Cummins / Newage Range - 11 to 3300kVA
Advanced Diesel Engineering Ltd. utilise technologies
which reduce the primary pollutants in the exhaust of
a diesel generator set by approximately 80 percent.
Pollutants such as nitrogen oxides (NOx), hydrocarbons
(HC) and particulate matter (PM) from diesel engines are
precursors to smog and ozone in many populated areas
of the world. All our emissions-reduction technologies
are accomplished through in-cylinder design improvements
and precise control of the combustion process.
New technologies to reduce emissions
We are committed to meeting or exceeding clean air standards worldwide.
Low-Emissions Technologies
Advanced Diesel Engineering lead the industry in the
development of cleaner, quieter and more efficient
diesel-powered generator sets. We are committed to
meeting or exceeding all global air quality regulatory
standards for stationary and none-road diesel-engine
generator sets through 2017 and beyond. This protects
public health and conserves vital natural resources.
Developing products for a cleaner tomorrow
Global Strength, Local Partnership
With nearly 20 years experience in power generation, we can match the right generating,transfer and control technologies with your power needs – be it continuous, prime, peaking,standby, cogeneration or a complete turnkey power plant.
What makes us different?
ADE Ltd. Power Generation
is about more than innovative
technologies meeting your
needs. The key is our people,
who live by a simple set of
rules we call “The Three R’s”.
Relationships
At ADE Ltd. you are in touch
with real people you can
trust and rely on. Wherever
and whenever you need us,
we’ll be there for you.
Reliability
When you need real power
you can depend on us to
deliver unrivalled reliability.
We do what we say we
will and more. We keep
our promises.
Responsiveness
We aim to provide same-day
answers, turnkey solutions,
quick delivery, split-second
start-up and alongside our
tailored service agreements,
a phone that is answered 24
hours a day, 7 days a week.
Fully integrated power systems
Advanced Diesel Engineering Ltd, are leaders in the design
and manufacture of pre-integrated generator sets, ranging
from 8 to 3,300 kVA.
Most of our generator components – engine, alternator,
transfer switches and control systems – are designed and
manufactured by Cummins CPG in the UK. Each element is
designed to work in harmony from the start.
Wherever possible our diesel generator sets meet US EPA
emissions standards and are European EU stage II compliant.
Models with optional sound-attenuated enclosures meet
or exceed EU noise regulation 2000/14/EC Step 2006.
We are ISO 9001:2008 certified.
Our renowned international manufacture and export, sales and
service facilities are well established and we guarantee a close
business relationship wherever our products are operating, providing
you with fast access to reliable service, engineering expertise and
parts support.
Integrated design and manufacturing combine to give you unequalled reliability,power quality, rated performance and efficient operation.
Diesel Generator Sets
Delivering rugged, reliable mechanical and electrical
performance, our diesel generator sets are also suited
to utility peaking plants, distributed generation facilities,
peak shaving (or peak lopping) and power management
at large commercial or industrial sites.
Diesel-powered generator sets remain the best-value
choice worldwide for standby and emergency power
systems. Powered by heavy-duty Cummins engines,
our fuel-efficient generator sets are available in sizes
ranging from 8 to 3300 kVA and are known for their
responsive transient performance. Cooling systems
provide guaranteed performance in high ambient
temperatures.
High-performance, low-reactance Cummins
manufactured alternators provide good voltage
waveform and exceptional motor starting in demanding
applications such as data centres, hospitals and
industrial facilities.
Our generator sets are controlled by the world’s first
fully integrated microprocessor-based control system.
This seamlessly integrates governing, voltage
regulation, generator set control and protection
functions to provide:
• Rapid product availability
• Proven reliability and low life-cycle costs
• High efficiency and operational flexibility
• High-quality electrical performance
• Well-established service and fuel supply infrastructure
PowerCommand® InPowerTM for planned maintenance/service capability
PowerCommand® InPower™ for planned maintenance
and service provides both local and remote set-up and
diagnostics. The PC-based software allows a technician
to “talk to” a remote PowerCommand® system, determine
its status and make adjustments. An internet browser
interface provides easy access to PowerCommand®
InPower’s™ useful functions.
