Left and Right Type
available, depending on the installation site
EnvironmentalProtection Class IP55
Impact Protection IK10
Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)
Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
Earthquake Zone 4
MechanicalConstruction Double Aluminum alloy
Surface Powder coated, RAL 7035
Dimensions 1503mm (H) x 1720mm (W) x 637mm (D)
Reserved for PSU with DC Distribution 5U
Reserved for ODF 1U
Reserved for AC PDU 3U
Free User Space 2x24U ETSI Rack
Locking Mechanism 3-point system
Cable Entry Point Bottom
Temperature ControlCooling System Heat exchanger
Heater Included
SensorsDoor Alarm Contact Included
Smoke Sensor Included
Temperature Included
Flood Sensor Included
* Modifications according to customer's requests are possible.
1677
1720
1770
916
.5
637
80
132
3 1
00
594
637
80
637
142
3
594
637
406
.5
M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y
M o d u l a r C a b i n e t S o l u t i o n s | 11
RCAB-OD-2027 Outdoor Cabinet for Active Equipment
Environmental & Mechanical Specifications*
EnvironmentalProtection Class IP55
Impact Protection IK10
Operating Temperature -45ºC to +45ºC (according to ETSI 300 019-1-4, Class 4.1 E)
Storage Temperature -25ºC to +55ºC (according to ETSI 300 019-1-1, Class 1.2)
Transportation Temperature -40ºC to +70°C (according to ETSI 300 019-1-2, Class 2.3)
Earthquake Zone 4
MechanicalConstruction Double Aluminum alloy
Surface Powder coated, RAL 7035
Dimensions 1640mm (H) x 1480mm (W) x 546mm (D)
Reserved for PSU with DC Distribution 2U 19"
Reserved for ODF 1U
Reserved for AC PDU 3U
Free User Space 10U 19"
Locking Mechanism 3-point system
Cable Entry Point Bottom
Temperature ControlCooling System Heat exchanger
Heater Included
SensorsDoor Alarm Contact Included
Smoke Sensor Included
Temperature Included
Flood Sensor Included
* Modifications according to customer’s requests are possible.
The RCAB-OD-2027 is an outdoor cabinet system that provides maximum protection of customer’s equipment against vandalism and extreme weather conditions. This cabinet is the ideal solution for installations of active and passive telecom equipment.
Dual wall aluminum Robust design Modular design Easy installation
process Solid profile technology Excellent heat
dissipation 19” technology with
moving frames Cooling capacity by
using heat exchanger Customer specific
integrations Left and Right Type
available, depending on the installation site
1641
80
1481
1383 1440,77
546
638,63
448 507,74
12 | M o d u l a r C o o l i n g S o l u t i o n s
886
292 146
380
965
103,50
roof-mounteddoor-mounted
RHEX-9790Heat Exchanger for Outdoor Cabinet
Technical Specifications*
Heat ExchangerSupply Voltage Nominal -48 VDC
Power Consumption (max) 77W
Current (max) 1.6A
Operating Temperature Range -33ºC to +60ºC
Cooling Capacity 40W/K
IP Rating (Cabinet Installation) IP 55
Speed 3050 min-1
Technical Features Control input 0-10 VDC/PWM, tach output
Housing Material Aluminum 1.5mm
Mounting Position Roof / Door
Fan Speed ControllerMounting Position Cabinet / Heat Exchanger housing
Programmable Fan Speed Control Included
Fan Alarm Included
* Modifications according to customer's requests are possible.
Raycap’s Heat Exchanger solutions ensure that active electronic equipment installed in outdoor cabinets are cooled properly, are isolated from dust and dirt and keep the noise level low.They provide excellent thermal performance, optimized controlling and have low maintenance requirements.
Hot Air
Hot Air
Cold Air
Cold Air
Exte
rnal
Air
Flow
door-mounted con�guration
roof-mounted con�guration
External Air Flow
Internal Air Flow
Internal Air Flow
HexCore
HexCore
M O D U L A R D E S I G N F O R M A X I M U M F L E X I B I L I T Y
M o d u l a r C o o l i n g S o l u t i o n s | 13
RHEX-2868Heat Exchanger for Outdoor Cabinet
Heat ExchangerSupply voltage nominal -48 VDC
Power consumption (max) 115W
Current (max) 2A
Operating Temperature range -25ºC to +70ºC
Cooling capacity max 61W/K (90% fan speed)
IP Rating (cabinet installation) IP54
Speed 3050 min-1
Noise Level min 35dB (A) - max 60 dB (A) @1m
Number of fans 2
Technical features Control input 0-10 VDC/PWM, tach output
EMC Interface Immunity EN 61000-4-1/4-2/4-3/4-4/4-5/4-6/4-8
EMC Interface Emission EN 55022
Housing Material Aluminum 2mm
Safety EN 60950
Specification TA Lärm
Mounting Position Roof / Door
Dimensions 854mm (H) x 140mm (W) x 347mm (D)
Fan Speed ControllerMounting position Cabinet / Heat Exchanger housing
Programmable fan speed control Included
Fan Failure Alarm Included
Temperature Alarm Included
* Modifications according to customer’s requests are possible
.
Technical Specifications*
Active equipment is very sensitive and needs to be protected against external
environmental influences especially when installed outdoors. The Heat Exchangers are the perfect solutions to control the internal temperature of the cabinets and protect the active equipment from extreme external conditions.
The Heat Exchangers incorporate two fans creating separate internal and external air circuits. The outside air cannot infiltrate inside the cabinet and vice versa. The Heat Exchanger provides a lot of features such as reliability, excellent thermal performance, optimized controlling and low maintenance requirements.
Hot Air
Hot Air
Cold Air
Cold Air
Exte
rnal
Air
Flow
door-mounted con�guration
roof-mounted con�guration
External Air Flow
Internal Air Flow
Internal Air Flow
HexCore
HexCore
854
347
312
842
180
4x6
40
2
140
800
TOLERANCES DESCRIPTION
THIRD ANGLE PROJECTION
Heat Exchanger, Rooftop, DT street cab.
M o d u l a r C a b i n e t S o l u t i o n s | 15
© 2017 Raycap All rights reserved.G09-00-105 170515raycap.com � [email protected]
Raycap Worldwide Locations
Raycap GmbH Parkring 11 85748 Garching Munich Germany
Raycap S.A. Telou & Petroutsou 14 15124 Maroussi Athens Greece
Raycap S.A. Manufacturing Industrial Area of Drama 66100 Drama Greece
Raycap Inc. 806 South Clearwater Loop Post Falls, ID 83854 United States of America
Raycap Corporation SRL Soseaua de Centura 27-28 077040 Chiajna Ilfov Romania
Raycap Cyprus Ltd. 46 Lefkosias Street Industrial Area of Dali 2540 Nicosia Cyprus
Iskra Zaščite d.o.o. Stegne 23 A 1000 Ljubljana Slovenia
Raycap (Suzhou) Co. Ltd. Block B, Phase II of New Sea Union No. 58 Heshun Road SIP, Suzhou 215122 Jiangsu Province China