4
© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314 Form Version: January 2013 CSI Form 1.5C SUBSTITUTION REQUEST (During the Bidding/Negotiating Stage) Project: To: Re: Substitution Request Number: From: Date: A/E Project Number: Contract For: Specification Title: Section: Page: Description: Article/Paragraph: Proposed Substitution: Address: ______________________________________ Phone: Manufacturer: Trade Name: Insulfoam/Insulroof Model No.: Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified. Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation. The Undersigned certifies: Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product. Same warranty will be furnished for proposed substitution as for specified product. Same maintenance service and source of replacement parts, as applicable, is available. Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule. Proposed substitution does not affect dimensions and functional clearances. Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution. Submitted by: Signed by: Firm: Address: Telephone: A/E’s REVIEW AND ACTION Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials. Signed by: Date: Supporting Data Attached: Drawings Product Data Samples Tests Reports Insulfoam

CSI Form 01-5C - Substitution Request - Insulfoam · CSI Form 1.5C SUBSTITUTION REQUEST ... Substitution approved ... Microsoft Word - CSI Form 01-5C - Substitution Request.docx

Embed Size (px)

Citation preview

Page 1: CSI Form 01-5C - Substitution Request - Insulfoam · CSI Form 1.5C SUBSTITUTION REQUEST ... Substitution approved ... Microsoft Word - CSI Form 01-5C - Substitution Request.docx

© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314

Page ___ of ___ Form Version: January 2013 CSI Form 1.5C

SUBSTITUTION REQUEST

(During the Bidding/Negotiating Stage)

Project:

To:

Re:

Substitution Request Number:

From:

Date:

A/E Project Number:

Contract For:

Specification Title:

Section: Page:

Description:

Article/Paragraph:

Proposed Substitution: Address: ______________________________________ Phone: Manufacturer:

Trade Name: Insulfoam/Insulroof Model No.:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies: • Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.• Same warranty will be furnished for proposed substitution as for specified product.• Same maintenance service and source of replacement parts, as applicable, is available.• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.• Proposed substitution does not affect dimensions and functional clearances.• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the

substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

A/E’s REVIEW AND ACTION

Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: Drawings Product Data Samples Tests Reports

Insulfoam

bear
Sticky Note
Marked set by bear
Page 2: CSI Form 01-5C - Substitution Request - Insulfoam · CSI Form 1.5C SUBSTITUTION REQUEST ... Substitution approved ... Microsoft Word - CSI Form 01-5C - Substitution Request.docx

 

Nationwide Manufacturing· Toll Free 800.248.5995 · www.Insulfoam.com

Re: Inclusion of InsulRoof SP roof insulation in your specification

Insulfoam, a division of Carlisle Construction Materials, submits for your approval a code-

approved equivalent roofing insulation alternative on the referenced project.

InsulRoof SP (InsulFoam SP) roof insulation, which comes with a factory-laminated

performance glass facer, meets the physical property requirements listed in your specification.

InsulRoof SP has numerous UL and FM code listings and is specifically designed for use in

mechanically-attached single-ply and other roof systems. Detailed code listings are available at

www.Insulfoam.com or can be provided upon request.

All Insulfoam insulations come with a fully-warranted stable R-value (our products are not

impacted by LTTR R-value reductions) and offer superior moisture resistance.

For your review, we are enclosing:

1. InsulRoof SP technical data sheet

2. Our 100% R-value Warranty for InsulRoof SP

With over 50 years of design experience, multiple manufacturing locations in the US, and

dedicated R&D centers that lead insulation and roofing research, Insulfoam has been supporting

architectural and design communities by offering some of the most effective roof insulation solutions.

We look forward to extending that value and support on the referenced project.

Please contact the undersigned, or visit www.Insulfoam.com for more information.

Sincerely,

Insulfoam

Page 3: CSI Form 01-5C - Substitution Request - Insulfoam · CSI Form 1.5C SUBSTITUTION REQUEST ... Substitution approved ... Microsoft Word - CSI Form 01-5C - Substitution Request.docx

Engineered EPSVersatile - Durable - Sustainable

Roofi ng Starts with Insulfoam

DescriptionInsulRoof SP (InsulFoam SP) is an engineered insulation consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS) with a durable and stable, factory-laminated coated glass facer. InsulRoof SP is available in a nominal density of 1lb/ft3 or 1.25lb/ft3, and meets or exceeds the requirements of ASTM C578, Standard Specifi cation for Rigid, Cellular Polystyrene Thermal Insulation. In addition, InsulRoof SP offers a long-term, stable R-value and has excellent dimensional stability, compressive strength and water resistance properties.

UsesInsulRoof SP is specifi cally designed for low-sloped roof applications that employ mechanically fastened or ballasted TPO, PVC and EPDM, as well as low-sloped built-up, modifi ed bitumen and fully adhered single-ply roofs that incorporate cover boards or slip sheets. InsulRoof is also designed for use in fully-adhered fl eeceback systems with compatable adhesives. Please consult local building codes and membrane manufacturers for system requirements.

Advantages ¡ Labor Savings. With a factory-laminated facer, InsulRoof

SP saves labor time and reduces overall project costs, when incorporated into a roofi ng system that would otherwise require a slip sheet.

¡ Code Approvals. Insulfoam insulations are recognized in the International Code Council Evaluation Service (ICC-ES), and have numerous Underwriters Laboratory and Factory Mutual Approvals. Please contact your local Insulfoam representative for details.

