1
maintenance walkway single ply roofing membrane photovoltaic solar panels to proposed canopy roof ETFE rooflights to entrance lobby ETFE rooflights to central open space maintenance walkway white painted polyester powder coated fascia green roof lower green roof primary canopy roof access safety balustrade set back from roof edge to reduce visual impact safety balustrade set back from roof edge to reduce visual impact Roof over second floor store room / access to roof level single ply membrane roof Secondary roof access Revision Notes: R04 - Roof over lift and Faith room extended R05 - First floor added over block 2 R06 - Access hatch added in roof over Plant room. R04 R05 R06 19 m² faith room TF.01 19 m² TfGM manager TF.04 22 m² TfGM comms. room TF.05 39 m² mixed driver's rest TF.06 11 m² Stagecoach paying in TF.12 11 m² Stagecoach manager TF.09 41 m² TfGM plant room TF.13 4 m² male acc. WC TF.08 49 m² tenant plant room TF.15 35 m² corridor TF.03 25 m² Stagecoach supervisor TF.11 4 m² female acc. WC TF.07 4 m² wc TF.10 12 m² stair 2 TF.16 lift lower green roof canopy over concourse canopy over concourse canopy over concourse canopy over front entrance access to lower roof from first floor level Revision Notes: R01 - External walls enclosing lift and faith room extended. R02 - Internal layout amended. R03 - First Floor level added. R02 R01 R03 Drawings and models powered by Austin-Smith:Lord LLP BIM using AutoDesk Revit Austin-Smith:Lord LLP Architects Designers Planners Landscape Architects Port Of Liverpool Building Pier Head, Liverpool L3 1BY t +44 (0)151 227 1083 . e [email protected] DO NOT SCALE. Use figured dimensions only. The contractor is requested to check all dimensions before the work is put in hand. ©All copyrights Austin-Smith:Lord LLP This drawing must only be used for the purpose for which it is supplied and its contents must not be reproduced for any purpose without written permission. No areas indicated, or areas calculated from this drawing should be used for valuation purposes or as the basis for development contracts. Austin-Smith:Lord LLP is a limited liability partnership registered in England & Wales. Number OC315362 Project Description Job No. Drawing No. Revision Date Drawn Scale @ A1 Status R PLANNING C 1 : 200 Transport for Greater Manchester - Tameside Interchange Proposed First Floor & Canopy Level Plans 914285 L(--)202 LL 10/06/2015 Revision Description By Chkd By Date * First Floor - General design development with topographical survey LL KGF 15/07/17 A First Floor - Planning LL KGF 15/10/19 B First Floor - Planning Submission LL KGF 15/11/25 C Re-issued to Planning following RIBA Stage 4 KGF LL 16/05/26 First Floor Plan Roof Plan

C:UserskalgillfaciDocuments914285 Ashton Bus Station ...plandocs.tameside.gov.uk/anitepublicdocs/00224266.pdf · Austin-Smith:Lord LLP BIM using AutoDesk Revit Austin-Smith:Lord LLP

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C:UserskalgillfaciDocuments914285 Ashton Bus Station ...plandocs.tameside.gov.uk/anitepublicdocs/00224266.pdf · Austin-Smith:Lord LLP BIM using AutoDesk Revit Austin-Smith:Lord LLP

maintenance walkway

single ply roofingmembrane

photovoltaic solar panelsto proposed canopy roof

ETFE rooflights toentrance lobby

ETFE rooflights tocentral open space

maintenance walkway

white painted polyesterpowder coated fascia

green roof

lowergreen roof

primary canopy roofaccess

safety balustrade setback from roof edge toreduce visual impact

safety balustrade setback from roof edge toreduce visual impact

Roof over secondfloor store room /access to roof level

single ply membraneroof

Secondary roof access

Revision Notes:R04 - Roof over lift and Faith roomextendedR05 - First floor added over block 2R06 - Access hatch added in roof overPlant room.

R04

R05

R06

19 m²faith room

TF.01

19 m²TfGM manager

TF.04

22 m²TfGM comms. room

TF.0539 m²

mixed driver's restTF.06

11 m²Stagecoach paying in

TF.12

11 m²Stagecoach manager

TF.09

41 m²TfGM plant room

TF.13

4 m²male acc. WC

TF.08

49 m²tenant plant room

TF.15

35 m²corridorTF.03

25 m²Stagecoach supervisor

TF.11

4 m²female acc. WC

TF.07

4 m²wc

TF.10

12 m²stair 2TF.16

lift

lowergreen roof

canopy overconcourse

canopy overconcourse

canopy overconcourse

canopy over frontentrance

access to lower rooffrom first floor level

Revision Notes:R01 - External walls enclosing lift andfaith room extended.R02 - Internal layout amended.R03 - First Floor level added.

R02

R01

R03

Drawings and models powered byAustin-Smith:Lord LLP BIM using AutoDesk Revit

Austin-Smith:Lord LLPArchitects Designers PlannersLandscape ArchitectsPort Of Liverpool BuildingPier Head, LiverpoolL3 1BYt +44 (0)151 227 1083.e [email protected]

DO NOT SCALE. Use figured dimensions only.The contractor is requested to check alldimensions before the work is put in hand.©All copyrights Austin-Smith:Lord LLP

This drawing must only be used for the purposefor which it is supplied and its contents must notbe reproduced for any purpose without writtenpermission.No areas indicated, or areas calculated from thisdrawing should be used for valuation purposesor as the basis for development contracts.Austin-Smith:Lord LLP is a limited liabilitypartnership registered in England & Wales.Number OC315362

Project

Description

Job No. Drawing No. Revision

Date

Drawn

Scale @ A1

Status

R

PLANNING C

1 : 200

Transport for Greater Manchester - Tameside Interchange

Proposed First Floor & Canopy Level Plans

914285 L(--)202

LL

10/06/2015

Revision Description By Chkd By Date

* First Floor - General design development with topographicalsurvey

LL KGF 15/07/17

A First Floor - Planning LL KGF 15/10/19B First Floor - Planning Submission LL KGF 15/11/25C Re-issued to Planning following RIBA Stage 4 KGF LL 16/05/26

First Floor Plan

Roof Plan