Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
CTI CEtJTRE TE:;'lrJG l!HfRtlAT<ullAl
Test Report
Report No.: EED35K000208-1
Customer
Address
Access Lighting Corporation
14410 Myford Road, Irvine, CA 92606 USA
Description of the submitted sample(s):
Sample Name
Model/Type
Manufacturer
Brand
: LED Luminaire
: 20080LED/20082LED/20084LED
access
: 100-277 V AC, 50/60 Hz, 13 W, 3000 K
Page 1 of 9
Ratings
Test Item : Total Luminous Flux, Luminous Efficacy, Zonal Lumen Density, Luminous
Sample Quantity
Sample No.
State of Sample(s)
LED Driver Model
Sample Received Date
Sample Tested Date
Test Requested
Intensity Distribution and Electrical Parameters
: 1 pc
: 35K0208-01
: Normal
: RG-15W300/RG-15W300A/RG-15W300
: Sept. 21, 2018
: Sept. 25, 2018
: All test items were measured according to
IES LM-79-08 Electrical and Photometric Measurements of Solid-State
Lighting Products
Laboratory Note: The laboratory that conducted the testing items in this report has been accredited by the
National Voluntary Laboratory Accreditation Program (NVLAP LAB CODE: 200889-0), for IES LM-79 testing
of SSL products. And the report must not be used by the client to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government.
Reviewed by
CENTRE TESTING INTERNATIONAL CO
Approved by
Date
Supervisor/Vivian Wang
Sept. 27, 2018
Check No.: 2448716088
NO.1996, Xinjin qiao Road, Pudong New District,
Shanghai, 201206, China
CTI CWT- c TESWIG IIITERNATICilAl
Test Report
Report No.: EED35K000208-1
Equipment list:
Test Equipment
Goniophotometer
Standard Lamp
Digital Power Meter
1 Test Condition
Ambient Condition
Photometric Method
Tested
Stabilization Time
Equipment Model
GO-R5000
D908
WT210
Total Operation Time including Stabilization
2 Test Method
2.1 Requirements of Ambient Condition
Equipment No.
ATTEELSH00 105
ATTEELSH00106
BTTEELSZ 10093
: 25.2 ·c
: Goniophotometer
: 120 V AC, 60 Hz
: 30 minutes
: 70 minutes
Page 2 of9
Calibration Due Date
Jul. 08, 2019
Jul. 03, 2019
May 29, 2019
The ambient temperature in which measurements are being taken shall be maintained at 25 ·c ± 1 ·c, measured
at a point not more than 1 m from the SSL product and at the same height as the SSL product. Air flow around
the SSL product being tested should be such that normal convective air flow induced by device under test is not
affected.
2.2 Seasoning of SSL Product
For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no
seasoning was performed.
2.3 Stabilization of SSL Product
Before measurements are taken, the SSL product under test shall be operated long enough to reach stabilization
and temperature equilibrium. The time required for stabilization depends on the type of SSL products under test.
The stabilization time typically ranges from 30 minutes to 2 or more hours for SSL product. It can be judged
that stability is reached when the variation (maximum - minimum) of at least 3 readings of the light output and
electrical power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%.