    CSSR PS degradation due to Other Congestion

    (Huawei)

  • Page 2Nexwave Design and Strategic

    Main Problem

    Highlight : Site JAJARSOLOMW all sectors, have degradation of CSSR PS, follow by increments of Other Congestion

  • Page 3Nexwave Design and Strategic

    Analysis

    Highlight : JAJARSOLOMW located at RNC SOLO

    - XPU SRN=2,SN=2,SSN=1 XPU Load RNC SOLO

    SRN=2,SN=2,SSN=1 decreased on 12 Sept 2013,

    For this case on JAJARSOLOMW, If We compare XPU Load RNC SOLO SRN=2,SN=2,SSN=1 and Rejection due to Other Congestion at JAJARSOLOMW not in-line. Might be problem in NodeB board or other possibility

    RNC XPU Load

  • Page 4Nexwave Design and Strategic

    Analysis

    Highlight : Base on NodeB Board Configuration,

    JAJARSOLOMW have 2 WBBP. These 2 WBBP located at CN=0,SRN=0,SN=1 and CN=0,SRN=0,SN=3

    Base on CPU Board Load, we found unbalance CPU Board Load, CPU Board Load of WBBP CabinetNo=0,SubrackNo=0,SlotNo=3 reach 90%, and CPU Board Load of WBBP CabinetNo=0,SubrackNo=0,SlotNo=1 is 0%

    Proposed to rebalance CPU Board Load of WBBP

    NodeB Board Configuration

    CPU Board Load

  • Page 5Nexwave Design and Strategic

    Action

    Highlight : After check WBBP board

    CabinetNo=0,SubrackNo=0,SlotNo=1 already configured properly, check Board sharring status.

    Base on NodeB MML Command, We found ULGROUP for WBBP board CabinetNo=0,SubrackNo=0,SlotNo=1 not configured

    Proposed to add ULGROUP for WBBP board CabinetNo=0,SubrackNo=0,SlotNo=1

    Check UL Group at NodeB MML Command

  • Page 6Nexwave Design and Strategic

    Action

    Highlight : Base on NodeB MML Command, We

    found DLGROUP for WBBP board CabinetNo=0,SubrackNo=0,SlotNo=1 not configured

    Proposed to add DLGROUP for WBBP board CabinetNo=0,SubrackNo=0,SlotNo=1

    Check DL Group at NodeB MML Command

  • Page 7Nexwave Design and Strategic

    Result

    Highlight : CPU WBBP Board Load already

    balanced Rejection due to Other Congest

    already disappear and CSSR PS JAJARSOLOMW improved

  • Page 8Nexwave Design and Strategic

    Conclusion

    Conclusion Rejection due to Other Congest already disappear and CSSR PS JAJARSOLOMW

    improved after to rebalance CPU Board Load of WBBP.