¡ Environmentally Friendly. It does not contain any ozone-depleting blowing agents, may contain recycled material, and is 100% recyclable if ever removed or replaced.

¡ Stable R-value. The product’s thermal properties will remain stable over its entire service life. There is no thermal drift, so the product is eligible for an Insulfoam 20-year thermal performance warranty.

¡ Proven Performance. EPS has been manufactured using the same chemistry since the mid-1950s, providing proven performance.

¡ Water Resistance. InsulRoof SP does not readily absorb moisture from the environment.

SizesInsulRoof SP is available in several standard thicknesses. Non-standard sizes may also be ordered; InsulRoof SP can be made up to a thickness of 6" (R-26), with a minimum thickness of 2" for 1 lb/ft3 insulation and 1.5" for 1.25 lb/ft3 insulation.

FIRE-RATED GLASS-FACED INSULATIONSP

Typical Physical Properties*

PropertyTest

MethodValue

Density (nom. pcf) ASTM C303 1.00 1.25

R-Value (Resistance) - per inch(hr•ft2•°F)/BTU

@ 25 °F@ 40 °F@ 75 °F

ASTM C518or

ASTM C1774.354.173.85

4.554.253.92

C-Value (Conductance) - per inchBTU/(hr•ft2•°F)

@ 25 °F@ 40 °F@ 75 °F

ASTM C518or

ASTM C1770.2300.2400.260

0.2200.2350.255

Compressive Strength (psi, 10% deformation)

ASTM D1621

10-14 13-18

Flexural Strength (min. psi) ASTM C203 25 30

Dimensional Stability (maximum %)

ASTM D2126

2.0 2.0

Water Vapor Permeance (max. perm., 1 inch)

ASTM E96 5.0 3.5

Water Absorption (max. % vol.) ASTM C272 4.0 3.0

*Properties are based on data provided by resin manufacturers, independent test agencies and Insulfoam.

Nationwide Manufacturing ¾ Toll Free: (800) 248-5995 ¾ www.Insulfoam.com3104 - (08/14)

Page 4: CSI Form 01-5C - Substitution Request - Insulfoam · CSI Form 1.5C SUBSTITUTION REQUEST ... Substitution approved ... Microsoft Word - CSI Form 01-5C - Substitution Request.docx

19727 57th Avenue East, Puyallup, WA 98375 • Toll Free: (800) 248-5995 • Fax: (253) 271-3265

www.Insulfoam.com

Owner’s Name: Building Name: Owner’s Address: Building Address:

Warranty Number: Warranty Effective Date:

Insulfoam. Insulfoam, a division of Carlisle Construction Materials Incorporated (“Insulfoam”) hereby warrants for a period of 20 years, commencing with the warranty effective date, that the InsulFoam SP thermal resistance (R-value) will meet or exceed the values stated below. If the product is determined by sampling and tests (conducted as provided below) to not meet the warranty values stated below, Insulfoam will, in its sole discretion, either deliver to the Owner a quantity of equivalent Insulfoam product to replace the non-performing Insulation or refund to the Owner the original purchase price of the non-performing Insulation. Insulfoam’s total liability over the life of this warranty shall not exceed the original purchase price of the insulation.

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND SHALL NOT BE EXTENDED OR ALTERED EXCEPT BY WRITTEN INSTRUMENT SIGNED BY INSULFOAM. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION SET FORTH IN THIS WARRANTY. INSULFOAM SPECIFICALLY DISCLAIMS LIABILITY FOR ANY DIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, INCLUDING, BUT NOT LIMITED TO, INCREMENTAL HEATING, COOLING OR SIMILAR COSTS, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW WHATSOEVER.

Conditions. Insulfoam’s obligations under this Warranty will only take effect if installed in strict accordance with all applicable Insulfoam specifications, recommendations and guidelines which were in effect at the time of installation. Originals or copies of invoices and bills showing the cost of the InsulFoam SP insulation shall be submitted along with any claims under this Warranty Agreement. Insulfoam’s failure at any time to enforce any terms or conditions stated herein shall not be construed to be a waiver of its right to enforce that term or condition.

Exclusions. This Warranty shall be void if, in Insulfoam’s judgment, the InsulFoam SP’s performance has been impaired by either damage or alterations (lacking prior Insulfoam written approval) to the product. Insulfoam does not warrant the compatibility of the InsulFoam SP with any other products including, but not limited to, any roofing or waterproofing membranes or coatings.

Insulation Testing. All sampling shall be conducted in accordance with sampling procedures prescribed by Insulfoam, and samples of the InsulFoam SP shall only be taken in the presence of an authorized Insulfoam representative. Testing of the InsulFoam SP samples shall be in accordance with ASTM Test Method C518 or the then closest Insulfoam-approved effective equivalent test method. InsulFoam SP samples shall be conditioned to equilibrium prior to testing. All sampling and testing costs (including but not limited to costs of InsulFoam SP uncovering, removal and replacement) shall be at the Owner’s sole expense.

Thermal Values. The InsulFoam SP product will have the following thermal resistance (R-value) on a per

inch basis:

InsulFoam SP 1.25 pcf R-value of 4.25 when tested at 40F R-value of 3.92 when tested at 75F

InsulFoam SP

20-Year Limited Thermal Warranty

R-value of 4.17 when tested at 40F R-value of 3.85 when tested at 75F InsulFoam SP 1.0 pcf