• Strip charts – Obtain real-life recordings of changing
conditions and performance
• Adjustments – Change system operating parameters
• Monitoring functions – Use real-time monitoring and data
recording to simplify testing and diagnostics
• Report generation – Automatically record test data
and formats for quick test reporting
• Fault simulations – Simulate warning & shutdown
conditions
C220 D5
QSK60
C33 D5
X Series Generator Sets
The latest addition to the Cummins Power Generation range, these compact, rugged newgenerator sets provide the ideal prime or standby power solutions for small businesses,telecoms companies or agriculture.
Best in their class, X Series generator sets are lightweight,
easy to service and deliver cost-effective, reliable power
from 8 kVA to 38 kVA @ 50 Hz and 7.5 kW to 35 kW
@ 60 Hz.
Several alternator sizes offer selectable motor starting
capacity. PowerCommand 1.1 electronic control comes
as standard to provide total system integration.
The X Series range is designed to meet ISO 8528
regulations. Optional sound-attenuated enclosures
optimise generator set cooling performance. Service points
are easily accessible and operators have plenty of room
for maintenance. In addition, X Series sets offer 500 hour
oil change intervals using 15W40 premium Blue Ch4
grade oil.
The walls of the enclosures are insulated to provide quiet
operation and comply with the 75 dB(A) at 1 MTR at 75%
load sound levels. This ensures the lowest possible noise
levels without compromising performance.
As with all Cummins Power Generation generator sets,
the X3.3 engine-powered X Series generator sets are
supported by a comprehensive warranty and worldwide
distributor network.
C11 D5
Please contact us for up to date information on the X series generator.
Sound attenuated enclosures from Advanced Diesel Engineering meet even the most strictsound requirements and provide protection from inclement weather.
The highly skilled ADE installation team can deliver, install, test and
• On site bulk fuel storage tanks
• High rise fuel pump & emergency dump systems
• Double walled pipe work
• Long run exhausts with noise damping systems
• Electrical distribution
• Building management system integration for
Plant Room Installations
On site installation and complete plant room solutions.
warning alarms, fuel and security notifications
• Acoustic treatment for reflective surfaces
• Air flow ducts, louvres and acoustic baffles
commission plant room installations, including:
• Combined Heat and Power (CHP) systems
Internet Service Provider - Stand by generator
Synchronised Cummins generators - Stand by system
• Project management
• Site management
• M & E design and installation
• Commissioning
• Logistics
Generator Projects
ADE’s Projects Department offersa comprehensive service to customers.
The Projects team incorporate all individual requirements
requested by the customer.
Services:
• Preventative maintenance
• Repairs and refurbishment
We offer a full range of servies from initial advice at the
feasibility and proposal stages, through to project
handover and lifetime support.
• Diesel & Gas generator installations
Data centre stand by power installation by ADE Ltd.
External radiator
50Hz Open Generators - 10 to 3300kVA
Integrated design and manufacturing combine to give you unequalled reliability,power quality, rated performance and efficient operation.
706 4047 x 1608
825 4266 x 1879
825 4047 x 1608
900 4266 x 1879
1041 4297 x 1685
1110 4571 x 1702
1400 5105 x 2000
1675 5690 x 2033
1675 5690 x 2033
2063 6175 x 2286
2250 6175 x 2286
2500 6175 x 2494
2750 5450 x 2251
C700 D5
C825 D5
C825 D5A
C900 D5
C1000 D5
C1100 D5
C1400 D5
C1675 D5
C1675 D5A
C2000 D5
C2250 D5
C2500 D5A
C2750 D5
C3000 D5 3000 7178 x 2254
5665
6528
6040
6680
6141
7374
10075
10626
10626
15152
15510
17217
25390
25390
Power output 50 Hz
StandbykVA50Hz
Model
565
660
660
720
833
888
1120
1340
1340
1650
1800
2000
2200
2400
StandbykW
50Hz
640
750
750
820
939
1000
1250
1400
1500
1875
2000
2250
2500
2750
PrimekVA50Hz
512
600
600
656
751
800
1000
1120
1200
1500
1600
1800
2000
2200
PrimekW
50Hz
4g
Emissions50Hz
Open SetDimensions(mm) L x W
Wet Weight(kg)
Alternator
VTA28G5
QSK23G3
VTA28G6
QSK23G3
QST30G3
QST30G4
KTA50G3
KTA50G8
KTA50GS8
QSK60G3
QSK60G4
QSK60G8
QSK78G9
QSK78G6
EngineType
ES17 D5 16.5 13 15 1305 x 680 554 X1.7G1
ES22 D5 22 18 20 1400 x 680 636 X2.5G1
ES28 D5 27.5 22 25 1515 x 680
12
16
20 651 X2.5G2
Power output 50 Hz
Power output 50 Hz
StandbykVA50Hz
Model StandbykW
50Hz
PrimekVA50Hz
PrimekW
50Hz
Open SetDimensions(mm) L x W
Wet Weight(kg)
Alternator EngineType
Model Tank(L)
C11 D5
C15 D5
C22 D5 107
C33 D5e 107
C38 D5e 107
C44 D5e 107
C55 D5e 107
C80 D5 107
C110 D5 107
C150 D5 310
C150 D5e 513
C175 D5e 513
C200 D5e 513
C220 D5e 513
C250 D5 376
C275 D5 569
C300 D5 569
C330 D5 569
C350 D5
C400 D5 674
C440 D5 674
C500 D5 811
C550 D5
StandbykVA50Hz
11
15
22
33
38
44
55
80
110
150
150
175
200
220
250
275
300
330
350
400
440
500
550
StandbykW
50Hz
8.8
12
17.6
26.4
30.4
35.2
44
64
88
120
120
140
160
176
200
220
240
264
280
320
352
400
440
PrimekVA50Hz
10
13
20
30
35
40
50
72
100
136
136
158
182
200
227
250
275
300
320
360
400
450
500
PrimekW
50Hz
8
10.4
16
24
28
31.68
40
58
80
109
109
126
146
160
182
200
220
240
256
288
320
360
400
Emissions50Hz
EU SII
EU SII
EU SII
EU SII
4g
EU SIIIA
EU SIIIA
EU SIIIA
EU SIIIA
4g
4g
4g
4g
EU SII
EU SII
EngineType
D1703-BG
D1703-BG
4B3.3G1
4BT3.3G3
4BT3.3G3
4BT3.3G3
4BT3.3G3
4BTA3.9G4
4-ISBeGI
6BTA5.9G2
QSB7G5
QSB7G5
QSB7G5
QSB7G5
6CTAA8.3G2
QSL.9G5
QSL.9G5
QSL.9G5
NT855G6
NTA855G4
NTA855G7
QSX15G8
QSX15G8 811
Open SetDimensions(mm) L x W
1300 x 720
1300 x 720
1753 x 930
1753 x 930
1753 x 930
1753 x 930
1753 x 930
1950 x 1046
1977 x 1046
2404 x 1100
2656 x 1000
2656 x 1000
2656 x 1000
2656 x 1000
2686 x 1300
3135 x 1100
3135 x 1100
3135 x 1100
3594 x 1100
3594 x 1100
3594 x 1100
3433 x 1500
3433 x 1500
Alternator
BC164B
BC164D
BC184E
BC184G
BC184H
UCI224D
UC224F
UC274C
UC274E
UCI274E
UCI274F
UC274H
UC274H
UCD274J
UC274K
HC4D
HC4D
HC4E
HC4F
HC5C
HC5C
HC5D
Wet Weight(kg)
376
385
609
645
705
776
776
1050
1200
1206
2027
2128
2226
2226
2000
2347
2570
2570
3386
3563
3683
4022
4220
FuelConsumption
Standby *
FuelCons.Prime **
FuelConsumption
Standby*
FuelCons.Prime**
FuelConsumption
Standby*
FuelCons.Prime**
* Litres Per Hour at 110% Load ** Litres Per Hour at 75% load
Fuel consumption shown in litres per hour * 110% Load ** 75% load
Fuel consumption shown in litres per hour * 110% Load ** 75% load
4
6
6.9
9.5
9.5
12.5
18.9
27
29.8
34.7
37
39
42
45.8
50
55
61.6
72
81.4
90.2
3.6
5.4
6.2
8.4
8.4
12
17
23
25.7
30
34
37
38.9
38.3
42
46
57
62
71.5
78.7
55.7 52
2.4 2.1
1.8 1.6
114
126.4
121
134
149.5
164.2
221
252.9
270
292
368
TBC
TBC
104
115.5
110
121
139
151
199
222
240
267
336
TBC
TBC
327.8 291
TBC
TBC
TBC
TBC
TBC
TBC
569
Utilising the latest 3D realisation software we design and manufacture specialist
bespoke canopies and acoustic containers:
• Super silencing
• Synchronised & parallel operation with
multiple generators
• Ruggedised portable enclosures for
extreme site conditions
Bespoke Enclosures
Bespoke acoustic packaging to meet the most demanding criteria.
• Modified ISO containers
• Large scale drop-over canopies
• Low vibration enclosures for high rise installations
• Internal double skin steel fuel tanks
• External bulk fuel storage with duplex pump
options for filling local/internal fuel tank
Containerised 14MW synchronised power plant
2500kVA generator in silenced drop-over canopy
Air tight, stainless steel, fire proof pumping station enclosure
Super-Silenced 450kVA Generator enclosure, c/w
vertical acoustic, air inlet/outlet system
500kVA, zintec steel generator canopy
silenced to 60dB(A) @ 1 metre
* @ 75% load unless otherwise stated
** @ 100% load
(x) - X Series product
Standard Enclosed Sets 50Hz
Please refer to our website at for up to date stock levels and special offer prices on our Cummins
generator range.
By following the link on our website you can also join our mailing list to receive advance news of any offers before they
are posted online.
www.adeltd.co.uk
Standard enclosed generators up to 550kVA.
Model Dimensions(mm) L x W x H
Wet Weight(kg)
LWA Tank(L)
Sound LevelsdBA @ 1m* dBA @ 7m*
StandbykVA50Hz
C11 D5 1454 x 769 x 1417 8811 638 72 62
C15 D5 1454 x 769 x 1417 8815 647 72 62
ES17 D5 1850 x 900 x 1375 9616.5 819 80** 63**
C22 D5 2244 x 969 x 1375 9422 933 10777 67
ES22 D5 1850 x 900 x 1375 9622 871 80** 63**
ES28 D5 1850 x 900 x 1375 9627.5 896 80** 63**
C33 D5 (X) 2242 x 967 x 1513 9633 1235 75 65
C38 D5(X) 2242 x 967 x 1513 9638 1270 75 65
C38 D5e 2244 x 969 x 1575 9438 1029 10777 67
C44 D5e 2245 x 969 x 1575 9444 1029 10777 67
C55 D5e 2244 x 969 x 1575 9455 1100 10777 67
C80 D5 2280 x 1084 x 1478 9480 1690 10777 67
C110 D5 2343 x 1084 x 1478 98110 1840 10781 71
C150 D5 2920 x 1136 x 1710 96150 2102 31076 67
C150 D5e 3900 x 1100 x 2062 97150 2947 51377 69
C175 D5e 3900 x 1100 x 2062 97175 3108 51377 69
C200 D5e 3900 x 1100 x 2062 97200 3206 51377 69
C220 D5e 3900 x 1100 x 2062 97220 3206 51377 69
C250 D5 3581 x 1360 x 2170 96250 3296 37676 68
C275 D5 4254 x 1424 x 2215 97275 3924 56977 69
C300 D5 4254 x 1424 x 2215 97300 4147 56977 69
C330 D5 4254 x 1424 x 2215 97330 4147 56977 69
C350 D5 5110 x 1563 x 2447 98350 4798 76 69
C400 D5 5110 x 1563 x 2447 98400 4975 67476 69
5110 x 1563 x 2447 98C440 D5 440 5095 67476 69
C500 D5 5110 x 1563 x 2447 99500 5672 81178 71
C550 D5 550 5110 x 1563 x 2447 1005776 81179 72
C33 D5e 2244 x 969 x 1575 9433 1029 10777 67 C11 D5
C220 D5
Power Generation Suppot Team
ADE Power Generation Support Team provide specialist advice
technical support and assistance for:
• Generator Service Enquiries
• Maintenance (Planned and Unplanned)
• 24 / 7 Service and Repair - Contracted Customers
• Parts and Consumables
• Customer Service Contracts
• New Equipment Sales
Service
Our aim is to provide customers with world class service support that
is fast and responsive, flexible and convenient, and minimises equipment
downtime and costs.
We offer a range of services including
• Maintenance Scheduling - specifically designed to meet the service
• Rapid Response - 24 hour emergency call out as required
• General Servicing - all major makes and models of generator supported
Local Support on your Doorstep
With a national fleet of mobile service engineers, our highly trained
and skilled power generation service professionals have the capability,
expertise and experience to support you, wherever you may be.
Service Agreement
Each service agreement is tailor made to your specific requirements.
Once the optimised schedule of activities has been established,
our engineers will visit you via a pre-arranged appointment to undertake
the required servicing. A service agreement including regular testing,
preventative maintenance, routine servicing and optional oil sampling
will ensure that your generator continues to provide you with the vital
power you need.
For a quotation for a maintenance agreement or to arrange
contact our Power Generation Support Team who will be happy to assist.
Tel: 01977 658 100 - Email: [email protected]
Parts
For specialist advice and assistance on all products and to place your
order for next day delivery on genuine Cummins parts and engine
consumables (including specialist coolant - with extended drain
interval, oil and filters), contct our National Parts Team.
Tel: 01977 658 100 - Email: [email protected]
Nationwide Service & Support
ADE Ltd. provide comprehensive nationwidesupport on all generators across the UK.
needs of your business
Automatic transfer switches
Power Transfer Equipment
PowerCommand automatic transfer switches optimise performance and simplifyoperation and service.
Direct connection with the generator set controller offers
more reliable and smoother communication with the
entire system.
GTEC series transfer switches covering the range
40 to 1250 amps, with 1600 and 2000 amp available
from Q2 2009 - provide normal and generator set
source monitoring, generator set starting, and load
transfer functions for emergency, standby and optional
standby applications.
GTEC transfer switches are continuously rated, so they
can be applied in applications up to their nameplate
rating. The transfer switch power contacts are silver alloy
composition with high-pressure design that can withstand
thousands of switching cycles without burning, pitting or
welding. They require no routine contact maintenance
and provide 100% continuous current ratings.
The transfer switch control is reliable and easy to
understand, utilising LED lamps for status indications,
and push-button controls for operator functions.
The control is field-programmable without the use
of service tools.
Paralleling systems
Demonstrated reliability
PowerCommand paralleling systems are designed around
dedicated-purpose controllers that are prototype-tested for
reliability and performance.
PowerCommand paralleling systems deliver the flexibility
demanded by your complex applications. We use
common control blocks with prototype-tested components.
These systems deliver the features and performance you
require and are supported by the industry’s only local
paralleling service organisation.
Integrated paralleling in the generator set controls
offers fast synchronising. Any number of generator sets
can be synchronised in less than 15 seconds in most
applications. PowerCommand paralleling systems give you
demonstrated reliability:
• Distributed logic designs that isolate issues
by eliminating single points of failure
• Prototype testing to validate system design
• Innovative failure mode effect analysis
• Industry-leading mean time before failure (MTBF) data
• View displays of current alarms as well as alarm logs
• Set three levels of system security
• Fully customise the monitoring an control system
• Monitor up to 60 devices at a site
• Remotely monitor up to 200 sites
Software and Networking
PowerCommand software and networking tools let you easily manage on-site and off-sitepower systems from one location.
Whether you’re using a desktop computer, a laptop
or a mobile phone, PowerCommand iWatch™
and PowerCommand Pulse™ help you reduce power
set-up time and maintenance.
PowerCommand Pulse for multiple power systems
PowerCommand Pulse is a full SCADA package.
Its enhanced graphical user interface quickly and easily
monitors multiple power systems.
PowerCommand Pulse features let you:
• Communicate via an ethernet connection, phone line
• Connect via an internet browser on a remote PC
• Send alarms to mobile phones, pagers
• Display voltage and frequency of each source
• Monitor one or two generator sets and up to four transfer
• Monitor up to 30 generator sets and transfer switches
PowerCommand iWatch for reliable
internet-based monitoring
PowerCommand iWatch™ lets you monitor generator
set and transfer switch functions via the internet.
PowerCommand iWatch™ features let you:
or available wireless configuration
or e-mail addresses
switches (PowerCommand iWatch™ 100)
(PowerCommand iWatch™ 200)
Case Study
Cummins equipment utilised for dieselgenerator stand by power system at newstate-of-the-art hospital.
Equipment: Integrated 6 MVA Prime rated gen-sets providing
a standby power system with three individually controlled
Cummins Power Generation (C2250 D5) generator sets,
and a DMC 300 digital master control system.
Purpose: To deliver reliable emergency back up power for
the new state of the art Hospital in the event of a utility outage.
Covering a surface area of 95,383 square metres, the health-
care campus houses 612 beds and state-of-the-art facilities
including a high-tech diagnostics unit, an emergency care
centre, and a new mental health unit operated by the local
trust.
Continuous and reliable power is critical to the successful
treatment of patients at the new hospital, the NHS Foundation
Trust procured an emergency standby system to supply back-
up power to the hospital and health campus in the event of a
mains power outage.
Three 2000 kVA Prime rated, Model: C2250 D5
generator sets were installed which are 60 Litre V16
turbocharged QSK60-G4 engines, with fuel day tanks
fitted with a ‘double knock’ safety system to prevent
and minimise any spillages. Also supplied were air inlet
and discharge systems, exhaust gas silencers and flue
runs for the safe dispersal of emissions, fuel supply system
which included day tanks, pipe-work, leak detection
and fire wire monitoring.
Digital Master Control for simple
and autonomous operation
Each of the generator sets feature an on-board
synchroniser and controller, able to operate independently
from one another. When linked to the user-friendly touch
screen DMC 300 digital master control, that has been
configured specifically for new Edith Cavell Hospital,
allows the rapid paralleling of the mains supply and
generators, load management and the recording of data.
Uninterrupted power for critical operations
In the event of an electricity supply failure, power is
automatically restored to critical systems within 15 seconds
fulfilling C44 Hospital Specification. The digital master
control has been programmed to allow the first generator
to come on-line, and energise the whole 11 kV ring whilst
the remaining two units are synchronising with the first set.
The DMC 300 digital master control fitted with a “hot PLC
standby system” to eliminate a complete equipment failure
minimising any problems with the primary PLC.
PowerCommand controls give you reliable, cost-effective solutions to integrateddigital paralleling.
Generator sets from Advanced Diesel Engineering are
available with industry-leading PowerCommand controls.
Standard features include not only integrated digital
governing and voltage regulation, but also analogue
MainFeatures
General
AVR
Electronic Governing
Glow plug control
Cycle cranking
Full authority engine control
Networking (LonWorks)
Networking (ModBus)
Fault history
Operator Interface
Manual start/stop
Auto/remote start
Exercise function
Auto LED
Not in Auto LED
Manual LED
Common Shutdown LED
Common Warning LED
Exercise LED
Fail to Start LED
Emergency stop (local and remote)
Alphanumeric screen
Remote start input active LED
Fault reset
Measurement & Instrumentation
Oil Pressure
Oil Temperature
Water Temperature
Engine Speed
Hours Run
Number of Starts
Battery Voltage
Exhaust Temperature
Measurement & Instrumentation
3 Phase L-L & L-N Voltage & Frequency
3 Phase Current
kWh
Total kVA
Total kW & kVAr
PF
Per Phase kVAr, kW
Per Phase kVA
Shutdown Protection & Indication
Low Fuel Level
High Fuel Level
Low Oil Pressure
High Engine Coolant temperature
Failure to Crank Shutdown
Over Crank (Failure to Start)
Overspeed
PCC1301/PowerCommand 1.1
Generator controls
PowerCommand/PCC
- - -
- - - -
- - - -
- - - -
- - - -
- -
- - -
- -
- - -
- -
- - -
- - -
- - - -
PowerCommand 1.2
- - -
- - -
-
-
-
-
and digital metering, digital engine monitoring systems,
smart-starting systems, battery monitoring systems,
AmpSentry™ true alternator protection and more.
MainFeatures
Shutdown Protection & Indication
Under & Over Voltage
Under & Over Frequency
Over Current
Earth Leakage
Reverse Power
Reverse VAr
Threshold Warning Indicators
Low Oil Pressure
Low Engine Coolant Temperature
High Engine Coolant Temperature
Low Coolant Level
Low Battery Voltage
High Battery Voltage
Batt. Alt. Charge Fault
Over Current
Over Load
Paralleling Capability
Auto Synchronising (Isolated Bus)
kW & VAr Load Sharing Control
Auto Synchronising (Utility Bus)
Base Load (Utility Bus)
Synchroscope
Peak Lopping
Power Transfer Function
Open Transition Transfer
Hard Closed Transition
Soft Closed Transition (ramping)
Transfer & Base Load (Utility)
Gen/Mains Breaker Control
Gen/Mains Breaker Status Protection
Environment
Operating Temp. Range -40 C to +70 C° °
OperatingTemp.User Interface -20°C to +70°C
Humidity up to 95% (none condensing)
Codes & Standards
CE Compliant
NFPA110
UL508 Listed
UL Certified
Controller Inputs/Outputs
Relay Outputs
Configurable Input/Output
PCC3201
Digital Inputs (shutdown, warning or status)
Option Standard
PCC2100 with optional Bargraph fitted
- Not Available
Generator controls
PowerCommand/PCC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
2
N/A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
4
PowerCommand 3.3
N/A
-
-
-
-
-
-
-
-
-
4
4
N/A
-
-
-
4
4
2
4
Standard Gen-set
Applicable for supplying power to varying electrical
load for the duration of power interruption of a reliable
utility source. Emergency Stand by Power (ESP)
is in accordance with ISO 8528. Fuel Stop power
in accordance with ISO 3046, AS 2789, DIN 6271
and BS 5514.
Limited-Time Running Power (LTP):
Applicable for supplying power to a constant electrical
load for limited hours. Limited Time Running Power (LTP)
is in accordance with ISO 8528.
Prime Power (PRP):
Applicable for supplying power to varying electrical load
for unlimited hours. Prime Power (PRP) is in accordance
with ISO 8528. Ten percent overload capability is
available in accordance with ISO 3046, AS 2789,
DIN 6271 and BS 5514.
Base Load (Continuous) Power (COP)
Applicable for supplying power continuously to a constant
electrical load for unlimited hours. Continuous Power
(COP) in accordance with ISO 8528, ISO 3046, AS 2789,
DIN 6271 and BS 5514.
For comprehensive conditions of application including
COP and LTP, please refer to factory.
This document lists the main specifications and options
of the gen-set. For other customer specified
requirements, please contact us to discuss your
needs.
Standard O Optional x Not Available• (1) C22 D5 has only PCC 1301 control available
2) C150 D5e has only PowerCommand 1.1 control available
Emergency Stand-by Power (ESP):
Specifcations and Options
C22-C55
(B3.3) C11-C15
4 Stroke water cooled Diesel engine Kubota Cummins Mechanical governing • • Electronical governing O O Standard air flter • • Heavy Duty air flter O O Water jacket heater 220/240 v O O Radiator for 40°C ambient temperature x x Radiator for 50°C ambient temperature • • Radiator for 55°C ambient temperature x x Antifreeze 25/75 (Ethylene glycol) • • Antifreeze 50/50 (Ethylene glycol) O O Delivered without coolant O O Fan and belt guards • • Core guards • • Alternator single bearing T° = class H. Isol. = class H • • Alternator heater O O High humidity isolation O O Paralleling CT’s + 3 function governor x x Exciter voltage regulator – PMG 3 phase sensing x x PCC 1301 • • (1) PCC 2100 x x PCC 3100 x x PCC 3201 x x PowerCommand 1.1 x • (1) PowerCommand 1.2 x x PowerCommand 3.3 x x Alternator mounted (rear side) x x Alternator mounted (right side from engine) x x Alternator mounted (left side from engine) x x Pedestal side mounted (left side from alternator) x x Pedestal end mounted x x Pedestal side mounted (right side from alternator) • • CE compliance x x CSA/NRTL/C compliance • • 3 pole Main Circuit Breaker O O 4 pole Main Circuit Breaker • • Base Frame with AVM • • Handling by 2 fork slots integrated x x 4 direction handing by pallet jack and fork slots • • 4 eyes for lifting • • Manual handbook multi language (Eng/Fre/Spa) • • Manual handbook, specify language O O 2 years warranty for standby application, 1 year for Prime • • 5 years extension warranty for Standby application O O 2 years warranty – Prime power 6,000 hours O O 10 years major components x x Packing export box O O Delivered in Munsell Green under plastic shrinked • • Oil tap • • Oil sump pump x x Attenuation industrial silencer delivered loose • • Attenuation industrial silencer not delivered O O Attenuation residential silencer delivered loose O O Attenuation critical silencer x x Silencer extension O O Silencer fexible O O Stainless bellows x x Heat shields on open sets • • Starter and charge alternator • • Starting batteries with cables and bracket • • Starting batteries and bracket not delivered, cables last O O Large fuel tank integrated in the base frame (PVC type) x x Large fuel tank integrated in the base frame (metal type) x x Large fuel tank integrated in the base frame (welded) • • Fluid catchment • • Secondary containment x O Fuel automatic make up x x Fuel pre-flter/water separator • • 500 litres free-standing fuel tank delivered loose x x Silent Power canopy O O Delivered in Munsell Green under plastic shrinked • • Special colour in replacement of Munsell Green O O Modular structure in bolted sheet metal • • Complete process with degreasing before powder coating • • Fitting with seal to prevent water ingression • • Numbers of point lift 1 1 Fixed window for control panel • • External emergency stop button • • Residential silencer integrated to the canopy • • Number of doors with Single key latches 3 4 PowerBox model (see speci�c information on page 11) x x CSC approval for shipment x x Residential silencer integrated to the container x x Floor x x Access doors x x Weather louver air outlet x x 24 volts light with timer x x Emergency light and security fuel shut off valve x x Lighting/European standard outlets 220V x x Fuel tank 500 litres x x Fuel tank none x x Fuel tank 500 litres, with �uid catchment x x Fuel tank, 2000 litres (not suitable for critical start) x x Fuel tank double wall, 4000 litres (not suitable for critical start) x x
En
gin
eR
adia
tor
Alt
ern
ato
rC
on
tro
l Pan
elG
ense
tO
ilS
ilen
cer
Bat
tery
Fu
elS
ilen
t E
ncl
osu
reS
ilen
t C
on
tain
er (
Po
wer
Bo
x)
Specificationsand Options
C70-C80(B3.9)
C100-C150(ISBe-B5.9)
C150-C220(QSB7)
C250(6C)
QSL
NT/NTA
QSX15
QSK23
VTA28 QST30
K38
KTA50
QSK60QSK78
Cummins Cummins Cummins Cummins Cummins Cummins Cummins Cummins Cummins Cummins Cummins Cummins
• x x x x x x x x x x xO • • • • • • • • • • •• • x • • • • • • •O O • O O O O O O O O OO O O O O O O O O O O Ox x x x x x x • • • • •• • • • • • • O O O O Ox x x x x x x x x x O x
• • • • • • • • • • • xO O O O O O O O O O O xO O O O O O O O O O O •• • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • • • •O O O O O O O O O O O OO O O O O O O O O O O Ox x x x x x O O O O O OO O O O O O O O • • • •• • x • • x x x x x x xO O x O x • • • x x • xx x x x x x x x • • O xx x x x x x O O x x x •x x • x x x x x x x x x x x • (2) x x x x x x x x xx x O (2) x x x x x x x x xx x x x • • x • • • • x
• • x • x x x x O O x xO O x O x x x x x x x xx x • x x x • x x x x •x x x x • • x x x x x xx x x x O O x x x x x x
• • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • O O O O OO O O O O O O O O O O O
• • • • • • • • • • • •• • O • x x x x x x x xx x x x x x x x x x x x
• • • • • • • • • • • •• • • • • • • x x x x xO O O O O O O • • • • •• • • • • • • • • • • •O O O O O O O O O O O OO O O O O O O O O O O Ox x x x x x x O O O O OO O O O O O O O O O O O
• • • • • • • • • • • •• • • • • • • • • • • •O O O O O O O O O O O O
• • • • • • • O O O O OO O O O O O O x x x x xO O O O O O O O O O O Ox x x x O O O O x x x xO O O O x x x x x x x xO O O O O O x x x x x xx x x x x x O O O O O O
• • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • O O O O OO O O O O O O x x x x x
• • x • x x x x x x x xO O x O x x x x x x x xx x • x • • • x x x x xx x • x O O O x x x x xx x O x O x x x x x x xx x O x O x x O O O O O
• • • • • • • • • • • •x x x x x x x O O O O OO O O O O O O x x x x x
• • • • • • • x x x x xO O O O O O O x x x x x
• • • • • • • x x x x x
• • • • • • • x x x x x
• • • • • • • x x x x xx x 2 2 2 2 2 x x x x x
• • • • • • • x x x x x
• • • • • • • x x x x x
• • • • • • • x x x x x4 4 4 4 4 4 4 x x x x xx x x x x x x x PB 20S PB 40S PB 40S PB40Xx x x x x x x x • • • •x x x x x x x x • • • •x x x x x x x x wood wood wood metalx x x x x x x x 2 2 2 5x x x x x x x x O O O •x x x x x x x x • • • •x x x x x x x x O O O Ox x x x x x x x O O O Ox x x x x x x x • • • •x x x x x x x x O O O Ox x x x x x x x x O O xx x x x x x x x x O O xx x x x x x x x x x x